H3 SYSTEM HRM-1000 Heart Rate Monitor User Manual User s Manual HRM 1000 x

H3 SYSTEM Co., Ltd. Heart Rate Monitor User s Manual HRM 1000 x

Users Manual

Download: H3 SYSTEM HRM-1000 Heart Rate Monitor User Manual User s Manual  HRM 1000 x
Mirror Download [FCC.gov]H3 SYSTEM HRM-1000 Heart Rate Monitor User Manual User s Manual  HRM 1000 x
Document ID1660199
Application IDxEhVFKTM2ZLGRzqCaPsN0w==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize34.69kB (433615 bits)
Date Submitted2012-03-20 00:00:00
Date Available2012-03-20 00:00:00
Creation Date2012-01-09 15:58:47
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2012-03-17 05:58:49
Document TitleMicrosoft Word - User's Manual _HRM-1000_.docx
Document CreatorPScript5.dll Version 5.2.2
Document Author: Guest

Heart Rate Monitor
(HRM-1000)
User’s Manual
H3 System Co., Ltd.
I. General Description
This device is to measure heart rate and being composed of main body (wrist
watch), sensing part, gloves, a charging adapter and a software (Optional). Main
body and the sensing part is connected to each other and can be mounted on the
glove.
The measurement principle is based on the optics. The amount of the reflected
light compared to the acting light is measured at the sensing part. The change of the
light reflectance is thereafter analyzed to calculate heart rate at the main body(wrist
watch).
Calculated pulses are displayed on the LCD screen of wrist watch, and can be
wirelessly transmitted to other devices, PC or smart phone.
This device uses a rechargeable battery and can be charged through DC adapter.
II. Component Description
1. Heart rate monitor
① Main body (wrist watch): The main body is central processing part
composed
of
LCD
display,
start-stop
button,
measurement
button,
communications terminals and a built-in communication module.
Ⓐ communication terminal: IN-OUT serial communication port
Ⓑ LCD display : LCD screen that displays various information.
Ⓒ "S" (Start / Stop) Button: power ON / OFF
Ⓓ "M" (Measurement) Button: Start measurement.
② Sensor cable: Connect the main body and the sensing part that makes it
possible to transfer the information.
③ Gloves
④ Sensor mounts : a sensor fixation part
⑤ Wrist strap
⑥ Sensing part : optical parts which measures PPG(Photo plethysmography)
signal. It measures the amount of the reflected light compared to the acting
light at the finger
III. Using a heart rate monitor
1. Wearing and power-on the device
(1) Wearing heart rate monitor gloves
* Caution :
When you wear gloves, please fasten the finger strap not too loose after
confirming that the sensing part is located on the root part of first joint of the index
finger. The wrist strap (wrist fasteners) should be fasten tightly not to move around
a wrist.
(2) Press the ‘S(start)’ button : LCD is ON and displays the device ID and the current
settings.
- The status of the monitor is marked as dot, '•', to the left of the display. The modes
are ‘Set’, ‘Mode’ and ‘Com’. By default, '•' should appear at ‘Set’ and ‘Com’ at the
same time.
2. Heart rate measurement
(1) In order to start the heart rate measurement, press "M (Measure On)" button.
* Measuring Notes
The initial 10 seconds are needed to initialize the measurement, it is
recommended during this first 10 seconds not to move your fingers and hands,
and make your hands as if holding an egg lightly.
(2) If the 10 seconds initialization is successful, the heart rate monitor displays your
current heart rate at the top of the LCD display.
*. Notice
In some cases (not usual), If it displays zero ‘0’ for a while, It is recommended to
press the ‘M'(Measure Off) button to stop measuring and restart monitor after reworn the device.
(3) During exercise, any of the buttons should not be pressed.
3. After using the heart rate monitor.
(1) In order to terminate the heart rate measurement, press ‘S (Stop)’ button.
The heart rate monitor will turn off all display. After you wear off the gloves, please
be kept charged by plugging in the adapter.
(2) Pressing ‘S(stop)’ button, If the monitor displays 'BUSY', you should not do any
operation and let it terminate automatically.
4. How to store and maintenance
(1) Storage environment : Temperature -10~55 ℃, humidity is kept at less than 95%.
(2) The following points should be taken when storing.
① not exposed to corrosive gases.
② should be kept away from moisture and dust.
③ should be kept clean.
5. Precautions during use
(1) Ware the sensing part with care to avoid application of excessive force.
(2) Remain stop during 10 to 20 seconds after pressing the ‘M(measure)’ button
(3) Do not stare at the light of the sensing part since the LED light is harmful if you
stare on.
(4) This device was developed for purposes described in this manual and the
manufacturer is not responsible for side effects caused by an improper purpose or
improper use.
(5) Before using the device and accessory, please check and confirm that there is no
faulty. When in doubt, do not use and notify the manufacturer or service center
immediately.
(6) This device should be repaired by an approved person and approved
organizations.
(7) This device should not be repaired by user itself.
(8) Use only standardized accessories which is provided with this device.
IV. Electrical rating
(1) The type and degree of protection to protect against electrical shock :
The internal power-type equipment, BF-type mounting
(2) Electrical Rating: DC 3.7V Lithium polymer battery
V. Matters
(1) The product name, model name (model): heart rate monitor (HRM-1000)
(2) the manufacturer's name and address:
- Company Name : H3 System Co., Ltd.
- Address: 3rd floor, Daedeok Bldg., 397-27, Doryong-dong, Yuseong-gu,
Daejeon city, Korea (republic of)
- Phone : +81-42-862-9313~4
- Homepage : http://www.h3system.co.kr
(3) manufacturer’s authorization and manufacturing product license number
- Manufacturer’s authorization: listed after approval
- Manufacturing product license number: listed after approval
(4) The manufacture’s serial number, manufacturing date, weight, packaging unit
- manufacture’s serial number: listed after manufacture
- Date of Manufacture: listed after manufacture
- Weight: 60g (excluding charging adapter)
- Packing: 1set
(5) How to use (including performance), and use precautions or warnings, Storage:
written at a separate attachment
(6) Purpose: To measure and display heart rate during exercise.
(7) Other necessary matters
① The type and degree of protection to protect against electrical shock :
The internal power-type equipment, BF-type mounting
② Electrical Rating: DC 3.7V Lithium polymer battery
(8) This device is for medical equipment (in Korea).
※ The above information is listed on the back of the device, packaging and
attachments.
Regulatory Statements to be included in the Users Guide for Sputnik
USA-Federal Communications Commission (FCC)
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy. If not installed and used in
accordance with the instructions, it may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to radio or television reception, which
can be determined by tuning the equipment off and on, the user is encouraged to try and
correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna
-Increase the distance between the equipment and the receiver.
-Connect the equipment to outlet on a circuit different from that to which the receiver is
connected.
-Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Create Date                     : 2012:01:09 15:58:47+09:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2012:03:17 05:58:49+04:30
Metadata Date                   : 2012:03:17 05:58:49+04:30
Format                          : application/pdf
Creator                         : Guest
Title                           : Microsoft Word - User's Manual _HRM-1000_.docx
Document ID                     : uuid:9fd4bdf1-552e-40a0-863a-072f77931d48
Instance ID                     : uuid:51237198-3665-4456-b099-443add3ef065
Page Count                      : 8
Author                          : Guest
EXIF Metadata provided by EXIF.tools
FCC ID Filing: X59-HRM-1000

Navigation menu