Hager 5300_p1,5 6_11 3 05 5300 Series Door Closer Installation Instructions Pg1 6 8 14 06 1

User Manual: Hager 5300 Series Door Closer Installation Instructions Installation Instructions

Open the PDF directly: View PDF PDF.
Page Count: 6

BACKCHECK VALVE
CLOSER BODY
PARALLEL
ARM BRACKET
POWER ADJUSTMENT SHAFT REGULAR ARM/TOP
JAMB SHOE
CONNECTING ROD
INSERT CUTOUT
FOREARM
SCREW
SCREW PACK
MAIN ARM
CLOSER ARM
PINION CAP
CLOSER COVER
LATCH VALVE
SWEEP VALVE
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149
TOOLS REQUIRED
COMPONENT PARTS
METAL
1/4"- 20
#7 3/16"
WOOD Self Drilling Screws
Wood and Metal
For wood, drill 3/16" hole
Sleeve Nut and Bolt
Drill 9/32" thru from Closer Side
3/8" Drill other Side
Machine Screws
#7 Drill, 1/4"- 20 Tap
An incorrectly installed or
improperly adjusted door closer
can cause property damage or
personal injury. These installation
instructions should be followed
to avoid the possibility of
misapplication or misadjustment.
NOTE: For special applications, a separate door
and frame preparation template is packed with
these instructions. Use this instruction sheet for
installation sequence and closer adjustments only.
Dimensions are based on standard doors and
frames with 1/8" clearance, 5/8" stops, and
square edge doors.
Door and frame must be properly reinforced.
Non-Handed Door Closers.
• These door closers should NOT be installed on the exposed side (weather side) of exterior doors.
Regular Arm
Installation
See Page 2
Left Hand Door - LH
Right Hand Reverse - RHR
Regular Arm
Installation
See Page 2
Right Hand Door - RH
Left Hand Reverse - LHR
Top Jamb
Installation
See Page 5
Top Jamb
Installation
See Page 5
NOTE: For Top Jamb
Application
Left Hand Door - LH
Right Hand Reverse - RHR
Right Hand Door - RH
Left Hand Reverse - LHR
Parallel Arm
Installation
See Pages
3 & 4
Parallel Arm
Installation
See Pages
3 & 4
Left Hand Door - LH
Right Hand Reverse - RHR
Right Hand Door - RH
Left Hand Reverse - LHR
A longer connecting
rod is required for
reveals greater
than 4" (102mm)
Reveal
5300 Series Door Closer
Installation Instructions
Grade 1
Meets ANSI A156.4
Check building and fire codes to
see if your application requires
the use of sleeve nuts and bolts.
FRAME
WHEN ASSEMBLING TO SPINDLE
PINION FLAT
L
H
R
POSITION OF MAIN ARM
RIGHT HAND DOOR
90˚ RIGHT ANGLE
1-1/4"
(32mm)
1-3/4"
(44mm)
1"
(25mm)
9-1/16"
(230mm)
6"
(152mm)
3/4"
(19mm)
A
LS
1. PARTS
3. INSTALL CLOSER
2. MARK AND DRILL HOLES (Right Hand Shown)
4. INSTALL MAIN ARM 5. INSTALL MAIN ARM AND
CONNECTING ROD
7. ADJUSTMENTS 8. INSTALL COVER / PINION CAP
COVER
PINION CAP
Select hand of door and degree
of door opening. Fold template
on the corresponding line for
desired degree of door opening
and hand. Match this line with
the hinge edge of door and
attach template to door. Be sure
frame line on template lines up
with the bottom edge of frame
face. Mark, prep and drill/tap
1/4" - 20 holes for closer body
and jamb shoe mounting screws.
Remove template and use mounting screws
to install the closer body to the door and the
jamb shoe to the frame. Closer body should
be oriented so that the speed regulating valves
are toward the hinge stile of door.
Press pinion cap onto un-used closer
body spindle. If installing cover instead
of pinion cap, slide cover over closer
body and secure by tightening screws.
Orient main arm so that the “H”, located on
the main arm, lines up with the flat on the
spindle. Press arm down on spindle and
secure with spindle bolt.
Slide connecting rod into forearm of main arm.
Rotate main arm until connecting rod is at a
90˚ angle to frame. While holding arm in this
position, tighten down forearm screw.
Door Opening Dimension “A”
To 100 7"
(178mm)
6"
(152mm)
3-1/2"
(89mm)
101 to 120
121 to *180
*Door/Wall/Hardware/Jamb
conditions permitting
Speed regulating valves toward hinge edge.
5300 Series Non-Hold Open Door Closer - Regular Arm
Installation Instructions
Meets ANSI A156.4
2
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149
6. OPTIONAL HOLD-OPEN ARM
See Adjustments on Page 6
for setting Spring Power,
Sweep Speed, Latch Speed,
and Backcheck.
NOTE: Do not fully unscrew valves or
hydraulic fluid will leak and closer will no
longer be functional.
Identify direction of hold-open nut according to hand
of door and mount arm.
Adjust by loosening hold-open nut, then open door
to desired position and tighten hold-open nut
securely.
R
o
t
a
t
e
4
5
˚
3"
(76mm)
3/4"
(19mm) 9-1/16"
(230mm)
Top of
Door
B
Frame
(Center on Hinge)
(Center on Hinge)
2-3/4"
(70mm)
7/16"
(11mm)
2"
(51mm)
A
3/8"
(10mm)
1/2"
(13mm)
Speed regulating valves toward lock stile.
CONNECTING ROD
1. PARTS
3. INSTALL CLOSER
2. MARK AND DRILL HOLES (Right Hand Shown)
4. INSTALL CONNECTING ROD
5. INSTALL MAIN ARM
Select hand of door and the degree of door
opening. Fold template on the corresponding line
for desired degree and hand. Fold or cut upper
corner illustrated on template and align template
with the hinge edge of door. At the “Frame Stop
Line” fold toward you and attach template to door.
Mark, prep and drill/tap 1/4"-20 holes for closer
body and parallel arm bracket mounting screws.
Use adjustable wrench to rotate spindle 45˚ counterclockwise for Right Hand
Door or clockwise for Left Hand Door. Place main arm on spindle so that the
“R” (Right Hand Door) or “L” (Left Hand Door) lines up with the spindle flat.
Secure main arm and spindle by tightening spindle bolt.
Remove template and use
mounting screws to install the
closer body to the door and
the parallel arm bracket to
the frame soffit. Closer body
should be oriented so that the
speed regulating valves are
toward the lock stile of door.
For parallel arm application only, remove regular arm /
top jamb shoe. Attach connecting rod to the parallel
arm plate.
5300 Series Non-Hold Open Door Closer - Parallel Arm
Installation Instructions
Meets ANSI A156.4
3
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149
Door Opening
To 100
101 to 130
9-1/4"
(235mm)
7-5/8"
(194mm)
7-3/4"
197mm)
6-1/8"
(156mm)
Over 131 5-3/4"
(146mm)
4-1/8"
(105mm)
LS
6. INSTALL MAIN ARM AND CONNECTING ROD
9. INSTALL COVER / PINION CAP
Slide connecting rod into forearm of main arm.
Rotate main arm until the pivot point is 1-1/2" from door surface. While holding arm in this position, tighten down forearm screw.
5300 Series Non-Hold Open Door Closer - Parallel Arm
Installation Instructions
Meets ANSI A156.4
a)
b) c)
4
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149
1-1/2"
(38mm)
1-1/2"
(38mm)
COVER
PINION CAP
Press pinion cap onto
un-used closer body spindle.
If installing cover instead of
pinion cap, slide cover over
closer body and secure by
tightening screws.
8. ADJUSTMENTS7. OPTIONAL HOLD-OPEN ARM
See Adjustments on Page 6
for setting Spring Power,
Sweep Speed, Latch Speed,
and Backcheck.
NOTE: Do not fully unscrew valves or
hydraulic fluid will leak and closer will no
longer be functional.
Identify direction of hold-open nut according to hand
of door and mount arm.
Adjust by loosening hold-open nut, then open door
to desired position and tighten hold-open nut
securely.
9-1/16"
(230mm)
Top of
Frame
A
3/4"
(19mm)
1/2"
(13mm)
1-3/4"
(44mm)
1-3/4"
(44mm)
6"
(152mm)
L
H
R
LS
1. PARTS
3. INSTALL CLOSER
2. MARK AND DRILL HOLES (Right Hand Shown)
4. INSTALL MAIN ARM 5. INSTALL MAIN ARM AND
CONNECTING ROD
8. INSTALL COVER / PINION CAP
COVER
MAIN ARM
CONNECTING
ROD
MAIN ARM
PINION CAP
Select hand of door and the degree of door
opening. Separate template sections “A” and
“B”. Fold template on the corresponding line
for desired degree and hand. Match this line
with the hinge edge of door and attach template
to door. Be sure “Frame” line on template lines
up with the top edge of door. Using a square,
project “Closer Projection Line” on section “A”
of template onto frame and use to align and
attach section “B”. Be sure to align bottom
edge of section “B” with edge of frame. Mark,
prep and drill/tap 1/4"- 20 holes for connecting
rod shoe and closer body mounting screws.
Remove template and use mounting screws to
install the closer body to the top jamb and the
connecting rod shoe to the door. Closer body
should be oriented so that the speed regulating
valves are toward the hinge stile of door.
A longer connecting
rod is required for
reveals greater
than 4" (102mm)
Press pinion cap onto un-used closer body
spindle. If installing cover instead of pinion cap,
slide cover over closer body and secure by
tightening screws.
Orient main arm so that the “H”, located on the main
arm, lines up with the flat on the spindle. Press arm
down on spindle and secure with spindle bolt.
Slide connecting rod into forearm
of main arm. Rotate main arm until
connecting rod is at a 90˚ angle to
frame. While holding arm in this
position, tighten down forearm screw.
Door Opening DimensionA”
To 100 7-1/2"
(191mm)
6"
(152mm)
3-1/2"
(89mm)
101 to 120
121 to *180
*Door/Wall/Hardware/Jamb
conditions permitting
Speed regulating valves toward hinge edge.
5300 Series Door Closer - Top Jamb Arm
Installation Instructions
Meets ANSI A156.4
5
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149
Reveal
FRAME
WHEN ASSEMBLING TO SPINDLE
POSITION OF MAIN ARM
RIGHT HAND DOOR
PINION FLAT
90˚
RIGHT
ANGLE
6. OPTIONAL HOLD-OPEN ARM
Identify direction of hold-open nut according to hand of
door and mount arm.
Adjust by loosening hold-open nut, then open door to
desired position and tighten hold-open nut securely.
7. ADJUSTMENTS
See Adjustments on
Page 6 for setting
Spring Power, Sweep
Speed, Latch Speed,
and Backcheck.
NOTE: Do not fully unscrew valves
or hydraulic fluid will leak and closer
will no longer be functional.
LSLS
++
BC
+
ADJUSTMENTS (USE 5/32" HEX WRENCH FOR THESE ADJUSTMENTS)
SPRING POWER ADJUST (Sizing in accordance to BHMA/ANSI 156.4)
ARM PLACEMENT IN SHOE
SWEEP SPEED LATCH SPEED BACKCHECK OPTIONAL DELAY ACTION
5300 Series Door Closer - Adjustments
Installation Instructions
Meets ANSI A156.4
6
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149
Adjust latch speed so door
completely closes and latches.
Adjust backcheck accordingly
to prevent excessive opening
speed.
Note: Adjust closing time speed
to between 3 and 7 seconds
from 90˚ to 0˚. Greater closing
times may be required for
elderly or handicapped.
7-1/2% Stronger
7-1/2% Weaker
or
or
Interior Door Width
24"
(610mm)
30"
(762mm)
34"
(865mm)
38"
(965mm)
48"
(1219mm)
54"
(1372mm)
Size 2
(5ccw) Size 3
(0) Size 4
(5cw) Size 5
(10cw) Size 6
(15cw)
Size 1
(5ccw)
Size 1
(10ccw)
Size 2
(0) Size 3
(5cw) Size 4
(10cw) Size 5
(15cw)
Exterior (and Vestibule) Door Width
24"
(610mm)
30"
(762mm)
36"
(914mm)
42"
(1067mm)
48"
(1219mm)
Size 3
(0) Size 4
(5cw)
Size 4
(10cw) Size 5
(15cw)
Size 5
(10cw) Size 6
(15cw)
Size 3
(5cw)
Regular Arm &
Top Jamb
Parallel Arm
Regular Arm &
Top Jamb
Parallel Arm
Minimum Door Width (24")
Minimum Door Width (24")
(Use 5/32" Hex Wrench
for this adjustment)
TABLE OF SIZES
Closer is shipped set to size
3. To change the closer size,
use a hex wrench to rotate
the spring power adjust.
Follow the chart to make the
correct numbers of 360°
turns to set the closer size
appropriately for the door
application.
The number of turns is an
approximation and does not
account for environmental or
door hardware affects.
Approx. 5 turns to
increase / decrease one size.
cw = clockwise
ccw = counterclockwise
----
----- 60"
(1524mm)
-
ADJUSTMENT DIAGRAM
DELAY
LS
Adjust delay action accordingly to
obtain desired delay time.
BC