SAVE THESE INSTRUCTIONS.
Owner's Manual

Installation and Operation

Model:

P35i
Pellet/Biomass
Fireplace Insert
#1-70-774195
#1-70-774235
NOTICE

DO NOT DISCARD THIS MANUAL

• Important operating and • Read, understand and • Leave this manual with
maintenance instructions 	
included.

follow these instructions
for safe installation and
operation.

WARNING

WARNING

Please read this entire manual
before installation and use of this
fireplace insert room heater.
Failure to follow these instructions
could result in property damage,
bodily injury or even death.

•	 Do not store or use gasoline or other flam-

mable vapors and liquids in the vicinity of this
or any other appliance.

•	 Do not overfire - If any external part starts to
glow, you are overfiring. Reduce feed rate.
Overfiring will void your warranty.
•	 Comply with all minimum clearances to combustibles as specified. Failure to comply may
cause a house fire.

HOT SURFACES!
Glass and other surfaces are
hot during operation AND
cool down.

Hot, will cause burns.
•	 Do not touch glass until it is cooled
•	 NEVER allow children to touch glass
•	 Keep children away
•	 CAREFULLY SUPERVISE children in same room
as fireplace.
•	 Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
flammable materials.
•	 Keep clothing, furniture, draperies and other
flammable materials away.

CAUTION

CAUTION
Tested and approved for use with wood pellets
and a mixture of shelled field corn and wood
pellets only. Burning any other type of fuel will
void your warranty.
www.harmanstoves.com

t
Do No
d
Discar

party responsible for use
and operation.

3-90-775

Check building codes prior to installation.
•	 Installation MUST comply with local, regional, state and
national codes and regulations.
•	 Consult local building, fire officials or authorities having
jurisdiction about restrictions, installation inspection, and
permits.
Rev; 7

August, 2011

P35i Fireplace Insert

Hearth & Home Technologies welcomes you to our tradition of excellence! By choosing a Harman appliance, you
have become part of a long standing family committed to meeting the heating needs of consumers with the most
distinctive, powerful and responsible home heating products available.
The P35i insert has brilliant features in an elegant package, giving you 0 to 35,000 BTU when you need it,
automatically. Aside from the regular, simple cleaning process, you need only set your desired room temperature,
keep the hopper full, and the ash pan empty. With the P35i, you will notice even heat throughout your zone and a
level of convenience you never thought possible. The P35i takes advantage of Harman’s 30+ years of stove design,
technology and manufacturing. Output is managed by a microprocessor that senses the room temperature and
the fire temperature with two thermistor probes and then determines the best feed rate for your heating demand.
The platinum combination is Harman’s Patented Pellet ProTM Feeder system, and ESP Control which have been
developed to their highest state. These features work together to allow amazing heat output with little regard for
fuel quality.
We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance.
Thank you for choosing Harman Home Heating.
When This Room Heater Is Not Properly
Installed, a House Fire May Result.
To Reduce The Risk Of Fire, Follow
The Installation Instructions. Contact
Local Building Or Fire Officials About
Restrictions And Installation Inspection
Requirements In Your Area.

Harman, A division of
Hearth & Home Technologies, Inc.
352 Mountain House Road
Halifax, PA 17032
www.harmanstoves.com

This label is located on the inside of the hopper lid.
Please record your serial number for future reference.

E
L

P
M

A
S
2

Pellets or Corn/Pellet Mixture Only

3-90-775

Save These Instructions

P35i Fireplace Insert

Safety Alert Key:

•	
•	
•	
•	

DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
CAUTION! Indicates a hazardous situation which, if not avoided could result in minor or moderate injury.
NOTICE: Indicates practices which may cause damage to the appliance or to property.

TABLE OF CONTENTS
Section 1: Listing and Code Approvals
	
	
	
	
	

A.
B.
C.
D.
E.

Appliance Certifications......................4
Mobile Home Approval.......................4
Glass Specifications...........................4
Electrical Rating ................................4
BTU & Efficiency Specifications.........4

Section 2: Special Warnings and Notes

	
A. Carbon Monoxide Warnings &
	
Considerations....................................5
	
B. Other Safety Considerations .............5
		

Section 3: Getting Started
	
	
	
	

A.
B.
C.
D.

Design, Installation & Location .........6
Fire Safety..........................................6
Component Locator .........................7
Pre-Use Checklist..............................8

Section 4: Dimensions & Clearances
	
	
	
	
	
	
	
	

A.
B.
C.
D.

Appliance Dimensions .......................9
Clearances to Combustibles.............10
Floor Protection ..............................10	
Minimum Fireplace Opening
Requirements .................................10
E. Mantel Projections ...........................10
F. Factory Built Fireplaces.....................11

	
	
	
	
	
	

A. Vent Termination Requirements ......12
B. Avoiding Smoke and Odors..............13
C. Venting Requirements / Restrictions 14	
D. Existing Fireplace Installation...........15
E. Rear Venting.....................................16
F. Zero Clearance Cabinet ..................16

Section 5: Vent Information

Section 6: Mobile Home - (US only)
	

A. Mobile Home Installation .................17

Save These Instructions

Section 7: Appliance Set-Up
	
	
	
	
	

	

	
	
	
	
	

A. Outside Air Attachment ......................18
B. Installing the Surround ......................19
C. Routing the Power Cord ....................19
D. Securing the Mounting Frame............20
E. Attaching the Venting .........................20 	
F. Installing the Body Into The Frame.....21
G. Control Board Installation ...................21
H. Room Sensor Installation ..................21
I. Optional Log Kit .................................22
J. Optional Trim Kit ................................22
K. Service Rail Kit ..................................22

Section 8: Operating Instructions
	
	

	
	
	
	
	
	
	
	

A. Fire Safety .........................................23
B. Fuel & Fuel Storage ...........................23
C. General Operating Information ..........24
D. Before Your First Fire ........................26
E. Draft Test Procedure .........................26
F. Starting a Fire "Manual" .....................26	 	
G. Starting a Fire "Automatic" ................27
H. Maintaining The Fire ..........................27
I. Relaxation Mode ................................27
J. Shut-Down Procedure ....................... 27

Section 9: Troubleshooting
	

Troubleshooting Chart..............................28

Section 10: Service & Maintenance
	
	
	
	

A.
B.
C.
D.

Shut-Down Procedure .......................29
Quick Reference Maintenance...........29
General Maintenance Procedures .....30
Motors and Components....................34

Section 11: Reference Materials
	
	
	
	
	

3-90-775

A.
B.
C.
D.
E.

Wiring Diagram ..................................38
Power Failure / Back-up ....................39
Service Parts Listing...........................40
Custom Surround Sizes......................44
Warranty Policy ..................................45
Pellets or Corn/Pellet Mixture Only

3

1

P35i Fireplace Insert

Listing and Code Approvals

A. Appliance Certification

E. BTU & Efficiency Specifications

Model:
Laboratory:
Report No.
Type: 		
		
Standard(s):

Particulate Emissions
Rating:
*BTU Input:
Heating Capacity:
Hopper Capacity#1-70-774195 (19½ ")
Hopper Capacity#1-70-774235 (23½ ")

Exempt from EPA per
40 CFR, Method 28A
0 or 6,000 - 35,000 / hr

Fuel:
Shipping Weight:

Wood pellets / Corn†
289 lbs.

P35i Insert
OMNI-Test Laboratories, Inc.
135-S-25-6.2
Solid Fuel Room Heater / Fireplace
Insert.
ASTM E1509-04, ULC S628-93 and 	
ULC/ORD C1482-M1990

This appliance is also approved for installation in
a shop.

B. Mobile Home Approved
This appliance is approved for Installation in mobile/
manufactured homes. The structural integrity of the
mobile home floor, ceiling and walls must be maintained. The appliance must be properly grounded to
the frame of the mobile home, and must never be
installed in a room designated for sleeping. The unit
must have provisions for an outside air source when
installed in a mobile home.

1,500 sq. ft.
41 lbs.
62 lbs.

* BTU input will vary, depending on the type of
fuel you use in your stove. Moisture and ash
content can affect performance.
† Corn is approved for burning only when mixed
with wood pellets.

C. Glass Specifications
This appliance is equipped with 5mm ceramic glass.
Replace glass only with 5mm ceramic glass. Please
contact your dealer for replacement glass if needed.

D. Electrical Rating
115 VAC, 60 Hz,
3.6 Amps (Start-up); avg. 1.5 Amps (Normal Run)

4

Pellets or Corn/Pellet Mixture Only

3-90-775

Save These Instructions

P35i Fireplace Insert

2

Special Warnings and Notes

Carbon monoxide, referred to as CO, is a colorless,
odorless gas that is produced during combustion of solid
fuels. CO is toxic and can be fatal.
Even though this stove is designed to be as safe
as possible, it is recommended that you install a CO
detector. This is true for oil, gas, or wood burning
products as well.
CO is not specifically heavier or lighter than air.
Therefore, it is best to install the detector at table top level
rather than on the ceiling like a smoke detector.

Never use gasoline, lantern fuel, kerosene, charcoal
lighter fluid, or similar liquids to start or “freshen up” a
fire in this heater. Keep all such liquids well away from
the heater while it is in use.

SPECIAL NOTE:

Due to ash buildup, it is strongly
recommended to have your stove
professionally cleaned and serviced
annually. This includes all parts of
the stove, and the venting system.

Save These Instructions

CO detectors are very sensitive and may sound an
alarm for fumes other than CO or CO from sources other
than the stove such as a car or lawn mower exhaust.
If the alarm sounds
1. Increase house ventilation by opening windows or
doors.
2. Make sure the stove doors and hopper lid are closed
and latched.
3. Check stove for electrical power and normal operation.
4. Check vent for possible blockage or down-draft.
5. Check for false alarm.

NEVER CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.
Installation and repair of this stove should be done
by a competent and qualified professional. We
recommend that the stove be inspected before
use and at least annually by a qualified service
person. Periodic cleaning is required throughout
the heating season and at the end of each winter
for the stove to work efficiently.

DO NOT CONNECT TO ANY AIR
DISTRIBUTION DUCT OR SYSTEM.

3-90-775

Pellets or Corn/Pellet Mixture Only

5

3

P35i Fireplace Insert

Getting Started

A. Design, Installation & Location
Considerations

B. Fire Safety

1. Appliance Location

Consideration must be given to safety, convenience,
traffic flow, and the fact that the appliance will need to
be vented to the outside. This appliance may only
be installed into an existing masonry or manufactured wood-burning fireplace or using the optional
zero-clearance cabinet to build into a newly constructed chase. It is a good idea to plan your installation on paper. Use exact measurements for clearances and floor protection, before actually beginning
the installation.
Maintain specified vent clearance to combustible
requirements listed by the vent manufacturers instructions and all appliance clearances as listed in this
manual.
Check with your local building code agency before
you begin your installation. Local codes may supersede the test laboratories specifications. Always
obtain any required permit(s) so that insurance protection benefits cannot be unexpectedly cancelled. If
any assistance is required during installation, please
contact your dealer.
We recommend that a qualified building inspector and
your insurance company representative review your
plans before and after the installation.
2. Room Sensor Location
The room sensor's location will have some effect on
the appliance's operation. When the sensor is located
close to the appliance, it may require a higher setting to keep the rest of the house comfortable. If the
sensor is located in an adjacent room, or farther away
from the stove, you will notice higher temperatures
near the appliance.

•	 Do NOT connect this unit to a chimney flue
servicing another appliance.

•	 Do NOT connect to any forced air distribution
duct or system.

Pellets or Corn/Pellet Mixture Only

To provide reasonable fire safety, the following should
be given serious consideration:
1.	 Install at least one smoke detector on each floor
of your home. Detectors should be located away
from the heating appliance and close to sleeping
areas. Follow the smoke detector manufacturer's
placement and installation instructions, and be
sure to maintain regularly.
2.	 A conveniently located Class A fire extinguisher
to contend with small fires resulting from burning
embers.
3.	 A practiced evacuation plan, consisting of at least
two escape routes.
4.	 A plan to deal with a hopper fire as follows:
In the event of a hopper fire:
a. Turn appliance to "OFF".
b. Be sure hopper lid is closed and latched.
c. Notify Fire Department.
d. Do NOT pour water in the hopper.
e. Never pull the plug or otherwise disconnect the 	
power supply to kill a fire.

WARNING
Fire Hazard
•	 Do not operate appliance before
reading and understanding the
operating instructions.
•	 Failure to operate properly may
cause a house fire.

CAUTION

6

Maintain the designated clearances to combustibles.
Insulation must not touch the chimney. You must
maintain the designated air space around the chimney. This space around a chimney is necessary to
allow natural heat removal from the area. Insulation
in this space will cause a heat buildup, which may
ignite wood framing. NOTE: Clearances may only
be reduced by means approved by the regulatory
authority having jurisdiction.

3-90-775

Save These Instructions

P35i Fireplace Insert

C. Component Locations

Hopper Lid Latch

Viewing
Glass

Ash Pan Cover
Door Latch
Return Air Slots

Control Panel

Do Not allow finish materials to block
the air flow through the return air
slots.
Combustion
Blower

Exhaust
Sensing
Probe (ESP)

Pellet Pro Feeder

Feed Motor

Distribution Blower
Save These Instructions

3-90-775

Frame Latch

Ash Pan Latch

Pellets or Corn/Pellet Mixture Only

7

P35i Fireplace Insert

D. Pre- Use Check List
1.	 	
	
	
2.	
	
	
	
3.	
	
4.	
	
5.	
	
6.	
	
7.	
	
	
8.	
	
	
	
9.	
	
10.	
	
11.	
	
12.	
	
13.	
	
	
14.	
	

8

Place the appliance in a location near the
final installation and follow the procedures
below:
Open the appliance and remove all articles
packed inside. Inspect all items for shipping
damage. Notify dealer of any missing or
damaged goods.
All safety warnings have been read and
followed precisely.
This Owner's Manual has been read in it's
entirety.
Floor protection requirements have been
read and followed.
The flue connector has been installed in
accordance with the instructions herein.
The proper clearances from the appliance
and chimney connector to combustibles
have been met.
The masonry chimney has been cleaned
and inspected by a professional, or the
factory built metal chimney is installed
according to the manufacturers instructions.
The chimney meets the minimum height
requirements.
All labels and hang tags have been removed
from the glass.
All plated surfaces have been wiped clean,
if applicable.
The room sensor and any additional cable
has been installed properly.
A properly grounded electrical receptacle is
available within reach of the unit's power
cord.
A good quality surge protector is highly
recommended to protect the electronics.

Pellets or Corn/Pellet Mixture Only

3-90-775

WARNING
Inspect appliance and components for
damage. Damaged parts may impair safe
operation.
•	
•	
•	

Do NOT install damaged components.
Do NOT install incomplete components.
Do NOT install substitute components.

Report damaged parts to dealer.

WARNING

Fire Risk.

Hearth & Home Technologies
disclaims any responsibility for, and
the warranty will be voided by, the
following actions:
•	
•	
•	

Installation and use of any damaged appliance.
Modification of the appliance.
Installation other than as instructed by Hearth &
Home Technologies.
•	 Installation of substitute materials or replacement
parts not approved by Hearth & Home Technologies
•	 Operating appliance without fully assembling all
components.
•	 Do NOT Overfire.
Or any such action that may cause a fire hazard.

Save These Instructions

P35i Fireplace Insert

4

Dimensions & Clearances

A. Appliance Dimensions

A

23.5”
59.69 cm
Hopper

19.5”
49.53 cm
Hopper

B

24”
60.96 cm
Standard Surround Oversize Surround
# 1-00-774221
# 1-00-774250
A:
40" (101.6 cm)
46" (116.8 cm)
B:
31" (78.74 cm)	
34" (86.36 cm)

22”
55.88 cm

14”
35.56 cm
2”
5.08 cm
8”
20.32 cm

Save These Instructions

10”
25.4 cm

3-90-775

Pellets or Corn/Pellet Mixture Only

9

P35i Fireplace Insert

B. Clearances To Combustibles Masonry or Manufactured Fireplace

D. Minimum Opening for Masonry 	
and Manufactured Fireplaces

The clearances specified are for your safety!
These clearances may only be reduced by
means approved by the regulatory authority.
I

H
Mantel
Face Trim

G

Side Wall

B
D
A

Location

C

F

E

Location

Inches

Millimeters

13

330

B Surround top to face trim

0

0

C Surround side to face trim

1

25.4

D Insert top to (max) 12" mantel

12

305

A Insert to combustible sidewall

Inches

Millimeters

G Minimum Width

24

609

H Minimum Depth

14.5

368

I Minimum Height #1-70-774235

23½

597

I Minimum Height #1-70-774195

19½

495

E. Mantel Projections
J

K

C. Floor Protection Requirements
Location

Inches

Millimeters

E Window opening to front

6

152

F Window opening to side

6

152

Hearth extension must be of a non-combustible material. It
must extend beyond the appliance according to the measurements listed.
Minimum Size Hearth Extension is 16" Deep By 32" Wide.
The Maximum mantel depth (J) is 12 inches (305 mm) with
a minimum vertical height (K) of 12 inches (305 mm).
10 Pellets or Corn/Pellet Mixture Only

3-90-775

Save These Instructions

P35i Fireplace Insert

F. Factory-Built Fireplace Installation
When installing the P35i Insert into a factory built
wood burning fireplace, several things need to be taken
into consideration.
The size of the fireplace opening. Will the unit fit into
the opening? Some of the factory built fireplaces have
metal smoke shields inside the top that can be removed
to gain height. Keep in mind that anything removed
from the factory built fireplace must be attached to the
fireplace with a metal wire. Floor protection guidelines,
as listed previously, must also be followed.
The manufactured fireplace may not be altered beyond the exceptions listed below. Never remove masonry
bricks or mortar from an existing fireplace.
The following modifications are permissible:
•	 Removal of the damper or lock in open position
•	 Removal of smoke shelf or baffle
•	 Removal of andirons or ember catchers
•	 Removal of log grate
•	 Removal of view screen or curtain
•	 Removal of doors
•	 External trim pieces, that do not affect the operation
of the fireplace, may be removed providing they can
be stored on or within the fireplace for reassembly if
the insert is removed.
•	 If the hearth extension is lower than the fireplace
opening, the portion of the insert extending onto the
hearth must be supported.
•	 Final approval of this type of installation is contingent
upon the authority having jurisdiction.

The factory built chimney must be listed per UL 127 (US)
and meet type HT requirements of UL 103 (US). Factory
Built fireplace chimneys tested to UL 127-98 may be, at the
fireplace manufacturers option, tested to the same criteria
as UL 103HT requirements. If the chimney is not listed as
meeting HT requirements, or if the factory built fireplace was
tested prior to 1998, a full height listed chimney liner must
be installed from the appliance flue collar to the chimney top.
Liner must meet high temperature (2100 F) per UL1777 (US).
The liner must be securely attached to both the flue collar
and the chimney cap. To prevent room air passage to the
chimney cavity of the fireplace, seal the damper area around
the chimney liner with fiberglass batting.

Hearth must be constructed to
the proper height and finished
with a non-combustible
material.

IN CANADA: This fireplace insert
must be installed with a continuous
chimney liner of a minimum 3"
diameter extending from the insert to
the top of the chimney. The chimney
liner must conform to the Class 3
requirements of CAN/ULC-S635,
Standard for Lining Systems for
Existing Masonry or Factory Built
Chimneys and Vents, or CAN/ULCS640, Standard for Lining Systems
for New Masonry Chimneys.

When using single-wall
venting or flex,this section
of venting must be wrapped
with a non-combustible
insulation to prevent excess
temperatures within the
fireplace and on the fuel
hopper.

Note: If the Harman P35i Insert is installed into a factory built wood burning fireplace, this
label (Harman part # 3-90-00675) must be attached to the altered fireplace.

Save These Instructions

3-90-775

Pellets or Corn/Pellet Mixture Only

11

5

P35i Fireplace Insert

Vent Information

Chimney connector shall not pass through an attic or roof
space, closet or similar concealed space, or a floor or ceiling.

A. Vent Termination Requirements

= Vent Termination

= Air Supply Inlet

= Restricted Area

WARNING: Venting terminals must not be recessed into
a wall or siding.
NOTE: Only PL or L vent pipe wall pass-throughs and
fire stops should be used when venting through combustible materials.
NOTE: Always take into consideration the affect the prevailing wind direction or other wind currents will cause with
flyash and /or smoke when placing the termination.
In addition, the following must be observed:
A. The clearance above grade must be a minimum of
18".1
B. The clearance to a window or door that may be opened
must be a minimum of 48" to the side and 48" below the
window/door, and 12" above the window/door.1
(with outside air installed, 18” to side and below)
C. A 12" clearance to a permanently closed window is
recommended to prevent condensation on the window.
D. The vertical clearance to a ventilated soffit located
above the terminal within a horizontal distance of 2 feet
(60 cm) from the center-line of the terminal must be a
minimum of 18".
E. The clearance to an unventilated soffit must be a
minimum of 12".
F. The clearance to an outside corner is 11" from center
of pipe.
G. The clearance to an inside corner is 12".
H. A vent must not be installed within 3 feet (90 cm)
above a gas meter/regulator assembly when measured
from the horizontal center-line of the regulator.1
12 Pellets or Corn/Pellet Mixture Only

3-90-775

I. The clearance to service regulator vent outlet must be
a minimum of 6 feet.1
J. The clearance to a non-mechanical air supply inlet to
the building or the combustion air inlet to any other appliance must be a minimum of 48”.1
K. The clearance to a mechanical air supply inlet must
be a minimum of 10 feet.1
(with outside air installed, 6 feet )
L. The clearance above a paved sidewalk or a paved
driveway located on public property must be a minimum
of 7 feet.1,2
M. The clearance under a veranda, porch, deck or balcony must be a minimum of 12 inches.1,3 (B. also)
NOTE: The clearance to vegetation and other exterior
combustibles such as mulch is 36” as measured from the
center of the outlet or cap. This 36” radius continues to
grade or a minimum of 7 feet below the outlet.
1
Certain Canadian and or Local codes or regulations
may require different clearances.
2
A vent shall not terminate directly above a side-walk or
paved driveway which is located between two single  family
dwellings and serves both dwellings.
3
Only permitted if veranda, porch, deck, or balcony is
fully open on a minimum of 2 sides beneath the floor.

NOTE: In Canada, where passage through a wall or
partition of combustible construction is desired, the
installation shall conform to CAN/CSA-B365.

Save These Instructions

P35i Fireplace Insert

B. Avoiding Smoke and Odors
Negative Pressure, Shut-down, and Power
Failure:

Vent Configurations:

To reduce the probability of back-drafting or burnback in the pellet burning appliance during power
failure or shut-down conditions, the stove must
be able to draft naturally without exhaust blower operation. Negative pressure in the house will resist this
natural draft if not accounted for in the pellet appliance
installation.
Heat rises in the house and leaks out at upper levels.
This air must be replaced with cold air from outdoors,
which flows into lower levels of the house. Vents and
chimneys into basements and lower levels of the house
can become the conduit for air supply, and reverse under
these conditions.

Outside Air:

Harman Home Heating and Hearth & Home Technologies recommend attaching outside air in all
installations, especially lower level and main floor
locations.
Per national building codes, consideration must be
given to combustion air supply to all combustion appliances. Failure to supply adequate combustion air for all
appliance demands, may lead to back-drafting of those
and other appliances.
When the appliance is side-wall vented: The air intake
is best located on the same exterior wall as the exhaust
vent outlet and located lower on the wall than the exhaust
vent outlet.
When the appliance is roof vented: The air intake is
best located on the exterior wall oriented towards the
prevailing wind direction during the heating season.
The outside air connection will supply the demands of
the pellet appliance, but consideration must be given to
the total house demand. House demand may consume
some air needed for the stove, especially during a power
failure. It may be necessary to add additional ventilation
to the space in which the pellet appliance is located.
Consult with your local HVAC professional to determine
the ventilation demands for your house.
The outside air kit consists of a flue stub pipe,
fiberglass gasket, silicone gasket, intake box and a
section of flex pipe.
An adjustable chimney intake extension, part # 1-00674104 is available to be used on masonry chimneys
only.

To reduce probability of reverse drafting during
shut-down conditions, Hearth & Home Technologies
strongly recommends:
• Installing the pellet vent with a minimum vertical
run of five feet, preferably terminating above the roof
line.
• Installing the outside air intake at least four feet
below the vent termination.
To prevent soot damage to exterior walls of the
house and to prevent re-entry of soot or ash into the
house:
• Maintain specified clearances to windows, doors,
and air inlets, including air conditioners.
• Vents should not be placed below ventilated
soffits. Run the vent above the roof.
• Avoid venting into alcove locations.
• Vents should not terminate under overhangs,
decks or onto covered porches.
• Maintain minimum clearance of 12 inches from
the vent termination to the exterior wall. If you see
deposits developing on the wall, you may need to
extend this distance to accommodate your installation
conditions.
Hearth & Home Technologies assumes no
responsibility for, nor does the warranty extend
to, smoke damage caused by reverse drafting
of pellet appliances under shut-down or power
failure conditions.

Do not connect this unit to a chimney
flue servicing another appliance.
NOTE: The restriction of not venting more than one appliance
to the same flue applies to the U.S. specifically. While it is not
recommended that you use the same chimney for more than
one appliance, in Canada certain exceptions may be made.
Be sure to contact your building code inspection official to
see if this option is allowed in your area, and to find out the
specific requirements for such an installation.

To install outside air, use kit part number 1-00-774280.
Follow the installation instructions provided with the
kit.

Save These Instructions

3-90-775

Do not connect this unit to any air
distribution duct or system.
Pellets or Corn/Pellet Mixture Only

13

P35i Fireplace Insert

C. Venting Requirements and
Restrictions
A combustion blower is used to extract the combustion gases from the firebox. This causes a negative pressure in the firebox and a positive pressure in the venting
system. The longer the vent pipe and more elbows used
in the system, the greater the flow resistance.
The recommended maximum flue lengths for the
P35i Insert are as follows:
3" or 4" Stainless Steel Flex: 30 Lineal ft. Vertical*
4" PL Vent Pipe:
4" Pl Vent Pipe: 30 Lineal ft. Vertical*
4" Pl Vent Pipe: 14 ft. Vertical w/1-90o and 12 lineal ft.
horizontal*
If additional 4" PL Vent fittings are required, the
overall length must be reduced by:
Vertical 90o or T: 	
2.5'
1.5'
Vertical 45o:		
Horizontal 90o or T: 	 5.0'
2.5'
Horizontal 45o:		
3" PL Vent Pipe:
20 Lineal ft. vertical*
8 Lineal ft. vertical w/1-90o & 8 lineal ft. horizontal*
If additional 3" PL Vent fittings are required, the
overall length must be reduced by:
Vertical 90o or T: 	
2.0'
1.0'
Vertical 45o:		
Horizontal 90o or T: 	 4.0'
2.0'
Horizontal 45o:		
* Long runs of flex or PL vent pipe installed directly
vertical from the flue stub may require more frequent
cleaning due to fly ash falling off inside and collecting
directly above the combustion blower outlet.
Any use of horizontal venting will require more
frequent cleaning. It is the responsibility of the installer
to make sure the entire flue configuration is accessible
for cleaning.
Stainless steel flex vent is only allowed for use in
masonry fireplaces and chimneys or in factory built wood
burning fireplace installations when used as a liner for
a class A metal chimney. All pellet vent pipe must be
secured together by means provided by pipe manufacturer. The vent pipe must be secured to the appliance
flue collar with a minimum of three screws.

Use only the specified venting components. Use
of any other components will void the product
warranty and may pose a hazard.
Do Not Install A Flue Damper In The Exhaust
Venting System Of This Appliance.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
NOTE: If burning a shelled corn and pellet mixture,
you must use approved venting components that
are specifically designed for corn burning.

WARNING! RISK OF FIRE!
•	 Only LISTED type L or PL Pellet venting components may be used.
•	 NO OTHER type of venting materials or components may be used.
•	 Substitute or damaged vent components may
impair safe operation.
WARNING! RISK OF INJURY OR PROPERTY 
DAMAGE!
•	 Improper installation, adjustment, alteration,
service, or maintenance can cause injury or
property damage.
•	 Read and Refer to your owner's manual.
•	 For assistance or additional information, consult a
qualified installer, service agency or your dealer.

IN CANADA: This fireplace insert must be
installed with a continuous chimney liner of a
minimum 3" diameter extending from the insert
to the top of the chimney. The chimney liner must
conform to the Class 3 requirements of CAN/ULCS635, Standard for Lining Systems for Existing
Masonry or Factory Built Chimneys and Vents, or
CAN/ULC-S640, Standard for Lining Systems for
New Masonry Chimneys.

It is also recommended that you seal all vent pipe
joints with high temperature silicone.

14 Pellets or Corn/Pellet Mixture Only

3-90-775

Save These Instructions

P35i Fireplace Insert

D. Existing Fireplace Installation:
If using a short run of venting, whether flex or rigid,
through the damper and into the chimney flue; The
Damper must be removed or locked in the open position and sealed with a plate constructed of steel or
other non-combustible material.
Kaowool, mineral wool or other non-combustible insulation is recommended above the plate to reduce the
possibility of condensation. You will also need to wrap
the venting section between the insert frame and the
damper sealing plate. This is to prevent overheating
of the fireplace cavity, which may cause damage to
the insert's motors and other electrical components.
The connector pipe should extend through the sealing
plate and smoke chamber and into, or beyond the first
flue tile.

WARNING
Fire Risk.
Inspect Chimney
•	 Masonry chimney must be in good condition
•	 Meets minimum of NFPA 211 standard
•	 Factory-built chimney must meet requirements
of UL103 HT

When venting in this configuration, a rain cap and
proper flashing must be installed on the top of the
chimney to prevent flooding and damage.

Tile Flue Liner

IN CANADA: This fireplace insert
must be installed with a continuous
chimney liner of a minimum 3"
diameter extending from the insert to
the top of the chimney. The chimney
liner must conform to the Class 3
requirements of CAN/ULC-S635,
Standard for Lining Systems for
Existing Masonry or Factory Built
Chimneys and Vents, or CAN/ULCS640, Standard for Lining Systems
for New Masonry Chimneys.

Be sure to design the venting so that it can be easily
cleaned.
Check with your local authority having jurisdiction to
determine if this venting method is acceptable. Some
Provincial, State, or Local codes may require a full
liner run to the top of the chimney. Be sure and check
your local regulations before planning the installation.
In this method, the proper flashing and rain cap are
also required.

Non-combustible
Insulation
Sealing Plate

Save These Instructions

When using single wall flex, this
section of venting must be
wrapped with non-combustible
insulation to prevent excessive
heat build-up in the cavity.

3-90-775

Pellets or Corn/Pellet Mixture Only

15

P35i Fireplace Insert
The top of the chimney must also be sealed.
Otherwise, it can become a nesting area or a
water trap.

E. Existing Fireplace, Rear Vent:

NOTE: When installed in a rear vent
configuration, the maximum BTU
may be reduced due to elevated ESP
temperatures associated with the
horizontal exhaust stream.

Masonry wall

If passing through combustible
material, the proper thimble from the
vent manufacturer must be used.

If installing using the optional zero clearance cabinet,
Item #1-00-774257, the venting will need to exit through
the top of the cabinet. The vent can be vertical or
horizontal after leaving the cabinet. Once clear of the
cabinet, a 90 degree elbow can be installed for rear
termination as shown. Do not allow vent pipe seams to
fall within the cabinet wall. Use proper wall thimble as
supplied by the venting manufacturer.
If finishing the interior with stone or masonry, the venting
can be installed without the appliance. Install the cabinet
and secure the venting using the Flue Rough-in Support
#1-00-774283.
Notice the side edges of the surround contain slotted
openings. These openings allow room air to be drawn into
the rear of the cabinet and circulated through the heat
exchange and back into the room. These openings can not
be blocked. If finishing with stone or
masonry keep the masonry a minimum
Zero Clearance Cabinet
of one inch from the sides of the
shown with Flue Rough-in
surround. Mortar can be used to give a
Support
more finished look.

16 Pellets or Corn/Pellet Mixture Only

3-90-775

Vertical Venting may be used in a constructed chase
providing all clearances to combustibles are met.

F. Optional Zero Clearance
Cabinet Installation:

Proper wall pass-thru device
as recommended by the
venting manufacturer.

3" Clearance

Vent pipe seams must be
accessible.

Save These Instructions

P35i Fireplace Insert

6

Mobile Home

A. Mobile Home Installation

CAUTION

Outside Air Kit #1-00-774280 Must be used
for installation in a mobile home.

Maintain structural integrity of mobile home:
•	 Floor, wall, ceiling and/or roof.
Do NOT cut through:
•	 Floor joist, wall studs, or ceiling trusses.
•	 Any supporting material that would affect the
structural integrity.

1.	 An outside air inlet must be provided for combustion air, and must remain clear of leaves, debris,
ice, and/or snow. The outside air path must be
unrestricted while the appliance is in operation.
2.	 The combustion air intake system must be of
metal construction. It must permit zero-clearance
to combustible materials, and contain a rodent
screen.
3.	 The appliance must be secured to the mobile
home structure by bolting it to the floor. Use the
correct length lag-bolts through the same holes
that secured the appliance to the shipping pallet.
4.	 The appliance must be grounded to the metal
framing of the mobile home.
5.	 All clearances to combustibles and floor protection
requirements must be followed.
6.	 Follow the vent manufacturer's instructions when
installing in a mobile home. Use silicone or equivalent to create an effective vapor barrier where the
chimney or other component penetrates to the
exterior of the mobile home.
7.	 Installation shall be in accordance with the Manufactured Home and Safety Standard (HUD) CFR
3280, Part 24
8.	 The appliance must never be installed in a room
designated for sleeping.
9.	 The space heater must be connected to a factory built chimney conforming to CAN/ULC-S629.
Maximum 8 inch diameter. Chimney must be
removable to allow transport of mobile home.

CAUTION
Never draw outside combustion air from:
•	 Wall, floor or ceiling cavity.
•	 Enclosed space such as an attic or garage

g
elined
v
e
l
l
L
18 sta
6 - be in
1
/
5 ay er
n
ur
Fo lts m cor
bo each
in
w
llo
s a n.)in ion
e
l
ho mi lat
us ts (2 nstal
o
r
i
l
me bo e
Nu r lag hom
fo obile
m

WARNING
Installation must comply with Manufactured
Home and Safety Standard (HUD), CFR
3280, Part 24.

WARNING
Never install in a room intended for sleeping.
Save These Instructions

There are a few holes in the bottom of the insert
mounting frame which can be used for lag bolts. Use
at least two of these holes for securing the appliance
to the fireplace floor in a mobile home installation. The
installer will need to determine and obtain the properly
sized lag bolts and masonry anchors.

3-90-775

Pellets or Corn/Pellet Mixture Only

17

7

P35i Fireplace Insert

Appliance Set-Up
The image at left shows the use of the chimney for outside air supply. Also shown is the
Chimney intake extension on the top of the
chimney. It is slotted to allow fresh air into
the flue. Be sure to use the proper flashing
and vent cap to prevent rain from entering the
chimney flue.
The image below demonstrates bringing the
outside air in through a hole cut through the
rear of the fireplace and external wall. With
this method, a screen is necessary to prevent
birds or rodents from entering.

A. Outside Air Attachment
Outside Air Kit #1-00-774280 (sold separately) must
be used for attaching outside air to the insert. This kit
contains a 3" stub and gasket to mount to the frame,
and the outside air adapter which secures to the insert
body. The outside air intake connection will seal to the
mounting frame, just like the exhaust does. Follow the
instructions included in the kit to ensure proper installation.
1.	 Make a determination of where you want to draw
the outside air from. Here are a few options.
	
a. Punch a hole through the rear of the
fireplace and exterior wall. Rigid pipe or flex
pipe could be used.
	
b. Use the chimney or chase as a conduit for 	
outside air. The exhaust liner must be run 	
the full length of the flue. When creating 	 	
your steel plate to seal the damper area,
	
Make another 3 inch hole for the outside air
	
pipe. Install a short run of pipe from the 	 	
mounting frame through the sealing plate. 	
	
Then install the chimney top extension kit,
	
item #1-00-674104 at the top of the chimney.
	
This is slotted to allow fresh air into the 	 	
chimney or chase.
2. Secure the outside air supply pipe to the stub on 	
the mounting frame using a minimum of two fas- 	
teners.
3. If running the supply pipe direct, install the outside
air cover weldment #1-10-09542 to keep birds or
rodents from entering the supply pipe.
4. Keep the intake a minimum of 4 feet (1.2 m) below 	
the exhaust termination.
---

Contents of Outside Air Kit
Stub Mounting
Bolts

Self- drilling
screws (2)

Intake Stub

Stub Gasket
Outside Air Intake
Weldment

CAUTION!
Never draw outside combustion air from:
•	 Wall, floor or ceiling cavity.
•	 Enclosed space such as an attic or garage
18 Pellets or Corn/Pellet Mixture Only

3-90-775

Save These Instructions

P35i Fireplace Insert

B. Installing the Surround

The surround consists of three panels, the top and
two sides. Follow these steps for installation:
1.	 Remove the insert body from the mounting frame;
2. Start your leveling bolts into the floor of the frame 	
and adjust to slightly raise the height.(see next 	 	
section) This will allow some clearance to 	
	
assemble the surround.
3. Prepare the side panels by removing three nuts 	
each. The left side panel is the one with the control	
board opening. If mounting the control door, the 	
hinge bracket will attach using the control panel	 	
mounting screws.
Surround Splice
Plate

Three nuts to
secure to the
frame.

4.

5.
6.

7.
8.

C. Routing the Power Cord

When choosing an electrical supply outlet, be sure
the polarity is correct, and that the supplied voltage is
within the range of 117 to 123 Volts. Surge protection
Control door
is also recommended to protect the control board
and hinge
software in the event of a surge or spike.
Once the outlet location is decided, you'll need to
Control
install and route the power cord.
Mount
At the bottom of each of the side surround panels
Brackets
is a knockout for the cord retainer. Remove the
appropriate knockout and feed
the loose wire end of the cord
into the hole. If your cord needs
to exit from the right side, route
Attach the side panels to the mounting frame by 	
the cord up the side and over
guiding the threaded studs through the holes in 	
the top of the mounting frame
the mounting frame. Slip the power cord ground 	
and back down the left side.
wire terminal over the bottom stud on the left side. 	 Attach the ground wire ring
Install the nuts onto the studs, finger tighten only.
terminal to the bottom stud
Install the top panel, making sure to close the gap 	 on the left, and use the two
with the side panels first. Tighten the nuts on the 	 hooks on the top corners of
splice brackets securely.
the mounting frame to secure
Set the mounting frame into position in the 	
	 the cord. Slip the cord clamp onto the cord right in
fireplace opening. Be sure the surround panel is 	 front of the opening in the side panel. Using a pliers,
raised slightly so that it is not supporting any of the	 compress the cord clamp and push it into the hole.
weight of the mounting frame.
When pleased with the alignment, tighten all of the 	
nuts securely.
Route Power cord away from the appliance.
There are two more holes in the splice brackets to 	
Do not run the cord under or in front of
align the outer sides of the surround panel joints. If	
the appliance.
desired, install the supplied black pop-rivets here.

Warning

Save These Instructions

3-90-775

Pellets or Corn/Pellet Mixture Only

19

P35i Fireplace Insert

D. Securing the Mounting Frame

The mounting frame is the anchor for the appliance. If the frame is not secured properly, shifting
will occur when sliding the insert in or out.
There are four (4) holes located as shown, that are
threaded for 5/16 - 18 bolts. Thread the bolts down
through the holes to raise the frame corners as
needed, to level.

E. Attaching the Venting

NOTE: When installed in a rear vent configuration, the maximum BTU
may be reduced due to elevated ESP temperatures associated with the
horizontal exhaust stream.

The mounting frame is the anchor for the appliance. If the frame is not secured properly, shifting
will occur when sliding the insert in or out.
Most importantly, the frame must be level. Again, be
certain that the surround is not supporting the weight.
Turn the leveling screws in until there is a slight gap
beneath the surround panels.
Here are a few different ways to anchor the mounting
frame.
On the sides of the frame, there are a few holes which
can be used to attach metal straps. These straps
can be anchored into the
Straps could
fireplace using masonry
attach here
anchors. You could also
use any of the unused
holes in the bottom of the
frame to install anchors
and lag bolts. Another
option involves using kit #
1-00-774279. Here, you will
mount plates to the frame.
These plates have coupling
nuts welded to them. The
kit also includes two pieces
of 1/2" all thread, which threads into the coupling nuts.
These can be used to tighten upward against the lintel
until the unit is secure.
20 Pellets or Corn/Pellet Mixture Only

3-90-775

The flue collar on the rear of the mounting frame is
designed to pivot. Loosen the four mounting bolts
and adjust the angle of the collar as needed. Shown
above is the vertical position and the horizontal
position. Be sure the fiber gasket remains in place
between the collar and the mounting frame, and
secure the bolts. Secure the first section of venting
to the collar with a minimum of two fasteners. Selfdrilling screws will work well for this. Once the
venting is secured and the seams are sealed, it is
recommended that you wrap the vent pipe with a
non-combustible insulation to prevent overheating of
the motors and other appliance components. This is
required (and supplied) when using the optional Zero
Clearance Cabinet.

Save These Instructions

P35i Fireplace Insert

F. Installing the Body into the
Mounting Frame

The rollers on the sides of the insert body will ride on
the rails of the mounting frame. Once the body is all
the way in, hook and close the top spring latches on
each side to secure.

Room sensor placed here gives an accurate measure of return air.
Push the pre-cut hole inward, and feed the sensor from the back
side. Allow the bulb of the sensor to extend approximately 1½
inches into the room. Use a wire tie on the push-in tab to secure
the sensor wire.

H. Room Sensor Installation
G. Control Board Installation
The control board is packaged in a static resistant
bag. Use care when handling, hold the circuit board
only by the edges. In a large fireplace opening, you
may have plenty of space for the circuit board to remain attached. For a smaller fireplace opening, you'll
likely need to remove the wiring from the circuit board
to route it through the side of the mounting frame and
out through the control opening. Follow these steps;
•	 Disconnect the 11 pin harness plug.
•	 Disconnect the red twisted ESP wire.
•	 Feed the harness wires and the ESP wire through
the opening in the mounting frame and out
through the control opening in the surround panel.
•	 Holding the control board outside the opening in
the surround panel, re-attach the harness plug
and the ESP wire.
•	 After determining the location of the Room Sensor (See next Section), Attach it to the two male
spade terminals near the top of the circuit board.
NOTE: These connections are not polarity specific.
•	 From the power cord, attach the green ground
wire to the grounding post located on the feeder
air intake snout.
•	 The black wire from the power cord gets attached
to the short brown wire from the control harness
•	 The white wire from the power cord will attach to
the short white wire on the control harness.
•	 Install the control panel into the surround; Right
side first, then tilt in the left side.
•	 Secure using the four black machine screws included with the surround.
Save These Instructions

Although not required, it is recommended that the
room sensor be connected in every installation. Using
a minimum size 18 gauge wire, you may splice in an
additional length, to extend the room sensor. The following are typical locations for the room sensor;
•	
•	
•	

On an interior wall next to or in place of a typical
wall thermostat.
On the leg of a coffee table or end table in your
favorite sitting location.
Sticking out through the punched hole at the lower
right corner of the control panel.

Note: When installing the room sensor externally,
limit the distance from the stove to 25 feet or less.
Once the location has been decided, run the wiring to
the control panel. You'll need to remove the two terminals from the end of the sensor cable and replace
them with the two smaller terminals from the hardware
bag. Plug the terminals into the circuit board. These
connections are not polarity specific.
Note: If the room sensor is located too close to
the appliance, or in a direct path of the distribution air, You may need to elevate the temperature
setting to maintain a comfortable temperature
level throughout the heated space.

3-90-775

See Draft Test Procedure on Page 26.
Pellets or Corn/Pellet Mixture Only

21

P35i Fireplace Insert

I. Optional Log Kit

K. Service Rail Kit- #1-00-774125

Ceramic log #3-40-674099
Log Bracket Kit #1-00-774401
Remove the two bolts from the air manifold below the
glass opening. Install the log bracket using the same
two bolts. Place the log onto the bracket with the
smaller twigs pointing back toward the burn pot.

The Service Rail Kit is used to support the insert
body while it is pulled out of the mounting frame for
cleaning or service. Used only with a raised hearth
installation, it is easily adjustable to a height range
of 4" to 14". Assemble the rail kit using the provided
instructions. After removing the Ash Pan cover, the
rails attach to the mounting frame with four bolts.
There are even stop bolts on the rails to prevent
accidental roll-off.

Please Note; The decorative log is fragile and must be
handled with care. The abrasive nature of pellet ash
may cause the log to deteriorate. Therefore, the log is
not covered under the appliance warranty.

J. Optional Trim Kit- #1-00-00775-*
The trim kit option includes a door frame and an ash
lip trim. To install the ash lip trim, simply slide it over
the ash lip from the front. You can secure it with a few
dabs of high temperature silicone, if desired. To install
the door trim, follow these steps.
•	 Remove the door latch
by loosening the small
Set-screw
set-screw and tapping
out the roll pin.
•	 Remove the door
by lifting it off of the
hinges. Lay it, face
down on a flat surface.
Roll Pin
•	 Locate and drill the
dimpled holes in each
corner of the door,
using the provided drill
bit.
•	 Install the trim frame with
the threaded studs through
the holes in the door, and
secure it with the four nuts
provided in the kit.

Two bolts on each side
secure the rail kit to the
mounting frame.

* Trim finish suffix; 4=Gold,
7=Brushed Stainless, 8=Bright Nickel

22 Pellets or Corn/Pellet Mixture Only

3-90-775

Save These Instructions

P35i Fireplace Insert

8

Operating Instructions

A. Fire Safety

•	

You can never be too cautious when it comes to fire
safety. Please give serious consideration to the following:
•	 Install at least one smoke detector and CO detector on each level of the home.
•	 Locate detectors away from the appliance and
close to the sleeping quarters.
•	 Follow the manufacturer's guidelines on placement
and installation as well as maintaining regularly.
•	 Place a Class A fire extinguisher nearby to contend with small fires.
•	 In the event of a fuel hopper fire:
•	 Evacuate the house immediately.
•	 Notify the Fire Department.

B. Fuel and Fuel Storage
Pellet fuel quality can fluctuate. This appliance is
designed to burn a wide variety of pellet fuel, giving
you the freedom to choose the most economical fuel
in your area.
Hearth & Home Technologies strongly recommends
that you choose a fuel that is recognized by the Pellet
Fuels Institute (PFI)
Pellet fuels are made from sawdust, or other wood
fibers. The source material determines the ash and
heat content. Higher ash content fuel, or Standard
Grade, may contain bark, leaves, stems, or other byproducts. Higher ash may not mean more or less heat
value, but it will require more maintenance and cleaning. Low ash content fuel, or Premium Grade, is made
from only the cleanest sawdust. Cleaning and maintenance are greatly reduced while typically higher heat
value is experienced.
APPROVED FUELS
•	 Wood Pellets- Any grade of wood or biomass pelletized fuel. Pellets should be either 1/4 inch or
5/16 inch (6 - 8mm) in diameter, and no more than
1½" (38mm) in length.

CAUTION! Do not burn fuel that contains an additive; (such as soybean oil)
•	 May cause hopper fire
•	 Damage to product may result
Read the list of ingredients on the packaging. If you
are buying field corn, the only ingredient listed should
be field corn.
CAUTION! Risk of Chemical Poisoning!
Do NOT burn treated seed corn
•	 Exhaust gases are toxic
•	 Chemicals used to treat are harmful or fatal if
ingested.
•	 Burning seed corn will void the product warranty.
STORAGE
Fuel should be stored in a dry area, preferably indoors, and well away from the appliance clearance
area.
Corn, for mixture, should be stored in a sealed container to prevent mold growth and to deter pests. Remember, corn is a food source and will attract rodents
and other pests.

Warning
"NEVER USE GASOLINE, GASOLINE-TYPE LANTERN
FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR
SIMILAR LIQUIDS TO START OR "FRESHEN UP " A
FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS
WELL AWAY FROM THE HEATER WHILE IN USE".
Save These Instructions

Shelled Field Corn- Corn is approved for use as
a fuel ONLY when mixed with pellets. The tested
mixture is up to 50% corn. Since corn is grown as
a feed source, and not as a fuel, there are many
possible inconsistencies with regards to burning.
Because of this, you may not be successful with
the maximum mixture, and may need to reduce
the percentage of corn in the mix. Corn should
have a moisture content of 15% or less. Corn for
burning should be clean and free of debris, stalks
and pieces of cob.

3-90-775

CAUTION
Tested and approved for use with wood pellets
and a mixture of shelled field corn and wood pellets ONLY. Burning of any other fuel will void your
warranty.

NOTICE
Hearth & Home Technologies is not responsible for
stove performance or extra maintenance required
as a result of using fuel with higher ash or mineral
content.
Pellets or Corn/Pellet Mixture Only

23

P35i Fireplace Insert

C. General Operating Information
The P35i's ESP control will maintain an output level to fit your temperature demands. There are two modes of
operation; "Stove Temp" mode, where the control will maintain a specified constant temperature, regardless of
the surrounding environment temperature conditions, Or "Room Temp" mode, where the control will adjust the
rate of burn to meet a specified room temperature setting. You also have the choice of Automatic or Manual
ignition. Regardless of the mode selected, operation is controlled by both, exhaust temperature- being reported
by the ESP (Exhaust Sensing Probe), and the microprocessor circuit board.
We'll discuss these control devices and their functions now.
ESP Location

1. ESP (Exhaust Sensing Probe)
The ESP is a tiny thermistor located in the exhaust stream. The probe changes it's thermal resistance based on minute changes in temperature, which is
monitored by the circuit board and used to determine the need for changes in
the burn rate to meet the temperature demand.
2. Circuit Board
As stated previously, the circuit board is a microprocessor, which means it
has the ability to "think" and adjust itself based on both, reported temperatures and demand temperature. The circuit board will also flash a code sequence on the Status light if an error is detected.

Power Light
Indicates power to the control.

Feed adjuster
Sets the maximum feed rate.
Test
Runs all motors at full speed for one
minute to check operation. Afterwards
the combustion blower will remain on
low burn voltage.

Status Light
Will be lit in either stove or room temp mode
when pointer is not within off position band
except after normal shut down. Blinks to
indicate errors detected.
Indicates power to distribution blower.

Igniter switch
Set to appropriate Start-Up mode.

Indicates power to combustion blower.
Indicates power to the feed motor.
Indicates power to the igniter.
Low Draft Adjustment Screw
(see page 26)

Temp dial
Allows you to adjust the room temperature in Room Temp
Mode using the outer scale marked in degrees Fahrenheit.
It also allows you to adjust the stove temperature while in
Stove Temp Mode using the inner scale marked from 1 to 7.

24 Pellets or Corn/Pellet Mixture Only

Dealer Diagnostic Port
For dealer maintenance only.
Requires special DDM monitor
supplied to Harman Dealers
exclusively.

3-90-775

Mode Selector
Allows you to choose between Room
Temp Mode, Stove Temp Mode, or OFF.
Also allows you to vary the distribution
blower speed by turning the knob to the
high or low side of each mode.
Distribution Blower speed adjustment
range. 	
L = low
H = high
Variable speed anywhere between L
and H; although as the stove temp.
goes up , so does the low end of the
scale.

Save These Instructions

P35i Fireplace Insert

	
a. Feed Rate Adjustment
The Circuit board runs on a one minute timer cycle.
Each minute, the board is thinking ahead to what it
needs to do for the next minute to maintain or achieve
the demanded temperature. What you are setting on
the feed adjuster dial is the maximum amount of feed
time, per minute, that you'll allow.
The circuit board will make its own determination of
how long to run the feeder, UP TO the maximum, as
set on the dial. For instance, a number 4 setting on
the feed adjuster will allow a maximum of 40 seconds
per minute of feed. If the room temperature is satisfied, with only feeding 20 seconds, then that is all the
circuit board will run the feeder. When heating a large
area, the number 4 setting is usually adequate, however, fuel quality may dictate a higher or lower setting.
If you see un-burned or burning fuel being pushed off
of the grate during a high demand period, the feed
rate is set too high. Ideally, you'll want to see about
an inch of ashes in front of the burning fuel during a
peak demand period. When the appliance is located
in a smaller room or area, the feed adjuster may need
to be kept at a lower setting of #2 or #3, to maintain a
fire with less frequent shut-down and ignition cycles.
Always allow a minimum of fifteen minutes between
making any adjustments to the feed rate.
Note: Since the circuit board is feeding as needed,
only adjust the feed rate while maximum demand
is occurring. (Stove Temp Mode, with a temp dial
setting of #7 will create maximum demand.)
	
b. Mode Selection
Room-Temp mode is the ideal mode of operation if
you wish to maintain a comfortable temperature in
the room. As the outdoor temperature fluctuates, the
control will adjust the feed rate to maintain the desired
temperature setting in the room. For best results,
be sure the room sensor is located away from drafty
areas and not positioned on the floor or near an exterior wall.
Stove-Temp mode is more of a manual method of
operation. The stove will run at a constant heat output,
regardless of surrounding air temperature. Note that
on the coldest days, your indoor heated space will be
cooler than on the warmer days. The only real benefit
to this mode of operation is that you'll be able to know
exactly how long a hopper full of fuel will last, because
the consumption is going to stay relatively the same.

Save These Instructions

	
c. Temperature Dial
The temperature dial is a dual purpose dial. In RoomTemp mode, you select the room temperature you
want the stove to maintain at the room sensor probe.
This is marked in Fahrenheit scale from 50 to 90 degrees. In Stove-Temp mode, you select a temperature
setting based on the #1 - 7 with 1 being a minimum
burn and 7 being a maximum burn rate.
	
d. Blower Speed Adjustment
The mode selector is also marked with a L to H scale
in each mode. This is a variable speed control for the
distribution blower. L is the low setting, and H is the
high setting. It is important to note that the blower will
not come on until the ESP reaches a specific temperature, to ensure that cold air is not being blown out
into the room. Also, the speed of the blower, when set
on lower speeds, will automatically increase as the
temperature of the stove increases.
	
e. Igniter Mode Switch
The toggle switch for the igniter is a two position
switch. Select from either AUTOMATIC or MANUAL.
AUTOMATIC- Will automatically start the fire in either
STOVE TEMP or ROOM TEMP mode.
	
STOVE TEMP: The ignition mode will start the
fire one time only. Since STOVE TEMP maintains a
constant output, the fire will never go out to need reignited.
	
ROOM TEMP: The ignition mode will start the
first fire. Then, if the room temperature is satisfied,
the fire will go out. Once the room cools, the ignition
mode will start another fire, and so on. This mode
provides fully automatic temperature control.
MANUAL- The fire must be started manually using
starting gel or other manufactured fire starter.
MANUAL- With the igniter switch in the manual
position, the igniter is disabled.
	
STOVE TEMP: The fire would need to be
started manually, and will maintain a constant output
based on the temperature setting.
	
ROOM TEMP: The fire would need to be
started manually. The control will adjust output to
maintain a constant room temperature, however it will
not allow the fire to go out. If the room temperature is
satisfied, the control will adjust to the minimum burn
rate and hold there until the room temperature decreases.

3-90-775

Pellets or Corn/Pellet Mixture Only

25

P35i Fireplace Insert

D. Before Your First Fire

F. Starting a Fire - "MANUAL"

•	

1.	 With the mode selector in the "OFF" position, and
the Feed Adjuster NOT on "Test", plug the power
cord into a properly grounded receptacle.
2.	 Fill the hopper with DRY fuel.
3.	 Turn the FEED ADJUSTER dial to "Test". This will
run the feed motor for one minute. If you begin to
see fuel entering the burn pot, you can stop the
test cycle. Return to #4 or #5 to start out.
4.	 Turn the mode selector dial to the desired mode.
This will start the combustion blower operating.
If Room Temp is selected, be sure to turn the
temperature dial above the current room temperature.
5.	 Fill the burn pot with a mixture of wood pellets and
starting gel.
6.	 Light the starting gel with a match, and close the
door.
7.	 Only after the ESP temperature increases, will the
feeder start operating to increase the fire size.

•	
•	
•	

Be sure the appliance is installed properly and that
all safety requirements have been met. Pay particular attention to the clearances to combustibles,
floor protection and the venting instructions.
Test your smoke detector(s) and CO detector(s) to
the specifications of the manufacturer.
Double check that the ash pan and internal firebox
are empty.
Be sure to read this entire manual.

E. Draft Test Procedure
•	

•	

•	

•	
•	
•	

•	

•	
•	

Using a 9/16" wrench, remove the draft test port
plug bolt, located to the left inside the firebox. This
bolt threads downward through the outside of the
body. Externally, the opened hole is located above
the ash pan spring latch on the left.
Insert the
draft meter
hose into the
test port.
Be sure the
meter is capable of a scale
between 0 and
1 inch Water
Column. Zero the
meter if necessary,
and be sure it is set
up to read in negative
pressure.
Be sure the ash pan, door, and hopper lid are all
closed and latched.
Turn the feed adjuster to "Test" mode.
During the first minute of test, the combustion
blower will be on high. Record the high draft
reading here ____________-W.C. The high draft
should be above -0.5" W.C. but no higher than -1"
W.C.
After a minute, the combustion blower will go to
low speed. Here you want to see a reading between -0.30" and -0.35". If necessary, adjust the
draft voltage using the low draft adjustment screw
on the circuit board (See Page 24). Clockwise
will increase the draft and counter-clockwise will
decrease it.
Once set, record the low draft reading here:_____
______ -W.C.
Be sure and turn off of "Test" mode. Disconnect
the meter and return the plug bolt to the test port.
26 Pellets or Corn/Pellet Mixture Only

3-90-775

NEVER APPLY STARTING GEL TO THE FUEL IN
THE BURN POT WITHOUT THE COMBUSTION
BLOWER OPERATING.

Warning
Tested and approved for use with wood
pellets or a mixture of shelled corn and
pellets only. use of any other type of fuel
will void the appliance warranty.

Warning
"NEVER USE GASOLINE, GASOLINE-TYPE
LANTERN FUEL, KEROSENE, CHARCOAL
LIGHTER FLUID, OR SIMILAR LIQUIDS TO
START OR "FRESHEN UP " A FIRE IN THIS
HEATER. KEEP ALL SUCH LIQUIDS WELL AWAY
FROM THE HEATER WHILE IN USE".

The optimal method of operation is in Room Temp
mode, with the Ignition switch set to Automatic.

Save These Instructions

P35i Fireplace Insert

G. Starting a Fire - "AUTOMATIC"

I. Relaxation Mode

1.	 With the mode selector in the "OFF" position, and
the Feed Adjuster NOT on "Test", plug the power
cord into a properly grounded receptacle.
2.	 Fill the hopper with DRY fuel.
3.	 Turn the FEED ADJUSTER dial to "Test". This will
run the feed motor for one minute. If you begin to
see fuel entering the burn pot, you can stop the
test cycle. Return to #4 or #5 to start out.
4.	 Position the Igniter switch to AUTOMATIC.
5.	 Turn the mode selector dial to the desired mode.
This will start the combustion blower, feeder, and
igniter operating. If Room Temp is selected, be
sure to turn the temperature dial above the
current room temperature.
6.	 After the initial feed cycle is typically when you'll
begin to see sparks, smoke, or flames.

An added feature for those times when you'd like to
unwind watching a fire but yet do not want all the heat.
With the igniter switch in the "MANUAL" position and
the mode selector in "STOVE TEMP", your temperature dial can be set up to a #3 and the distribution
blower will be disabled. As you turn up the temperature dial and the fire
begins to burn hotter,
the distribution blower
will begin to operate.

Keep Hopper Lid, Ash Pan, and Fire viewing doors
closed while in operation. Maintain all door seals
and gaskets in good condition. Replace gaskets
when necessary using parts obtained through
your Harman dealer.

H. Maintaining the Fire
Once the Distribution Blower begins operation, your
fire is well established. Now, you can make any
desired adjustments to the temperature dial. Remember, in STOVE TEMP, the temperature dial uses the
inner portion of the scale (#1 thru 7). In ROOM TEMP,
select the desired temperature in Fahrenheit from 50
to 90 degrees.
The flames should appear brisk and bright. If you see
deep orange and lazy flames, it is usually an indication that the burn pot needs to be cleaned. Refer to
the Maintenance Section of this manual.
WARNING!  RISK OF FIRE! Keep combustible materials, gasoline, and other flammable vapors or liquids
clear of this appliance.
•	 Do NOT store flammable materials in the vicinity
of this appliance.
•	 DO NOT BURN GARBAGE OR FLAMMABLE
FLUIDS SUCH AS GASOLINE, NAPTHA OR
ENGINE OIL.
•	 DO NOT USE CHEMICALS OR FLUIDS TO
START A FIRE.
Keep all such liquids well away from the heater while
it is in use, combustible materials may ignite!
Save These Instructions

J. Shut-Down
During operation in ROOM TEMP/ AUTOMATIC
mode, the appliance will shut down naturally when
demand is met or exceeded. In other modes of operation, the unit will shut-down only if or when it runs out
of fuel.
To kill or stop a fire, turn the mode selector dial to
"OFF". The shut down cycle will slow or stop the
feeder to gradually cool the fire and ensure that all of
the exhaust gases are safely expelled before stopping
the combustion blower. This not only ensures removal
of all smoke and gases, it also keeps the fire from attempting to travel into the fuel storage hopper. For this
reason; Hearth & Home Technologies recommends
installing a battery back-up in areas where frequent
power outages are experienced. (Also see page13)
NEVER ATTEMPT TO KILL A FIRE BY PULLING
THE PLUG OR OTHERWISE DISCONNECTING THE
ELECTRICITY SUPPLY.
The best way to kill a fire, especially at the end of the
heating season, is to simply allow it to run out of fuel.

3-90-775

Pellets or Corn/Pellet Mixture Only

27

9

P35i Fireplace Insert

Troubleshooting
Error Message 		

With proper installation, operation, and maintenance, your appliance will provide years of
trouble-free service. If you do experience a problem, this troubleshooting guide will assist a
qualified service person in proper diagnosis and repair. This guide is intended for qualified
service technician use only.

Possible Cause 			

Broken probe, wire or connection.

3-Blinks; Poor ESP signal.

Corrective Action
Check connection / Replace Probe

Exhaust temperature has gone out of range Clean exhaust- possible soot or creosote
multiple times.
accumulation near probe.
4-Blinks; Poor Room Sensor 	
signal.

5-Blinks; Failed ignition

Broken sensor, wire or connection.

Check connection / Replace sensor

No fuel in hopper

Load fuel

Door, hopper lid, or ash pan open

Close all doors and check seals

Poor draft / weak combustion blower

Perform draft test, clean exhaust, replace blower if
necessary.
Check operation in "Test" mode. Clear obstruction

Fuel feed restriction

6-Blinks; Poor combustion

Blocked airflow / Igniter failure

Open burn pot cleanout to access igniter- clean.
Check igniter, replace if necessary

No fuel in hopper

Load fuel

Door, hopper lid, or ash pan open

Close all doors and check seals

Poor draft / weak combustion blower

Perform draft test, clean exhaust, replace blower if
necessary.
Check operation in "Test" mode. Clear obstruction

Fuel feed restriction

Symptom

		

Low volume or no fuel feed

Possible Cause 			

No fuel in hopper

Load fuel

Door, hopper lid, or ash pan open

Close all doors and check seals

Poor draft / weak combustion blower
Fuel feed restriction

Perform draft test, clean exhaust, replace blower if
necessary.
Check operation in "Test" mode. Clear obstruction

Failed feed motor

Replace motor if necessary

Fire isn't hot enough for blower operation

Increase temperature setting

MANUAL / STOVE TEMP

When operating in manual ignite / stove temp mode,
the blower will not run below a #3 setting on the
temperature dial. Increase temperature setting.

Failed motor or connections- "Test" mode

Check connections / Replace blower

Feed rate too low

Set feed adjuster at #4 or higher

Room sensor location different than thermometer location

Room sensor reports the room air temperature to
the circuit board. Move sensor location or adjust set
point accordingly

Excessive ash buildup on heat exchanger
or in the exhaust

Clean exhaust, firebox, and heat exchanger thoroughly.

No Distribution Blower

Low heat output, or room temperature doesn't match thermometer or other readings

Corrective Action

28 Pellets or Corn/Pellet Mixture Only

3-90-775

Save These Instructions

P35i Fireplace Insert

10

Service & Maintenance
Soot- Formation and Need For Removal-

A. Shut-down Procedure
The best way to shut down the appliance is to simply
let it run out of fuel, and shut down naturally as the
temperature cools. This method is highly recommended for the end of season shut-down.
To shut-down otherwise, turn the mode selector to
"OFF' verify by ensuring that the Status light goes out.
The shut-down protocol of the circuit board will safely
allow the fire to go out. All motors will stop when cool,
and only the POWER light will remain lit. It is now safe
to un-plug the electrical supply.
CAUTION! SHOCK AND SMOKE HAZARD!
Proper Shut-down procedure must be followed.
•	 Smoke spillage may occur if shut-down is not
complete
•	 Risk of shock if appliance is not disconnected from
the supply power prior to servicing.

When wood is burned, the products of combustion
combine with moisture to form a soot residue which
accumulates on the flue lining. When ignited, this
soot makes an extremely hot fire. The entire venting
system should be inspected at least once every two
months during the heating season to determine if a
soot buildup has occurred. If soot has accumulated,
it should be removed to reduce the risk of a chimney
fire.
If you experience a chimney fire; Turn the control
to "Off". Keep appliance doors and hopper lid closed
and latched. Notify the fire department. Do not operate the appliance until the chimney and connector
have been inspected and approved by a chimney
professional.

B. Quick Reference Maintenance Chart
Follow the detailed instructions found in this section for each point listed in the chart below.
NOTICE: For recommendation purposes only - More frequent cleaning is necessary if heavy buildup is
encountered at the recommended intervals, or if you see soot coming from the vent. Failure to clean your
appliance on a regular basis will void the product warranty.
Cleaning or Inspection

Frequency

Daily Weekly Monthly Yearly

Area beneath burn pot grate /
Igniter

After each ton of fuel burned

OR

Ash removal

Depending on fuel quality

OR

Burn pot grate surface

Depending on fuel quality

OR

Combustion blower / paddle fan

After each ton of fuel burned

OR

Distribution blower

More frequently depending on
surroundings

OR

Door latch inspection

Prior to heating season

OR

Feeder body / Fines collection area Depending on fuel quality

OR

Firebox / thorough cleaning

After each ton of fuel burned

OR

Glass

When view of fire becomes
obstructed

OR

Heat exchanger

After each ton of fuel burned

OR

Hopper

Whenever adding fuel

OR

Venting system

More frequently depending on
fuel quality and quantity

OR

Save These Instructions

3-90-775

X
X

X

X
X
X
X
X
X
X
X
X
X
Pellets or Corn/Pellet Mixture Only

29

P35i Fireplace Insert

C. General Maintenance Procedures
1. Burn Pot Grate Cleaning
•	 Frequency: Daily to Weekly *
•	 By: User
Wear Leather Gloves To Prevent Skin Burns!
This procedure can be done with a fire burning. It is
recommended that you turn the temperature dial down
approximately one half hour before to allow some
cooling of the fire.
Open the front door by lifting upward on the latch
handle, then swing the door open. Using the scraper
tool provided with your appliance, scrape any
cool or spent ashes from in front of the fire off
the front of the grate to the ash pan. Next,
scrape downward into the burn pot,
under the burning fuel to remove any
carbon deposits. Pay particular
attention to the corners on each
side of the auger, as this is
generally the first place to
see accumulation. You do
not want to scrape the fire
out of the pot, you just
want to clean the holed
surface underneath the
fire. Any loosened material will be pushed off of
the grate into the ash
pan as burning resumes. Close the door when finished, and return your temperature dial to the desired
setting.
* Depending on fuel quality and the quantity of fuel
consumed, the interval between scraping will vary. If
you see orange and lazy flames, it is a good indicator
of the need for scraping.
2. Ash Removal From Firebox
•	 Frequency: Weekly / depending on fuel and/or
ash buildup.
•	 By: User
Wear Gloves To Perform
The fire MUST be out and cool for safe ash removal.
The scraper tool can be used to knock any ash accumulation into the ash pan.
Frequent cleaning of ash from the firebox will help to
slow the accumulation of ash in the exhaust and venting system.
30 Pellets or Corn/Pellet Mixture Only

3-90-775

3. Emptying the Ash Pan
•	 Frequency: Bi-Weekly / as needed
•	 By: User
Wear Gloves To Perform
The fire MUST be out and cool for safe ash removal.
a. Remove the ash pan cover by grasping the ash lip
and slide forward.
b. Open the lower spring latch on each side to release
the ash pan.
c. Slide the ash pan straight out.
d. Empty into a
non-combustible
container and
slide the ash pan
straight into the
stove.
e. Secure the ash
pan by hooking
and closing the
spring latches.
4. Disposal of Ashes
•	 Frequency: As needed
•	 By: User
Ashes must be placed in a metal container with
a tight fitting lid. The closed container of ashes
should be placed on a non-combustible floor or
on the ground, well away from all combustible
materials, pending final disposal. If the ashes are
disposed of by burial in soil or otherwise locally
dispersed, they should be retained in the closed
container until all cinders have thoroughly cooled.
Do not use the ash container for other debris or
yard waste.

Save These Instructions

P35i Fireplace Insert

WARNING! RISK OF FIRE! Keep combustible materials, gasoline and other flammable vapors and liquids
clear of the appliance.
•	

Do NOT store flammable materials in the vicinity
of the appliance.

•	

Do NOT use gasoline, lantern fuel, kerosene,
charcoal lighter fluid or similar liquids to start or
"freshen up" a fire in this appliance.

Keep all such liquids well away from the heater while
it is in use, as combustible materials may ignite.
WARNING! RISK OF FIRE!
Do NOT store fuel:
•	 Within the required clearance areas of the appliance.
•	 Within the space required for fueling or ash removal.

a. Make sure the fire is out and cool. Disconnect
power cord prior to servicing.

Lift the cover off of the
wingscrews.

a. Loosen the two wingscrews located on the front of
the burn pot housing.
b. Lift the cover off of the wingscrews and set aside.
c. Using your ash-vac, remove any ashes or debris from
the air chamber.
d. You can tap on the igniter, located above the cleanout
hole. This will help to remove any accumulation on
the igniter element.
e. Re-install the cleanout cover and tighten the
wingscrews. Be sure that the cover is completely
covering the hole, as air leakage here may lead to
incomplete combustion or poor ignition.

Save These Instructions

NOTICE: For optimal performance of your pellet burning appliance, you must perform regular cleaning and
maintenance as directed in this manual. Not doing so
will result in:
	
Poor performance
	
Smoke spillage into the room
	
Overheating of components
Failure to perform regular cleaning on your pellet
burning appliance will void the warranty.

5. Cleaning Area Beneath Burn Pot Grate
•	 Frequency: Monthly or more frequently depending on fuel quality and/or ash buildup.
•	 By: User

Loosen the two wingscrews
on the front of the burn pot.

5. Cleaning Heat Exchanger & Exhaust
•	 Frequency: Monthly or after each ton of fuel is
burned.
•	 By: User
It is recommended that you use a vacuum that is
designed for ash, as ashes may block conventional
vacuum filters.

b. Scrape the majority of ashes into the ash pan. Begin with the back and roof above the burn pot.
c. Scrape the ashes from both sides, into the ash pan.

3-90-775

Pellets or Corn/Pellet Mixture Only

31

P35i Fireplace Insert

d. Un-latch and remove the ash pan. Dispose of the
ashes in a metal container with a tight fitting lid.

k. With this cover removed, you can vacuum the

e. Remove the two (2) corner cleanout covers by removing the wing-screws (one per).

paddle fan and the inside of the chamber. Be careful
not to bend the blades on the paddle fan.
f. Brush or vacuum the remaining ash from the firebox.

l. Before reinstalling the access cover, make sure the

g. Guide the vacuum hose upward into the exhaust
passage in the right rear corner of the firebox.

insulation between the two layers is in tact.

Vacuum or brush exhaust passage

h. You can now return all pieces inside the firebox and
close the door.
i. Release the spring latches and slide the insert body
out onto the hearth or onto the service rail kit, if purchased.
j. Remove the exhaust chamber access cover on the
right rear of the insert.

32 Pellets or Corn/Pellet Mixture Only

3-90-775

6. Inspect / Clean Hopper
•	 Frequency: Whenever run to empty
•	 By: User
Whenever the hopper is empty, inspect and remove
any large amounts of sawdust or fines. Although this
finer material will mostly feed through with the fuel,
large quantities of sawdust may restrict feeder flow.

Save These Instructions

P35i Fireplace Insert

7. Cleaning the Door Glass
•	 Frequency: As needed / Weekly
•	 By: User

8. Venting and Chimney System
•	 Frequency: Yearly or more frequently depending
on ash build-up.
•	 By: Service Technician / Chimney Sweep

Whenever the view of the fire is obstructed, or weekly,
clean the glass using a soft cloth dampened with standard household glass cleaner.
Never spray glass cleaner directly onto hot glass.
Apply the cleaner to the cloth then wipe the glass.
Inspect the glass and sealing gasket. Replace gasket
as needed. Do not operate the stove with a broken
glass. Replacement glass, which is ceramic glass,
should be obtained through your Harman dealer.
To replace a broken glass; first be sure to carefully
remove the broken glass and any remaining shards or
pieces. With the door laying on a flat surface, lay the
gasketted glass panel onto the door and be sure it is
properly fitted into the channel. Lay the glass retainer
clips in place near each corner, and secure them
using the 3/8" screws. Be sure to tighten each screw
equally so you don't create a pressure point on the
glass.
NEVER OPERATE THIS APPLIANCE WITH THE
GLASS DOOR REMOVED, CRACKED, BROKEN,
OR SCRATCHED.

Soot and Fly Ash: Formation & Need for Removal
The products of combustion will contain small
particles of fly ash. The fly ash will collect in the
exhaust venting system and restrict the flow of
exhaust gases.
During periods of incomplete combustion, which may
occur during start-up, shut down, or when operated
incorrectly, the fly ash may actually lead to soot
formation in the venting system.
The venting system will need to be cleaned at least
once per year, or more often depending on the quality
of the fuel being used. Horizontal sections of vent
pipe are especially prone to soot formation, as ash will
accumulate more quickly.
The chimney and venting system should be
inspected periodically throughout the heating
season to determine if a creosote buildup has
occurred. If a significant layer of creosote has
accumulated (3mm or more) it should be removed
to reduce the risk of a chimney fire.

Retainers and screws

Glass
Adhesive gasket
Door Frame

CAUTION
Handle glass with care.
When cleaning door glass;
•	 Avoid striking, scratching, or slamming glass.
•	 Do NOT Clean Glass When Hot.
•	 Do NOT use abrasive cleaners.
•	 Inspect gasket, replace if necessary.
Save These Instructions

3-90-775

Pellets or Corn/Pellet Mixture Only

33

P35i Fireplace Insert

D. Motors and Components

Hopper Lid Latch

Viewing
Glass

Ash Pan Cover
Door Latch
Return Air Slots

Control Panel

Combustion
Blower

Exhaust
Sensing
Probe (ESP)

Pellet Pro Feeder

Feed Motor

Distribution Blower
34 Pellets or Corn/Pellet Mixture Only

3-90-775

Frame Latch

Ash Pan Latch
Save These Instructions

P35i Fireplace Insert

1. Feed Motor
Requires no lubrication.
Keep the motor windings free of dust. Can be wiped
clean or vacuumed.
To remove feed motor;
•	 Slide the insert body out of the mounting frame.
•	 Between the feed motor and the feeder body,
you'll see the cam block with a bearing that actuates the pusher arm.
•	 With a 7/16" wrench, loosen the hex-head bolt in
the end of the cam.
•	 With the bolt loosened, the feed motor and its
mounting bracket will pull straight out of the auger
shaft.

3. ESP- (Exhaust Sensing Probe)
Remove and wipe clean with a soft cloth and glass
cleaner or alcohol.
To remove the probe;
•	 Slide the insert body out of the mounting frame.
•	 The probe is installed on the side of the exhaust
chamber.
•	 With a 1/4" socket or driver, remove the screw that
attaches the probe.
•	 Pull the probe out of it's mounting hole.

Loosen bolt in end of
cam block

2. Combustion Blower
Requires no lubrication.
Keep the motor windings free of dust. Can be wiped
clean or vacuumed.
To remove combustion blower;
•	 Slide the insert body out of the mounting frame.
•	 Locate the combustion blower motor in the back
right corner.
•	 Loosen 3 wing screws and turn the blower and
mounting plate 1/4 turn.
•	 Lower the motor and paddle fan out of the blower
housing.

Save These Instructions

3-90-775

ESP location

Pellets or Corn/Pellet Mixture Only

35

P35i Fireplace Insert

4. Distribution Blower
Requires no lubrication.
Keep the motor windings and squirrel cage fan free of
dust. Can be wiped clean or vacuumed.
To remove distribution blower;
•	 Slide the insert body out of the mounting frame.
•	 Locate the blower in the back of the unit. You'll
need to tilt the unit forward for easy access.
•	 Remove 8 tek screws using a 5/16" driver or
wrench.

Loosen wing nut to remove cover

8 screws

5. Feeder Body
Vacuum fines from this area

Wipe or vacuum to clean.
Use a vacuum to remove fines and sawdust.
To access feeder cleanout;
•	 Slide the insert body out of the mounting frame.
•	 Locate the feeder cover from the right side of the
unit.
•	 Loosen the wing nut approximately 3/4 of the way
out on the stud.
•	 Pull out on the bottom of the cover then lift upward
to remove.
•	 Notice the deflector shield is sitting loose in the
feeder. It can be removed by rolling it from under
the pusher arm shaft. Just be sure it is repositioned properly.
•	 When re-installing cover, tighten the wing nut hand
tight only.
36 Pellets or Corn/Pellet Mixture Only

3-90-775

Save These Instructions

P35i Fireplace Insert

6. Igniter
Vacuum to clean.
Whenever cleaning burn pot air chamber.
To remove igniter;
•	 Loosen wing screws and remove cover on front of
burn pot.
•	 Using a 5/16" wrench, remove the two black
screws above the cleanout. The igniter and bracket are now free.
•	 Slide the insert body out of the mounting frame.
•	 Locate the pale blue and yellow wires entering at
the bottom of the feeder body.
•	 Remove wire ties as needed to loosen the igniter
wires.
•	 Pull the igniter and bracket out from the front until
the wire disconnects are accessible.
•	 When installing igniter, reverse these steps and be
sure that the plastic coated wires are pulled all the
way to the rear of the feeder.
•	 Re- tie all wires clear of all hot or moving parts.

FEED MOTOR

This hole in the feeder body is where the igniter wires
pass through to the burn pot.

This shows the igniter and bracket removed from the
burn pot. Missing in the illustration is the wires from the
igniter which run through the burn pot air chamber. Only
the first few inches of the wires are insulated for high
temperatures. These insulated wires are all that can be
inside the feeder or burn pot.

Save These Instructions

3-90-775

Pellets or Corn/Pellet Mixture Only

37

3-90-775

D

R COR

DK BLUE or BLACK

DK BLUE

WHITE

GREEN

DISTRIBUTION BLOWER

N.O. CONTACTS

LOW PRESSURE SWITCH

WHITE

BROWN

OUTBOARD
FEEDER MOTOR
ACC/XXV

BLACK

ESP
CONTROL
BOARD

IGNITER ELEMENT
INSIDE BURNPOT

STANDARD
FEEDER MOTOR
P35I

MALE/FEMALE CONNECTIONS

LT.BLUE

N.O. CONTACTS

HOPPER LID SWITCH
3-20-232108

REMOTE SENSOR PORTS
ACC/XXV

MAX WATTS - 440 @ 120VAC 60Hz = 3.6 A
STANDARD USE WATTS - 180 @ 120VAC 60Hz = 1.5 A

COMBUSTION MOTOR

WHITE

MALE/FEMALE CONNECTIONS

MALE/FEMALE CONNECTIONS

BONDED TO STOVE FRAME

GREEN WIRE IS GROUND

POWE

CORD

YELLOW

HARMAN - ACCENTRA, XXV, P35I PELLET STOVE WIRING DIAGRAM

RED

18/3 R
UBBER

1

2

WHITE
LT.BLUE

38 Pellets or Corn/Pellet Mixture Only
1

10
11
BLACK

PART NO. 3-90-00777C

9
RED

8
BLUE

7
YELLOW

6
EMPTY

5

4
WHITE

3
WHITE
WHITE

2
WHITE

1

ESP PROBE

PLUGGED

BROWN

11

8
9
10

3
4
5
6

6 AMP GLASS FUSE

ROOM SENSOR TERM.
P35I

WHITE 11 PIN PLUG

11
P35i Fireplace Insert

Reference Materials

Save These Instructions

GREEN USED ON ACCENTRA ONLY

WHITE or LT BLUE

P35i Fireplace Insert

Addendum
Minimizing Smoke During Loss of Power Using Battery Back-up
HarmanTM strongly recommends installing battery back-up to minimize entry of smoke into the
room in the event of power loss.
Your pellet/biomass burning appliance relies on a combustion blower to remove exhaust. A power failure
will cause the combustion blower to stop. This may lead to exhaust seeping into the room. Vertical rise in
the venting may provide natural draft. It is, however, no guarantee against leakage.
There are two HarmanTM approved battery back-up options for your appliance:
Uninterruptible Power Supply (UPS) UPS battery back-ups are available online or at computer and
TM
office equipment stores. Your Harman appliance with Rev E or later software available beginning in
TM
November 2010 may be plugged directly into a Harman approved UPS:
•

The APC (American Power Conversion) model #BE750G and the TrippLite model
INTERNET750U are tested and approved. Other brands or models may not be compatible.

When power is lost, a fully charged UPS will power a safe, combustion blower only shut-down. Your
appliance will pulse the blower every few seconds to clear exhaust until the fire is out. NOTE: The UPS
provides safe shut-down only. It is not intended for continued operation.
Your appliance will recognize when power is restored. What happens depends on ESP temperature and
whether it is equipped with automatic ignition:
• In “Automatic” setting, units equipped with automatic ignition will respond to the set point and
ESP temperature and resume normal operation.
• In “Manual” setting or for units without automatic ignition:
• If the ESP is cool, the appliance will remain shut down.
• If the fire is out and the ESP is still warm, the feeder may restart. Since the fire is out, the
ESP temperature will not rise. The unit will then shut-down, and may flash a six-blink status
error. (See ESP error codes)
• If the fire is still burning, it will resume normal operation.
Contact your dealer if you have questions about UPS compatibility with your appliance.
Harman Surefire 512H Battery Back-up The 512H connects to a 12 volt deep cycle battery that will run
your appliance for up to eight (8) hours. It includes a trickle charge feature that keeps your battery
charged when power is available. NOTE: If the power is out for longer than battery life, smoke
leakage may still occur unless your stove has been safely shut down.

CAUTION! Always keep appliance doors and hopper lid closed and latched during
operation and during power failures to minimize risk of smoke or burn-back.
CAUTION! Use only HarmanTM approved battery back-up devices. Other products may not
operate properly, can create unsafe conditions or damage your appliance.

Save These Instructions

3-90-775

Pellets or Corn/Pellet Mixture Only

39

P35i Pellet Insert

Service Parts

Beginning Manufacturing Date: July 2010
Ending Manufacturing Date: Active

Pellet Insert

(23.5 in)1-70-774235-1 (Black), (19.5 in)1-70-774195-1 (Black),
Ending Manufacturing Date: June 2011
(23.5 in) 1-70-774235-2 (Charcoal), 1-70-774235-3 (Goldenfire))
(19.5 in) 1-70-774195-2 (Charcoal), 1-70-774195-3 (Goldenfire))

3

4

9

1
2

10
11
12

13

7
8

5
6

14
26

25

15
16
17

27

19

22 23

20

24

21

18

Part number list on following page.
08/11

P35i Pellet Insert

Service Parts

Beginning Manufacturing Date: July 2010
Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
ITEM

Description

1

Pipe Stub/4 in Flex w/gasket

2

Gasket Set, Burnpot/Pipe Stub

3

Mounting Frame Assembly

COMMENTS

Stocked
at Depot
PART NUMBER
1-00-674040

Set of 5

1-00-07384

Y

1-10-774235A
4.1

#4 Surround Assembly
4.3

4.2

4.4

4.5
4.6

4.7

Oversize-Black

4

Wing Assembly

1-00-774250-1

No longer available

1-00-774250-2

No longer available

1-00-774250-3

Custom

1-00-774221-SPL

Standard

1-10-774222

Oversize

1-10-774250

4.1

Surround Top

4.2

Machine Screw Nut10-32

Pkg of 100

3-30-8003-100

4.3

Pop Rivet 1/8 X 1/8 Black

Pkg of 50

3-30-9004-50

4.4

Surround Left

Standard

1-10-774220

Oversize

1-10-774248

4.5

Control Door w/Hinge

4.6

Screw, PHM 8 X 1/2 Black

4.7

Surround Right

Y

1-00-774310
Pkg of 100

3-30-5000-100

Standard

1-10-774221

Oversize

1-10-774249

Y

5

Differential Switch

3-20-6866

Y

6

Docking Gasket

3-44-06108

Y

7

4 Output Circuit Board w/Knobs & Shafts

1-00-05886

Y

8

Circuit Board Plate

1-10-774114A

Y

9

Black Knob

3-43-02000-1

Additional service parts on following page.
08/11

P35i Pellet Insert

Service Parts

Beginning Manufacturing Date: July 2010
Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
ITEM

Description

10

Top Assembly

11

Hopper Latch
23.5 in Hopper

12
19.5 Iin Hopper

COMMENTS

3/8X1/2 Silicone PSA-20FT For hopper top

14

Spring Latch

15

Ash Pan W/Gasket

1-10-774223A

Y

1-00-0669697

Y

Pre 008651553

1-10-774050A

Y

Post 008651553

1-10-774150A

Y

Pre 008651553

1-10-774028A

Y

Post 008651553

1-10-774128A

Y

3-20-232108

Y

1-00-375501

Y

3-31-00927

Y

1-10-774207

Y

3-44-774211

Y

Qty 4 req

Ash Pan Gasket
16

Ash Pan Cover Assembly

17

Load Door

1-10-774205A
Painted Only

Door glass
1/4 Rd Black PSA For glass

15 Ft Length

Glass Clips & Hdwr
Latch Kit
Cast Front Door Latch
3/8 4 Strand White-30 Ft
18

PART NUMBER

2 Sets

Switch, Hopper Lid,48 in
13

Stocked
at Depot

30 Ft Length

Wood Handle w/Bolt

4-00-06800P
3-40-00774

Y

1-00-2312

Y

1-00-249140

Y

1-00-73553

Y

3-00-249119

Y

1-00-00888

Y

1-00-00247

Y

19

Burnpot w/Cleanout

1-10-774286

Y

20

Flame Guide

3-00-03000

Y

21

Cleanout Cover Set

22

Combustion Blower

3-21-08639

23

Combustion Blower Mount

1-10-677006

24

4-3/4 Single Paddle Blade

3-21-00661

Y

25

Combustion Cleanout

1-10-774167A

Y

26

Distribution Blower

3-21-29045

Y

27

UL Feeder Assembly

Left & Right

1-00-774213
Y

See following page

14 Ft Power cord

3-20-674200

Y

306W/120V Igniter 15 Fin

3-20-677200

Y

ESP-RED/RED

3-20-00844

Y

Pipe Insulation

3-44-774282

Y

1-00-05232

Y

3-20-00906

Y

Roller Hardware

4 Sets

Room Sensor
Touch up Paint, Black
Wiring Harness

12 oz Can

3-42-1990
3-20-08727

Y

Additional service parts on following page.
08/11

P35i Pellet Insert

Service Parts

Beginning Manufacturing Date: July 2010
Ending Manufacturing Date: Active

#27 Feeder Assembly
27.10

27.9

27.1

27.6

27.8

27.3

27.7

27.2

27.4
27.5
27.20
27.19
27.18

27.11
27.17

27.13
27.12

27.16

27.14

27.15

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
ITEM
27

Description

COMMENTS

Stocked
at Depot
PART NUMBER

UL Feeder Assembly

1-10-774000A

Y

27.1

Pellet Feeder CW Motor-4 RPM

3-20-60906

Y

27.2

Feeder Motor Bracket w/ Grommet

1-00-247406

Y

27.3

Bearing 3/8 ID X 1-1/8 OD
Cast Cam Block

3-31-3014

Y

3-00-677154

Y

27.4

Pellet Feeder Bearing RETNR w/Bolts

1-00-04035

Y

27.5

Pellet Feeder Auger

3-50-00565

Y

27.6

Feeder Air Crossover Kit

1-00-67900

Y

5 Ft Length

1-00-511427

Y

9MM X 13MM Tubing Kit
27.7

1/8 Silicone Tubing

5 Ft Length

1-00-5113574

Y

27.8

Screws-HWH TEKS 10 X 3/4

Pkg of 100

3-30-5004-100

Y

27.9

Pellet Air Intake w/Gasket

1-10-06810A
Pkg of 6

3-44-72224-6

Y

27.10

Gasket, Feeder Air Intake

27.11

Snout Weldment w/Gasket

1-10-774143A

27.12

Pellet Feeder Weldment

1-10-724132

Y

27.13

Flange 1/4-20 X 3/8

Pkg of 50

3-30-2000-50

Y

27.14

Pillow Block-1/2 in

Pkg of 4

3-31-3614087-4

Y

27.15

Wing Nut, 5/16-18

Pkg of 25

3-30-8012-25

Y

27.16

Short Feed CVR & Gasket

1-00-677122

Y

27.17

Pusher Arm Assembly

1-10-774354W

Y

27.18

Slide Plate

1-10-677121A

Y

27.19

Nut, FHN 5/16-18 Z 5

Pkg of 100

3-30-8005-100

Y

27.20

Grommet-1/2 in ID-Thick

Pkg of 12

3-31-2761-12

Gasket Hopper Throat

3-44-677185

Y
08/11

P35i Fireplace Insert

D. Custom Size Surround

This diagram shows the minimum dimensions of a custom fit surround panel, part number
1-00-774221-SPL. Note that arched surrounds can only be made flat. Therefore, the intake air
slots, normally in the sides of the surround, are moved to the face. Rectangular surrounds can
be made flat if desired, and they will also have the intake slots in the face.

P35i Custom Surround Part #: 1-00-774221-SPL
The top of the mounting frame
must be covered at this point.

RectangularMinimum Height
28 11/16"
729 mm

Arched- Minimum
Center Height
31 3/8"
797 mm

Arched- Minimum
Side Height
24 7/8"
632 mm

Minimum
Width- 40"
1016mm

44 Pellets or Corn/Pellet Mixture Only

3-90-775

Save These Instructions

Hearth & Home Technologies Inc.
LIMITED LIFETIME WARRANTY
Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for
HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.
WARRANTY COVERAGE:

HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership
of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance
will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered components manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period,
HHT will, at its option, repair or replace the covered components. HHT, at its own discretion, may fully discharge all of its
obligations under such warranties by replacing the product itself or refunding the verified purchase price of the product
itself. The maximum amount recoverable under this warranty is limited to the purchase price of the product. This warranty
is subject to conditions, exclusions and limitations as described below.

WARRANTY PERIOD:

Warranty coverage begins on the date of original purchase. In the case of new home construction, warranty coverage
begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent,
authorized HHT dealer/ distributor, whichever occurs earlier. The warranty shall commence no later than 24 months
following the date of product shipment from HHT, regardless of the installation or occupancy date. The warranty period for
parts and labor for covered components is produced in the following table.
The term “Limited Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage for
gas appliances, and 10 years from the beginning date of warranty coverage for wood, pellet, and coal appliances. These
time periods reflect the minimum expected useful lives of the designated components under normal operating conditions.

Warranty Period
Parts

Labor

1 Year

2 years

HHT Manufactured Appliances and Venting
Gas

X

X

Wood

X

X
X

3 years

Pellet

EPA
Wood

Coal

X

X

X

X

X

X

X

X

X

Components Covered

Electric Venting

X

X

All parts and material except as
covered by Conditions,
Exclusions, and Limitations
listed
Igniters, electronic components,
and glass
Factory-installed blowers
Molded refractory panels

X

Firepots and burnpots

5 years

1 year

7 years

3 years

10
years

1 year

X

Limited
3 years
Lifetime

X

X

X

X

X

90 Days

X

X

X

X

X

X

X

X

Castings and baffles

X

X

Manifold tubes,
HHT chimney and termination
Burners, logs and refractory
Firebox and heat exchanger
X

X

All replacement parts
beyond warranty period

See conditions, exclusions, and limitations on next page.
4021-645C 12-29-10

Page 1 of 2

WARRANTY CONDITIONS:
•
•
•
•

This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of
HHT authorized dealers is available on the HHT branded websites.
This warranty is only valid while the HHT appliance remains at the site of original installation.
Contact your installing dealer for warranty service. If the installing dealer is unable to provide necessary parts, contact
the nearest HHT authorized dealer or supplier. Additional service fees may apply if you are seeking warranty service
from a dealer other than the dealer from whom you originally purchased the product.
Check with your dealer in advance for any costs to you when arranging a warranty call. Travel and shipping charges
for parts are not covered by this warranty.

WARRANTY EXCLUSIONS:

This warranty does not cover the following:
• Changes in surface finishes as a result of normal use. As a heating appliance, some changes in color of interior and
exterior surface finishes may occur. This is not a flaw and is not covered under warranty.
• Damage to printed, plated, or enameled surfaces caused by fingerprints, accidents, misuse, scratches, melted items,
or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes.
• Repair or replacement of parts that are subject to normal wear and tear during the warranty period. These parts
include: paint, wood, pellet and coal gaskets, firebricks, grates, flame guides, light bulbs, batteries and the discoloration of glass.
• Minor expansion, contraction, or movement of certain parts causing noise. These conditions are normal and complaints related to this noise are not covered by this warranty.
• Damages resulting from: (1) failure to install, operate, or maintain the appliance in accordance with the installation
instructions, operating instructions, and listing agent identification label furnished with the appliance; (2) failure to
install the appliance in accordance with local building codes; (3) shipping or improper handling; (4) improper operation, abuse, misuse, continued operation with damaged, corroded or failed components, accident, or improperly/
incorrectly performed repairs; (5) environmental conditions, inadequate ventilation, negative pressure, or drafting
caused by tightly sealed constructions, insufficient make-up air supply, or handling devices such as exhaust fans or
forced air furnaces or other such causes; (6) use of fuels other than those specified in the operating instructions; (7)
installation or use of components not supplied with the appliance or any other components not expressly authorized
and approved by HHT; (8) modification of the appliance not expressly authorized and approved by HHT in writing;
and/or (9) interruptions or fluctuations of electrical power supply to the appliance.
• Non-HHT venting components, hearth components or other accessories used in conjunction with the appliance.
• Any part of a pre-existing fireplace system in which an insert or a decorative gas appliance is installed.
• HHT’s obligation under this warranty does not extend to the appliance’s capability to heat the desired space. Information is provided to assist the consumer and the dealer in selecting the proper appliance for the application. Consideration must be given to appliance location and configuration, environmental conditions, insulation and air tightness of
the structure.

This warranty is void if:
•
•
•

The appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluorine, or other damaging
chemicals. Over-firing can be identified by, but not limited to, warped plates or tubes, rust colored cast iron, bubbling,
cracking and discoloration of steel or enamel finishes.
The appliance is subjected to prolonged periods of dampness or condensation.
There is any damage to the appliance or other components due to water or weather damage which is the result of, but
not limited to, improper chimney or venting installation.

LIMITATIONS OF LIABILITY:
•

The owner’s exclusive remedy and HHT’s sole obligation under this warranty, under any other warranty, express or
implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above. In no
event will HHT be liable for any incidental or consequential damages caused by defects in the appliance. Some states
do not allow exclusions or limitation of incidental or consequential damages, so these limitations may not apply to you.
This warranty gives you specific rights; you may also have other rights, which vary from state to state. EXCEPT TO
THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY
SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE
EXPRESSED WARRANTY SPECIFIED ABOVE.

4021-645C 12-29-10

Page 2 of 2

P35i Fireplace Insert

Service & Maintenance Log
Date Of Service

Performed By

Save These Instructions

Description Of Service

3-90-775

Pellets or Corn/Pellet Mixture Only

47

Proudly Printed On 100% Recycled Paper



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Create Date                     : 2011:08:22 09:26:45-04:00
Creator                         : Adobe InDesign CS4 (6.0.6)
Modify Date                     : 2011:08:30 07:01:02-05:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Instance ID                     : uuid:366468d3-0df2-49b0-ad22-0ef73505ce4d
Document ID                     : xmp.did:D8D93EA2B3CCE011AE9FF798EEE28576
Original Document ID            : adobe:docid:indd:9f465667-ec13-11df-9a8f-820c51d8ab3d
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:D7D93EA2B3CCE011AE9FF798EEE28576
Derived From Document ID        : xmp.did:035231C61039E011A4449CF81DCD8DC7
Derived From Original Document ID: adobe:docid:indd:9f465667-ec13-11df-9a8f-820c51d8ab3d
Derived From Rendition Class    : default
History Action                  : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:6C832A7044F6DF119467C9E5E431D3E7, xmp.iid:6D832A7044F6DF119467C9E5E431D3E7, xmp.iid:044B950E45F6DF11BBECCDD2ED29AF66, xmp.iid:054B950E45F6DF11BBECCDD2ED29AF66, xmp.iid:025231C61039E011A4449CF81DCD8DC7, xmp.iid:035231C61039E011A4449CF81DCD8DC7, xmp.iid:045231C61039E011A4449CF81DCD8DC7, xmp.iid:4434D5F44139E011A4449CF81DCD8DC7, xmp.iid:5DCC6C56C73DE0118E83C1A67E996158, xmp.iid:5ECC6C56C73DE0118E83C1A67E996158, xmp.iid:D7D93EA2B3CCE011AE9FF798EEE28576, xmp.iid:D8D93EA2B3CCE011AE9FF798EEE28576, xmp.iid:D9D93EA2B3CCE011AE9FF798EEE28576, xmp.iid:DAD93EA2B3CCE011AE9FF798EEE28576, xmp.iid:DBD93EA2B3CCE011AE9FF798EEE28576, xmp.iid:DCD93EA2B3CCE011AE9FF798EEE28576
History When                    : 2010:11:22 09:26:04-05:00, 2010:11:22 09:26:04-05:00, 2010:11:22 09:30:30-05:00, 2010:11:22 09:33:11-05:00, 2011:02:15 14:43:23-05:00, 2011:02:15 14:43:24-05:00, 2011:02:15 15:20:57-05:00, 2011:02:15 15:27:06-05:00, 2011:02:21 11:22:41-05:00, 2011:02:21 11:25:27-05:00, 2011:08:22 07:41:11-04:00, 2011:08:22 07:41:11-04:00, 2011:08:22 07:58:37-04:00, 2011:08:22 08:03:55-04:00, 2011:08:22 08:15:37-04:00, 2011:08:22 08:33:14-04:00
History Software Agent          : Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0
History Changed                 : /, /metadata, /, /, /metadata, /;/metadata, /, /, /, /, /metadata, /;/metadata, /, /, /, /
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 300.00, 200.00, 72.00, 144.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 72.00, 300.00, 300.00, 72.00, 72.00, 72.00, 300.00, 72.00, 72.00, 72.00, 300.00, 72.00, 72.00, 300.00, 72.00, 300.00, 300.00, 300.00, 72.00, 300.00, 72.00, 72.00, 300.00, 72.00, 300.00, 200.00, 200.00, 72.00, 300.00, 150.00, 200.00, 200.00, 300.00, 72.00, 72.00, 300.00, 72.00, 200.00, 300.00, 72.00, 200.00, 300.00, 150.00, 72.00, 150.00, 200.00, 300.00, 300.00, 300.00, 150.00, 300.00, 300.00, 300.00, 200.00, 300.00, 72.00, 300.00, 300.00, 300.00, 400.00, 150.00, 300.00, 300.00, 200.00, 200.00, 300.00, 300.00, 300.00, 200.00, 200.00, 200.00, 200.00, 300.00, 72.00, 300.00, 72.00, 72.00, 300.00, 200.00, 200.00, 150.00, 300.00, 200.00, 200.00, 200.00, 300.00, 200.00, 200.00, 300.00, 72.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 300.00, 72.00, 72.00, 72.00, 300.00, 72.00
Manifest Placed Y Resolution    : 300.00, 200.00, 72.00, 144.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 72.00, 300.00, 300.00, 72.00, 72.00, 72.00, 300.00, 72.00, 72.00, 72.00, 300.00, 72.00, 72.00, 300.00, 72.00, 300.00, 300.00, 300.00, 72.00, 300.00, 72.00, 72.00, 300.00, 72.00, 300.00, 200.00, 200.00, 72.00, 300.00, 150.00, 200.00, 200.00, 300.00, 72.00, 72.00, 300.00, 72.00, 200.00, 300.00, 72.00, 200.00, 300.00, 150.00, 72.00, 150.00, 200.00, 300.00, 300.00, 300.00, 150.00, 300.00, 300.00, 300.00, 200.00, 300.00, 72.00, 300.00, 300.00, 300.00, 400.00, 150.00, 300.00, 300.00, 200.00, 200.00, 300.00, 300.00, 300.00, 200.00, 200.00, 200.00, 200.00, 300.00, 72.00, 300.00, 72.00, 72.00, 300.00, 200.00, 200.00, 150.00, 300.00, 200.00, 200.00, 200.00, 300.00, 200.00, 200.00, 300.00, 72.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 300.00, 72.00, 72.00, 72.00, 300.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:0C4860D4DF1BDF11A53899C7343443B2, uuid:1A11216CD346DE1189A1F23286615BD1, uuid:444A06887B26DC11847BD4B7051D64B4, uuid:02ed85f3-4e63-48a9-969d-a90df75202dd, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:b4a5b394-fa58-4d2f-856e-1334a32452c7, uuid:0cc65c5f-7d6c-42d3-81fb-376755492245, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:4f8f88f1-9171-4234-922a-ed1451a46453, uuid:c16f7936-86d2-46b4-88fa-ec1930bb8d75, uuid:0414e03b-0e8c-469d-8a78-0573d17913fe, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:eca99cff-8ebb-4359-b318-7288532fd314, uuid:ffce325a-1543-4fd4-9c55-1cbab4e77f0f, uuid:3d0530ff-c476-418a-a96b-af2c2b3f7a51, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:50FC72BA9E3EDC119301C4B3720E1DF3, uuid:a8a09885-234a-43b9-b550-e4973583e311, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:2dc38b7f-7ef5-448f-bf1c-4a1920e251ef, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:3b09aebe-3d9c-4512-8144-a367294bc7b5, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:7dfefeaa-0942-438c-a7bf-398208fa7637, uuid:b90a9199-b61f-49c5-bbb7-8d5d4f335eda, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:124e5798-4528-4669-ad39-2c50a4351492, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:EF2536CF4846DF11B4F7E2B575E23453, uuid:E94C79218157DF11AB6AC8614F551DAA, uuid:d436caf0-dd70-45cc-af26-ad40009bc2a7, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:28ED847DC44BDF11AC9AA671C2E2EA61, uuid:54642AD09553DF11A4FEDBA6C9612ED3, uuid:28D44C289C53DF11A4FEDBA6C9612ED3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:f5ca9f0a-62ba-421f-ae6b-9591b01d5b1a, uuid:80b330a5-8d7a-4072-a2f9-16c3f0e7a0c3, uuid:FE1219D03A67DF11AE20AF6B2A2367C8, uuid:a8fb414a-21a5-4cd0-9001-b082d09f3f56, uuid:30D44C289C53DF11A4FEDBA6C9612ED3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:b0b2a127-709f-4240-8a4e-592487df361a, uuid:F953791F5C49DF1181F2FBC6D0E35FFE, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:875831A2924CDF118660D8C7BAE7503F, uuid:357abf6a-e4b8-40d3-a89f-b76cb8d27cc0, uuid:FFA500369D4CDF119356E6A16FD036B5, uuid:E5342342C153DF11A4FEDBA6C9612ED3, uuid:004E82583F59DF1184B3BC781DA30582, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:91B9CB598653DF11A4FEDBA6C9612ED3, uuid:F08DF1C5E536DC11AFA68019C9DB08E3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:75705B4E8654DF11A134C8171493BE6F, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:81f84cdd-3eb2-44f7-9091-ba8cf6e4be8a, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:D09248B74839DC1181A2E2446235CC12, uuid:26F9CD535A51DF11A113A7E042F90878, uuid:D3578BFC1D52DF11804AA6484B391664, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:605D7D4F6151DF11B2A3D9DD5E702AF5, uuid:A23012156251DF11B2A3D9DD5E702AF5, uuid:3E30E9461E52DF11804AA6484B391664, uuid:D4B6609F1E52DF11804AA6484B391664, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:99B9CB598653DF11A4FEDBA6C9612ED3, uuid:95B9CB598653DF11A4FEDBA6C9612ED3, uuid:818676B68653DF11A4FEDBA6C9612ED3, uuid:7C8676B68653DF11A4FEDBA6C9612ED3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:fbe14743-9a56-4af9-9964-d0f0ea47e2ad, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:b4a5b394-fa58-4d2f-856e-1334a32452c7, uuid:0cc65c5f-7d6c-42d3-81fb-376755492245, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:6E7C09288453DF11A4FEDBA6C9612ED3, uuid:B45E9E26DD52DF11952CAE2B7FD312AB, uuid:91B9CB598653DF11A4FEDBA6C9612ED3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:6A7C09288453DF11A4FEDBA6C9612ED3, uuid:8A0B4DF38753DF11A4FEDBA6C9612ED3, uuid:894295B38853DF11A4FEDBA6C9612ED3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:914295B38853DF11A4FEDBA6C9612ED3, uuid:94C630DD8C53DF11A4FEDBA6C9612ED3, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:d30ac075-92c1-489e-ba6d-74a2bef1b742, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:2374d9d6-3ec1-4e51-84bc-82db32cb526d, uuid:b64e550e-3f36-4157-b736-63101a44b738, uuid:b64e550e-3f36-4157-b736-63101a44b738, uuid:b64e550e-3f36-4157-b736-63101a44b738, uuid:b64e550e-3f36-4157-b736-63101a44b738, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:b90fb50e-58f5-4f5a-9e2b-b4990001a1de, uuid:06a23f02-8c3d-4c98-8126-0bfea49e781f, uuid:4a73ba25-a906-4b3f-9213-140c9da6ade2, xmp.iid:2FF8E17CA37CE0118C79897AA7502EE3, uuid:40d4d8df-9ac7-46fd-ad6e-c7fb6e221c02
Manifest Reference Document ID  : xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:0BD21470DF1BDF11A53899C7343443B2, uuid:5752BC05D346DE119B11B97A970C93BB, uuid:434A06887B26DC11847BD4B7051D64B4, uuid:B554862E7D7BDE11B32DF85249149CF3, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:71B4C41EAA35DF11AE5A92B3448C6CF7, uuid:EC10E24BBE32DF11BD66806E84658FED, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:E810E24BBE32DF11BD66806E84658FED, uuid:EA10E24BBE32DF11BD66806E84658FED, uuid:E610E24BBE32DF11BD66806E84658FED, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:73B4C41EAA35DF11AE5A92B3448C6CF7, uuid:75B4C41EAA35DF11AE5A92B3448C6CF7, uuid:77B4C41EAA35DF11AE5A92B3448C6CF7, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:4FFC72BA9E3EDC119301C4B3720E1DF3, uuid:4878A4AED743DF11827BAF3FDC14741E, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:A0340A2D6786DD118E59F6DA33D6C2B7, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:B39593052443DF11AB97BE8EA9B48E3E, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:AB2161CFDF43DF11A844C5FE144FA26E, uuid:AD2161CFDF43DF11A844C5FE144FA26E, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:6191A1DC3346DF11BDA69B1D4B0D0A8A, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:0CE35FDA4746DF11B4F7E2B575E23453, uuid:E84C79218157DF11AB6AC8614F551DAA, uuid:0D21C6509057DF11A5D1CF62AF547906, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:27ED847DC44BDF11AC9AA671C2E2EA61, uuid:53642AD09553DF11A4FEDBA6C9612ED3, uuid:5B642AD09553DF11A4FEDBA6C9612ED3, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:E46E559EBD47DF11BFC0BEBA59BA3699, uuid:E66E559EBD47DF11BFC0BEBA59BA3699, uuid:11E1381D4D3CDC119457C2932D4A6013, uuid:F3BC5B1A5846DF1187FD885AC8E8E4A3, uuid:2FD44C289C53DF11A4FEDBA6C9612ED3, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:80EFDD1ACE64DF11BA81BE710DCD2859, uuid:F853791F5C49DF1181F2FBC6D0E35FFE, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:865831A2924CDF118660D8C7BAE7503F, uuid:8BAEC077E259DE11AAAFB98100A7FE7B, uuid:FEA500369D4CDF119356E6A16FD036B5, uuid:E4342342C153DF11A4FEDBA6C9612ED3, uuid:568FBC2C3F59DF1184B3BC781DA30582, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:0730D382584DDF119849E4175EB520B7, uuid:EF8DF1C5E536DC11AFA68019C9DB08E3, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:74705B4E8654DF11A134C8171493BE6F, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:A19AA3447D54DF11B5D0ECF65088CDE0, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:CF9248B74839DC1181A2E2446235CC12, uuid:25F9CD535A51DF11A113A7E042F90878, uuid:D2578BFC1D52DF11804AA6484B391664, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:5F5D7D4F6151DF11B2A3D9DD5E702AF5, uuid:675D7D4F6151DF11B2A3D9DD5E702AF5, uuid:3D30E9461E52DF11804AA6484B391664, uuid:4530E9461E52DF11804AA6484B391664, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:898403F72D52DF11A6B79CC21CE45FDE, uuid:B140E70A2D52DF11A6B79CC21CE45FDE, uuid:9B103201C552DF11952CAE2B7FD312AB, uuid:669C5626BB52DF11952CAE2B7FD312AB, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:66B160E4345FDE1198DFC393BF5B70DC, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:71B4C41EAA35DF11AE5A92B3448C6CF7, uuid:EC10E24BBE32DF11BD66806E84658FED, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:A3103201C552DF11952CAE2B7FD312AB, uuid:B35E9E26DD52DF11952CAE2B7FD312AB, uuid:0730D382584DDF119849E4175EB520B7, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:697C09288453DF11A4FEDBA6C9612ED3, uuid:890B4DF38753DF11A4FEDBA6C9612ED3, uuid:910B4DF38753DF11A4FEDBA6C9612ED3, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:904295B38853DF11A4FEDBA6C9612ED3, uuid:93C630DD8C53DF11A4FEDBA6C9612ED3, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:373069528D41DF118552F6C19C948162, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:2754950b-baea-4362-b3de-83f81b0953b5, uuid:1d42a7b9-f672-4108-b64c-cfe16767e83e, uuid:1d42a7b9-f672-4108-b64c-cfe16767e83e, uuid:1d42a7b9-f672-4108-b64c-cfe16767e83e, uuid:1d42a7b9-f672-4108-b64c-cfe16767e83e, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:38D2F2DC8E5FDF119780C890E01ACD9D, xmp.did:C1857719CB18E01192B49159F6005108, xmp.did:BF0776F3CA18E011948FF3D7FD5E79FA, xmp.did:2FF8E17CA37CE0118C79897AA7502EE3, uuid:A8C049117EC2DF118571F67E506CF10B
Metadata Date                   : 2011:08:30 07:01:02-05:00
Creator Tool                    : Adobe InDesign CS4 (6.0.6)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 13396 bytes, use -b option to extract)
Doc Change Count                : 332
Format                          : application/pdf
Producer                        : Adobe PDF Library 9.0
Trapped                         : False
Page Count                      : 48
EXIF Metadata provided by EXIF.tools

Navigation menu