Heiman Technology HS1CGZ Smart Combustible Gas Sensor User Manual

Shenzhen Heiman Technology Co.,Ltd. Smart Combustible Gas Sensor

User Manual

1.Working Voltage: AC100V~240V2.Average Power Consumption: <1.5W3.Alarm Sound: 75dB/1m4.Alarm Density: 6%LEL±3%LEL(natural gas)5.Networking: Z-Wave Ad-hoc Networking6.Wireless Networking Distance: ≥70m (in open area)7.Working Environment: -10℃ ~  50℃8.Environment Humidity: Max 95% RH9.Dimension: 79*68*31mm ( )+no including plugPlease  click  the  add  button  (  +  ”  )    to  enter  gateway networking mode. “ SpecificationLight State Product TestingWarm PromptPower  on  the  sensor,  the  green  LED  will  be  lit  and  a  “beep”  sounded,the  sensor  enters  into  preheating  state.  At  this  time,  red  LED  andyellow  LED  flash  alternately.  The  flash  will  stop  3  minutes  later, which  indicates  that  the  sensor  is  in  normal  working  state.  (Don't  usegas to test sensor while  preheating).Please read the user manual carefully before operation.The guide picture is for reference only. Please in kind prevail.This  Smart  Combustible  Gas  Sensor  adopts  super  low power  consumption  Z-Wave  wireless  networking technology.  It  is  used  for  detecting  combustible  gas leakage  and preventing  harm caused  by  gas  leakage.  it also can be used as Z-Wave repeater to extend wireless communication  distance.  It  adopts  high  stability  semi-conductor  gas  sensor, with  high  stability,  little  sensitivity drift  and  may  other  features.  Sensor  alarms  while  gas density  in  air  exceed  alarm  level.  It  is  applicable  for kitchen or possible gas leakage in door areas.Factory Default: Long press networking hole for 10 seconds, then ID code will  be cleared and  the sensor   will be  reset to factory default.1.Shell surface will be slightly hot while working, which is a normal phenomenon .2.Please dismantle sensor while decorating house.3.Avoid spraying aerosol around sensor.4.Oil  contamination  around  gas  convection  holes  will effect  the  sensitivity  of  gas  sensor,  after  long  time using.Suggest users to clear gas convection holes with brush  mixing  little  detergent  every  3  months  (or depends  on  specific  oil  contamination  level). Avoidletting detergent enter sensor body. Please retest after cleaning.5.Semi-conductor of gas sensor supports 5-year lifespan. Please replace sensor timely.6.Please do not use lighter to test sensor directly in case of any damage to gas sensor inside.7.For  your  safety,  in  addition  to  use  sensor  properly, please  be  vigilant  and  enhance  safety  prevention awareness in daily life.State           Color                 Light                             Alarm Sound    Power MalfunctionConstantly LitConstantly LitNoneConstantly BuzzingTest button of this sensor is used for testing whether  LED indicator and buzzer can work properly. Red LED and yellow LED flash alternatively with buzzer alarming when test button pressed.Networking HoleLED IndicatorGas Convection HolesTest  Button        Factory DefaultPower On & PreheatingNetwork:  According  to  APP  prompting,  please  press networking  hole  for  3  times  in1.5  seconds,  then  green  LED will flash  quickly(the  longest  networking  time  is 30  seconds), APP interface will display icon, networking successfully.Disconnecting:  Please  click  delete  key  of  the  device,  then press networking hole for 3 times in 1.5 seconds, then green LED will flash slowly for 6 times, disconnecting successfully. FlashingAlarm "Di-Di” Alarm SoundNetworking Mode1 2 3456 7 8 9 10 11User ManualSmart Combustible Gas SensorAppearance InstructionProduct IntroductionFloorsensorGas stoveMax diameter 3mCeilingBefore installation,  pls confirm the  detecting  gas density, heavier or lighter than air. If detecting gas is heavier than air:  LPG.,  etc,  install  at  0.3-1m  height  from  floor,  semi-diameter to gas source less than 1.5m. If detecting gas is lighter  than  air:  natural  gas,  manufactured  gas,  marsh gas.,  etc,  install  at  0.3-1m  height  from  ceiling,  semi-diameter to gas source less than 1.5m.Functional Diagram可燃气体报警器红外探测器门磁探测器Emergency alarm treatment Fault analysis and troubleshootingThe detector will keep alarming while the natural gas or LPG density  in  air  exceeds  the  alarm  level.  Pls  do  relative treatments as below:1.Shut down the tube valve right away.2.Extinguish  all  fire  sources  and  do  not  use  anything  can make fire, e.g. lighters, matches., etc.3.Avoiding switches on various electric equipments.4.Open the window and make the air flow rapidly.1. Power on detector and      aging test for 24 hours; 2. F Do not test detectors     when warming up.Yellow LED keeps on andbuzzer keeps beepingContact dealer to repairSymptom Reason RemedyAlways warming up after power on(LED keeps flashing)1. Long time no power; 2. Test gas detector      when warming up.Gas sensor faultHS1CG-Z
  FCC Warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •  Reorient or relocate the receiving antenna. •  Increase the separation between the equipment and receiver. •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •  Consult the dealer or an experienced radio/TV technician for help.  Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment.  This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Navigation menu