HID Global ER40C ER40C , RFID Reader User Manual EdgeReader EdgePlus Installation Guide

HID Global Corporation ER40C , RFID Reader EdgeReader EdgePlus Installation Guide

User Manual

Edge is the next evolution in access control hardware solutions. A true IP solution that meets the demands of open architecture, IP-centric environments, Edge provides fully distributed intelligence and decision making right to the door, leveraging the IT infrastructure to the maximum extent possible. Wire the Edge device to Hi-O interface modules to provide connectivity to electronic door components and access control readers.Hi-O involves devices with built-in intelligence and a CANbus that links all the devices together. Hi-O CANbus data trafc can be password protected and encrypted, or both. Each Hi-O device (such as the push plate, electric strike, card reader, door operator) is connected to the CANbus by a single, four-wire cable. Two of the wires supply power and the other two are used for data communication.SpecicationsCONNECTION PARAMETER CONDITIONS VALUE OPERATING TEMPERTURE CABLE LENGTHPoE Power (input)Voltage - Nominal - 48 VDC32° - 122°F(0° - 50° C)Hi-O CAN Bus  = 30 ft (9 m)  -  22 AWG ● 0.65mm ● 0.33mm2  = 75 ft (23 m)  -  18 AWG ● 1.02mm ● 0.82mm2RJ45  = 328 ft (100 m)  -  Category 5 KCurrent - Normal Standby Condition (NSC) CAN PWR - not loaded 75 mACurrent - Maximum CAN PWR - max load 275 mA +DC (input)Voltage - 12 VDC - 24 VDCCurrent - Normal Standby Condition (NSC)12 VDCCAN PWR disconnected 190 mACurrent - Normal Standby Condition (NSC)24 VDCCAN PWR disconnected 110 mACurrent - Maximum 12 VDC 2.2 ACurrent - Maximum 24 VDC 2.1 ACAN PWR (output)Voltage - Nominal PoE 24 VDCCurrent - Maximum PoE 300 mAVoltage - Nominal + DC + DCCurrent - Maximum + DC 2 Amp - AUX limitedEdgeEdgeReader® and EdgePlus®Models: EH400, EHR40, EHRP40, EH400-K ER40C, ERP40C InstallatIon GuIde82000-920, Rev A.1December 10, 2009© 2009 HID Global Corporation.  All rights reserved.15370 Barranca ParkwayIrvine, CA 92618-2215USADRAFT
EdgeReader and EdgePlus EH400, EHR40, EHRP40, EH400-K82000-920 A.1 INSTALLATION GUIDE2©2009 HID Global Corporation. All rights reserved.Mounting  WiringEdgeReader and EdgePlusGNDDC InEthernet / PoEAuto-DetectedCAN TerminationResistor(Default - IN)3.3 VDC LEDCAN-LO  (Brown)CAN-HI (White)GND (Black)CAN PWR (Red)ES400, ER40 or ERP40 (Rear View)Hi-O DeviceEthernetActivity LEDATTENTIONObserve precautions for handlingELECTROSTATIC SENSITIVE DEVICESJunction box not included.DRAFT
82000-920 A.1INSTALLATION GUIDE 3©2009 HID Global Corporation. All rights reserved.EdgeReader and EdgePlusEH400, EHR40, EHRP40, EH400-KEdgePlus - EH400-KHi-O Group Select Jumper Short = Group 1, Open = Group 2Outside Door   Inside Door(                       )1  P3  12 1  P1  4CAN V+ (12 VDC or 24 VDC)CAN GroundCAN HighCAN Low+12V OUT+12V GNDDATA0/DATADATA1/CLKTAMPER OUTGRN LEDRED LEDHOLDNO TAMPERBEEPERREADER TAMPERTAMPER GNDGRP SELREXREX Return10  P3  1 4  P1  1BATTBATT ReturnHi-O Group Select Jumper Short = Group 1, Open = Group 2Outside Door   Inside Door(                       )ACAC ReturnNo TamperTamper OutAUX N.O.AUX N.C.AUX CommonStrike N.O.Strike N.C.Strike CommonRelay Jumpers6  P10  1P9P5P8P6P4P7AUXPWR +VAUXPWR VDoorDoor ReturnInstall Edge to BackplateDRAFT
EdgeReader and EdgePlus EH400, EHR40, EHRP40, EH400-K82000-920 A.1 INSTALLATION GUIDE4©2009 HID Global Corporation. All rights reserved.ContactContact Edge through one of the following methods:Direct ConnectIf Edge will be connected to a network using static IP addressing or if the Discovery GUI is not installed on the PC, use this method.Note: The computer must be running Windows 2000 or XP and be congured for DHCP.1.  Disconnect the computer from the network and directly connect Edge to the computer with an Ethernet cable.2.  Click Start > Run. Enter ipcong /renew ↵3.  Access a web browser and enter 169.254.242.121 into the Address eld ↵OPIN Discovery/Update ApplicationUse the OPIN Discovery / Update Application on a computer to locate, connect and update Edge.  System Requirements:  Java 6.0 or later. Go to www.java.com to download.Operating Systems:  Windows XP and Fedora 8.Find the OPIN Discovery / Update Application at www.ShareMethods.com > OPIN > Firmware > 2.3.x. Save the les to your local harddrive.The Edge must be connected to the network, and power applied, before the device is discovered.1.  With a computer connected to the same network as Edge, double-click opin-update.jar. The OPIN Discovery / Update Application opens and the Controller Table populates.Note: If the Controller Table does not populate, go to Edit > Broadcast Address. The default broadcast address is 255.255.255.255. Some network switches may block this transmission. If this is the case, change the subnet to match the network, for example 10.7.255.255. Click Save.2.  Select the desired device from the list.3.  From Path to Update Package frame, browse to the rmware location on the computer.4.  Click Install. Firmware is installed.EH400 - Provides additional functionality to not only Install rmware, but to Changeover, and Rollback rmware updates. Once rmware is installed, click Changeover to switch to the updated rmware. Click Rollback to switch back to the previoius rmware version.5.  View the Status Log for each status while performing Discovery and Update functions.CongureThe web browser will prompt for login information.  From the Login screen enter admin, leaving the Password eld empty.  Follow the instructions on the web browser screen to congure Edge.Hi-O Interface ModulesHi-O interface modules are used to interface the Edge device (EdgeReader or EdgePlus) with door electronic components. Components include access control readers, strike, magnetic lock, request to exit, door position switch, and auxillary devices.For Hi-O interface module wiring, see their prospective Installation Guides.Go to www.hidglobal.com > Knowledge Center > Resources > Document Library. Search the document type as a Installation Guide.Model Description Part NumberEDM-M EdgeModule Door 82342EIM-M EdgeModule Input 82340EWM-M EdgeModule Wiegand 82360EDWM-M EdgeModule Door & Wiegand 82363AMELM EdgeModule Lock 82301EVM EdgeModule Voltage 82365DRAFT
RegulatoryULConnect only to a Listed Access Control / Burglary power-limited power supply, or Listed Access Control / Burglary PoE (Power-over-Ethernet) adapter. All National and local Electrical codes apply.  Install in accordance with NFPA70 (NEC), Local Codes, and authorities having jurisdiction. Furthermore, install within a Listed electrical box. All interconnected devices must be Listed. Host-based security, Ethernet / Host Communication, has not been evaluated by UL. Ethernet port has been evaluated for supplemental use only.The following have been evaluated as standalone products: EdgePlus model E400Cxxx and edgeReader model ERP40Cxxx.EdgePlus was evaluated for use with all Listed HID Global Wiegand models: iCLASS, Indala Prox, HID Prox, bioCLASS, SmartID, SmartTRANS, and Mag Stripe series (with and without keypad), up to 128-bit formats. EdgePlus was evaluated for use with all HID Global Hi-O iCLASS readers.EdgePlus and EdgeReader are UL Listed for installation in the unprotected area, as well as within the protected area.FCC / CANADA RADIO CERTIFICATIONFor ER40/ESR40 and ERW400 models:  Reader portion (iCLASS R40 and RW400 models) certied separately.These devices comply with part 15 of the FCC rules.Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.Le fonctionnement est soumis aux deux conditions suivantes : (1) Ce dispositif ne peut pas causer de perturbations nuisibles et (2) ce dispositif doit accepter toute perturbation quelconque qu’il reçoit, y compris desFor all models (controller portion): FCC Class A  Canada Class A  CE Mark – Europe (EU)  C-Tick – Australia and New Zealand  VCCI – JapanClass A Digital Devices - FCC Compliance Statement: This equipment has been tested and found to comply with the limits for a Class. A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.  For regulatory compliance, all connection wires must be bundled together.CE MARKINGHID Global hereby declares that these proximity readers are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.The controller portion is in compliance with the essential requirements and other relevant provision of Directive 2004/108/EC.JAPAN MICこの装置は認証済みです。TAIWAN DGT/NCC經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。低功率射頻電機之使用不得影響飛航安全及干擾合法通信;According to «Administrative Regulations on Low Power Radio Waves Radiated Devices» Without permission granted by the DGT, any company, enterprise, or user is not allowed to change frequency, enhance transmitting power or alter original characteristic as well as performance to a approved low power radio-frequency devices. The low power radio-frequency devices shall not inuence aircraft security and interfere legal communications; If found, the user shall cease operating immediately until no interference is achieved. The said legal communications means radio communications is operated in compliance with the Telecommunications Act. The low power radio-frequency devices must be susceptible with the interference from legal communications or ISM radio wave radiated devices.hidglobal.comACCESS experience.North America15370 Barranca ParkwayIrvine, CA 92618USAPhone:   800 237 7769Support:   866 607 7339Fax:   949 732 2120Email:   tech@hidglobal.comAsia Pacific19/F 625 King’s RoadNorthPoint, Island EastHong KongPhone:   852 3160 9800Support:   852 3160 9833Fax:   852 3160 4809Email:   asiasupport@hidglobal.comEurope, Middle East & AfricaPhoenix RoadHaverhill, Suolk CB9 7AEEnglandPhone:   +44 1440 714 850Support:  +44 1440 711 822Fax:   +44 1440 714 840Email:   eusupport@hidglobal.comHID Global84000-920 Rev A.1Patent Pending© 2009 HID Global Corporation.  All rights reserved.Check reader label for current regulatory approvals.HID, HID Global, Edge, EdgeReader and EdgePlus are the trademarks or registered trademarks of HID Global Corporation in the U.S. and other countries.DRAFT

Navigation menu