Halsey Taylor Ovl Ii Er Q Users Manual 97793C

OVL-II SR-Q to the manual 952d709d-24b5-49a2-af67-dcc3190066fe

2015-02-09

: Halsey-Taylor Halsey-Taylor-Ovl-Ii-Er-Q-Users-Manual-563370 halsey-taylor-ovl-ii-er-q-users-manual-563370 halsey-taylor pdf

Open the PDF directly: View PDF PDF.
Page Count: 12

DownloadHalsey-Taylor Halsey-Taylor-Ovl-Ii-Er-Q-Users-Manual- 97793C  Halsey-taylor-ovl-ii-er-q-users-manual
Open PDF In BrowserView PDF
OVLERQ*C OVLSRQ*C OVLESRQ*F OVLSERQ*F

HALSEY TAYLOR OWNERS MANUAL
OVLTM Series Barrier-Free Water Coolers
Refrigerated Fountains with Back Panel

Figure 1 – OVL-II ER-Q

Figure 2 – OVL-II SR-Q

Figure 3 – OVLII SER-Q

Figure 4 – OVL-II ESR-Q

Figure

Model

Description

1
2

OVL-II ER-Q
OVL-II SR-Q

OVL-II Series - Extended Reach
OVL-II Series - Standard Reach

3
4

OVL-II SER-Q
OVL-II ESR-Q

OVL-II Series - Dual Installation
OVL-II Series - Dual Installation

INSTALLER

!

CAUTION:

Review these instructions before beginning installation. Be sure that installation
conforms to all plumbing, electrical and other applicable codes.

!

WARNING:

When installation is complete, ensure these instructions are left in the plastic bag
provided inside the installed unit for future reference.

!

WARNING:

Service to be performed by authorized service personnel only.

NOTE:

It is common practice to ground electrical hardware such as telephones, computers and other devices to
available water lines. This can, however, cause electrical feedback in the plumbing circuit, which results in an
“electrolysis” effect occurring in the fountain. This may result in water which has a metallic taste to it or has a
noticeable increase in the metallic content of the water.
When inspecting plumbing circuit, remember the line may be grounded some distance from the installation,
and may occur outside the building or area in which the unit is being installed.
This condition can be avoided (in most cases) by using recommended materials during installation. Any drain
fittings provided by the installer should be made of plastic which will electronically isolate the fountain from the
remainder of the building’s plumbing circuits.

1

97793C - 10/01

OVLERQ*C OVLSRQ*C OVLESRQ*F OVLSERQ*F
1/4" O.D. TUBE
WATER INLET
TO COOLER

3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY

Installation Package
The components for installation are packed in three
separate boxes, regardless of the type of unit being
installed. The boxes contain the following:

BUILDING WATER INLET

NOTE: WATER FLOW
DIRECTION

Box No. 1: Wall Frame(s)
Box No. 2: Remote Chiller, SJ8-Q
Box No. 3: Fountain(s), Arm(s) and Panels

SERVICE STOP
(NOT FURNISHED)

Additional materials, as noted in the Parts List, are also
shipped in these boxes.

Figure 5 – Water Supply Connections

Parts List
Item

Part No.

OVL-II
SR-Q

OVL-II
SER-Q

OVL-II
ESR-Q

See
Fig.

Bottom Cover – Standard Reach

-

1

1

1

23

26988C

Bottom Cover – Extended Reach

1

-

1

1

23

55836C

Push Arm Actuator

1

1

2

2

20

55991C

Push Arm Actuator – A.G.

1

1

2

2

20

51546C

Bubbler – S.S.

1

1

2

2

23

45396C

Bubbler – A.G.

1

1

2

2

23

Bubbler – EasyFlex™ (option)

1

1

2

2

-

100322740560

Bubbler Gasket

1

1

2

2

23

160270508640

Strainer Plate – S.S.

1

1

2

2

23

2

3

5

OVL-II
ER-Q

26990C

1

4

Description

Number Required

Strainer Plate – A.G.

1

1

2

2

23

6

101570540560

Drain Gasket

1

1

2

2

23

7

51575C

Packing Ring

1

1

2

2

23

8

110346220550

Drain Nut

1

1

2

2

23

9

101637451550

Friction Ring

1

1

2

2

23

161637308640

Drain Plug – S.S.

1

1

2

2

23

45398C

Drain Plug – A.G.

1

1

2

2

23

45683C

Drain Tube

1

-

1

1

23

45682C

Drain Tube

-

1

1

1

23

10

45400C

11
12

100023340560

Waste Tube Gasket

1

1

2

2

23

13

161570808550

Slip Nut

1

1

2

2

23

14

61314C

Regulator

1

1

2

2

22

15

50986C

Regulator Holder

1

1

2

2

22

27006C

Basin – S.S.

1

1

2

2

23

27342C

Basin – A.G.

1

1

2

2

23

Basin – Galaxy Gray Marblyte (option)

1

1

2

2

-

Basin – Golden Sand Marblyte (option)

1

1

2

2

-

Basin – Black Onyx Marblyte (option)

1

1

2

2

-

27000C

Basin Liner – S.S.

1

1

2

2

23

27344C

Basin Liner – A.G.

1

1

2

2

23

16

17

97793C - 10/01

Basin Liner – Galaxy Gray Marblyte (option)

1

1

2

2

-

Basin Liner – Golden Sand Marblyte (option)

1

1

2

2

-

Basin Liner – Black Onyx Marblyte (option)

1

1

2

2

-

2

OVLERQ*C OVLSRQ*C OVLESRQ*F OVLSERQ*F
Parts List Continued
OVL-II
ER-Q

OVL-II
SR-Q

OVL-II
SER-Q

OVL-II
ESR-Q

See
Fig.

Screw #10-24 x 2

1

1

2

2

23

Top Plate – Actuator

1

1

2

2

20

Bottom Plate – Actuator

1

1

2

2

20

Extended Reach Arm – S.S.

1

-

1

1

23

Extended Reach Arm – A.G.

1

-

1

1

23

27004C

Standard Reach Arm – S.S.

-

1

1

1

23

27340C

Standard Reach Arm – A.G.

-

1

1

1

23

22

26992C

Regulator Mounting Bracket

1

1

2

2

21

23

15005C

Nut – Retaining

1

1

2

2

22

24

40045C

Hex Nut – Unplated

1

1

2

2

22

25

27008C

Reaction Bracket

1

1

2

2

21

26

70856C

Screw #10-24 x 0.38 PHMS

1

1

2

2

21

27

70854C

Rod – Pivot

1

1

2

2

21

28

50198C

Bushing Snap

1

1

2

2

21

29

51468C

Bumper – Regulator Valve Assy

1

1

2

2

21

30

22646C

Regulator Arm Assembly

1

1

2

2

21

31

22635C

Arm – Regulator Adjustment

1

1

2

2

21

22797C

Upper Panel (OVL-II ER) – S.S.

1

-

-

-

13, 23

27885C

Upper Panel (OVL-II ER) – A.G.

1

-

-

-

13, 23

22799C

Upper Panel (OVL-II SR) – S.S.

-

1

-

-

13, 23

27887C

Upper Panel (OVL-II SR) – A.G.

-

1

-

-

13, 23

26958C

Upper Panel (OVL-II SER) – S.S.

-

-

1

-

13, 23

27889C

Upper Panel (OVL-II SER) – A.G.

-

-

1

-

13, 23

22795C

Upper Panel (OVL-II ESR) – S.S.

-

-

-

1

12, 23

27891C

Upper Panel (OVL-II ESR) – A.G.

-

-

-

1

12, 23

26833C

Lower Panel (OVL-II ER-Q/SR-Q) – S.S.

1

1

-

-

15, 23

27893C

Lower Panel (OVL-II ER-Q/SR-Q) – A.G.

1

1

-

-

15, 23

27026C

Lower Panel (OVL-II SER-Q/ESR-Q) – S.S.

-

-

1

1

15, 23

27895C

Lower Panel (OVL-II SER-Q/ESR-Q) – A.G.

-

-

1

1

15, 23

34

55996C

Strainer

1

1

2

2

17, 18

35

70870C

Union – 3/8”

1

1

-

-

17

36

70745C

Union – 3/8 x 1/4”

1

1

1

1

17, 18

Item

Part No.

18

70861C

19

55840C

20

55839C
27002C
27338C

21

32

33

Description

37

70852C

Tee – 3/8”

-

-

1

1

18

N-S

27089C

Upper Panel Hanger Bracket

1

1

-

-

-

N-S

27090C

Upper Panel Hanger Bracket

-

-

1

1

-

N-S

15008C

Bubbler Nipple Assembly

1

1

2

2

-

N-S

56092C

Tubing – Poly (Cut To Length)

1

1

1

1

-

NOTE:

S.S. means Stainless Steel
A.G. means Aztec Gold
N-S means not shown.

3

97793C - 10/01

OVLERQ*C OVLSRQ*C OVLESRQ*F OVLSERQ*F

Models
OVL-II SER-Q – OVL-II ESR-Q
1.

Cut a rectangular wall opening 37-1/2” (953 mm) W x
37-3/4” H (959 mm) and 4-1/2” (114 mm) above the
floor line (see Figure 7). The dimensions are required
to obtain proper rim and bubbler heights for
compliance with ANSI standard A117.1.

2.

Reinforce the wall opening on all sides to adequately
support the water fountain. This reinforcement must
support up to 150 lbs. static load and provide a
means for securing the frame assembly in place.
NOTE:

Figure 6 – OVL-II SER-Q Rough-In

Building construction must allow for
adequate air flow on both sides and top of
remote chiller unit a minimum of 4” (102
mm) is required.

3.

Install plumbing and electrical rough-ins. A junction
box for a (3) wire, 10 amp branch circuit is provided on
the inside of the chiller. (Standard 120 Volts, 60 Hz,
and single phase.)

4.

Remove frames and related hardware from
packaging. Release the two shelf rods by cutting
cable ties. Attach the two frames together through the
upright supports with (4) 5/16” x 3/4” (19 mm) long
bolts and nuts (not provided). Tighten securely.

MAKE SURE FRAME CONFIGURATION MATCHES
THE COOLER TO BE INSTALLED

REVERSED CONFIGURATION:
HIGHER UNIT ON THE RIGHT

STANDARD CONFIGURATION:
HIGHER UNIT ON THE LEFT
Figure 7 – Rough-In Assembly
Dual-Station Mounting Frames
97793C - 10/01

4

5.

OVLERQ*C OVLSRQ*C OVLESRQ*F OVLSERQ*F

Install the frame assembly squarely in wall opening
with frame upright support edges flush with the
finished wall face. Secure the frame to the wall
through holes with (12) 5/16” bolts or screws (not
provided). Tighten securely.
NOTE:

6.

Be sure that frame is squared in location. Do
not use less than required screw quantity
and size.

Attach the chiller shelf support rods to the right side
of the frame uprights at the second set of holes
counting from the bottom and to the shelf at the (2)
side holes. Line up the other shelf holes with the
frame bottom holes and fasten the assembly to the
wall opening using appropriately sized screws or
bolts and nuts (not provided).

Legend
Item

Description

A
B

3/8” O.D. Tube - Water Outlet Connection
3/8” O.D. Tube - Water Inlet Connection

C
D

1-1/4” O.D. Tube - Waste Tube - Not provided
Electrical Inlet on Chiller

Figure 8 – OVL-II SER-Q/OVL-II ESR-Q Rough-In Dimensions

5

97793C - 10/01

OVLERQ*C OVLSRQ*C OVLESRQ*F OVLSERQ*F

Models
OVL-II ER-Q – OVL-II SR-Q
1.

Cut a rectangular wall opening 18-3/4”
(475 mm) W x 37-3/4” H (959 mm) and 4-1/2” (114 mm)
above the floor line (see Figure 10). The dimensions
are required to obtain proper rim and bubbler heights
for compliance with ANSI standard A117.1.

2.

Reinforce the wall opening on all sides to adequately
support the water fountain. This reinforcement must
support up to 150 lbs. static load and provide a
means for securing the frame assembly in place.
NOTE: Building construction must allow for adequate
air flow on both sides and top of remote
chiller unit. Minimum of 4” (102 mm) is
required.

Figure 9 – OVL-II ER-Q/OVL-II SR-Q Rough-In

97793C - 10/01

3.

Install plumbing and electrical rough-ins. A junction
box for a (3) wire, 10 amp branch circuit is provided on
the inside of the chiller. (Standard 120 Volts, 60 Hz,
and single phase.)

4.

Remove frame and related hardware from
packaging. Release the two shelf rods by cutting
cable ties.

Figure 10 – Rough-In Assembly
Single-Station Mounting Frames

6

OVLERQ*C OVLSRQ*C OVLESRQ*F OVLSERQ*F
5.

Install the frame squarely in wall opening with frame
upright edges flush with the finished wall surface.
Place shelf inside frame and line up the (2) holes on
each. Insert loose ends of rods into holes on sides of
shelf panel. Using appropriately sized screws or bolts

(not provided), fasten the shelf and frame to the
bottom of wall opening. Secure the frame sides and
top to the wall opening using (10) 5/16” bolts or
screws (not provided).
NOTE:

MODEL OVL-ER

Legend
Item
A
B
C
D

Be sure that frame is squared in location. Do
not use less than the required screw quantity
and size.

MODEL OVL-SR

Description
3/8” O.D. Tube - Water Outlet Connection
3/8” O.D. Tube - Water Inlet Connection
1-1/4” O.D. Tube - Waste Tube - Not provided
Electrical Inlet on Chiller

Figure 11 – OVL-II ER-Q/SR-Q Rough-In Dimensions

7

97793C - 10/01

OVLERQ*C OVLSRQ*C OVLESRQ*F OVLSERQ*F

REQUIRED TOOLS AND MATERIALS

5. Install fountain: Remove access cover plate on
underside of fountains and SAVE the screws. Mount
the fountains to the upper panel and frame with
(4) 5/16” x 3/4” (19mm) long bolts and nuts provided.
Tighten securely.

These tables show special tools and/or additional
materials (not provided) which are necessary to complete
installation of these units:
Special Tools
Item

Description

Quantity

NONE
Additional Materials
Item

Description

1

Unplated copper inlet pipe

2

Service Stop

Quantity

OVL-II ER-Q/SR-Q/SER-Q/ESR-Q INSTALLATION
1.
2.

Assemble and place frame in wall as shown on
preceding pages.
Install chiller: Remove front panel of chiller. Remove
and discard cardboard inner pack from between
compressor and side panel. Slide chiller onto the
shelf and position it to the left within the guides on the
shelf.
NOTE:

Building construction must allow for
adequate air flow on both sides, top and
back of chiller. A minimum of 4” (102mm) on
both sides and top is required. See chiller
installation for additional instructions.

Figure 13 – Upper Panel Installation
Note: With OVL-II SER-Q or OVL-II ESR-Q models, the
standard reach fountain must be mounted at the
upper position on panel.

Figure 12 – Chiller Installation
3.

4.

Make water supply connections: Attach an unplated
copper water inlet line and a service stop (not
provided) to the chiller. Inlet port is marked on the
chiller (3/8” O.D. copper tube). Bend the copper tube
(provided) at an appropriate length from the chiller to
opening in frame. Install a 3/8” O.D. tube tee fitting
(provided) on the marked chiller outlet port. Turn on
the water supply and flush the line thoroughly.

Figure 14 – Fountain Installation

Hang the upper panel on the mounting frame
hanger: Align holes in the panel with the holes in the
mounting frame. Be sure that panel is engaged with
hanger at top of frame before releasing it.

97793C - 10/01

8

6.

Remove elbow from end of p-trap and attach it to
drain tube. Re-attach elbow to p-trap and cut waste
tube to required length using plumbing hardware and
trap as a guide.

7.

Make connection between remote chiller outlet tube
and fountain strainer. Insert the water inlet line into
inlet side of strainer by pushing it in until it reaches a
positive stop, approximately 3/4” (19mm). Turn on
water supply and check for leaks.

OVLERQ*C OVLSRQ*C OVLESRQ*F OVLSERQ*F

!

CAUTION: DO NOT SOLDER tubes into the

strainer as damage to o-rings may
result.

8.

These products are designed to operate on 20-105
PSIG supply line pressure. If inlet pressure is above
105 PSIG, a pressure regulator must be installed in
the supply line.

!

CAUTION: Any damage caused by connecting
these products to a supply line with
pressure lower than 20 PSIG or
higher than 105 PSIG IS NOT
covered under warranty.

9.

Figure 16 – Stream Height

TO BUBBLER

Make electrical connections to the chiller. See
chiller instructions.

10. Check stream height from bubbler. Stream height is
factory set at 45-50 PSI. If supply pressure varies
greatly from this, remove items 2, 19, and 20 (push
arm and the bottom and the top actuator plates –
Figure 20) by removing the screws holding assembly
together and adjust the screw on the regulator (Item
26 – Figure 21). Clockwise adjustment will raise
stream height and counterclockwise movement will
lower stream height. For best adjustment, stream
height should be approximately 1-1/2” (38mm) above
the bubbler guard. (See Figure 16).

34
35
CHILLER
OUTLET

36

CHILLER
INLET

11. Mount lower panel. Loosen the two (2) #10-24 x 5/8”
(16mm) screws at frame bottom lip. Slide upper
tongue of lower panel under lower edge of already
installed upper panel. Tighten previously loosened
screws securely.
12. Replace bottom access panel to fountain basin
using screws provided. Tighten securely.

Figure 17 – OVL-II ER-Q/SR-Q Tube Routing

TO BUBBLER
TO BUBBLER

34
37
CHILLER
OUTLET

36

CHILLER
INLET

Figure 18 – OVL-II SER-Q/ESR-Q Tube Routing

Figure 15 – Lower Panel Installation

9

97793C - 10/01

OVLERQ*C OVLSRQ*C OVLESRQ*F OVLSERQ*F

TROUBLESHOOTING & MAINTENANCE

Orifice Assembly: Mineral deposits on orifice can cause
water flow to spurt or not regulate. Mineral deposits may
be removed from the orifice by poking with a small round
file not over 1/8” diameter, or using a small diameter wire.

!

CAUTION: DO NOT file or cut orifice
material.

Stream Regulator: If orifice is clean, regulate flow as in
Step 10 of the installation instructions. If replacement is
necessary, see parts list for correct regulator part number.

!

CAUTION: Cleaning of Aztec Gold Models
requires special care. Outer
surfaces must be cleaned with
mild detergent or a mixture of
vinegar and water only, rinsed and
wiped dry. Abrasive and acidic
cleaners may eventually damage
the Aztec Gold finish.

Figure 20 – Push Arm Mechanism

Actuation of Quick Connect Water Fittings: Cooler is
provided with lead-free connectors which utilize an o-ring
water seal. To remove tubing from the fitting, relieve water
pressure, push in on the gray collar while pulling on the
tubing. (See Figure 19) To insert tubing, push tube
straight into fitting until it reaches a positive stop (approximately 3/4”).
SIMPLY PUSH IN
TUBE TO ATTACH

TUBE IS
SECURED
IN POSITION

28

PUSH IN COLLET
TO RELEASE TUBE

PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE

Figure 19 – Quick Connect Fittings

Figure 21 – Regulator Mounting Mechanism

97793C - 10/01

10

OVLERQ*C OVLSRQ*C OVLESRQ*F OVLSERQ*F

23

15

24

14
REGULATOR MOUNTING BRACKET

Figure 22 – Regulator Assembly

32

16

3, 4
See Fig. 22
21

17

See Fig. 20
18
1

5
10

See Fig. 21

6
7

8

9
8

12
13
11
Figure 23 – Fountain Assembly - Side View

11

97793C - 10/01

OVLERQ*C OVLSRQ*C OVLESRQ*F OVLSERQ*F

2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500
PRINTED IN U.S.A.

97793C - 10/01

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620

12



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 12
Create Date                     : 1910:11:20 40:75:22
Producer                        : Acrobat Distiller 3.02
Subject                         : 97793C
Author                          : BLF
Creator                         : Adobe PageMaker 6.52
Title                           : 97793C
EXIF Metadata provided by EXIF.tools

Navigation menu