Hanchett Entry Systems K200 RFID Cabinet Lock User Manual 3085006 001 Rev A 031215

Hanchett Entry Systems, Inc. RFID Cabinet Lock 3085006 001 Rev A 031215

user manual

Download: Hanchett Entry Systems K200 RFID Cabinet Lock User Manual 3085006 001 Rev A  031215
Mirror Download [FCC.gov]Hanchett Entry Systems K200 RFID Cabinet Lock User Manual 3085006 001 Rev A  031215
Document ID2607277
Application IDxtlLKjInU2Vfv0OKX9Ku5Q==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize151.58kB (1894731 bits)
Date Submitted2015-05-07 00:00:00
Date Available2015-06-27 00:00:00
Creation Date2015-03-12 13:13:08
Producing SoftwareAcrobat Distiller 11.0 (Windows)
Document Lastmod2015-05-04 17:45:13
Document TitleMicrosoft Word - 3085006.001_Rev A__031215
Document CreatorPScript5.dll Version 5.2.2
Document Author: StSteg

K200-622
Cabinet Lock Series
Installation Instructions
HES, Inc.
Phoenix, AZ
1.800.626.7590
www.hesinnovations.com
Package Contents
Mounting
Templates
Lock Reader
Key Override
Paddle
Shaft Extension
1X
1X
6 x 1/2”
1X
Machine
screw with
washer
Strike
Plate
Interface Cable,
System Side
2-56x3/8”
0-80x½”
2X
3X
1X
2-56x1-1/4”
1X
6‐32 screws
5/16”
3X
Lock Body
1”
2X
1-1/4”
2X
Double door bracket
1-5/8”
1X
1-3/4”
2X
1-7/8” 2‐1/2”
2X
2X
Interface Cable, Lock Side
Recommended Tools
Drill, Drill bits: 5/32”, 1/2”
Flathead drivers 3/32”, 3/16”
Optional:
Approved Credential:
Phillips drivers P0, P2
Cam Lock for key override
i.e. iCLASS or Prox ID card
Pencil, Wire Stripper
Specifications
Voltage: 12–24 VDC ±10% (Power Supply not provided)
Power Consumption: <3W peak, 0.5W steady state
Operating Temperature: -10C to 50C
Holding Force: 250 lbs
Part Number 3085006.001, Rev. A
External Interface Signals Summary:
Lock Signal
Name
Vin
Lock Signal
Direction and Wire
Color
Input,
Red/24 AWG
Electrical Interface
Logic
Power to Reader
Input Power
Active High
Unlock
Input,
Orange/24 AWG
Wetted Relay Contact
Closure
(0–35 VDC)
Tamper / Door
Position +
Output,
Yellow/24 AWG
Dry Contact
(0–35 VDC, <100mA)
Open = Unlocked
Tamper / Door
Position –
Output,
Blue/24 AWG
Dry Contact
(0–35 VDC, <100mA)
Open = Unlocked
Closed = Locked
Closed = Locked
Wiegand Data 0
Output,
Green/24 AWG
0–5 VDC
Active Low
Wiegand Data 1
Output,
White/24 AWG
0–5 VDC
Active Low
Green LED
Input,
Brown/24 AWG
0–5 VDC
Active Low
Input,
White/Brown/24 AWG
0–5 VDC
Active Low
Red LED
Ground/Return
Input,
Black/24 AWG
–
–
LED Function: LED states are controlled and defined by the User’s EAC. Enabling the red and green LEDs on
the K200 occurs via an active low (ground) signal.
Output Type: SIAAC-01-1996 Wiegand Output Compliant.
FCC Part 15, Compliant, Industry Canada Compliant
BHMA: A156.3, A156.36, A156.25 Compliant
Credentials Supported: 125kHz Proximity or 13.56MHz iCLASS, iCLASS SEOS, iCLASS SE, ISO 15693
ICLASS, ISO 14443A Mifare, Mifare Plus, Desfire SE, Desfire EV1, and NFC over HCE.
SYSTEM OVERVIEW
The K200-622 wired cabinet lock (K200) extends access control to a cabinet or drawer. The K200 lock is capable
of reading radio-frequency identification (RFID) credentials and providing that credential data to an electronic
access control (EAC) system via Wiegand data signaling. The EAC is responsible for determining whether user
access should be granted or denied. When the EAC provides an active-high unlock signal to the lock in the access
granted case, the K200 drives a motor to complete the unlock/lock cycle. EAC indication of user access/denial is
provided to the user by way of LED control inputs on each lock. Additional lock monitoring features (e.g., door
position, tamper) are monitored within the lock and status of each is provided to the EAC.
Part Number 3085006.001, Rev. A
TESTING THE LOCK
1. TEST the lock with a known good credential to confirm
it will open as desired when installed.
a. REMOVE the cover from the lock body.
b. PASS the wire and shaft from the reader through
the lock body.
NOTE:
The wire connector is keyed.
c. CONNECT the wire connector from the reader to
the socket in the lock compartment.
d. CONNECT the 10-position Molex Micro-Fit 3.0 cable
between the K200 and the EAC, and ENSURE power is
ON.
e. PRESENT a credential known to the EAC.
f.
WHEN a green LED indicates access is granted,
THEN TWIST the knob to retract the latch.
g. Carefully UNPLUG the cable, and SEPARATE the
lock and reader to prepare for installation.
Part Number 3085006.001, Rev. A
MOUNTING THE LOCK
NOTE:
The K200 reader and lock body can be oriented in several ways to accommodate various cabinets and
drawers. When selecting an orientation, it should be noted that some reader orientations may prevent use
of the key override function. For example, in the door handing shown here, the key override paddle cannot
be accessed in orientation “A”, but it can be accessed in orientations “B,” “C” and “D”.
1. ESTABLISH the horizontal centerline of the latch.
a. HOLD the lock body to the inside of the door and POSITION it generally where you would like it to mount.
b. LOCATE lock centerline notch on the latch, and MARK this point on the inside of the cabinet door using a
pencil.
c. DRAW the horizontal latch centerline from this mark on the inside of the cabinet door and TRANSFER it to the
outside of the cabinet door.
d. TRANSFER this centerline to the inside of the cabinet or the second door on a double-door cabinet.
Part Number 3085006.001, Rev. A
2. TRANSFER the location of the inside wall of the cabinet to the door.
a. MEASURE the horizontal distance between the inside edge of the cabinet and the door edge.
NOTE:
The drawn line depicts the location of the strike mounting surface.
b. LOCATE the lock centerline notch on the latch and MARK this point on the inside of the cabinet door using a
pencil.
c. DRAW the horizontal latch centerline from this mark on the inside of the cabinet door and TRANSFER it to the
outside of the cabinet door.
3. PLACE and USE the Lock/Reader Template.
NOTE:
The orientation will be reversed for a right hand door.
a. CUT through line to separate the Strike Plate Template.
b. PEEL OFF the protective layer of the Lock Template, ALIGN it to both the latch centerline and the line depicting
the inside wall of cabinet, and PRESS to secure.
NOTE:
Two of the holes in the following step are 3/16” [4.76 mm] diameter and two are 1/2” [12.70 mm]
diameter. The two pilot holes are 1/16” [1.59 mm].
c. DRILL four holes and two pilot holes through the cabinet, as shown in the figure below.
d. DRILL only one 3/16” [4.76 mm] hole, depending on the desired Antenna/Reader orientation.
e. IF the optional key override will be installed,
THEN GO TO Step 5.
f.
REMOVE the lock template from the door.
Part Number 3085006.001, Rev. A
4. INSTALL the shaft extension.
a. IF the cabinet door thickness is greater than ½” [12.70 mm] (see Table 1),
THEN INSTALL the Shaft Extension to the Antenna/Reader to ensure proper engagement into the lock.
b. INSTALL the Shaft Extension to the shaft as shown in the figure, and firmly TIGHTEN the screw.
Table 1
Door Thickness
Extension Shaft Used?
1/16” [1.59 mm] – ½” [12.70 mm]
No
> ½” [12.70 mm] – 1 ½” [38.10 mm]
Yes
5. IF a Cam Lock key override will be used,
AND the orientation allows for installation,
THEN INSTALL the Key Override Paddle.
a. INSERT the paddle’s arm into the opening shown, and ALIGN the rails of the paddle to the ones on the lock.
b. SLIDE the paddle gently until it stops.
6. PREPARE the Key Override Door.
NOTE:
The Cam Lock is optional and must be obtained by others.
a. IF a Key Override is used,
THEN MARK and DRILL a hole for a 3/4” [19.05 mm] Cam Lock in the door using the template as a guide.
b. INSTALL the optional Cam Lock with the Cabinet Lock as shown in the figure.
Part Number 3085006.001, Rev. A
7. INSTALL the Antenna/Reader.
CAUTION
Pinching the wires may prevent the Reader and Lock from properly functioning.
a. PLACE and HOLD the antenna/reader to the outside of cabinet, routing the wire through the 1/2” [12.70 mm]
offset hole, and ENSURE the knob is in the locked position in the vertical.
NOTE:
Using the table below will help determine the length of the top mount screw needed, based on the
thickness of the cabinet door.
b. INSTALL the top mount screw to attach the antenna/reader to the outside case.
8. INSTALL the lock.
a. REMOVE the cover from lock.
b. PLACE the lock on the inside of the door, threading the cable through the lock.
c. ATTACH the lock to the antenna/reader using two 8-32 [4.00 mm] lock mount screws (see Table 2 for length),
and TIGHTEN the screws.
d. INSTALL the two #6 [3.5 mm] self-threading screws, and TIGHTEN.
NOTE:
The third #6 [3.5 mm] self-threading screw is important to achieve maximum holding force for doors
greater than 5/8” [15.88 mm] thick.
e. INSTALL the third #6 [3.5 mm] self-threading screw only if the door is greater than 5/8” [15.88 mm] thick,
using the lock as a guide, and TIGHTEN.
Part Number 3085006.001, Rev. A
9. CONNECT the antenna/reader wire to the lock body.
NOTE:
The antenna/reader wire connector is engineered to fit only one way.
a. INSERT the antenna/reader wire connector, ensuring correct orientation
b. TUCK excess cable into the lock body.
c. ATTACH the cover.
Part Number 3085006.001, Rev. A
10. CONNECT the 10-position Molex Micro-Fit Cable between the K200 and the EAC.
11. ENSURE the following power cabling guidelines are followed:
Wire AWG
Supply Voltage
Allowed Cable Length (ft.)*
12
872
24
6679
12
548
24
4201
12
345
24
2641
20 AWG
22 AWG
24 AWG
* Round trip loss. V = 2 x I x R x xft
xft = V / (2 x I x R)
12. POSITION the cable out of the way, as required.
13. PREPARE for the single door strike plate.
a. PEEL OFF the protective layer of the Strike Plate Template and ALIGN it to both the latch centerline and the
cabinet edge.
b. DRILL the two pilot holes shown on the template.
c. REMOVE the template.
Part Number 3085006.001, Rev. A
CAUTION
The Installer must ensure that the lock can be opened before closing the cabinet door.
14. INSTALL the single door strike plate.
PLACE the strike plate over the pilot holes, and INSERT and TIGHTEN the two screws in the slotted holes.
CLOSE the door to verify installation, and ADJUST the strike plate if necessary.
INSERT and TIGHTEN the lock down screw on the strike plate.
15. INSTALL for the double-door strike plate mounting bracket. (OPTIONAL)
NOTE:
The double-door strike plate bracket requires that one door can be secured.
a. PLACE the bracket on door, making sure it aligns with the mark made in Step 2c and the edge of the door.
b. MARK the door.
c. REMOVE the bracket and DRILL pilot holes at the two marks.
d. INSTALL the bracket using the provided mounting screws.
16. INSTALL the double-door strike plate.
a. PLACE the strike plate over the holes on the bracket.
b. INSERT and TIGHTEN the three 6-32 x 5/16” (3.5 mm x 7.94 mm) provided screws.
Part Number 3085006.001, Rev. A
10
FCC Statement
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy and if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Operation with non-approved equipment is likely to result in interference to radio and TV reception. The user is
cautioned that changes and modifications made to the equipment without the approval of manufacturer could void the
user’s authority to operate this equipment.
IC Statement
This device complies with Industry Canada license-exempt RSS standards(s). Operation is subject to the following
two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation.
CE Statement
HES hereby declares that these proximity readers are in compliance with the essential requirements and other relevant provisions of
Directive 1999/5/EC.
Conformité aux normes FCC
Cet équipement a été testé et trouvé conforme aux limites pour un dispositif numérique de classe B, conformément à
la Partie 15 des règlements de la FCC. Ces limites sont conçues pour fournir une protection raisonnable contre les
interférences nuisibles dans une installation résidentielle. Cet équipement génère, utilise et peut émettre des
fréquences radio et, s'il n'est pas installé et utilisé conformément ment aux instructions du fabricant, peut causer des
interferences nuisibles aux communications radio. Rien ne garantit cependant que l'interférence ne se produira pas
dans une installation particulière. Si cet équipement provoque des interférences nuisibles à la réception radio ou de
télévision, qui peut être déterminé en comparant et en l'éteignant, l'utilisateur est encouragé à essayer de corriger les
interférence par une ou plusieurs des mesures suivantes:
Réorienter ou déplacer l'antenne de réception.
Augmenter la distance entre l'équipement et le récepteur.
Branchez l'appareil dans une prise sur un circuit différent de celui auquel le récepteur est connecté.
Consultez votre revendeur ou un technicien radio / TV pour assistance.Avertissement
Les changements ou modififications à cet appareil sans expressément approuvée par la partie responsable de
conformité pourraient annuler l'autorité de l'utilisateur de faire fonctionner cet équipement.
Conformité aux normes IC
Cet appareil est confrome avec Industrie Canada exempt de license RSS standard(s). Son fonctionnement est
souimes aux deux conditions suivantes:
(1) cet appareil ne peut causer d’interférences, et
Part Number 3085006.001, Rev. A
11
(2) cet appareil doit accepter toute interference, y compris des interférences qui peuvent provoquer un
fonctionnement indésirable du périphérique.
Conformité aux normes CE
HES déclare par la présente que ces lecteurs à proximité sont conformes aux exigences essentielles et aux autres
stipulations pertinentes de la Directive 1999/5/CE.
For Technical Support please call 1-800-626-7590
Part Number 3085006.001, Rev. A
© 2015, Hanchett Entry Systems, Inc., an ASSA ABLOY Group Company.
12

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2015:05:04 17:45:13-07:00
Create Date                     : 2015:03:12 13:13:08-07:00
Metadata Date                   : 2015:05:04 17:45:13-07:00
Format                          : application/pdf
Title                           : Microsoft Word - 3085006.001_Rev A__031215
Creator                         : StSteg
Producer                        : Acrobat Distiller 11.0 (Windows)
Document ID                     : uuid:29b05b86-58ff-408e-8cb8-afef98f34d73
Instance ID                     : uuid:d9b52027-0b7b-4837-b394-f5fd91589054
Page Count                      : 12
Author                          : StSteg
EXIF Metadata provided by EXIF.tools
FCC ID Filing: VC3-K200

Navigation menu