Honeywell Security Sensor CoE PP300850SE DUAL TEC Motion Sensor User Manual 800 15445 B DT8050M QIG 12 10 13
Honeywell Security Sensor CoE DUAL TEC Motion Sensor 800 15445 B DT8050M QIG 12 10 13
Contents
- 1. User Manual (1 of 2).PDF
- 2. User Manual (2 of 2).PDF
User Manual (2 of 2).PDF
DRAFT - QUICK INSTALL GUIDE - 12/10/13 DT8050M DT8050M DT8050M DT8050M DUAL TEC® Motion Sensor DUAL TEC® Motion Sensor DUAL TEC® Motion Sensor DUAL TEC® Motion Sensor - Quick Installation Guide Quick Installation Guide (FR) Quick Installation Guide (SP) Quick Installation Guide (PG) 6' 9" - 8' 9" (2.1 - 2.7 m) 7' 6" Optimal (2.3 m) Optimal Optimal Optimal #6 (3.5 mm) #6 x 1 1/4" (3.5 mm x 32 mm) B A Internal EOL Resistor DIP Switches Résistance interne EOL commutateur DIP Interruptores DIP internos EOL Resistor EOL interno Resistor DIP Switches ON Not Used Not Used Not Used Not Used DT8050M EOL KOhm 1 2 2.2 5.6 EOL KOhm ON ON 1 2 2.2 5.6 AM LED ON OFF ON LED MAX PULL TO DISABLE LOOK DOWN MW SENSITIVITY W1 LOOK DOWN Microwave Range Adjustment Réglage de la portée Hyperfréquence Ajuste del rango de detección Microondas Ajuste de Alcance Microondas MAX MIN MW SENSITIVITY * Factory default / Réglage usine / Defecto de fábrica / Padrão de fábrica 5 24-20 AWG (0.2-0.52mm2) LED 0 VDC - Vsupply 1.8 mA max Trouble 30 mA 25 VDC Tamper 30 mA 25 VDC LED TBL TBL T Power 18 mA 9 - 15 VDC Alarm 30 mA 25 VDC NC V - V+ EOL 9 8 7 6 5 4 3 2 1 ON EOL KOhm 1 2 2.2 5.6 WIRING EXAMPLES / WIRING EXAMPLES / WIRING EXAMPLES To connect alarm and tamper outputs (NO trouble) to one zone input: All alarm and tamper events are “alarms” when the system is armed or “fault” when disarmed. Control Panel Zone Zone COM Ground +12V (SP) To connect alarm and tamper outputs (NO trouble) to one zone input: All alarm and tamper events are “alarms” when the system is armed or “fault” when disarmed. T C NC V- V+ 9 8 7 6 5 4 3 2 1 LED TBL TBL T (PG) To connect alarm and tamper outputs (NO trouble) to one zone input: All alarm and tamper events are “alarms” when the system is armed or “fault” when disarmed. Sensor (FR) To connect alarm and tamper outputs (NO trouble) to one zone input: All alarm and tamper events are “alarms” when the system is armed or “fault” when disarmed. (On-Board, Internal EOLR) EOL ON EOL KOhm 1 2 2.2 5.6 To connect all three outputs (sensor alarm, tamper and trouble) to one zone input: All alarm, tamper and trouble events are “alarms” when the system is armed or “fault” when disarmed. Control Panel Zone Zone COM Ground +12V ES) To connect all three outputs (sensor alarm, tamper and trouble) to one zone input: All alarm, tamper and trouble events are “alarms” when the system is armed or “fault” when disarmed. PG) To connect all three outputs (sensor alarm, tamper and trouble) to one zone input: All alarm, tamper and trouble events are “alarms” when the system is armed or “fault” when disarmed. T C NC V- V+ 9 8 7 6 5 4 3 2 1 LED TBL TBL T (On-Board, Internal EOLR) EOL ON EOL KOhm 1 2 2.2 5.6 -2- Sensor FR) To connect all three outputs (sensor alarm, tamper and trouble) to one zone input: All alarm, tamper and trouble events are “alarms” when the system is armed or “fault” when disarmed. To connect the sensor alarm output to one zone input and the tamper and trouble outputs to a second zone input: The alarm relay is wired to one zone; the tamper and trouble are wired to another zone; the control panel differentiates alarm conditions from tamper and trouble conditions. Control Panel Trouble Zone To connect the sensor alarm output to one zone input and the tamper and trouble outputs to a second zone input: The alarm relay is wired to one zone; the tamper and trouble are wired to another zone; the control panel differentiates alarm conditions from tamper and trouble conditions. Zone Alarm COM Zone Ground +12V JUMPER V- V+ 9 8 7 6 5 4 3 2 1 To connect the sensor alarm output to one zone input and the tamper and trouble outputs to a second zone input: The alarm relay is wired to one zone; the tamper and trouble are wired to another zone; the control panel differentiates alarm conditions from tamper and trouble conditions. NC Sensor LED TBL TBL T (On-Board, Internal EOLR) EOL W1 ON To connect the sensor alarm output to one zone input and the tamper and trouble outputs to a second zone input: The alarm relay is wired to one zone; the tamper and trouble are wired to another zone; the control panel differentiates alarm conditions from tamper and trouble conditions. Cut EOL KOhm 1 2 2.2 5.6 * Off-Board, External EOLR (Not supplied), best if installed inside the sensor housing. To connect the sensor alarm, tamper and trouble outputs to three separate zone inputs: The alarm, tamper and trouble are each wired to a separate zone; the control panel differentiates alarm, tamper and trouble conditions. Trouble Zone Zone COM Tamper Zone Alarm Zone COM Zone Ground +12V V- V+ 9 8 7 6 5 4 3 2 1 LED TBL TBL T To connect the sensor alarm, tamper and trouble outputs to three separate zone inputs: The alarm, tamper and trouble are each wired to a separate zone; the control panel differentiates alarm, tamper and trouble conditions. NC Sensor To connect the sensor alarm, tamper and trouble outputs to three separate zone inputs: The alarm, tamper and trouble are each wired to a separate zone; the control panel differentiates alarm, tamper and trouble conditions. Control Panel (On-Board, Internal EOLR) To connect the sensor alarm, tamper and trouble outputs to three separate zone inputs: The alarm, tamper and trouble are each wired to a separate zone; the control panel differentiates alarm, tamper and trouble conditions. EOL W1 ON Cut EOL KOhm 1 2 2.2 5.6 * Off-Board, External EOLR (Not supplied), best if installed inside the sensor housing. MAX 30 sec Walk Test Reset ON < 4 ft /1.2m MIN MW SENSITIVITY 4X (slowly) 10 45 LED 20 30 -3- LED Power Up Walk Test Normal Trouble Red Slow Blink ON Alarm ON Alarm Fast Blink Yellow OFF ON Microwave ON Microwave OFF Green OFF ON PIR ON PIR OFF 7 Top View Vue de dessus Vista Desde Arriba Vista Superior PLAN VIEW ALL ZONES Side View Vue de coté Vista Lateral Vista Lateral 40’ 12 m 33’ 10 m 27’ 8m 20’ 6m 13’ 4m 7’ 2m 2.3m 1.85 0.5 7’ 13’ 20’ 27’ 33’ 40’ 46’ 53’ 2 m 4 m 6 m 8 m 10 m 12 m 14 m 16 m A B Zones / Zones / Zonas / Zonas Look-down / Basses / Vista Zona 0 / Vigilância inferior 7’ 2m 13’ 4m 20’ 6m 12 Lower / Courtes / Cercana/ Mais baixas 10 Intermediate / Intermédiaires / Intermedia / Intermédias 36 Long / Longues / Largo Alcance / Longo alcance 27’ 8m 33’ 10 m 40’ 12 m 0 7’ 13’ 20’ 27’ 33’ 40’ 46’ 53’ 2 m 4 m 6 m 8 m 10 m 12 m 14 m 16 m APPROVAL/ LISTINGS: • • • • • FCC part 15, Class B verified IC ICES-003, Class B verified UL 639 ULC S306-03 SIA-PIR-01 Passive Infrared detector standard features for false alarm immunity. NOTES: Product must be tested at least once each year. For appropriate wiring methods, refer to the National Electrical Code NFPA 70 and the Canadian Electrical Code (where applicable). Power must be provided by a power-limited UL603 Listed burglar alarm power supply with minimum 4 hours of standby power capability, or from a power-limited output of a UL Listed burglar alarm control unit with minimum 4 hours of standby power capability. FEDERAL COMMUNICATIONS COMMISSION STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. CLASS B DIGITAL DEVICE STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • If using an indoor antenna, have a quality outdoor antenna installed. • Reorient the receiving antenna until interference is reduced or eliminated. • Move the radio or television receiver away from the receiver/control. • Move the antenna leads away from any wire runs to the receiver/control. • Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits. • Consult the dealer or an experienced radio/TV technician for help. INDUSTRY CANADA CLASS B STATEMENT This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. FCC / IC STATEMENT This device complies with Part 15 of the FCC Rules, and RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception indésirable. For the latest documentation and online support information, please go to: Pour de l’assistance en ligne, visitez : Para recibir soporte en línea, visite: Para qualquer informação adicional, contacte: http://www.security.honeywell.com/hsc/resources/MyWebTech/ To protect the environment, a detailed installation guide is available on the Honeywell website – Please consider before printing the document! For the latest U.S. warranty information, please go to: www.honeywell.com/security/hsc/resources/wa or Please contact your local authorized Honeywell representative for product warranty information. Pour obtenir de l'information sur la garantie de ce produit, veuillez communiquer avec le représentant autorisé de Honeywell de votre région. Por favor contacte con su distribuidor Honeywell Security para información sobre la garantía del producto. Contacte o representante autorizado Honeywell local para obter informações relativas a garantia. 2013 Honeywell International Inc. Honeywell and DUAL TEC are registered trademarks of Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved. Made in China. -4- 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 www.honeywell.com/security P/N 800-15445 12/13 Rev B
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : E727032 Create Date : 2013:12:10 05:58:37Z Modify Date : 2013:12:10 06:05:51-08:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Creator : E727032 Title : Microsoft Word - 800-15445-B_DT8050M-QIG_12-10-13 Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2013:12:10 06:05:51-08:00 Producer : GPL Ghostscript 8.15 Document ID : uuid:618859c4-4da3-4b11-8407-6d8fff2681dd Instance ID : uuid:37b116da-5c16-4063-84d7-5c5a5e063155 Page Count : 4EXIF Metadata provided by EXIF.tools