Hangzhou Hikvision Digital Technology 16PK Keypad User Manual

Hangzhou Hikvision Digital Technology Co., Ltd. Keypad

Contents

User Manual

Keypad User Manual 1                     LCD  Keypad User Manual
Keypad User Manual 2  About this Manual This Manual is applicable to LCD keypad. The Manual includes instructions for using and managing the product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the  Manual  is  subject  to  change,  without  notice,  due  to  firmware  updates  or  other  reasons. Please find the latest version in the company website (http://overseas.hikvision.com/en/).   Please use this user manual under the guidance of professionals. Legal Disclaimer REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF PRODUCT SHALL BE WHOLLY AT YOUR  OWN  RISKS.  OUR  COMPANY  SHALL  NOT  TAKE  ANY  RESPONSIBILITES  FOR  ABNORMAL OPERATION,  PRIVACY  LEAKAGE  OR  OTHER  DAMAGES  RESULTING  FROM  CYBER  ATTACK,  HACKER ATTACK, VIRUS  INSPECTION, OR  OTHER INTERNET SECURITY RISKS; HOWEVER, OUR COMPANY  WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.   SURVEILLANCE  LAWS  VARY  BY  JURISDICTION.  PLEASE  CHECK  ALL  RELEVANT  LAWS  IN  YOUR JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE CONFORMS THE APPLICABLE LAW. OUR COMPANY SHALL NOT BE LIABLE IN THE EVENT THAT THIS PRODUCT IS USED WITH ILLEGITIMATE PURPOSES.   IN  THE  EVENT  OF  ANY  CONFLICTS  BETWEEN  THIS  MANUAL  AND  THE  APPLICABLE  LAW,  THE  LATER PREVAILS.  0100001050519
Keypad User Manual 3  Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. FCC Conditions This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation EU Conformity Statement  This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014/30/EU, the RE Directive 2014/53/EU, the RoHS Directive 2011/65/EU.   2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment,
Keypad User Manual 4  or dispose of it at designated collection points. For more information see: www.recyclethis.info.  2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see: www.recyclethis.info. Industry Canada ICES-003 Compliance This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:   (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.  Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.
Keypad User Manual 5  Safety Instruction These instructions are intended to ensure that the user can use the product correctly to avoid danger or property loss. The precaution measure is divided into ‘Warnings’ and ‘Cautions’: Warnings: Serious injury or death may be caused if any of these warnings are neglected. Cautions: Injury or equipment damage may be caused if any of these cautions are neglected.   Warnings  Follow  these  safeguards  to  prevent serious injury or death. Cautions  Follow  these  precautions  to  prevent potential injury or material damage. Warnings:  Please  adopt  the  power  adapter  which  can  meet  the  safety extra  low  voltage (SELV)  standard. The power consumption cannot be less than the required value.  Do  not  connect  several  devices  to  one  power  adapter  as  an  adapter  overload  may  cause over-heating and can be a fire hazard.  When the product is installed on a wall or ceiling, the device should be firmly fixed.  To  reduce the risk of  fire or  electrical  shock,  do not expose the  indoor used  product to  rain or moisture.  This installation should be made by a qualified service person and should conform to all the local codes.  Please  install  blackouts  equipment  into  the  power  supply  circuit  for  convenient  supply interruption.  If the product does not work properly, please contact your dealer or the nearest service center. Never attempt to disassemble the product yourself. (We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.)  Please  do  not  look  directly  into  the  laser  light  within  6  meters  because  laser  is  hazardous  to humans.
Keypad User Manual 6  Cautions:  Make sure the power supply voltage is correct before using the product.  Do not drop the product or subject it to physical shock. Do not install the product on vibratory surface or places.  Do not expose it to high electromagnetic radiating environment.  Do  not  aim  the lens  at  the  strong  light such as sun  or  incandescent lamp.  The  strong light  can cause fatal damage to the product.  The  sensor  may  be  burned  out  by  a  laser  beam,  so  when  any  laser  equipment  is  being  used, make sure that the surface of the sensor not be exposed to the laser beam.  For working temperature, please refer to the specification manual for details.  To avoid heat accumulation, good ventilation is required for a proper operating environment.  While shipping, the product should be packed in its original packing.  Please use the provided glove when open up the product cover. Do not touch the product cover with fingers directly, because the acidic sweat of the fingers may erode the surface coating of the product cover.  Please use a soft and dry cloth when clean inside and outside surfaces of the product cover. Do not use alkaline detergents.  Improper use or replacement of the battery may result in hazard of explosion. Please use the manufacturer recommended battery type.
7  Content   Chapter 1 Introduction _____________________________________ 8 1.1 Overview  _______________________________________________ 8 1.2 Appearance Description ____________________________________ 8 1.3 Keypad Beeper and Indicator_______________________________ 10 Chapter 2 Installation and Wiring ___________________________ 13 2.1 Wiring Connector Description ______________________________ 13 2.2 Keypad Address Settings __________________________________ 13 2.3 Keypad Installation _______________________________________ 14 2.4 Keypad Wiring  __________________________________________ 15 Chapter 3 Keypad Operation (Local Operation) _______________ 15 3.1 Keypad Alarm Operation Code  _____________________________ 15
Keypad User Manual 8  Chapter 1 Introduction   1.1 Overview      DS-PK00/PK00M/-LCD/LED series LCD/LED alarm keypad are used for connecting to  the  security  control  panel.  It  implements  operations  on  the  security  control panel  through  programming  and  prompts  alarm  with  the  indicators  and  audio alert. 1.2 Appearance Description
Keypad User Manual 9   No. Description 1 LCD Screen 2 Keypad 3 Control Panel 4 Indicator Bar  Control Panel  Button Description  Panic Button  Programming Button  Search Button  Bypass Button  Exit Button  Stay Arming Button  Away Arming Button Indicator Bar  Button Description  Status Indicator  Operating Indicator  Power Indicator  Arming Indicator  Stay Arming Indicator
Keypad User Manual 10  1.3 Keypad Beeper and Indicator Beeper Description No. Sound Prompt Description 1 One Beep Pressing  keys  prompt;  The  command  is  timed out or the command is too long. 2 Two Beeps Valid  command.  Uploading  the  report completed. 3 Five Beeps Invalid  command.  Failed  to  upload  the  report in 60s. 4 Continuous Beeping For Two Seconds Fault Prompt 5 Slowly Continuous Beeps Entry/Exit Delay 6 Rapidly Continuous Beeps Entry/Exit Delay, less than 10s. 7 Rapid Beeps Zone Alarm; The keyboard is not registered. 8 Three Long Beeps and Two Short Beeps The  tampering  prevention  of  the  keyboard  is turned on. 9 Three Beeps Registering the keyboard completed. 10 One Beep In Two Seconds Two  minutes  before  auto  arming/disarming; One  minute  before  arming  for  temporary password. 11 Three Beeps In One Second One minute before auto arming/disarming; 15s before arming for temporary password.
Keypad User Manual 11  Indicator Description Status Working Status Indicator Working Status Indicator Normal Solid Green System Fault Solid Red Power Working Status Indicator Power On Solid Green Stay   Working Status Indicator Working Status Indicator Partition Perimeter Disarmed OFF Partition System Perimeter Armed Orange Arm Working Status Indicator Working Status Indicator Partition Armed Solid Red Partition System Disarmed Solid Green Password Modifying Flicking Green Fob Code Matching Flicking Green Testing Mode Solid Red Programming Flicking Green OPERATING Working Status Indicator Working Status Indicator Normal Solid Green Programming Flicking Green Password Modifying Flicking Green Fob Code Matching Flicking Green Engineering Mode Solid Red System Fault Flicking Orange
Keypad User Manual 12  LED Zone Indicator Zone Working Status Indicator Working Status Indicator Normal OFF Fault Solid Red Alarm Flicking Red Bypass Solid Green Zone Indicator under Engineering Mode (The corresponding zone indicator light will turn orange when operating): No. Description No. Description 1 Off Hook 5 Sending CID Report 2 Dialing 6 Receiving Confirmation 3 Alarm Receiver Off Hook 7 Control Panel On Hook 4 Receiving Handshake 8 Alarm Receiver On Hook Zone Indicator under Status Mode (The corresponding indicator light will be solid red if there is any fault): No. Description No. Description 1 AC Current Interrupted 5 RS-485 Device Disconnected 2 Low Voltage of Storage Battery 6 Wired Network Exception 3 Movement Prevention of Control Panel Turning On 7 Wireless Network Exception 4 Telephone Line Disconnected 8 Reserved
Keypad User Manual 13  Chapter 2 Installation and Wiring   2.1 Wiring Connector Description  No. Description 1 Loud Speaker 2 Tamper-Proof Switch 3 Wiring Connector 4 DlP Switch 2.2 Keypad Address Settings An  address  is  required  for  each  alarm  keypad  in  the  system.  These  addresses cannot be repeated. Once exchanging the alarm keypad, the address of the new keypad must be the same as the replaced one. You should configure the address via DIP switch of the keypad before powering on the system. The address should be in the range of 1~31.   When it is black on the end of ON as , indicated 1; when it is black on the other end as , indicated 0.
Keypad User Manual 14  1 2 3 4 50001 ■02 ■03 ■ ■04 ■05 ■ ■06 ■ ■07 ■ ■ ■1 2 3 4 508 ■09 ■ ■10 ■ ■11 ■ ■ ■12 ■ ■13 ■ ■ ■14 ■ ■ ■15 ■ ■ ■ ■1234516 ■17 ■ ■18 ■ ■19 ■ ■ ■20 ■ ■21 ■ ■ ■22 ■ ■ ■23 ■ ■ ■ ■1234524 ■ ■25 ■ ■ ■26 ■ ■ ■27 ■ ■ ■ ■28 ■ ■ ■29 ■ ■ ■ ■30 ■ ■ ■ ■31 ■ ■ ■ ■ ■Keyboard Address ON                 DIPKeyboard AddressKeyboard AddressKeyboard AddressON                 DIPON                 DIPON                 DIP 2.3 Keypad Installation Before You Start:  Make  sure  that  the  device  in  the  package  is  in  good  condition  and  all  the assembly parts are included.  Make sure that the wall is strong enough to withstand three times the weight of the keypad.    Set the keypad address before installation. Steps: 1. Route  the  cables  through  the  cable hole of the mounting plate.  2. Secure  the  mounting  plate  on  the wall with 4 supplied screws.
Keypad User Manual 15  3. Connect the corresponding cables. 4. Push  the  keypad  body  in  the mounting plate from bottom up.   5. Fasten  the  keypad  body  with  the three buckles on the plate.  6. Align  the  screw  holes  with  the screws  on  the  bottom  of  both keypad and mounting plate. 7. Tighten the screws to fix the keypad on the mounting plate and complete the installation.  2.4 Keypad Wiring The keypad wiring is shown as follows.       Chapter 3 Keypad Operation (Local Operation) 3.1 Keypad Alarm Operation Code
Keypad User Manual 16  Function Description Command Arming/Disarming Normal(Away)Arming/Disarming 【Password】【 #】 Instant Arming 【Password】【 *】【 7】【 #】 Stay Arming 【Password】【 *】【 4】【 #】   Normal (Away)Arming/Disarming 【Password】【 Bypass】【 #】 Mandatory   【Password】【 *】【 7】【 Bypass】【 #】 Mandatory Instant Arming 【Password】【 *】【 4】【 Bypass】【 #】 Bypass Bypass Zone(n) 【Password】【 Bypass】【 n】【 n】【 n】【 #】    【Bypass】【 n】【 n】【 n】【 #】 nnn is the zone No.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   Group Bypass 【Password】【 *】【 4】【 1】【 #】 Group Bypass   【Password】【 *】【 4】【 2】【 #】 Programming/ Editing Password Control Panel Programming 【Installer Password】【 *】【 0】【 #】 Exit Operation 【*】【 #】 Operator Password 【Operator Password】【 *】【 0】【 #】 【User No. (3digits)】【 #】 【New Password】【 #】 【New Password】【 #】 Clearing Alarm Clearing Under arming status   Clearing under disarming status 【*】【 1】【 #】 【Password】 【*】【 1】【 #】 Keypad Settings Enabling/Disabling Keypad Tone 【*】【 5】【 1】【 #】   Enabling/Disabling Fault Prompt 【*】【 5】【 6】【 #】 LCD Backlight Control     【*】【 5】【 2】【 n】【 n】【 n】【 #】 LCD Backlight Disabling   【*】【 8】【 #】 Testing Testing 【Password】【 *】【 6】【 0】【 #】 Alarm Center Testing   【Password】【 *】【 6】【 1】【 #】 Project Mode   【Password】【 Project】【 9】【 0】【 n】【 #】 Exiting Project Mode   【Project】  or  【*】【 #】 Display/Output   Enabling Alarm Output   【Password】【 *】【 8】【 5】【 n】【 n】【 #】 Disabling Alarm Output   【Password】【 *】【 8】【 6】【 n】【 n】【 #】 System Settings Control Panel Soft Resetting   【Operator Password】【 *】【 6】【 8】【 #】 Initialization   【Installer Password】【 *】【 8】【 9】【 #】 Panic Alarm Panic Alarm 【Panic】
Keypad User Manual 17  Device Status Query   System Fault Status   【Status】 Wireless  User Settings   Pairing  Wireless  Device  and Control Panel   【Password】【 *】【 91】【 No.】【 #】 Deleting the Specified Connected Wireless Device 【Password】【 *】【 90】【 No.】【 #】 Deleting  all  the  Connected Wireless Device 【Password】【 *】【 92】【 #】 Card User Settings   Pairing  Card  No.  and  Control Panel   【Operator】 【Project】【 10】【User No.】 【#】 Deleting the Specified Card   【Operator】【 Project】【 11】【 Card No.】【 #】 【Operator】【 Project】【 12】【 #】 Deleting All Card Of a Specified User   【Operator】【 Project】【 15】【 #】 Exiting Card Pairing Mode   【*】【 #】 Schedule Resetting Current Schedule   【Installer Password】【 *】【 8】【 1】【 #】 Clearing Weekly Schedule   【Installer Password】【 *】【 8】【 2】【 #】 Clearing Prioritized Schedule   【Installer Password】【 *】【 8】【 3】【 #】 Single Zone Operation Arming/Disarming   【Password】【 Project】【 n】【 n】【 n】【 #】 Clearing Alarm 【Password】【 Project】【 n】【 n】【 n】【 #】 Language Settings   Displaying English   【*】【 9】【1】【 1】【 #】 Displaying Chinese   【*】【 9】【 1】【 0】【 #】

Navigation menu