V-Plex® Series Motion Sensors DT8050A-SN V-Plex® DUAL TEC® Motion Sensor with Anti-Mask - Installation Instructions SELECT THE MOUNTING LOCATION 12” (30 cm) 6' 9" - 8' 9" (2.1 - 2.7 m) 7' 6" (2.3 m) Mounting location guidelines: • The optimal range is obtained at a mounting height of 7’ 6” (2.3m). • Allow a clear line-of-sight to all areas to protect. • Avoid mounting anything within 12” (30cm) in front of the sensor*. • Do not directly face windows. • Avoid close proximity to moving machinery, fluorescent lights, and heating/cooling sources. • Not for use in applications with pets. 2 OPEN THE SENSOR 1. Turn the arrow to point to the Unlock symbol. 2. Press firmly on housing latch. 3. Gently separate the front and rear housing. DT8050A-SN_step2-ii 3 MOUNT THE SENSOR #6 (3.5 mm) #6 x 1 1/4" (3.5 mm x 32 mm) • [A] = Wall mounting holes. • [B] = Corner mounting holes. • The rear tamper plate MUST be mounted to a stud, solid wood, or with a robust wall anchor. DT8050A-SN_step3-ii SENSOR COMPONENTS AND SETTINGS Anti-mask Enabled ON MAX *Look Down Enabled MW SENSITIVITY ON PULL TO DISABLE LOOK DOWN ON OFF LED ANTI-MASK HIGH TRAFFIC INHIBIT MIN MW SENSITIVITY *Factory default WIRE THE SENSOR 22-20 AWG (0.31-0.52mm2) Polling Loop 9 - 13V Pk - PK V+ DT8050A-SN_step5-ii -2- OFF LED *Anti-mask Disabled MAX Microwave Range Adjustment DT8050A-SN_step4-ii Look Down Disabled 6 WALK TEST THE SENSOR AND ADJUST AS NEEDED Walk Test Reset MAX 30 sec MIN MW SENSITIVITY < 4’ (1.2m) 10 ON 45 20 30 1/2 sec. hold 4x DT8050A-SN_step6-ii ON OFF LED Power Up Walk Test Normal Trouble Anti-Mask Red Slow Blink ON Alarm ON Alarm Fast Blink OFF Yellow OFF OFF Fast Blink ON ON Microwave Microwave 1. Apply power to the sensor. Initialization is complete when the LED Green OFF ON PIR ON PIR OFF stops flashing slowly (about 30 seconds). 2. Turn the microwave sensitivity counterclockwise to reduce the microwave range (minimum = 16.4’ / 5m) and close the sensor. 3. Walk through the detection area and observe the LED. 4. Adjust the microwave range as necessary to meet installation requirements. OFF Walk test mode is active for 10 minutes, then automatically exits test mode, disables the LED and enters normal operation mode. For an additional 10 minute walk test, enable walk test mode again with the flashlight feature: Note: During power up and walk test modes the LED is active regardless of the LED Enable/Disable DIP switch setting. Flashlight Feature: 1. Use a flashlight with a bright light beam, and stand within 4’ (1.2 m) of the sensor. 2. Swing the light beam past the sensor IR window 3-5 times, holding the beam on the window for 0.5 second each pass. < 4’ (1.2m) 1/2 sec. hold 4x The flashlight feature is only available for the first 24 hours after power up. DETECTION PATTERNS Top View Side View 40’ 12 m 7’6” 2.3 m 33’ 10 m 7’ 13’ 20’ 27’ 33’ 40’ 46’ 53’ 2 m 4 m 6 m 8 m 10 m 12 m 14 m 16 m 27’ 8m A B 20’ 6m 13’ 4m Zones 7’ 2m PLAN VIEW ALL ZONES 2 Look-down B 12 Lower C 10 Intermediate D 36 Long 7’ 2m 13’ 4m 20’ 6m 27’ 8m 33’ 10 m 40’ 12 m 0 7’ 13’ 20’ 27’ 33’ 40’ 46’ 53’ 2 m 4 m 6 m 8 m 10 m 12 m 14 m 16 m -3- TROUBLESHOOTING PROGRAM THE SENSOR This sensor is a serial number device. Refer to the control panel’s manual for instructions on registering devices and programming. For all V-Plex® panels, program the sensor Zone Type as INT FOLLOWER 04 and the INPUT TYPE as “06” (for SL - Serial Polling Device). If using a Smart V-Plex® panel, program the sensor to Standard mode [press “0” (No)] or SMART CONTACT mode [press “1” (Yes)]. Standard Mode: The sensor includes a selectable High Traffic Inhibit (HTI) feature. This feature reduces bus traffic with a randomized delay (from 5 – 15 seconds) between alarm signals after an alarm and restoral signal is sent. In applications where this delay is not necessary, set DIP Switch 1 to OFF. IMPORTANT: If using the Anti-Mask feature, the sensor MUST be programmed to Standard Mode. Smart Contact Mode: In the Smart Contact mode, the sensor automatically reduces bus traffic by not sending alarm signals when disarmed. ALL modes: Tamper, self-test failures and anti-mask1 signals are sent without delays. 1Anti-mask signals are only sent when Anti-mask is enabled (DIP switch 2 ON), except during Microwave Walk Test mode. See step 6. Red LED Yellow LED NORMAL Off Off Mask1 Off Flashing TROUBLE* Self-Test Failure2 Flashing Off *TROUBLE CONDITIONS: Mask condition: Sensor IR window is blocked or masked. Self-Test Failure conditions: • Microwave supervision failure: The sensor is operating in PIR mode only. • PIR self-test failure: The sensor is disabled. • Temperature compensation failure: The temperature compensation is disabled. Depending on the Trouble condition, take the following corrective actions: • Verify the sensor is not blocked or masked. • Cycle power to the sensor. • Walk test the sensor. If the Trouble condition does not clear, replace the sensor. SPECIFICATIONS Range: 53’ x 72’ / 16 m x 22 m Wall Mounting Height: 6’9” - 8’9” (2.1 m - 2.7 m); Optimal 7’6” (2.3 m) Power: 9.0-13V PK – PK at polling loop terminals; (UL: 9.5-15VDC); 4 mA maximum. Tampers: Cover & Wall Microwave Frequencies: 10.525 GHz RFI Immunity: 20V/m 10-1000MHz, 15V/m 1000-2700MHz PIR White Light Immunity: 6,500 Lux typical Fluorescent light filter: 50 Hz / 60 Hz. Operating Temperature: 14° to 131° F / -10° to 55° C Relative Humidity: 5 to 93% (UL tested at 93%); non-condensing Temperature Compensation: Advanced Dual Slope Dimensions: 4.57” H x 2.76” W x 1.69” D / 11.6 cm H x 7.0 cm W x 4.3 cm D Weight: 5 oz / 142 g (net weight) LED OPERATION The LED can be enabled in several ways: − After power up mode the LED is enabled for 10 minutes (DIP switch 3 ON or OFF). − Remove and replace the front cover to enable the LED for 10 minutes (DIP switch 3 ON or OFF). − Set DIP switch 3 ON (LED Enable); LED remains enabled until disabled (switch 3 OFF). [Exception: When programmed to Smart Contact mode and the system is armed, the LED is always disabled.] − Remote LED Enable. [If using a Smart V-Plex® panel, a Remote LED Enable feature may be available, which allows remote enabling of the LED if DIP switch 3 is OFF. (Refer to the Burglary Walk-Test section in the control panel’s manual.) Using this method, the LED remains enabled while the panel is in the burglary walk test mode.] ACCESSORIES SMB-10* (P/N 0-000-110-01) SMB-10C* (P/N 0-000-111-01) SMB-10T* (P/N 0-000-155-01) Cable* (P/N 1103) Cable* (P/N 1104) Cable* (P/N 1106) MASK CONDITION Normal Anti-Mask Condition The sensor uses Active Infrared (AIR) technology to detect masking. The sensor signals a mask condition when a variety of materials and reflective objects are placed within 2 inches (50mm) in front of the sensor. To avoid false mask alarms, follow the mounting guidelines shown in Step 1. Cable* (P/N 1107) * Not evaluated by UL. Clearing an Anti-Mask Condition When most masking materials or objects are removed, the anti-mask condition will be cleared after several seconds. When the cause of the anti-mask condition is any type of spray or paint coating applied to the window, the window must be replaced before the anti-mask condition can be cleared. After replacing the window, perform a walk test on the sensor. -4- Swivel Mount Bracket Swivel Mount Ceiling Bracket Swivel Mount Bracket w/Tamper General purpose, Solid 22 AWG, 4 conductor General purpose, Stranded 22 AWG, 4 conductor General purpose, Solid 22 AWG, 6 conductor General purpose, Stranded 22 AWG, 6 conductor APPROVAL LISTINGS FCC part 15, Class B verified IC ICES-003, Class B verified UL 639 ULC S306-03 SIA-PIR-01 Passive Infrared detector standard features for false alarm immunity. Product must be tested at least once each year. All wiring must be in accordance with: the National Electrical Code (ANSI/NFPA70); the Canadian Electrical Code, Part I (where applicable); UL681, Standard for Installation and Classification of Burglar and Holdup Alarm Systems; ULCS302, Standard for Installation and Classification of Burglar Alarm Systems for Financial and Commercial Premises, Safes and Vaults; ULC-S310, Standard for Installation and Classification of Residential Burglar Alarm Systems; local codes and the authorities having jurisdiction. The products are intended to be powered by a power-limited output of a UL/CUL Listed Burglar Alarm control unit, or via a Listed UL603/ULC-S318 power-limited power supply that provides 4 hours of standby power. The sensor must be mounted indoors, within the protected premises, and on a wooden stud, solid wood or with a robust wall anchor. UL Notes: All interconnecting devices must be UL Listed. The anti-mask feature has not been evaluated by UL. • • • • • FCC Notes:This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. FEDERAL COMMUNICATIONS COMMISSION STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. CLASS B DIGITAL DEVICE STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient the receiving antenna until interference is reduced or eliminated. • Move the radio or television receiver away from the receiver/control. • Move the antenna leads away from any wire runs to the receiver/control. • Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits. • Consult the dealer or an experienced radio/TV technician for help. INDUSTRY CANADA CLASS B STATEMENT This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. FCC / IC STATEMENT This device complies with Part 15 of the FCC Rules, and Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d’Industrie Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception indésirable. -5- REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM. For patent information, see www.honeywell.com/patents For the latest documentation and online support information, please go to: http://www.security.honeywell.com/hsc/resources/MyWebTech/ For the latest U.S. warranty information, please go to: www.honeywell.com/security/hsc/resources/wa or Please contact your local authorized Honeywell representative for product warranty information. 2017 Honeywell International Inc. Honeywell, V-Plex and DUAL TEC are registered trademarks of Honeywell International Inc. 2 Corporate Center Drive, Suite 100 All other trademarks are the properties of their respective owners. All rights reserved. P.O. Box 9040, Melville, NY 11747 www.honeywell.com/security P/N 800-23448-1 07/17 Rev A
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Format : application/pdf Creator : e311757 Title : Microsoft Word - 800-23448-1_DT8050A-SN_ii Create Date : 2017:11:08 08:00:07 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2018:01:03 10:45:36+08:00 Metadata Date : 2018:01:03 10:45:36+08:00 Producer : GPL Ghostscript 8.15 Document ID : uuid:919b20f4-3d78-4dea-8b50-1a0e31a1ef64 Instance ID : uuid:e7218974-d9e4-4ec3-a3ad-31a1801b4cda Has XFA : No Page Count : 6 Author : e311757EXIF Metadata provided by EXIF.tools