1. Working Voltage: DC3V(CR123A lithium battery)
2. Static Current: ≤10uA
Networking Hole
3. Alarm Current: ≤60mA
Test/Hush Button
and LED Indicator
4. Networking: Z-Wave Ad-Hoc Networking
5. Sound Level: ≥85dB/3m
6. Distance Of Networking: ≥70m (open area)
Alarm
7. Working Temperature: -10°C ~ +50°C
8. Working Humidity: ≤95% RH
9. Dimension: 60×60×49.2mm
Tips
Technical Deta
Product Details
This product is a smart photoelectric smoke sensor,
with ultra-low-power Z-Wave wireless network
technology design. It is an warning device, cannot
sense gas, heat, or flame, cannot prevent or put out
fire.Real-time detecting the presence of smoke,
detection of visible particles(smoldering fire) faster
than ionization smoke alarms. Red LED flashes
rapidly and detectors sound alarm once detecting
smoke fire danger, it can alert you and your family
timely. Smoke alarms should be installed in all
rooms, living room, storage areas, basements and
atticsunit that fire may happen.
Product Introduction
User Manual
HS1SA-Z
1. This sensor is designed specifically for home use, may
not able to provide sufficient fire alert for public areas.
2. Please avoid installation in bathrooms and other very
humid places, dusty or greasy areas, or very airy place
with air conditioner, ceiling fans,etc.
3. Please keep sensor clean, and do not let dust
accumulated. It is recommended to be cleaned every
6 months with a household cleaner and a soft brush.
4. The effective lifespan is 10 years. Replacement every
10 years, regardless of sensors breakdown or not (
battery lifespan: 3 years).
5. Please pay attention if it alarms. Besides proper use of
sensor, we should also strengthen the consciousness
of fire safety.
Sloping ceiling mounting
If ceiling is sloping, please install the smoke sensor at
horizontal distance 90cm away from the ceiling top.
Dead air area
Bracket
Recommended and Avoided
Installation Position
Installation Step 3
Installation Step 4
OF
WIS
FT
T O
Alarm Sound
Red LED flashes every 53 seconds.
No
Testing
Red LED flashse quickly
Rapid beeps
Alarm
Red LED flashse quickly
Rapid beeps
Hush mode Red LED Flashes one time every 10 seconds.
No
Low Power Red LED flashes one time every 53 seconds.
one beep every
53 seconds
Fault
Please make sure there is no real fire danger when using
hush function. If non-emergency smoke(e.g. Steam)
causes nuisance alarms, please do not stop alarm by
block smoke detector or in other forms. You could press
the hush/test button to stop alarm temporarily.(Ten
minutes later, the smoke detector will be back to normal
working condition)
Form1
10
Hush Function
every
Red LED flashes two times every 53 seconds. two53beeps
seconds
please refer to the following situations, if the sensor can
not work normally:
1.Battery reaches service life (status refer to form 1).
Pleasereplace the battery.
2.Fault affected by dirt with dust or oil, etc (status refer to
Form 1). Please clean the alarm correctly.
3.Whether the alarm is properly rotated into the mounting
bracket.
Rotate the sensor anticlockwise to separate from
bracket, then remove battery insulating strip to electrify
the sensor.
Press and release the test button to test the alarm. The
alarm will sound loud short beeps. It means the smoke
detector can work normally. The alarm may stop sounding
once releasing the test button. It is suggested to test the
smoke alarm at least one time every week. Do not use an
open flame to test this smoke alarm.
11
Battery Replacement
” in the
Attach the sensor to the mounting bracket and turn
clockwise to lock into place. Remove the membrane of
double sided adhesive tape on the mounting bracket.
Light
Normal
Mute and Test
Status and Troubleshooting
Detector will enter the network mode by clicking “
APP.
Connecting network: According to APP prompt, press networking
hole for 2 seconds till green LED flash quickly, APP shows slip,
green LED keep on for 3 seconds, networking succeed.
Disconnecting network: Press the networking button for 5
seconds to disconnect the network, after the green light
flashes slowly for 3 seconds, which indicates network is
disconnected successfully.
Status
Sloping Ceiling
Mounting Position
T ON
Installation Step 2
TWIS
The illustrations in the manual are only for your reference, please in kind prevail.
OFF
*Please read the user's manual carefully before operation.
Installation Step 1
Installstion Renderings
Flat ceiling mounting
The preferred location to install smoke sensor is in the
centre of the ceiling, because smoke, heat and
combustible products rise to ceiling and will laterally
spread.Keep at least 30cm distance from lights or
decorations, and at least 15 cm away from walls and
corners.
Smart Smoke Sensor
Please replace battery correctly according to the positive
and negative electrode. Dispose of used battery in right
way. Pay attention to environmental protection.
12
Statement
*Instruction is for reference only, please prevail in kind.
*Because of the updating of the technology, the final
interpretation right owned by factory, if there are any
inconformities when using this products under this instruction.
13
FCC Warning:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of
the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications to this device not explicitly approved
by manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Creation Date--Text             : 
Producer                        : Corel PDF Engine Version 14.0.0.653
Mod Date--Text                  : 
Format                          : application/pdf
Creator                         : USER
Title                           : 601010839 HS1SA-Z智能烟雾报警器中性英文说明书.cdr
Creator Tool                    : CorelDRAW
Modify Date                     : 2017:04:26 11:59:42+08:00
Metadata Date                   : 2017:04:26 11:59:42+08:00
Document ID                     : uuid:38883dfd-0afb-4acf-8732-0b62c7ad6962
Instance ID                     : uuid:5d7e0db1-3d59-4804-925b-80dd0a6b8cbf
Page Count                      : 2
Create Date                     : D:20161130010924Z
Author                          : USER
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AK7XHS1SAZ

Navigation menu