HID Global 609XA 61xxA bioCLASS Reader User Manual 6096 901 A2

HID Global Corporation 61xxA bioCLASS Reader 6096 901 A2

Contents

Users Manual

Installation Guide       iCLASS Reader Models bio500, RWKL550 & RWKLB575                An ASSA ABLOY Group company                     ASSA ABLOY _____________________________________________________________________________________________________ HID Corporation  9292 Jeronimo Road   Irvine, CA 92618-1905 USA TEL (949) 598-1600  (800) 237-7769  FAX (949) 598-1690 Web page - www.hidcorp.com e-mail – tech@hidcorp.com  iCLASS Biometric/LCD keypad Reader Install Manual 6096-901 Rev A.2  Page 1 of 4 PARTS INCLUDED SPECIFICATIONS • 1 - iCLASS LCD Keypad Reader with optional Bio  •  Reader Input Voltage:        9-12 VDC  •  1 - Installation Manual  •  Current Range:                  350 mA standby / 520 mA peak. •  2 - #6-32 x .25” x  Phillips machine screws  • Cable distance to Host:     50 ft (15 m) max – RS-232. •  3 - #6-32 x .375” Phillips self-tapping machine screws     4000 ft (1216 m) max – RS-485 •  2 - #6 x 1.5” Phillips sheet metal screws   16 Gauge Wire  500 ft (152 m) max – Wiegand •  2 - #6-32 x .375” Spanner security screws   20 Gauge Wire  200 ft (60 m) max – Wiegand •  1 - 10 Position Phoenix Plug    •  1 - 8 Position Phoenix Plug  •  Op. Temperature:            32 °F - +113 °F (0 °C – +45 °C) •  1- Foam Gasket  •  Open collector output:  Sink – 40 mA, source – 1 mA.    Recommended:    •  Up to 10 wire splices •  Security Tool (for security screw) HID 04-0001-03  Standards:  •  Cable, 9 conductor, 22 AWG, shielded (Wiegand) •  Linear 12 VDC, 1 A Power Supply •  Read/Write capability in ISO 15693 mode with HID iCLASS credentials. •  Cable , 6 conductor, 22 AWG, shielded (Serial) •  Metal or plastic junction box •  Read/Write capability in ISO 14443B mode with HID iCLASS 16KS. •  Magnetic Tamper switch - Ademco 945T, Sentrol 1038T, GRI 100T or 110T or Aleph DC-2531 •  Read capability of CSN/UID in ISO 14443A mode with HID Mifare and other 3rd party Mifare credentials.  Description                                                       RWKLB575                                          RWKL550                                                bio500   The bioCLASS range is intended for indoor use only and should never be mounted on an exterior wall.  INSTALLATION   1- Install Tamper Switch An internal magnet provides tamper indication when used with a magnetic reed switch connected to an external alarm system.  Locate Switch behind the left side of the mounting plate, centered between the mounting holes.                                               Electrical Back Box  Wall Surface
Installation Guide       iCLASS Reader Models bio500, RWKL550 & RWKLB575                An ASSA ABLOY Group company                     ASSA ABLOY _____________________________________________________________________________________________________ HID Corporation  9292 Jeronimo Road   Irvine, CA 92618-1905 USA TEL (949) 598-1600  (800) 237-7769  FAX (949) 598-1690 Web page - www.hidcorp.com e-mail – tech@hidcorp.com  iCLASS Biometric/LCD keypad Reader Install Manual 6096-901 Rev A.2  Page 2 of 4 2 - Install Mounting Plate  Attach the mounting plate to the wall or electrical back box,  using the long or short backplate as appropriate.    Long – biometric    Short - keypad              3 – Biometric Reader Mounting   1.  Connect the ribbon cable from the bio500 to connector J8 on the RWKL550.  Ensure that pin1 of the ribbon cable is aligned with pin1 of the connector. 2.  Slide the reader onto the long backplate, ensuring that the tongue of the backplate is located in the slot at the top of the reader and retain with a screw. 3.  Align the biomodule with the RWKL550 body and insert a second screw.                   RWKL550 bio500 Ribbon cable
Installation Guide       iCLASS Reader Models bio500, RWKL550 & RWKLB575                An ASSA ABLOY Group company                     ASSA ABLOY _____________________________________________________________________________________________________ HID Corporation  9292 Jeronimo Road   Irvine, CA 92618-1905 USA TEL (949) 598-1600  (800) 237-7769  FAX (949) 598-1690 Web page - www.hidcorp.com e-mail – tech@hidcorp.com  iCLASS Biometric/LCD keypad Reader Install Manual 6096-901 Rev A.2  Page 3 of 4 4 – Keypad Reader Mounting   1.  Slide the reader onto the short back plate, ensuring              that the tongue of the backplate is located in the slot               at the top of the reader and retain with a screw.        5- Connecting  Serial Port  Wiegand Port  8 Pin Terminal  Function  10 Pin Terminal Color-coded Pigtail Function 1 Ground  10 Violet  Actuator Signal 2  Y / RS-232 TX  9  Blue  Hold1 3 Z  8 Yellow  Speaker1 4 Ground  7 Drain  Shield Ground2 5  RS485B / RS-232 RX  6  Brown  Red LED1 6 RS-485A  5 Orange  Green LED1 7 Ground  4 White  Data 1 8 DC+  3 Green  Data 0 2 Black  Ground  1  Red  +DC (9-12 VDC)3  1 Optional Connections  2 Drain wire can be used for data return line when a separate power supply is used. 3 +DC, Return & Drain wires are common between the Wiegand and Serial Ports.       6- Testing A.  Turn Power On – Watch the sign-on LED and hear the speaker tone sequences. B.  Read Card – Present a valid card to the reader and verify the visual and audio feedbacks.  7- Upgrading an RWKL550 Reverse installation step 4 in order to remove the reader from the backplate. Replace short backplate with a long backplate and follow the Biometric Reader Mounting instruction, steps 1-3.   Optional Features FCC WARNING:  This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  For proper regulatory compliance, the drain wire should be disconnected at the power supply end of the cable. The reader is intended to be powered from a limited power source output of a previously certified power supply. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.  RS232/485 interface/Host Mode - for applications requiring a serial link.  See Protocol Document 6090-902 for information Configuration Options - Configure LED, Speaker, and other features.  See How To Order Guide or iCLASS Application Note for details Hold Input – when asserted, this line either buffers a card read or disables a card read until released, as configured.
Installation Guide          iCLASS Reader Models bio500, RWKL550 & RWKLB575   HID Corporation  9292 Jeronimo Road   Irvine, CA 92618-1905 USA TEL (949) 598-1600  (800) 237-7769  FAX (949) 598-1690 Web page - www.hidcorp.com e-mail – tech@hidcorp.com  iCLASS Biometric/LCD keypad Reader Install Manual 6096-901 Rev A.2  Page 4 of 4

Navigation menu