Hi G Tek IGST51433 ISO 18000-7 SENSOR TRANSPONDER User Manual

Hi-G-Tek Ltd ISO 18000-7 SENSOR TRANSPONDER Users Manual

Users Manual

ProprietaryNoticeThisdocumentcontainsHi‐G‐TekInc.proprietaryconfidentialinformationandmaynotbeusedordisclosedtootherpartiesinwholeorinpartwithoutpriorwrittenauthorizationfromHi‐G‐TekInc.UM4903_Rev1.1  18.7SecureSeriesTagsSensorTransponderCLIN:0004FA,0006FA Installation&OperationManualUnisysDelivering Global Visibility.
  Installation&Operation:SensorTransponderUM4903_Rev1.1 Page3of12DisclaimerandLimitationofLiabilityHi‐G‐TekInc.affiliates,officers,directors,employeesandagentsprovidetheinformationcontainedinthisManualonan“as‐is”basisanddonotmakeanyexpressorimpliedwarrantiesorrepresentationswithrespecttosuchinformationincluding,withoutlimitation,warrantiesastonon‐infringement,reliability,fitnessforaparticularpurposeorapplication,usefulness,completenessoraccuracy.Hi‐G‐TekInc.shallnotinanycircumstancesbeliabletoanypersonforanyspecial,incidental,indirectorconsequentialdamages,includingwithoutlimitation,damagesresultingfromuseoforrelianceoninformationpresentedherein,orlossofprofitsorrevenuesorcostsofreplacementgoods,evenifinformedinadvanceofthepossibilityofsuchdamages.CopyrightNoticeAllrightsreserved.Nopartofthisdocumentmaybereproducedortransmittedinanyformbyanymeans,photographic,electronic,mechanicalorotherwise,orusedinanyinformationstorageandretrievalsystem,withoutthepriorwrittenpermissionofHi‐G‐TekInc.Thisdocumentissubjecttochangewithoutpriornotice.ATTENTION•ThisHi‐G‐Tekproductisdesignedforcommercial/industrialuseonly,andshouldonlybehandledbypersonnelauthorizedbyHi‐G‐Tekrepresentatives.•InstallationmustbeperformedaccordingtothisGuide.•Usingonlycertifiedantennas:ItistheresponsibilityoftheinstallertoensurethatwhenusingtheoutdoorantennakitsintheUnitedStates(orwhereFCCrulesapply),onlythoseantennascertifiedwiththeproductareused.•TheuseofanyantennaotherthanthosecertifiedwiththeproductisexpresslyforbiddeninaccordancewithFCCrulesCFR47part15.204andpart15.203.TheFCCWantsYoutoKnowThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttoPart15oftheFCCrules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:a)Reorientorrelocatethereceivingantenna.b)Increasetheseparationbetweentheequipmentandreceiver.c)Connecttheequipmenttoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.d)Consultthedealeroranexperiencedradio/TVtechnician.
  Installation&Operation:SensorTransponderUM4903_Rev1.1 Page4of12FCCWarningModificationsnotexpresslyapprovedbythemanufacturercouldvoidtheuserauthoritytooperatetheequipmentunderFCCRules.Instructionsconcerninghumanexposuretoradiofrequencyelectromagneticfields:Adistanceofatleast20cm.betweentheequipmentandallpersonsshouldbemaintainedduringtheoperationoftheequipment.FCCID:OB6‐IGST51433SensorTransponder–IG‐ST‐51‐433,CLIN#0004FASparePartsHi‐G‐Tekrecommendsthatonlyoriginalproducts,spareandreplacementpartsauthorizedbyHi‐G‐TekInc.beusedforinstallation,serviceandrepair.Hi‐G‐TekInc.doesnotacceptanyresponsibilityandwillnotbeliableforanyconsequencesduetoimpropermaterialsused.Hi‐G‐Tek,Inc.1445ResearchBlvd.Suite150Rockville,MD20850USAinfo@higtek.comOffice:+1‐301‐279‐0022Fax:+1‐301‐279‐0055
  Installation&Operation:SensorTransponderUM4903_Rev1.1 Page5of12TableofContent1 Introduction......................................................................................................................................................62 Functionaldescription.................................................................................................................................63 Installation.........................................................................................................................................................73.1 Preparingfordeployment.................................................................................................................73.2 MountingtheTransponder..............................................................................................................84 Operation...........................................................................................................................................................94.1 LampTest.................................................................................................................................................95 TechnicalSpecifications............................................................................................................................10ListofFiguresFigure1:SensorTransponder............................................................................................................................6Figure2:Installingthebattery...........................................................................................................................7Figure3:Magneticmountingoftransponder..............................................................................................8Figure4:Usingamountingattachment.........................................................................................................8
  Installation&Operation:SensorTransponderUM4903_Rev1.1 Page6of121 IInnttrroodduuccttiioonnTheSecureSeries18000‐7SensorTransponderCLIN#0004FAisanactiveRFIDtagformonitoringgoodseitherinyardlocationsorintransit.Figure1:SensorTransponderThetransponderisdesignedtobemagneticallyattachedtometallicsurfacesorbemountedonapoleorsimilarposts.TheSensorTransponderisequippedwithenvironmentcontrolsensorsforclimatecontrolofsensitivegoodsstoredincontainer.2 FFuunnccttiioonnaallddeessccrriippttiioonnTheSensorTransponderoperatesinthe433.92MHzUHFband.TheTransponderhasenvironmentalsensorsthatinclude:• Temperaturesensor:MonitorsTemperatureinsidecontainer.• Humiditysensor:Monitorshumidityinsidecontainer.Allthesensorsincludeindicationsforactivation/deactivationandalarmstatus.Theindicatorscolorsare:• Greencolordesignatesallnormalcondition.• Redcolor–indicatesanalarmevent.Eachsensorhasthresholdvalues–thatmaybeconfiguredbythecontrolsoftware.ALEDtestbuttonfacilitatesvalidationofsensorstatus.TheTransponderisbatterypowered,andrespondstostatusrequisitionsfromanearbyinterrogator–locatedup100mfromthetransponder.ControlofTransponder’sfeaturesandparametersisfacilitatedbycontrolsoftware.AccesscontrolmaybeachievedeitherviaaninterrogatorunitordirectlybyUSBconnectiontoacontrolPC.
  Installation&Operation:SensorTransponderUM4903_Rev1.1 Page7of123 IInnssttaallllaattiioonn3.1 PreparingfordeploymentBeforedeployment,opentheSensorTransponderbatterycoverbyhalfrotatingitcounterclockwise.Figure2:InstallingthebatteryRemovethebatteryandplaceitbackwiththepolesreversed,(+)sideshouldpointout.Whenyouhearashortbeep,thetransponderisactivatedandreadyforoperation.Ifnobeepisheard,eitherthebatteryisnotproperlyorientedoritneedstobereplaced.WhenpressingtheLEDtestbuttonforashortwhile,thetagwilldisplaythecurrentTemp/Humidityalarmstatusasperits(configurable)alarmlogic,oncethetestbuttonispressed,theLEDindicatorsshouldturnongreenandthenred,incaseofalarm,ablinkinggreenwillappearinthecorrespondingalarmindicator.Thetagalsoindicatesdepletedbatterywarning(batteryLEDturnsred) Note:   Replacement of depleted Battery:  When required, use only size 3.6V Lithium Li-SOCl2 Non rechargeable batteries Type LS 17500, manufactured by Saft Batteries.
  Installation&Operation:SensorTransponderUM4903_Rev1.1 Page8of123.2 MountingtheTransponder• Option1:MagneticMountingslocatedontransponderbase–noattachmentsneeded.Forlocationswithmetalsurfaces,thetransponderbyitselfcanbemagneticallyattachedtothesurface.Figure3:Magneticmountingoftransponder• Option2:MountingtransponderwithMountingBracketThetranspondercanutilizeamountingbracket,whichallowsforeasyremovalandreplacementoftransponder.Attachthemountingbrackettotherequiredsurfaceusingzipties/orscrewsifpermitted–seeFigure4.Slidethetransponderintothebracketandpresstopofbracketdownuntilthetransponderissecurelysituated.Figure4:Usingamountingattachment 3 magnet
  Installation&Operation:SensorTransponderUM4903_Rev1.1 Page9of124 OOppeerraattiioonnTheTransponderoperatesonlyuponarequestfromtheinterrogatororwhenoperatedbyacontrolPCconnectedtoitviaUSB.4.1 LampTest• presstheLEDtestbutton–seeFigure2.• AlltheLEDSblinkredoncethenblinkoncegreenandthenblink3timesandshowsensorstatusasfollows: Green:sensorisactive Red:sensorhasdetectedanalarm(thedetectedsignalwasabovethedefinedthresholdlevel) Nolight:sensorisdisabled
  Installation&Operation:SensorTransponderUM4903_Rev1.1 Page10of125 TTeecchhnniiccaallSSppeecciiffiiccaattiioonnssCommunications• Operatingfrequency• OmniDirectionalread/writerange433.92MHZUpto300feet(100meters)openspaceMemoryMemorysize 128KbytesofavailabledatabasetablememorySensordatalogging 32KbytesofmemoryforsensordataloggingDataretention DataisstoredforaminimumoffiveyearsPowerRequirementsBattery• Replaceable batteries, meet the requirements of theDoDtransponderbatteryguidelines.• Canbereplacedwithouttheneedforatool• SupportsreversebatteryinsertionforbatterystorageBatterytype 3.8VLithiumLi‐SOCl2batteriesBatterylife3yearminimumSerialCommunicationUSB:forlocalaccessandconfigurationEnvironmentalOperatingtemperature ‐30ºCto+70ºCStoragetemperature ‐40ºCto+70ºCHumidity 90%non‐condensingVibrationandshock ComplieswithMIL‐STD‐810DformobileHardenedweatherproof ComplieswiththeIEC60529IP64ratingPhysicalDimensionsSize 185x60x50mmWeight 250grMountingbracketWeight185x68x17mm160grAntenna InternalAttachmentmethods:• BracketwithmagneticmountgradeN28orhigher• Mountingbracketwith4holesonbracketfortiewrapattachmentSensors• Temperature• Humidity
  Installation&Operation:SensorTransponderUM4903_Rev1.1 Page11of12Indicators• Audiblebeepindicatorforpoweron.• Eachsensorhasitsindicationforactivation/deactivationandalarmstatus• BatteryhasanindicationforbatteryOKandundervoltageindicationStandards• FCCpart15subpartBclassB,subpartCsection15.231• CompliantwithISO18000‐7:2008standardsandtheDoDinteroperabilityguidelines• Hazardousenvironment:CertifiedasNon‐Incendive(NI)foroperationinenvironmentwhereflammableandexplosivegasesandvaporsmaybepresent• CompliantwithHEROenvironmenttestingat1‐inchseparation• ComplieswithapplicableDoD,nationalandinternationalspectrummanagementpoliciesandregulationstoincludespectrumcertificationsinaccordancewithDoDDirective4650.1“ManagementanduseoftheRadioFrequencySpectrum”andDoDDirective5000.1
  Installation&Operation:SensorTransponderUM4903_Rev1.1 Page12of12  

Navigation menu