Hewlett Packard Enterprise WA2620XAGNP Wireless LAN access Point User Manual Installation Manual

Hewlett-Packard Company Wireless LAN access Point Installation Manual

User Manual

  H3C WA2620X-AGNP Access Point Installation Guide                          Hangzhou H3C Technologies Co., Ltd.  http://www.h3c.com  Document version: APW100-20110330
i Contents Product overview ···················································································································1Overview ································································································································1Hardware specifications ···········································································································1LEDs ·································································································································2Ports·································································································································3Preparing for installation ··········································································································6Preparing installation tools ········································································································6Examining the installation site ····································································································6Installation site selection·····································································································6Temperature and humidity ·································································································6Power supply ····················································································································7Grounding and lightning protection ····················································································7Examining the AP ·····················································································································8Installing the AP ······················································································································9Installing the AP ·······················································································································9Installing the outdoor antennas ······························································································· 12Installing a directional antenna on a pole·········································································· 13Connecting cables ················································································································ 14Connecting the antenna cables······················································································· 15Connecting the Ethernet cable ························································································ 15Connecting the fiber cable ······························································································ 18Connecting the AP to the power source············································································ 19Connecting the grounding cable ····················································································· 19Verifying the installation·········································································································· 20Powering on the AP················································································································ 20Logging in to the AP·············································································································· 21Appendix A Crimping an RJ-45 connector ·············································································· 22
 1 Product overview Overview H3C WA2620X-AGNP access point (AP) is a new-generation AP that supports 802.11n and can work in fit or fat mode. A fit AP can work with an access controller (AC) or wireless switch to provide WLAN access. A fat AP can provide WLAN access alone. Figure 1 shows a typical networking scenario for WA2620X-AGNP APs. Figure 1 Deployment of WA2620X-AGNP APs (in fat mode) WA2620X-AGNPCore equipment room RADIUS serverWLAN management systemService database serverSwitchSwitchSwitchSwitchResidential communitySeaport or pierParking lotPCPCPCWA2620X-AGNPWA2620X-AGNP  Hardware specifications  The WA2620X-AGNP AP offers IP66 rated protection and allows for outdoor deployment. The following sections describe its hardware specifications, LEDs, and ports.  Table 1 Hardware specifications Item Description Dimensions (H×W×D)  76 x 245 x 245 mm (2.99 x 9.65 x 9.65 in.) Weight   2.35 kg (5.18 lb) Power consumption  12 W (standby) to 24 W (maximum) Protocols and materials • IEEE802.11a/b/g/n  • Waterproof cast aluminum + plastic housing 802.at  Support for PoE+
 2 LEDs Figure 2 WA2620X-AGNP LEDs    Table 2 LED description  LED Color Quantity Description POWER (Power LED)  Green 1 Indicates power status: • On: The AP is powered on. • Off: The AP is powered off or operates abnormally. ETH1 (10/100M) (10/100M Ethernet port LED) Green 1 Indicates Ethernet port status: • Steady on: A link is present on the port. • Off: No link is present on the port. • Blinking: The port is transmitting or receiving data. ETH1 (1000M) (GE port LED)  Green 1 Indicates Ethernet port status: • Steady on: A link is present on the port. • Off: No link is present on the port. • Blinking: The port is transmitting or receiving data. ETH2 (SFP) (GE fiber port LED)  Green 1 Indicates fiber port status: • Steady on: A link is present on the port. • Off: No link is present on the port. • Blinking: The port is transmitting or receiving
 3 LED Color Quantity Description data. 2.4G (802.11g/n LED)  Green  1 Indicates wireless link status: • Off: The wireless link is down or fails. • Slow blinking: The wireless link is normal. • Fast blinking: Data is being transmitted or received.  5G (802.11a/n LED)  Green  1 Indicates wireless link status: • Off: The wireless link is down or fails. • Slow blinking: The wireless link is normal. • Fast blinking: Data is being transmitted or received.  Ports  The WA2620X-AGNP AP provides three 2.4 GHz antenna ports and three 5.0 GHz antenna ports, a console port, Ethernet ports (fiber and copper), a power port, and a grounding terminal.
 4 Figure 3 WA2620X-AGNP port layout  1: 2.4G-1 antenna port   2: 2.4G-2 antenna port  3: 2.4G-3 antenna port 4: 5G-1 antenna port  5: 5G-2 antenna port  6: 5G-3 antenna port 7: ETH2 (1000BASE-FX fiber port)  8: ETH 1 (10/100/1000BASE-TX copper port) 9: Grounding terminal  10: Console port  Table 3 Port description  Port  Standards and protocols Function ETH 2  1000BASE-FX fiber port IEEE802.3 SFP MSA SFF-8472 Connects to the Internet or Metropolitan Area Network (MAN).  NOTE: The SFP transceiver module (9/125µm single mode fiber) uses an LC connector and delivers a transmission speed of 1250 Mbps (central wavelength: 1310 nm; output power: –9.5 dBm to –3 dBm; receive sensitivity ≤ –20 dBm; light saturation: –3 dBm).
 5 Port  Standards and protocols Function ETH 1 10/100/1000BASE-TX copper port  IEEE802.3 IEEE802.3u IEEE802.3at Connects to the Internet or MAN and serves as a PoE port. 2.4G-1/2/3 IEEE802.11b/g/n Antenna port for 2.4 GHz band 5G-1/2/3  IEEE802.11a/n  Antenna port for 5 GHz band CONSOLE  RS/EIA-232  Console port for configuration and management
 6 Preparing for installation This chapter describes how to prepare for the installation of the AP, including the preparation of tools and installation site survey.  Preparing installation tools When installing the AP, you may need the tools listed in Table 4. Choose the appropriate tools according to the installation environment.  Table 4 List of installation tools Type of tools  Tools General tools  Digging tools, adjustable wrench, pliers, Phillips screwdriver  Special tools  Cable stripper, crimping pliers, RJ-45 crimping pliers, waterproof sealing tape, fiber fusion splicer  Auxiliary tools  Ladder  Examining the installation site Before installation, examine the installation site to make sure that the AP will work in a good environment. You can examine the installation site from the following two aspects. Installation site selection  Keep the AP away from high temperature, dust, harmful gases, inflammables, explosive substances, electromagnetic interference sources (heavy-duty radars, radio stations, or electrical substations), unstable voltage, heavy vibration, or loud noise. The installation site should be dry, without any leakage, dripping, or dew. The AP should be at least 500 m (0.31 miles) away from the seaside and should not face the direction of sea wind. In engineering design, the site should be selected according to the network planning and technical requirements of the communications equipment, and the considerations such as climate, hydrology, geology, earthquake, electric power, and transportation. Temperature and humidity  Table 5 Temperature and humidity requirements  Item Range Operating temperature  –40°C to +65°C (–40°F to 149°F) Storage temperature  –40°C to +85°C (–40°F to 185°F) Operating relative humidity (noncondensing)  0% to 100% Storage relative humidity (noncondensing)  0% to 100%
 7 Power supply  The AP can be powered by a power injector or through PoE+. 1. Power injector You can use an H3C POE-5 power injector to power the AP. For more information about how to power the AP through the power injector, see “Connecting the AP to a power injector.”   NOTE:  The input voltage of the POE-5 power injector must be 85 to 264 VAC (50/60 Hz). The powerinjector is not shipped with the AP and must be ordered separately.   2. PoE+ If the switch connected to the AP is PoE+ capable, the AP can be powered by the switch through the cable between the 10/100/1000BASE-TX port of the AP and the Ethernet port of the switch.  Grounding and lightning protection  Table 6 Grounding and lightning protection requirements  Item Requirements  Grounding resistance  • The grounding resistance is usually required to be less than 5 ohms, and less than 10 ohms in an area with less than 20 thunderstorm days a year. If a piece of angle steel is buried as the grounding conductor, the grounding resistance is required to be less than 10 ohms. In an area with a higher grounding resistance, reduce the grounding resistance by using brine or resistance reducing agent around the grounding conductor. • The top of the grounding conductor should be at least 0.7 m (2.30 ft) away from the ground surface. In cold areas, the grounding conductor should be buried below the frozen soil layer. Grounding connection  • If a grounding strip is available, connect the yellow and green grounding cable of the AP to the grounding strip. To make a grounding cable, make sure the cable is with a cross-section area of at least 6 mm2 (0.01 in.2) and a length of no longer than 3 m (9.84 ft). • If no grounding strip is available, bury a piece of angle steel/steel tube at least 0.5 m (1.64 ft) long in the earth to serve as the grounding conductor. In the case of a piece of angle steel, the size should be at least 50 × 50 × 5 mm (1.97. × 1.97 × 0.20 in.); in the case of a piece of steel tube, it must be zinc-plated and have a wall thickness of at least 3.5 mm (0.14 in.). Weld the yellow and green grounding cable of the AP onto the grounding conductor and use anti-erosion treatment on the welding joint. The grounding cable should be as short as possible and must not be coiled. • Make sure that the grounding terminals of all the lightning arresters of the AP and the peer device of the AP are well grounded. Grounding lead-in A grounding lead-in is a metal conductor connecting a grounding net and a grounding strip. The grounding cable of the AP should be connected to the grounding strip. The grounding lead-in must be 30 m (98.43 ft) or shorter. A piece of zinc-coated flat steel with a cross-section area of 40 × 4 mm (1.57 × 0.16 in.) or 50 × 5 mm (1.97 × 0.20 in.) is recommended. Connect the grounding strip and the grounding lead-in of the AP through the yellow and green grounding cable with an area of 35 mm2 (0.05 in.2), or weld them directly. Use anti-erosion treatment on the welding joint.
 8 Item Requirements  Power grounding (AC) • Use a power cord with a protective earth (PE). Do not use a power cord with only an L line and an N line. • The neutral line of the power cord should not be connected with the PGND of other communications equipment. The L and N lines cannot be connected. Lightning rod In plain areas, the shielding angle of the lightning rod should be less than 45 degrees. In mountainous areas or lightning areas, the shielding angle should be less than 30 degrees. The lightning protection grounding (for example, the grounding of the lightning rod) should be connected to the grounding conductor of the equipment room. Antenna • The antenna support is already prepared according to the design requirements. • The AP is well grounded according to design requirements.  Network cable  Use a shielded twisted pair cable for outdoor installation. Make sure that the devices at the two ends of the cable are well grounded.  Examining the AP Before installing the AP, connect the AP to the power source (if a power injector is used) and the Ethernet and check the status of the LEDs to ensure that the AP is functional. Save the MAC address of the AP for future use.
 9 Installing the AP The WA2620X-AGNP AP can be mounted on a pole. To ensure the radio coverage, have the AP installed by professionals. The installation involves the following procedures:  Installing the AP Installing the outdoor antennas Connecting cables Verifying the installation Powering on the AP Installing the AP The AP can be fixed to a vertical or horizontal pole whose outer diameter is between 60 mm and 110 mm (2.36 in. and 4.33 in.). The mounting kit includes a pair of V-shaped brackets, a mounting plate, bolts, and nuts, as shown in Figure 4. Figure 4 Mounting plate and V-shaped bracket  1: Mounting plate  2:  Mounting  slot  (allows  bracket rotation) 3: Bolt  4: V-shaped bracket  You can adjust the tilt of the AP by rotating the mounting plate around the bolt to help installation, as shown in Figure 5.
 10 Figure 5 Adjust the tilt of the AP  1: Mounting plate  2: Bolt  3: Mounting slot (allows bracket rotation)  4: V-shaped bracket  Pole mounting is suitable for rooftop installation. Follow these steps to install the AP on a pole: Step1 Vertically fix the pedestal of the pole to the rooftop or a cement pier on the rooftop with expansion screws, as shown in Figure 6. Figure 6 Pole and pedestal    Step2 Fix the V-shaped bracket onto the mounting plate with the bolt. Step3 Attach another V-shaped bracket to the pole, making sure that the two V-shaped bracket are level. Insert two long bolts through the screw holes on the two brackets and attach the bolts, nuts, and flat and spring washers, as shown in Figure 7 and Figure 8.
 11 Figure 7 Mount the AP on the pole (vertical)  1: AP  2: Screw (M6 x 12)  3: Mounting plate  4: V-shaped bracket 5: Long bolt  6: #10 flat washer   7: #10 spring washer  8: M10 nut
 12 Figure 8 Mount the AP on the pole (horizontal)   1: AP  2: Mounting plate  3: V-shaped bracket  4: Long bolt 5: M10 nut  6: #10 spring washer  7: #10 flat washer  8: Screw (M6 x 12)  Step4 Fix the AP onto the mounting plate with screws and fasten the screws, as shown in Figure 7 and Figure 8.   NOTE:  You can fix the mounting plate on the pole with brackets before or after fixing the AP ontothe mounting plate, whichever is more convenient.   Installing the outdoor antennas
 13 Installing a directional antenna on a pole   NOTE:  Ensure that the location of the pole does not hamper the adjustment of antenna directionand tilt.   Before you install a directional antenna on the pole, make sure that the pole is vertical to the rooftop surface. Follow these steps to install a directional antenna: Step1 Weld the lightning rod to the tip of the pole.  Step2 Install the pole on a parapet or cement pier.  • If there are parapets on the rooftop and the height of the parapets is no less than 1.2 m (3.94 ft), you can fix the pole on a parapet with expansion screws and fix the directional antenna on the pole with the pole mounting bracket, as shown in Figure 9. Figure 9 Install a directional antenna on a parapet (I) Lightning rodDirectional outdoor antenna PoleParapetPole mounting bracket0.5 m1.2 mFlat steel barTo the grounding grid   • If there are parapets on the rooftop and the height of the parapets is less than 1.2 m (3.94 ft), you can fix the pole on a parapet at one point with expansion screws and fix the bottom end of the pole to the rooftop surface, and then fix the directional antenna on the pole with the pole mounting bracket, as shown in Figure 10.
 14 Figure 10 Install a directional antenna on a parapet (II)   • If there is no parapet on the rooftop, fix the pole to the rooftop surface or a cement pier on the rooftop with expansion screws and stabilize the pole with steel wires. Then, install the directional antenna on the pole, as shown in Figure 11. Figure 11 Install a directional antenna on a cement pier Cement pierSteel wirePoleDirectional outdoor antennaLightning rodPole mounting bracketFlat steel barTo the grounding gridSteel wire  Step3 Connect the pole to a grounding grid with a flat steel bar (40 x 4 mm or 1.57 x 0.16 in.).  Step4 Fix the antenna on the pole with the pole mounting bracket.  Connecting cables
 15  WARNING!  Before connecting any cable, make sure that all power lines are disconnected and locked out and that no hazardous voltage is present on the neutral (N) line.    CAUTION:  Make sure that the outer sheath of cables is intact and does not absorb moisture to protect the AP from water leak.  External cables may include antenna cable, Ethernet cable, fiber cable, grounding cable, and power cord.  Connecting the antenna cables  The antenna cables connect the antenna ports (2.4 GHz and 5 GHz) to the outdoor antennas. Follow these steps to connect the antenna cables:  Step1 Connect the antenna cables to the antenna ports of the AP at one end and to the outdoor antennas at the other end.  • For 2 x 2 MIMO antennas, connect the cables to the 2.4 G-1/3 and 5G-1/3 antenna ports on the AP. • For 3 x 3 MIMO antennas, connect the cables to the 2.4 G-1/2/3 and 5G-1/2/3 antenna ports on the AP, respectively. Step2 Wrap the connections with insulating tape and apply several layers of waterproof sealing tape over the insulating tape.    NOTE:  • No antenna arrestor is needed. The WA2620X-AGNP AP provides lightning arresting function.  • Make sure that the grounding cables are well grounded during outdoor deployment.  • You have the option to order the standard ready-made antenna cables, or order cables of desired lengths and N-type antenna connectors and make antenna cables on-site as needed.  • Stretch the waterproof sealing tape till the width of the tape is reduced to 3/4 of the original width and wrap the waterproof sealing tape around the cable to achieve desired waterproof performance.   Connecting the Ethernet cable    CAUTION:  Observe the following procedure when connecting the copper cable. Otherwise, the AP might be damaged.  Step1 Route the Ethernet cable with waterproof sheath from the equipment room to the AP.
 16 Figure 12 Connect a copper cable   Figure 13 Connect a fiber cable
 17 Figure 14 Power injector  Green normalDark failurePower inData inPower&data out   NOTE:  • If the AP is powered by a PoE+ switch, no power injector is needed. Make sure that the PoE+ switch can support the maximum power consumption of the AP. • If a fiber cable is used to transmit data, the copper cable only provides power and does not transmit data.  • The Ethernet port marked with “Signal & power output” on the power injector must be connected to the AP. • Make sure that the installation of the AP is complete before powering on the AP, regardless of whether the AP is powered through PoE+ or by a power injector.   Step2 Insert the copper cable through the liquid tight adapter and crimp an RJ-45 connector on the end of the cable. For more information about how to crimp an RJ-45 connector on a cable ,see “Appendix A Crimping an RJ-45 connector”. Step3 Connect the cable to the copper port of the AP.  Figure 15 Connect the copper cable to the copper port of the AP 123 1: RJ-45 connector  2: Liquid tight adapter  3: Sealing nut  Step4 Make sure the sealing nut is loose. Tighten the liquid tight adapter, and then tighten the sealing nut.  Step5 Seal the connection with waterproof sealing tape.
 18 Connecting the fiber cable    CAUTION:  • Observe the following procedure when connecting the fiber cable. Otherwise, the AP might be damaged.  • When a fiber cable is used to transmit data, both ends of the cable must use appropriate SFP transceiver modules. The SFP transceiver modules provided by H3C meet the outdoor deployment requirements, use single mode fiber, and have a transmission distance of 15 km (9.32 mi).   If the AP is connected to the switch through a fiber cable, an SFP transceiver module and a liquid tight adapter are required at the AP side, as shown in Figure 16. Figure 16 Connect the fiber cable to the fiber port of the AP  1: SFP transceiver module  2: Fiber connector   3: Liquid tight adapter  4: Sealing nut  Follow these steps to connect a fiber cable: Step1 Insert an SFP transceiver module into the fiber port of the AP.  Step2 Insert an LC fiber connector with liquid tight adapter to the SFP transceiver module.  Step3 Make sure the sealing nut is loose. Tighten the liquid tight adapter, and then tighten the sealing nut. Step4 Seal the connection with waterproof sealing tape.
 19  NOTE:  • The optional fiber cable is a 10-meter pigtail with waterproof sheath. One end of the pigtail uses an LC connector and a liquid tight adapter and is inserted into the fiber portof the AP and the other end uses an SC connector and is connected to an end user terminal or switch.  • If the fiber is connected to a fiber termination box, connect the SC connector to a pair of SC sockets. The one marked as A is the receiving port (RX) of the AP and must be connected to the transmitting port (TX) of the peer device; the one marked as B is the TX port of the AP and must be connected to the RX port of the peer device. Usually, fiber termination boxes are not waterproof. Put the fiber termination box indoor or in a waterproof cabinet.  • If the fiber is connected to a fiber connector box, cut off the SC connector and splice the fiber end with the connector on the connector box. The pigtail marked as A is connected to the RX port of the AP and the TX port of the peer device; the pigtail marked as B is connected to the TX port of the AP and the RX port of the peer device. Fiber connector boxes are usually waterproof and can be buried underground or mounted on a pole.   Connecting the AP to the power source  The WA2620X-AGNP AP can be powered by a power injector or a PoE+ switch. Connecting the AP to a power injector  As shown in Figure 14, follow these steps to connect the power injector to the AP: Step1 Connect the power input line to an AC power source. Step2 Connect the signal & power output line to the copper port of the AP. Step3 Connect the signal input line to a switch or an access controller.  Step4 Ground the PE output line of the power injector.  Connecting the AP to a PoE+ capable switch  To power the AP by using a PoE+ capable switch, connect the 10/100/1000BASE-TX port of the AP to an Ethernet port of the switch through an Ethernet cable.    NOTE:  • If the AP is powered by a PoE+ switch, the power injector is not needed. Make sure thatthe PoE+ port can support the maximum power consumption of the AP. • If the AP is powered by a power injector, put the power injector at the switch side, and the switch connected to the power injector does not need to be PoE+ capable.  • Make sure that the installation of the AP is complete before powering on the AP, regardless of whether the AP is powered through PoE+ or by a power injector.   Connecting the grounding cable Connect the grounding terminal of the AP to the grounding point with the yellow and green grounding cable shipped with the AP, as shown in Figure 3. For more information about the procedure, see “Grounding and lightning protection”.
 20  NOTE:  If the AP is powered by a power injector, the PE output line of the power injector must alsobe grounded.  Verifying the installation After the installation and cabling, check the following items before powering on the AP: • The power source meets the power specification of the AP; • The AP is well grounded; • The power input cable and the Ethernet cables are correctly connected; • The outdoor antennas are installed;  • If the AP is powered by a PoE+ switch, an Ethernet lightning arrestor (which is not shipped with the AP) is installed on the AP.  Powering on the AP Make sure that all the cables are correctly connected. Then, switch on the external power source and check the power LED of the AP against Table 2.    CAUTION:  If the AP is installed outdoor, the Ethernet cable must be waterproof and the connection at the AP port must be sealed with waterproof sealing tape.
 21 Logging in to the AP   NOTE:  A fit AP is zero-configuration and is managed by an access controller or wireless switch. Thischapter describes how to log in to a fat AP on a web interface.   Use the following factory default settings to log in to a fat AP on a web interface: • Username: admin • Password: h3capadmin • IP address: 192.168.0.50 (mask: 255.255.255.0) Follow these steps to log in to the AP: Step1 Connect the AP to a computer with an Ethernet cable.  Step2 Set the IP address of the computer to an address (such as 192.168.0.100 with a mask of 255.255.255.0) that is in the same subnet as the AP.  Step3 Launch the web browser and input the address (http://192.168.0.50) of the AP in the address bar and press Enter. The login interface appears, as shown in Figure 17. On the web interface, enter the default username and password and the verification code, and click Login.  Figure 17 Web interface
 22 Appendix A Crimping an RJ-45 connector You must insert the Ethernet cable through the liquid tight adapter before crimping an RJ-45 connector on the end of the cable (usually category 5 or category 5E cable). Figure 18 RJ-45 connector    The following describes two common types of cables and how to make them. • Straight-through cable: The colored wires are of the same sequence at the two ends of the cable. A straight-through cable is usually used to connect these devices: PC to hub or switch, router to hub or switch.  • Crossover cable: The colored wires are of different sequences at the two ends of the cable. A crossover cable is usually used to connect these devices: PC to PC, router to router, or PC to router.  Table 7 Straight-through cable pin-outs RJ45 pin  Signal  Wire  Signal direction  RJ45 pin 1 TX+ White-orange Æ 1 2 TX- Orange Æ 2 3 RX+ White-green Å 3 4 -  Blue -  4 5 -  White-blue -  5 6 RX- Green Å 6 7 -  White-brown -  7 8 -  Brown -  8  Table 8 Crossover cable pin-outs RJ45 pin  Signal  Wire  Signal direction  RJ45 pin 1 TX+ White-orange Æ 3
 23 RJ45 pin  Signal  Wire  Signal direction  RJ45 pin 2 TX- Orange Æ 6 3 RX+ White-green Å 1 4 -  Blue -  4 5 -  White-blue -  5 6 RX- Green Å 2 7 -  White-brown -  7 8 -  Brown -  8   NOTE:  • The Ethernet ports of the AP are autosensing and can recognize both types of cables.  • When making a cable, follow the exact sequence listed in Table 7 or Table 8. • When the AP is installed outdoors, the cable must be waterproof. If possible, use waterproof tubing to protect the cable.
Compliance and Safety Manual
i Contents  Safety Information Sicherheits informationen 安全信息 1Conventions Used Symbole Erläuterung 应用惯例 1Important Safety Information/Wichtige Sicherheitshinweise/重要安全信息 2Electricity Safety Elektrische Sicherheit 用电安全 3Regulatory Compliance Information  5Regulatory compliance standards (标题 2) 5Support Antennas & Accessories information  6EU Compliance information  6CE Marking  6EU Country Restriction in 2.4GHz band  9EU Country Restriction in 5GHz band  10WEEE Directive–2002/96/EC  11USA regulatory compliance  11FCC Part 15  11Canada regulatory compliance  13ICES-003 13RF Compliance  13Brazil RF Compliance  14Korea RF Compliance  14Taiwan regulatory statement  15
ii List of Tables Table 1 Safety symbol and description............................................................ 1Table 2 Regulatory compliance standards...................................................... 5Table 3 Authorized Antennas & Accessories................................................. 6Table 4 Equipment may be operated in the following country: ............ 6Table 5 R&TTE declaration statements:........................................................... 7Table 6 Europe-Restrictions for Use of 5GHz Frequencies in European Community Countries.................................................................................10
 1 Safety Information Sicherheits informationen 安全信息 Conventions Used Symbole Erläuterung 应用惯例 The symbols in this manual are shown in the following table. They are used to remind the reader of the safety precautions during equipment installation and maintenance. Die Symbole in diesem Handbuch verwendeten sind in der folgenden Tabelle dargestellt. Diese Symbole sollen das Personal während der Installation und Instandhaltung der Ausrüstung an die Wichtigkeit der im Handbuch aufgeführten Sicherheitsvorschriften erinnern. 以下表格中的安全标识,是用来提示读者在进行设备安装和维护时的安全预防要求。 Table 1  Safety symbol and description  Sicherheitssymbole und Beschreibung 安全标识和描述 Safety Symbol Symbole 安全标识 Description Erläuterung 描述  Generic alarm symbol: To suggest a general safety concern Alarm: Hinweis auf ein generelles Sicherheitsproblem 一般注意标识:用于一般安全提示  ESD protection symbol: To suggest electrostatic-sensitive equipment. ESD-Schutz: Hinweis auf Beschädigung infolge elektrostatischer Entladung 防静电标识:用于表示静电敏感的设备  Electric shock symbol: To suggest a danger of high voltage
 2 Safety Symbol Symbole 安全标识 Description Erläuterung 描述 Elektrischer Schlag: Hinweis auf Gefährdung durch Hochspannung 电击防护标识:用于表示高压危险  Important Safety Information/Wichtige Sicherheitshinweise/重要安全信息  Caution: You must read all of the installation instructions in the Installation Guide supplied with your equipment and the following safety instructions before installation or operation. Achtung: Sie müssen vor der Installation oder Bedienung das mit Ihrer Anlage mitgelieferten Installationshandbuch und die folgende Sicherheitshinweise lesen. 注意:在安装和操作本设备时,务必阅读设备安装手册的内容,以及下文的所有安全说明。  Caution: Do not block ventilation openings while the system is on, and keep at least 5 cm distance from ventilation openings and walls or other things which may block the openings. Achtung: Blockieren Sie die Lüftungsmündungen nicht, wenn das System läuft. Stellen Sie die Lüftungsmündungen mindestens 5 cm entfernt von der Wände oder anderen Sachen, die die Mündungen blockieren können. 注意:设备在工作时必须确保通风口的畅通,确保设备离墙壁或是其它的可能堵塞通风口的物体的间距至少 5cm。  WARNING: Before the power cable is installed or removed, the power switch must be turned off.  Warnung: Das System muss stets abgeschaltet werden, bevor die Zuleitung angebracht oder entfernt wird. 警告:在安装、移动线缆之前,请切断电源。  WARNING: Before the power cable is connected, it must be confirmed that the power cable and label comply with the requirements of the
 3 actual installation. Warnung: Überprüfen Sie vor dem Anbringen der Zuleitung immer, ob das von Ihnen verwendete Kabel den Anforderungen entspricht. 警告:在进行线缆连接前,请确认线缆和线缆的标识与实际安装要求是一致的。  WARNING: The unit must be permanently connected to the protective ground before operation. The cross-sectional area of the protective earthing / grounding conductor shall be at least 0.75 mm2. Warnung: Diese Anlage muss vor der Inbetriebnahme ständig an die Schutzleiter angeschlossen werden. Die Querschnittsfläche des Schutzerdungsleiters soll mindestens 0.75 mm2 betragen. 警告:进行设备/系统操作前,请确保永久接地,并且用于进行保护接地连接的接地线截面不小于0.75 mm2。  WARNING: To ensure the equipment mounted on the wall firmly, please use nail at least 4.2 mm diameter and the nail cap at least 8 mm diameter. Warnung: Um die Sicherheit der Ausrüstung auf der Wand, der Nagel in der Wand muss  einen Durchmesser 4.2 mm mindestens haben und der Durchmesser von der Nagelkappe muss groesser als 8 mm sein. 警告:为确保设备紧固的安装在墙上,请用直径最小是4.2mm钉子,并且钉子帽的直径要大于8mm。  Electricity Safety Elektrische Sicherheit 用电安全  • Conducting articles, such as watch, hand chain, bracelet and ring are prohibited during the operation. • Es ist nicht erlaubt während dieser Arbeiten leitende Gegenstände wie Uhren, Armbänder, Armreifen und Ringe am Körper zu tragen. • 在操作中不能穿戴导电性的物品,如:手表,手琏,手镯和项链等。 • When water is found in the rack, or the rack is damp, please immediately switch off the power supply.
 4 • Sollte sich Wasser im Baugruppenträger befinden oder der Baugruppenträger feucht sein, ist die Energiezufuhr sofort zu unterbrechen und das System abzuschalten. • 当有液体进入机架或机架有损坏时,请立即切断电源。 • When operation is performed in a damp environment, make sure that water is kept off the equipment.  • Muss in einem feuchten Umgebung gearbeitet werden, ist sicherzustellen, dass kein Wasser in die Ausrüstung dringen kann. • 在潮湿环境下进行安装时,请避免液体进入设备。
 5 Regulatory Compliance Information  Regulatory compliance standards  Table 2 Regulatory compliance standards Discipline Standards EMC FCC Part 15 (CFR 47) Subpart B section 15.107&15.109 Class B ICES-003 Class B EN 61000-3-2 EN 61000-3-3 EN55024 EN55022 EN 301 489-1 EN 301 489-17 Safety UL 60950-1 CAN/CSA C22.2 No 60950-1 IEC 60950-1 EN 60950-1 AS/NZS 60950-1 RF FCC Part 15 subpart C section 15.207 & 15.209 & 15.247& 15.205;  subpart D section 15.407 FCC Bulletin OET-65C RSS-210 EN 300 328 EN 301 893
 6 Support Antennas & Accessories information  This product can be used with the following antennas and accessories: Table 3 Authorized Antennas & Accessories  Item Description  Exclusions  Supplied Antenna  None JG291A  HP 2.4GHz 12dBi MIMO 3-element Outdoor/Indoor Panel Antenna  None JG292A  HP 5GHz 11dBi MIMO 3-element Outdoor/Indoor Panel Antenna  None This product does not contain any user serviceable components. Any unauthorized product changes or modifications will invalidate the warranty and all applicable regulatory certifications and approvals. This product must be installed by a professional technician/ installer. EU Compliance information  CE Marking  Table 4 Equipment may be operated in the following country: AT BE CY CZ DK EE FI  FR DE GR HU IE  IT  LV LT  LU MT NL  PL  PT  SK  SI  ES  SE GB IS  LI  NO CH BG RO TR
 7 1. Select the country in which the product is installed to ensure product operation is in compliance with local regulations. For more information about how to select the country, see command about country-code in "WLAN Command Reference". 2. Intended use: IEEE 802.11 a/b/g/n radio LAN device. 3. This product must maintain a minimum body to antenna distance of 20cm.Under these conditions this product will meet the Basic Restriction limits of 1999/519/EC(Council Recommendation of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields(0Hz-300GHz)). Table 5 R&TTE declaration statements:  Česky [Czech] HP Coporation tímto prohlašuje, že tento RLAN je ve shodě se základními požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES. Dansk [Danish] Undertegnede HP Corporation erklærer herved, at følgende udstyr RLAN overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF. Deutsch [German] Hiermit erklärt HP Corporation, dass sich das Gerät RLAN in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 1999/5/EG befindet. Eesti [Estonian] Käesolevaga kinnitab HP Corporation seadme RLAN vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele. English Hereby, HP Corporation, declares that this RLAN is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Español [Spanish] Por medio de la presente HP Corporation declara que el RLAN cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. Ελληνική [Greek] ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ HP Corporation ∆ΗΛΩΝΕΙ ΟΤΙ RLAN ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩ∆ΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ∆ΙΑΤΑΞΕΙΣ ΤΗΣ Ο∆ΗΓΙΑΣ 1999/5/ΕΚ. Français [French] Par la présente HP Corporation déclare que l'appareil RLAN est conforme aux exigences essentielles et aux autres dispositions
 8 pertinentes de la directive 1999/5/CE. Italiano [Italian] Con la presente HP Corporation dichiara che questo RLAN è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. Latviski [Latvian] Ar šo HP Corporation deklarē, ka RLAN atbilst Direktīvas 1999/5/EK būtiskajām prasībām un citiem ar to saistītajiem noteikumiem. Lietuvių [Lithuanian] Šiuo HP Corporation deklaruoja, kad šis RLAN atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas. Nederlands [Dutch] Hierbij verklaart HP Corporation dat het toestel RLAN in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. Malti [Maltese] Hawnhekk, HP Corporation, jiddikjara li dan RLAN jikkonforma mal-ħtiġijiet essenzjali u ma provvedimenti oħrajn relevanti li hemm fid-Dirrettiva 1999/5/EC. Magyar [Hungarian] Alulírott, HP Corporation nyilatkozom, hogy a RLAN megfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak. Polski [Polish] Niniejszym HP Corporation oświadcza, że RLAN jest zgodny z zasadniczymi wymogami oraz pozostałymi stosownymi postanowieniami Dyrektywy 1999/5/EC. Português [Portuguese]HP Corporation declara que este RLAN está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE. Slovensko [Slovenian] HP Corporation izjavlja, da je ta RLAN v skladu z bistvenimi zahtevami in ostalimi relevantnimi določili direktive 1999/5/ES. Slovensky [Slovak] HP Corporation týmto vyhlasuje, že RLAN spĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES. Suomi [Finnish] HP Corporation vakuuttaa täten että RLAN tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen. Svenska [Swedish] Härmed intygar HP Corporation att denna RLAN står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG.
 9 Íslenska [Icelandic] Hér með lýsir HP Corporation yfir því að RLAN er í samræmi við grunnkröfur og aðrar kröfur, sem gerðar eru í tilskipun 1999/5/EC. Norsk [Norwegian]HP Corporation erklærer herved at utstyret RLAN er i samsvar med de grunnleggende krav og øvrige relevante krav i direktiv 1999/5/EF.  A copy of the signed Declaration of Conformity can be downloaded from: • http://www.hp.eu/certificates Table 6 Overview of Regulatory Requirements for Wireless LANs Frequency Band (MHz)  Max Power Level  (EIRP) (mW) Indoor ONLY  Indoor and Outdoor 2400 – 2483.5  100 mW    X 5150 – 5350  200 mW  X   5470 – 5725  1000 mW    X   NOTE:  Dynamic Frequency Selection and Transmit Power Control is required in the 5250- to 5350-MHz and 5470- to 5725-MHz frequency range.   EU Country Restriction in 2.4GHz band The products may be used indoors or outdoors in all countries of the European Community using the 2.4GHz band: Channel 1-13, except where noted below.  In France, the output power is restricted to 10 mW EIRP when the product is used outdoors in the band 2454 - 2483.5 MHz. There are no restrictions when used in other parts of the 2.4 GHz band.
 10 EU Country Restriction in 5GHz band 1. In Italy the end-user must apply for a license from the national spectrum authority to operate this device outdoors.  2. To remain in conformance with European spectrum usage laws for Wireless LAN operation, the above 2.4GHz and 5GHz channel limitations apply. The user should check the current channel of operation. If operation is occurring outside of the allowable frequencies as listed above, the user must cease operating the product at that location and consult the local technical support staff responsible for the wireless network. 3. This device must be used with the radar detection feature required for European Community operation in the 5GHz bands. This device will avoid operating on a channel occupied by any radar system in the area. The presence of nearby radar operation may result in temporary interruption in communications of this device. The Access Point’s radar detection feature will automatically restart operation on a channel free of radar. You may consult with the local technical support staff responsible for the wireless network to ensure the Access Point device(s) are properly configured for European Community operation. Table 7 Europe-Restrictions for Use of 5GHz Frequencies in European Community Countries Allowed Frequency Bands  Allowed Channel Numbers  Countries 5.15-5.35&  5.470-5.725GHz 36,38,40,44,46,48,52,54,56,60,62,64,100,102,104,108,110,112,116,118,120,124,126,128,132,134,136,140 Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland, U.K.
 11 WEEE Directive–2002/96/EC  The products this manual refers to are covered by the Waste Electrical & Electronic Equipment (WEEE) Directive and must be disposed of in a responsible manner. USA regulatory compliance FCC Part 15 US Federal Communications Commission (FCC) EMC Compliance The product complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference.  2. This device must accept any interference received, including interference that may cause undesired operation. This device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio/television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
 12 • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Note: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.    RF Requirements  1. RF exposure Hazard Warning This device generates and radiates radio-frequency energy. In order to comply with FCC radio-frequency exposure guidelines for an uncontrolled environment, this equipment must be installed and operated while maintaining a minimum body to antenna distance of 20 cm (approximately 8 in.) 2. RF Frequency Requirements This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This device and its antenna must not be co-located or operating in conjunction with any other unauthorized antenna or transmitter.   For outdoor use: the equipment is with frequency band in 2400 - 2483.5 MHz, 5250-5350 MHz, and 5725-5850 MHz.
 13 Antennas Only use the supplied antenna. Unauthorized antennas, modifications or change to the antennas could violate FCC regulations and void the user’s authority to operate the equipment.   Canada regulatory compliance ICES-003 This Class B digital apparatus complies with Canadian ICES-003.  Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.  RF Compliance This device complies with Industry Canada licence-exempt RSS standard(s). Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of this device. L ‘ utilisation de ce dispositif est autorisée seulement aux conditions suivantes: (1) il ne doit pas produire de brouillage et (2) l’ utilisateur du dispositif doit étre prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif. The term "IC" before the equipment certification number only signifies that the Industry Canada technical specifications were met. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (EIRP) is not more than that required for successful communication. To prevent radio interference to the
 14 licensed service, this device is intended to be operated indoors and away from windows to provide maximum shielding. Equipment (or its transmit antenna) that is installed outdoors is subject to licensing.  Pour empecher que cet appareil cause du brouillage au service faisant l'objet d'une licence, il doit etre utilize a l'interieur et devrait etre place loin des fenetres afin de Fournier un ecram de blindage maximal. Si le matriel (ou son antenne d'emission) est installe a l'exterieur, il doit faire l'objet d'une licence. This device must not be co-located or operated in conjunction with any other unauthorized antenna or transmitter.  For outdoor use: the equipment is with frequency band in 2400 - 2483.5 MHz, 5250-5350 MHz, and 5725-5850 MHz.  Brazil RF Compliance  Este produto está homologado pela ANATEL, de acordo com os procedimentos regulamentados pela Resolução 242/2000 e atende aos requisitos técnicos aplicados.  Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário. Para maiores informações, consulte o site da ANATEL – www.anatel.gov.br Korea RF Compliance This device may cause radio interference during its operation. Therefore service in relation to human life security is not available.
 15  Taiwan regulatory statement 1. 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。 2. 射頻電信終端設備之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。所謂合法通信,係指依電信法規定作業之無線電信。低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。 3. 輸入、製造射頻電信終端設備之公司、商號或其使用者違反本辦法規定,擅自使用或變更無線電頻率、電功率者,除依電信法規定處罰外,電信總局並得撤銷其審驗合格證明。 4. 本機限在不干擾合法電台與不受被干擾保障條件下於室內使用。 5. 在5.25-5.35 秭赫頻帶內操作之無線資訊傳輸設備,限於室內使用。 6. 無線資訊傳輸設備的製造廠商應確保頻率穩定性,如依製造廠商使用手冊上所述正常操作,發射的信號應維持於操作頻帶中。 7. 為減少電磁波干擾,請妥適使用。