RS 88 Tech Data 2015

2016-06-06

: Guide Rs 88 Tech Data 2015 RS 88 Tech Data 2015 POLYUREAS Metzger manuals Niagara-Library

Open the PDF directly: View PDF PDF.
Page Count: 2

TEST METHOD RESULTS
HARDNESS, SHORE “A” @ 70˚F D-2240 A86-90
TENSILE STRENGTH D-638 970 PSI
TENSILE ELONGATION*(@ 70˚F) D-638 180%
ADHESION TO CONCRETE D-4541 350-400 PSI
TACK FREE @ 70˚F - 5 Minutes
TRAFFIC READY @ 70˚ F - 1 Hour
MIX RATIO (by vol.) - 1:1
SOLIDS CONTENT - 100%
SHRINKAGE - Negligible
* This property provided only for comparison with other polyureas.
Elongation is not an indication of expansion capability.
TECHNICAL DATA RS-1
USGBC LEED® EQ Credit 4.1 - Low Emitting Sealant
1. Product Name
SPAL-PRO RS 88
2. Manufacturer
METZGER/MCGUIRE
PO Box 2217 Concord, NH 03302 (USA) Phone: 603-224-6122
Fax: 603-224-6020 Web: www.metzgermcguire.com
3. Product Description
Composition
Spal-Pro RS 88 is a rapid setting polyurea polymer liquid
of 100% solids content. When cured, Spal-Pro RS 88 is a
gray, rubberlike solid with a hardness of Shore A86-90.
Basic Use
Spal-Pro RS 88 was developed to ll and protect joints in
trafcked industrial and retail concrete oors. Its primary
function is to support such trafc and protect joint edges.
Spal-Pro RS 88 is intended for use where nal temperatures
are from 32˚F (0˚C) to +120˚F (49˚C).
Other Uses
Spal-Pro RS 88 is also ideal for lling random cracks in
industrial oors.
4. Limitations
Spal-Pro RS 88 is not recommended for use under VCT or
other non-breathing ooring systems.
Spal-Pro RS 88 is designed for interior use and may not be
suitable for outdoor applications due to thermal movement.
Spal-Pro RS 88 may exhibit bubbling and/or compromised
adhesion if concrete or ambient moisture levels are excessive.
5. Advantages
Spal-Pro RS 88 is Rated “Heavy-Duty”
Unlike softer polyureas, Spal-Pro RS 88’s higher shore
hardness provides greater edge protection and support.
Spal-Pro RS 88 is “Rapid-Setting”
At 70˚F (21˚C) it can be opened to full trafc in as little
as (60) minutes and light trafc in (30) minutes.
Spal-Pro RS 88 is Colorfast
Spal-Pro RS 88 maintains a consistent color prole
and resists fading and other discoloration under normal
conditions.
Spal-Pro RS 88 is Non-Staining
In normal slab surface conditions, Spal-Pro RS 88 does
not exhibit residual concrete staining often associated with
semi-rigid llers.
Spal-Pro RS 88 is Ideal for Use in Stained/
Polished Floors
Spal-Pro RS 88 can be used to ll joints and cracks in
polished concrete oors, and will not smudge or smear
during grinding/polishing.
6. Correct Joint Design/Installation
Spal-Pro RS 88 should be installed full joint depth in saw-cut
contraction/control joints (or 2” minimum in saw-cut joints
exceeding 2” in depth) per PCA and ACI guidelines.
In construction (formed) joints that are not saw-cut, Spal-Pro
RS 88 should be installed at a minimum 2” depth. DO NOT
USE COMPRESSIBLE BACKER ROD IN STANDARD SAW
CUT CONTRACTION/CONTROL JOINTS! Rod may be used
2” down in construction joints or saw cut joints exceeding 2” in
depth ONLY.
7. Color, Packaging and Accessories
Standard color is Standard Gray, multiple ColorFast and custom
colors are also available. Available in 10 gallon (US) kits
(2-5 gallon US pails) and 600 ml (300:300) dual-cartridge
convenience kits. Optional FAST PACK is available to accelerate
initial gel/cure time.
8. Applicable Specications
There are no government or ASTM standards for industrial oor
joint llers. Spal-Pro RS 88 meets or exceeds the oor joint ller
guidelines set forth by the American Concrete Institute (302.1
R-04 Guide for Concrete Floor and Slab Construction), ACI 360
and Portland Cement Assoc. (Concrete Floors on Ground, Fourth
Edition 2008).
9. USDA/FDA/CFIA/LEED® Approval
Spal-Pro RS 88 is acceptable for use in USDA, FDA, and CFIA
regulated facilities. Spal-Pro RS 88 contains no VOC’s and is
fully compliant with USGBC LEED® green building standards.
Saw-Cut Contraction
(Control) Joint
2”
Backer
Rod
Fill to Depth
of Saw Cut
Non Saw-Cut, Thru-Slab
Construction (Cold) Joint
REVISED 09/15
Heavy-Duty Semi-Rigid Polyurea Joint Filler
for Class 5-9 Industrial Concrete Floors
Customer Service - (800) 223-MM80 - Technical Assistance
E-Mail: info@metzgermcguire.com • Web Site: www.metzgermcguire.com
10. TECHNICAL PROPERTIES
18. Safety
This product is for industrial use only. Use only in well ventilated areas.
Practice all normal jobsite safety precautions (clear work area, etc). Refer
to SDS and installation instructions for more information.
19. Food Related Facilities
Spal-Pro RS 88 is acceptable for use in facilities regulated by USDA/
FDA/CFIA. Contact us to discuss project details if contamination is a
concern.
20. Material Warranty
WARRANTY: Metzger/McGuire Co. solely and expressly warrants that its Spal-Pro RS 88 shall
be free from defects in material and workmanship for 365 days from the date of purchase. Unless
authorized in writing by an ofcer of Metzger/McGuire, no other representations or statements made
by Metzger/McGuire or its representatives, in writing or orally, shall alter this warranty. Metzger/
McGuire makes no warranties, implied or otherwise, as to the merchantability or tness for ordinary
or particular purposes of its products and excludes the same. If any Metzger/McGuire product fails
to conform with this warrant, Metzger/McGuire will replace the product at no cost to the purchaser.
Purchaser’s sole remedy in any case shall be limited to the purchase price or replacement cost of
product and specically excludes labor and the cost of labor, lost wages and opportunity costs, and
all other possible incidental, consequential or special damages resulting from any claim of breach
of warranty, breach of contract, negligence or any legal theory. Any warranty claim must be made
within one (1) year from the date of material purchase. Metzger/McGuire does not authorize anyone
on its behalf to make any written or oral statements which in any way alter the installation procedures
or written installation instructions published in its product literature or on its packaging labels. Any
installation of Metzger/McGuire products which fails to conform with such installation information or
instructions shall void this warranty. Purchaser shall be solely responsible for determining the suitability
of Metzger/McGuire’s products for the purchaser’s intended purpose.
11. Technical Assistance
Complete technical support and literature are available from authorized
distributors, through our web site (www.metzgermcguire.com) or by
contacting our New Hampshire headquarters at (800) 223-MM80.
12. Where to Specify and File
Spal-Pro RS 88 is exclusively for use in concrete oors and thus should
always be referenced in 03251 (expansion/contraction joints) & 03300
(cast-in-place concrete). It is not a sealant and should not be specied as
part of 07900, other than for cross reference.
13. Quality Installation Programs
Metzger/McGuire offers quality installation assurance programs for
qualied projects. Contact Metzger/McGuire for specic information.
14. Availability
Spal-Pro RS 88 is available through quality construction supply
distributors (listing at www.metzgermcguire.com) or through our NH
headquarters.
15. Installation
The following instructions are ABBREVIATED. Complete instructions are
provided with each shipment.
When to Install - The installation of Spal-Pro RS 88 should be deferred
as long as possible after slab placement, and should not be installed
prior to 30 days to ensure adequate adhesion. ACI recommends a slab
cure of 60-90 days or longer, to permit for greater concrete shrinkage/
joint opening, lessening the expected incidence of joint ller separation.
Ambient areas should be stabilized at nal operating temperature prior
to installation, refrigerated/frozen goods areas stabilized and held for an
additional 7-14 days or longer, if possible. Refer to Technical Bulletins T5
(Filler Installation Timing) and T6 (Filler Timing for Refrigerated Buildings)
for additional information.
Joint Preparation - Joints should be completely free of saw laitance, dirt,
debris, coatings/sealers and frost or visible moisture. Joint cleaning
procedures must accomplish the removal of all of the above. Failure to
do so will compromise adhesion. Simply “raking” debris out of joint is
not an acceptable cleaning method. Preferred methods of joint cleaning
include using a dustless concrete saw with diamond blade (ensure blade
is slightly wider than joint or clean both sides) or sandblasting. No primer
is needed. If unusual conditions are present, contact Metzger/McGuire.
Choking off the base of the joint is normally not required due to Spal-
Pro RS 88’s rapid set. Do not use compressible backer rod (Ethafoam,
etc) in saw cut joints less than 2” deep.
Prior to Dispensing - Thoroughly read SDS and complete installation
instructions prior to opening containers or attempting to dispense.
Spal-Pro RS 88 must be dispensed with dual-feed power dispensing
equipment, or with pre-lled, dual-dispense cartridge kits. Manual
dispensing is impractical due to short working life (1-2 minute gel time).
Power dispensing systems should be set to a 1:1 ratio by volume. If
installing in cooler temperatures, material should be maintained at a
minimum temperature of 75˚F (24˚C) for best results. We recommend
the use of a 1/2” diameter (ID) static mixer with 30 or 32 elements for
material dispensing and proper mix. We strongly recommend performing
periodic ratio checks on power dispense units to ensure proper cure.
Material provided in pails should be thoroughly mixed to redistribute any
settlement that may have occurred during shipping or storage. Cartridges
should be shaken aggressively to accomplish same.
Pump tanks, lines and dispensing manifold should be clean and free of
any residual materials remaining from previous ller installations.
15. Installation (continued)
Dispensing
Joints can be lled in one or two passes, depending upon joint depth and
dispensing tip used. Preferred method is to ll from bottom to top using a
dispensing tip that ts into the joint. Take care not to entrap air bubbles.
Slightly overll the joint, leaving a crowned prole, and allow to cure.
Finishing
The crown may be easily razored off as early as 15 minutes after
placement, depending upon temperature. We recommend testing various
shave times to nd the optimal shave, which results in a ller prole that
is ush with the oor’s surface and free of any lm from material overll.
If shave time is substantially delayed or if temperatures are low, RS 88
shaving process may be more labored. Should ller cure below the oor
surface (due to settlement into the void at base of joint, etc.), remove top
1/2” of ller and re-apply RS 88. Grinding/polishing operations should
be deferred for one hour or more after placement. If using FAST PACK
addition, 25-30 minutes or more.
Clean-Up
Spills of unmixed components can be cleaned up with solvent (MEK,
denatured alcohol, etc) or scraped/shaved off oor and tools if cured.
16. Maintenance
Once cured, Spal-Pro RS 88 is basically maintenance free. If joints
should open after installation, ll voids with additional Spal-Pro RS
88. Refer to Technical Bulletin T11 (Joint Filler Separation; Causes &
Corrections) for additional information.
Spal-Pro RS 88 Technical Data Sheet RS-1
Fax: 603-224-6020 • E-Mail: info@metzgermcguire.com • www.metzgermcguire.com
Joint Size (US) LF/Gal.
1/8" x
1
1/2" 100
1/8" x
13/4" 85
1/8" x
2" 75
3/16" x 3/4" 135
3/16" x
1" 100
3/16" x
11/4" 85
3/16" x
11/2" 70
3/16" x
13/4" 60
3/16" x 2" 50
1/4"
x 1" 80
1/4" x 11/4" 60
1/4" x 11/2" 50
1/4" x 13/4" 45
1/4" x 2" 40
Joint Size (Metric) M/Gal
3 x 38 30
3 x 44 26
3 x 50 23
5 x 19 41
5 x 25 30
5 x 31 26
5 x 38 21
5 x 44 18
5 x 50 15
6 x 25 24
6 x 31 18
6 x 44 14
6 x 50 12
9 x 25 15
15. Installation (continued)
Dispensing
Joints can be filled in one or two passes, depending upon joint depth and
dispensing tip used. Preferred method is to fill from bottom to top using
a dispensing tip that fits into the joint. Take care not to entrap air bubbles.
Slightly overfill the joint, leaving a crowned profile, and allow to cure.
Finishing
The crown may be easily razored off as early as 15 minutes after
placement, depending upon temperature. We recommend testing
various shave times to find the optimal shave which results in a filler
profile that is flush with the floor's surface and free of any film from
material overfill. If shave time is substantially delayed or if temperatures
are low, RS 88 shaving process may be more labored.
Should filler cure below the floor surface (due to settlement into the void
at base of joint, etc.), remove top 1/2" of filler and re-apply RS 88.
Grinding/polishing operations should be deferred for one hour or more
after placement. (If using Fast Pack addition, 25-30 minutes or more).
Clean-Up
Spills of unmixed components can be cleaned up with solvent (MEK,
denatured alcohol, etc) or scraped/shaved off floor and tools if cured.
16. Maintenance
Once cured, Spal-Pro RS 88 is basically maintenance free. If joints
should open after installation, fill voids with additional Spal-Pro RS 88.
Refer to Technical Bulletin T11 (Joint Filler Separation; Causes & Correction)
for additional information.
17. Approximate Coverage Rates
18. Safety
This product is for industrial use only. Use only in well ventilated areas.
Practice all normal jobsite safety precautions (clear work area, etc).
Refer to MSDS and installation instructions for more information.
19. Food Related Facilities
RS 88 is acceptable for use in facilities regulated by USDA/FDA/CFIA.
Contact us to discuss project details if contamination is a concern.
20. Material Warranty
WARRANTY: Metzger/McGuire Co. solely and expressly warrants that its Spal-Pro RS 88 shall be free from defects in
material and workmanship for 180 days from the date of purchase. Unless authorized in writing by an officer of Metzger/
McGuire, no other representations or statements made by Metzger/McGuire or its representatives, in writing or orally, shall
alter this warranty. Metzger/McGuire makes no warranties, implied or otherwise, as to the merchantability or fitness for
ordinary or particular purposes of its products and excludes the same. If any Metzger/McGuire product fails to conform
with this warrant, Metzger/McGuire will replace the product at no cost to the purchaser. Purchaser's sole remedy in any
case shall be limited to the purchase price or replacement cost of product and specifically excludes labor and the cost of
labor, lost wages and opportunity costs, and all other possible incidental, consequential or special damages resulting from
any claim of breach of warranty, breach of contract, negligence or any legal theory. Any warranty claim must be made
within one (1) year from the date of material purchase. Metzger/McGuire does not authorize anyone on its behalf to make
any written or oral statements which in any way alter the installation procedures or written installation instructions published
in its product literature or on its packaging labels. Any installation of Metzger/McGuire products which fails to conform with
such installation information or instructions shall void this warranty. Purchaser shall be solely responsible for determining
the suitability of Metzger/McGuire's products for the purchaser's intended purpose.
17. Approximate Coverage Chart
REVISED 09/15

Navigation menu