Harman Tl 2 0 Owner S Manual
2014-07-05
: Harman Harman-Tl-2-0-Owner-S-Manual harman-tl-2-0-owner-s-manual harman pdf
Open the PDF directly: View PDF .
Page Count: 40
Download | |
Open PDF In Browser | View PDF |
Wood Stove Use & Care Video Owner's Manual Installation and Operation Model: TL2.0 Non-Catalytic, Top Load, Wood Burning Room Heater Item #1-90-856000 Contact your local dealer with questions on installation, operation or service. NOTICE DO NOT DISCARD THIS MANUAL • Important operating and maintenance instructions included. ! • Read, understand and follow these instructions for safe installation and operation. Do N ot Disca rd WARNING HOT SURFACES! Gl a s s a n d other s u r fa ce s a re hot during operation AND cool down. • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. • Do not overfire - If any external part starts to glow, you are overfiring. Close air controls. Overfiring will void your warranty. • Comply with all minimum clearances to combustibles as specified. Failure to comply may cause a house fire. Hot, will cause burns. • Do not touch glass until it is cooled • NEVER allow children to touch glass • Keep children away • CAREFULLY SUPERVISE children in same room as fireplace. • Alert children and adults to hazards of high temperatures. High temperatures may ignite clothing or other flammable materials. • Keep clothing, furniture, draperies and other flammable materials away. ! CAUTION Tested and approved for use with dry, seasoned cordwood only. Do Not Burn Wet or Green Wood. Burning any other type of fuel will void your warranty. Save These Instructions party responsible for use and operation. ! WARNING Please read this entire manual before installation and use of this wood-burning room heater. F a il u re to f ollow the s e instructions could result in property damage, bodily injury or even death. ! • Leave this manual with CAUTION Check building codes prior to installation. • Installation MUST comply with local, regional, state and national codes and regulations. • Consult local building, fire officials or a u thoritie s h av in g j u ri s d iction a bo u t restrictions, installation inspection, and permits. 3-90-08560 Rev: 8 October, 2013 TL2.0 Woodburning Stove Hearth & Home Technologies welcomes you to our tradition of excellence! By choosing a Harman appliance, you have become part of our commitment to meeting the heating needs of consumers with the most distinctive, powerful and responsible home heating products available. With it's compact, steel-body construction, the TL2.0 features a heating capacity of 1600 to 1900 ft². The TL2.0 takes advantage of Harman’s 30+ years of stove design, technology and manufacturing. The Firedome Plus secondary combustion system provides for super-clean burning and minimal maintenance. The top-loading feature makes for more convenient loading, with enough fuel for an all day burn. We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing Harman. When This Room Heater Is Not Properly Installed, a House Fire May Result. To Reduce The Risk Of Fire, Follow The Installation Instructions. Contact Local Building Or Fire Officials About Restrictions And Installation Inspection Requirements In Your Area. Harman® A division of Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 www.harmanstoves.com This Label is located on the rear of the appliance. It contains important safety test information as well as the clearances to combustible materials. The label also contains the appliance serial number. For your records, copy your serial number and purchase date here. Serial #: ________________________ Date of Purchase: ________________________ LISTED SOLID FUEL FIREPLACE STOVE OR ROOM HEATER APPAREIL DE CHAUFFAGE OU POELE A COMBUSTIBLE SOLIDE MODEL/MODELE: TL 2.0 Report#/Rapport # 135-S-29-2 SERIAL Tested to/Teste a: UL 1482-2011, UL 737-2011 NUMBER/NUMERO DE SERIE: D F B C L E 008 A Meets requirements of ULC S627-00/Selon les exigences de ULC S627-00 Fireplace Stove, Also For Use In Mobile Homes In US only-With Outside Air Adapter #1-10-856082 PREVENT HOUSE FIRES: Install and Use Only in Accordance With Manufacturer’s Installation and Operating Instructions as well as Local Codes. In absence of any local codes, installation must meet minimum requirements of NFPA 211 in USA. Refer to manufacturer’s instructions and all local codes for requirements for passing chimney through a combustible wall or ceiling. FOR USE WITH SOLID WOOD FUEL ONLY. Do NOT Connect This Unit to a Chimney Flue Serving Another Appliance. Flue connector pipe must be 6” diameter, minimum 24 MSG black steel. Chimney must be factory built UL 103HT or a tile lined masonry. Inspect and Clean Chimney Frequently - Under Certain Conditions of Use, Creosote Buildup May Occur Rapidly. NOTE: Replace glass only with 5mm ceramic glass available from your dealer. This unit is approved for cooking using Harman grill #1-00-08121 - KEEP BYPASS DAMPER OPEN. Cet appareil est aussi approuvé pour utiliser la grille de cuisson Harman # 1-00-08121 - L'AMORTISSEUR DE DÉVIATION DOIT ÊTRE OUVERT DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS, YOU ARE OVERFIRING. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA. CONSULTEX LES ADMINISTRATIONS ET ORGANISMES COMPETENTS POUR LA CONSTRUCTION ET LA PREVENTION DES INCEDIES AFIN DE RESPECTER LES REGLES DE SECURITE EN VIGUEUR. Prevention des incendies: Respectez scrupuleusement les instructions du constructeur pour l’installation et l’utilisation. Respectez les regles et normes applicables dans votre region. Dans tous les cas, l’installation devra au minimum satisfaire aux exigences de NFPA 211 Etats-Unis. Reportez vous aux instructions du fabricant et aux regles locales pour les precautions necessaires lors du passage des tuyaux de fumee a travers un mur ou un plafond combustible. Controlez et nettoyez frequemment la cheminee et les tuyaux de fumee selon les instructions du fabricant. DANGER: Risk of Fire or Explosion - Do not burn garbage, gasoline, drain oil or other flammable liquids./ Risque d’incendie ou d’explosion. Ne brûlez pas d’ordures, d’essence, d’huile de vidange ni aucun autre liquide inflammable. Do not burn coal / Ne chauffez pas TROP N’UTILISIXZ QUE DU BOIS EN BUCHES: Ne pas raccorder ce poele a un conduit de fumee utilise pour un autre appareil. Le tuyau de fumee doit avoir 6” de diametre minimum, et etre en acier de qualite 24 MSG noir. Le conduit de fumee peut etre maconne ou de fabrication industrielle type ULC S629. Nota: Ne remplacer la vitre qu’avec une vitre ceramique de 45 mm disponible chez votre fournisseur. Controlez et Nettoyez Frequemment la Cheminee et les Tuyaux de Fumee. Dans Certaines Conditions D’utilization, des Accumulations de Cresote Peuvent se Produire Rapidement. NE PAS SUR CHAUFFER - SI LE POELE OU LE TUYAU ROUGISSENT, VOUS SURCHAUFFEZ LE P M L SA May be burned as a fireplace with “Cozy Screen” Part# 3-40-06960 in place over door opening. Otherwise, doors must remain closed during operation Peux fonctionner comme un foyer avec la pièce no. 3-40-06960 ‘’ Cozy Screen ‘’ placée au dessus de l’ouverture de la porte. Autrement , les portes doivent demeurer fermées durant le fonctionnement. Use ONLY Optional Blower Part # 1-00-856002. Pour ventiateur en option no, 1-00-856002 Seulemente. U.S. ENVIRONMENTAL PROTECTION AGENCY: Made in U.S.A. of US and imported parts. / Fabriqué aux États-Unis-d’Amérique par des pièces d’origine américaine et pièces importées. 2 Dry Seasoned Wood Only! 3-90-08560 DISTANCES MINIMALES DE SECURITE A - Entre le mur lateral et l’appareil 356 mm B - Entre le mur arriereet l’appareil 330 mm C - Entre le tuyau et le mur lateral 610 mm D - Entre le tuyau et le mur arriere 457 mm E - Entre le mur adjacent et l’appareil 406 mm F - Entre le tuyau et le mur adjacent 571 mm REFER TO PRODUCT MANUAL FOR CLEARANCES WITH ADDITIONAL VENT CONFIGURATIONS. tion de la ventilation. (200 mm) Floor protection must be a non-combustible material. Must ATTENTION:CHAUD LORS DU FONCTIONNEMENT- NE TOUCHEZ PAS L’APPAREIL-GARDEZ LES ENFANTS ET LES VÊTEMENTS ÉLOIGNÉS- TOUT CONTACT PEUT ENTRAÎNER DES BRÛLURES DE LA PEAU. RÉFÉREZ-VOUS À LA PLAQUE SIGNALÉTIQUE ET AU MODE D’EMPLOI. GARDEZ LE MOBILIER ET LES AUTRES MATÉRIAUX COMBUSTIBLES BIEN À L’ÉCART DE L’APPAREIL. B A CLEARANCE TO COMBUSTIBLE SURFACES A - Unit to Sidewall 14” B - Unit to Backwall 13” C - Chimney Connector to Sidewall 24” D - Chimney Connector to Backwall 18” E - Unit to Adjacent Wall 16” F - Chimney Connector to Adjacent Wall 22.5” E extending 2” (51mm) beyond each side of the connector. Pour protéger le plancher, il faut sous le poêle un matériau. Qui doit aussi être placé sous les parties horizontales du tuyau de raccord à la cheminée et s’étendre à 51 mm (2 po) au-delà de lateral du tuyau. Manufactured by / Fabriqué par: 8” 8” 200mm USA 8” 200mm CAN 18” 16” 457 mm 352 Mountain House Road-Halifax, PA 17032 (É.-U.) CAUTION: HOT WHILE IN OPERATION- DO NOT TOUCH- KEEP CHILDREN AND CLOTHING AWAY- CONTACT MAY CAUSE SKIN BURNS- SEE NAMEPLATE AND INSTRUCTIONS. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS A CONSIDERABLE DISTANCE AWAY FROM THE APPLIANCE. Date of Manufacture/Date de fabrication: 2011 2012 2013 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC Save These Instructions TL2.0 Woodburning Stove TABLE OF CONTENTS Section 1: Listing and Code Approvals A. Appliance Certifications B. Mobile Home Approval C. Glass Specifications D. Electrical Rating E. BTU & Efficiency Specifications 4 4 4 4 4 Section 2: Special Warnings and Notes A. Carbon Monoxide Warnings & Considerations 5 Section 3: Getting Started A. Design, Installation & Location 6 B. Fire Safety 6 C. Component Locator 7 D. Pre-Use Checklist 8 Section 4: Dimensions & Clearances A. Appliance Dimensions B. Clearances to Combustibles C. Floor Protection Section 9: Service & Maintenance A. Soot Formation (Removal) B. General Maintenance Procedures 27 28 Section 10: Reference Materials A. Wiring Diagram (Blower Option) B. Service Parts Listing C. EPA Hang Tag D. Warranty Policy 30 31 34 35 This room heater must be connected to: 1) A chimney complying with the requirements for Type HT chimneys in the standard for Chimneys, FactoryBuilt, Residential Type and Building Heating Appliance, UL 103 OR 9 10 12 2) A Code Approved Masonry Chimney with a Flue Liner. = Contains updated information Section 5: Chimneys and Venting A. Draft 13 B. Chimney Connectors 13 C. Wall Pass-Throughs 13 D. The Chimney 14 Section 6: Mobile Home - (US only) A. Mobile Home Installation 20 Section 7: Appliance Set-Up A. Outside Air Attachment B. Leveling The Appliance C. Optional Cooking Grill D. Optional Blower Kit E. Top Air Grill Option F. Brushed Stainless Trim option Section 8: Operating Instructions A. Fuel Specifications B. General Operating Information C. Burning as a Fireplace D. Combustion Process E. User Controls F. Before Your First Fire G. Building & Maintaining a Fire Save These Instructions 21 21 21 22 22 22 23 23 24 24 25 25 25 3-90-08560 Dry Seasoned Wood Only! 3 TL2.0 Woodburning Stove 1 Listing and Code Approvals A. Appliance Certification E. BTU & Efficiency Specifications Model: TL2.0 Woodburning Stove Laboratory: OMNI-Test Laboratories, Inc. Report No. 135-S-29-2 Type: Solid Fuel Room Heater / Wood Burning Type. Standard(s): UL1482-11, UL737-11 & ULC S627-00 Particulate Emissions Rating: *BTU Input: Heating Capacity: Firebox Size: Fuel: This appliance is also approved for installation in a shop. Shipping Weight: B. Mobile Home Approved This appliance is approved for Installation in mobile/ manufactured homes in the US only. The structural integrity of the mobile home floor, ceiling and walls must be maintained. The appliance must be properly grounded to the frame of the mobile home, and must never be installed in a room designated for sleeping. The unit must have provisions for an outside air source when installed in a mobile home. 2.6g/hr Avg 9,600 - 31,800 / hr 1,600-1,900 sq. ft.†† 2.0 cu. ft. Dry Cordwood 452 lbs. *BTU input based on EPA test fuel. Actual cordwood values will vary. ††Heating capacity based on zones 1 and 2, covering the Northern United States. C. Glass Specifications This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass if needed. D. Electrical Rating Optional Blower: 115 VAC, 60 Hz. <1 Amps 4 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning Stove 2 Special Warnings and Notes Carbon monoxide, referred to as CO, is a colorless, odorless gas that is produced during combustion of wood and other fuels. CO fumes are toxic and can be fatal. CO detectors are very sensitive and may sound an alarm for fumes other than CO or CO from sources other than the stove such as car or lawn mower exhaust. This appliance is a natural draft system which relies on a properly designed chimney to remove CO and other combustion by-products from the stove. If the alarm sounds 1. Increase ventilation by opening windows or doors. Even though this stove is designed to be as safe as possible, it is important that you install a CO detector. This is true for oil, gas, or coal burning products as well. CO is not specifically heavier or lighter than air. Therefore, it is best to install the detector at table top level rather than on the ceiling like a smoke detector. Never use gasoline, lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in this heater. Keep all such liquids well away from the heater while it is in use. SPECIAL NOTE: Due toash buildup, it is strongly recommended to have your stove professionally cleaned and serviced annually. This includes all parts of the stove, and the venting system. Save These Instructions 2. Make sure the stove doors and lid are closed and latched. 3. Check stove for smoking or puffing condition. Open bypass and increase air-flow to firebox, if needed. 4. Check chimney for possible blockage or down-draft. 5. Check for false alarm. NEVER CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. Installation and repair of this stove should be done by a qualified service person. We recommend that the stove be inspected before use and at least annually by a qualified service person. Periodic cleaning is required throughout the heating season and at the end of each winter for the stove to work efficiently. DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM. 3-90-08560 Dry Seasoned Wood Only! 5 TL2.0 Woodburning Stove 3 Getting Started A. Design, Installation & Location Considerations B. Fire Safety 1. Appliance Location Maintain the designated clearances to combustibles. Insulation must not touch the chimney. You must maintain the designated air space around the chimney. This space around a chimney is necessary to allow natural heat removal from the area. Insulation in this space will cause a heat buildup, which may ignite wood framing. NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction. Consideration must be given to safety, convenience, traffic flow, and the fact that the appliance will need a chimney and chimney connector. It is a good idea to plan your installation on paper, using exact measurements for clearances and floor protection, before actually beginning the installation. When installing on a combustible floor, proper floor protection material must be used. See page 12 for details. Maintain specified vent clearance to combustible requirements listed by the vent manufacturers instructions and all clearance to combustibles listed in this manual. To provide reasonable fire safety, the following should be given serious consideration: Check with your local building code agency before you begin your installation. Be sure local codes do not supersede UL specifications and always obtain the required permit so that insurance protection benefits cannot be unexpectedly cancelled. If any assistance is required during installation, please contact your dealer. 1. Install at least one smoke detector on each floor of your home. Detectors should be located away from the heating appliance and close to sleeping areas. Follow the smoke detector manufacturer's placement and installation instructions, and be sure to maintain regularly. 2. A conveniently located Class A fire extinguisher to contend with small fires resulting from burning embers. 3. A practiced evacuation plan, consisting of at least two escape routes. 4. A plan to deal with a chimney fire as follows: In the event of a chimney fire: a. Evacuate the house immediately. b. Notify Fire Department. c. Never apply water to a suspected chimney fire. Serious damage could occur. We recommend that a qualified building inspector and your insurance company representative review your plans before and after the installation. Be sure to provide a source of fresh air to the room or directly to the appliance. Make-up air is needed to replace what the chimney draws away through the appliance. Consider attaching outside air to the appliance. Certain conditions can create negative pressure within the dwelling. When this occurs, you may have trouble operating the wood stove. Worse yet, it may be strong enough to allow smoke leakage from the appliance. Installation on lower levels and in basements can be especially affected. ! ! CAUTION • Do NOT connect this unit to a chimney flue servicing another appliance. • Do NOT connect to any forced air distribution duct or system. 6 Dry Seasoned Wood Only! 3-90-08560 WARNING Fire Hazard • Do not operate appliance before reading and understanding the operating instructions. • Failure to operate properly may cause a house fire. Save These Instructions TL2.0 Woodburning Stove C. Component Locations Top Load Door Top Load Opening Bypass Damper Control Handle Front Load Door Bolt-Down Holes for Mobile Home Installations Air Control Ash Door Front Load Door Latch Ash Door Latch Save These Instructions 3-90-08560 Dry Seasoned Wood Only! 7 TL2.0 Woodburning Stove D. Pre- Use Check List 1. Place the appliance in a location near the final installation and follow the procedures below: 2. Open the appliance and remove all articles packed inside. Inspect all items for shipping damage. Notify dealer of any missing or damaged goods. 3. All safety warnings have been read and followed precisely. 4. This Owner's Manual has been read in it's entirety. 5. Floor protection requirements have been read and followed. 6. The flue connector has been installed in accordance with the instructions herein. 7. The proper clearances from the appliance and chimney connector to combustibles have been met. 8. The masonry chimney has been cleaned and inspected by a professional, or the factory built metal chimney is installed according to the manufacturers instructions. 9. The chimney meets the minimum height requirements. 10. All labels and hang tags have been removed from the glass. 11. All plated surfaces have been wiped clean, if applicable. 12. The optional air distribution blower has been installed properly. 13. A properly grounded electrical receptacle is available within reach of the blower's power cord (if installed). ! WARNING Inspect appliance and components for damage. Damaged parts may impair safe operation. • Do NOT install damaged components. • Do NOT install incomplete components. • Do NOT install substitute components. Report damaged parts to dealer. ! WARNING Fire Risk. Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions: • • • • • • • Installation and use of any damaged appliance. Modification of the appliance. Installation other than as instructed by Hearth & Home Technologies. Installation of parts or components not supplied or approved by Hearth & Home Technologies. Operating appliance without the legs attached. Operating appliance without fully assembling all components. Do NOT Overfire. Or any such action that may cause a fire hazard. 8 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning Stove 4 Dimensions & Clearances A. Appliance Dimensions 35.3" (897mm) 25.88"(657mm) 32.3" (820mm) Air Intake 9.1" (231mm) 23.9" (665mm) Weight..........................................452 lbs Flue Size........................................6 inch 26.0" (660mm) 18.4" (467mm) Centered The Harman TL2.0 meets the U.S. Environmental Protection Agency’s emission limits for wood heaters sold after July 1, 1990. Log Length Recommended........... 18" Average Emissions.......................2.6 Grams Per Hr. Outside Air size.............................4.5 inch I.D. Save These Instructions 3-90-08560 Dry Seasoned Wood Only! 9 TL2.0 Woodburning Stove B. Clearances To Combustibles Vertical Venting Configuration Location Single-wall Pipe A Unit to Side Wall 14" / 356 mm B Unit to Back Wall 13" / 330 mm C Vent Pipe to Side Wall 24" / 610 mm D Vent Pipe to Back Wall 18" / 457 mm Double-wall Pipe 14" / 356 mm 7" / 178 mm 24" / 610 mm 12" / 305 mm E Corner to Adjacent Wall F Connector to Wall 10" / 254 mm 16.5" / 419 mm Corner Installation 16" / 406 mm 22.5" / 571 mm D C B A F E F E *For clearance reduction methods, refer to NFPA 211 or Local Codes 10 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning Stove Vertical Venting Configuration - Horizontal Exit Location Single-wall Pipe A Unit to Side Wall 13" / 330 mm B Unit to Back Wall 13" / 330 mm C Vent Pipe to Side Wall 23" / 584 mm D Vent Pipe to Back Wall 18" / 457 mm E Vent Pipe to Ceiling 16" / 406 mm F G Corner Installation Corner to Adjacent Wall Connector to Wall 16" / 406 mm 22.5" / 571 mm C A 2' (610 mm) Minimum vertical prior to elbow. E D B E G F *For clearance reduction methods, refer to NFPA 211 or Local Codes Save These Instructions 3-90-08560 Dry Seasoned Wood Only! 11 TL2.0 Woodburning Stove C. Floor Protection Requirements Minimum Size floor protection (USA) is 48" Deep By 32.5" Wide. L Floor Protection Requirements Inches Millimeters J Sides- USA /CANADA * 8 203 K Front- USA /CANADA * 16 457 L Rear- USA 8 203 L Rear- CANADA Wall Wall * Floor protection dimensions for the front and sides are measured from the appliance door opening in The United States. In Canada, the side dimension is measured from the widest part of the appliance. Minimum 60" corner floor protection (CANADA). 54" K J J Floor Protection Requirements 54" If the appliance is being installed on a combustible floor, non-combustible floor protection must be installed. In all installations, the area under and around the stove must be protected from falling ash and live coals. The area under a horizontal run of chimney connector must also be protected, extending two (2) inches (51mm) to each side of the horizontal connector. Further guidelines for floor protection are as follows: In the U.S. the floor protector must be completely under the stove, and extending 18" in front of the door opening, 8" to each side of the door opening, and 8" to the back. In Canada, the floor protection must extend 18" (457mm) in front of the door opening, and 8" (203mm) to each side of the appliance, and to the rear. 12 Dry Seasoned Wood Only! Alternate floor protector dimension may be used as long as they satisfy the measurement requirements shown above. Minumum size floor protection for a corner installation hearth pad is 54" x 54" (USA ONLY). 3-90-08560 Save These Instructions TL2.0 Woodburning Stove 5 The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a Floor or Ceiling. Chimneys & Venting A. Draft Draft is widely misunderstood. It is important that you, the stove operator, realize that draft is a variable effect, not a given quantity. Stoves and chimneys do not have draft, yet draft is the key to your stove’s performance. Draft is a force, produced by an operating stove and the chimney to which it is attached. It is created by hot gases rising up the chimney, creating a pressure difference between the inside of your home and the outside air. It continually moves fresh combustion air into the stove, and hot exhaust gases out of the stove; without this constant flow, the fire will go out. Other factors, such as barometric pressure, winds, the airtightness of the home, the total inside chimney volume, chimney height and the presence of venting devices such as exhaust fans also play a role in maintaining an adequate draft. Low barometric pressures, super insulated homes and exhaust fans can reduce draft; winds can play havoc with draft; and too large or too small a chimney volume can cause reduced draft due to the excessive cooling or not enough room to vent exhaust gases. Introducing outside air directly to the stove may help remedy a low draft problem. Some signs of inadequate draft are smoking, odor, difficulty in maintaining the fire, and low heat output. Overdraft can be caused by a very tall chimney even if it is the recommended size, and can cause overfiring of your stove. Signs of an overdraft include rapid fuel consumption, inability to slow the fire, and parts of the stove or chimney connector glowing red. It is important that you follow the chimney guidelines in this manual, including size, type, and height to avoid draft problems. When installed and operated according to this manual, the stove will produce enough hot gases to keep the chimney warm so that adequate draft is maintained throughout the burn cycle. B. Chimney Connectors In general, following these guidelines will ensure compliance with all national and provincial codes; prior to beginning your installation, check with your local building code official to check on additional local regulations which may influence the design and placement of your venting system. The Harman TL2.0 may be installed with a minimum (.6 mm) 24 gauge blue or black steel, chimney connector pipe. The size of the connector should correspond to the size of the flue collar opening, which is 6" (152mm). Do not use makeshift compromises. No part of the chimney connector may pass through an attic or roof space, closet or other concealed space, or through a Save These Instructions floor or ceiling. Whenever possible, avoid passing the connector through a combustible wall; if you must, use an approved wall pass-through, described later in this section. Assemble the connector beginning at the flue collar, with the crimped ends pointing towards the stove (to keep debris or residue inside the system). Each joint, including the one to the stove’s flue collar and the one to the chimney itself should be secured with at least three sheet metal screws. Screws may be a maximum of 3 inches apart. A 1-1/4" (30 mm) overlap is required at each joint, including the flue collar attachment. No more than two 90 degree elbows should be used, and the total length of connector should not exceed 10 feet (3 m). All horizontal runs of connector must have a minimum upward slope of 1/4" per foot (20 mm per meter). C. Wall Pass-thrus Depending on your local building codes, and the pertinent provincial or national codes, there are several choices for passing the chimney connector safely through a wall. Before beginning your installation, contact local officials, and also the chimney connector and chimney manufacturer for specific requirements. Canada. Three methods are approved by the Canadian Standards Association. The diagram on the next page shows one method requiring an 18"(450 mm) air space between the connector and the wall. It allows use of one or two covers as described in the diagram. The two other methods are described in detail in the current issue of CAN/CSA B365, the national standard. United States In the U.S., the national code is NFPA 211. While many localities adopt this standard, be sure to check with local authorities before beginning your installation. The NFPA (National Fire Protection Agency) permits four methods for passing through a combustible wall. A commonly used method to pass through a wall directly to a masonry chimney is to clear a minimum 12"(300 mm) around the entire chimney connector, and fill it with brick masonry which is at least 3.5"(90 mm) thick. A fireclay liner, minimum 3/8" (9 mm) wall thickness must run through the brick wall to the chimney liner (but not beyond the inner surface of the liner). It must be cemented in place with refractory cement. This method is illustrated on the next page. For details on the other three options, refer to the most recent edition of the NFPA 211 code. 3-90-08560 Dry Seasoned Wood Only! 13 TL2.0 Woodburning Stove Closest Combustible Material Minimum 2” (50mm) Clearance to Brick Liner Minimum 12” (50mm) to Brick Fire Clay Thimble Chimney Flue Hole with minimum clearance of 18” (450mm) Between connector and wall. Non-combustible cover, one side only. If two covers are used, each must be mounted on non-combustible spacers at least 7/8” (21mm) away from the wall. Masonry Chimney Built to NFPA 211 Specifications 1” (25mm) Clearance Minimum 12” (300) to Combustibles AN APPROVED U.S. WALL PASS-THROUGH AN WALL PASS-THROUGH ANAPPROVED APPROVEDCANADIAN CANADIAN WALL PASS-THROUGH AN APPROVED U.S WALL PASS-THROUGH D. The Chimney This unit must be installed into a chimney approved for use with solid-fuel appliances. In the U.S., it must be connected to (1) a prefabricated chimney complying with the requirements for Type HT chimneys in the Standard for Chimneys, FactoryBuilt, Residential Type and Building Heating Appliances, UL 103, or (2) a code-approved masonry chimney with a flue liner. In Canada, this unit is listed for use with prefabricated chimneys tested and listed to the high temperature (650 degrees C) chimney standard, ULC S-629, or with a code approved masonry chimney. Do Not Connect This Unit to a Chimney Flue Serving Another Appliance. NOTE: The restriction of not venting more than one appliance to the same flue applies to the U.S. specifically. While it is not recommended that you use the same chimney for more than one appliance, in Canada certain exceptions may be made. Be sure to contact your building code inspection official to see if this option is allowed in your area, and to find out the specific requirements for such an installation. More than 10 Ft. (3 m) For mobile homes, (US only) it must only be installed with a factory built stainless steel chimney. The chimney system should include all required installation components, such as vapor barriers and roof flashing, as tested for use in mobile homes. The minimum recommended height for any chimney is 16 ft. (4.8 m) above flue collar height. For non-mobile home installations, a round flue (either masonry or approved prefabricated), of either 6" (150 mm), 7" (180 mm) or 8" (200 mm) may be used. For square or rectangular masonry chimneys, nominal sizes of 8" x 8" or 7" x 12" (200mm x 200 mm, 180 mm x 300 mm) may be used. Codes require that solid-fuel chimneys extend 3 ft. (0.9 m) above the highest point at which they exit from the roof. Then, the chimney must extend 2 ft. (0.6 m) above the highest point within a 10 ft (3 m) radius. Thus, the 3 foot, 2 foot, 10 foot rule: 3ft. - Above roof exit point 2ft. - Higher than anything within10ft. of the chimney. 14 Dry Seasoned Wood Only! Chimney Connector 3-90-08560 10 Ft. (3 m) Height necessary above any roof surface within 10 Ft. (3 m) 2 Ft. (.6 m) Min 3 Ft. (.9 m) minimum above exit point Ridge Chimney The 3-foot, 2-foot, 10 foot rule Save These Instructions TL2.0 Woodburning Stove 1. Existing Masonry Chimneys If you plan on using a pre-existing masonry chimney, have it thoroughly inspected and cleaned. Any faults which make the chimney unsafe and unusable must be repaired prior to use. These can include improper height, structural defects, blockages, inadequate clearance to combustibles, unsealed openings into other rooms of the house, signs of creosote or smoke leakage, a loose or absent clean-out door, or absence of a liner. Chimney liner inner edges Mechanical fasteners (minimum 3) but not at the bottom of the connector 2. Venting to a Masonry Chimney When connecting to a masonry chimney, several provisions are standard. First, whether the chimney connector is vented to the chimney through a thimble or a breech pipe, neither must pass beyond the inner surface of the chimney liner, and both must be firmly cemented in place with refractory cement. (A thimble is a masonry pipe which is inserted through the chimney wall, and is frequently the preferred method; a breech pipe is a piece of steel pipe used the same way.) In Canada, a breech pipe has ridges or protrusions to lock it firmly into the refractory cement. In either case, the chimney connector vents to the chimney through the thimble or breech pipe. Using a thimble, the connector slides completely inside the masonry to the inner edge of the flue liner, and may be easily removed for chimney and connector inspection. A breech pipe must extend at least 2" (50 mm) into the room, so the connector can be attached with sheetmetal screws. 3. Venting to a Masonry Fireplace Chimney In some situations, a code compliant chimney originally used for a masonry fireplace may be used. In addition to the requirements found in the previous paragraphs, it is important to be aware that all clearances must be met, including those from the chimney connector to combustibles. Do not forget to include floor protection in your plans. (See Clearances and Floor Protection in this section.) Since many fireplaces have exposed wooden mantels and trim, pay special attention to the clearances necessary to these materials. If your fireplace chimney is behind a combustible wall, you must use an approved wall pass-through system to gain access to the masonry chimney. The chimney connector must enter the chimney at a place where it is lined, and the fireplace must be made inoperable. For example, you might remove the damper, replacing it with a secure, airtight, noncombustible seal (removable for inspection); this also satisfies the requirement that no room air must be allowed to enter the chimney. Chimney Connector Clay thimble, reaching just to the inside of the chimney liner High-temperature sealant used to cement the clay thimble 4. Installing to a Prefabricated Chimney When venting using a prefabricated chimney, be sure to contact local building code authorities, and to follow the manufacturer’s instructions exactly. Use only the manufacturer’s parts; do not use makeshift installation techniques. All prefabricated chimneys must be tested to either the U.S. or Canadian high-temperature standards, UL 103 or ULC S629. 5. Other Considerations Do not burn any fuel other than dry cordwood. Never use highly volatile substances in your stove, such as gasoline, which could cause an explosion. When solid fuels are burned completely, they produce water and carbon dioxide. However, in long slow burns, a substantial amount of carbon monoxide may be produced. If allowed to build up, carbon monoxide (which is odorless) can prove fatally poisonous. Proper ventilation and draft will prevent this from happening. If you smell smoke, thoroughly ventilate your dwelling, and contact your dealer for service. Other causes of poor ventilation or draft are icing, exhaust fans, a blocked outside air inlet, and room air starvation. If your stove is sluggish and you get occasional odor, check these possibilities and increase the air flow in your home. The Chimney and connector must be maintained in good condition and kept clean. Save These Instructions 3-90-08560 Dry Seasoned Wood Only! 15 TL2.0 Woodburning Stove Standard Ceiling Installation with Factory Built Chimney Chimney Cap Chimney Sections Storm Collar Roof Flashing Roof Radiation Shield Attic Radiation Shield Minimum Air Space with Chimney Listing Chimney Support Chimney Connector The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a Floor or Ceiling. 16 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning Stove Cathedral Ceiling Installation with Factory Built Chimney Chimney Cap Roof Radiation Shield Factory-Built Metal Chimney Sealed Storm Collar Roof Flashing Cathedral Style Chimney Support Finishing Collar Chimney Connector Save These Instructions 3-90-08560 Dry Seasoned Wood Only! 17 TL2.0 Woodburning Stove Chimney Breach Fireplace Conversion with Non-Combustible Wall Minimum clearance to unprotected ceiling 15” Chimney connector sealed at thimble Flue liner with required air space Airtight insulated clean-out Minimum of three sheet metal screws per joint of chimney connector Mantel and trim protection Floor Protection* Damper closed and sealed with non-combustible material Combustible Floor *Floor protection in accordance with Solid Fuel Appliance Listing The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a Floor or Ceiling. 18 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning Stove Chimney Breach Fireplace Conversion with Combustible Wall 1” Clearance for exterior chimney or 2” clearance for interior chimney and 2” clearance for NFPA 211 - type approved thimbles Flue liner with required air space Minimum clearance from chimney connector to uprotected ceiling 15” Listed or approved thimble assembly Mantel and Trim Protection Combustible Wall Sheet Rock Airtight insulated clean-out Floor Protection* Damper closed and sealed with non-combustible material Combustible Floor * Floor protection in accordance with Solid Fuel Appliance Listing ** Check with your local building codes inspector for clearance. * Floor Protection in Accordance with Solid Fuel Appliance Listing ** Check with your local building codes for clearance. The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a Floor or Ceiling. Save These Instructions 3-90-08560 Dry Seasoned Wood Only! 19 TL2.0 Woodburning Stove 6 Mobile Home A. Mobile Home Installation NOTE: The top sections of the chimney must be removable to allow a maximum clearance of 13.5 feet (411cm) from ground level for transportation purposes. Mobile home approval - U.S. only. DO NOT INSTALL IN A MOBILE HOME IN CANADA. 1. An outside air inlet must be provided for combustion air, and must remain clear of leaves, debris, ice, and/or snow. The outside air path must be unrestricted while the appliance is in operation. Use Kit #1-10-856082 to attach to unit. 2. The combustion air intake system must be of metal construction. It must permit zero-clearance to combustible materials, and contain a rodent screen. 3. The appliance must be secured to the mobile home structure by bolting it to the floor. There are holes provided in the pedestal base. Secure with the proper length lag bolts, through the hearth pad and into the home floor. 4. The appliance must be grounded to the metal framing of the mobile home 5. All clearances to combustibles and floor protection requirements must be followed. 6. Follow the vent manufacturer's instructions when installing in a mobile home. Must be connected to a UL103 HT ventillated chimney connector, UL103 HT chimney, and terminal cap with spark arrestor. 7. Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the exterior. 8. Installation shall be in accordance with the Manufactured Home and Safety Standard (HUD) CFR 3280, Part 24 9. The appliance must never be installed in a room designated for sleeping. 10. Burn wood only. Other fuels may generate poisonous gases (carbon monoxide). 11. If unit burns poorly while an exhaust blower (range hood) is operating, increase the supply of combustion air to the appliance ! Chimney Cap Roof Flashing Roof Radiation Shield Attic Radiation Shield Minimum Air Space with Chimney Listing Chimney Support Chimney Connector Outside Air CAUTION the structural integrity of the mobile home floor, wall and ceiling/roof must be maintained. Do NOT cut through: • Floor joist, wall studs, or ceiling trusses. • Any supporting material that would affect the structural integrity. ! Storm Collar Chimney Sections ! WARNING Installation must comply with Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24. WARNING Do not install in sleeping room. 20 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning Stove 7 Appliance Set-Up A. Outside Air Attachment B. Leveling the Appliance Parts and Supplies Needed: Kit #1-10-856082, 1 piece of metal flexible pipe, 4" X needed length. 1 Rodent Screen, and aluminum tape. Plus, a trim ring for finishing around the pipe on the inside wall. Use metal shim material under the pedestal base where needed for leveling. 1. Determine an appropriate hole location, through the wall. Be sure there are no studs or other supporting members. Also ensure there are no electrical wires or plumbing contained within the wall. 2. Make the hole through the exterior wall using a hole saw or reciprocating saw. You'll want the hole to be just slightly larger than the metal flex pipe. 3. Attach the rodent screen to one end of the flex pipe, and insert it through the wall until the back of the screen cover is against the outside surface. 4. Hold the flex pipe in place to make an accurate determination of the length needed. Cut the flex pipe to length. 5. Slide the trim ring onto the flex for the inside wall portion. 6. Slide the other end of the metal intake flex pipe into the stub on the rear of the stove and secure it with aluminum tape. This air intake will supply outside air for the secondary combustion. 7. Secure the trim ring in place for finishing the inside wall area. 8. Seal around the rodent screen on the exterior wall, using silicone caulking. ! C. Optional Cooking Grill The optional cooking grill #1-00-08121 installs easily in the top load opening of the stove. The grill handle (B) fits in the slots (C) on each side. To remove the handle, lower and turn. When installed, the grill hangs in the opening by the hooks (A). A B A CAUTION Never draw outside combustion air from: • Wall, floor or ceiling cavity. • Enclosed space such as an attic or garage C A C When grilling, you'll want to keep the fire size small and the bypass damper in the open position. Depending on the grilling being done, you may get grease dripping on the glass causing it to become dirty and obstructed. When you burn your next hot fire, the glass will likely clean itself. Outside Air Attachment Save These Instructions KEEP TOP LOAD DOOR CLOSED EXCEPT WHEN LOADING OR UNLOADING GRILL. 3-90-08560 Dry Seasoned Wood Only! 21 TL2.0 Woodburning Stove D. Optional Blower Installation E. Top Air Grill Option Use ONLY Blower Part #1-00-856002 With This Appliance. The top air grill installs over the flue collar and simply rests on the top of the stove. The brushed stainless grill is included with this option as well. The optional blower kit installs easily to the rear of the TL2.0. First, remove the air jacket shield from the rear of the stove. Use the same four bolts to attach the blower as shown. F. Brushed Stainless Trim Kit Option The trim kit consists of three pieces; Load door trim, Ash lip trim, and the Ash door frame. To install the load door trim, it is best to remove the door by lifting from the hinges. lay the door down flat on it's face. Drill the dimpled holes in each corner of the door and re-install the door onto the stove. From the outside, install the frame with the studs going through the newly drilled holes and install the nuts on the inside. To install the ash lip trim, just slide it onto the ash lip. You may attach with silicone if desired. The ash door frame uses a spring clip on one end to hold it into the recessed area of the ash door. Install the clip in the frame channel and push that end into the door opening until the other end of the frame fits. ! WARNING Route Power cord away from the appliance. Do not run the cord under or in front of the appliance. Plug the blower into a properly grounded electrical outlet. Keep the blower on low speed or off during low fires. As you get out of the low burn range, the speed can be set wherever desired, or kept off. 22 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning Stove 8 Operating Instructions ! CAUTION ! WARNING B. General Operating Information Approved for use with wood fuel only. The use of any other fuel will void the product warranty and may cause damage to the appliance and/or your home. "NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO START OR "FRESHEN UP " A FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE Heater / fireplace stove WHILE it is IN USE". A. Fuel Specifications Select only dry, seasoned wood. Wood for burning should never be exposed to rain or extremely damp conditions. Hardwoods are favored because they are heavier and contain more heating capacity (BTU’s) per load than do softwoods. Fuel wood should be split and stored under cover for “seasoning” - at least a year is recommended. Your stove is not an incinerator - do not burn garbage, painted or treated wood, plastic, or other debris. Keep the area around the stove free from clutter. Keep all combustibles, including fuel, beyond the code-required clearance distance (48" or 1215 mm in the U.S., 1525 mm or 60" in Canada). Never store fuel in front of the stove where it could interfere with door operation, safe loading, and ash removal. ! CAUTION Always wear fire retardant gloves when operating the stove. SAFETY NOTICE IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW INSTALLATION DIRECTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. 1. Draft Before you install and/or operate your wood stove, please read the entire contents of this manual. Pay particular attention to the explanation of draft and its effect on stove performance in the Installation section. By following the installation and operating guidelines, you will ensure proper draft and gain maximum efficiency and enjoyment from your stove. Do not alter the position of the andirons. Building a fire too close to the glass may cause damage to the glass, creating a serious risk of fire and property damage. 2. Doors Your stove has a large glass-paneled door for loading and fire viewing, a separate smaller door for removing ashes and a top loading door. Front Door Before opening, always check for wood, embers, or ash that may be ready to fall out of the door. To open the glass door, open the bypass damper first, then turn the handle clockwise and pull out; to close the door, push the door closed with the handle in the open position, then turn, counter-clockwise, to engage the latch. Ash Door To open the ash door, lift up the handle and pull out. Close the door by pushing in and pushing the handle all the way down. Top Load Door To open the top load door, open the bypass damper and then lift to open the top load door. All doors must be closed while the stove is in normal operation, and the gaskets routinely examined for wear and replaced when necessary. Good door seals are important for maintaining control of the stove. Never operate with the ash door open. Operating the stove with the ash door open, or with a door inadequately sealed, could create a serious overfiring condition (discussed later in this section). The glass used in your stove is manufactured to exact standards to withstand the high heat of the fire, but like all glass, it must be treated with common sense and care. Never abuse the glass by slamming the door shut or striking the glass with a heavy object. If the glass is broken or damaged, do not operate the stove until it has been replaced (See instructions in the Maintenance section.) Do not burn garbage or flammable liquids such as gasoline, naptha, or engine oil. Save These Instructions 3-90-08560 Dry Seasoned Wood Only! 23 TL2.0 Woodburning Stove 3. Grates The unique grate system consists of one flat bottom grate, and two front andirons. The bottom grate has slots which allow the ash to fall into the ash pan by passing a poker back and forth across the grate. The andirons keep the fuel from coming into direct contact with the glass, and keep hot coals and embers from spilling out while reloading. Never build a fire directly against the glass. The grates and andirons must remain in place at all times. Do not tamper with or change the configuration of this grate system. C. Burning as a Fireplace This appliance has been tested and approved for burning as an open fireplace. To do so, a spark screen (Harman part# 3-40-06960; Cozy Screen) must be installed over the front door opening. The by-pass damper must be kept in the open position. The Cozy Screen can be used from the start of a fire or can be used with an existing one. When starting a fire with the Cozy Screen, smoke spillage may occur until it develops a draft strong enough to pull all smoke back into the flue. DO NOT LEAVE THE APPLIANCE UNATTENDED WITH THE DOOR OPEN! Load only small amounts of wood at a time. D. The Combustion Process Combustion in the firebox is precisely controlled and is best explained in two parts. During a wood fire, combustion air enters at the bottom front of the stove where it travels upward through channels at either side of the front door. From the manifold located above the front door, it is directed into the firebox as a sheet of air flowing between the glass and the wood. This concept helps to keep the glass clean, while providing the oxygen needed to sustain burning. This is what is known as "Primary Combustion". Additional air enters at the bottom rear of the stove body. Some of this air enters through holes in the rear bricks where it is used to revitalize the fire at the rear of the firebox. The remainder is delivered into the "Firedome Plus" combustion package where the "Secondary Combustion", or re-burning of the smoke, occurs. During combustion, the burning of wood proceeds through several stages. The initial or evaporation stage is where the moisture in the wood is driven off in the form of steam. A second stage is where the volatile gases contained in the wood are released and burned. This represents most of the wood's heating capacity. The final stage is the charcoal stage where the charcoal burns the remaining heat content in the wood fuel. Ash remains after the burning is complete. Within the primary firebox two or more of these stages of combustion are occurring at once. Always be sure to provide adequate ventillation to the room where the apliance is located, to prevent air starvation. In tight construction, consider installing outside air to the appliance. EXHAUST STREAM SECONDARY AIR THRU BRICK SECONDARY AIR ENTERING EXHAUST STREAM PRIMARY AIR FLOW SECONDARY AIR FLOW 24 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning Stove E. User Controls Two important controls - the damper bypass handle and the air control lever regulate the operation and output of the stove. To open the top or front loading door, you must open the damper bypass, or smoke will come in the room. In this mode of operation the combustion gases go directly from the main combustion chamber to the flue collar and exit into the chimney. NOTE: The bypass damper must be open for smokeless loading. Open the bypass damper by turning the handle clockwise while facing handle. For low burn, slide the air control to the left. For medium burns, use notches 1 to 2. Maximum heat is attained with the air control all the way to the right. Do not burn the stove continuously at the maximum setting. If maximum heat is required day after day, the stove is too small for the area you are trying to heat. If your wood is not seasoned long enough or is high in moisture content, you may need to adjust the primary air slightly higher to sustain a low burn rate with the cleanest possible exhaust. F. Before Your First Fire • Be sure the appliance is installed properly and that all safety requirements have been met. Pay particular attention to the clearances to combustibles, floor protection and the venting instructions. • Test your smoke detector(s) and CO detector(s) to the specifications of the manufacturer. • Double check that the ash pan and internal firebox are empty. Damper Open • Be sure to read this entire manual. Damper Closed ! CAUTION do not overload the appliance. If YOu can not close the lid or door, you have overloaded. Begin with the bypass damper open, and the air control lever at the maximum setting, all the way to the right. Be sure the ash pan door is closed and latched. Minimum Primary Air Start with a bed of crumpled paper and kindling sized about finger width; place several 1" - 2" (25mm - 50mm) split pieces of dry wood on top of the kindling, followed by a few 2" - 3" (50 mm - 80 mm) split pieces. Lay the wood in a crossed pattern to allow maximum air flow. Ignite the paper and close the loading door(s). Allow this start-up fire to burn for a few minutes, keeping the bypass damper open. Add about five more pieces of wood in the 2 to 3 inch (50 - 80mm) size range, making sure that the fuel bed is all the way across the firebox and staggered to allow airflow. Close the door and allow this loading to burn a few minutes. Maximum Primary Air The air control lever is located on the ash lip, below the load door. Sliding this lever allows you to vary the amount of air to the fire, creating a range of heat outputs. The lowest heat output setting is to the left, and the highest is to the right. The notches are provided as a reference for your comfortable heat settings. Do not, under any circumstances, alter the configuration or operation of the air control lever. Save These Instructions Add increasingly larger pieces of wood to the fire until you have a thick bed of hot embers, approximately 2 to 3 inches deep at the back of the grate and at least an inch deep at the front. You must have this charcoal bed established before you close the bypass damper. 3-90-08560 Dry Seasoned Wood Only! 25 TL2.0 Woodburning Stove Providing you have the charcoal bed described, close the bypass damper by pulling the handle toward the front of the stove. This will begin the highly efficient mode of operation where the exhaust gases get re-burned in the secondary combustion package. If you cannot achieve a charcoal bed within the first 15 to 20 minutes, your wood is likely too wet, and you may need to burn the fire longer and/or hotter to compensate for the extra energy needed to drive out the moisture. If, after five minutes of burning with the damper closed, smoke is visible coming from the chimney, you probably do not have the proper coal bed. Open the bypass damper and continue with the process until a significant coal bed is formed. DISPOSAL OF ASHES; Ashes should be placed in a steel container with a tight fitting lid. The container of ashes should be moved outdoors immediately, and placed on a noncombustible floor or the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have completely cooled. Other waste shall not be placed in this container. Always remember to open the bypass damper when you are loading, this allows the exhaust gases to pass directly into the flue outlet and reduces the chance of smoke spillage into the room. hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns. Reloading: Once you have prepared and maintained a thick charcoal bed, and the secondary combustion is established, you should be able to reload the stove at any time by simply opening the bypass damper, then the load door, adding fuel and closing the door then the damper. This depends on coal bed size, load size and moisture content of fuel. Removing Ashes: Before reloading, empty the ash pan (remember to close the ash door while emptying the pan). The ashes should be the coolest at this time. Remove ashes from the fire chamber periodically by raking a poker across the bottom grates. Excessive ash buildup can prevent proper venting of exhaust gases. Do not allow the ash pan to over-fill. Ash buildup between the ash pan and the bottom of the grate can cause the grate to overheat and wear out prematurely. The TL2.0 is designed to provide access to the ash pan without the need for opening the main door. Before opening the ash door and removing the ash pan, open the bypass damper. Wearing heavy protective gloves, open the ash door and remove the ash pan by pulling it forward by the handle. Close the ash door and damper bypass before taking the ashes outside for safe disposal. ! CAUTION Never leave the stove unattended if either the ash or load door is open. Overfiring may result. Risk of Excessive Temperatures. Keep Ash Door Closed During Firing of the Heater. Avoid overfiring your stove. Overfiring is a potentially hazardous situation which can lead to overheating of combustible materials nearby, damage to the stove, and in extreme cases, cause a fire. Overfiring is caused by: 1. Too much air flowing through the stove too quickly. 2. You may have positioned the primary air control lever too far to the right. 3. Inadvertently leaving the damper open or 4. Not keeping up with routine maintenance, such as checking door gaskets for wear. Overfiring results in excessive fuel consumption, and may cause parts of the stove or chimney connector to glow red. If you notice signs of overfiring, reduce the air supply to the fire, and review the Maintenance section in this manual. In the event of a chimney fire, call your local fire department; make sure everyone is safely out of the house. Reduce the air intake of the stove as much as possible using the air control lever; close the bypass damper to further restrict air flow. Do not throw water on the fire; this can cause stove damage and create an even more dangerous situation. Have your chimney professionally cleaned and inspected before resuming burning in your stove. As you begin to operate your stove at higher temperatures, you will notice a “hot” or unpleasant smell; this is just the paint going through the curing process, and will disappear after a few fires. 26 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning Stove 9 Solid fuel burning spave heaters must be cleaned regularly, as soot, ash and creosote may accumulate. Service & Maintenance A. Creosote- Formation and Need For Removal; When wood is burned slowly, it produces tar and other organic vapors which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire. The chimney and chimney connector should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred. If creosote has accumulated, 3mm or more, it should be removed to reduce the risk of a chimney fire. If you experience a chimney fire; Close the air control and bypass damper and notify the fire department. Do NOT apply water to the fire, in the firebox or in the chimney. Do not operate the appliance until the chimney and connector have been inspected and approved by a chimney professional. Do not burn any fuel other than wood, such as charcoal, which can cause increased carbon monoxide production or overfiring. Never use highly volatile substances in your stove, such as gasoline, which could cause an explosion. When solid fuels are burned completely, they produce water and carbon dioxide. However, in long slow burns, a substantial amount of carbon monoxide may be produced. If allowed to build up, carbon monoxide (which is odorless) can prove fatally poisonous. Proper ventilation and draft will prevent this from happening. If you smell smoke, turn up the air control lever setting, and thoroughly ventilate your dwelling. During future burns, be careful not to overload the stove with fuel, so you will not be tempted to constantly operate at a low air control setting. Other causes of poor ventilation or draft are icing, exhaust fans, a blocked outside air inlet, and room air starvation. If your stove is sluggish and you get occasional odor, check these possibilities and increase the air flow in your home. When properly maintained, your stove will give you many years of trouble-free service. Contact your dealer to answer questions regarding proper operation, trouble-shooting and service for your appliance. Visit www.harmanstoves.com to find a dealer. We recommend annual service by a qualified service technician. Seasonal cleaning At least once per year, the stove, venting connectors and chimney should be thoroughly cleaned. If the areas are found to have an excessive build up of ash or creosote, it is recommended to increase the frequency of the cleaning. This will extend the life of the appliance and its components. A vacuum specifically designed for ash is preferred, however a standard shop-style vacuum with a HEPA filter may also work just fine. During cleaning, caution must be taken not to damage the white / gray colored ceramic combustion package in the rear of the firebox. When using a brush in the chimney or venting connector, the by-pass damper should be placed in the open position to help prevent ash, creosote or other debris from falling down onto and around the combustion package. This also protects the top of the combustion package from tool or brush damage and diverts most of the removed materials into the firebox for easy clean-up and removal. Once the venting system has been cleaned, remove the first section of connector pipe from the appliance flue collar. Carefully vacuum the ash and debris from around the sides and top of the combustion package. The shoe brick must be removed to allow vacuum access for cleaning the front portion of the combustion package. Always use caution when refueling or when vacuuming the firebox and combustion package. Some users have damaged their combustion package with vacuum cleaner tools, and fire pokers. ! CAUTION Always wear fire-resistant gloves to operate the stove. The air control is hot while in operation. Save These Instructions 3-90-08560 Dry Seasoned Wood Only! 27 TL2.0 Woodburning Stove B. General Maintenance Procedures 2. Door Glass • Frequency: As needed / Weekly • By: User 1. Ash Removal • Frequency: As needed / Every day or two • Whenever the view of the fire is obstructed, or weekly, clean the glass using a soft cloth dampened with standard household glass cleaner. By: User Wear Leather Gloves To Prevent Skin Burns! Open the ash removal door by lifting upward on the latch handle, then swing the door open. Pull the ash pan out of the firebox, using the lip on the front of the pan. Once the ash pan is removed from the stove, you can flip the carry handle up for convenience. ! CAUTION DO NOT CLEAN GLASS WHEN HOT. Allow glass to cool before cleaning. If removing ashes while a fire is burning, close and latch the ash door while disposing of the ashes. never use abrasive materials on the glass. DO NOT leave the appliance unattended with the ash door open. Fly-ash allowed to accumulate on the glass may lead to permanent fogging or "crazing" of the glass. Inspect the glass and sealing gasket. Replace gasket as needed. Do not operate the stove with a broken glass. Replacement glass, which is ceramic glass, should be obtained only through your Harman dealer. To replace a broken glass; first be sure to carefully remove the broken glass and any remaining shards or pieces. With the door laying on a flat surface, lay the gasketted glass panel onto the door and be sure it is properly fitted into the channel. Lay the glass retainer clips in place near each corner, and secure them using the 3/8" screws. Be sure to tighten each screw equally so you don't create a pressure point on the glass. WARNING! Do NOT Use Substitute Material for Glass Replacement. Glass Retainers Glass Retainer screws Glass Panel DISPOSAL OF ASHES; Ashes should be placed in a steel container with a tight fitting lid. The container of ashes should be moved outdoors immediately, and placed on a noncombustible floor or the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have completely cooled. Other waste shall not be placed in this container. Glass Gasket Door Frame Glass Specifications: 5mm X 419mm X 314mm arched. ! WARNING Do not abuse glass by striking or slamming the door closed. This type of breakage is not covered by the product warranty. 28 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning Stove 3. Firebox • Frequency: As necessary / Yearly 5. Chimney Connector • Frequency: As necessary / Yearly • • By: User Cleaning the firebox and internal heat exchange surfaces is recommended to maintain thermal efficiency. Depending on the quality and quantity of fuel being used, you may want to perform this cleaning monthly. Be sure to clean these areas thoroughly at the end of the heating season. Brush and vacuum all internal surfaces at the end of the heating season. Ashes will draw moisture and may promote rust formation. 4. Blower- If installed • Frequency: As necessary / Yearly • By: Qualified Service Technician / User At the end of the burn season, brush and clean all sections of chimney connector pipe. Some owners remove the chimney connector for the off season. Any ashes left in the connector pipe will actually draw moisture which promotes rust. This is why it is very important to clean all ashes at the end of the heating season. When cleaning the chimney connector above the appliance, keep the bypass damper in the open position. This will keep any loosened material from falling into the Firedome Plus combustion chamber. By: User Chimney Connector The fan on the blower will collect pet hair and other debris over time. Any accumulation must be removed to maintain proper operation. To clean blower; • Disconnect Power Cord Before Servicing. • Remove the four bolts that hold the blower in place. • You will find it easiest to use an air hose and blow the debris from the blower housing. • Alternately, with some minor disassembly, you can use a vacuum and/or brush to clean the blower wheel. • Reinstall the blower and tighten the four bolts securely. 6. Chimney • Frequency: As necessary / Yearly • By: Qualified Service Technician / Chimney Sweep The entire chimney should be professionally cleaned at least once yearly. It is best to have this done at the end of the heating season to be sure all ash is removed. You'll also want to inspect the condition of the chimney prior to using the appliance, to be sure there are no bird or animal nests. Save These Instructions 3-90-08560 Dry Seasoned Wood Only! 29 30 Dry Seasoned Wood Only! Power Cord Variable Speed Switch 3-90-08560 White Wire Grounded to housing Black Wire 10 Blower Thermostat TL2.0 / TL2.6 Optional Blower Kit #1-00-856002 - WIRING DIAGRAM TL2.0 Woodburning Stove Reference Materials Save These Instructions 1 2 TL2.0 service Parts Beginning Manufacturing date: sept 2011 Ending Manufacturing date: active Wood stove 1-90-856000-1 Black W/Pedestal 1 2 6 7 5 8 4 3 9 10 27 11 12 14 17 16 15 26 13 23 25 21 20 18 19 part number list on following page. 22 24 11/13 TL2.0 service Parts Beginning Manufacturing date: sept 2011 Ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide stocked at depot model number and serial number when requesting service parts from your dealer or distributor. ITEM 1 2 dEsCRIPTION COMMENTs 1-10-856509A Post 008840369 1-10-856009A Bottom Hinge Set of 2 1-00-856084 Hinge spacer Qty 2 req 2-00-40021L Top load door gasket 5 ft 1-00-10050 Wood Handle, Pkg of 3 Pre 008840369 3-40-08746-3 Top load door, painted w/gasket & hdwr Damper frame asy with damper 1-10-250109A Damper adjuster with hardware Damper gasket y y y 1-00-250153 30 ft Damper Only 3 PaRT NuMBER Pre 008840369 1-00-00888 y 1-10-249107 Damper Shaft Retainer & Hardware Set of 2 1-00-249145 y Gasket, 1" Single Ply Tape 10 Ft 1-00-88100 y 3-40-358110 y Pkg of 4 3-44-2500202-4 y Firedome Plus Combustion Package Gasket, brick air 4 Rear brick clips with hardware Pkg of 2 1-00-249135 5 Wooden handle for damper w/hardware Pkg of 2 1-00-00249 y 6 Damper handle, painted 3-50-00500S y 7 Damper Shaft bushing plates w/hardware 1-00-856061 y 8 Damper rod weldment 1-10-856011W y 9 Top Load Lift Arm w/Knob Post 008840369 1-10-08722 y 10 Lift Arm Wood Knob & Hdw 2 Sets 1-00-06228 11 Left side panel, painted 12 Inlet brick 3-40-358112 y 13 Brick Air Plate Set of 2 1-00-358118 y 14 Side & rear firebrick 6 pc set 1-00-856077 y 15 Ash grate 2-00-856013B y 16 Andiron with hardware and extensions 1-00-856010 y 17 Front load door asy, painted with glass 1-10-06920A Inner & outer 2-00-856023B Ball Spring Bracket 2-00-06714 Cast Door, Painted Door gasket y 4-00-06920P 30 ft Door latch, painted w/hdwr & handle 1-00-00888 y 1-00-249119 y Glass clips Set of 4 2-00-05202-4 y Glass gasket 15 ft 1-00-2312 y Glass only 3-40-06932 y Latch plate, roller & hardware 1-00-06903 Additonal service parts on following page TL2.0 service Parts Beginning Manufacturing date: sept 2011 Ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide stocked at depot model number and serial number when requesting service parts from your dealer or distributor. ITEM 18 dEsCRIPTION COMMENTs Ash door asy, painted with handle 1-10-856005A Ash door latch only Ash door gasket PaRT NuMBER 3-00-249149 5 ft 1-00-10000 Ash door hinge with hardware 1-00-856020 Ash door roller with hardware 1-00-06902 Ash Door Wood Handle Pkg of 3 y 3-40-08746-3 19 Air slide rod bracket with hardware 1-00-856008 y 20 Air control weldment 1-10-856004W y 21 Air slide 1-10-856003W y 22 Ash pan 1-10-856006A y 23 Combustion shoe brick 3-40-00100 y 3-44-06951 y 3-40-856086 y y Shoe brick gasket 24 Side brick insulation Qty 2 req 25 Right side panel, painted 2-00-856024B 26 Heat shield mounting plate, painted 2-00-856026B 27 Rear heat shield, painted with hardware 1-00-856025 Blower Blockoff 1-00-856019 Brick Retainers, Side Set of 2 1-00-06945 Cast Weld on Door Hinge Qty 2 req 3-00-773813 y y y Combustion Package Cap 2-00-358150B Distribution Blower 7000-537 Power Cord 3-20-06652 y Snap Disc Control 3-20-408412 y Touch up Paint Pre 008840396 3-42-1990 Post 008840396 3-42-19905 Ashlip Trim Brushed Stainless 3-43-4722386-7 Door Trim Brushed Stainless 3-43-856015-7 Tile Trim Brushed Stainless 3-43-06729-7 Spring Clips (Required for installation of Tile Frame) Additonal service parts on following page Pkg of 20 3-31-232547-20 TL2.0 service Parts Beginning Manufacturing date: sept 2011 Ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide stocked at depot model number and serial number when requesting service parts from your dealer or distributor. ITEM dEsCRIPTION COMMENTs PaRT NuMBER Hardware Packages #10-24 x 1/4" Alloy Steel Black Oxide Cup Point SSS Pkg of 100 3-30-2006-100 y Acorn Nut, 10-24 Nickel Plated Pkg of 50 3-30-8014-50 y Ball Plunger, 5/16 x 1/2 Pkg of 3 3-31-5500-3 y Bolt, Case Hardened Zinc Flange, 1/4-20 x 3/8 Pkg of 50 3-30-2000-50 y Bolt, HCS 3/8-16 x1 1/4 Pkg of 25 3-30-1135-25 y Bolt,1/4-20 x 1/2" Grade 8.2 Zinc SAE Flange Pkg of 50 3-30-2001-50 y Cap Screw, 1/4-20 x 1 1/2 Grade 8 Yellow Zinc Hex Head Pkg of 25 3-30-1119-25 y Cap Screw, 1/4-20 x 1/2 Grade 8 Yellow Zinc Hex Head Pkg of 50 3-30-1109-50 y Cap Screw, 1/4-20 x 3/4 Grade 8 Yellow Zinc Hex Head Pkg of 50 3-30-1113-50 y Cap Screw, 1/4-20 x 5/8 Grade 5 Zinc Hex Pkg of 100 3-30-1110-100 y Cap Screw, 5/16-18 x 1/2" Grade 5 Zinc Plated Hex Pkg of 50 3-30-1122-50 y Cap Screw,1/4-20 x 3/8" Grade 5 Zinc Hex Pkg of 25 3-30-1106-25 y Cap Screw,5/16"-18 x 3/4" Grade 8 Plain Finish Hex Pkg of 50 3-30-1126-50 y Dowel Pin, 3/16 x 2" Bright Finish Steel Pkg of 15 3-30-2005-15 y Lock Nut, 10-32 Grade A Zinc Plated Top Pkg of 100 3-30-8019-100 y Machine Screw, 1/4"-20 x 2 1/2" Phillips Round Head Zinc Pltd Pkg of 25 3-30-6007-25 y Machine Screw, 10-32 x 3/8" Phillips Round Head Zinc Plated Pkg of 100 3-30-6005-100 y Nut , Centerlock,1/4-20 Pkg of 50 3-30-8020-100 y Nut, Grade 5 Zinc Plated Finished Hex, 5/16"-18 Pkg of 100 3-30-8005-100 y Nut,1/4"-20 Zinc Plated Finished Hex Pkg of 100 3-30-8004-100 y Nut,1/4-20 Grade C Zinc Plated Top Lock Pkg of 50 3-30-8021-50 y Rivet, 1/8" Dia .032-.062" Grip Range AB4-1CLD Alum Pkg of 100 3-30-7900-100 y Screw, #10-24 x 3/8" Alloy Steel Black Oxide Button Head Cap Pkg of 100 3-30-3011-100 y Screw, 5/16"-18 x 3/8" Alloy Steel Black Oxide Knurled Point SSS Pkg of 25 3-30-2004-25 y Screw, BLK OX, HWH TCS 10-24X1/2 Pkg of 100 3-30-1101-100 y Screw, Hex Washer Slot T23 Zinc Thread Cutting ,1/4-20x5/8" Pkg of 50 3-30-1111-50 y Screw,1/4"-20 x 3/8" Alloy Steel Black Oxide Button Head Cap Pkg of 100 3-30-3014-100 y Washer, 5/16" Zinc Plated SAE Flat Pkg of 50 3-30-0205-50 y Manufactured by: HeartH & HoMe tecHnologies, inc. Model: tl2.0 u.s. enviroMental Protection agency Meets EPA particulate matter (smoke) control requirements for noncatalytic wood heaters built on or after July 1, 1990. sMoKe 0 8.5 grams Per Hour efficiency 50% 60% 70% 80% 90% 100% Wood heaters with higher efficiencies cost less to operate. Heat outPut 9,600 to 31,800 btu use this to choose the right size appliance for your needs. asK dealer for HelP. this wood heater will achieve low smoke output and high efficiency only if properly operated and maintained. see owner’s manual. #3-90-856 Hearth & Home Technologies LIMITEd LIfETIME WaRRaNTy Hearth & Home Technologies, on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer. WaRRaNTy COvERagE: HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered components manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period, HHT will, at its option, repair or replace the covered components. HHT, at its own discretion, may fully discharge all of its obligations under such warranties by replacing the product itself or refunding the verified purchase price of the product itself. The maximum amount recoverable under this warranty is limited to the purchase price of the product. This warranty is subject to conditions, exclusions and limitations as described below. WaRRaNTy PERIOd: Warranty coverage begins on the date of original purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent, authorized HHT dealer/ distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of product shipment from HHT, regardless of the installation or occupancy date. The warranty period for parts and labor for covered components is produced in the following table. The term “Limited Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage for gas appliances, and 10 years from the beginning date of warranty coverage for wood, pellet, and coal appliances. These time periods reflect the minimum expected useful lives of the designated components under normal operating conditions. Warranty Period Parts Labor 1 Year 2 years HHT Manufactured Appliances and Venting Gas X X Wood X X X 3 years Pellet EPA Wood Coal X X X X X X X X X Components Covered Electric Venting X X All parts and material except as covered by Conditions, Exclusions, and Limitations listed Igniters, electronic components, and glass Factory-installed blowers Molded refractory panels X Firepots and burnpots 5 years 1 year 7 years 3 years 10 years 1 year X Limited 3 years Lifetime X X X X X 90 Days X X X X X X X X Castings and baffles X X Manifold tubes, HHT chimney and termination Burners, logs and refractory Firebox and heat exchanger X X All replacement parts beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645F 02-18-13 Page 1 of 2 WaRRaNTy CONdITIONs: • • • • • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is available on the HHT branded websites. This warranty is only valid while the HHT appliance remains at the site of original installation. This warranty is only valid in the country in which the HHT authorized dealer or distributor that sold the appliance resides. Contact your installing dealer for warranty service. If the installing dealer is unable to provide necessary parts, contact the nearest HHT authorized dealer or supplier. Additional service fees may apply if you are seeking warranty service from a dealer other than the dealer from whom you originally purchased the product. Check with your dealer in advance for any costs to you when arranging a warranty call. Travel and shipping charges for parts are not covered by this warranty. warranty exClusions: This warranty does not cover the following: • Changes in surface finishes as a result of normal use. As a heating appliance, some changes in color of interior and exterior surface finishes may occur. This is not a flaw and is not covered under warranty. • Damage to printed, plated, or enameled surfaces caused by fingerprints, accidents, misuse, scratches, melted items, or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes. • Repair or replacement of parts that are subject to normal wear and tear during the warranty period. These parts include: paint, wood, pellet and coal gaskets, firebricks, grates, flame guides, batteries and the discoloration of glass. • Minor expansion, contraction, or movement of certain parts causing noise. These conditions are normal and complaints related to this noise are not covered by this warranty. • Damages resulting from: (1) failure to install, operate, or maintain the appliance in accordance with the installation instructions, operating instructions, and listing agent identification label furnished with the appliance; (2) failure to install the appliance in accordance with local building codes; (3) shipping or improper handling; (4) improper operation, abuse, misuse, continued operation with damaged, corroded or failed components, accident, or improperly/ incorrectly performed repairs; (5) environmental conditions, inadequate ventilation, negative pressure, or drafting caused by tightly sealed constructions, insufficient make-up air supply, or handling devices such as exhaust fans or forced air furnaces or other such causes; (6) use of fuels other than those specified in the operating instructions; (7) installation or use of components not supplied with the appliance or any other components not expressly authorized and approved by HHT; (8) modification of the appliance not expressly authorized and approved by HHT in writing; and/or (9) interruptions or fluctuations of electrical power supply to the appliance. • Non-HHT venting components, hearth components or other accessories used in conjunction with the appliance. • Any part of a pre-existing fireplace system in which an insert or a decorative gas appliance is installed. • HHT’s obligation under this warranty does not extend to the appliance’s capability to heat the desired space. Information is provided to assist the consumer and the dealer in selecting the proper appliance for the application. Consideration must be given to appliance location and configuration, environmental conditions, insulation and air tightness of the structure. This warranty is void if: • • • The appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals. Over-firing can be identified by, but not limited to, warped plates or tubes, rust colored cast iron, bubbling, cracking and discoloration of steel or enamel finishes. The appliance is subjected to prolonged periods of dampness or condensation. There is any damage to the appliance or other components due to water or weather damage which is the result of, but not limited to, improper chimney or venting installation. LIMITaTIONs Of LIaBILITy: • The owner’s exclusive remedy and HHT’s sole obligation under this warranty, under any other warranty, express or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above. In no event will HHT be liable for any incidental or consequential damages caused by defects in the appliance. Some states do not allow exclusions or limitation of incidental or consequential damages, so these limitations may not apply to you. This warranty gives you specific rights; you may also have other rights, which vary from state to state. EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645F 02-18-13 Page 2 of 2 TL2.0 Woodburning Stove Service & Maintenance Log Date Of Service Save These Instructions Performed By Description Of Service 3-90-08560 Dry Seasoned Wood Only! 38 At Harman, we build each product to a standard, not a price. This powerful heating appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels. (Signature of Boxer) Your premium quality hearth product designed and assembled by the experienced and skilled members at Harman in Halifax, PA, USA. Proudly Printed On 100% Recycled Paper
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Create Date : 2013:11:12 07:59:26-05:00 Creator : Adobe InDesign CS6 (Windows) Modify Date : 2013:11:15 07:05:21-06:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Instance ID : uuid:b0643158-ffe9-4131-92d6-08f746695c81 Original Document ID : adobe:docid:indd:c9465315-c4ac-11df-b34e-ccb71457ada2 Document ID : xmp.id:FD088D429A4BE31183D49A7227FA213F Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:3E1DC9409A4BE31183D49A7227FA213F Derived From Document ID : xmp.did:FEC9D94EF53BE31189F0E59EB8021420 Derived From Original Document ID: adobe:docid:indd:c9465315-c4ac-11df-b34e-ccb71457ada2 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2013:11:12 07:59:26-05:00 Metadata Date : 2013:11:15 07:05:21-06:00 Creator Tool : Adobe InDesign CS6 (Windows) Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 40EXIF Metadata provided by EXIF.tools