HON HAI PRECISION IND T07AW Wireless Router for ADSL User Manual
HON HAI Precision Ind. Co., Ltd. Wireless Router for ADSL Users Manual
Contents
- 1. USERS MANUAL
- 2. Users Manual
Users Manual
REV. 0.0 Engineering Requirement Specification of T07L022.00 Prepared by Reviewed by Humphrey Huang Approved by REV. 0.0 Contents 0. Revision History ......................................................................................................... 3 1. Introduction ................................................................................................................. 4 1.1 Referenced Documents ....................................................................................4 2. Hardware Requirements........................................................................................... 5 2.1 Overall Information .........................................................................................5 2.2 Detailed HW Information ................................................................................5 2.2.1 Generic assumptions ........................................................................5 2.2.2 ADSL requirements...........................................................................6 2.2.3 Ethernet interface requirements .....................................................7 2.2.4 Wireless interface requirements .....................................................7 2.2.5 LEDs....................................................................................................8 3. Software Requirements ............................................................................................ 9 4. Regulatory requirements .......................................................................................... 9 REV. 0.0 0. Revision History Date Revision Comment 2005/01/18 0.0 Initial released REV. 0.0 1. Introduction Project Name: T07L022.00 This documentation describes the Engineering Requirement Specification (ERS) of the ADSL CPE with four Ethernet interfaces and a Wireless interface using BRCM BCM6348 solution. 1.1 Referenced Documents [1] Specifications for Next-Generation xDSL Broadband Access Network, Chunghwa Telecom Co., Ltd. REV. 0.0 2. Hardware Requirements 2.1 Overall Information T07L022.00 for CHT 6th tender ADSL2+ CPE Four-port Ethernet MiniPCI interface for 802.11g WLAN 2.2 Detailed HW Information 2.2.1 Generic assumptions ADSL: BCM6348 Ethernet Switch: BCM5325E SDRAM: 16MB - (4M*16) * 2 pcs Flash: 4MB WLAN Interface: MiniPCI Standalone POTS Splitter/ Low-pass Filter REV. 0.0 2.2.2 ADSL requirements Standard: ITU-T G.992.5 (ADSL2+) ADSL physical performance requirements: REV. 0.0 2.2.3 Ethernet interface requirements The ATU-R shall provide four 10/100 Base-T auto-sensing and half/full duplex configurable Ethernet interfaces. The Ethernet interfaces for ATU-R shall be able to operate well simultaneously. The 10/100 Base-T Ethernet interface shall comply with the IEEE 802.3/IEEE 802.3u, respectively. 2.2.4 Wireless interface requirements Transmitter: Max. output power shall be ≧ 15mW, 30mW, 60mW, as an option and will be selected in procurement specification. Receiver: REV. 0.0 2.2.5 LEDs Shall provide different status indicators on the front panel. (1) Power, (2) Alarm, (3) LAN Connectivity for each LAN port, (4) LAN Data Transmit/Receive for each LAN port, (5) Line Synchronization, including retraining phase and in-synchronization, (6) Line interface Data Transmit/Receive, (7) Wireless Connectivity and Data Transmit/Receive. REV. 0.0 3. Software Requirements Follow the requirements of [1]. 4. Regulatory requirements Suitable protection devices in compliance with IEC 61000-4-5 class 3 at least or FCC part 68 shall be provided on the line interfaces, the POTS splitter/ Low-pass filter, and AC power supply lines to safeguard the unit against the damage due to transient and lightning surge voltage presented on the telephone line and AC power supply line. The test results of IEC 61000-4-5 can be temporary degradation or loss of function or performance but must be self-recoverable and pass operationally within 10 minutes. To fulfill surge protection in easy-installation manner, the ATU-R must incorporate with chassis grounding mechanism on the exterior of device. The electromagnetic compatibility requirements of the ATU-R shall comply with class A of EN55022 of the CENELEC (the European Committee for Electrotechnical Standardization), or class A of 22 of the CISPR (International Special Committee on Radio Interference of the International Electrotechnical Commission) or class A of Subpart B of Part 15 of the FCC (Federal Communications Commission) rules of U.S.A. REV. 0.0 Engineering Requirement Specification of T07L022.01 Prepared by Reviewed by Devin Shyr Humphrey Huang Approved by REV. 0.0 Contents 0. Revision History.................................................................................................... 3 1. Introduction ................................................................................................................. 4 1.1 Referenced Documents ....................................................................................4 2. Hardware Requirements........................................................................................... 5 2.1 Overall Information .........................................................................................5 2.2 Detailed HW Information ................................................................................5 2.2.1 Generic assumptions ........................................................................5 2.2.2 ADSL requirements ...........................................................................6 2.2.3 Ethernet interface requirements......................................................7 2.2.4 LEDs....................................................................................................7 3. Software Requirements ............................................................................................ 8 4. Regulatory requirements .......................................................................................... 8 REV. 0.0 0. Revision History Date Revision Comment 2005/07/19 0.0 Initial released REV. 0.0 1. Introduction Project Name: T07L022.01 This documentation describes the Engineering Requirement Specification (ERS) of the ADSL CPE with four Ethernet interfaces. 1.1 Referenced Documents [1] Specifications for Next-Generation xDSL Broadband Access Network, Chunghwa Telecom Co., Ltd. REV. 0.0 2. Hardware Requirements 2.1 Overall Information T07L022.01 for CHT 6th tender ADSL2+ CPE Four-port Ethernet 2.2 Detailed HW Information 2.2.1 Generic assumptions ADSL: BCM6348 Ethernet Switch: BCM5325E SDRAM: 16MB - (4M*16) * 1 pcs Flash: 2MB Standalone POTS Splitter/ Low-pass Filter REV. 0.0 2.2.2 ADSL requirements Standard: ITU-T G.992.5 (ADSL2+) ADSL physical performance requirements: REV. 0.0 2.2.3 Ethernet interface requirements The ATU-R shall provide four 10/100 Base-T auto-sensing and half/full duplex configurable Ethernet interfaces. The Ethernet interfaces for ATU-R shall be able to operate well simultaneously. The 10/100 Base-T Ethernet interface shall comply with the IEEE 802.3/IEEE 802.3u, respectively. 2.2.4 LEDs Shall provide different status indicators on the front panel. (1) Power, (2) Alarm, (3) LAN Connectivity for each LAN port, (4) LAN Data Transmit/Receive for each LAN port, (5) Line Synchronization, including retraining phase and in-synchronization, (6) Line interface Data Transmit/Receive, REV. 0.0 3. Software Requirements Follow the requirements of [1]. 4. Regulatory requirements Suitable protection devices in compliance with IEC 61000-4-5 class 3 at least or FCC part 68 shall be provided on the line interfaces, the POTS splitter/ Low-pass filter, and AC power supply lines to safeguard the unit against the damage due to transient and lightning surge voltage presented on the telephone line and AC power supply line. The test results of IEC 61000-4-5 can be temporary degradation or loss of function or performance but must be self-recoverable and pass operationally within 10 minutes. To fulfill surge protection in easy-installation manner, the ATU-R must incorporate with chassis grounding mechanism on the exterior of device. The electromagnetic compatibility requirements of the ATU-R shall comply with class A of EN55022 of the CENELEC (the European Committee for Electrotechnical Standardization), or class A of 22 of the CISPR (International Special Committee on Radio Interference of the International Electrotechnical Commission) or class A of Subpart B of Part 15 of the FCC (Federal Communications Commission) rules of U.S.A.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-702 Modify Date : 2008:07:15 10:58:47+08:00 Create Date : 2008:07:15 10:57:37+08:00 Metadata Date : 2008:07:15 10:58:47+08:00 Format : application/pdf Document ID : uuid:bf0ddfb3-3104-4f62-8b52-4bdc913ecf8b Instance ID : uuid:780a026e-cd30-4cf1-b4fd-27c3a588b229 Producer : Acrobat Distiller 5.0.5 (Windows) Has XFA : No Page Count : 17EXIF Metadata provided by EXIF.tools