Honda Ems4000 Owners Manual
EMS4500 31ZA1611
2014-11-13
: Honda Honda-Ems4000-Owners-Manual-108405 honda-ems4000-owners-manual-108405 honda pdf
Open the PDF directly: View PDF
.
Page Count: 49
| Download | |
| Open PDF In Browser | View PDF |
Owner’s Manual EMS4000, l EMS4500 H Q HONDA I I - I MOTOR I CO., LTD. 1983 ! J 11 _ _ _ I 31ZA1611 00X31-ZAl-6110 I I I I @ Printed on Recycled Paper i 1 I I AH D PRI rR I I 1 I I Thank you for purchasing a Honda generator. This manual covers operation and maintenance of EMS4000 and EMS4500 generators. All information in this publication is based on the latest product information available at the time of approval for printing. Honda Motor Co., Ltd. reserves the right to make changes at any time without notice and without incurring any obligation. No part of this put :ation may be reproduced without This manual should be considered a permanent remain with the generator if it is sold. Pay special attention NOTE: Indicates a possibility are not followed. Gives helpful permission. part of the generator to statements preceded by the following w Indicates a strong possibility life if instructions are not followed. CAUTION: instructions written and words: of severe personal injury or loss of of personal injury or equipment damage if information. If a problem should arise, or if you have any questions about the generator, consult an authorized Honda dealer. w Honda generators are designed to give safe and dependable service if operated according to instructions. Read and understand the Owner’s Manual before operating the generator. Failure to do so could result in personal injury or equipment damage. 1 CONTENTS CONTENTS ................................... 1. GENERATOR SAFETY ............................ 2. COMPONENT IDENTIFICATION 3. PRE-OPERATION CHECK ................................. 4. STARTING THE ENGINE .................................. 5. GENERATOR USE ....................................... 6. STOPPING THE ENGINE .... ;. ............................ ......................................... 7,MAlNTENANCE ............................... 8. TRANSPORTING/STORAGE .................................... 9. TROUBLESHOOTING ......................................... 10. SPECIFICATIONS ...................................... 11. WIRING DIAGRAM 12. INSTALLATION OF OPTIONAL PARTS ..................... 13. WARRANTY SERVICE .................................... 2 3 4 6 g 16 19 21 30 32 35 36 38 43 1. GENERATOR To ensure safe operation l l l l l l l SAFETY - Place the generator at least 1 m (3 ft) away from buildings or other equipment while operating. Operate the generator on a level surface. If the generator is tilted, fuel spillage may result. Exhaust gas contains poisonous carbon monoxide. Never run the generator in an enclosed area. Be sure to provide adequate ventilation. Know how to stop the generator quickly and understand operation of all the controls. Never permit anyone to operate the generator without proper instructions. Keep children and pets away from the generator when it is in operation. Keep away from rotating parts while the generator is running. The generator is a potential source of electrical shocks when misused; do not operate with wet hands. Do not operate the generator in rain or snow and do not let it get wet. 3 2. COMPONENT IDENTIFICATION VOLT METER VOLTAGE SELECTOR SWITCH AUTO-THROTTLE SWITCH ENGINE SWITCU \ w OIL ALERT SWITCH FIIFI VAIVF- DC Cl RCUIT PROTECTOR \I AC RECEPTACLE RECOIL STARTER GRIP DC TERMINALS ENGINE OIL DRAIN PLUG (EMS45001 4 3. PRE-OPERATION CAUTION: stopped. CHECK Be sure to check the generatot- on a level surface with the engine 1. Check the engine oil level. CAUTION: Engine oil is a major factor affecting engine performance and service life, Non-detergent and S-stroke engine oils are not recommended. Use Honda 4-stroke oil, or an equivalent high detergent, premium quality motor oil certified to meet or exceed U.S. automobile manufacturer’s requirements for Service Classification SE or SF. (Motor oils classified SE or SF will show this designation on the container.) SAE low-40 is recommended for general, all-temperature use. Remove the oil filler cap, and wipe the dipstick oil the dipstick level by inserting in the filler with a clean rag. Check the hole without If the oil level is below the end of the dipstick, filler neck. -20 -30 FILLER HOLE OIL FILLER CAP screwing it in. add oil to the top of the oil 0 -20 20 -10 40 0 60 10 20 60 30 lO(rF 4O'C NOTE: The Oil Alert System will automatically stop the engine before the oil level falls below the safe limit. However, to avoid the inconv.enience of an unexpected shutdown, it is still advisable to visually Inspect the oil level regularly. If the Oil Alert Switch is tripped, add oil to the top of the oil filler neck, reset the Oil Alert Switch, and restart the engine according to instructions (P.9). OIL ALERT SWITCH 7 2. Check the fuel level. Use any brand of regular grade automotive gasoline (unleaded gasoline is preferred) with an antiknock index of 86 or higher as calculated using the Cost of Living Council formula (equal to 91 Research Octane Number or higher.) Never use an oil/gasoline mixture or water in the fuel tank. or dirty gasoline. Avoid getting dirt, dust CAUTION: Gasoline substitutes are not harmful to fuel system components. recommended; they may be Gasoline is extremely flammable and explosive under certain conditions. Refuel in a well ventilated area with the engine stopped. l Do not smoke or allow flames or sparks in the area where the generator is refueled or where gasoline is stored. e Do not overfill the tank and make sure the filler cap is securely closed after refueling. l Be careful not to spill fuel when refueling. Fuel vapor or spilled fuel may ignite. If any fuel is spilled, make sure the area is dry before starting the engine. l L VELGAUGE d/ I i I ~- r 1 r-----.1 I If a battery is used 3. Check that the battery electrolyte level’ is between the marks on the case. Be sure that the cable connections are secure. (See pages 38 and 39.) 8 4. STARTING THE ENGINE NOTE: Make sure that the AC circuit breaker is OFF and that nothing connected to the DC terminals. The generator may be hard to start if a load is connected. AC CIRCUIT BREAKER DC TERMINALS 9 [ MANUAL STARTING ] 1, Turn the fuel valve on. FUEL VALVE 2. Pull the choke rod out to CLOSE. CHOKE ROD 3. Make sure the Oil Alert switch is on. OIL ALERT 10 @‘ITCH 4. Make sure the auto-throttle warm up. AUTO-THROTTLE switch is off, or more time will be required fc SWITCH 5. Turn the engine switch on. ENGINE SWITCH 6. Pull the starter grip until compression NOTE: hand. is felt, then pull briskly. Do not allow the starter grip to snap back. Return it slowly STARTER by GRIP 11 7. Push the choke rod to OPEN as the engine warms up. CHOKE ROD 8. If auto-throttle will be used, turn the switch to “AUTO” has warmed up. AUTO-THROTTLE 12 SWITCH after the engine [ ELECTRIC STARTING ] 1. Turn the fuel valve on. FUEL VALVE 2. Make sure the oil alert switch is on. 3. Make sure the auto-throttle warm up. switch is off, or more time will be required for AUTO-THROTTLE SWITCH 13 4. Turn the engine switch to START and hold it there until the engine starts. NOTE: If a relay switch on 0 When the indication l box is attached for remote control operation, make sure the the relay box is turned off, or the engine will not start. speed of the starter motor drops after a period of time, it is an that the battery should be recharged. 5. After the engine starts, let the engine switch return to ON. 14 6. Turn the auto-throttle switch to AUTo I AUTO-THROTTLE after the engine has warmed up. SWITCH NOTE: The choke is operated automatically ed to the generator’s starting circuit. whenever a battery is connect- 15 5. GENERATOR USE N To prevent electrical shock from faulty appliances, the generator should be grounded. Connect a length of heavy wire between the ground terminal and the ground source. CAUTION: Limit operation requiring maximum power (EMS4000 : 4.0 kW, EMS4500 : 4.5 kW) to 30 minutes. For continuous operation, do not exceed the rated power (EMS4000 : 3.8 kW, EMS4500 : 4.0 kW). In either case, the total wattage of all appliances connected must be considered. l Do not exceed the current limit specified for any one receptacle. l Connections for standby power to household circuits must be made by a qualified electrician and must comply with all applicable laws and electrical codes. Improper installation may result in personal injury or damage to equipment or property. l Auto-throttle system With the switch in the AUTO position, engine speed is automatically reduced to an idle when all loads are turned off or disconnected. When appliances are turned on or reconnected, the engine resumes the rated speed. At OFF, the auto-throttle system does not operate. NOTE: l AUTO is recommended to minimize fuel consumption. l The auto-throttle system will not respond to electrical loads of less than 1 ampere. l The system is not effective for use with appliances that require only momentary power. To avoid extended warm-up periods, keep the switch OFF until the engine reaches operating temperature. 16 AC applications 1. Start the engine and make sure the pilot lamp comes on. If not, the filament may be burnt out. 2. Turn the voltage selector switch to either position as required. When the switch is turned to “12OV ONLY” position, you can use only 120V AC. At “12OV/24OV” position, you can use both 120V and 240V receptacles. 3. Switch on the AC Circuit Breaker. 4. Plug in the appl’iance. CAUTION: than Be sure that appliances do not exceed the rated load for more 30 minutes, and never exceed the maximum load. Substantial over- loading will switch off the circuit breaker. Marginal overloading may not switch off the circuit breaker, but it will shorten the service life of the generator. Be sure that all appliances are in good working order before connecting them to the generator. If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn off the circuit breaker and the generator engine switch immediately. Then disconnect the appliance and examine it for signs of malfunction. NOTE: This generator is equipped Regulator) for stable voltage supply. with PI LOT LAMP / an AVR (Automatic Voltage AC CIRCUIT /BREAKER VOLTAGE SELECTOR SWITCH 17 DC application The DC terminals only. may be used for charging 12 volt automotive-type batteries m Batteries produce explosive gases. Keep sparks, flames, and cigarettes away. To prevent the possibility of creating a spark near the battery, connect charging cables first to the battery, then to the generator, and disconnect cables first at the generator. CAUTION: l Do not attempt to start an automobile engine while the generator is still connected to the battery. The generator may be damaged. l Connect the positive battery terminal to the positive generator terminal. Do not reverse the charging cables, or serious damage to the generator and/or battery may occur. NOTE: The DC terminals may be used while the AC power is in use. l An overloaded DC circuit will trip the DC circuit protector (push button comes out). If this happens, wait a few minutes before pushing the circuit protector to resume operation. l NEGATIVE’ TERMINAL (BLACK) 18 POSITIVE TERMINAL, (RED) 6. STOPPING NOTE: THE ENGINE To stop the engine in an emergency, turn the engine switch OFF. In normal use: 1. Turn the AC circuit DC terminals. breaker off and/or disconnect the charging leads at the AC CIRCUIT BREAKER 2. Turn the engine switch OFF. ENGINE SWITCH 19 3. Turn the fuel valve OFF. FUEL VALVE 20 7. MAINTENANCE The purpose of the maintenance schedule is to keep the generator in the best possible operating condition. Inspect or service as scheduled in the table’on the next page. m Shut off the engine before performing any maintenance. If the engine must be run, make sure the area is well ventilated. The ezhaust contains poisonous carbon monoxide gas. CAUTION: replacement generator. Use only genuine HONDA parts or their equivalent. The use of parts which are not of equivalent quality may damage the 21 Maintenance Schedule REGULAR SERVICE Perform at every indicated month or operating hour interval, whichever occurs Inspection Daily First month or 20 Hrs. Every 3 months 60’Lrs. Every 6 months or 100 Hrs. Every year 3000trlrs. 0 Engine oil 0 0 Change l . (1) Fuel filter cleaning 0 Spark plug maintenance l Valve clearance adjustment l (21 Combustion chamber and valve cleaning . (2) Fuel line inspection (Replace if necessary) Spark arrester 0 Clean every 100 operating hours. NOTE (1) : Service more frequently when used in dusty areas. (2) : These items should be serviced by an authorized Honda dealer, unless the ’ owner has the proper tools and is mechanically proficient. See the Honda Shop Manual. 22 Tool kit The tools supplied are necessary for performing simple adjustments and repairs. Always keep the kit with the generator. some periodic maintenance, . Changing oil Drain the oil while draining. the engine is still warm to assure rapid and complete 1. Remove the drain plug and filler cap, and drain the oil. Retighten the plug securely. 2. Refill with the recommended oil (see page 6) and check the level. -OIL FILLER CAP DRAIN PLUG / .23 Air cleaner service A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air cleaner regularly (page 22). Service more frequently when operating the generator in extremely dusty areas, w Never use gasoline or low flash point solvents for cleaning the air cleaner element. A fire or explosion could result. CAUTION: Never run the generator wear will result. without the air cleaner. Rapid engine 1. Unsnap the clips, remove the air cleaner cover and remove the element. AIR CLEANER COVER ‘ \ CLIP / ‘CLIP 24 AIR CLEANER ELEMENT \ 2. Wash the element in a non-flammable or high flash point solvent and dry it thoroughly. 3. Soak the element in clean engine oil and squeeze out the excess oil. 4. Reinstall the air cleaner element and the cover. ELEMENT 25 Sediment cup service The sediment cup prevents dirt or water which may be in the fuel tank from entering the carburetor. If the engine has not been run for a long time, the cup should be cleaned. 1. Turn the fuel valve OFF. Remove the sediment cup. 2. Clean the cup thoroughly. 3. Reassemble. Do not damage the rubber gasket. m After installing the sediment cup, check for fuel leaks and make sure the area is dry before starting the engine, FUEL VALVE 26 Spark plug service Recommended spark plug: BPR4HS-10 (NGK) W14FPR-ULlO (ND) To ensure proper engine operation, and free of deposits. the spark plug ,must be properly gapped 1. Remove the spark plug cover. 2. Clean any dirt from around the spark plug base. 3. Remove the spark plug cap. PLUG CAP 27 4. Use the wrench supplied in the tool kit to remove the spark plug. 5. Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. 6. Measure the plug gap with a feeler gauge. The gap should be 0.9-l .O mm (0.035-0.039 in). Correct as necessary by bending the side electrode. 7. Attach the plug washer. Thread the plug in by hand to prevent cross-threading. 8. Tighten a new spark plug l/2 turn with the wrench to compress the washer. If you are reusing a plug, it should only take l/B-1/4 turn after the plug seats. CAUTION: The spark plug must be securely tightened. An improperly can become very hot and possibly damage the engine. l Never use a spark plug with an improper heat range. l tightened plug PLUG GAP 0.9-I .O mm lO.O35-0.039 28 in) Spark arrester maintenance m If the generator has been running, Allow it to cool before proceeding. the muffler will be very hot. CAUTION: The spark arrester must be serviced every 100 hours to maintain its efficiency. 1. 2. 3. 4. Loosen the bolts and nuts and remove the muffler. Loosen two Bmm bolts to remove the exhaust pipe. Check the muffler exhaust port for carbon deposits; clean if necessary. Remove the spark arrester from the muffler. Clean the screen with a stainless steel wire brush and inspect the mesh for damage. Replace the spark arrester if there are any holes or breaks in the screen. 5. Install the spark arrester in the muffler. 6. Install the muffler and gasket and tighten the bolts and nuts securely. EXHAUST 8mm NUTS PIPE I SPARK ARRESTER ,“FFLE/ PROTECTOR ” 6mm BOLTS 8mm GOLTS 29 8. TRANSPORTING/STORAGE w When transporting the generator, turn the engine switch OFF and keep the generator level to prevent fuel spillage. Fuel vapor or spilled fuel may ignite. Before storing the unit for an extended period: 1. Be sure the storage area is free of excessive humidity and dust. 2. Drain the fuel With the fuel valve OFF, remove and empty the sediment cup. i: Turn the fuel valve ON and drain the gasoline in the fuel tank into a suitable container. C. Replace the sediment cup and tighten securely. FUEL VALVE SEDIMENT CUP d. Drain the carburetor by loosening into a suitable container. the drain screw. Drain the gasoline . \ DRAIN SCREW e. Slowly pull the starter grip until resistance is felt. At this point, the piston is coming up on its compression stroke and both the intake and exhaust valves are closed. Storing the engine in this position will help to protect it from internal corrosion. STARTER GRIP 31 9. TROUBLESHOOTING A. When the engine will not start: 1. Is there enough fuel? 2. Is the fuel valve on? 3. Is gasoline reaching the carburetor? To check, loosen the drain screw with the fuel valve on. m If any fuel is spilled, make sure the area is dry before testing the spark plug or starting the engine. Fuel vapor or spilled fuel may ignite. DRAIN SCRE 4. Is there enough oil in the crankcase? Is the oil alert switch on? 5. Is the AC circuit breaker off and nothing connected to the terminals? 6. Is the engine switch on? 7. Is there a spark at the spark plug (page 27)? 32 DC a. Remove the spark plug cover and cap. Clean any dirt from around the spark plug base, then remove the spark plug. b. Install the spark plug in the plug cap. c. Turn the engine switch on. d. Be sure the oil alert switch is on. e. Grounding the side electrode to the stay, pull the recoil starter to see if sparks jump across the gap. GROUNDING STAY STARTER I \ 1 I -’ OIL ALERT SV?T CH -C ENGINE SWITCH f. If there are no sparks, replace the plug and check again. If OK, try to start the engine according to the instructions. 8. If there is still no spark or if the engine still does not start, take the generator to an authorized Honda dealer. 33 B. When the engine starts but stops immediately: Is there enough oil in the crankcase? If not, the oil alert switch will turn off after starting. C. No electricity at the AC receptacles: 1. Are the AC circuit breakers on? 2. Check the electrical appliance or equipment for any defects. D. No electricity at the DC terminals: 1. Is the DC circuit protector on? 2. Check the condition of the battery cables and the battery itself. 34 10. SPECIFICATIONS Dimensions Length x Width x Height 65Ox425x575mm (25.6 x 16.7 x 22.6 in) 85.0kg( 187.4lb) Dry weight 1 L Engine Honda G E400 4Stroke, side valve, 1 cylinder 406 cc (24.8 cu in) [B6 x 70 mm (3.4 x 2.8 in)] 6.8: 1 3,600 rpm Forced air cooling CDI (Capacitor Discharge Ignition) 1.2 Q (5.1 us qt) 16.5 L (4.4 US gal) BPR4HS10 (NGK) W14FPRULlO (ND) Model Engine Type Displacement (Bore x Stroke) Compression Ratio Engine Speed Cooling System Ignition System Oil Capacity Fuel Tank Capacity Spark Plug Generator EMS4500 EMS4000 MODEL 12OW/24OV Rated voltage 60Hz Rated frequency AC output Rated ampere 32.OA/I 6.OA Rated output 3.8kW(3.8kVA) 4.0kW(4.0kVA) Maximum 4.0kW(4.0kVA) 4.5kW(4.5kVA) output Only for charging DC output 33.5A/l6.5A 12 V automotive batteries. Maximum charging output=8.3A 35 11. WIRING DIAGRAMr ________________ ------------ ----------- ...... ...... ...... ...... ... ~ I I . . . . . . . . J>G ... III I .I gl! I L---------- __--___ -------------, 36 7 LL. ____. --.-.__._ -~.. -BLOCll 1 L... B . G . R . W Lg: P L::::: Y..... Gr. . . . . . . . . . . . . . . . : . . . . . . . .BLACK .GREEN RED .WHITE .LIGHT GREEN .PINK .BLUE .YELLOW .GRAY 12. INSTALLATION OF Ol?TIONAL PARTS Battery mount kit 1. Remove and retain the two bolts attaching the upper frame to the lower frame on the generator side. Position the battery guards on the lower frame and install using the bolts retained. (See page 39) 2. Position the battery tray on the battery guards and install with the attaching hardware shown. 3. Pass the starter cable between the control box and generator and connect to the outer terminal of the starter magnetic relay. 4. Attach the ground cable to the frame at the upper left of the generator as shown. Tighten securely. 5. Install the battery in the battery tray and connect the battery cables to the battery. NOTE: Use a battery rated at 12V-32AH CAUTION: Do not reverse polarity. battery may occur. or more. Serious damage to the generator and/or Battery NOTE: Check. the electrolyte level to be sure that it is between the marks on the case. If the level is below the lower mark, remove the caps and add distilled water to bring the electrolyte level to the upper mark. The cells should be equally full. 38 STARTER GROUND’ CABLE ’ BATTERY’ TRAY 39 Remote control kit The generator may be adapted for remote control operation with an optional kit. 1. Position the relay box on the tabs of the pipe frame on the right (generator) side and attach it with the two 6 mm screws. 2. Disconnect the 8-pin coupler from the back of the control box and connect the relay box coupler in its place. 3. Connect the remote control cable to the remote control box and the relay box. RELAY BOX I! REMOTE CONTROL BOX \ \ REMOTE CONTROL CABLE 40 Remote control operation (STARTING) 1. Turn the fuel valve on. 2. Turn the oil alert switch on. 3. Turn the auto-throttle switch off. 4. Turn the ignition switch key off or remove it from the generator. 5. Turn the relay switch on. RELAY SWITCH 6. Flip the remote control engine switch knob up to ON. Pull - ON 1 START 41 7. Depress the starter button until the engine starts. Be sure that pilot lamp comes on when the engine starts. NOTE: Do not hold the starter button on for more than 15 seconds at a time. If the engine has not started by then, check through the starting procedure above to be sure that all switches, valves, etc are in the correct position. 42 Warranty Owner Service Satisfaction Your satisfaction and goodwill are important to your dealer and to us. All Honda warranty details are explained in the Distributor’s Limited Warranty. Normally, any problems concerning the product will be handled by your dealer’s service department. If you have a warranty problem that has not been handled to your satisfaction, we suggest you take the following action: l l Discuss your problem with a member of dealership management. Often complaints can be quickly resolved at that level. If the problem has already been reviewed with the Service Manager, contact the owner of the dealership or the General Manager. If your problem still has not been resolved to your satisfaction, contact the Customer Relations Department at the zone service office of American Honda Motor Co., Inc. in your area. Zone service office locations are shown on the following page. We will need the following information in order to assist you: -Your -Engine -Date name, address, and telephone number model and serial number of purchase -Dealer name and address -Nature of the problem After reviewing all the facts involved, you will can be taken. Please bear in mind that your solved at the dealership, using the dealer’s personnel, so it is very important that your dealer. be advised of what action problem will likely be refacilities, equipment, and initial contact be with the Your purchase of a Honda engine is greatly appreciated by both the dealer and American Honda Motor Co., Inc. We want to assist you in every way possible to assure your complete satisfaction with your purchase. 43 Current customer service contact information: United States, Puerto Rico, and U.S. Virgin Islands: Honda Power Equipment dealership personnel are trained professionals. They should be able to answer any question you may have. If you encounter a problem that your dealer does not solve to your satisfaction, please discuss it with the dealership's management. The Service Manager or General Manager can help. Almost all problems are solved in this way. If you are dissatisfied with the decision made by the dealership's management, contact the Honda Power Equipment Customer Relations Office. You can write: American Honda Motor Co., Inc. Power Equipment Division Customer Relations Office 4900 Marconi Drive Alpharetta, GA 30005-8847 Or telephone: (770) 497-6400 M-F, 8:30 am - 7:00 pm EST When you write or call, please provide the following information: • Model and serial numbers • Name of the dealer who sold the Honda power equipment to you • Name and address of the dealer who services your equipment • Date of purchase • Your name, address, and telephone number • A detailed description of the problem Zone Service Office Locations I -. i ‘\ . .__. it--P,--.-.l WESTERN ZONE SERVICE OFFICE (includes Alaska end Hawaii) American Honda Motor Co.. Inc. Customer Relations Depanment P.O. Box 420 Gardena. CA 90247-0642 (213) 604.2400 ! I t, **\ L/.<..Jy y EASTERN ZONE SERVICE OFFICE (includesPuetto Rim) American Honda Motor Co., Inc. Customer Relations Depxtmern 1500 Morrison Parkway Alpharetta. GA 30201 (404) 442.zoo0
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Copy, Extract, Print high-res Create Date : 2001:01:26 09:22:47Z Creator : Acrobat Capture Server 2.01 Modify Date : 2008:08:23 11:58:28-04:00 Page Count : 49 Page Mode : UseOutlines Has XFA : No Creation Date : 2001:01:26 09:22:47Z Producer : Acrobat 4.0 Import Plug-in for Windows Mod Date : 2008:08:23 11:58:28-04:00 Metadata Date : 2008:08:23 11:58:28-04:00 Page Layout : SinglePageEXIF Metadata provided by EXIF.tools