HLI Solutions NXOFM1R1D Wireless Sensor Module User Manual

Hubbell Control Solutions Wireless Sensor Module

User Manual

Download: HLI Solutions NXOFM1R1D Wireless Sensor Module User Manual
Mirror Download [FCC.gov]HLI Solutions NXOFM1R1D Wireless Sensor Module User Manual
Document ID4069776
Application IDCDpO5ujQMhjR/nr0qc7iKw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize23.99kB (299843 bits)
Date Submitted2018-11-13 00:00:00
Date Available2018-11-13 00:00:00
Creation Date2018-10-10 13:01:55
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2018-10-10 13:01:56
Document TitleUser Manual
Document CreatorAdobe InDesign CC 13.1 (Macintosh)

NX™ ON-FIXTURE MODULE
INSTALLATION AND OPERATION INSTRUCTIONS
MODEL NUMBER
NXOFM
The Hubbell Control Solutions On-Fixture Module is intended to allow the installation of lighting controls to a single luminaire using a twist
lock receptacle that is accessible external to the fixture housing. The NXOFM requires a NEMA C136.41, 7-pin receptacle on the luminaire for
operation. The module contains a relay for on/off control, 0-10 volt dimming, a Bluetooth® radio for programming via an Android™ or iOS® App,
and a 2.4 GHz RF mesh radio with internal antenna.
INSTALLATION INSTRUCTIONS
1.
If applicable, remove the lighting control device currently installed in the fixture receptacle.
2.
Align the On-Fixture Module such that the large contact pin is positioned above the large receptacle contact.
3.
Insert the On-Fixture Module contacts completely into the receptacle contacts. Twist the On Fixture Module housing clockwise until it locks
into place.
4.
Test the On/Off and or dimming operation using the NX Room Setup Tool which is available for download from Google Play™ and
App Store®.
5.
Using the App, select the Bluetooth radio from the list of discovered radios. Use the MAC address barcode label affixed to the unit to help
identify the luminaire to be tested.
6.
Select Fixture Modules from the menu.
7.
Use the On/Off control to turn the luminaire on and off to confirm the operation.
8.
While the luminaire is on, use the slider to dim the luminaire down and up.
DIMENSIONS
3.9”
3.3”
NEMA C136.41 Receptacle
72-00603 Rev F
Page 1
701 Millennium Blvd. | Greenville, SC 29607 | (864) 678-1000 | (866) 898-0131 - fax www.hubbellcontrolsolutions.com
Copyright © 2018 Hubbell Control Solutions, a division of Hubbell Lighting, Inc. All rights reserved. All product and company names, logos and product
identifiers are trademarks ™ or registered trademarks ® of Hubbell Lighting, Inc. or their respective owners. Use of them does not necessarily imply any
affiliation with or endorsement by such respective owners.
3504B 100818
SPECIFICATIONS
RF Frequency
ISM 2.4GHz
RF Range
Up to 1000 ft (Clear Line of Sight)
Radio Performance
Radio Range: Indoor: ~300 ft. (~100m) Note: Actual range is dependent upon building construction and radio location
Outdoor: ~1000 ft. (~300m) Note: Range based on clear line of site.
Recommended Deployment Practices: Locate three radios within a 300 foot radius for most reliable performance
Electrical Ratings
Input: 120-480VAC, 16A Max, 50-60Hz
Output: 10A@120-277V, 5A@347V, 3A@480V
Surge Withstand: 2000V
Peak Inrush: 160A for 2 ms Max
Dimming
0-10V, 60mA, current sink
Daylight Sensor
On level: 1FC to 5FC (Default: 5FC)
Off level: 4FC to 15FC (Default: 8FC)
Operating Environment
Operating Temperature: -40°F to 176°F [-40°C to 80°C]
Relative humidity (non-condensing): 0 to 95%
IP65 Rated
Construction
Housing: GSM UL Rated 94 HB Plastic
Mounting
Standard NEMA C136-41 (2013) with 5 or 7 prongs twist lock connector also compatible with C136-10 sockets
Dimensions
3.125” D x 3.75” (79.4mm D x 95.3 H)
Weight
6 oz (170 g)
Color
Smoked plastic housing
Patents
Patent(s) pending
Certifications
Warranty
FCC:
RF safety statement
Observe a minimum safe distance of 20 cm from the device to the operator.
IC RF Exposure Statement / Déclaration d’exposition d’IC RF
Observe a minimum safe distance of 20 cm from the device to the operator.
Respectez une distance de sécurité minimale de 20 cm entre l’appareil et l’opérateur.
This device meets the IC requirements for RF exposure in public or uncontrolled environments.
Cet appareil est conforme aux conditions de la IC en matière de RF dans des environnements publics
ou incontrôlée.
Conforms with UL916 and Certified to CAN/CSA C22.2 No. 205-M1983
IC Approved
FCC Part 15.247: This device complies with FCC part 15 Rules.
Operation is subject to the following two conditions:
1.This device may not cause harmful interference and
2. This device must accept any interference received, including interference that may cause undesired operation
FCC ID: YH9NXOFM1R1D IC: 9044A-NXOFM1R1D
Contains FCC ID: U9O-SM220 IC: 7084A-SM220
FCC Interference Statement (Part 15.105 (b))
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
FCC Part 15 Clause 15.21: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
ISED RSS-Gen Notice:
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:
1.
This device may not cause interference; and
2.
This device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux
deux conditions suivantes:
1.
l’appareil ne doit pas produire de brouillage;
2.
l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
5-year limited
72-00603 Rev F
701 Millennium Blvd. | Greenville, SC 29607 | (864) 678-1000 | (866) 898-0131 - fax www.hubbellcontrolsolutions.com
Copyright © 2018 Hubbell Control Solutions, a division of Hubbell Lighting, Inc. All rights reserved. All product and company names, logos and product
identifiers are trademarks ™ or registered trademarks ® of Hubbell Lighting, Inc. or their respective owners. Use of them does not necessarily imply any
affiliation with or endorsement by such respective owners.
3504B 100818
WIRING DIAGRAM
72-00603 Rev F
Page 2
701 Millennium Blvd. | Greenville, SC 29607 | (864) 678-1000 | (866) 898-0131 - fax www.hubbellcontrolsolutions.com
Copyright © 2018 Hubbell Control Solutions, a division of Hubbell Lighting, Inc. All rights reserved. All product and company names, logos and product
identifiers are trademarks ™ or registered trademarks ® of Hubbell Lighting, Inc. or their respective owners. Use of them does not necessarily imply any
affiliation with or endorsement by such respective owners.
3504B 100818

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c143 79.161424, 2017/09/22-11:52:47
Create Date                     : 2018:10:10 13:01:55-04:00
Metadata Date                   : 2018:10:10 13:01:56-04:00
Modify Date                     : 2018:10:10 13:01:56-04:00
Creator Tool                    : Adobe InDesign CC 13.1 (Macintosh)
Instance ID                     : uuid:d53445c5-ed30-4541-9022-7a8d2b1122e2
Original Document ID            : xmp.did:288E08AB5B30E311BC9FD823177A3F22
Document ID                     : xmp.id:a9503079-1f5c-4818-b065-30106e021533
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:6115660e-0930-4ede-88ea-ce8360442e27
Derived From Document ID        : xmp.did:4972db2c-191c-435a-a5d7-fe594b6df122
Derived From Original Document ID: xmp.did:288E08AB5B30E311BC9FD823177A3F22
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 13.1 (Macintosh)
History Changed                 : /
History When                    : 2018:10:10 13:01:55-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 3
Creator                         : Adobe InDesign CC 13.1 (Macintosh)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: YH9NXOFM1R1D

Navigation menu