Heiman Technology HS2SKZUS Smart Metering Plug User Manual

Shenzhen Heiman Technology Co.,Ltd. Smart Metering Plug

User Manual

子件代号:文件编号:物料名称:HS2SK-Z智能计量插座中性英文说明书2016-07-07邢江涛制作要求:1、制作尺寸:330*55mm2、六折扇形折页折法,折叠后尺寸为55*55mm3、120g铜版纸彩色印刷Smart M Plug Quick Operation Guideetering Technical ParametersProduct DescriptionProduct Details1.Working Voltage: AC100V~240V (full voltage range)2.Average Power Consumption: <0.5W3.Maximum Load: 3000W4. Metering Voltage Range: 100VAC-240VAC5.Metering Current Range:<16A6.Metering Power Range: <3000W7. Wireless Networking Distance: Up to 100 meters                                                      (in open area )8. Working Environment: -10℃ ~ +50℃9. Working Humidity:   95%RH10. Networking : Z-Wave Network11. Dimensions: 79.6*67.9*72mm ≤1 2 3 4Supply HubLED IndicatorPower Switch/Networking ButtonPlease click the add button (“+”) of APP  to enter gateway networking mode. 5Networking:  According  to  APP  prompting,  please  press power on/off button  of  smart  meter   for 3 times in 1.5 seconds,  then  blue  LED  will  flash  quickly  (the  longest networking time is 30 seconds), APP interface will indicate networking success.  plug*Please read the user manual carefully before operation.The guide picture is for reference only, please in kind prevail.This  is  a  smart  m ,  adopts  flame retardant  housing  shell,  and  super  low  power consumption  Z-Wave  wireless  transmission technology. ,  voltage,  current  overload  protection. ug  and  play,  easy  to  install.  ug  and  play, easy to install.etering  plugpower  meteringIt can be used as Z-Wave wireless repeater,  to  extend  wireless  communication distance.  It  supports    and timing  switch  functions. With  the  function  of powerPl PlDelete sub deviceDescription of LED Indicator StatusBlue LEDFlash quickly when networkingFlash slowly  when disconnecting State Light Light on when   is turned onplug    6 7Disconnecting:  Please  click  delete  button  of  the  device  in APP, then press power on/off button of smart metering   for  3  times  in  1.5  seconds,  blue  LED  will  flash  slowly  for 6 times, APP interface will indicate disconnecting success. plugFactory  :  Long  press  power  on/off  button  for  10 seconds, then ID code will be cleared and smart metering   will be reset.Resetplug       Factory ResetLight off  when   is turned off plug8 9Statement*Instruction is for reference only, please prevail in kind.*Because of the updating of the technology, the final   interpretation right owned by factory, if there are any   inconformities when using this products under this instruction.Power  on/off:  After  pressing  p , blue  LED  keeps  on  and  supply  hub  will  be  powered  on; Press power switch/networking  buttonower switch/networking button  again, blue LED turned off,supply hub will be powered off. 55mm 55mm55mm 55mm 55mm 55mm55mm55mmNetworkingChooseable PlugsThe APP  interface will show  the  power  of the  appliance  and record the power consumption after appliance is plugged into the smart  .plugPlease choose proper plug typeaccording to your need.!US Standard Smart   Plug UK Standard Smart   Plug10 11It is suit to work with table lamp, TV,  air-conditioner,  refrigerator,electric  fan,  coffee  machine,bread machine and some otherhousehold  appliances  and metering power consumption.601010955M417-11Ever1.0HS2SK-Z-USFCC Warning:This equipment has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to part 15 of the FCC Rules. These limits are designed to providereasonable protection against harmful interference in a residential installation. Thisequipment generates, uses and can radiate radio frequency energy and, if notinstalled and used in accordance with the instructions, may cause harmful interferenceto radio communications. However, there is no guarantee that interference will notoccur in a particular installation. If this equipment does cause harmful interferenceto radio or television reception, which can be determined by turning theequipment off and on, the user is encouraged to try to correct the interferenceby one or more of the following measures:o Reorient or relocate the receiving antenna.o Increase the separation between the equipment and receiver.o Connect the equipment into an outlet on a circuit different from that to whichthe receiver is connected.o Consult the dealer or an experienced radio/TV technician for help.Caution: Any changes or modifications to this device not explicitly approved bymanufacturer could void your authority to operate this equipment.This device complies with part 15 of the FCC Rules. Operation is subject to thefollowing two conditions: (1) This device may not cause harmful interference, and(2) this device must accept any interference received, including interference thatmay cause undesired operation.To comply with FCC RF exposure compliance requirements,this grantis applicable to only mobile configurations. The antennas used for thistransmittermust be installed to provide a separation distance of at least 20 cmfrom allpersons and must not be co-located or operating in conjunction with anyotherantenna or transmitter.

Navigation menu