HID Global RMPK40C RFID Reader/Keypad with Magstripe User Manual Edge Relay Module Installation Guide

HID Global Corporation RFID Reader/Keypad with Magstripe Edge Relay Module Installation Guide

User Manual

OverviewThis multiCLASS reader is a combination iCLASS Keypad, HID Prox and Magstripe reader which provides secure PIV compatibility. Flexibility is at your ngertips, use this reader simultaneously for magnetic stripe, HID Prox and high frequency smart cards. For Wiring instructions and Specications, see the iCLASS Keypad Installation Guide (P/N 6404-901).SpecicationsPRODUCTPRODUCTOPRODUITPRODUTOPRODUKTPRODOTTO製品产品제품ИЗДЕЛИЕBASE PART NUMBERNÚMERO DE COMPONENTE BASERÉFÉRENCE DE BASENÚMERO DAS PEÇAS BÁSICASHAUPTTEILENUMMERNUMERO PARTE DI BASE基本部品番号基本部件编号기본부품 번호БАЗОВЫЙ НОМЕР ИЗДЕЛИЯINPUT VOLTAGE (VDC)TENSIÓN DE ENTRADA (VCC)TENSION D’ALIMENTATION (Vcc)VOLTAGEM DE ENTRADA (VCC)EINGANGSSPANNUNG (VDC)TENSIONE IN INGRESSO (V c.c.)入力電圧(VDC)输入电压 (VDC)입력 전압(VDC)НАПРЯЖЕНИЕ ПИТАНИЯ  (В постоянного тока)CURRENTCORRIENTECOURANTCORRENTESTROMSTÄRKECORRENTE電流电流전류ТОКOPERATING TEMPERATURETEMPERATURA DE FUNCIONAMIENTOTEMPÉRATURE DE FONCTIONNEMENTTEMPERATURA OPERACIONALBETRIEBSTEMPERATURTEMPERATURA D’ESERCIZIO稼動温度操作温度작동 온도РАБОЧАЯ ТЕМПЕРАТУРАCABLE LENGTHLONG. DE CABLELONGUEUR DE CÂBLECOMPRIMENTO DO CABOCOMPRIMENTO DO CABOLUNGHEZZA CAVOケーブル長电缆长度케이블 길이ДЛИНА КАБЕЛЯUL REF NUMBERNÚMERO DE REFERENCIA ULRÉF. ULNÚMERO DE REFERÊNCIA ULUL-REFERENZNUMMERNUMERO DI RIFERIMENTO ULUL参照番号UL 参考编号UL 참조 번호Справочный номер в ULAVG PEAKRMK40 62305-16 VDC85 mA 120 mA-30° - 150°F(-35° - 65° C)Wiegand  =  500 ft   - 22 AWG    (152.4 m)    300 ft  -  24 AWG    (91.44 m)RMPK40Cx1x2NRMPK40 6236 ** 85 mA 169 mAUL Reference Number Decipheringx1  Reader Colors: K = Black, G = Grayx2  multiCLASS Proximity: N = HID/AWID ProxmultiCLASSM: RMK40 / RMPK40 INSTALLATION GUIDE6410-901, R A.1A 18, 2009© 2009 HID Global Corporation.  All rights reserved.15370 Barranca ParkwayIrvine, CA 92618-2215USA
multiCLASS RMK40 / RMPK406410-901 A.1 INSTALLATION GUIDE2©2009 HID Global Corporation. All rights reserved.1 Head Track AdjustmentsFor a credential with a different track position, change the head track position on the Magnetic Stripe reader. Snap out the head/gimbal assembly.1. Rotate the assembly 180 degrees.2. Re-install the assembly into the reader case.3. 2 MountingJunction box not included.Caja para conexiones no incluida.Boîtier de jonction non inclus.Caixa de junção não incluída.Anschlusskasten nicht mit inbegriffen.Scatola di raccordo non inclusa.不包括接线盒。接続ボックスは含まれていません。연결 박스는 제품에 포함되지 않습니다.Соединительная коробка не прилагаетсяWires away from reader faceWires toward reader face(default)
6410-901 A.1INSTALLATION GUIDE 3©2009 HID Global Corporation. All rights reserved.multiCLASSRMK40 / RMPK404 Install Reader to Backplate3 WiringAttach wire (see step 2) from the magnetic stripe reader to the iCLASS Keypad reader connector.ConnectorModule
hidglobal.comACCESS experience.North America15370 Barranca ParkwayIrvine, CA 92618USAPhone:   800 237 7769Support:   866 607 7339Fax:   949 732 2120Email:   tech@hidglobal.comAsia Pacific19/F 625 King’s RoadNorthPoint, Island EastHong KongPhone:   852 3160 9800Support:   852 3160 9833Fax:   852 3160 4809Email:   asiasupport@hidglobal.comEurope, Middle East & AfricaPhoenix RoadHaverhill, Suolk CB9 7AEEnglandPhone:   +44 1440 714 850Support:  +44 1440 711 822Fax:   +44 1440 714 840Email:   eusupport@hidglobal.comHID Global6410-901 Rev A.1Patent Pending© 2009 HID Global Corporation.  All rights reserved.Check reader label for current regulatory approvals.HID, HID Global, and iCLASS are the trademarks or registered trademarks of HID Global Corporation in the U.S. and other countries.ULConnect only to a Listed Access Control / Burglary power-limited power supply.  These readers are intended  to be used with listed (UL294) control equipment.Only the Wiegand communication protocol has been investigated by UL.FCC / Canada Radio CertificationThese devices comply with part 15 of the FCC rules. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.Le fonctionnement est soumis aux deux conditions suivantes : (1) Ce dispositif ne peut pas causer de perturbations nuisibles et (2) ce dispositif doit accepter toute perturbation quelconque qu’il reçoit, y compris des perturbations susceptibles de provoquer un fonctionnement indésirable. Les changements ou modifications n’ayant pas été expressément approuvés par la partie responsable de la conformité peuvent faire perdre à l’utilisateur l’autorisation de faire fonctionner le matériel.CE MarkingHID Global hereby declares that these proximity readers are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.Por el presente, HID Global declara que estos lectores de proximidad cumplen con los requisitos esenciales y otras disposiciones relevantes de la Directiva 1999/5/EC.HID Global déclare par la présente que ces lecteurs à proximité sont conformes aux exigences essentielles et aux autres stipulations pertinentes de la Directive 1999/5/CE.A HID Global, por meio deste, declara que estes leitores de proximidade estão em conformidade com as exigências essenciais e outras condições da diretiva 1999/5/EC.HID Global bestätigt hiermit, dass die Leser die wesentlichen Anforderungen und anderen relevanten Bestimmungen der Richtlinie 1999/5/EG erfüllen.HID Global dichiara che i lettori di prossimità sono conformi ai requisiti essenziali e ad altre misure rilevanti come previsto dalla Direttiva europea 1999/5/EC.Download copies of the R&TTE Declaration of Conformity (DoC) at http://certications.hidglobal.com.