HOSEOTELNET ATM200 Reflex Module User Manual ATM200 REV01

Hoseo Telnet Co., Ltd. Reflex Module ATM200 REV01

User Manual

Download: HOSEOTELNET ATM200 Reflex Module User Manual ATM200  REV01
Mirror Download [FCC.gov]HOSEOTELNET ATM200 Reflex Module User Manual ATM200  REV01
Document ID544604
Application IDeOL8NiqLWOc2VUysvHgYLw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize27.23kB (340325 bits)
Date Submitted2005-05-20 00:00:00
Date Available2005-05-20 00:00:00
Creation Date2005-05-12 12:22:29
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2005-05-12 12:22:29
Document TitleMicrosoft Word - ATM200_User Manual_REV01.doc
Document CreatorPScript5.dll Version 5.2
Document Author: Y. G. Gwon

Hoseo Telnet ReFLEX Module
User manual
User Manual
The ReFLEX Module
(ATM 200)
ReFLEX Module
1/13
Tel 02 ) 2659 - 7345
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Hoseo Telnet ReFLEX Module
User manual
Content
1. Description
2. Outline and Function
2.1 Outline
2.2 Description of 14 pin
Connector
2.3 Sub Board & Data Link Cable
2.4 Package
3. Configure the ReFLEX Module – PPS 3.1 logon
3.2 List
3.3 Control
4. Message receiving and sending
4.1 ATM200
4.1.1 Message sending
4.1.2 Message receiving
HOW TO SET “REFLEX” TWO WAY RADIO MODULE.
ReFLEX Module
2/13
Tel 02 ) 2659 - 7345
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Hoseo Telnet ReFLEX Module
User manual
1. Description
● System Block Diagram
System
ReFLEX
Device
ReFLEX
Host
Device
CLP Serial
Interface
Carrier's System
< Drawing 1. ReFLEX system Block Diagram >
- ReFLEX : The communication protocol between Carrier’s system and ReFLEX device or module
through ReFLEX network.
- CLP Serial Interface : It is communication
Linking Protocol (CLP), it enable the wire
communication between ReFLEx device or module
and Host device through
the
Serial Interface.
● Message receiving and sending
The Message receiving and sending is possible by pc program ( HSM8800 v1.3) which
support the CLP serial interface even thought there is no Host device.
Refer to CLP reference manual for more information for serial interface of
Communication Linking Protocol (CLP).
● Configure the ReFLEX Module
The configuration of ReFLEX Module will be done by PC based program ( PPS).
ReFLEX Module
3/13
Tel 02 ) 2659 - 7345
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Hoseo Telnet ReFLEX Module
User manual
2. Outline and Function
2.1 ReFLEX Module Outline
< Drawing 2. ReFLEX Module >
The interface between ReFLEX Module and Host Device will be done by 14 pin connector.
ReFLEX Module
4/13
Tel 02 ) 2659 - 7345
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Hoseo Telnet ReFLEX Module
User manual
2.2 Description of 14 pin connector
< Drawing 3
10
11
12
13
14
14 pin connector >
Pin Configuration
PIN
Name
Type
Description
VCC_Tx
VCC_Main
GPIO0
CMOS, General Purpose I/O
GPIO1
CMOS, General Purpose I/O
SI0
Reserved, NC
SO0
Reserved, NC
SCK0
Reserved, NC
VCC
Reserved, NC
GND
Signal Ground
10
Tx_Data
UART Output
11
Rx_Data
UART Input
12
Enable
Module Enable
13
VPP
Reserved, NC
14
GND
Signal Ground
4V~10V, 3A, PA Voltage
4V~10V,200mA, Controller Voltage
*Note :CMOS Level 3V
< Table 1 pin description >
ReFLEX Module
5/13
Tel 02 ) 2659 - 7345
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Hoseo Telnet ReFLEX Module
User manual
2.3 Sub Board & Data Link Cable
< Drawing 4 Sub Board >
1) Sub Board :
The sub board will supply the power to module and it will be used for parameter setting (PPS)
and data receiving and sending by PC. If you apply the DC 4-10V to power terminal, then
module will be activated.
The communication with PC will be able to by specific data link cable which supplied by module
supplier.
< Drawing5. Data Link Cable >
ReFLEX Module
6/13
Tel 02 ) 2659 - 7345
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Hoseo Telnet ReFLEX Module
User manual
2) Data Link Cable :
It will be used for communication between ReFLEX Module and PC through Sub Board.
The
data link cable, which is being supplied by ATM200 supplier, incorporated the RS232C
converter, then you can communicate with PC without additional peripherals.
2.4 Package
< Dwaring6.
Package >
ReFLEX Module
7/13
Tel 02 ) 2659 - 7345
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Hoseo Telnet ReFLEX Module
● Pre caution for Module(ATM 200)
User manual
interface
The serial communication default speed is being set as 9600BPS, if you can change it CLP
command.
Module (ATM 200) has a power save mode function, then you must wake up the module
whenever you are to use it. The wake up time is 20ms, and if you are to wake up the
module, send the CLP command 0x19.
After the reset, the module will not goes to power save mode for 60 seconds, then you can
do the parameter setting during that time by PPS program.
● Module Operation Description
If you apply the power, the LED will be On and Off.
‘P’ LED will be “ON” when the Module synchronized to network.
‘T’ LED will be “ON” when Module is transmitting a data..
LED can be disabled by command.
3. Configure the ReFLEX Module – PPS Please refer to PPS manual for more details.
3.1 Logon
< Drawing7 Log on >
Key in the default pass word ‘HSTMAST’.
ReFLEX Module
8/13
Tel 02 ) 2659 - 7345
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Hoseo Telnet ReFLEX Module
User manual
3.2 List
< Drawing8 List >
- Global Scan List : Rx frequency setting(if Space is set Spacing is 10KHz)
- IS Address : Information Service address
- SPID : Service Provide ID
- Personal Address : Cap code
- Else : refer to PPS user’s guide
- Menu Description
① Export : Store the PPS Parameter file.
② Import : Reading the PPS Parameter file.
③ Download : Download the data to REFLEX Module.
④ Personal Address : Put in the ReFLEX Module MSN.
ReFLEX Module
9/13
Tel 02 ) 2659 - 7345
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Hoseo Telnet ReFLEX Module
User manual
3.3 Control
< Drawing9 Control >
- Power Level(mW) : RF Power Output
- PPS password : PPS login password
ReFLEX Module
10/13
Tel 02 ) 2659 - 7345
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Hoseo Telnet ReFLEX Module
User manual
4. Message Sending and Receiving
If there is no Host device, you can send and receive the message through PC.
The firmware , HSM8800 make you to sending and receiving the message , and you can also
check the functionality of AT 200.
4.1 HSM8800
< Drawing10. HSM8800 CLP Communicator v1.3
ReFLEX Module
11/13
Tel 02 ) 2659 - 7345
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Hoseo Telnet ReFLEX Module
User manual
4.1.1 Message Sending
Sending the message to destination..
< Drawing11. BMO Message Send >
① Address Type : There are two(2) address type “P” and “E”
Address Type
Description
Send the message using PIN number of ReFLEX Module.
(Ex. : 3071297 )
Sending the message using email address.
( Ex. : hjino5@hoseo.or.kr )
< Table2. Address Type >
② Address : key in the address of receiving part.
③ ReFLEX Test Message: key in the sending message.
④ Send : Click the “Send” button to send the message..
4.1.2 Message receiving
Download the received message on ReFLEX Module.
< Drawing12. Download MSG >
① Click the “Send” button to download the received message.
ReFLEX Module
12/13
Tel 02 ) 2659 - 7345
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Hoseo Telnet ReFLEX Module
User manual
HOW TO SET ReEFLEX” TWO WAY RADIO MODULE.
- Check the power source , 4~10V and 3A
- Soldering the Shield Case to Ground
- Connect the 50 ohm antenna to SMA connector of module
*Do not operate the module without Antenna
- Apply the power and Interface
*Remark
- Do not change the trimmer set on case
- Do not open the shield case, In this case a warranty conditions will be invalid.
NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE
CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS
COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
“CAUTION: Exposure to Radio Frequency Radiation.
Antenna shall be mounted in such a manner to minimize the potential for human contact during normal
operation. The antenna should not be contacted during operation to avoid the possibility of exceeding the FCC
radio frequency exposure limit. The minimum separation distance of 20cm from the antenna to the body of user
required.”
ReFLEX Module
13/13
Tel 02 ) 2659 - 7345
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Create Date                     : 2005:05:12 12:22:29+09:00
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2005:05:12 12:22:29+09:00
Format                          : application/pdf
Title                           : Microsoft Word - ATM200_User Manual_REV01.doc
Creator                         : Y. G. Gwon
Document ID                     : uuid:b781fbb2-cc8e-4df0-9995-2aced6c01551
Instance ID                     : uuid:6e138d4b-283a-408c-b449-172e2eacc984
Page Count                      : 13
Author                          : Y. G. Gwon
EXIF Metadata provided by EXIF.tools
FCC ID Filing: R2SATM200

Navigation menu