HID Global 609XA 61xxA bioCLASS Reader User Manual 6096 901 A2

HID Global Corporation 61xxA bioCLASS Reader 6096 901 A2

Contents

Users Manual

Download: HID Global 609XA 61xxA bioCLASS Reader User Manual 6096 901 A2
Mirror Download [FCC.gov]HID Global 609XA 61xxA bioCLASS Reader User Manual 6096 901 A2
Document ID495211
Application ID1KhivOmWwPlJkzVxQs+Fyg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize82.7kB (1033770 bits)
Date Submitted2004-12-09 00:00:00
Date Available2004-12-03 00:00:00
Creation Date2004-09-09 09:45:49
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2004-09-09 09:45:49
Document TitleMicrosoft Word - 6096-901_A2.doc
Document CreatorPScript5.dll Version 5.2
Document Author: rbousfield

Installation Guide
iCLASS Reader Models bio500, RWKL550 & RWKLB575
PARTS INCLUDED
SPECIFICATIONS
•
•
•
•
•
•
•
•
•
•
•
1 - iCLASS LCD Keypad Reader with optional Bio
1 - Installation Manual
2 - #6-32 x .25” x Phillips machine screws
3 - #6-32 x .375” Phillips self-tapping machine screws
2 - #6 x 1.5” Phillips sheet metal screws
2 - #6-32 x .375” Spanner security screws
1 - 10 Position Phoenix Plug
1 - 8 Position Phoenix Plug
1- Foam Gasket
•
Reader Input Voltage:
Current Range:
Cable distance to Host:
16 Gauge Wire
20 Gauge Wire
•
•
Op. Temperature:
Open collector output:
9-12 VDC
350 mA standby / 520 mA peak.
50 ft (15 m) max – RS-232.
4000 ft (1216 m) max – RS-485
500 ft (152 m) max – Wiegand
200 ft (60 m) max – Wiegand
32 °F - +113 °F (0 °C – +45 °C)
Sink – 40 mA, source – 1 mA.
Recommended:
•
•
•
•
•
•
•
Up to 10 wire splices
Security Tool (for security screw) HID 04-0001-03
Cable, 9 conductor, 22 AWG, shielded (Wiegand)
Linear 12 VDC, 1 A Power Supply
Cable , 6 conductor, 22 AWG, shielded (Serial)
Metal or plastic junction box
Magnetic Tamper switch - Ademco 945T, Sentrol
1038T, GRI 100T or 110T or Aleph DC-2531
Standards:
•
•
•
Read/Write capability in ISO 15693 mode with HID iCLASS
credentials.
Read/Write capability in ISO 14443B mode with HID iCLASS
16KS.
Read capability of CSN/UID in ISO 14443A mode with HID
Mifare and other 3rd party Mifare credentials.
Description
RWKLB575
RWKL550
bio500
The bioCLASS range is intended for indoor use only and should never be mounted on an exterior wall.
INSTALLATION
1- Install Tamper Switch
An internal magnet provides tamper indication when used with a magnetic reed switch connected to an external alarm system.
Locate Switch behind the left side of the mounting plate, centered between the mounting holes.
Electrical Back Box
Wall Surface
An ASSA ABLOY Group company
ASSA ABLOY
_____________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page - www.hidcorp.com e-mail – tech@hidcorp.com
iCLASS Biometric/LCD keypad Reader Install Manual 6096-901 Rev A.2 Page 1 of 4
Installation Guide
iCLASS Reader Models bio500, RWKL550 & RWKLB575
2 - Install Mounting Plate
Attach the mounting plate to the wall or electrical back box,
using the long or short backplate as appropriate.
Long – biometric
Short - keypad
3 – Biometric Reader Mounting
1. Connect the ribbon cable from the bio500 to connector J8 on the RWKL550. Ensure that pin1 of the ribbon
cable is aligned with pin1 of the connector.
2. Slide the reader onto the long backplate, ensuring that the tongue of the backplate is located in the slot at
the top of the reader and retain with a screw.
3. Align the biomodule with the RWKL550 body and insert a second screw.
RWKL550
Ribbon cable
bio500
An ASSA ABLOY Group company
ASSA ABLOY
_____________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page - www.hidcorp.com e-mail – tech@hidcorp.com
iCLASS Biometric/LCD keypad Reader Install Manual 6096-901 Rev A.2 Page 2 of 4
Installation Guide
iCLASS Reader Models bio500, RWKL550 & RWKLB575
4 – Keypad Reader Mounting
1. Slide the reader onto the short back plate, ensuring
that the tongue of the backplate is located in the slot
at the top of the reader and retain with a screw.
5- Connecting
Serial Port
8 Pin Terminal
Function
Ground
Y / RS-232 TX
Ground
RS485B / RS-232 RX
RS-485A
Ground
DC+
Wiegand Port
10 Pin Terminal
10
Color-coded Pigtail
Violet
Blue
Yellow
Drain
Brown
Orange
White
Green
Black
Red
Function
Actuator Signal
Hold
Speaker
Shield Ground
Red LED
Green LED
Data 1
Data 0
Ground
+DC (9-12 VDC)
Optional Connections
Drain wire can be used for data return line when a separate power supply is used.
+DC, Return & Drain wires are common between the Wiegand and Serial Ports.
6- Testing
A.
B.
Turn Power On – Watch the sign-on LED and hear the speaker tone sequences.
Read Card – Present a valid card to the reader and verify the visual and audio feedbacks.
7- Upgrading an RWKL550
Reverse installation step 4 in order to remove the reader from the backplate.
Replace short backplate with a long backplate and follow the Biometric Reader Mounting instruction, steps 1-3.
Optional Features
RS232/485 interface/Host Mode - for applications requiring a serial link. See Protocol Document 6090-902 for information
Configuration Options - Configure LED, Speaker, and other features. See How To Order Guide or iCLASS Application Note for details
Hold Input – when asserted, this line either buffers a card read or disables a card read until released, as configured.
FCC WARNING:
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired operation. For proper regulatory compliance, the drain wire
should be disconnected at the power supply end of the cable. The reader is intended to be powered from a limited power source output of a previously certified
power supply. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
An ASSA ABLOY Group company
ASSA ABLOY
_____________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page - www.hidcorp.com e-mail – tech@hidcorp.com
iCLASS Biometric/LCD keypad Reader Install Manual 6096-901 Rev A.2 Page 3 of 4
Installation Guide
iCLASS Reader Models bio500, RWKL550 & RWKLB575
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690 Web page - www.hidcorp.com e-mail –
tech@hidcorp.com
iCLASS Biometric/LCD keypad Reader Install Manual 6096-901 Rev A.2 Page 4 of 4

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 4
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:d75a5c19-7470-4f91-bef4-d7f0103750a6
Producer                        : Acrobat Distiller 6.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2004:09:09 09:45:49-06:00
Create Date                     : 2004:09:09 09:45:49-06:00
Document ID                     : uuid:8225c79d-64b0-4404-8f6d-6e4628bfbd70
Format                          : application/pdf
Title                           : Microsoft Word - 6096-901_A2.doc
Creator                         : rbousfield
Author                          : rbousfield
EXIF Metadata provided by EXIF.tools
FCC ID Filing: JQ6609XA

Navigation menu