HID Global 609XA 61xxA bioCLASS Reader User Manual 6096 901 A2
HID Global Corporation 61xxA bioCLASS Reader 6096 901 A2
Contents
- 1. Manual
- 2. Users Manual
Users Manual
Installation Guide iCLASS Reader Models bio500, RWKL550 & RWKLB575 PARTS INCLUDED SPECIFICATIONS • • • • • • • • • • • 1 - iCLASS LCD Keypad Reader with optional Bio 1 - Installation Manual 2 - #6-32 x .25” x Phillips machine screws 3 - #6-32 x .375” Phillips self-tapping machine screws 2 - #6 x 1.5” Phillips sheet metal screws 2 - #6-32 x .375” Spanner security screws 1 - 10 Position Phoenix Plug 1 - 8 Position Phoenix Plug 1- Foam Gasket • Reader Input Voltage: Current Range: Cable distance to Host: 16 Gauge Wire 20 Gauge Wire • • Op. Temperature: Open collector output: 9-12 VDC 350 mA standby / 520 mA peak. 50 ft (15 m) max – RS-232. 4000 ft (1216 m) max – RS-485 500 ft (152 m) max – Wiegand 200 ft (60 m) max – Wiegand 32 °F - +113 °F (0 °C – +45 °C) Sink – 40 mA, source – 1 mA. Recommended: • • • • • • • Up to 10 wire splices Security Tool (for security screw) HID 04-0001-03 Cable, 9 conductor, 22 AWG, shielded (Wiegand) Linear 12 VDC, 1 A Power Supply Cable , 6 conductor, 22 AWG, shielded (Serial) Metal or plastic junction box Magnetic Tamper switch - Ademco 945T, Sentrol 1038T, GRI 100T or 110T or Aleph DC-2531 Standards: • • • Read/Write capability in ISO 15693 mode with HID iCLASS credentials. Read/Write capability in ISO 14443B mode with HID iCLASS 16KS. Read capability of CSN/UID in ISO 14443A mode with HID Mifare and other 3rd party Mifare credentials. Description RWKLB575 RWKL550 bio500 The bioCLASS range is intended for indoor use only and should never be mounted on an exterior wall. INSTALLATION 1- Install Tamper Switch An internal magnet provides tamper indication when used with a magnetic reed switch connected to an external alarm system. Locate Switch behind the left side of the mounting plate, centered between the mounting holes. Electrical Back Box Wall Surface An ASSA ABLOY Group company ASSA ABLOY _____________________________________________________________________________________________________ HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690 Web page - www.hidcorp.com e-mail – tech@hidcorp.com iCLASS Biometric/LCD keypad Reader Install Manual 6096-901 Rev A.2 Page 1 of 4 Installation Guide iCLASS Reader Models bio500, RWKL550 & RWKLB575 2 - Install Mounting Plate Attach the mounting plate to the wall or electrical back box, using the long or short backplate as appropriate. Long – biometric Short - keypad 3 – Biometric Reader Mounting 1. Connect the ribbon cable from the bio500 to connector J8 on the RWKL550. Ensure that pin1 of the ribbon cable is aligned with pin1 of the connector. 2. Slide the reader onto the long backplate, ensuring that the tongue of the backplate is located in the slot at the top of the reader and retain with a screw. 3. Align the biomodule with the RWKL550 body and insert a second screw. RWKL550 Ribbon cable bio500 An ASSA ABLOY Group company ASSA ABLOY _____________________________________________________________________________________________________ HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690 Web page - www.hidcorp.com e-mail – tech@hidcorp.com iCLASS Biometric/LCD keypad Reader Install Manual 6096-901 Rev A.2 Page 2 of 4 Installation Guide iCLASS Reader Models bio500, RWKL550 & RWKLB575 4 – Keypad Reader Mounting 1. Slide the reader onto the short back plate, ensuring that the tongue of the backplate is located in the slot at the top of the reader and retain with a screw. 5- Connecting Serial Port 8 Pin Terminal Function Ground Y / RS-232 TX Ground RS485B / RS-232 RX RS-485A Ground DC+ Wiegand Port 10 Pin Terminal 10 Color-coded Pigtail Violet Blue Yellow Drain Brown Orange White Green Black Red Function Actuator Signal Hold Speaker Shield Ground Red LED Green LED Data 1 Data 0 Ground +DC (9-12 VDC) Optional Connections Drain wire can be used for data return line when a separate power supply is used. +DC, Return & Drain wires are common between the Wiegand and Serial Ports. 6- Testing A. B. Turn Power On – Watch the sign-on LED and hear the speaker tone sequences. Read Card – Present a valid card to the reader and verify the visual and audio feedbacks. 7- Upgrading an RWKL550 Reverse installation step 4 in order to remove the reader from the backplate. Replace short backplate with a long backplate and follow the Biometric Reader Mounting instruction, steps 1-3. Optional Features RS232/485 interface/Host Mode - for applications requiring a serial link. See Protocol Document 6090-902 for information Configuration Options - Configure LED, Speaker, and other features. See How To Order Guide or iCLASS Application Note for details Hold Input – when asserted, this line either buffers a card read or disables a card read until released, as configured. FCC WARNING: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For proper regulatory compliance, the drain wire should be disconnected at the power supply end of the cable. The reader is intended to be powered from a limited power source output of a previously certified power supply. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. An ASSA ABLOY Group company ASSA ABLOY _____________________________________________________________________________________________________ HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690 Web page - www.hidcorp.com e-mail – tech@hidcorp.com iCLASS Biometric/LCD keypad Reader Install Manual 6096-901 Rev A.2 Page 3 of 4 Installation Guide iCLASS Reader Models bio500, RWKL550 & RWKLB575 HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690 Web page - www.hidcorp.com e-mail – tech@hidcorp.com iCLASS Biometric/LCD keypad Reader Install Manual 6096-901 Rev A.2 Page 4 of 4
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 4 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:d75a5c19-7470-4f91-bef4-d7f0103750a6 Producer : Acrobat Distiller 6.0 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2004:09:09 09:45:49-06:00 Create Date : 2004:09:09 09:45:49-06:00 Document ID : uuid:8225c79d-64b0-4404-8f6d-6e4628bfbd70 Format : application/pdf Title : Microsoft Word - 6096-901_A2.doc Creator : rbousfield Author : rbousfieldEXIF Metadata provided by EXIF.tools