Honeywell 202151TXR Thermostat User Manual E527 Datasheet v1 2 DS

INNCOM International Inc. Thermostat E527 Datasheet v1 2 DS

Manual.pdf

Download: Honeywell 202151TXR Thermostat User Manual E527 Datasheet v1 2 DS
Mirror Download [FCC.gov]Honeywell 202151TXR Thermostat User Manual E527 Datasheet v1 2 DS
Document ID1806069
Application IDopolCTevrGumONzT95BZzg==
Document DescriptionManual.pdf
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize68.41kB (855132 bits)
Date Submitted2012-10-02 00:00:00
Date Available2012-10-02 00:00:00
Creation Date2012-10-01 08:39:48
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2012-10-01 09:26:38
Document TitleMicrosoft Word - E527 Datasheet v1.2 DS.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: mahussain

Confidential
Copyright © 2012 INNCOM
e527 Datasheet
Overview
Like the larger e528, the compact, low profile e527 thermostat takes advantage of
component end-of-life to redesign hardware and produce a more efficient, lower cost
device. With onboard radio and RS485 connection and an added CDS light sensor, the
e527 maintains its position as an integral part of the INNCOM Integrated Room
Automation System (IRAS) and a property’s Energy Management System (EMS).
Features
In an EMS, the e527 controls room heating and cooling using occupancy data collected
from motion detectors and door switches and can be networked to the property’s
central management system. As an IRAS device, the e527 can communicate with
devices within a room and function as a room gateway device towards the mesh network.
Figure 1 E527
•
British gang mounting (American gang mounting with optional frame)
•
Accurate temperature measurement +/- 1 degree F
•
External temperature sensor support
•
Motion sensor for occupancy detection
•
RF transceiver (onboard 802.15.4, 2.4GHz radio) for wireless guestroom and backhaul network
communications
•
RS485 for wired backhaul network communications
•
Photo sensor for light level detection
Installation Requirements
The e527 must be located on a partitioning interior wall, approximately 5' (1.5 m) above the floor, in a site of
average temperature. It is important to ensure that the thermostat is located away from direct sunlight or radiant
heat, air discharge grilles, stairwells, outside doors, steam or water pipes, warm air stacks, unheated/uncooled
areas, or sources of electrical interference. The unit should not be placed on an outside wall or behind a door.
The e527 is designed to be mounted on a standard British-style single-gang electrical box. For use with an
American box, the e527 can be installed in an optional frame by means of two screws. Screws for attaching the
optional frame and mounting the e527 are included. The device is shipped with a clear clamshell dust cover.
E527 Datasheet
Page 2 of 7
Headers
Figure 2 E527 Front/Back and External Headers
H1
H2
H3
H4
H5
H6
H7
H8
H9
ICP microprocessor programming
Humidity sensor
System interconnect
PIR sensor
ES1
RS485 network header (see pinout below)
System 5 header (see pinout below)
System interconnect
External temperature control sensor (see pinout below)
H6 Pinout
Pin
Function
Comment
Common
GND
12VDC
Min
S5bus
10V
12V
14V
Communication bus
Dry Input
Input
RS485B
RS485 Twisted Pair
RS485A
RS485 Twisted Pair
Nom
Max
E527 Datasheet
Page 3 of 7
H7 Pinout
Pin
Function
Comment
Common
GND
12VDC
Min
S5bus
10V
12V
14V
Communication bus
Nom
Max
H9 Pinout
Pin
Function
Comment
Common
GND
Common
External temp sensor
GND
Motion Detection
The optional motion detector available on the e527 works in conjunction with the electronic door lock to
determine room occupancy. If the door lock reports that the door has opened and closed and no motion is
detected in the room for a set number of minutes, the e527 engages energy conservation setbacks. When motion is
detected, the e527 returns to its occupied state. Also, the e527 reports occupancy changes to the central server.
Figure 3 Motion Sensor Sensitivity
E527 Datasheet
Page 4 of 7
Network Communication
INNCOM employs a Deep Mesh system to connect guestroom IRAS components to management and monitoring
servers. Because networking infrastructure is embedded in the IRAS devices, command and reporting
information packets can follow multiple network pathways, increasing communication efficiency and reliability
at lower cost. Typically, a Deep Mesh network integrates 50–200 rooms per network segment*. INNCOM
generally uses a wireless radio network, but a Deep Mesh system may be constructed using RS485 networks
(topologies that merge RF and RS485 networks are also possible).
2.4GHz Wireless RF
In a typical RF Deep Mesh network, an 802.15.4-based 2.4GHz radio-equipped IRAS device (most often a
thermostat, such as the e527) acts as a room gateway for communication with the network. Data are propagated
among the network nodes until terminated at edge routers that bridge traffic onto IP (Ethernet) networks towards
the servers. The radio specifications are given in the table below:
Performance
0dB
RF Data Rate
Antenna Type
250kbps
SMT
Indoor Range
Outdoor/ RF line-of-sight range
Transmit Power
70ft
540ft
1mW
Receive Sensitivity
Frequency Band
-94.6dBm
2.4GHz
Encryption
Protocol
Frequency Channels
AES-128
802.15.4
11–26
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
- Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate this equipment.
The network segment size depends on the facility’s layout, expected network traffic, and other environmental considerations.
E527 Datasheet
Page 5 of 7
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to
the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’industrie Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur
de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le
fonctionnement.
RS485
A Deep Mesh RS485 (DM485) network typically uses a CAT5-type wiring wired as a home-run or daisy-chain.
The DM485 network is routed to a dedicated device in each guestroom. This device becomes the room gateway,
which transfers information packets between the DM485 backbone and the in-room network. The in-room
network can be either S5Bus or a local mesh formed with RF. Each DM485 network is operated by a B575
hardware running DM485 software. Refer to the H6 pinout table above for wiring instructions.
Technical Specifications
Power Requirements
Thermostat Measurement Range
Outdoor Air Temperature Display
Display Resolution
Standard Deadband
Degrees C/Degrees F Display
Ambient Operating
Ambient Storage
Dimensions
Approvals
12VDC, 50mA
33 to 99 degrees F (1 to 37 degrees C)
0 to 99 degrees F (-18 to 37 degrees C)
Whole degree F, 0.5 degree C (0.1 degree F in test mode)
2 degrees F (1 degree C) between heating and cooling
Toggle Button located on front display
41 to 149 degrees F (5 to 65 degrees C), 0-95% RH noncondensing
33 to 149 degrees F (1 to 65 degrees C)
3.5” W x 3.5” H x 0.9” D (89 mm x 89 mm x 23 mm)
FCC, CE Mark
Figure 4 E527 Dimensions
E527 Datasheet
Page 6 of 7
Ordering Information
The e527 is available in several operating configurations, all based on the same fundamental hardware platform.
The ordering part numbers (OPN) are formed by a combination of the elements, as shown below.
Assembly
e527
Logic
L0
L1
Description
Final Assembly
201-527
Description
No Radio Logic Board
Radio Logic Board
202-151.L0
202-151.L1
Communications
R0
R1
User Interface
Humidity Sensor
Description
No Humidity Sensor
Humidity Sensor
Description
No Logo
Part Number
203-203.R0
203-203.R1
Description
6 button with PIR and EcoMode
6 button with PIR, without EcoMode
6 button EcoMode only
6 button no PIR, no EcoMode
5 button with PIR and EcoMode
5 button with PIR, without EcoMode
5 button EcoMode only
5 button no PIR, no EcoMode
Logo OPN
Part Number
Description
No RS485
RS485
6PE
6P0
60E
600
5PE
5P0
50E
500
Part Number
Part Number
02-9972
02-9972
02-9972
02-9972
Part Number
02-9463
E527 Datasheet
Logo OPN
Page 7 of 7
Description
INNCOM Logo
Johnson Controls Logo
Housing Color OPN
WH
BK
LA
EA
Description
White
Black
Light Almond
Eagle Almond
For American gang installation, add mounting plate 53-6092. Use wiring harness 62-1462 for the RS485 connection
and 62-1465 for S5 and external temperature sensor.
Document Revision History
Revision
0.1
0.2
0.3
0.4
1.0
1.1
Date Issued
01-Jun-2012
05-Jun-2012
20-Jun-2012
09-Jul-2012
09-Jul-2012
07-Sep-2012
Reason
First Draft
Incorporated comments from AE review
Incorporated R&D review comments
Incorporated RS485 Deep Mesh information
Finalized for release
Added FCC language change

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2012:10:01 08:39:48Z
Modify Date                     : 2012:10:01 09:26:38-04:00
Page Count                      : 7
Producer                        : GPL Ghostscript 8.15
Creation Date                   : 2012:10:01 08:39:48Z
Mod Date                        : 2012:10:01 09:26:38-04:00
Author                          : mahussain
Metadata Date                   : 2012:10:01 09:26:38-04:00
Title                           : Microsoft Word - E527 Datasheet v1.2 DS.doc
Creator                         : mahussain
EXIF Metadata provided by EXIF.tools
FCC ID Filing: GTC202151TXR

Navigation menu