User Manual
Hi-G-Tek SPDS WIRELESS ADAPTOR User Manual UM4801 Date: 26-Nov-13 Rev: 1.5 1. Introduction The following instructions describe and illustrate the principle steps involved in installation of RFID tags operating as SPDS bottom valve wireless adaptor and SPDS vapor pressure valve wireless adaptor. The SPDS tag is portable, reusable electronic device designed to monitors the access point through sensors and generate status information and alarms corresponding to various programmed conditions. The wireless adaptor tag uses RFID (Radio Frequency Identification) wireless technology- and includes a transmitter/ receiver unit, read/write capability, real-time clock, memory sensing circuitry for sealing verification. 2. Product Models This manual described the use of the products listed in the following table. Due to differences in regulations regarding the use of RF spectrum, a product should be used according to the following table: Model Number Used in IG-SPV-40-433 Europe or where the EU directives apply. IG-SBV-40-433 IG-SBV-40-916 Where the FCC regulation apply. IG-SBV-40-916 Forbidden for use in Europe. 3. Safety Precautions NOTE: The SPDS wireless adaptor electronic tag is powered by internal, irreplaceable 3.6V cell; do not drill into or attempt to open any part of the tag housing. USE HIGTEK APPROVED SERVICE Only approved service personnel must work on this product. HAZARDOUS ENVIRONMENT The Use of wireless adaptor tag is subject to the product safety classification given in section 6 : “ATEX product marking”, in this user guide. For all other safety aspects, Please refer to the enclosed EC- type examination certificate (page 8) ACCESSORIES Use only approved accessories. Do not connect incompatible devices. When connecting to any other device, please consult with Hi-G-Tek Engineering Department prior to installation. SPDS wireless adaptor- User Manual Page 2 The device must not be used within non-conductive flowing media. To the externals (Sensor-1, Sensor-2, Sensor-3 and Common) only passive components, according to the user manual of the manufacturer, must be connected. Switches and resistors must meet the simple apparatus requirements according to EN 60079-11. Resistors must meet the current-limiting resistors requirements according to EN60079-11. The assembly of the connected components must comply with the clearances and creepage distances requirements according to EN60079-11. The FCC Wants You to Know “This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) This device must accept any interference received, including interference that may cause undesired operation." This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: a) Reorient or relocate the receiving antenna. b) Increase the separation between the equipment and receiver. c) Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. d) Consult the dealer or an experienced radio/TV technician. FCC Warning Modifications not expressly approved by the manufacturer could void the user authority to operate the equipment under FCC Rules. Instructions concerning human exposure to radio frequency electromagnetic fields: A distance of at least 20cm. between the equipment and all persons should be maintained during the operation of the equipment. SPDS wireless adaptor- User Manual Page 3 4. SPDS bottom valve wireless adaptor Product Part No. IGSBV40xxx 4.1. General Adaptor shape is similar to the Data-Seal enclosure with the required modifications for cable connection. RF channels specifications are identical to the Data-Seal. 4.2. I/O’s The adaptor has 3 inputs and internal reed switch. The internal reed switch is used to sense removing of the enclosure from installation fixture. A magnet should be installed in the fixture. See figure 1 and 2 for reed switch location. NCND D4X5mm magnet is recommended. Locate a magnet in one of reed switch ends. Each one of the three inputs can be configured to work in digital mode or analog mode. Digital mode gives the basic ON/OFF functionality without tamper proof of the cable. In analog mode, the sensor ON/OFF states are sensed and cable short or disconnect are sensed as well. 73 73 6.5 6.5 21.7 24.7 Figure 1: Internal reed sw. location without rubber Jacket Figure 2: Internal reed sw. location with rubber Jacket 4.3. Setting Digital /Analog mode To work in digital mode simply connect the sensing switch to the cable. To work in analog mode connect the sensor according to Figure 3 below. SENSOR-3 SENSOR-2 1.6Meg 5% 3 2 5.1Meg 5% 4 1 Sensing reed switch Figure 3: Connecting the sensor: SPDS wireless adaptor- User Manual SENSOR-1 COMMON FRONT VIEW Page 4 4.4. Input specifications: Input type: Dry contact. Polarity: Internally pulled HIGH, Activated when pulled LOW. Protections: ESD. RED BLACK RED GREEN GREEN BLACK PIN # WHITE BLACK SHIELD WHITE 2 3 1 4 FRONT VIEW BLACK Figure 4: Extension cord (p/n IGSBVEC01): Pinout & wiring diagram: SPDS wireless adaptor- User Manual Page 5 5. SPDS vapor pressure valve wireless adaptor Product Part No. IGSPV40xxx 5.1. General Adaptor shape is similar to the DataSeal enclosure with the required modifications for cable connection. RF channels specifications are identical to the DataSeal. The adaptor controls the relay of the pneumatic system and reads the status of the air pressure. 5.2. I/O’s The adaptor has one input, one output and internal reed switch. The internal reed switch is used to sense removing of the enclosure from installation fixture. A magnet should be installed in the fixture. See figure 1 and 2 for reed switch location. NCND D4X5mm magnet is recommended. Locate a magnet in one of reed switch ends. The input can be configured to work in digital mode or analog mode. Digital mode gives the basic ON/OFF functionality without tamper proof of the cable. In analog mode, the sensor ON/OFF states are sensed and cable short or disconnect are sensed as well. To work in digital mode simply connect the sensing switch to the cable. To work in analog mode connect the sensor according to Figure 3. 5.3. Output specifications: The output is open drain type with specifications as follows: Output type: Open-drain. Maximum load: 24VDC relay with 230Ω minimum resistance. Maximum open circuit voltage: 32V. Functionality: ON- Pulse with configurable width. Maximum ON pulse width: 10Sec. Protection diode should be connected externally on relay terminals. Extension cord (IGSPVEC01) pinout diagram: RED PIN # GREEN WHITE BLACK SPDS wireless adaptor- User Manual 2 3 1 4 FRONT VIEW Page 6 6. Technical specifications. Power requirements Power Source 3.6V internal Lithium battery Life Expectancy 4 years at 50 readings per day Communication channels: Low frequency 125 kHz Low-frequency range Up to 40cm High frequency High-frequency range Model:IGSxV40433 433.92MHz Model:IGSxV40916 916.50MHz Up to 100m (in open space) Antenna Characteristics Beam Divergence Omni-directional on non-metal wall Hemispherical on metal wall Polarization Vertical Physical Characteristics: Dimensions 63 x 49 x 37mm (without pin and lock) Weight 150gr Environmental Conditions Operating Temperature : -40°C to +70°C Storage Temperature : -40°C to +80°C Protection Classification : IP65 I/Os Input type Polarity SPDS wireless adaptor- User Manual Dry contact Internally pulled HIGH, Activated when pulled LOW. Protections: ESD. Page 7 7. ATEX Marking 0539 II 1 G Ex ia IIB T4 II – Equipment Group II: Surface (no-mining) equipment. 2 - Equipment Category 1: Very high degree of protection for use in Zone 0. G – Atmosphere Group: Gases, Vapors, Mists Ex- Explosion proof equipment: The Equipment that has been certified for use in a Potentially Explosive Atmosphere ia - A protection technique based upon the restriction of electrical energy within the apparatus and in the interconnecting wiring, exposed to a explosive atmosphere, to a level below that which can cause ignition by either sparking or heating effects. “ia” - Indicates that the electric circuit is not able to cause an ignition when there are two failures (“ib” is for a single failure situation). IIB - Gas group B: Ethylene - typical gas in petrochemical environment. T4- Temperature classification (max.135ºC) SPDS wireless adaptor- User Manual Page 8 SPDS wireless adaptor- User Manual Page 9 SPDS wireless adaptor- User Manual Page 10 SPDS wireless adaptor- User Manual Page 11
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 11 Language : en-US Tagged PDF : Yes Title : Hi-G-Tek Author : Yossi Hershko Creator : Microsoft® Word 2010 Create Date : 2013:11:26 15:55:26+02:00 Modify Date : 2013:11:26 15:55:26+02:00 Producer : Microsoft® Word 2010EXIF Metadata provided by EXIF.tools