HeathCo 60WRC02TX 6002TX Remote Control Transmitter User Manual 598 1136 00

HeathCo LLC 6002TX Remote Control Transmitter 598 1136 00

Users Manual

DRAFT COPY© 2003 DESA Specialty Products™ 598-1145-00Multi-ChannelRemote ControlFeatures•Operational range of up to 100 feet.•Controls all Heath®/Zenith Remote Home™ products.•FCC/IC tested and approved.•Flash control on compatible receivers when using the Panicfeature.Battery CoverTwo AAABatteries (NotIncluded)Installing 2-AAA BatteriesALL ONALL OFFOFFDIMPANICABONGROUP(Dip Switch 4 inDOWN position)(Dip Switch 4 inUP position)1  2  31  2  31  2  31  2  31  2  31  2  31  2  31  2  3ABSetting Receiver(s) Dip SwitchesThe Control Panel transmitter haspreprogrammed dip switch settings for eachchannel. In order for the Control Panel tocommunicate with a receiver, the dipswitches on the receiver must correspondwith the preprogrammed dip switch settingsof the channel you wish to use. Note: Thereare no dip switches on the Control Panelthat require setting.1. Determine which receiver(s) will beoperated by which channel.2. Set receiver(s) dip switches 1, 2, and 3to match the dip switch settings for thechannel you wish to operate thereceiver(s).3. Determine whether the receiver(s) willbe in Group A or B.4. Set dip switch 4 on the receiver to thesame setting as Group A or B.Preprogrammed Dip SwitchSettings for Remote Control(Included on Back of Productas a Reference)Battery InstallationThe Multi-Channel Remote Control is de-signed for 3 Volt operation:1. Remove battery cover on rear of hous-ing by pushing clip and lifting up.2. Install  2-AAA batteries (not included)according to polarity markings.
2598-1145-00DRAFT COPYControl DescriptionsA or B GROUP: Allows eachchannel to be used for 2 dif-ferent groups of receivers (fora total of 16 channels). Tochoose Group A, press the“A” button (the Group “A” in-dicator will be on). To chooseGroup B, press the “B” but-ton (the Group “B” indicatorwill be on).Label Channels: Removeclear plastic film from chan-nel label guide by placing twofingers on the plastic and“pinching” the plastic. Re-move card. Use the decals(included) or write on the cardto label each channel. Re-place card and plastic film.ALL ON: Turns ON all lightfixtures programmed for ei-ther Group A or Group B. Either Group A or Group B LED indicator will light asunits are turned on. To perform this function, select either Group A or Group Bthen press ALL ON. If lights are off or dimmed (where applicable) they will beturned on full power.ALL OFF: Turns OFF all light fixtures programmed for either Group A or GroupB. Either Group A or Group B LED indicator will light as units are turned off. Toperform this function, select either Group A or Group B then press ALL OFF. Iflights are on or dimmed (where applicable) they will be turned off.PANIC: Turns ON all light fixtures programmed for either Group A or Group B.Light fixtures within the selected group that have Flash capability will FLASHwhen this command is received. Either Group A or Group B LED indicator willlight. ALL OFF will turn off all channels within the selected group and reset all lightfixtures to normal operating mode.Channel ON: Turns ON all light fixtures that are configured to work with aparticular channel. To perform this function, press the ON button after selectingthe channel number desired (between 1 and 8). When ON is pressed, the A orB LED will momentarily light.Channel OFF: Turns OFF all light fixtures that are configured to work with aparticular channel. To perform this function, press the OFF button after selectingthe channel number desired (between 1 and 8). When OFF is pressed, the A orB LED will momentarily light.ONALL ON ALL OFFDIMPANICABOFFChannelLabelGuideALL OFFALL ONGroup SelectionButtonsGroup SelectionLED IndicatorsGroup Selection
3598-1145-00DRAFT COPYChannel DIM: Dims all light fixtures that are equipped with the dimming featurethat are configured to work with a particular channel. To perform this function,press the DIM button located by the channel number desired (between 1 and 8).Pressing DIM repeatedly will toggle thru the different dim levels if the light fixtureis capable of more than one level of dim. Each time the DIM button is pressed,the channel LED will momentarily light.The receiver saves the last dim setting used. To recall the last dim setting, pressthe DIM channel once.Note: The receiver must be capable of dimming for the DIM button to workproperly.SpecificationsRange.......................................................................... Up to 100 feet (30.5 m)Rated Voltage (2-AAA Batteries) ..........................................................  3 VDCPOSSIBLE CAUSE1. Batteries installed incor-rectly.2. Batteries are dead.1. Dip switch settings on re-ceiver do not match con-troller.2. Wrong group or channel isselected.3. Signals from controller arebeing blocked, or transmit-ter is out of range.4. Batteries are weak.Troubleshooting GuideSYMPTOMRemote con-trol does notcome on.Remote con-trol will not op-erate receiver.Technical Service(Do Not Send Products)If you experience a problem, follow this guide. You may also want to visit our Website at: www.desatech.com. If the problem persists, call* for assistance at 1-800-858-8501, 7:30 AM to 4:30 PM CST (M-F). You may also write* to:DESA Specialty Products™P.O. Box 90004, Bowling Green, KY 42102-9004ATTN: Technical Service Specialty Products* If contacting Technical Service, please have the following information avail-able: Model Number, Date of Purchase, and Place of Purchase.No Service Parts Available for this ProductSOLUTION1. Install batteries accordingto polarity markings insideremote control.2. Replace batteries.1. Check dip switch settingson receiver.2. Verify correct group andchannel are selected.3. Check for metal objects thatcould block the signal, orreposition the transmitter.4. Replace batteries.
4598-1145-00DRAFT COPYTWO YEAR LIMITED WARRANTYThis is a “Limited Warranty” which gives you specific legal rights. You may also haveother rights which vary from state to state or province to province.For a period of two years from the date of purchase, any malfunction caused byfactory defective parts or workmanship will be corrected at no charge to you.Batteries are not covered. To obtain a refund or a replacement, return the productto the place of purchase.Not Covered - Repair service, adjustment and calibration due to misuse, abuse ornegligence, light bulbs and other expendable items are not covered by this warranty.Unauthorized service or modification of the product or of any furnished componentwill void this warranty in its entirety. This warranty does not include reimbursementfor inconvenience, installation, setup time, loss of use, or unauthorized service.This warranty covers only DESA Specialty Products™ assembled products and isnot extended to other equipment and components that a customer uses in conjunc-tion with our products.THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES,EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRESENTATION ORCONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FORANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALLSPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMERAND THERE SHALL BE NO LIABILITY ON THE PART OF DESA SPECIALTYPRODUCTS™ FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUEN-TIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS ORPROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do notallow the exclusion or limitation of incidental or consequential damages, so the abovelimitation or exclusion may not apply to you. Retain receipt for warranty claims.DESA Specialty Products™ reserves the right to discontinue products and tochange specifications at any time without incurring any obligation to incorporatenew features in products previously sold.Regulatory InformationThis device complies with Part 15 of the FCC Rules and RSS-210 of IndustryCanada. Operation is subject to the following two conditions: (1) this device maynot cause harmful interference, and (2) this device must accept any interferencereceived, including interference that may cause undesired operation.The term “IC:” before the radio certification number only signifies that IndustryCanada technical specifications were met.The user is cautioned that changes or modifications not expressly approved bythe party responsible for regulatory compliance could void the user’s authorityto operate the equipment.

Navigation menu