HARRIS TR-0057-E Base station transceiver (700 MHz band) User Manual User Guide
HARRIS CORPORATION Base station transceiver (700 MHz band) User Guide
HARRIS >
Contents
- 1. Overview Manual
- 2. User Guide
User Guide
User Guide Frequency Standard QFS-106 Model QFS-106 P/N 0150060XX Revision B August 2005 Brandywine Communications 2230 South Fairview Street Santa Ana, CA 92704 (714) 755 1050 (714) 755 0175 http://www.brandywinecomm.com MANUAL P/N 900000034 REV B FCC PART 15, CLASS A VERIFICATION INFORMATION TO THE USER FOR CLASS A DIGITAL DEVICE WARNING: This equipment has been tested and found to comply with the limits for Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction's manual, may cause interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense. The user is cautioned that changes and modifications made to the equipment without approval of the manufacturer could void the user's authority to operate this equipment. DOC. # FCC15AVER-B-7-01 REV. E 01/26/00 Revision History REVISION NC DATE 10-26-04 12-14-04 08-03-05 COMMENTS Original release of QFS-106 user guide. Revision of the rear panel and mechanical outline drawings. Revision of Section 3.1. MANUAL P/N 900000034 REV B Table of Contents Overview ................................................................................................................................. 5 1.1 Part Number Reference ................................................................................................. 5 Specifications .......................................................................................................................... 6 2.1 I/O and Environmental (Rear Panel) .............................................................................. 6 2.2 Switch and Indicator (Front Panel)................................................................................. 7 Unpacking and Installation...................................................................................................... 8 3.1 Unpacking ...................................................................................................................... 8 3.2 Installation ...................................................................................................................... 8 3.3 Connections ................................................................................................................... 8 Operation .............................................................................................................................. 10 4.1 Powering the QFS-106................................................................................................. 10 4.2 Loss of Input Signal...................................................................................................... 10 4.3 Loss of Output Signal ................................................................................................... 10 Calibration ............................................................................................................................. 11 Diagrams............................................................................................................................... 12 MANUAL P/N 900000034 REV B 1 Overview The Brandywine Communications QFS-106 is a high performance reference frequency standard distribution amplifier. The QFS-106 has two internal reference oscillator options. The QFS-106 may use either a free running Oven Controlled Crystal Oscillator (OCXO) or a free running Rubidium Oscillator. Also, the QFS-106 has various power supply options. The QFS-106 may use either AC or DC input power supplies. The QFS-106 provides six output channels of a single reference frequency, typically 10 MHz. The QFS-106 has six individually buffered low phase noise outputs. When more outputs are required, multiple QFS-106 units may be daisy-chained to a single reference. 1.1 Part Number Reference PART NUMBER 015006001 015006002 015006003 015006004 015006011 015006012 015006013 015006014 OSCILLATOR OCXO OCXO OCXO OCXO Rubidium Rubidium Rubidium Rubidium MANUAL P/N 900000034 REV B POWER SUPPLY 115/230 VAC 09 – 18 VDC 18 – 36 VDC 36 – 72 VDC 115/230 VAC 09 – 18 VDC 18 – 36 VDC 36 – 72 VDC 2 Specifications 2.1 I/O and Environmental (Rear Panel) SPECIFICATION Internal Reference Oscillator Reference Input Reference Output (Buffered from Reference Input) Outputs Phase Noise at 10 MHz Environmental Fuse Power Power Connection Dimension Weight DESCRIPTION -8 OCXO Stability 1 x 10 at -30° to -60°C -8 OCXO Aging 5 x 10 per year -10 Rubidium Stability ±1 x 10 at 0 to 50°C -11 Rubidium Aging 5 x 10 per month Label J8 Number of Reference Inputs 1 Input Frequency 10 MHz Standard Level 1 Vrms into 50 ohm Connector BNC Label J7 Number of Reference Outputs 1 Output Frequency 10 MHz Standard Level 1 Vrms into 50 ohm Distortion < 33 dBc Connector BNC Label Output 1 (J1), Output 2 (J2), Output 3 (J3), Output 4 (J4), Output 5 (J5), and Output 6 (J6) Number of Frequency Outputs 6 Buffered Outputs Frequency 10 MHz Standard Level 1 Vrms into 50 ohm Distortion < 33 dBc Connector BNC 1 Hz -90 dBc/Hz 10 Hz -110 dBc/Hz 100 Hz -140 dBc/Hz 1000 Hz -150 dBc/Hz 10000 Hz -157 dBc/Hz Temperature -30 to +60°C Humidity 95% non-condensing VDC Model 12 VDC and 4A VAC Model 115/230 VAC and 250mA VDC Power Supply 09 – 18 VDC 18 – 36 VDC 36 – 72 VDC VAC Power Supply 115/230 VAC VDC Connector DC Connector VDC Connector 2 Pin Pin A -> Positive Pin B -> Negative VAC Connector AC Connector Length (Rack Mount & Chassis) 19.00” and 17.00” Height 1.720” Width 6.150” Weight Typically 3 lbs MANUAL P/N 900000034 REV B 2.2 Switch and Indicator (Front Panel) SWITCH/INDICATOR POWER SWITCH POWER LED OUTPUT MONITOR 1 LED OUTPUT MONITOR 2 LED OUTPUT MONITOR 3 LED OUTPUT MONITOR 4 LED OUTPUT MONITOR 5 LED OUTPUT MONITOR 6 LED PLL LED COLOR –– GREEN GREEN GREEN GREEN GREEN GREEN GREEN RED DESCRIPTION Used to switch the unit on and off Indicates that the unit has primary power Indicates that Output 1 is present Indicates that Output 2 is present Indicates that Output 3 is present Indicates that Output 4 is present Indicates that Output 5 is present Indicates that Output 6 is present Indicates that the unit is in power up mode or not locked to the reference input Indicates that the unit is phased locked to the reference input Indicates that the rubidium oscillator has reached resonance lock if installed Used to calibrate the oscillator GREEN RB LOCKED LED CALIBRATE (POTENTIOMETER) GREEN –– MANUAL P/N 900000034 REV B 3 Unpacking and Installation 3.1 Unpacking Carefully remove the QFS-106 from the shipping carton. The following items should be included in the shipment: • 1 QFS-106 • 1 user guide • 1 power cord • 1 power mating connector (DC voltage only) Note the power connection on the rear of the QFS-106 chassis. Please take note of the voltage displayed near this power connection. If the AC or DC voltage setting is incorrect, use a small screw driver to remove the fuse holder. Reverse the fuse holder and re-insert the fuse holder, making sure that the correct AC or DC voltage is now displayed on the rear panel of the QFS-106. Use the supplied power mating connector for the QFS-106 unit (DC voltage only). The user must connect the wires to the connector as shown in the table below. DC MODEL Pin A Pin B Mating Connector Strain Relief 3.2 DESCRIPTION Positive input voltage Negative input voltage Amphenol 97-3106A-10SL-4S Amphenol 97-3057-1004-1 Installation The QFS-106 may be bolted directly onto a 19” rack mount enclosure. 3.3 Connections Connect the power source to the QFS-106. Now connect the input reference signal and output reference signals to the appropriate connectors on the rear panel of the QFS-106. The Reference Output connector may be used when daisy-chaining multiple QFS-106 units. MANUAL P/N 900000034 REV B QFS-106 Power QFS-106 REF IN REF OUT 1 2 3 4 5 6 User’s Equipment User’s Equipment QFS-106 REF IN REF OUT 1 2 3 4 5 6 User’s Equipment QFS-106 REF IN REF OUT 1 2 3 4 5 6 User’s Equipment Additional QFS-106 Units Figure 1 Daisy-Chain Interconnection When daisy-chaining multiple QFS-106 units, these units should be connected as shown in Figure 1. This configuration ensures that all outputs are accurately locked to a common reference with minimal injection of the phase lock loop noise. MANUAL P/N 900000034 REV B 4 Operation 4.1 Powering the QFS-106 Once all the connections to the QFS-106 have been made, apply power to the unit by switching the power switch to the on position. The power switch is located on the rear panel of the unit. The Power LED and Output Monitor LEDs (1 – 6) on the front panel of the unit will illuminate green. Please note that units fitted with the quartz oscillators will take approximately five minutes to warm up and these units will reach full accuracy after twenty-four hours. Units fitted with the rubidium oscillators will take approximately ten minutes to warm up. 4.2 Loss of Input Signal The PLL LED illuminates green when an input signal is present on the Reference Input connector on the rear panel of the unit. If the reference input fails, the front panel PLL LED will extinguish. 4.3 Loss of Output Signal The Output Monitor LEDs (1 – 6) illuminate green when output signals are present on the Outputs connectors on the rear panel of the unit. If one or more outputs fail, the front panel Output Monitor LEDs (1 – 6) will extinguish. Please note that a short circuit on the output cable may not always trigger the output alarm. 10 MANUAL P/N 900000034 REV B 5 Calibration The QFS-106 is a free running standard that requires periodic recalibration. The unit must be calibrated against a frequency standard that is at least ten times more accurate than the oscillator fitted in the QFS-106 unit. Therefore OCXO oscillator units must be calibrated against a rubidium reference. Rubidium oscillator units must be calibrated against a cesium frequency standard or GPS disciplined rubidium. The front panel mounted potentiometer is used to adjust the frequency of the QFS-106 unit. The table below describes this calibration. OUTPUT Calibrate Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 POTENTIOMETER 20 turn potentiometer (front panel) 10 turn potentiometer (rear panel) 10 turn potentiometer (rear panel) 10 turn potentiometer (rear panel) 10 turn potentiometer (rear panel) 10 turn potentiometer (rear panel) 10 turn potentiometer (rear panel) OUTPUT LEVEL ADJUSTMENT Frequency standard calibration 7 – 13 dBm 7 – 13 dBm 7 – 13 dBm 7 – 13 dBm 7 – 13 dBm 7 – 13 dBm 11 MANUAL P/N 900000034 REV B 6 Diagrams FIGURE DESCRIPTION QFS-106 Front Panel (AC and DC Models) QFS-106 Rear Panel (AC Model) QFS-106 Rear Panel (DC Model) QFS-106 Mechanical Outline (AC Model) QFS-106 Mechanical Outline (DC Model) 12 MANUAL P/N 900000034 REV B
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2005:08:03 13:37:55Z Modify Date : 2009:07:29 08:35:54-04:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2009:07:29 08:35:54-04:00 Producer : Acrobat Distiller 4.05 for Windows Format : application/pdf Document ID : uuid:24198d7f-74c8-4d2f-803a-118604fdc7be Instance ID : uuid:dd290b33-2929-4065-aa90-d5a01eb76399 Page Count : 17EXIF Metadata provided by EXIF.tools