Hager 5300_p1,5 6_11 3 05 5300 Series Door Closer Installation Instructions Pg1 6 8 14 06 1
User Manual: Hager 5300 Series Door Closer Installation Instructions Installation Instructions
Open the PDF directly: View PDF .
Page Count: 6
Download | |
Open PDF In Browser | View PDF |
5300 Series Door Closer Installation Instructions Grade 1 Meets ANSI A156.4 An incorrectly installed or improperly adjusted door closer can cause property damage or personal injury. These installation instructions should be followed to avoid the possibility of misapplication or misadjustment. Regular Arm Installation See Page 2 Left Hand Door - LH Right Hand Reverse - RHR Parallel Arm Installation See Pages 3&4 Left Hand Door - LH Right Hand Reverse - RHR Regular Arm Installation See Page 2 NOTE: For special applications, a separate door and frame preparation template is packed with these instructions. Use this instruction sheet for installation sequence and closer adjustments only. • Dimensions are based on standard doors and frames with 1/8" clearance, 5/8" stops, and square edge doors. • Door and frame must be properly reinforced. • Non-Handed Door Closers. Parallel Arm Installation See Pages 3&4 Right Hand Door - RH Left Hand Reverse - LHR NOTE: For Top Jamb Application Top Jamb Installation See Page 5 Top Jamb Installation See Page 5 A longer connecting rod is required for Reveal reveals greater than 4" (102mm) Left Hand Door - LH Right Hand Reverse - RHR Right Hand Door - RH Left Hand Reverse - LHR Right Hand Door - RH Left Hand Reverse - LHR • These door closers should NOT be installed on the exposed side (weather side) of exterior doors. TOOLS REQUIRED WOOD METAL Self Drilling Screws Wood and Metal For wood, drill 3/16" hole Sleeve Nut and Bolt Drill 9/32" thru from Closer Side 3/8" Drill other Side Machine Screws #7 3/16" #7 Drill, 1/4"- 20 Tap 1/4"- 20 Check building and fire codes to see if your application requires the use of sleeve nuts and bolts. COMPONENT PARTS POWER ADJUSTMENT SHAFT REGULAR ARM/TOP JAMB SHOE MAIN ARM LATCH VALVE INSERT CUTOUT BACKCHECK VALVE SCREW PACK FOREARM SCREW CLOSER BODY SWEEP VALVE PARALLEL ARM BRACKET CONNECTING ROD CLOSER ARM CLOSER COVER PINION CAP HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149 5300 Series Non-Hold Open Door Closer - Regular Arm Installation Instructions Meets ANSI A156.4 1. PARTS 2. MARK AND DRILL HOLES (Right Hand Shown) A 1-1/4" (32mm) 6" (152mm) 1-3/4" (44mm) Door Opening Dimension “A” To 100 7" (178mm) 101 to 120 6" (152mm) 121 to *180 3-1/2" (89mm) 3/4" (19mm) 1" (25mm) 9-1/16" (230mm) *Door/Wall/Hardware/Jamb conditions permitting Speed regulating valves toward hinge edge. 3. INSTALL CLOSER Select hand of door and degree of door opening. Fold template on the corresponding line for desired degree of door opening and hand. Match this line with the hinge edge of door and attach template to door. Be sure frame line on template lines up with the bottom edge of frame face. Mark, prep and drill/tap 1/4" - 20 holes for closer body and jamb shoe mounting screws. 4. INSTALL MAIN ARM 5. INSTALL MAIN ARM AND CONNECTING ROD FRAME RIGHT HAND DOOR 90˚ RIGHT ANGLE L R H PINION FLAT POSITION OF MAIN ARM WHEN ASSEMBLING TO SPINDLE Remove template and use mounting screws to install the closer body to the door and the jamb shoe to the frame. Closer body should be oriented so that the speed regulating valves are toward the hinge stile of door. Orient main arm so that the “H”, located on the main arm, lines up with the flat on the spindle. Press arm down on spindle and secure with spindle bolt. 6. OPTIONAL HOLD-OPEN ARM 7. ADJUSTMENTS 8. INSTALL COVER / PINION CAP See Adjustments on Page 6 for setting Spring Power, Sweep Speed, Latch Speed, and Backcheck. S Identify direction of hold-open nut according to hand of door and mount arm. Slide connecting rod into forearm of main arm. Rotate main arm until connecting rod is at a 90˚ angle to frame. While holding arm in this position, tighten down forearm screw. L NOTE: Do not fully unscrew valves or hydraulic fluid will leak and closer will no longer be functional. COVER Press pinion cap onto un-used closer body spindle. If installing cover instead of pinion cap, slide cover over closer body and secure by tightening screws. Adjust by loosening hold-open nut, then open door to desired position and tighten hold-open nut securely. HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149 2 PINION CAP 5300 Series Non-Hold Open Door Closer - Parallel Arm Installation Instructions Meets ANSI A156.4 1. PARTS 2. MARK AND DRILL HOLES (Right Hand Shown) 2-3/4" (70mm) 3/8" A (10mm) (Center on Hinge) B 2" (51mm) Top of Door 1/2" (13mm) 7/16" (11mm) Select hand of door and the degree of door opening. Fold template on the corresponding line for desired degree and hand. Fold or cut upper corner illustrated on template and align template with the hinge edge of door. At the “Frame Stop Line” fold toward you and attach template to door. Mark, prep and drill/tap 1/4"-20 holes for closer body and parallel arm bracket mounting screws. Frame 3" (76mm) Door Opening To 100 101 to 130 Over 131 9-1/4" 7-5/8" (235mm) (194mm) 7-3/4" 6-1/8" 197mm) (156mm) 5-3/4" 4-1/8" (146mm) (105mm) 3. INSTALL CLOSER 3/4" (19mm) 9-1/16" (230mm) (Center on Hinge) Speed regulating valves toward lock stile. 4. INSTALL CONNECTING ROD Remove template and use mounting screws to install the closer body to the door and the parallel arm bracket to the frame soffit. Closer body should be oriented so that the speed regulating valves are toward the lock stile of door. CONNECTING ROD For parallel arm application only, remove regular arm / top jamb shoe. Attach connecting rod to the parallel arm plate. 5. INSTALL MAIN ARM Ro tate 45 ˚ Use adjustable wrench to rotate spindle 45˚ counterclockwise for Right Hand Door or clockwise for Left Hand Door. Place main arm on spindle so that the “R” (Right Hand Door) or “L” (Left Hand Door) lines up with the spindle flat. Secure main arm and spindle by tightening spindle bolt. HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149 3 5300 Series Non-Hold Open Door Closer - Parallel Arm Installation Instructions Meets ANSI A156.4 6. INSTALL MAIN ARM AND CONNECTING ROD a) Slide connecting rod into forearm of main arm. b) c) 1-1/2" (38mm) 1-1/2" (38mm) While holding arm in this position, tighten down forearm screw. Rotate main arm until the pivot point is 1-1/2" from door surface. 7. OPTIONAL HOLD-OPEN ARM Identify direction of hold-open nut according to hand of door and mount arm. 8. ADJUSTMENTS See Adjustments on Page 6 for setting Spring Power, Sweep Speed, Latch Speed, and Backcheck. 9. INSTALL COVER / PINION CAP COVER L S NOTE: Do not fully unscrew valves or hydraulic fluid will leak and closer will no longer be functional. Press pinion cap onto un-used closer body spindle. If installing cover instead of pinion cap, slide cover over closer body and secure by tightening screws. PINION CAP Adjust by loosening hold-open nut, then open door to desired position and tighten hold-open nut securely. HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149 4 5300 Series Door Closer - Top Jamb Arm Installation Instructions Meets ANSI A156.4 1. PARTS 2. MARK AND DRILL HOLES (Right Hand Shown) 9-1/16" (230mm) 3/4" (19mm) A Top of Frame 1-3/4" (44mm) 1-3/4" (44mm) 6" (152mm) Dimension “A” To 100 7-1/2" (191mm) 101 to 120 6" (152mm) 121 to *180 3-1/2" (89mm) *Door/Wall/Hardware/Jamb conditions permitting 1/2" (13mm) A longer connecting rod is required for Reveal reveals greater than 4" (102mm) Speed regulating valves toward hinge edge. 3. INSTALL CLOSER Door Opening Select hand of door and the degree of door opening. Separate template sections “A” and “B”. Fold template on the corresponding line for desired degree and hand. Match this line with the hinge edge of door and attach template to door. Be sure “Frame” line on template lines up with the top edge of door. Using a square, project “Closer Projection Line” on section “A” of template onto frame and use to align and attach section “B”. Be sure to align bottom edge of section “B” with edge of frame. Mark, prep and drill/tap 1/4"- 20 holes for connecting rod shoe and closer body mounting screws. 4. INSTALL MAIN ARM 5. INSTALL MAIN ARM AND CONNECTING ROD RIGHT HAND DOOR MAIN ARM FRAME CONNECTING ROD 90˚ RIGHT ANGLE L R H PINION FLAT POSITION OF MAIN ARM WHEN ASSEMBLING TO SPINDLE 6. OPTIONAL HOLD-OPEN ARM Orient main arm so that the “H”, located on the main arm, lines up with the flat on the spindle. Press arm down on spindle and secure with spindle bolt. 7. ADJUSTMENTS See Adjustments on Page 6 for setting Spring Power, Sweep Speed, Latch Speed, and Backcheck. Slide connecting rod into forearm of main arm. Rotate main arm until connecting rod is at a 90˚ angle to frame. While holding arm in this position, tighten down forearm screw. 8. INSTALL COVER / PINION CAP PINION CAP COVER L Identify direction of hold-open nut according to hand of door and mount arm. MAIN ARM S Remove template and use mounting screws to install the closer body to the top jamb and the connecting rod shoe to the door. Closer body should be oriented so that the speed regulating valves are toward the hinge stile of door. NOTE: Do not fully unscrew valves or hydraulic fluid will leak and closer will no longer be functional. Press pinion cap onto un-used closer body spindle. If installing cover instead of pinion cap, slide cover over closer body and secure by tightening screws. Adjust by loosening hold-open nut, then open door to desired position and tighten hold-open nut securely. HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149 5 5300 Series Door Closer - Adjustments Installation Instructions Meets ANSI A156.4 ADJUSTMENTS (USE 5/32" HEX WRENCH FOR THESE ADJUSTMENTS) SWEEP SPEED L LATCH SPEED L S + BACKCHECK S OPTIONAL DELAY ACTION BC + + S L Note: Adjust closing time speed to between 3 and 7 seconds from 90˚ to 0˚. Greater closing times may be required for elderly or handicapped. Adjust latch speed so door completely closes and latches. Adjust delay action accordingly to obtain desired delay time. Adjust backcheck accordingly to prevent excessive opening speed. SPRING POWER ADJUST (Sizing in accordance to BHMA/ANSI 156.4) TABLE OF SIZES Closer is shipped set to size 3. To change the closer size, use a hex wrench to rotate the spring power adjust. Follow the chart to make the correct numbers of 360° turns to set the closer size appropriately for the door application. Exterior (and Vestibule) Door Width Minimum Door Width (24") 24" - 30" - 36" - 42" - 48" (610mm) (762mm) (914mm) (1067mm) (1219mm) Regular Arm & Top Jamb Parallel Arm Size 3 (0) Size 4 Size 5 Size 6 (5cw) (10cw) (15cw) Size 3 Size 4 Size 5 (5cw) (10cw) (15cw) Interior Door Width BC The number of turns is an approximation and does not account for environmental or door hardware affects. Approx. 5 turns to increase / decrease one size. (Use 5/32" Hex Wrench for this adjustment) cw = clockwise ccw = counterclockwise Minimum Door Width (24") 24" - 30" - 34" - 38" - 48" - Regular Arm & Size 1 Size 2 Top Jamb (10ccw) (5ccw) Parallel Arm Size 1 Size 2 (5ccw) (0) Size 3 (0) Size 4 Size 5 Size 6 (5cw) (10cw) (15cw) Size 3 Size 4 Size 5 (5cw) (10cw) (15cw) ARM PLACEMENT IN SHOE ADJUSTMENT DIAGRAM 7-1/2% Stronger Y DELA or or 7-1/2% Weaker HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149 6 54" - 60" (610mm) (762mm) (865mm) (965mm) (1219mm) (1372mm) (1524mm)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : rwilkins Create Date : 2006:08:14 15:46:38-05:00 Modify Date : 2012:06:12 15:54:56-05:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 6.0 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2012:06:12 15:54:56-05:00 Document ID : uuid:6c18c9e9-2a29-4c6d-8f92-840eb2df9913 Instance ID : uuid:cb5304e5-f0f6-e84d-88f8-ff828a273b1a Format : application/pdf Title : 5300_p1,5-6_11-3-05.ai Creator : rwilkins Page Count : 6EXIF Metadata provided by EXIF.tools