Hangzhou Hikvision Digital Technology K3B601LM Swing Barrier User Manual
Hangzhou Hikvision Digital Technology Co., Ltd. Swing Barrier
User Manual
Swing Barrier User Manual Swing Barrier·User Manual User Manual © 2018 Hangzhou Hikvision Digital Technology Co., Ltd. This manual applies to swing barrier. Product Name Model Description DS-K3B601-L Series Left Pedestal DS-K3B601-M Series Middle Pedestal DS-K3B601-R Series Right Pedestal Swing Barrier DS-K3B601A-L Series Left Pedestal DS-K3B601A-M Series Middle Pedestal DS-K3B601A-R Series Right Pedestal Note: L represents left pedestal, M represents middle pedestal, and R represents right pedestal. It includes instructions on how to use the Product. The software embodied in the Product is governed by the user license agreement covering that Product. About this Manual This Manual is subject to domestic and international copyright protection. Hangzhou Hikvision Digital Technology Co., Ltd. (“Hikvision”) reserves all rights to this manual. This manual cannot be reproduced, changed, translated, or distributed, partially or wholly, by any means, without the prior written permission of Hikvision. Trademarks and other Hikvision marks are the property of Hikvision and are registered trademarks or the subject of applications for the same by Hikvision and/or its affiliates. Other trademarks mentioned in this manual are the properties of their respective owners. No right of license is given to use such trademarks without express permission. Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, REGARDING THIS MANUAL. HIKVISION DOES NOT WARRANT, GUARANTEE, OR MAKE ANY REPRESENTATIONS REGARDING THE USE OF THE MANUAL, OR THE CORRECTNESS, ACCURACY, OR RELIABILITY OF INFORMATION CONTAINED HEREIN. YOUR USE OF THIS MANUAL AND ANY RELIANCE ON THIS MANUAL SHALL BE WHOLLY AT YOUR OWN RISK AND RESPONSIBILITY. REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS. OUR COMPANY SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, OUR COMPANY WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE CONFORMS THE APPLICABLE LAW. OUR COMPANY SHALL NOT BE LIABLE IN THE EVENT THAT THIS PRODUCT IS USED WITH ILLEGITIMATE PURPOSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS. Support Should you have any questions, please do not hesitate to contact your local dealer. Swing Barrier·User Manual Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. FCC Conditions This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. EU Conformity Statement This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the RE Directive 2014/53/EU, the EMC Directive 2014/30/EU, the RoHS Directive 2011/65/EU. 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info ii Swing Barrier·User Manual 2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see: www.recyclethis.info Industry Canada ICES-003 Compliance This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. Cet équipement doit être installé et utilisé à une distance minimale de 20 cm entre le radiateur et votre corps. Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Warnings and Cautions: Warnings: Neglecting any of the warnings may cause serious injury or death. Cautions: Neglecting any of the cautions may cause injury or equipment damage. iii Swing Barrier·User Manual Warnings Follow these safeguards to prevent serious injury or death. Cautions Follow these precautions to prevent potential injury or material damage. Warnings All the electronic operation should be strictly compliance with the electrical safety regulations, fire prevention regulations and other related regulations in your local region. Please use the power adapter, which is provided by normal company. The power consumption cannot be less than the required value. Do not connect several devices to one power adapter as adapter overload may cause over-heat or fire hazard. Please make sure that the power has been disconnected before you wire, install or dismantle the device. When the product is installed on wall or ceiling, the device shall be firmly fixed. If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then please contact the service center. If the product does not work properly, please contact your dealer or the nearest service center. Never attempt to disassemble the device yourself. (We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.) Cautions Stainless steel may be corroded in some circumstances. You need to clean and care the device by using the stainless steel cleaner. It is suggested to clean the device every month. Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage). Do not place the device in extremely hot (refer to the specification of the device for the detailed operating temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation. The device cover for indoor use shall be kept from rain and moisture. Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is forbidden (ignorance can cause fire danger). Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfunction however), and affecting the endurance of sensor at the same time. Please use the provided glove when open up the device cover, avoid direct contact with the device cover, because the acidic sweat of the fingers may erode the surface coating of the device cover. iv Swing Barrier·User Manual Please use a soft and dry cloth when clean inside and outside surfaces of the device cover, do not use alkaline detergents. Please keep all wrappers after unpack them for future use. In case of any failure occurred, you need to return the device to the factory with the original wrapper. Transportation without the original wrapper may result in damage on the device and lead to additional costs. Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or equivalent type only. Dispose of used batteries according to the instructions provided by the battery manufacturer. Swing Barrier·User Manual Table of Contents Chapter 1 Overview ..................................................................................................................... 1 1.1 Introduction..................................................................................................................... 1 1.2 Main Features .................................................................................................................. 1 Chapter 2 Installation .................................................................................................................. 2 2.1 Disassembling Pedestals .................................................................................................. 2 2.2 Installing Pedestals........................................................................................................... 2 Chapter 3 Wiring ......................................................................................................................... 4 3.1 Components Introduction ................................................................................................ 4 3.2 Wiring Electric Supply ...................................................................................................... 4 3.3 Wiring Interconnecting Cable .......................................................................................... 5 3.4 Terminal Description ........................................................................................................ 7 3.4.1 Master Control Board Terminal Description.................................................................. 7 3.4.2 Slave Control Board Terminal Description..................................................................... 7 3.4.3 Main Control Board Terminal Description..................................................................... 8 3.4.4 Main Control Board Serial Port ID Description ............................................................ 11 3.4.5 RS-485 Wiring ............................................................................................................ 12 3.4.6 RS-232 Wiring ............................................................................................................ 13 3.4.7 Wiegand Wiring ......................................................................................................... 14 3.4.8 Barrier Control Wiring................................................................................................ 14 3.4.9 Alarm Output Wiring ................................................................................................. 16 3.5 Wiring Lithium Battery (Optional) .................................................................................. 16 Chapter 4 Device Settings .......................................................................................................... 18 4.1 Setting Closed Position .................................................................................................. 18 4.2 Pairing Remote Control (Optional) ................................................................................. 19 4.3 Initializing Device ........................................................................................................... 19 4.4 Switching RS-485/RS-232 Mode ..................................................................................... 19 4.5 Switching Relay Output Mode (NO/NC) ......................................................................... 20 4.5.1 Barrier Control Relay Output Mode ............................................................................ 20 4.5.2 Alarm Relay Output Mode (NO/NC) ........................................................................... 20 Chapter 5 Device Activation ...................................................................................................... 22 5.1 Activating via SADP Software ......................................................................................... 22 5.2 Activating via Client Software ........................................................................................ 23 Chapter 6 Client Operation ........................................................................................................ 26 6.1 Function Module ........................................................................................................... 26 vi Swing Barrier·User Manual 6.2 User Registration and Login ........................................................................................... 26 6.3 System Configuration ..................................................................................................... 27 6.4 Access Control Management ......................................................................................... 28 6.4.1 Adding Access Control Device .................................................................................... 29 6.4.2 Viewing Device Status ................................................................................................ 42 6.4.3 Editing Basic Information ........................................................................................... 43 6.4.4 RS-485 Settings .......................................................................................................... 43 6.4.5 Authenticating M1 Card Encryption ........................................................................... 44 6.4.6 Remote Configuration ................................................................................................ 45 6.5 Organization Management ............................................................................................ 55 6.5.1 Adding Organization ................................................................................................... 56 6.5.2 Modifying and Deleting Organization ......................................................................... 56 6.6 Person Management...................................................................................................... 56 6.6.1 Adding Person ............................................................................................................ 56 6.6.2 Managing Person ....................................................................................................... 67 6.6.3 Issuing Card in Batch .................................................................................................. 68 6.7 Permission Configuration ............................................................................................... 69 6.7.1 Adding Permission ..................................................................................................... 70 6.7.2 Applying Permission ................................................................................................... 71 6.8 Advanced Functions ....................................................................................................... 72 6.8.1 Access Control Parameters ......................................................................................... 72 6.8.2 Card Reader Authentication ....................................................................................... 75 6.8.3 Multiple Authentication ............................................................................................. 76 6.8.4 Open Door with First Card.......................................................................................... 79 6.8.5 Anti-Passing Back ....................................................................................................... 80 6.9 Searching Access Control Event ...................................................................................... 81 6.9.1 Searching Local Access Control Event ......................................................................... 82 6.9.2 Searching Remote Access Control Event ..................................................................... 82 6.10 Access Control Event Configuration ................................................................................ 83 6.10.1 Access Control Event Linkage ................................................................................. 83 6.10.2 Access Control Alarm Input Linkage........................................................................ 84 6.10.3 Event Card Linkage ................................................................................................. 85 6.10.4 Cross-Device Linkage .............................................................................................. 88 6.11 Door Status Management .............................................................................................. 89 6.11.1 Access Control Group Management ....................................................................... 89 6.11.2 Anti-control the Access Control Point (Door) .......................................................... 91 vii Swing Barrier·User Manual 6.11.3 Status Duration Configuration ................................................................................ 92 6.11.4 Real-time Card Swiping Record............................................................................... 94 6.11.5 Real-time Access Control Alarm.............................................................................. 94 6.12 Arming Control .............................................................................................................. 95 6.13 Time and Attendance .................................................................................................... 96 6.13.1 Shift Schedule Management .................................................................................. 97 6.13.2 Attendance Handling............................................................................................ 103 Appendix A Tips for Scanning Fingerprint .............................................................................. 106 Appendix B DIP Switch Description ........................................................................................ 107 DIP Switch Introduction ........................................................................................................... 107 DIP Switch Corresponded Functions ........................................................................................ 107 Appendix C Table of Audio Index Related Content ................................................................. 109 Appendix D Error Code Description ........................................................................................ 110 viii Swing Barrier·User Manual Chapter 1 Overview 1.1 Introduction The swing barrier with two barriers and 12 IR lights is designed to detect unauthorized entrance or exit. By adopting the swing barrier integratedly with the access control system, person should authenticate to pass through the lane via swiping IC or ID card, scanning QR code, etc. It is widely used in attractions, stadiums, construction sites, residences, etc. 1.2 Main Features 32-bit high-speed processor TCP/IP network communication The communication data is specially encrypted to relieve the concern of privacy leak Permissions validation and anti-tailgating Remaining open/closed mode selectable Bidirectional (Entering/Exiting) lane The barrier opening and closing speed can be configured according to the visitors flow The barrier will be locked or stop working when people are nipped. Anti-forced-accessing The barrier will be locked automatically without open-barrier signal. It can bear the force of up to 120 Nm. Self-detection, Self-diagnostics, and automatic alarm Audible and visual alarm will be triggered when detecting intrusion, tailgating, reverse passing, and climbing over barrier. Remote control and management Online/offline operation LED indicates the entrance/exit and passing status. Barrier is in free status when powered down; If the device is installed with lithium battery (optional), the barrier remains open when powered down Fire alarm passing When the fire alarm is triggered, the barrier will be open automatically for emergency evacuation. Valid passing duration settings System will cancel the passing permission if a person does not pass through the lane within the valid passing duration Opens/Closes barrier according to the schedule template. Up to 3000 visitor cards and up to 60,000 cards except for visitor cards can be added Swing Barrier·User Manual Chapter 2 Installation 2.1 Disassembling Pedestals Purpose: Before installation, you should use the key to open the pedestals. View the pictures below to find the locks and installation holes. 2.2 Installing Pedestals Before you start: Prepare for the installation tools, check the device and the accessories, and clear the installation base. Notes: The device should be installed on the concrete surface or other non-flammable surfaces. If the installation area is too close to the wall, make sure the distance between the pedestal and the wall should be no more than 120 mm, or you cannot open the pedestal’s top panel. Steps: 1. Draw a central line on the installation surface for installing the center pedestal. 2. Draw another two parallel lines on each side of the central line for installing the other two pedestals. Note: The distance between the nearest two line is L+200 mm. L represents the lane width. 3. Drill holes on the ground according to the installation holes on the pedestals and insert the expansion sleeves. 4. Bury interconnecting cables for pedestal communication. Swing Barrier·User Manual Note: For detailed information about burying and wiring interconnecting cables, see 3.3 Wiring Interconnecting Cable. 5. According to the entrance and exit marks on the pedestals, move the pedestals to the corresponded positions. Note: Make sure the installation holes on the pedestals and the base are aligned with each other. 6. Secure the pedestals with expansion bolts. Note: Do not immerse the pedestal in the water. In special circumstances, the immersed height should be no more than 10 mm. The installation footprint is as follows: Swing Barrier·User Manual Chapter 3 Wiring 3.1 Components Introduction Purpose: By default, basic components of the swing barrier are connected well. You should wire the pedestals together for communication and wire the swing barrier to the AC electric supply. Note: The voltage fluctuation of the electric supply is between 100 VAC and 220 VAC, 50 to 60 Hz. The picture displayed below describes each component’s position on the swing barrier. 3.2 Wiring Electric Supply Wire electric supply with the switch in the pedestal. Terminal L and terminal N are on the switch, while terminal PE should connect to a ground wire (yellow and green wire). Swing Barrier·User Manual 3.3 Wiring Interconnecting Cable Purpose: You should use interconnecting cables to connect the master lane board and the slave lane board for components communication. The picture displayed below describes the interconnecting cable hole’s position on the pedestals. Swing Barrier·User Manual The picture displayed below describes the interconnecting cable’s wiring diagram. Notes: The supplied interconnecting cable length is 3.75 m. If you need a longer one, ask our technique supports or sales and purchase 5.5 m interconnecting cables. The inner diameters of the low voltage conduit and the high voltage conduit should be larger than 30 mm. If there is a high-power peripheral (for authentication) installed on the left pedestal (according to the picture displayed above), you should increase the inner diameter of the high voltage conduit. General burying method: Bury one network cable and one AC power cord for the right pedestal and bury one network cable and one AC power cord for the central pedestal before installation. If no AC power cord buried independently, you should bury an AC power cord between the right pedestal and the central pedestal. If you want to bury both of the AC power cord and the low voltage cable at the entrance side, the two cables should be in separated conduits to avoid interference. If all wires of the interconnecting cable have connected with peripherals and more peripherals are required to connect, you should increase the conduit diameter or bury another conduit for the external cable. Swing Barrier·User Manual 3.4 Terminal Description Purpose: The lane controller contains master lane controller and slave lane controller, which controls the IR beams, motor, and other components work. 3.4.1 Master Control Board Terminal Description Purpose: The master lane control board contains lane communication interfaces, interconnecting interface, motor encoder interface, remaining open and fire alarm interface, barrier opening directions interface, people counting interface, remote control receiving antenna, motor drive interface, brake interface, power interface, battery interface, DIP switch, and seven-segment display (SSD). Note: For detailed information about the DIP switch, see Appendix BDIP Switch Description. The picture displayed below is the master control board diagram. 3.4.2 Slave Control Board Terminal Description Purpose: The slave lane control board contains lane communication interfaces, interconnecting interface, motor encoder interface, remaining open and fire alarm interface, barrier opening directions interface, people counting interface, motor drive interface, brake interface, power interface, battery interface, and seven-segment display. The picture displayed below is the slave control board diagram. Swing Barrier·User Manual 3.4.3 Main Control Board Terminal Description Swing Barrier·User Manual Table 3-1 Main Control Board Terminal Description Main Controlling Board Terminal Description +12V Grounding Power Output1 GND Power Output Indicator of Card Reader Control Output (Invalid OK Card Output) Indicator of Card Reader Control Output (Valid ERR Wiegand Card Output) Card BZ Card Reader Buzzer Control Output Reader1 W1 Wiegand Head Read Data Input Data1 W0 Wiegand Head Read Data Input Data0 GND Grounding Indicator of Card Reader Control Output (Invalid OK Card Output) Indicator of Card Reader Control Output (Valid ERR Wiegand Card Output) Card Reader BZ Card Reader Buzzer Control Output W1 Wiegand Head Read Data Input Data1 W0 Wiegand Head Read Data Input Data0 GND Grounding GND Grounding RS-485 BConnect to Card Reader RS485RS-485 B+ Connect to Card Reader RS485+ RS-485 Interface GND Grounding RS-485 CConnect to Card Reader RS485RS-485 C+ Connect to Card Reader RS485+ 5V 5 VDC Power Output Power Output2 GND 5 VDC Grounding GND Grounding RS-232 GConnect to Card Reader RS232RS-232 G+ Connect to Card Reader RS232+ RS-232 Interface GND Grounding RS-232 HConnect to Card Reader RS232RS-232 H+ Connect to Card Reader RS232+ +12V 12 VDC Power Input Power Input GND 12 VDC Grounding C1 Event Alarm Input 4 GND Grounding Event Input C2 Event Alarm Input 3 C3 Event Alarm Input 2 Swing Barrier·User Manual Main Controlling Board Terminal Description GND Grounding C4 Event Alarm Input 1 Exit Button Door Lock (Relay) Alarm Output Network Interface B2 Door 2 Signal Input GND Grounding B1 Door 1 Signal Input D1D1+ D2D2+ NO/NC1 COM1 NO/NC2 COM2 NO/NC3 COM3 NO/NC4 COM4 Door 1 Relay Output(Dry Contact) Door 2 Relay Output(Dry Contact) Alarm Output Relay 1(Dry Contact) Alarm Output Relay 2(Dry Contact) Alarm Output Relay 3(Dry Contact) Alarm Output Relay 4(Dry Contact) LAN Network Accessing Notes: The alarm input hardware interface is normally open by default. So only the normally open signal is allowed. It can be linked to the buzzer of the card reader and access controller, and the alarm relay output and open door relay output. The DIP of RS485 card ID is set as 1 and 4 by default. 1 is for entering, and 4 is for exiting. Set the DIP as 3 for connecting visitor card reader. The Wiegand card reader 1 and 2 respectively refer to the entering and exiting card reader. The alarm output supports network camera accessing. For any requirements, the door lock can control the door barrier status of the third party. D1 controls the barrier opening for entrance, while D2 controls the door opening for exit. For details, see 4.5.1 Barrier Control Relay Output Mode. C3 and C4 in the event input can also be people counting interface. C3 controls people counting for entrance, while C4 controls people counting for exit. When the main control board detects signals in C3 and C4, the people number will be accumulated. For detailed information about people counting and people number, see Configuring People Counting Parameters in 6.4.6 Remote Configuration. 10 Swing Barrier·User Manual 3.4.4 Main Control Board Serial Port ID Description Purpose: You can use the jumper cap on the main control board to switch the interface communication mode. For details about switching between RS-232 and RS-485 communication type, see 4.4 Switching RS-485/RS-232 Mode. According to the picture above, the RS-485 serial port corresponds to UART2 and UART3. RS-232 serial port is corresponded to UART7 and UART8. Wiring Interface is corresponded to UART1, UART4, UART6, UART6, and Lane. The main control board descriptions are as follows: UART2/UART3 Jumper Cap: Reserved serial port. Use the jumper cap to switch the serial port communication mode. You can switch between the RS-485 communication mode and the RS-232 communication mode. By default, it is in RS-485 communication mode. UART6 Jumper Cap: Use the jumper cap to switch the serial port communication mode with the slave lane controller. You can switch between the RS-232 communication mode and the RS-485 communication mode. By default, it is in RS-232 communication mode. UART5 Jumper Cap: Use the jumper cap to switch the serial port communication mode with the slave lane controller. You can switch between the RS-484 communication mode and the RS-232 communication mode. By default, it is in RS-485 communication mode. 11 Swing Barrier·User Manual UART1 Jumper Cap: Use the jumper cap to switch the serial port communication mode with the master lane controller. You can switch between the RS-484 communication mode and the RS-232 communication mode. By default, it is in RS-485 communication mode. Lane: Use the jumper cap to switch the serial port communication mode with the lane controller. By default, the interface is wired and it is in RS-485 communication mode. If wiring other controllers (compatible with Hikvision communication protocol), use the jumper cap to switch between RS-485 and RS-232 communication mode. UART4: The serial port is in the wiring interface according to the picture above, which has a fixed RS-232 communication mode to communicate with the master lane controller. It contains no jumper cap and cannot change the communication mode. UART7/UART8: Reserved serial port. The serial port has a fixed RS-232 communication mode. It contains no jumper cap and cannot change the communication mode. It can connect QR code scanner, card recycler, and text screen. 3.4.5 RS-485 Wiring Notes: There are five RS-485 interfaces, which are for connecting ID card reader, IC card reader, QR code scanner, fingerprint and card reader, card recycler, text screen, fingerprint reader, and face recognition terminal. Take the wiring of RS-485 card reader as an example. For details about text screen, see Configuring Screen Parameters in 6.4.6 Remote Configuration. 12 Swing Barrier·User Manual 3.4.6 RS-232 Wiring Note: There are three RS-232 interfaces (UART4, UART7, and UART8). UART7 and UART8 can connect QR code scanner, card recycler, and text screen, while UART4 can connect QR code scanner, card recycler, text screen, and face recognition terminal. For details about text screen, see Configuring Screen Parameters in 6.4.6 Remote Configuration. Take the wiring of face recognition terminal as an example. 13 Swing Barrier·User Manual 3.4.7 Wiegand Wiring Note: You must connect the OK/ERR/BZ if using access controller to control the LED and buzzer of the Wiegand card reader. 3.4.8 Barrier Control Wiring Purpose: By default, the barrier has connected with the main control board. The lane control board can control the barrier status. If possible, the device can connect with a third party lane control board to control the third party barriers. Interface D1 controls barrier opening for entrance, while interface D2 controls barrier opening for exit. 14 Swing Barrier·User Manual Entering Wiring Exiting Wiring 15 Swing Barrier·User Manual 3.4.9 Alarm Output Wiring Note: For details about changing the relay output status via the jumper cap, see 4.5.2 Alarm Relay Output Mode (NO/NC). 3.5 Wiring Lithium Battery (Optional) Purpose: The lithium battery supplies power for master lane control board and slave lane control board when the device is powered off. The battery interface position is as follows: Before you start: Ask our technique support and sales and purchase for the lithium battery. Steps: 1. Install lithium batteries. 1) Remove the screws on the battery component to disassamle the battery component. 2) Put the lithium battery inside the component. 3) Secure the components on the device by the screws. 2. Insert the battery connecter to the battery interface on the lane control board. Note: There are battery interfaces on both of the master lane control board and slave lane control board. 16 Swing Barrier·User Manual 17 Swing Barrier·User Manual Chapter 4 Device Settings After installation and wiring completed, you should set the barriers closed position (study mode) before entering the working mode. You can also set the passing mode and memory mode, pair the remote control, initialize the hardware, switching between RS-485 communication mode and RS-232 communication mode, and view relay output NO/NC diagram by setting the DIP switch. Study Mode: The barrier will learn the closed position. Normal Mode: The device will work properly. The barrier position configured in study mode is the closed position when the device is working normally. Passing Mode: There are 9 passing modes, including controlled bi-direction, controlled entrance and prohibited exit, controlled entrance and free exit, free bi-direction, free entrance and controlled exit, free entrance and prohibited exit, prohibited bi-direction, prohibited entrance and free exit. Memory Mode: By default, the memory mode is enabled. When multiple cards are swiped and authenticated, it allows multiple persons passing through the lane. When it counts the passing people number is equal to the card swiped times, or no person passing through the lane after the last person passing, the barriers will be closed. Note: You can also set the DIP switch to control the action of swiping card to open the barrier in alarm area, entrance and exit controlling type, remote control pairing, etc. For details about the DIP switch value, see Appendix B DIP Switch Description. 4.1 Setting Closed Position Purpose: Enter the study mode through DIP switching to set the closed position of the device barrier. Steps: 1. Set The No.1 and No.2 switches of the 8-digit DIP Switch on the master lane controlling board by referring the following figure to enter the study mode. 2. Adjust the closed position of the barrier. 3. Power on the device. The device will remember the current position (closed position) automatically. 4. Power off the device. 5. Set the No.1 and No.2 switches of the 8-digit DIP Switch on the master lane controlling board by referring to the following figure. 6. Power on the device again. 18 Swing Barrier·User Manual The barrier will open automatically and turns back to the closed position. At this circumstance, the device enters the normal mode. Note: For details about the DIP switch value and meaning, see Appendix B DIP Switch Description. 4.2 Pairing Remote Control (Optional) Purpose: Pair the remote control to the device through DIP switch to open/close the barrier remotely. Note: for details about the remote control’s operations, see the related user manual. Before you start: Ask our technique supports or sales and buy the remote control. Steps: 1. Power off the swing barrier. 2. Set the No.1 switch of the 4-digit DIP Switch on the master lane control board according to the figure below. 3. Power on the swing barrier and it will enter the pairing mode. 4. Hold the Close button for more than 10 seconds. The indicator of the remote control will flash twice if the pairing is completed. Notes: You can also pair the remote control via the client software. For details, see Managing Remote Control in 6.4.6 Remote Configuration. Only one swing barrier can pair the remote control. If multiple swing barriers are in the pairing mode, the remote control will select only one of them to pair. For details about DIP switch value and meaning, see Appendix B DIP Switch Description. 4.3 Initializing Device Steps: 1. 2. 3. 4. Remove the JP11 jumper cap. Disconnect the power and reboot the device. The device buzzer buzzes a long beep. When the beep stopped, plug the jumper cap back. Disconnect the power and reboot the device. Note: The initializing of the device will restore all the parameters to the default setting and all the device events are deleted. 4.4 Switching RS-485/RS-232 Mode Take the UART2 and UART3 on the main control board as an example. If the Jumper cap’s position is like the picture displayed below. (The black part is the jumper cap.) The serial port is in RS-485 communication mode. 19 Swing Barrier·User Manual If the Jumper cap’s position is like the picture displayed below. (The black part is the jumper cap.) The serial port is in RS-232 communication mode. 4.5 Switching Relay Output Mode (NO/NC) 4.5.1 Barrier Control Relay Output Mode The pins of the barrier control relay on the main control board is as below: The jumper cap’s position of barrier opening for entrance (NO) is as below: The jumper cap’s position of barrier opening for exit (NO) is as below: The jumper cap’s position of barrier closing for entrance (NC) is as below: The jumper cap’s position of barrier closing for exit (NC) is as below: 4.5.2 Alarm Relay Output Mode (NO/NC) Alarm Relay Output Mode (NO): 20 Swing Barrier·User Manual Alarm Relay Output Mode (NC): 21 Swing Barrier·User Manual Chapter 5 Device Activation Purpose: You are required to activate the terminal first before using it. Activation via SADP, and activation via client software are supported. The default values of the control terminal are as follows. The default IP address: 192.0.0.64. The default port No.: 8000. The default user name: admin. 5.1 Activating via SADP Software SADP software is used for detecting the online device, activating the device, and resetting the password. Get the SADP software from the supplied disk or the official website, and install the SADP according to the prompts. Follow the steps to activate the control panel. Steps: 1. 2. Run the SADP software to search the online devices. Check the device status from the device list, and select an inactive device. 3. Create a password and input the password in the password field, and confirm the password. 22 Swing Barrier·User Manual STRONG PASSWORD RECOMMENDED– We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. 4. 5. Click Activate to save the password. Check the activated device. You can change the device IP address to the same network segment with your computer by either modifying the IP address manually or checking the checkbox of Enable DHCP. 6. Input the password and click the Modify button to activate your IP address modification. 5.2 Activating via Client Software The client software is versatile video management software for multiple kinds of devices. Get the client software from the supplied disk or the official website, and install the software according to the prompts. Follow the steps to activate the control panel. Steps: 1. Run the client software and the control panel of the software pops up, as shown in the figure below. 23 Swing Barrier·User Manual 2. 3. Click Device Management to enter the Device Management interface. Check the device status from the device list, and select an inactive device. 4. 5. 6. Check the device status from the device list, and select an inactive device. Click the Activate button to pop up the Activation interface In the pop-up window, create a password in the password field, and confirm the password. STRONG PASSWORD RECOMMENDED– We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. 24 Swing Barrier·User Manual 7. 8. 9. Click OK button to start activation. Click the Modify Netinfor button to pop up the Network Parameter Modification interface. Change the device IP address to the same network segment with your computer by either modifying the IP address manually. 10. Input the password and click the OK button to save the settings. 25 Swing Barrier·User Manual Chapter 6 Client Operation You can set and operate the access control devices via the client software. This chapter will introduce the access control device related operations in the client software. For integrated operations, refer to User Manual of iVMS-4200 Client Software. 6.1 Function Module Control Panel of iVMS-4200: 6.2 User Registration and Login For the first time to use iVMS-4200 client software, you need to register a super user for login. Steps: 1. Input the super user name and password. The software will judge password strength automatically, and we highly recommend you to use a strong password to ensure your data security. 2. Confirm the password. 3. Optionally, check the checkbox Enable Auto-login to log into the software automatically. 4. Click Register. Then, you can log into the software as the super user. 26 Swing Barrier·User Manual A user name cannot contain any of the following characters: / \ : * ? “ < > |. And the length of the password cannot be less than 6 characters. For your privacy, we strongly recommend changing the password to something of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. Proper configuration of all passwords and other security settings is the responsibility of the installer and/or end-user. When opening iVMS-4200 after registration, you can log into the client software with the registered user name and password. Steps: 1. Input the user name and password you registered. Note: If you forget your password, please click Forgot Password and remember the encrypted string in the pop-up window. Contact your dealer and send the encrypted string to him to reset your password. 2. Optionally, check the checkbox Enable Auto-login to log into the software automatically. 3. Click Login. After running the client software, you can open the wizards (including video wizard, video wall wizard, security control panel wizard, access control and video intercom wizard, and attendance wizard), to guide you to add the device and do other settings and operations. For detailed configuration about the wizards, please refer to the Quick Start Guide of iVMS-4200. 6.3 System Configuration Purpose: You can synchronize the missed access control events to the client. 27 Swing Barrier·User Manual Steps: 1. Click Tool – System Configuration. 2. In the System Configuration window, check the Auto-synchronize Access Control Event checkbox. 3. Set the synchronization time. The client will auto-synchronize the missed access control event to the client at the set time. 6.4 Access Control Management Purpose: The Access Control module is applicable to access control devices and video intercom. It provides multiple functionalities, including person and card management, permission configuration, access control status management, video intercom, and other advanced functions. You can also set the event configuration for access control and display access control points and zones on E-map. Note: For the user with access control module permissions, the user can enter the Access Control module and configure the access control settings. Click in the control panel, and check Access Control to add the Access Control module to the control panel. Click to enter the Access Control module. Before you start: For the first time opening the Access Control module, the following dialog will pop up and you are required to select the scene according to the actual needs. Non-residence: You can set the attendance rule when adding person, while set the access control parameters. Residence: You cannot set the attendance rule when adding person. 28 Swing Barrier·User Manual Note: Once the scene is configured, you cannot change it later. The Access Control module is composed of the following sub modules. Managing the organizations, persons, and assigning Person and Card cards to persons. Schedule and Configuring the week schedule, holiday group, and Template setting the template. Assigning access control permissions to persons and Permission applying to the devices. Providing advanced functions including access control parameters settings, card reader authentication, Advanced Function opening door with first card, anti-passing back, multi-door interlocking, and authentication password. Video intercom between client and resident, Video Intercom searching the dial log, and releasing notice. Searching history events of access control; Searching Search call logs, unlocking logs, and released notices. Device Managing the access control devices and video Management intercom devices. Note: In this chapter, we only introduce the operations about access control. 6.4.1 Adding Access Control Device Click in the Access Control module to enter the following interface. 29 Swing Barrier·User Manual Note: After adding the device, you should check the device arming status in Tool – Device Arming Control. If the device is not armed, you should arm it, or you will not receive the real-time events via the client software. For details about device arming control, refer 6.12 Arming Control. Creating Password Purpose: For some devices, you are required to create the password to activate them before they can be added to the software and work properly. Note: This function should be supported by the device. Steps: 1. Enter the Device Management page. 2. On the Device for Management or Online Device area, check the device status (shown on Security column) and select an inactive device. 3. 4. Click the Activate button to pop up the Activation interface. Create a password in the password field, and confirm the password. STRONG PASSWORD RECOMMENDED– We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, 30 Swing Barrier·User Manual resetting the password monthly or weekly can better protect your product. 5. 6. 7. 8. 9. (Optional) Enable Hik-Connect service when activating the device if the device supports. 1) Check Enable Hik-Connect checkbox to pop up the Note dialog. 2) Create a verification code. 3) Confirm the verification code. 4) Click Terms of Service and Privacy Policy to read the requirements. 5) Click OK to enable the Hik-Connect service. Click OK to activate the device. A “The device is activated.” window pops up when the password is set successfully. Click Modify Netinfo to pop up the Modify Network Parameter interface. Note: This function is only available on the Online Device area. You can change the device IP address to the same subnet with your computer if you need to add the device to the software. Change the device IP address to the same subnet with your computer by either modifying the IP address manually or checking the checkbox of DHCP. Input the password set in step 4 and click OK to complete the network settings. 31 Swing Barrier·User Manual Adding Online Device Purpose: The active online devices in the same local subnet with the client software will be displayed on the Online Device area. You can click the Refresh Every 60s button to refresh the information of the online devices. Note: You can click to hide the Online Device area. Steps: 1. Select the devices to be added from the list. Note: For the inactive device, you need to create the password for it before you can add the device properly. 2. Click Add to Client to open the device adding dialog box. 3. Input the required information. Nickname: Edit a name for the device as you want. Address: Input the device’s IP address. The IP address of the device is obtained automatically in this adding mode. Port: Input the device port No. The default value is 8000. User Name: Input the device user name. By default, the user name is admin. Password: Input the device password. STRONG PASSWORD RECOMMENDED– We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. 32 Swing Barrier·User Manual And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. 4. Optionally, check the Export to Group checkbox to create a group by the device name. You can import all the channels of the device to the corresponding group by default. Note: iVMS-4200 also provides a method to add the offline devices. 1) Check the Add Offline Device checkbox. 2) Input the required information, including the device channel number and alarm input number. 3) Click Add. When the offline device comes online, the software will connect it automatically. 5. Click Add to add the device. Adding Multiple Online Device If you want to add multiple online devices to the client software, click and hold Ctrl key to select multiple devices, and click Add to Client to open the device adding dialog box. In the pop-up message box, enter the user name and password for the devices to be added. Adding All Online Devices If you want to add all the online devices to the client software, click Add All and click OK in the pop-up message box. Then enter the user name and password for the devices to be added. 33 Swing Barrier·User Manual Adding Devices by IP or Domain Name Steps: 1. Click Add to open the device adding dialog box. 2. Select IP/Domain as the adding mode. 3. Input the required information. Nickname: Edit a name for the device as you want. Address: Input the device’s IP address or domain name. Port: Input the device port No. The default value is 8000. User Name: Input the device user name. By default, the user name is admin. Password: Input the device password. STRONG PASSWORD RECOMMENDED– We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. 4. Optionally, check the Export to Group checkbox to create a group by the device name. You can import all the channels of the device to the corresponding group by default. Note: iVMS-4200 also provides a method to add the offline devices. 1) Check the Add Offline Device checkbox. 2) Input the required information, including the device channel number and alarm input number. 3) Click Add. When the offline device comes online, the software will connect it automatically. 5. Click Add to add the device. 34 Swing Barrier·User Manual Adding Devices by IP Segment Steps: 1. Click Add to open the device adding dialog box. 2. Select IP Segment as the adding mode. 3. Input the required information. Start IP: Input a start IP address. End IP: Input an end IP address in the same network segment with the start IP. Port: Input the device port No. The default value is 8000. User Name: Input the device user name. By default, the user name is admin. Password: Input the device password. STRONG PASSWORD RECOMMENDED– We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. 4. Optionally, check the Export to Group checkbox to create a group by the device name. You can import all the channels of the device to the corresponding group by default. Note: iVMS-4200 also provides a method to add the offline devices. 1) Check the Add Offline Device checkbox. 2) Input the required information, including the device channel number and alarm input number. 3) Click Add. When the offline device comes online, the software will connect it automatically. 5. Click Add. You can add the device which the IP address is between the start IP and end IP to the device list. 35 Swing Barrier·User Manual Adding Devices by Hik-Connect Domain Purpose: You can add the devices connected via Hik-Connect by inputting the Hik-Connect account and password. Before you start: Add the devices to Hik-Connect account via iVMS-4200, iVMS-4500 Mobile Client, or Hik-Connect first. For details about adding the devices to Hik-Connect account via iVMS-4200, refer to the User Manual of iVMS-4200 Client Software. Add Single Device Steps: 1. Click Add to open the device adding dialog. 2. Select Hik-Connect Domain as the adding mode. 3. Select Single Adding. 4. Input the required information. Nickname: Edit a name for the device as you want. Device Serial No.: Input the device serial No. User Name: Input the device user name. By default, the user name is admin. Password: Input the device password. STRONG PASSWORD RECOMMENDED– We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. Hik-Connect Account: Input the Hik-Connect account. Hik-Connect Password: Input the Hik-Connect password. 5. Optionally, check the Export to Group checkbox to create a group by the device name. 36 Swing Barrier·User Manual You can import all the channels of the device to the corresponding group by default. 6. Click Add to add the device. Add Devices in Batch Steps: 1. Click Add to open the device adding dialog. 2. Select Hik-Connect Domain as the adding mode. 3. Select Batch Adding. 4. Input the required information. Hik-Connect Account: Input the Hik-Connect account. Hik-Connect Password: Input the Hik-Connect password. 5. Click Get Device List to show the devices added to Hik-Connect account. 37 Swing Barrier·User Manual 6. Check the checkbox(es) to select the device as desired. 7. Input the user name and password for the devices to be added. 8. Optionally, check the Export to Group checkbox to create a group by the device name. You can import all the channels of the device to the corresponding group by default. 9. Click Add to add the devices. Adding Devices by Serial Port Purpose: You can add access control device connected via serial port. Steps: 1. Click Add to open the device adding dialog box. 2. Select Serial Port as the adding mode. 3. Input the required information. Nickname: Edit a name for the device as you want. Serial Port No.: Select the device’s connected serial port No. 38 Swing Barrier·User Manual Baud Rate: Input the baud rate of the access control device. DIP: Input the DIP address of the device. 4. Optionally, check the Export to Group checkbox to create a group by the device name. You can import all the channels of the device to the corresponding group by default. Note: iVMS-4200 also provides a method to add the offline devices. 1) Check the Add Offline Device checkbox. 2) Input the required information, including the device channel number and alarm input number. 3) Click Add. When the offline device comes online, the software will connect it automatically. 5. Click Add to add the device. Adding Devices by IP Server Steps: 1. Click Add to open the device adding dialog box. 2. Select IP Server as the adding mode. 3. Input the required information. Nickname: Edit a name for the device as you want. Server Address: Input the IP address of the PC that installs the IP Server. Device ID: Input the device ID registered on the IP Server. User Name: Input the device user name. By default, the user name is admin. Password: Input the device password. STRONG PASSWORD RECOMMENDED– We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. 39 Swing Barrier·User Manual 4. Optionally, check the Export to Group checkbox to create a group by the device name. You can import all the channels of the device to the corresponding group by default. Note: iVMS-4200 also provides a method to add the offline devices. 1) Check the Add Offline Device checkbox. 2) Input the required information, including the device channel number and alarm input number. 3) Click Add. When the offline device comes online, the software will connect it automatically. 5. Click Add to add the device. Importing Devices in Batch Purpose: The devices can be added to the software in batch by inputting the device information in the pre-defined CSV file. Steps: 1. Click Add to open the device adding dialog box. 2. Select Batch Import as the adding mode. 3. 4. Click Export Template and save the pre-defined template (CSV file) on your PC. Open the exported template file and input the required information of the devices to be added on the corresponding column. Nickname: Edit a name for the device as you want. Adding Mode: You can input 0, 2, 3, 4, 5, or 6 which indicated different adding modes. 0 indicates that the device is added by IP address or domain name; 2 indicates that the device is added via IP server; 3 indicates that the device is added via HiDDNS; 4 indicates that the device is added via EHome protocol; 5 indicates that the device is added by serial port; 6 indicates that the device is added via Hik-Connect Domain. Address: Edit the address of the device. If you set 0 as the adding mode, you should input the IP address or domain name of the device; if you set 2 as the adding mode, you should input the IP address of the PC that installs the IP Server; if you set 3 as the adding mode, 40 Swing Barrier·User Manual you should input www.hik-online.com. Port: Input the device port No.. The default value is 8000. Device Information: If you set 0 as the adding mode, this field is not required; if you set 2 as the adding mode, input the device ID registered on the IP Server; if you set 3 as the adding mode, input the device domain name registered on HiDDNS server; if you set 4 as the adding mode, input the EHome account; if you set 6 as the adding mode, input the device serial No. User Name: Input the device user name. By default, the user name is admin. Password: Input the device password. STRONG PASSWORD RECOMMENDED– We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. Add Offline Device: You can input 1 to enable adding the offline device, and then the software will automatically connect it when the offline device comes online. 0 indicates disabling this function. Export to Group: You can input 1 to create a group by the device name (nickname). All the channels of the device will be imported to the corresponding group by default. 0 indicates disabling this function. Channel Number: If you set 1 for Add Offline Device, input the channel number of the device. If you set 0 for Add Offline Device, this field is not required. Alarm Input Number: If you set 1 for Add Offline Device, input the alarm input number of the device. If you set 0 for Add Offline Device, this field is not required. Serial Port No.: If you set 5 as the adding mode, input the serial port No. for the access control device. Baud Rate: If you set 5 as the adding mode, input the baud rate of the access control device. DIP: If you set 5 as the adding mode, input the DIP address of the access control device. Hik-Connect Account: If you set 6 as the adding mode, input the Hik-Connect account. Hik-Connect Password: If you set 6 as the adding mode, input the Hik-Connect password. 5. Click and select the template file. 6. Click Add to import the devices. The devices will be displayed on the device list for management after added successfully. You can check the resource usage, HDD status, recording status, and other information of the added devices on the list. Click Refresh All to refresh the information of all added devices. You can also input the device name in the filter field for search. 41 Swing Barrier·User Manual 6.4.2 Viewing Device Status In the device list, you can select the device and then click Device Status button to view its status. You can view the door status, host status, card reader status, alarm input status, alarm output status, arming status, DIP information, general status, active infrared intrusion detetion status, and component status. Note: The interface may different from the picture displayed above. Refer to the actual interface when adopting this function. Status Name Description Door Status Host Status View the device door’s status. View the device host’s status, including the device power supply status, anti-passing back status, host tampering status, etc. View the card reader’s status, including the online status, the tampering status, and the authentication method. View the alarm input’s status. View the alarm output’s status. View the event sensor’s status. View the arming device’s IP address and its arming type. View the device local DIP information. View the device general status, including the BUS synchronization status, IR people counting for entrance, authenticated people counting for entrance, etc. View the status of active infrared intrusion detector, receiving board, etc. Card Reader Status Alarm Input Status Alarm Output Status Event Sensor Status Arming Status DIP Information General Status Active Infrared Intrusion Detector Status 42 Swing Barrier·User Manual Component Status View the device components’ status, including the status of the motor sensor, brake status, etc. 6.4.3 Editing Basic Information Purpose: After adding the access control device, you can edit the device basic information. Steps: 1. Select the device in the device list. 2. Click Modify to pop up the modifying device information window. 3. Click Basic Information tab to enter the Basic Information interface. 4. Edit the device information, including the adding mode, the device name, the device IP address, port No., user name, and the password. 6.4.4 RS-485 Settings Purpose: You can set the RS-485 parameters including the serial port, the baud rate, the data bit, the stop bit, the parity type, the communication mode, and the working mode. Note: The RS-485 Settings should be supported by the device. Steps: 1. Select the device in the device list, and click Modify to pop up the modifying device information window. 2. Click RS-485 Settings tab to enter the RS-485 settings interface. 43 Swing Barrier·User Manual 2. Select the serial No. of the port from the dropdown list to set the RS-485 parameters. 3. Set the baud rate, data bit, the stop bit, parity type, communication mode, and working mode in the dropdown list. 4. Click Save to save the settings and the configured parameters will be applied to the device automatically. Note: After changing the working mode, the device will be rebooted. A prompt will be popped up after changing the working mode. 6.4.5 Authenticating M1 Card Encryption Before you start: You should use the specified Hikvision card enrollment station to issue card. For details, refer to Adding Person (Card) in Chapter 6.6.1 Adding Person. Purpose: The M1 Card Encryption function increases the authentication security level, which should be applied together with the card enrollment station of our company via the client software or the web client. After issuing the card, you can set the M1 card encryption function on the controller. Note: The function should be supported by the access control device and the card reader. Steps: 1. Select the device in the device list, and click Modify to pop up the modifying device information window. 2. Click M1 Card Encryption tab to enter the M1 Card Encryption interface. 3. In the M1 Card Encryption interface, check Enable checkbox to enable the M1 card encryption function. 4. Set the sector ID. 5. Click Save to save the settings. Note: The sector ID ranges from 1 to 100. 44 Swing Barrier·User Manual 6.4.6 Remote Configuration Purpose: In the device list, select the device and click Remote Configuration button to enter the remote configuration interface. You can set the detailed parameters of the selected device. Checking Device Information Steps: 1. In the device list, you can click Remote Configuration to enter the remote configuration interface. 2. Click System -> Device Information to check the device basic information and the device version information. Editing Device Name In the Remote Configuration interface, click System -> General to configure the device name and overwrite record files parameter. Click Save to save the settings. 45 Swing Barrier·User Manual Editing Time Steps: 1. In the Remote Configuration interface, click System -> Time to configure the time zone. 2. (Optional) Check Enable NTP and configure the NTP server address, the NTP port, and the synchronization interval. 3. (Optional) Check Enable DST and configure the DST star time, end time and the bias. 4. Click Save to save the settings. Setting System Maintenance Purpose: You can reboot the device remotely, restore the device to default settings, import configuration file, upgrade the device, etc. Steps: 1. In the Remote Configuration interface, click System -> System Maintenance. 2. Click Reboot to reboot the device. Or click Restore Default Settings to restore the device settings to the default ones, excluding the IP address. Or click Restore All to restore the device parameters to the default ones. The device should be activated after restoring. Note: The configuration file contains the device parameters. 3. You can also remote upgrade the device. 1) In the Remote Upgrade part, select Controller Upgrade File, Card Reader Upgrade File or Upgrade File of Lange Controller from the drop down list. 2) Upgrade File of Lange Controller from the drop down list. Controller Upgrade File: Upgrade access controller. Card Reader Upgrade File: Upgrade card reader. Only card readers connected via RS-485 can be upgraded remotely. Upgrade File of Lane Controller: Select master lane controller or slave lane controller to upgrade. 46 Swing Barrier·User Manual 3) Click to select the upgrade file. 4) Click Upgrade to start upgrading. Setting RS-485 Parameters You can set the RS-485 parameters in this page. Notes: Supports 9 peripherals: ID card reader, IC card reader, QR code scanner, fingerprint and card reader ,text screen, card recycler, fingerprint reader, and ID card identification terminal. If selecting ID card reader, QR code scanner, card recycler, text screen, or fingerprint reader as the peripheral, you should set the accessing direction. If selecting IC card reader or fingerprint reader as the external device, you should set accessing direction by setting the DIP switch. The system supports 2 authentication centers: Device and Client. 47 Swing Barrier·User Manual The authentication center type Client is mainly adopted by developers of the third party software. Managing Network User Steps: 1. In the Remote Configuration interface, click System -> User -> Network User. 2. Click Add to add the user (Do not support by the elevator controller.). Or select a user in the user list and click Edit to edit the user. You are able to edit the user password, the IP address, the MAC address and the user permission. Cilck OK to confirm editing. Managing Remote Control User Purpose: You can match the remote control’s code in this page. After the code is matched, you can control the device by the remote control. Steps: 1. In the Remote Configuration interface, click System -> User -> Remote Control User. 2. Click Add to add the user. 48 Swing Barrier·User Manual 3. Check Enable in the pop-up window and set the remote control’s serial No. 4. (Optional) Enable the Remian Open Status of the swing barrier. Note: If enabling this function, after the remote control matching completed, you can control the baffle remaining open by using the remote control. 5. Set the door open direction. 6. Click OK to save the settings. Note: You can add up to 32 remote control users. Setting Security Purpose: You can set the security parameters when logging in the device. Steps: 1. Click System -> Security. 2. Select the encryption mode in the dropdown list. You can select Compatible Mode or Encryption Mode. 3. Click Save to save the settings. Configuring Passing Parameters Purpose: You can set the passing parameters for a person to pass through the device, including the alarm triggering delay time and Triggering IR timeout period. Click System -> Passing Settings and set the parameters. Click Save to save the settings. The parameters descriptions are as follows: Valid Passing Duration: If a person has entered the lane or passed through the lane for more than the configured time duration, an alarm will be triggered. 0 represents the function is disabled. Note: The suggested minimum detection time 49 Swing Barrier·User Manual duration is 2s. Max. IR Obstructed Duration: Set the maximum time duration for the obstruction of the IR light. If the IR light is obstructed for more than the configured time duration, the alarm will be triggered. 0 represents the function is disabled. Configuring Screen Parameters Purpose: The device can connect to a text screen. You can set the display parameters on this page. Click System -> Screen Configuration and set the parameters. Click Save to save the settings. Note: For better performance, we suggest you to use the default parameters. The parameters descriptions are as follows: Screen Position: Select the screen’s position on the device. If select Exit from the drop-down list, the screen will be installed at the exit position of the device. Screen Model: Select the screen model from the drop-down list. Font Size: Select the text font size in the screen. Text Orientation: Select the text orientation on the screen. Line Spacing: Set the space between two lines. Word Spacing: Set the space between two words. Initial Position: Set the first character’s position displayed on the screen. 50 Swing Barrier·User Manual Configuring People Counting Parameters Purpose: You can set the people counting’s parameters and after the configuration. Click System -> People Counting and set the parameters. Click Save to save the settings. The parameters descriptions are as follows: Clear People Number: Click Clear and the counted people number will be restored to zero. Device People Counting: Click Enable or Disable to enable or disable the people counting function. Offline People Counting Click Enable or Disable to enable or disable function of the offline on Client: people counting on the client. If enabling the function and if the device is offline, the device will continue counting the people and the number will be stored in the device. When the device is online, the client will read the updated number from the device automatically. People Counting Type: You can select from Invalid, By IR Detection, and By Authentication Number. None: The device will not count people. If the device people counting function is enabled, the people counting function is still disabled. By IR Detection: The device will count the people who passing through the device depending on the IR detection. By Authentication The device will count the people who Number: authenticating on the device. The failed authentication will also count as once. 51 Swing Barrier·User Manual Configuring Network Parameters Click Network -> General. You can configure the NIC type, the IPv4 address, the subnet mask (IPv4), the default gateway (IPv4), MTU address, and the device port. Click Save to save the settings. Configuring Advanced Network Click Network -> Advanced Settings. You can configure the DNS 1 IP address and the DNS 2 IP address. Click Save to save the settings. Configuring Zone Parameters Steps: 1. Click Alarm -> Zone. You can view the zone parameters. 52 Swing Barrier·User Manual 2. Click to pop up the Zone Settings window. 3. Set the zone name, the zone detector type, the zone type, the sensitivity value, the linked trigger and other parameters. 4. Click Save to save the paramters. Or click Copy to… to copy the relay information to other relays. Configuring Relay Parameters Purpose: Set the main controller alarm output’s relay parameters. Steps: 5. Click Alarm -> Trigger. You can view the trigger parameters. 6. Click to pop up the Trigger Parameters Settings window. 7. Set the trigger name and the output delay. 8. Click Save to save the paramters. Or click Copy to… to copy the relay information to other relays. Configuring Audio File Purpose: You can relate the audio file to the corresponding playing scene. You can also export the audio file from the system and impor the audio file from the local. Steps: 1. Click Other -> Audio File to enter the Audio File page. Note: By default, the system contains the audio content. For details about the index related audio content, see Appendix BAppendix C Table of Audio Index Related Content. 53 Swing Barrier·User Manual 2. Select the index (the playing content) corresponded play scene. 3. (Optional) Input the descrptions of the play scene. 4. Click Save Parameters to save the relationship between the index (the playing content) and the play scene. 5. (Optional) Click Export to export the default audio file to the local computer. 6. (Optional) Clic and select audio file from the local computer. Click Import to import the file to the device. Notes: The imported audio file should be in MEM format. For details about converting other format of the audio file to MEM format, see the audio conversion manual. Operating Zone Purpose: You can arm/disarm the zone. Click Operation -> Zone to enter the Zone Operation page. Check a zone and click Arm or Disarm to control the zone. 54 Swing Barrier·User Manual Operating Relay Purpose: Open or close the device main controller alarm output’s relay. Steps: 1. Click Operation -> Relay. You can view the relay status. 2. Check the relay checkbox. 3. Click Open or Close to open or close the relay. 4. (Optional) Click Refresh to refresh the relay status. Viewing Relay Status Click Status -> Relay to view the relay status. 6.5 Organization Management You can add, edit, or delete the organization as desired. Click tab to enter the Person and Card Management interface. 55 Swing Barrier·User Manual 6.5.1 Adding Organization Steps: 1. In the organization list on the left, you should add a top organization as the parent organization of all organizations. Click Add button to pop up the adding organization interface. 2. Input the Organization Name as desired. 3. Click OK to save the adding. 4. You can add multiple levels of organizations according to the actual needs. To add sub organizations, select the parent organization and click Add. Repeat Step 2 and 3 to add the sub organization. Then the added organization will be the sub-organization of the upper-level organization. Note: Up to 10 levels of organizations can be created. 6.5.2 Modifying and Deleting Organization You can select the added organization and click Modify to modify its name. You can select an organization, and click Delete button to delete it. Notes: The lower-level organizations will be deleted as well if you delete an organization. Make sure there is no person added under the organization, or the organization cannot be deleted. 6.6 Person Management After adding the organization, you can add person to the organization and manage the added person such as issuing cards in batch, importing and exporting person information in batch, etc. Note: Up to 10,000 persons or cards can be added. 6.6.1 Adding Person Adding Person (Basic Information) Steps: 1. Select an organization in the organization list and click Add button on the Person panel to pop up the adding person dialog. 56 Swing Barrier·User Manual 2. The Person No. will be generated automatically and is not editable. 3. Input the basic information including person name, gender, phone No., birthday details, and email address. 4. Click Upload Picture to select the person picture from the local PC to upload it to the client. Note: The picture should be in *.jpg format. 5. (Optional) You can also click Take Phone to take the person’s photo with the PC camera. 6. Click OK to finish adding. Adding Person (Detailed Information) Steps: 1. In the Add Person interface, click Details tab. 2. Input the detailed information of the person, including person’s ID type, ID No., country, etc., according to actual needs. Linked Device: You can bind the indoor station to the person. 57 Swing Barrier·User Manual Note: If you select Analog Indoor Station in the Linked Device, the Door Station field will display and you are required to select the door station to communicate with the analog indoor station. Room No.: You can input the room No. of the person. 3. Click OK to save the settings. Adding Person (Permission) You can assign the permissions (including operation permissions of access control device and access control permissions) to the person when adding person. Note: For setting the access control permission, refer to Chapter 6.7 Permission Configuration. Steps: 1. In the Add Person interface, click Permission tab. 2. In the Device Operation Role field, select the role of operating the access control device. Normal User: The person has the permission to check-in/out on the device, pass the access control point, etc. Administrator: The person has the normal user permission, as well as permission to configure the device, including adding normal user, etc. 3. In the Permission(s) to Select list, all the configured permissions display. Check the permission(s) checkbox(es) and click > to add to the Selected Permission(s) list. (Optional) You can click >> to add all the displayed permissions to the Selected Permission(s) list. (Optional) In the Selected Permission(s) list, select the selected permission and click < to remove it. You can also click << to remove all the selected permissions. 4. Click OK to save the settings. Adding Person (Card) You can add card and issue the card to the person. Adding General Card Steps: 1. In the Add Person interface, click Card tab. 58 Swing Barrier·User Manual 2. Click Add to pop up the Add Card dialog. 3. Click Card to enter the Card tab. 4. Select the card type according to actual needs. Normal Card Card for Disabled Person: The door will remain open for the configured time period for the card holder. Card in Blacklist: The card swiping action will be uploaded and the door cannot be opened. Patrol Card: The card swiping action can used for checking the working status of the inspection staff. The access permission of the inspection staff is configurable. Duress Card: The door can open by swiping the duress card when there is duress. At the same time, the client can report the duress event. Super Card: The card is valid for all the doors of the controller during the configured schedule. 59 Swing Barrier·User Manual Visitor Card: The card is assigned for visitors. For the Visitor Card, you can set the Max. Swipe Times. Notes: The Max. Swipe Times should be between 0 and 255. When setting as 0, it means the card swiping is unlimited. Up to 3000 visitor cards can be added. 5. Input the password of the card itself in the Card Password field. The card password should contain 4 to 8 digits. Note: The password will be required when the card holder swiping the card to get enter to or exit from the door if you enable the card reader authentication mode as Card and Password, Password and Fingerprint, and Card, Password, and Fingerprint. For details, Chapter 6.8.2 Card Reader Authentication. 6. Click to set the effective time and expiry time of the card. 7. Select the Card Reader Mode for reading the card No. Access Controller Reader: Place the card on the reader of the Access Controller and click Read to get the card No. Card Enrollment Station: Place the card on the Card Enrollment Station and click Read to get the card No. Note: The Card Enrollment Station should connect with the PC running the client. You can click Set Card Enrollment Station to enter the following dialog. 1) Select the Card Enrollment Station type. Note: Currently, the supported card reader types include DS-K1F100-D8, DS-K1F100-M, DS-K1F100-D8E, and DS-K1F180-D8E. 2) Set the serial port No., the baud rate, the timeout value, the buzzing, or the card No. type. If the card is M1 card, and if you need to enable the M1 Card Encryption function, you should check Enable checkbox of M1 Card Encryption and click Modify to select the sector. 3) Click Save button to save the settings. You can click Restore Default Value button to restore the defaults. Manually Input: Input the card No. and click Enter to input the card No. 8. Click OK and the card(s) will be issued to the person. 60 Swing Barrier·User Manual 9. (Optional) You can select the added card and click Modify or Delete to edit or delete the card. 10. (Optional) You can generate and save the card QR code for QR code authentication. 1) Select an added card and click QR Code to generate the card QR code. 2) In the QR code pop-up window, click Download to save the QR code to the local PC. You can print the QR code for authentication on the specified device. Note: The device should support the QR code authentication function. For details about setting the QR code authentication function, see the specified device user manual. 11. (Optional) You can click Link Fingerprint to link the card with the person’s fingerprint, so that the person can place the finger on the scanner instead of swiping card when passing the door. 12. (Optional) You can click Link Face Picture to link the card with the face picture, so that the person can pass the door by scanning the face via the device instead of swiping card when passing the door. 13. Click OK to save the settings. Adding Smart Card Purpose: You can store fingerprints and ID card infomration in the smart card. When authenticating, after swiping the smart card on the device, you can scan your fingerprint or swipe your ID card on the device. The device will compare the fingerperint or ID card information in the smart card with the ones collected. If you use the smart card for authentication, there is no need to store the fingerprints or ID card information in the device in advance. Steps: 1. In the Add Person page, set the person basic information. 2. Click Card to enter the card tab. 3. Click Add to pop up the Add Card dialog. 4. Click Smart Card to enter the Smart Card tab. 61 Swing Barrier·User Manual 5. 6. Select an issuing card mode from the dropdown list. Set the external device. 1) Click Set External Device to enter the Set External Device page. 2) (Optional) Select the issuing card mode again. 3) Set a card enrollment station. 4) If you select “Fingerprint + Card No.” as the issuing mode, set the fingerprint recorder model. If you select “ID Card No. + Card No.” as the issuing mode, set the ID card reader model. If you select “Fingerprint + ID Card No. + Card No.” as the issuing mode, set the fingerprint recorder model and the ID card reader model. 5) Click OK save the settings. 7. Select a card type for the smart card. Normal Card Card for Disabled Person: The door will remain open for the configured time period for the card holder. Card in Blacklist: The card swiping action will be uploaded and the door cannot be opened. Patrol Card: The card swiping action can used for checking the working status of the inspection staff. The access permission of the inspection staff is configurable. Duress Card: The door can open by swiping the duress card when there is duress. At the same time, the client can report the duress event. Super Card: The card is valid for all the doors of the controller during the configured schedule. Visitor Card: The card is assigned for visitors. For the Visitor Card, you can set the Max. Swipe Times. Notes: The Max. Swipe Times should be between 0 and 255. When setting as 0, it means the card swiping is unlimited. Up to 3000 visitor cards can be added. Dismiss Card: Swipe the card to dismiss alarm. 8. Set other parameters of the card. 1) Set the card password. 2) Set the card effective date. 3) Scan your fingerprint and swipe your ID card according to the promt. 4) Swipe the smart card. The added card information will display in the list below. 9. Click OK and the card(s) will be issued to the person. 10. (Optional) Select the added card and click Modify or Delete to edit or delete the card. 11. (Optional) Generate and save the card QR code for QR code authentication. 1) Select an added card and click QR Code to generate the card QR code. 2) In the QR code pop-up window, click Download to save the QR code to the local PC. You can print the QR code for authentication on the specified device. Note: The device should support the QR code authentication function. For details about setting the QR code authentication function, see the specified device user manual. 12. (Optional) Click Link Fingerprint to link the card with the person’s fingerprint, so that the 62 Swing Barrier·User Manual person can place the finger on the scanner instead of swiping card when passing the door. 13. (Optional) Click Link Face Picture to link the card with the face picture, so that the person can pass the door by scanning the face via the device instead of swiping card when passing the door. 14. Click OK to save the settings. Adding Person (Face Picture) You can collect the face picture in two ways: Local Collection and Remote Collection. Local Collection: Collect the face picture via face picture scanner. Remote Collection: Collect the face picture via the access control terminal. Note: The access control terminal should support face recognition function. Steps: 4. In the Add Person interface, click Face Picture tab 5. 6. 7. 8. To get the face picture via face picture scanner: 1) Select Local Collection. 2) Connect the face picture scanner to the PC running the client. 3) Select the device type. Note: Currently, the face picture scanner of DS2CS5432B-S is supported. 4) (Optional) You can click Initialize to initialize the face picture scanner. To get the face picture via access control terminal: 1) Select Remote Collection. 2) Click Select Device to select the access control terminal which supports face recognition function. Click Collect to capture the face picture. You can click Re-Collect the captured picture again. You can click Delete to delete the captured picture. Click OK to save the settings. Adding Person (Fingerprint) Steps: 1. In the Add Person interface, click Fingerprint tab. 63 Swing Barrier·User Manual 2. Select Local Collection as desired. 3. Before inputting the fingerprint, you should connect the fingerprint machine to the PC and set its parameters first. Click Set Fingerprint Machine to enter the following dialog box. 4. 5. 6. 7. 1) Select the device type. Currently, the supported fingerprint machine types include DS-K1F800-F, DS-K1F810-F, DS-K1F820-F, and DS-K1F181-F. 2) For fingerprint machine type DS-K1F800-F, you can set the serial port number, baud rate, and overtime parameters of the fingerprint machine. 3) Click Save button to save the settings. You can click Restore Default Value button to restore the default settings. Notes: The serial port number should correspond to the serial port number of PC. You can check the serial port number in Device Manager in your PC. The baud rate should be set according to the external fingerprint card reader. The default value is 19200. Timeout after field refers to the valid fingerprint collecting time. If the user does not input a fingerprint or inputs a fingerprint unsuccessfully, the device will indicate that the fingerprint collecting is over. Click Start button, click to select the fingerprint to start collecting. Lift and rest the corresponding fingerprint on the fingerprint scanner twice to collect the fingerprint to the client. (Optional) You can also click Remote Collection to collect fingerprint from the device. Note: The function should be supported by the device. (Optional) You can select the registered fingerprint and click Delete to delete it. 64 Swing Barrier·User Manual You can click Clear to clear all fingerprints. 8. Click OK to save the fingerprints. Adding Person (Attendance Rule) You can set the attendance rule for the person. Note: This tab page will display when you select Non-Residence mode in the application scene when running the software for the first time. Steps: 1. In the Add Person interface, click Attendance Rule tab. 2. If the person joins in the time and attendance, check the Time and Attendance checkbox to enable this function for the person. Then the person’s card swiping records will be recorded and analyzed for time and attendance. For details about Time and Attendance, click More to go to the Time and Attendance module. 3. Click OK to save the settings. Importing and Exporting Person Information The person information can be imported and exported in batch. Steps: 1. Exporting Person: You can export the added persons’ information in Excel format to the local PC. 1) After adding the person, you can click Export Person button in the Person and Card tab to pop up the following dialog. 2) Click to select the path of saving the exported Excel file. 3) Check the checkboxes to select the person information to export. 65 Swing Barrier·User Manual 4) Click OK to start exporting. 2. Importing Person: You can import the Excel file with persons information in batch from the local PC 1) click Import Person button in the Person and Card tab. 2) 3) 4) 5) You can click Download Template for Importing Person to download the template first. Input the person information to the downloaded template. Click to select the Excel file with person information. Click OK to start importing. Getting Person Information from Access Control Device If the added access control device has been configured with person information (including person details, fingerprint, issued card information), you can get the person information from the device and import to the client for further operation. Note: This function is only supported by the device the connection mothod of which is TCP/IP when adding the device. Steps: 1. In the organization list on the left, click to select an organization to import the persons. 2. Click Get Person button to pop up the following dialog box. 66 Swing Barrier·User Manual 3. 4. The added access control device will be displayed. Click to select the device and then click OK to start getting the person information from the device. You can also double click the device name to start getting the person information. Notes: The person information, including person details, person’s fingerprint information (if configured), and the linked card (if configured), will be imported to the selected organization. If the person name stored in the device is empty, the person name will be filled with the issued card No. after importing to the client. The gender of the persons will be Male by default. Up to 10000 persons can be imported. 6.6.2 Managing Person Modifying and Deleting Person To modify the person information and attendance rule, click or in the Operation column, or select the person and click Modify to open the editing person dialog. You can click to view the person’s card swiping records. To delete the person, select a person and click Delete to delete it. Note: If a card is issued to the current person, the linkage will be invalid after the person is deleted. Changing Person to Other Organization You can move the person to another organization if needed. Steps: 1. Select the person in the list and click Change Organization button. 67 Swing Barrier·User Manual 2. Select the organization to move the person to. 3. Click OK to save the settings. Searching Person You can input the keyword of card No. or person name in the search field, and click Search to search the person. You can input the card No. by clicking Read to get the card No. via the connected card enrollment station. You can click Set Card Enrollment Station in the dropdown list to set the parameters. 6.6.3 Issuing Card in Batch You can issue multiple cards for the person with no card issued in batch. Steps: 1. Click Issue Card in Batch button to enter the following dialog. All the added person with no card issued will display in the Person(s) with No Card Issued list. 2. Select the card type according to actual needs. Note: For details about the card type, refer to Adding Person. 3. Input the password of the card itself in the Card Password field. The card password should contain 4 to 8 digits. Note: The password will be required when the card holder swiping the card to get enter to or exit from the door if you enable the card reader authentication mode as Card and Password, Password and Fingerprint, and Card, Password, and Fingerprint. For details, refer to Chapter 6.8.2 Card Reader Authentication. 4. Input the card quantity issued for each person. For example, if the Card Quantity is 3, you can read or enter three card No. for each person. 68 Swing Barrier·User Manual 5. 6. Click to set the effective time and expiry time of the card. In the Person(s) with No Card Issued list on the left, select the person to issue card. Note: You can click on the Person Name, Gender, and Department column to sort the persons according to actual needs. 7. Select the Card Reader Mode for reading the card No. Access Controller Reader: Place the card on the reader of the Access Controller and click Read to get the card No. Card Enrollment Station: Place the card on the Card Enrollment Station and click Read to get the card No. Note: The Card Enrollment Station should connect with the PC running the client. You can click Set Card Enrollment Station to enter the following dialog. 1) Select the Card Enrollment Station type. Note: Currently, the supported card reader types include DS-K1F100-D8, DS-K1F100-M, DS-K1F100-D8E, and DS-K1F180-D8E. 2) Set the parameters about the connected card enrollment station. If the card is M1 card, and if you need to enable the M1 Card Encryption function, you should check Enable checkbox of M1 Card Encryption and click Modify to select the sector. 3) Click Save button to save the settings. You can click Restore Default Value button to restore the defaults. Manually Input: Input the card No. and click Enter to input the card No. 8. After issuing the card to the person, the person and card information will display in the Person(s) with Card Issued list. 9. Click OK to save the settings. 6.7 Permission Configuration In Permission Configuration module, you can add, edit, and delete the access control permission, and then apply the permission settings to the device to take effect. Click icon to enter the Access Control Permission interface. 69 Swing Barrier·User Manual 6.7.1 Adding Permission Purpose: You can assign permission for persons to enter/exist the access control points (doors) in this section. Notes: You can add up to 4 permissions to one access control point of one device. You can add up to 128 permissions in total. Steps: 1. Click Add icon to enter following interface. 2. In the Permission Name field, input the name for the permission as desired. 3. Click on the dropdown menu to select a template for the permission. Note: You should configure the template before permission settings. You can click Add Template button to add the template. 4. In the Person list, all the added persons display. Check the checkbox(es) to select person(s) and click > to add to the Selected Person list. (Optional) You can select the person in Selected Person list and click < to cancel the selection. 5. In the Access Control Point/Device list, all the added access control points (doors) and door stations will display. Check the checkbox(es) to select door(s) or door station(s) and click > to add to the selected list. (Optional) You can select the door or door station in the selected list and click < to cancel the selection. 6. Click OK button to complete the permission adding. The selected person will have the permission to enter/exit the selected door/door station with their linked card(s) or fingerprints. 7. (Optional) after adding the permission, you can click Details to modify it. Or you can select the permission and click Modify to modify. 70 Swing Barrier·User Manual You can select the added permission in the list and click Delete to delete it. 6.7.2 Applying Permission Purpose: After configuring the permissions, you should apply the added permission to the access control device to take effect. Steps: 1. Select the permission(s) to apply to the access control device. To select multiple permissions, you can hold the Ctrl or Shift key and select permissions. 2. Click Apply All to start applying all the selected permission(s) to the access control device or door station. You can also click Apply Changes to apply the changed part of the selected permission(s) to the device(s). 3. The following window will pop up, indicating the applying permission result. Notes: When the permission settings are changed, the following hint box will pop up. You can click Apply Now to apply the changed permissions to the device. Or you can click Apply Later to apply the changes later in the Permission interface. The permission changes include changes of schedule and template, permission settings, person’s permission settings, and related person settings (including card No., fingerprint, face picture, linkage between card No. and fingerprint, linkage between card No. and fingerprint, card password, card effective period, etc). 71 Swing Barrier·User Manual 6.8 Advanced Functions Purpose: After configuring the person, template, and access control permission, you can configure the advanced functions of access control application, such as access control parameters, authentication password, and opening door with first card, anti-passing back, etc. Note: The advanced functions should be supported by the device. Click icon to enter the following interface. 6.8.1 Access Control Parameters Purpose: After adding the access control device, you can configure its access control point (door)’s parameters, and its card readers’ parameters. Click Access Control Parameters tab to enter the parameters settings interface. Door Parameters Steps: 1. In the controller list on the left, click to expand the access control device, select the door (access control point) and you can edit the information of the selected door on the right. 2. You can edit the following parameters: Door Magnetic: The Door Magnetic is in the status of Remain Closed (excluding special conditions). Exit Button Type: The Exit Button Type is in the status of Remain Open (excluding special 72 Swing Barrier·User Manual conditions). Door Locked Time: After swiping the normal card and relay action, the timer for locking the door starts working. Door Open Timeout Alarm: The alarm can be triggered if the door has not been close Enable Locking Door when Door Closed: The door can be locked once it is closed even if the Door Locked Time is not reached. Duress Code: The door can open by inputting the duress code when there is duress. At the same time, the client can report the duress event. Super Password: The specific person can open the door by inputting the super password. Dismiss Code: Input the dismiss code to stop the buzzer of the card reader. Notes: The duress code, Super password, and dismiss code should be different. The duress code, super password, and the dismiss code should be different from the authentication password. The duress code, super password, and the dismiss code should contain 4 to 8 numerics. 3. Click Save button to save parameters. Card Reader Parameters Steps: 1. In the device list on the left, click to expand the door, select the card reader name and you can edit the card reader parameters on the right. 2. You can edit the following parameters: Nickname: Edit the card reader name as desired. Enable Card Reader: Select Yes to enable the card reader. OK LED Polarity: Select the OK LED Polarity of the card reader mainboard. Error LED Polarity: Select the Error LED Polarity of the card reader mainboard. 73 Swing Barrier·User Manual Buzzer Polarity: Select the Buzzer LED Polarity of the card reader mainboard. Minimum Card Swiping Interval: If the interval between card swiping of the same card is less than the set value, the card swiping is invalid. You can set it as 0 to 255. Max. Interval When Inputting Password: When you inputting the password on the card reader, if the interval between pressing two digits is larger than the set value, the digits you pressed before will be cleared automatically. Enable Failed Attempts Limit of Card Reading: Enable to report alarm when the card reading attempts reach the set value. Max. Times of Card Swiping Failure: Set the max. failure attempts of reading card. Enable Tampering Detection: Enable the anti-tamper detection for the card reader. Detect When Card Reader is Offline for: When the access control device cannot connect with the card reader for longer than the set time, the card reader will turn offline automatically. Buzzing Time: Set the card reader buzzing time. The available time ranges from 0 to 5999s. 0 represents continuous buzzing. Card Reader Type: Get the card reader’s type. Card Reader Description: Get the card reader description. Fingerprint Recognition Level: Select the fingerprint recognition level in the dropdown list. By default, the level is Low. 3. Click the Save button to save parameters. Lane Controller Parameters Steps: 1. In the device list on the left, click to expand the door, select a lane controller and you can edit the lane controller’s parameters on the right. 2. You can edit the following parameters: Passing Mode: Select the controller which will control the barrier status of the device. If select According to Lane Controller’s DIP Settings, the device will follow the lane controller’s DIP settings to control the barrier. The settings on the software system will be invalid. If select According to Main Controller’s Settings, the device will follow the settings of the software system to control the barrier. The DIP settings of the lane controller will be invalid. Note: For details about setting the barrier status, see 6.11.2 Anti-control the Access Control Point (Door). 74 Swing Barrier·User Manual Enable Free Passing Authentication: If check the checkbox, when both entrance and exit’s barrier mode is Remain Open, the pedestrians should authenticate each time passing through the lane. Or an alarm will be triggered. Open/Close Door Speed: Set the barrier’s open and close speed. You can select from 1 to 10. The greater the value, the faster the speed. Note: The suggested value is 6. Alarm Audio Prompt Time Duration: Set the alarm audio prompt playing duration. Note: 0 refers to the alarm audio will be played until the alarm is ended. Temperature Unit: Select the temperature unit that displayed in the device status. Note: For details about viewing device status, see 6.4.2 Viewing Device Status. 3. Click Save to save the lane controller’s parameters. 6.8.2 Card Reader Authentication Purpose: You can set the passing rules for the card reader of the access control device. Steps: 1. Click Card Reader Authentication tab and select a card reader on the left. 2. Click Configuration button to select the card reader authentication modes for setting the schedule. Notes: The available authentication modes depend on the device type. Password refers to the card password set when issuing the card to the person in Chapter 6.6 Person Management. 1) Select the modes and click to add to the selected modes list. You can click or to adjust the display order. 3. 4. 2) Click OK to confirm the selection. After selecting the modes, the selected modes will display as icons. Click the icon to select a card reader authentication mode. Click and drag your mouse on a day to draw a color bar on the schedule, which means in that period of time, the card reader authentication is valid. 75 Swing Barrier·User Manual 5. 6. Repeat the above step to set other time periods. Or you can select a configured day and click Copy to Week button to copy the same settings to the whole week. (Optional) You can click Delete button to delete the selected time period or click Clear button to delete all the configured time periods. (Optional) Click Copy to button to copy the settings to other card readers. 7. Click Save button to save parameters. 6.8.3 Multiple Authentication Purpose: You can manage the cards by group and set the authentication for multiple cards for one access control point (door). Note: Please set the card permission and apply the permission setting to the access control device first. For details, refer to Chapter 6.7 Permission Configuration. Steps: 76 Swing Barrier·User Manual 1. Click Multiple Authentication tab to enter the following interface. 2. Select access control device from the list on the left. 3. In the Set Card Group panel on the right, click Add button to pop up the following dialog: 1) In the Card Group Name field, input the name for the group as desired. 2) Click to set the effective time and expiry time of the card group. 3) Check the checkbox(es) to select the card(s) to add the card group. 4) Click OK to save the card group. 4. In the Set Authentication Group panel, select the access control point (door) of the device for multiple authentications. 5. Input the time interval for card swiping. 6. Click Add to pop up the following dialog. 77 Swing Barrier·User Manual 1) Select the template of the authentication group from the dropdown list. 2) Select the authentication type of the authentication group from the dropdown list. Local Authentication: Authentication by the access control device. Local Authentication and Remotely Open Door: Authentication by the access control device and by the client. For Local Authentication and Remotely Open Door type, you can check the checkbox to enable the super password authentication when the access control device is disconnected with the client. Local Authentication and Super Password: Authentication by the access control device and by the super password. 3) In the list on the left, the added card group will display. You can click the card group and click to add the group to the authentication group. You can click the added card group and click to remove it from the authentication group. You can also click or to set the card swiping order. 4) Input the Card Swiping Times for the selected card group. Notes: The Card Swiping Times should be larger than 0 and smaller than the added card quantity in the card group. The upper limit of Card Swiping Times is 16. 5) Click OK to save the settings. 7. Click Save to save and take effect of the new settings. Notes: For each access control point (door), up to 20 authentication groups can be added. 78 Swing Barrier·User Manual For the authentication group which certificate type is Local Authentication, up to 8 card groups can be added to the authentication group. For the authentication group which certificate type is Local Authentication and Super Password or Local Authentication and Remotely Open Door, up to 7 card groups can be added to the authentication group. 6.8.4 Open Door with First Card Purpose: You can set multiple first cards for one access control point. After the first card swiping, it allows multiple persons access the door or other authentication actions. The first card mode contains Remain Open with First Card, Disable Remain Open with First Card, and First Card Authorization. Remain Open with First Card: The door remains open for the configured time duration after the first card swiping until the remain open duration ends. Disable Remain Open with First Card: Disable the function. First Card Authorization: All authentications (except for the authentications of super card, super password, duress card, and duress code) are allowed only after the first card authorization. Notes: The first card authorization is effective only on the current day. The authorization will be expired after 24:00 on the current day. You can swipe the first card again to disable the first card mode. Steps: 1. Click Open Door with First Card tab to enter the following interface. 2. 3. 4. Select an access control device from the list on the left. Select the first card mode in the drop-down list for the access control point. (Optional) If you select Remain Open with First Card, you should set remain open duration. Notes: The Remain Open Duration should be between 0 and 1440 minutes. By default, it is 10 minutes. 79 Swing Barrier·User Manual 5. You can swipe the first card again to disable the first card mode. In the First Card list, Click Add button to pop up the following dialog box. 6. 7. 1) Select the cards to add as first card for the door Note: Please set the card permission and apply the permission setting to the access control device first. For details, refer to Chapter 6.7 Permission Configuration. 2) Click OK button to save adding the card. You can click Delete button to remove the card from the first card list. Click Save to save and take effect of the new settings. 6.8.5 Anti-Passing Back Purpose: You can set to only pass the access control point according to the specified path and only one person could pass the access control point after swiping the card. Notes: Either the anti-passing back or multi-door interlocking function can be configured for an access control device at the same time. You should enable the anti-passing back function on the access control device first. Steps: 1. Click Anti-passing Back tab to enter the following interface. 80 Swing Barrier·User Manual 2. 3. 4. 5. 6. Select an access control device from the device list on the left. In the First Card Reader field, select the card reader as the beginning of the path. In the list, click the text filed of Card Reader Afterward and select the linked card readers. Example: If you select Reader In_01 as the beginning, and select Reader In_02, Reader Out_04 as the linked card readers. Then you can only get through the access control point by swiping the card in the order as Reader In_01, Reader In_02 and Reader Out_04. Note: Up to four afterward card readers can be added for one card reader. (Optional) You can enter the Select Card Reader dialog box again to edit its afterward card readers. Click Save to save and take effect of the new settings. 6.9 Searching Access Control Event Purpose: You can search the access control history events including remote event and local event via the client. Local Event: Search the access control event from the database of the control client. Remote Event: Search the access control event from the device. Click icon and click Access Control Event tab to enter the following interface. 81 Swing Barrier·User Manual 6.9.1 Searching Local Access Control Event Steps: 1. Select the Event Source as Local Event. 2. Input the search condition according to actual needs. 3. Click Search. The results will be listed below. 4. For the access control event which is triggered by the card holder, you can click the event to view the card holder details, including person No., person name, organization, phone number, contact address and photo. 5. (Optional) If the event contains linked pictures, you can click in the Capture column to view the captured picture of the triggered camera when the alarm is trigged. 6. (Optional) If the event contains linked video, you can click in the Playback column to view the recorded video file of the triggered camera when the alarm is trigged. Note: For setting the triggered camera, refer to Chapter 6.10.1 Access Control Event Linkage. 7. You can click Export to export the search result to the local PC in *.csv file. 6.9.2 Searching Remote Access Control Event Steps: 1. Select the Event Source as Remote Event. 2. Input the search condition according to actual needs. 82 Swing Barrier·User Manual 3. (Optional) You can check With Alarm Picture checkbox to search the events with alarm pictures. 4. Click Search. The results will be listed below. 5. You can click Export to export the search result to the local PC in *.csv file. 6.10 Access Control Event Configuration Purpose: For the added access control device, you can configure its access control linkage including access control event linkage, access control alarm input linkage, event card linkage, and cross-device linkage. Click the icon on the control panel, or click Tool->Event Management to open the Event Management page. 6.10.1 Access Control Event Linkage Purpose: You can assign linkage actions to the access control event by setting up a rule. For example, when the access control event is detected, an audible warning appears or other linkage actions happen. Note: The linkage here refers to the linkage of the client software’s own actions. Steps: 1. Click the Access Control Event tab. 2. The added access control devices will display in the Access Control Device panel on the left. Select the access control device, or alarm input, or access control point (door), or card reader to configure the event linkage. 3. Select the event type to set the linkage. 4. Select the triggered camera. The image or video from the triggered camera will pop up when the selected event occurs. To capture the picture of the triggered camera when the selected event occurs, you can also set the capture schedule and the storage in Storage Schedule. 5. Check the checkboxes to activate the linkage actions. For details, refer to Table 14.1 Linkage Actions for Access Control Event. 6. Click Save to save the settings. 7. You can click Copy to button to copy the access control event to other access control device, alarm input, access control point, or card reader. Select the parameters for copy, select the target to copy to, and click OK to confirm. 83 Swing Barrier·User Manual Table 1. 1 Linkage Actions for Access Control Event Linkage Actions Audible Warning Email Linkage Alarm Triggered Pop-up Image Descriptions The client software gives an audible warning when alarm is triggered. You can select the alarm sound for audible warning. Send an email notification of the alarm information to one or more receivers. The image with alarm information pops up when alarm is triggered. 6.10.2 Access Control Alarm Input Linkage Purpose: The access control alarm inputs can be linked to some actions (e.g., alarm output, host buzzer) when it is triggered. Note: The function should be supported by the device. Steps: 1. Click Access Control Alarm Input tab to enter the following interface. 84 Swing Barrier·User Manual 2. In the event list on the left, select an alarm input. 3. Switch the property from to to enable this action. Host Buzzer: The audible warning of controller will be triggered. Card Reader Buzzer: The audible warning of card reader will be triggered. Alarm Output: The alarm output will be triggered for notification. Access Control Point (Open/Close): The door will be open or closed when the case is triggered. Note: The door cannot be configured as open or closed at the same time. 4. Click Save button to save the settings. 6.10.3 Event Card Linkage Click Event Card Linkage tab to enter the following interface. Note: The Event Card Linkage should be supported by the device. 85 Swing Barrier·User Manual Select the access control device from the list on the left. Click Add button to add a new linkage. You can select the event source as Event Linkage or Card Linkage. Event Linkage For the event linkage, the alarm event can be divided into four types: device event, alarm input, door event, and card reader event. Steps: 1. Select a device on the left and click Add. 2. Click to select the linkage type as Event Linkage, and select the event type from the dropdown list. For Device Event, select the detailed event type from the dropdown list. For Alarm Input, select the type as alarm or alarm recovery and select the alarm input name from the panel. For Door Event, select the detailed event type and select the source door from the panel. For Card Reader Event, select the detailed event type and select the card reader from the panel. 3. Click different tabs to set different parameters. Switch the property from to to enable this function. You can set the parameters of buzzer, recording, alarm output, zone, access control point, and audio play. Linkage Type Linkage Target Descriptions Host Buzzer The audible warning of controller will be triggered. Buzzer Card Reader The audible warning of card reader will be triggered. Buzzing 86 Swing Barrier·User Manual Recording Alarm Output Capture Status Alarm Output The real-time capture will be triggered. The alarm output will be triggered for notification. The zone will be armed or disarmed according to your Zone Zone settings. The door status of open, close, remain open, and remain closed will be triggered. Notes: The door status of open, close, remain open, and Access Control Access Control remain close cannot be triggered at the same Point Point time. The target door and the source door cannot be the same one. The audio prompt will be triggered. And the select audio index related audio content will be played Audio Play Audio Play Status according to the configured play mode. Note: For details about the audio index content, see Appendix C Table of Audio Index Related Content. 4. Click Save to save and take effect of the parameters. Card Linkage Steps: 1. Click to select the linkage type as Card Linkage. 2. Input the card No. or select the card from the dropdown list. 3. Select the card reader from the panel for triggering. 5. Click different tabs to set different parameters. Switch the property from to to enable this function. You can set the parameters of buzzer, recording, alarm output, zone, access control point, and audio play. Linkage Type Linkage Target Descriptions Host Buzzer The audible warning of controller will be triggered. Buzzer Card Reader The audible warning of card reader will be triggered. Buzzing Recording Capture Status The real-time capture will be triggered. Alarm Output Alarm Output The alarm output will be triggered for notification. The zone will be armed or disarmed according to your Zone Zone settings. The door status of open, close, remain open, and remain closed will be triggered. Access Control Access Control Notes: Point Point The door status of open, close, remain open, and remain close cannot be triggered at the same 87 Swing Barrier·User Manual time. The target door and the source door cannot be the same one. The audio prompt will be triggered. And the select audio index related audio content will be played Audio Play Audio Play Status according to the configured play mode. Note: For details about the audio index content, see Appendix C Table of Audio Index Related Content. 4. Click Save to save and take effect of the parameters. 6.10.4 Cross-Device Linkage Purpose: You can assign to trigger other access control device’s action by setting up a rule when the access control event is triggered. Click Cross-Device Linkage tab to enter the following interface. Click Add button to add a new client linkage. You can select the event source as Event Linkage or Card Linkage. Event Linkage For the event linkage, the alarm event can be divided into four types: device event, alarm input, door event, and card reader event. Steps: 1. Click to select the linkage type as Event Linkage, select the access control device as event source, and select the event type from the dropdown list. For Device Event, select the detailed event type from the dropdown list. 88 Swing Barrier·User Manual For Alarm Input, select the type as alarm or alarm recovery and select the alarm input name from the table. For Door Event, select the detailed event type and select the door from the table. For Card Reader Event, select the detailed event type and select the card reader from the table. 2. Set the linkage target, select the access control device from the dropdown list as the linkage target, and switch the property from to to enable this function. Alarm Output: The alarm output will be triggered for notification. Access Control Point: The door status of open, close, remain open, and remain close will be triggered. Note: The door status of open, close, remain open, and remain close cannot be triggered at the same time. 3. Click Save button to save parameters. Card Linkage Steps: 1. Click to select the linkage type as Card Linkage. 2. Select the card from the dropdown list and select the access control device as event source. 3. Select the card reader from the table for triggering. 4. Set the linkage target, select the access control device from the dropdown list as the linkage target, and switch the property from to to enable this function. Alarm Output: The alarm output will be triggered for notification. 5. Click Save button to save parameters. 6.11 Door Status Management Purpose: The door status of the added access control device will be displayed in real time. You can check the door status and the linked event(s) of the selected door. You can control the status of the door and set the status duration of the doors as well. 6.11.1 Access Control Group Management Purpose: Before controlling the door status and setting the status duration, you are required to organize it into group for convenient management. Perform the following steps to create the group for the access control device: Steps: 1. Click on the control panel to open the Device Management page. 2. Click Group tab to enter the Group Management interface. 89 Swing Barrier·User Manual 3. Perform the following steps to add the group. 1) Click to open the Add Group dialog box. 2) Input a group name as you want. 3) Click OK to add the new group to the group list. You can also check the checkbox Create Group by Device Name to create the new group by the name of the selected device. 4. Perform the following steps to import the access control points to the group: 1) Click Import on Group Management interface, and then click the Access Control tab to open the Import Access Control page. Notes: You can also select Alarm Input tab and import the alarm inputs to group. For the Video Access Control Terminal, you can add the cameras as encoding channel to the group. 2) Select the names of the access control points in the list. 3) Select a group from the group list. 4) Click Import to import the selected access control points to the group. You can also click Import All to import all the access control points to a selected group. 90 Swing Barrier·User Manual 5. After importing the access control points to the group, you can click group/access control point name to modify it. , or double-click the 6.11.2 Anti-control the Access Control Point (Door) Purpose: You can control the status for a single access control point (a door), including opening door, closing door, remaining open, and remaining closed. Click icon on the control panel to enter the Status Monitor interface. Steps: 91 Swing Barrier·User Manual 1. 2. Select an access control group on the left. For managing the access control group, refer to Chapter 6.11.1 Access Control Group Management. The access control points of the selected access control group will be displayed on the right. Click icon on the Status Information panel to select a door. 3. Click the following button listed on the Status Information panel to control the door. : Click to open the door once. : Click to close the door once. : Click to keep the door open. : Click to keep the door closed. : Click to capture the picture manually. 4. You can view the anti-control operation result in the Operation Log panel. Notes: If you select the status as Remain Open/Remain Closed, the door will keep open/closed until a new anti-control command being made. The Capture button is available when the device supports capture function. And it cannot be realized until the storage server is configured. If the door is in remain closed status, only super card can open the door or open door via the client software. 6.11.3 Status Duration Configuration Purpose: You can schedule weekly time periods for an access control point (door) to remain open or remain closed. In the Door Status module, click Status Duration button to enter the Status Duration interface. 92 Swing Barrier·User Manual Steps: 1. Click to select a door from the access control device list on the left. 2. On the Door Status Configuration panel on the right, draw a schedule for the selected door. 1) Select a door status brush as or Remain Open: The door will keep open during the configured time period. The brush is marked as Remain Closed: The door will keep closed during the configured duration. The brush is marked as 2) Click and drag on the timeline to draw a color bar on the schedule to set the duration. 3) When the cursor turns to , you can move the selected time bar you just edited. You can also edit the displayed time point to set the accurate time period. When the cursor turns to , you can lengthen or shorten the selected time bar. 3. Optionally, you can select the schedule time bar and click Copy to Whole Week to copy the 93 Swing Barrier·User Manual time bar settings to the other days in the week. 4. You can select the time bar and click Delete Duration to delete the time period. Or you can click Clear to clear all configured durations on the schedule. 5. Click Save to save the settings. 6. You can click Copy to button to copy the schedule to other doors. 6.11.4 Real-time Card Swiping Record Click Card Swiping Record tab to enter the following interface. The logs of card swiping records of all access control devices will display in real time. You can view the details of the card swiping event, including card No., person name, organization, event time, etc. You can also click the event to view the card holder details, including person No., person name, organization, phone, contact address, etc. 6.11.5 Real-time Access Control Alarm Purpose: The logs of access control events will be displayed in real time, including device exception, door event, card reader event, and alarm input. Click Access Control Alarm tab to enter the following interface. 94 Swing Barrier·User Manual Steps: 1. All access control alarms will display in the list in real time. You can view the alarm type, alarm time, location, etc. 2. Click to view the alarm on E-map. 3. You can click trigged. or to view the live view or the captured picture of the triggered camera when the alarm is Note: For setting the triggered camera, refer to Chapter 6.10.1 Access Control Event Linkage. 4. Click Subscribe to select the alarm that the client can receive when the alarm is triggered. 1) Check the checkbox(es) to select the alarm(s), including device exception alarm, door event alarm, card reader alarm, and alarm input. 2) Click OK to save the settings. 6.12 Arming Control Purpose: 95 Swing Barrier·User Manual You can arm or disarm the device. After arming the device , the client can receive the alarm information from the device. Steps: 1. Click Tool->Device Arming Control to pop up the Device Arming Control window. 2. Arm the device by checking the corresponding checkbox. Then the alarm information will be auto uploaded to the client software when alarm occurs. 6.13 Time and Attendance Purpose: The Time and Attendance module provides multiple functionalities, including shift schedule management, attendance handling, attendance statistics and other advanced functions. Before you start: You should add organization and person in Access Control module. For details, refer to Chapter 6.5.1 Adding Organization and Chapter 6.6.1 Adding Person. Perform the following steps to access the Time and Attendance module. Click to enter the Time and Attendance module as follows: 96 Swing Barrier·User Manual 6.13.1 Shift Schedule Management Open Time and Attendance module and click Shift Schedule Management to enter the Shift Schedule Management interface. Shift Settings Purpose: You can add time period and shift for the shift schedule. Click Shift Settings to pop up Shift Settings dialog. Adding Time Period Steps: 1. Click Time Period tab. 2. Click Add. 3. Set the related parameters. Name: Set the name for time period. Start-Work / End-Work Time: Set the start-work time and end-work time. Attend at Least: Set the minimum attendance time. 97 Swing Barrier·User Manual Check-in / Check-out Required: Check the checkboxes and set the valid period for check-in or check-out. Mark as Late/Mark as Early Leave: Set the time period for late or early leave. Exclude Break Period from Work Duration: Check the checkbox and set the break period excluded. Note: Up to 3 break periods can be set. Set as Pay-per-Time Period: Check the checkbox and set the pay rate and minimum time unit. 4. Click Save to save the settings. The added time period will display on the left panel of the dialog. You can also click Delete to delete the time period. Adding Shift Steps: 1. Click Shift Tab. 2. Click Add. 3. Set the name for shift. 4. Select the shift period from the drop-down list. 5. Configure the shift period with the added time period. 1) Select the time period. 2) Click the time bar to apply the time period for the select day. You can click the time period on the bar and click or Delete to delete the period. You can also click Clear to delete all days’ time period. 6. Click Save to save the settings. The added shift will display on the left panel of the dialog. You can also click Delete on the left panel to delete the shift. Shift Schedule Settings Purpose: After setting the shift, you can set department schedule, person schedule and temporary schedule. 98 Swing Barrier·User Manual Note: The temporary schedule has higher priority than department schedule and person schedule. Department Schedule You can set the shift schedule for one department, and all the persons in the department will be assigned with the shift schedule. Note: In Time and Attendance module, the department list is the same with the organization in Access Control. For setting the organization in Access Control, refer to Chapter 6.5 Organization Management. Steps: 1. Open the Shift Schedule Management interface and select the department on the left panel. 2. Click Department Schedule to pop up Department Schedule dialog. 3. Check Time and Attendance checkbox. All persons in the department expect those excluded from attendance will apply the attendance schedule. 4. Select the shift from the drop-down list. 5. Set the start date and end date. 6. (Optional) Set other parameters for the schedule. You can select Check-in Not Required, Check-out Not Required, Effective for Holiday, Effective for Overtime, Effective for Multiple Shift Schedules. Notes: Multiple Shift Schedules contains more than one time periods. The person can check in/out in any of the time periods and the attendance will be effective. Example: If the multiple shift schedules contains three time periods: 00:00 to 07:00, 08:00 to 15:00 and 16:00 to 23:00. The attendance of the person adopting this multiple shift schedules will be effective in any of the three time periods. If the person checks in at 07:50, it will apply the nearest time period 08:00 to 15:00 to the person’s attendance. After checking the Effective for Multiple Shift Schedules checkbox, you can select the effective time period(s) from the added time periods for the persons in the department. 99 Swing Barrier·User Manual 1) In the Selectable Time Period list on the left, click the added time period and click to add it to the right. 2) (Optional) To remove the selected time period, select it and click 7. (Optional) Check Set as Default for All Persons in Department checkbox. All persons in the department will use this shift schedule by default. 8. (Optional) If the selected department contains sub department(s), the Set as Shift Schedule for All Sub Departments checkbox will display. You can check it to apply the department schedule to its sub departments. 9. Click Save to save the settings. Person Schedule Steps: 1. Open the Shift Schedule Management interface and select the department on the left panel. 2. Select the person(s) on the right panel. 3. Click Person Schedule to pop up Person Schedule dialog. 4. Check Time and Attendance checkbox. The configured person will apply the attendance schedule. 5. Select the shift from the drop-down list. 6. Set the start date and end date. 7. (Optional) Set other parameters for the schedule. You can select Check-in Not Required, Check-out Not Required, Effective for Holiday, Effective for Overtime, Effective for Multiple Shift Schedules. 8. Click Save to save the settings. Temporary Schedule Steps: 1. Open the Shift Schedule Management interface and select the department on the left panel. 2. Select the person(s) on the right panel. 3. Click Temporary Schedule to pop up Temporary Schedule dialog. 100 Swing Barrier·User Manual 4. Click to set the shift date. 5. Configure the shift date with the added time period. 1) Select the time period. 2) Click the time bar to apply the time period for the select date. You can click the time period on the bar and click to delete the period. You can also click Clear to delete all days’ time period. 6. You can click Advanced Settings to advanced attendance rules for the temporary schedule. 7. Click Add to save the settings. Checking Shift Schedule Details Steps: 1. On the Shift Schedule Management interface, select the department on the left panel. 2. Select the person(s) on the right panel. 3. Click View to pop up Shift Schedule Details dialog. You can check the shift schedule details. 101 Swing Barrier·User Manual 4. Click Normal Schedule tab. You can check and edit the normal schedule details. 1) Select the shift from the drop-down list. 2) Click Attendance Rule Settings to pop up Attendance Rule Settings dialog. You can check the attendance rules as desired and click OK to save the settings. 3) Click to set the effective date. 4) Click Save to save the settings. 5. (Optional) Click Temporary Schedule tab. 102 Swing Barrier·User Manual You can check and edit the temporary schedule details. (Optional) Click Add to add temporary schedule for the selected person. (Optional) Click to edit the time period. (Optional) Click to delete the temporary schedule. Exporting Shift Schedule Details On the Shift Schedule Management interface, select the department on the left panel and click Export to export all persons’ shift schedule details to local PC. Note: The exported details are saved in *.csv format. 6.13.2 Attendance Handling Purpose: You can handle the attendance, including check-in correction, check-out correction, leave and business trip, and manual calculation of attendance. Open Time and Attendance module and click Attendance Handling to enter the Attendance Handling interface. 103 Swing Barrier·User Manual Check-in/out Correction Purpose: You can add, edit, delete, search the check-in/out correction and generate the related report. You can also export the check-in/out correction details to local PC. Add Check-in/out Correction Steps: 1. Click Check-in/out Correction tab. 2. Click Add to pop up Add Check-in/out Correction dialog. 3. Set the check-in/out correction parameters. For Check-in Correction: Check Check-in checkbox and set the actual start-work time. For Check-out Correction: Check Check-out checkbox and set the actual end-work time. 4. Click Employee Name field and select the person. You can also input the keyword and click to search the person you want. 5. (Optional) Input the remark information as desired. 6. Click Add to add the check-in/out correction. 104 Swing Barrier·User Manual The added check-in/out correction will display on the Attendance Handling interface. (Optional) Select the check-in/out correction and click Modify to edit the correction. (Optional) Select the check-in/out correction and click Delete to delete the correction. (Optional) Click Report to generate the check-in/out correction report. (Optional) Click Export to export the check-in/out correction details to local PC. Note: The exported details are saved in *.csv format. Search Check-in/out Correction Steps: 1. Click Check-in/out Correction tab. 2. Set the searching conditions. Department: Select the department from the drop-down list. Name: Input the person name. Time: Click to set the specified time as time range. 3. Click Search to search the check-in/out corrections. The check-in/out correction details will display on the list. You can also click Reset to reset the searching conditions. 105 Swing Barrier·User Manual Appendix A Tips for Scanning Fingerprint Recommended Finger Forefinger, middle finger or the third finger. Correct Scanning The figure displayed below is the correct way to scan your finger: You should press your finger on the scanner horizontally. The center of your scanned finger should align with the scanner center. Incorrect Scanning The figures of scanning fingerprint displayed below are wrong: Vertical Edge I Side Edge II Environment The scanner should avoid direct high light, high temperature, humid conditions and rain. When it is dry, the scanner may not recognize your fingerprint successfully. You can blow your finger and scan again after drying the finger. Others If your fingerprint is shallow, or it is hard to scan your fingerprint, we recommend you to use other authentication methods. If you have injuries on the scanned finger, the scanner may not recognize. You can change another finger and try again. 106 Swing Barrier·User Manual Appendix B DIP Switch Description DIP Switch Introduction There are two groups of DIP switches on the master lane control board. Take the 8-bit DIP switch as an example; No.1 to No 8 is from the low bit to the high bit. When the switch is towards ON, it means the switch is enabled, otherwise, the switch is off. If you set the DIP switch like the figure displayed below, its binary value is 00001100, and its decimal value is 12. DIP Switch Corresponded Functions The 8-bit DIP switch corresponded functions on the master lane control board are as follows: Bit Function Decimal Value Binary Value Normal Mode 00 1 to 2 Study Mode 01 Test Mode 10 Enable Memory Mode Disable Memory Mode Allow Opening Barrier by Swiping Card in Alarm Area Prohibit Opening Barrier by Swiping Card in Alarm Area Controlled Bi-direction 0000 Controlled Entrance and 0001 Prohibit Exit Controlled Entrance and Free 0010 Exit Free Bi-direction 0011 5 to 8 Free Entrance and Controlled 0100 Exit Free Entrance and Prohibit Exit 5 0101 Prohibited Bi-direction 0110 Prohibit Entrance and 0111 Controlled Exit Prohibit Entrance and Free Exit 8 1000 107 Swing Barrier·User Manual The 4-bit DIP switch corresponded functions on the master lane control board are as follows: Bit Function Decimal Value Binary Value Normal Mode Remote Control Paring Mode 1 2~4 Reserved 108 Swing Barrier·User Manual Appendix C Table of Audio Index Related Content Index Content 10 11 13 14 Authenticated. Card No. does not exist. Card No. and fingerprint mismatch. Climbing over the barrier. Reverse passing. Passing timeout. Intrusion. Force accessing. Tailgating. No permissions. Authentication time out. Authentication failed. Expired card. 109 Swing Barrier·User Manual Appendix D Error Code Description The swing barrier will display the error code on the seven-segment display if error occurred. Refer to the table below to find the description of each number. Error Reason No. Error Reason No. Normal Working The First IR Beam on IR Board 1 Triggered The Second IR Beam on IR Board 1 Triggered The First IR Beam on IR Board 2 Triggered The Second IR Beam on IR Board 2 Triggered The First IR Beam on IR Board 3 Triggered The Second IR Beam on IR Board 3 Triggered The First IR Beam on IR Board 4 Triggered The Second IR Beam on IR Board 4 Triggered The First IR Beam on IR Board 5 Triggered The Second IR Beam on IR Board 5 Triggered The First IR Beam on IR Board 6 Triggered The Second IR Beam on IR Board 6 Triggered IR Board 1 Offline 00 IR Board 2 Offline IR Board 3 Offline 14 01 02 03 04 IR Board 4 Offline IR Board 5 Offline IR Board 6 Offline 15 16 17 18 05 Light Board Offline (Entrance) 19 06 Light Board Offline (Exit) 20 07 Adapter Offline (Up) 21 08 Adapter Offline (Low) 22 09 CAN Bus Exception 23 10 Not Studying 24 11 Obstruction 25 12 Exceeding Studying Range 26 13 Motor Exception 27 0100001080327 110 Swing Barrier·User Manual UD08974B 111
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 120 Language : en-US Producer : Microsoft® Word 2010 Creator : Microsoft® Word 2010 Create Date : 2018:03:27 10:52:26+08:00 Modify Date : 2018:03:27 10:52:26+08:00EXIF Metadata provided by EXIF.tools