I. General Description  This  device  is  to  measure  heart  rate  and  being  composed  of  main  body  (wrist watch),  sensing  part,  gloves,  a  charging  adapter  and  a  software  (Optional).  Main body and the sensing part is connected to each other and can be  mounted  on  the glove. The  measurement  principle  is  based  on  the  optics.  The  amount  of  the  reflected light compared to the acting light is measured at the sensing part. The change of the light reflectance is thereafter analyzed to calculate heart rate at the main body(wrist watch). Calculated  pulses  are  displayed  on  the  LCD  screen  of  wrist  watch,  and  can  be wirelessly transmitted to other devices, PC or smart phone. This device uses a rechargeable battery and can be charged through DC adapter.   II. Component Description  1. Heart rate monitor
①   Main  body  (wrist  watch):  The  main  body  is  central  processing  part composed  of  LCD  display,  start-stop  button,  measurement  button, communications terminals and a built-in communication module.    Ⓐ  communication terminal: IN-OUT serial communication port Ⓑ  LCD display : LCD screen that displays various information. Ⓒ  "S" (Start / Stop) Button: power ON / OFF Ⓓ  "M" (Measurement) Button: Start measurement. ② Sensor  cable:  Connect  the  main  body  and  the  sensing  part  that  makes  it possible to transfer the information. ③ Gloves ④ Sensor mounts : a sensor fixation part ⑤ Wrist strap ⑥ Sensing  part  :  optical  parts  which  measures  PPG(Photo  plethysmography) signal. It measures the amount of  the reflected light compared  to  the  acting light at the finger
III. Using a heart rate monitor  1. Wearing and power-on the device  (1) Wearing heart rate monitor gloves   * Caution :     When  you  wear  gloves,  please  fasten  the  finger  strap  not  too  loose  after confirming that the sensing part is located on the root part of first joint of the index finger. The wrist strap (wrist fasteners) should be fasten tightly not to move around a wrist. (2) Press the ‘S(start)’ button : LCD is ON and displays the device ID and the current settings.      - The status of the monitor is marked as dot, '•', to the left of the display. The modes are ‘Set’, ‘Mode’ and ‘Com’. By default, '•' should appear at ‘Set’ and ‘Com’ at the same time.  2. Heart rate measurement  (1) In order to start the heart rate measurement, press "M (Measure On)" button.     * Measuring Notes     The  initial  10  seconds  are  needed  to  initialize  the  measurement,  it  is recommended  during  this  first  10  seconds  not  to  move  your  fingers  and  hands, and make your hands as if holding an egg lightly.
(2) If the 10 seconds initialization is successful, the heart rate monitor displays your current heart rate at the top of the LCD display.   *. Notice   In some cases (not usual), If it displays zero ‘0’ for a while, It is recommended to press the ‘M'(Measure Off) button to stop measuring  and restart  monitor  after re-worn the device.  (3) During exercise, any of the buttons should not be pressed.  3. After using the heart rate monitor.  (1) In order to terminate the heart rate measurement, press ‘S (Stop)’ button.   The heart rate monitor will turn off all display. After you wear off the gloves, please be kept charged by plugging in the adapter.  (2) Pressing ‘S(stop)’ button, If the monitor displays 'BUSY', you should not do any operation and let it terminate automatically.  4. How to store and maintenance  (1) Storage environment : Temperature -10~55  ℃, humidity is kept at less than 95%. (2) The following points should be taken when storing. ① not exposed to corrosive gases. ② should be kept away from moisture and dust.   ③ should be kept clean.  5. Precautions during use  (1) Ware the sensing part with care to avoid application of excessive force. (2) Remain stop during 10 to 20 seconds after pressing the ‘M(measure)’ button (3) Do not stare at the light of the sensing part since the LED light is harmful if you stare on.
(4)  This  device  was  developed  for  purposes  described  in  this  manual  and  the manufacturer is not responsible for side effects caused by an improper purpose or improper use. (5) Before using the device and accessory, please check and confirm that there is no faulty.  When  in  doubt,  do  not  use  and  notify  the  manufacturer  or  service  center immediately. (6)  This  device  should  be  repaired  by  an  approved  person  and  approved organizations. (7) This device should not be repaired by user itself. (8) Use only standardized accessories which is provided with this device.  IV. Electrical rating  (1) The type and degree of protection to protect against electrical shock :   The internal power-type equipment, BF-type mounting   (2) Electrical Rating: DC 3.7V Lithium polymer battery      V. Matters    (1) The product name, model name (model): heart rate monitor (HRM-1000)   (2) the manufacturer's name and address:    - Company Name : H3 System Co., Ltd.    - Address: 3rd floor, Daedeok Bldg., 397-27, Doryong-dong, Yuseong-gu,   Daejeon city, Korea (republic of)    - Phone : +81-42-862-9313~4    - Homepage : http://www.h3system.co.kr   (3) manufacturer’s authorization and manufacturing product license number    - Manufacturer’s authorization: listed after approval    - Manufacturing product license number: listed after approval   (4) The manufacture’s serial number, manufacturing date, weight, packaging unit    - manufacture’s serial number: listed after manufacture    - Date of Manufacture: listed after manufacture
   - Weight: 60g (excluding charging adapter)    - Packing: 1set   (5) How to use (including performance), and use precautions or warnings, Storage:     written at a separate attachment   (6) Purpose: To measure and display heart rate during exercise.   (7) Other necessary matters    ① The type and degree of protection to protect against electrical shock :   The internal power-type equipment, BF-type mounting   ②  Electrical Rating: DC 3.7V Lithium polymer battery     (8) This device is for medical equipment (in Korea).      ※  The  above  information  is  listed  on  the  back  of  the  device,  packaging  and attachments.
 Regulatory Statements to be included in the Users Guide for Sputnik  USA-Federal Communications Commission (FCC)  This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by tuning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:  -Reorient or relocate the receiving antenna -Increase the distance between the equipment and the receiver. -Connect the equipment to outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help.  Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.