Honeywell 51306343 51306343 User Manual Ext Temp Pro Install guide

Honeywell International Inc. 51306343 Ext Temp Pro Install guide

Contents

Ext Temp Pro Install guide

Download: Honeywell 51306343 51306343 User Manual Ext Temp Pro Install guide
Mirror Download [FCC.gov]Honeywell 51306343 51306343 User Manual Ext Temp Pro Install guide
Document ID996059
Application IDCAXa66gATBJTLe2eTNlu4g==
Document DescriptionExt Temp Pro Install guide
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize36.77kB (459669 bits)
Date Submitted2008-09-05 00:00:00
Date Available2008-09-05 00:00:00
Creation Date2008-09-04 12:48:50
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2008-09-04 12:48:50
Document TitleExt Temp Pro Install guide

Honeywell Proprietary
and Confidential
51121312
REVISIONS
AT8
OneWireless
Extended Temperature Multinode
Professional Installation Guide
Honeywell Industrial Automation and Control
Ft. Washington, Pennsylvania
NOTICE – HONEYWELL INTERNATIONAL, INCORPORATED
TRADE SECRET - PROPRIETARY
Proprietary Notice:
This document and the information contained herein are confidential to, and the property of Honeywell, Inc. This
document and the information contained herein is made available only to employees of Honeywell, for the sole
purpose of conducting Honeywell's business. This document, and the information contained herein, shall be
maintained in strictest confidence; shall not be copied in whole or in part; and shall not be disclosed or distributed
to persons who are not employees of Honeywell, and for whom such information is not necessary in connection
with their assigned responsibilities. Upon request, or when the employee in possession of this document no longer
has need for this document for the authorized Honeywell purpose, this document shall be returned to the
employee's manager. There shall be no exceptions to the terms and conditions set forth herein except as
authorized in writing by the responsible Honeywell Vice President.
PRELIMINARY
FCF:
OneWireless Extended Temperature Multinode
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8, 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 1 of 36
Honeywell Proprietary
and Confidential
51121312
REVISIONS
AT8
APPROVAL SIGNATURES
_________________________________________________________________
Soroush Amidi, Product Marketing
Date
_________________________________________________________________
William Osei-Bonsu, Hardware Engineering
Date
_________________________________________________________________
David Shipley, Agency Compliance
Date
Revision Record
Revision
AT6
FCF:
Date
03-JUL-2008
Purpose/Distribution
Draft for Peer Review and signature sign off
OneWireless Extended Temperature Multinode
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8, 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 2 of 36
Honeywell Proprietary
and Confidential
AT8
51121312
REVISIONS
TABLE OF CONTENTS
DESIGNATION, SCOPE AND PREFACE........................................................................................... 6
1.1
DESIGNATION ..................................................................................................................................... 6
1.1.1 Model Numbers and Revisions :..................................................................................................6
1.2
SCOPE ............................................................................................................................................... 6
1.3
PREFACE ........................................................................................................................................... 6
1.4
ABBREVIATIONS & DEFINITIONS ........................................................................................................... 7
2.1
3.1
FEDERAL COMMUNICATION COMMISSION (FCC) ........................................................................ 8
FCC COMPLIANCE STATEMENTS ......................................................................................................... 8
INDUSTRY CANADA (IC).................................................................................................................... 8
IC COMPLIANCE STATEMENTS............................................................................................................. 8
RF SAFETY STATEMENT: ................................................................................................................. 9
FCC AND INDUSTRY CANADA (IC) IDENTIFICATION NUMBERS:.............................................. 10
5.1
5.2
6.1
6.2
6.3
7.1
7.2
8.1
8.2
8.3
8.4
8.5
8.6
8.7
FCC IDENTIFICATION NUMBERS: ....................................................................................................... 10
INDUSTRY CANADA IDENTIFICATION NUMBERS: .................................................................................. 10
INTENDED COUNTRY USAGE ........................................................................................................ 11
NORTH AMERICA ......................................................................................................................... 11
AUSTRALIA AND NEW ZEALAND................................................................................................ 11
EUROPEAN UNION....................................................................................................................... 11
MULTINODE GENERAL DESCRIPTION.......................................................................................... 12
INTENDED USE ................................................................................................................................. 12
MULTINODE DEVICE DIAGRAMS ......................................................................................................... 12
PRODUCT SPECIFICATIONS........................................................................................................... 13
FREQUENCY HOPPING SPREAD SPECTRUM (DSSS) RADIO, 2.4GHZ.................................................. 13
FREQUENCY HOPPING SPREAD SPECTRUM (FHSS) RADIO, 2.4GHZ .................................................. 14
IEEE 802.11A/B/G (WI-FI) RADIOS .................................................................................................. 15
MULTINODE USER ENVIRONMENT ...................................................................................................... 16
MULTINODE POWER SPECIFICATIONS ................................................................................................ 16
WEIGHT ........................................................................................................................................... 16
DIMENSIONS ..................................................................................................................................... 17
CABLES ............................................................................................................................................. 18
9.1
9.2
EXTERNAL INTERFACE CABLES .......................................................................................................... 18
ANTENNA CABLES............................................................................................................................. 19
10
ANTENNA LIGHTNING ARRESTORS ............................................................................................. 19
10.1
10.2
11
FCF:
FOR USE WITH INTEGRAL OR REMOTE ANTENNA(S) ............................................................................ 19
FOR USE WITH REMOTE ANTENNA(S) ................................................................................................. 19
APPROVED ANTENNA TYPES/GAINS ........................................................................................... 20
OneWireless Extended Temperature Multinode
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8, 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 3 of 36
Honeywell Proprietary
and Confidential
11.1
11.2
AT8
51121312
REVISIONS
DSSS, FHSS 2.4GHZ RADIO: ......................................................................................................... 20
802.11A/B/G ACCESS POINT AND BRIDGE (MESH) RADIO ................................................................... 21
12
EQUIVALENT ISOTROPICALLY RADIATED POWER (EIRP)........................................................ 22
13
EIRP LIMITS, DSSS 2.4GHZ RADIO ................................................................................................ 23
14
EIRP LIMITS, FHSS 2.4GHZ RADIO.................................................................................................24
15
EIRP LIMITS, 802.11A (5.8GHZ) ACCESS POINT AND BRIDGE RADIO...................................... 25
16
EIRP LIMITS, 802.11A (5.4GHZ) ACCESS POINT AND BRIDGE RADIO...................................... 26
17
EIRP LIMITS, 802.11B/G (2.4GHZ) ACCESS POINT AND BRIDGE RADIO .................................. 27
18
SETTING POWER AND COUNTRY CODE: DSSS-FH RADIO ....................................................... 28
19
SETTING POWER & COUNTRY CODE: 802.11 ACCESS POINT & BRIDGE RADIO .................. 29
19.1
POWER SETTING REFERENCE TABLE, 802.11 ACCESS POINT & BRIDGE RADIO:................................. 31
20
RF SAFETY, MAXIMUM PERMISSIBLE EXPOSURE (MPE) STATEMENT ................................... 32
21
AGENCY COMPLIANCE ................................................................................................................... 33
21.1
RADIO AND EMC CERTIFICATIONS .................................................................................................... 33
21.1.1
Federal Communication Commission (FCC)......................................................................... 33
21.1.2
Industry Canada (IC) ............................................................................................................. 33
21.1.3
European Telecommunications Standards Institue (ETSI) ................................................... 33
21.1.4
Australian communications and media authority (ACMA)..................................................... 33
21.2
PRODUCT SAFETY AGENCY CERTIFICATIONS ..................................................................................... 34
21.2.1
Canadian Standards Association (CSA) ............................................................................... 34
21.2.2
Factory Mutual (FM) .............................................................................................................. 35
21.2.3
European ATEX Certification (ATEX).................................................................................... 36
21.3
EUROPEAN UNION CERTIFICATION (CE-MARK)................................................................................... 36
22
FCF:
REFERENCE DOCUMENTS ............................................................................................................. 36
OneWireless Extended Temperature Multinode
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8, 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 4 of 36
Honeywell Proprietary
and Confidential
AT8
51121312
REVISIONS
LIST OF FIGURES
Figure 1 –Diagram of Multinode Unit showing various external attributes ____________________________ 12
Figure 2 – Dimension of the Multinode Device _________________________________________________ 17
LIST OF TABLES
Table 1 – Assembly Number and Revision........................................................................................................... 6
Table 2 –Table of Abbreviations and Definitions .................................................................................................. 7
Table 3 – Specifications of DSSS Radio in Multinode Device. ........................................................................... 13
Table 4 – Specifications of FHSS Radio in Multinode Device. ........................................................................... 14
Table 5 – IEEE 802.11a/b/g Wi-Fi Radio Specifications..................................................................................... 15
Table 6 – Specifications User Environment Multinode Device. .......................................................................... 16
Table 7 – Power Specifications Multinode Device. ............................................................................................. 16
Table 8 – External Cable Specification for Multinode Device. ............................................................................ 18
Table 9 - Antenna Cable Specifications for Multinode Device............................................................................ 19
Table 10 – Lightning Arrestor Specifications for Integral Antenna(s) ................................................................. 19
Table 11 – Lightning Arrestor Specifications for Remote Antenna(s)................................................................. 19
Table 12 – Approved Antenna Types/Gains, DSSS, FHSS Radio ..................................................................... 20
Table 13 – Approved Antenna Types/Gains, 802.11a/b/g Radios ..................................................................... 21
Table 14 – EIRP Limits, DSSS 2.4GHz Radio .................................................................................................... 23
Table 15 - EIRP Limits, FHSS 2.4GHz Radio ..................................................................................................... 24
Table 16 – EIRP Limits, 802.11a (5.8GHz) Radios ............................................................................................ 25
Table 17 – EIRP Limits, 802.11a (5.4GHz) Radios ............................................................................................ 26
Table 18 – EIRP Limits, 802.11b/g (2.4GHz) Radios ......................................................................................... 27
Table 19: 802.11 Radio Power Setting Reference.............................................................................................. 31
FCF:
OneWireless Extended Temperature Multinode
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8, 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 5 of 36
Honeywell Proprietary
and Confidential
AT8
51121312
REVISIONS
DESIGNATION, SCOPE AND PREFACE
1.1
Designation
HONEYWELL ONEWIRELESS MULTINODE DEVICE.
1.1.1
Model Numbers and Revisions :
This document is valid for the following Multinode assembly number:
MULTINODE EXTENDED TEMPERATURE
Model
Hardware Assembly
Description
Number
# / Revision
Multinode Extended Temperature – 802.11a/b/g and
WNMF 51153884-200 / C
2.4GHz FHSS Radios
WNMS
51153884-201 / C
Multinode Extended Temperature – 802.11a/b/g and
2.4GHz DSSS Radios
Table 1 – Assembly Number and Revision
1.2 Scope
This document outlines professional installation requirements for the Honeywell Multinode
Device for the Honeywell OneWireless Network. Professional installation is required to
comply with certification agency and legal requirements. This document must be adhered to
for all installations of the Honeywell OneWireless Multinode device.
1.3 Preface
This manual covers professional installation of the optional external antennas for use with the
Honeywell OneWireless Multinode device. Since this device requires manual power limit
settings for use with the higher gain antennas, it is classified by the FCC as a professional
install device. To be in compliance with FCC requirements, the radio must be installed with
one of several approved antenna types listed in this document. The Honeywell OneWireless
Multinode device works in conjunction with Honeywell XYR5000 and XYR6000 wireless
sensors and Wi-Fi access point devices. See the Reference Documents section, for general
information on overall system implementation, configuration, and management of the
multimode.
FCF:
OneWireless Extended Temperature Multinode
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8, 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 6 of 36
Honeywell Proprietary
and Confidential
51121312
REVISIONS
AT8
1.4 Abbreviations & Definitions
The term Honeywell Multinode Device (or simply Multinode) will be used to describe the
composite unit which includes the Honeywell DSSS or FHSS Radio Board, 3eTI Mesh Board,
Power Supply board, and all subassemblies housed inside the Multinode enclosure.
ACMA
ATEX
AWG
Co-located
COTS
CSA
DFS
DSSS
EMC
ETSI
EU
FCC
FHSS
FM
IC
IEEE
IR
IrDA
LED
MPE
MTBF
NEMA
PCB
PCI
RAM
RJ-45
RPN
SQA
Wi-Fi
WNSIA
Australian Communications and Media Authority
Potentially Explosive Atmospheres Directive
American Wire Gauge
Two or more radios transmitting simultaneously and with less than
20cm of separation distance.
Commercial Off-The-Shelf
Canadian Standards Association
Dynamic Frequency Selection
Direct Sequence Spread Spectrum
Electromagnetic Compatibility
European Telecommunications Standards Institute
European Union
Federal Communications Committee
Frequency-Hopping Spread Spectrum
Factory Mutual
Industry Canada
Institute of Electrical and Electronics Engineers
Infrared
Infrared Data Association
Light Emitting Diode
Maximum Permissible Exposure
Mean Time Between Failures
National Electrical Manufacturers Association
Printed Circuit Board
Peripheral Components Interconnect
Random Access Memory
Registered Jack-45
Reverse Polarity N-type
Supplier Quality Assurance
Wireless Local Area Network based on IEEE 802.11 Specifications
Wireless Network for Secure Industrial Application
Table 2 –Table of Abbreviations and Definitions
FCF:
OneWireless Extended Temperature Multinode
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8, 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 7 of 36
Honeywell Proprietary
and Confidential
AT8
51121312
REVISIONS
FEDERAL COMMUNICATION COMMISSION (FCC)
2.1
FCC Compliance Statements
This device complies with Part 15 of FCC Rules and Regulations. Operation is
subject to the following two conditions: (1) This device may not cause harmful
interference and (2) this device must accept any interference received, including
interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radiofrequency
energy and, if not installed and used in accordance with these instructions, may
cause harmful interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
Intentional or unintentional changes or modifications must not be made to the
Multinode unless under the express consent of the party responsible for
compliance. Any such modifications could void the user’s authority to operate the
equipment and will void the manufacturer’s warranty.
INDUSTRY CANADA (IC)
3.1
IC Compliance Statements
To reduce potential radio interference to other users, the antenna type and its gain
should be so chosen that the equivalent isotropic radiated power (EIRP) is not
more than that permitted for successful communication.
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
This Class A digital apparatus complies with Canadian ICES-003.
French: Cet appareil numérique de la classe A est conforme à la norme NMB-003
du Canada.
FCF:
OneWireless Extended Temperature Multinode
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8, 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 8 of 36
Honeywell Proprietary
and Confidential
AT8
51121312
REVISIONS
RF Safety Statement:
To comply with FCC’s and Industry Canada’s RF exposure requirements, the following
antenna installation and device operating configurations must be satisfied.
Remote Point-to-Multi-Point antenna(s) for this unit must be fixed and mounted
on outdoor permanent structures with a separation distance between the
antenna(s) of greater than 20cm and a separation distance of at least 20cm from
all persons.
Remote Fixed Point–to-Point antenna(s) for this unit must be fixed and mounted
on outdoor permanent structures with a separation distance between the
antenna(s) of greater than 20cm and a separation distance of at least 100cm from
all persons.
Furthermore, when using integral antenna(s) the Multinode unit must not be colocated with any other antenna or transmitter device and have a separation
distance of at least 20cm from all persons.
FCF:
OneWireless Extended Temperature Multinode
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8, 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 9 of 36
Honeywell Proprietary
and Confidential
5.1
5.2
FCF:
51121312
REVISIONS
AT8
FCC and Industry Canada (IC) Identification Numbers:
FCC Identification Numbers:
•
Honeywell Multinode DSSS Radio
o Limited Modular Approval
o Federal Communication Commission Identification: S57 - 51306343
•
Honeywell Multinode FHSS Radio
o Limited Modular Approval
o Federal Communication Commission Identification: S57 - WNMNFHSS
•
Honeywell Extended Temperature Multinode 802.11a/b/g Radio
o Limited Modular Approval
o Federal Communication Commission Identification: S57 - DCMA-82
Industry Canada Identification Numbers:
•
Honeywell Multinode DSSS Radio
o Limited Modular Approval
o Industry Canada Identification: 573I - 51306343
•
Honeywell Multinode FHSS Radio
o Limited Modular Approval
o Industry Canada Identification: 573I - WNMNFHSS
•
Honeywell Extended Temperature Multinode 802.11a/b/g Radio
o Limited Modular Approval
o Industry Canada Identification: 573I - DCMA82
OneWireless Extended Temperature Multinode
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8, 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 10 of 36
Honeywell Proprietary
and Confidential
51121312
REVISIONS
AT8
INTENDED COUNTRY USAGE
6.1
NORTH AMERICA
Country
UNIIITED STATES
CANADA
6.2
ISO 3166 2 letter code
US
CA
AUSTRALIA AND NEW ZEALAND
Country
AUSTRALIA
NEW ZEALAND
6.3
EUROPEAN UNION
Country
Austria
Belgium
Bulgaria
Cyprus
Czech Republic
Denmark
Estonia
Finland
France
Germany
Greece
Hungary
Iceland
Ireland
Italy
FCF:
ISO 3166 2 letter code
AU
NZ
ISO 3166
2 letter code
AT
BE
BG
CY
CZ
DK
EE
FI
FR
DE
GR
HU
IS
IE
IT
Country
Latvia
Liechtenstein
Lithuania
Malta
Netherlands
Norway
Poland
Portugal
Romania
Slovakia
Slovenia
Spain
Sweden
Switzerland
United Kingdom
ISO 3166
2 letter code
LV
LI
LT
MT
NL
NO
PL
PT
RO
SK
SI
ES
SE
CH
BG
OneWireless Extended Temperature Multinode
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8, 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 11 of 36
Honeywell Proprietary
and Confidential
AT8
51121312
REVISIONS
MULTINODE GENERAL DESCRIPTION
7.1 Intended Use
The Multinode unit is a key component of the Honeywell Wireless Network for Secure
Industrial Application (WNSIA). It provides wireless mesh connectivity for wireless sensor
networks and wireless worker appliances. The Multinode uses powerful radios to
communicate with gateway devices connected to a wired DCS network, and a low-powered
radio to communicate with wireless sensors. The Multinode unit consists of two types of
radios: a sensor radio for communication with XYR 6000 transmitters and IEEE 802.11a/b/g
radios for mesh (bridge) network and communication with mobile access point (client)
devices.
7.2
Multinode Device Diagrams
Figure 1 shows the unit-level drawing of the Multinode Device. All cables exit the unit via a ¾”
conduit hub. The conduit hub allows end user to land conduit on the Multinode Device. Figure
1 shows the Multinode and all of external interfaces.
Figure 1 –Diagram of Multinode Unit showing various external attributes
FCF:
OneWireless Extended Temperature Multinode
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8, 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 12 of 36
Honeywell Proprietary
and Confidential
AT8
51121312
REVISIONS
PRODUCT SPECIFICATIONS
8.1
Direct Sequence Spread Spectrum (DSSS) Radio, 2.4GHz
Warning! The Multinode unit must be Professionally Installed in accordance with the
requirements specified in this document. See Section 10, for professional installation
maximum power setting requirements. Only the specified power settings, antenna types and
gains and cable lengths (attenuation) as outlined in this document are valid for Multinode
installations.
Item
Specification
Wireless Standard
Data Rates and Modulation
Frequency Band
Transmit Power
Receive Sensitivity
(typical)
Direct Sequence Spread Spectrum 2.4GHz
Data Rate: 250kbps
Modulation: OQPSK – DSSS
2,405 – 2,475MHz
Maximum: 19dBm
(Maximum transmit power will vary by channel and individual country
regulations.
-95dBm
Table 3 – Specifications of DSSS Radio in Multinode Device.
FCF:
OneWireless Extended Temperature Multinode
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8, 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 13 of 36
Honeywell Proprietary
and Confidential
8.2
AT8
51121312
REVISIONS
Frequency Hopping Spread Spectrum (FHSS) Radio, 2.4GHz
Warning! The Multinode unit must be Professionally Installed in accordance with the
requirements specified in this document. See Section 10, for professional installation
maximum power setting requirements. Only the specified power settings, antenna types and
gains and cable lengths (attenuation) as outlined in this document are valid for Multinode
installations.
Item
Specification
Wireless Standard
Data Rates and Modulation
Frequency Band
Transmit Power
Receive Sensitivity
(typical)
Frequency Hopping Spread Spectrum (FHSS), 2.4GHz
Data Rate: 250kbps
Modulation: Gaussian Frequency Shift Keying (GFSK)
2,402 – 2,482MHz
Maximum: 19dBm
(Maximum transmit power will vary by channel and individual country
regulations.
-98dBm
Table 4 – Specifications of FHSS Radio in Multinode Device.
FCF:
OneWireless Extended Temperature Multinode
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8, 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 14 of 36
Honeywell Proprietary
and Confidential
51121312
REVISIONS
AT8
8.3 IEEE 802.11a/b/G (Wi-Fi) Radios
The Multinode has two IEEE 802.11 radios for implementing client (access point) and mesh
(bridge) networks.
Warning! The Multinode unit must be Professionally Installed in accordance with the
requirements specified in this document. See Section 11, for professional installation
maximum power setting requirements. Only the specified power settings, antenna types and
gains and cable lengths (attenuation) as outlined in this document are valid for Multinode
installations.
Item
Wireless Standards
Specification
IEEE 802.11a/b/g
• 802.11a: 54, 48, 36, 18, 12, 9, 6 Mbps
• 802.11b: 11, 5.5, 2, 1 Mbps
• 802.11g: 54, 48, 36, 18, 12, 9, 6 Mbps
Data Rates
Modulation Technique
802.11 a/b/g: DSSS (DBPSK, DQPSK, CCK), OFDM (BPSK,QPSK, 16-QAM, 64-QAM)
Frequency Bands and
Operating Channels
United States and Canada (FCC and IC):
•
802.11b/g: 2,412 – 2,462MHz, Channels 1 – 11
•
802.11a: 5,745 – 5,825, Channels 149,153,157,161,165
Europe (ETSI):
•
802.11b/g: 2,412 – 2,472MHz, Channels 1 – 13
•
802.11a: 5,500 – 5,700, Channels
100,104,108,112,116,120,124,128,132,136,140
Australia (ACMA):
•
802.11b/g: 2,412 – 2,472MHz, Channels 1 – 13
•
802.11a: 5,745 – 5,825, Channels 149,153,157,161,165
Output Power
(maximum)
802.11a:
+22.5dBm at 6, 9,
12, 18Mbps
+21.5dBm at
36Mbps
+19dBm at 48Mbps
+18dBm at 54Mbps
Receive sensitivity
(typical)
802.11a:
802.11b:
+24.5dBm at 1,2,
5.5, and 11Mbps
802.11g:
+24.5dBm at 6, 9, 12, 18Mbps
+23.5dBm at 36Mbps
+22dBm at 48Mbps
+21dBm at 54Mbps
-91dB@6Mbps, -90dB@9Mbps, -90@12Mbps, -88dB@18Mbps,
-85dB@24Mbps, -82dB@36Mbps, -76dB@48Mbps, -72dB@54Mbps
802.11b:
-97dB@1Mbps, -93dB@2Mbps, -92dB@5.5Mbps, -88dB@11Mbps
802.11g:
-91dB@6Mbps, -90dB@9Mbps, -89@12Mbps, -87dB@18Mbps,
-84dB@24Mbps, -80dB@36Mbps, -76dB@48Mbps, -74dB@54Mbps
Table 5 – IEEE 802.11a/b/g Wi-Fi Radio Specifications.
FCF:
OneWireless Extended Temperature Multinode
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8, 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 15 of 36
Honeywell Proprietary
and Confidential
8.4
51121312
REVISIONS
AT8
Multinode User Environment
Item
Specification
Operating Temperature:
Storage Temperature:
Operating Humidity:
-40 OC to +75 OC
-40 OC to +75 OC
0 to 100% RH
Table 6 – Specifications User Environment Multinode Device.
8.5
Multinode Power Specifications
Item
Operating Voltage:
Power Consumption
(typical):
Specification
20.4Vdc to 26.4Vdc
25W
Table 7 – Power Specifications Multinode Device.
8.6 Weight
The weight of the complete Multinode units shall be 7.0 lb. (3.2 kg) maximum. This weight
does not include the integral antennas or other external accessories.
FCF:
OneWireless Extended Temperature Multinode
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8, 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 16 of 36
Honeywell Proprietary
and Confidential
8.7
AT8
51121312
REVISIONS
Dimensions
Figure 2 – Dimension of the Multinode Device
FCF:
OneWireless Extended Temperature Multinode
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8, 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 17 of 36
Honeywell Proprietary
and Confidential
AT8
51121312
REVISIONS
Cables
9.1 External Interface Cables
Cable Type
Specification
External
CAT5E
Ethernet
Stranded Core
24VDC Power
Ground
Conductor
Note:
•
•
•
Multiconductor,
AWG
AWG10
Qty
Comments/Specification
Routed through conduit hub.
Termination = RJ-45 Modular Plug
Finished Length = 24 inches
Finished Length = 24 inches
Routed through conduit hub
Conductor Color:
Red & Green = 24VDC
White & Black = Common
Drain wire = Chassis potential
Routed through conduit hub
Color = Green or Green with yellow stripes.
Finished length = 24 inches
Finished length is measured from conduit hub to outside tip of cable.
Ground conductor must be attached to product safety protective earth and building steel ground.
All external wiring must be routed through metal conduit.
Table 8 – External Cable Specification for Multinode Device.
FCF:
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 18 of 36
Honeywell Proprietary
and Confidential
51121312
REVISIONS
AT8
9.2
Antenna Cables
Cable
Honeywell
Application
Part #
DSSS, FHSS, 50018278-001
802.11
DSSS, FHSS, 50018278-003
802.11
DSSS, FHSS, 50018278-010
802.11
Cable
Type
400
Series
400
Series
400
Series
Connector
Type
NM – NM
Frequency Length
(GHz)
(m)
2.4/5.8
Loss
(dB)
1.0 / 2.0
NM – NM
2.4/5.8
1.5 / 2.5
NM – NM
2.4/5.8
10
2.5 / 3.5
Table 9 - Antenna Cable Specifications for Multinode Device.
10 Antenna Lightning Arrestors
10.1 For use with Integral or Remote Antenna(s)
Application
Honeywell
Specification
Connector
Part Number
Type
DSSS, FHSS, 51202359-200
50 ohm
NM - NF
802.11
Frequency Attenuation
(GHz)
(dB)
0–6
0.4 (max)
Table 10 – Lightning Arrestor Specifications for Integral Antenna(s)
10.2 For use with Remote Antenna(s)
Application
Honeywell
Specification
Part Number
DSSS, FHSS, 50018279-090
50 ohm
802.11
Connector
Type
NF to NF
Frequency Attenuation
(GHz)
(dB)
0–3
0.4 (max)
NOTE: Depending on application needs, the “integral” arrestors may be used for remote antennas.
Table 11 – Lightning Arrestor Specifications for Remote Antenna(s)
FCF:
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 19 of 36
Honeywell Proprietary
and Confidential
51121312
REVISIONS
AT8
11 Approved Antenna Types/Gains
11.1 DSSS, FHSS 2.4GHz Radio:
Antenna
Type
Antenna
Application
Omni
(integral)
Omni
(integral)
Omni
(integral)
Omni
(remote)
Sector
(remote)
Point to
Multi-Point
Point to
Multi-Point
Point to
Multi-Point
Point to
Multi-Point
Point to
Multi-Point
Manufacturer
Manufacturer
Part Number
PacWireless
OD24M-5
SMARTANT
SMARTANT
SAA04051000
HON04052160
HYPERLINK
HGV-2409U
HYPERLINK
HG2414SP120
Honeywell
Part
Number
51506534101
51506534101
51506534100
50018414001
NA
Beam
Width
Peak
Gain
(dBi)
Freq.
(GHz)
Omni
2.4
Omni
2.4
Omni
2.4
Omni
2.4
120°
14
2.4
Agency
Compliance
FCC, IC,
ETSI, ACMA
FCC, IC,
ETSI, ACMA
FCC, IC,
ETSI, ACMA
FCC, IC,
ETSI, ACMA
FCC, IC,
ETSI, ACMA
Table 12 – Approved Antenna Types/Gains, DSSS, FHSS Radio
FCF:
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 20 of 36
Honeywell Proprietary
and Confidential
51121312
REVISIONS
AT8
11.2 802.11a/b/g Access point and Bridge (Mesh) Radio
Antenna
Type
Antenna
Application
Manufacturer
Manufacturer
Part Number
Honeywell
Part
Number
Beam
Width
Peak
Gain
(dBi)
3.5
Omni
(integral)
Point to MultiPoint
Air802
ANOM245XM
51506534
-200
Omni
5.3
4.0
Omni
(integral)
Omni
(remote)
Omni
(remote)
Omni
(remote)
Sector
(remote)
Sector
(remote)
Sector
(remote)
YAGI
(remote)
DISH
(remote)
DISH
(remote)
Point to MultiPoint
Point to MultiPoint
Point to MultiPoint
Point to MultiPoint
Point to MultiPoint
Point to MultiPoint
Point to MultiPoint
Point to MultiPoint
Fixed Point to
Point
Fixed Point to
Point
SMARTANT
SAA05-220920
51506534
-200
Omni
7.0
HYPERLINK
HGV-2409U
50018414001
Omni
HYPERLINK
HG5412U
NA
Omni
12
HYPERLINK
HG5812U-PRO
NA
Omni
12
HYPERLINK
HG2414SP-120
NA
120°
14
HYPERLINK
HG5417P-090
NA
90°
17
HYPERLINK
HG5817P-090
NA
90°
17
TELEX
5816AB
NA
19°
16.5
HYPERLINK
HG5423D
NA
9°
23
HYPERLINK
HG5824D
NA
9°
24
Freq
(GHz)
Agency
Compliance
2.4
802.11b/g
FCC, IC,
ETSI, ACMA
5.4
802.11a
ETSI
5.8
802.11a
2.4
802.11b/g
FCC, IC,
ACMA
FCC, IC,
ETSI, ACMA
5.4
802.11a
ETSI
5.8
802.11a
2.4
802.11b/g
5.4
802.11a
5.8
802.11a
2.4
802.11b/g
5.4
802.11a
5.8
802.11a
5.8
802.11a
5.4
802.11a
5.8
802.11a
FCC, IC,
ACMA
FCC, IC,
ETSI, ACMA
ETSI
FCC, IC,
ACMA
FCC, IC,
ETSI, ACMA
ETSI
FCC, IC,
ACMA
FCC, IC,
ACMA
ETSI
FCC, IC,
ACMA
Table 13 – Approved Antenna Types/Gains, 802.11a/b/g Radios
FCF:
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 21 of 36
Honeywell Proprietary
and Confidential
51121312
REVISIONS
AT8
12 Equivalent Isotropically Radiated Power (EIRP)
In radio communication systems, Equivalent isotropically radiated power (EIRP), or
alternatively, Effective isotropic radiated power is the amount of power that would have to be
emitted by an isotropic antenna (that evenly distributes power in all directions and is a
theoretical construct) to produce the peak power density observed in the direction of
maximum antenna gain. EIRP can take into account the losses in transmission line and
connectors and includes the gain of the antenna. The EIRP is often stated in terms of
decibels over a reference power level, that would be the power emitted by an isotropic
radiator with an equivalent signal strength. The EIRP allows making comparisons between
different emitters regardless of type, size or form. From the EIRP, and with knowledge of a
real antenna's gain, it is possible to calculate real power and field strength values.
EIRP(dBm) = (Radio Power (dBm)) – (Cable Loss (dB)) + (Antenna Gain(dBi))
Antenna gain is expressed relative to a (theoretical) isotropic reference antenna (dBi).
FCF:
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 22 of 36
Honeywell Proprietary
and Confidential
51121312
REVISIONS
AT8
13 EIRP LIMITS, DSSS 2.4GHz RADIO
Antenna
Type
Omni
Omni
Sector
Freq.
(GHz)
Max.
Ant.
Gain
(dBi)
Min. Cable
Length
(m)
Min.
Cable
Loss
(dB)
Integral
2.4
Remote
2.4
1.0
Remote
2.4
14
1.0
Radio Usage /
Application
Point to
MultiPoint
Point to
MultiPoint
Point to
MultiPoint
Max. Radio
Output
Power (dBm)
Max.
EIRP
(dBm)
Agency/
Country
20
25
FCC, IC
11
ETSI 5, ACMA
19
26
FCC, IC
12
ETSI 5, ACMA
15
28
FCC, IC
13
ETSI 5, ACMA
Notes:
1. The values in the above table have been determined through agency certification testing.
2. Maximum transmit power will vary by channel, data rate, and individual country regulations.
3. The following shall apply for antenna type, frequency range, application/usage and agency/country
compliance:
• Antenna gains above the maximum values shown shall not be used.
• Cable length/loss below the minimum values shown shall not be used.
• Maximum overall radio output power shown shall not be exceeded.
• Maximum EIRP values shown above shall not be exceeded.
4. Beam width, for sector and dish antenna, may range between 0 – 180degress.
5. France restricts outdoor use to 10mW (10dBm) EIRP in the frequency range of 2,454-2,483.5 MHz.
Installations in France must limit EIRP to 10dBm, for operating modes utilizing frequencies in the range
of 2,454 – 2,483.5MHz.
6. Industry Canada Compliance Statement: This device has been designed to operate with the antenna
types listed in this document, and having a maximum gain of 14dBi. Antenna types not included in this
list or having a gain greater than 14dBi are strictly prohibited for use with this device. The required
antenna impedance is 50 ohms.
Table 14 – EIRP Limits, DSSS 2.4GHz Radio
FCF:
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 23 of 36
Honeywell Proprietary
and Confidential
51121312
REVISIONS
AT8
14 EIRP LIMITS, FHSS 2.4GHz RADIO
Antenna
Type
Omni
Omni
Sector
Freq.
(GHz)
Max.
Ant.
Gain
(dBi)
Min. Cable
Length
(m)
Min.
Cable
Loss
(dB)
Integral
2.4
Remote
2.4
1.0
Remote
2.4
14
1.0
Radio Usage /
Application
Point to
MultiPoint
Point to
MultiPoint
Point to
MultiPoint
Max. Radio
Output
Power (dBm)
Max.
EIRP
(dBm)
Agency/
Country
19
24
FCC, IC
14
19
ETSI 5, ACMA
17
24
FCC, IC
12
19
ETSI 5, ACMA
12
25
FCC, IC
19
ETSI 5, ACMA
Notes:
7. The values in the above table have been determined through agency certification testing.
8. Maximum transmit power will vary by channel, data rate, and individual country regulations.
9. The following shall apply for antenna type, frequency range, application/usage and agency/country
compliance:
• Antenna gains above the maximum values shown shall not be used.
• Cable length/loss below the minimum values shown shall not be used.
• Maximum overall radio output power shown shall not be exceeded.
• Maximum EIRP values shown above shall not be exceeded.
10. Beam width, for sector and dish antenna, may range between 0 – 180degress.
11. France restricts outdoor use to 10mW (10dBm) EIRP in the frequency range of 2,454-2,483.5 MHz.
Installations in France must limit EIRP to 10dBm, for operating modes utilizing frequencies in the range
of 2,454 – 2,483.5MHz.
12. Industry Canada Compliance Statement: This device has been designed to operate with the antenna
types listed in this document, and having a maximum gain of 14dBi. Antenna types not included in this
list or having a gain greater than 14dBi are strictly prohibited for use with this device. The required
antenna impedance is 50 ohms.
Table 15 - EIRP Limits, FHSS 2.4GHz Radio
FCF:
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 24 of 36
Honeywell Proprietary
and Confidential
51121312
REVISIONS
AT8
15 EIRP LIMITS, 802.11a (5.8GHz) Access Point and Bridge Radio
Ant.
Type
Radio Usage /
Application
Freq.
(GHz)
Max.
Ant.
Gain
(dBi)
Min.
Cable
Length
(m)
Min.
Cable
Loss
(dB)
Omni
Point to
Multi-Point
Integral
5.8
802.11a
7.0
Omni
Point to
Multi-Point
Remote
5.8
802.11a
12
Sector
Point to
Multi-Point
Remote
5.8
802.11a
17
Yagi
Point to
Multi-Point
Remote
5.8
802.11a
16.5
Dish
Fixed
Pt. to Pt.
Remote
5.8
802.11a
24
Max.
Radio
Output
Power
(dBm)
Max.
EIRP
(dBm)
ProInstall
Power
Setting
Agency/
Country
26
23
24
20
19
15
19
15.5
27
33
30
34
30
34
30
34
30
49
30
10
-5
-3
-11
-15
-22
-15
-22
40
-37
FCC, IC
ACMA
FCC, IC
ACMA
FCC, IC
ACMA
FCC, IC
ACMA
FCC, IC
ACMA
Notes:
1. The values in the above table have been determined through agency certification testing.
2. Maximum transmit power will vary by channel, data rate, and individual country regulations.
3. The following shall apply for antenna type, frequency range, application/usage and agency/country
compliance:
• Antenna gains above the maximum values shown shall not be used.
• Cable length/loss below the minimum values shown shall not be used.
• Maximum overall radio output power shown shall not be exceeded.
• Maximum EIRP values shown above shall not be exceeded.
4. Beam width, for sector and dish antenna, may range between 0 – 180degress.
5. Industry Canada Compliance Statement: This device has been designed to operate with the antenna
types listed in this document, and having a maximum gain of 24dBi. Antenna types not included in this
list or having a gain greater than 24dBi are strictly prohibited for use with this device. The required
antenna impedance is 50 ohms.
Table 16 – EIRP Limits, 802.11a (5.8GHz) Radios
FCF:
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 25 of 36
Honeywell Proprietary
and Confidential
51121312
REVISIONS
AT8
16 EIRP LIMITS, 802.11a (5.4GHz) Access Point and Bridge Radio
Ant.
Type
Radio Usage /
Application
Freq.
(GHz)
Max.
Ant.
Gain
(dBi)
Min.
Cable
Length
(m)
Min.
Cable
Loss
(dB)
Max.
Radio
Output
Power
(dBm)
Max.
EIRP
(dBm)
ProInstall
Power
Setting
Agency/
Country
Omni
Point to
Multi-Point
Integral
5.4
802.11a
7.0
21
28
-14
ETSI
Omni
Point to
Multi-Point
Remote
5.4
802.11a
12
18
28
-10
ETSI
Sector
Point to
Multi-Point
Remote
5.4
802.11a
17
13
28
-22
ETSI
Dish
Fixed
Pt. to Pt.
Remote
5.4
802.11a
23
10
3.8
26
-33
ETSI
Notes:
1. The values in the above table have been determined through agency certification testing.
2. Maximum transmit power will vary by channel, data rate, and individual country regulations.
3. The following shall apply for antenna type, frequency range, application/usage and agency/country
compliance:
• Antenna gains above the maximum values shown shall not be used.
• Cable length/loss below the minimum values shown shall not be used.
• Maximum overall radio output power shown shall not be exceeded.
• Maximum EIRP values shown above shall not be exceeded.
4. Beam width, for sector and dish antenna, may range between 0 – 180degress.
5. Industry Canada Compliance Statement: This device has been designed to operate with the antenna
types listed in this document, and having a maximum gain of 23dBi. Antenna types not included in this
list or having a gain greater than 23dBi are strictly prohibited for use with this device. The required
antenna impedance is 50 ohms.
6. A 10 meter cable must be used with the 23dBi Dish antenna, in order to comply with ETSI Transmit
Power Control (TPC) requirements.
Table 17 – EIRP Limits, 802.11a (5.4GHz) Radios
FCF:
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 26 of 36
Honeywell Proprietary
and Confidential
51121312
REVISIONS
AT8
17 EIRP LIMITS, 802.11b/g (2.4GHz) Access Point and Bridge Radio
Ant.
Type
Radio Usage /
Application
Freq.
(GHz)
Max.
Ant.
Gain
(dBi)
Min.
Cable
Length
(m)
Min.
Cable
Loss
(dB)
Omni
Point to
Multi-Point
Integral
2.4
802.11b/g
4.0
Omni
Point to
Multi-Point
Remote
2.4
802.11b/g
Sector
Point to
Multi-Point
Remote
2.4
802.11b/g
14
Max.
Radio
Output
Power
(dBm)
Max.
EIRP
(dBm)
ProInstall
Power
Setting
Agency/
Country
22
13
21
11
20
26
17
28
18
33
18
-8
-15
-10
-22
-12
-27
FCC, IC
ETSI 5, ACMA
FCC, IC
ETSI 5, ACMA
FCC, IC
ETSI 5, ACMA
Notes:
1. The values in the above table have been determined through agency certification testing.
2. Maximum transmit power will vary by channel, data rate, and individual country regulations.
3. The following shall apply for antenna type, frequency range, application/usage and agency/country
compliance:
• Antenna gains above the maximum values shown shall not be used.
• Cable length/loss below the minimum values shown shall not be used.
• Maximum overall radio output power shown shall not be exceeded.
• Maximum EIRP values shown above shall not be exceeded.
4. Beam width, for sector and dish antenna, may range between 0 – 180degress.
5. France restricts outdoor use to 10mW (10dBm) EIRP in the frequency range of 2,454-2,483.5 MHz.
Installations in France must limit EIRP to 10dBm, for operating modes utilizing frequencies in the range
of 2,454 – 2,483.5MHz.
6. Industry Canada Compliance Statement: This device has been designed to operate with the antenna
types listed in this document, and having a maximum gain of 14dBi. Antenna types not included in this
list or having a gain greater than 14dBi are strictly prohibited for use with this device. The required
antenna impedance is 50 ohms.
Table 18 – EIRP Limits, 802.11b/g (2.4GHz) Radios
FCF:
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 27 of 36
Honeywell Proprietary
and Confidential
AT8
51121312
REVISIONS
18 Setting Power and Country Code: DSSS-FH Radio
Warning! The Multinode unit must be Professionally Installed in accordance with the
requirements specified in this document. Only the specified power settings, antenna types
and gains and cable lengths (attenuation) as outlined in this document are valid for Multinode
installations.
Set the radio power level using the Authentication Device application. Due to regulations, this
command is only available if professional installer options have explicitly been enabled on
your PDA. If you have not enabled professional installer options and would like to do so,
please contact Honeywell Design Engineering or Technical Assistance Center. A separate
application, AuthDev Power Settings, is required to enable the "Write TX Power Level" option.
Perform the following procedure to read and change the radio power level on your multinode
or wireless device:
•
Open the Authentication Device application on your Windows Mobile PDA.
•
From the main menu, choose the Advanced Options menu to open the Advanced
Options form.
•
From the Advanced Options form, choose "Read TX Power Level" from the command
drop down box.
•
Aim the Authentication Device at your node and press the Transmit Command button
to read the data from the node. The TX Power reading will be presented on your
screen.
•
If you have enabled professional installer options within the Authentication Device,
choose the "Write TX Power Level" from the command drop down box.
•
Choose a new power level. Aim the Authentication Device at your node and press the
Transmit Command button to write the data to the node.
FCF:
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 28 of 36
Honeywell Proprietary
and Confidential
AT8
51121312
REVISIONS
19 Setting Power & Country Code: 802.11 Access Point & Bridge Radio
Warning! The Multinode unit must be Professionally Installed in accordance with the
requirements specified in this document. Only the specified power settings, antenna types
and gains and cable lengths (attenuation) as outlined in this document are valid for Multinode
installations.
Programming the Country Code
A hidden page on the Multinode Configuration Tool has been designed for professional
installers to change country code and radio output power settings. A valid authorization code
has to be entered for the any information to be modified. This authorization code is hardcoded in the firmware and shall be kept as a SECRET at all times.
To access the hidden page, type the following URL in your browser:
https://192.168.254.128/cgi-bin/sgateway?PG=911
Change 192.168.254.128 to the IP address of your unit, and make sure you login as:
Login: CryptoOfficer, Password: CryptoFIPS
You should see something like this:
FCF:
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 29 of 36
Honeywell Proprietary
and Confidential
AT8
51121312
REVISIONS
The authorization code is: “Raptor2007!” without the quote (YOU MUST KEEP THIS AS A
SECRET)
Change the following options based on values you determined in Section 11:
Country Code
Adjustment to Max TX power of Access Point Radio (increase or decrease)
Adjustment to Max TX power of Bridge Radio (increase or decrease)
After applying the changes, you will be notified to reboot the unit for any changes to take
effect.
Note that the adjustment of radio Max TX power has limits. It will level off on both the low end
and high end. This feature is provided for professional installers to adjust the card output
power to match the specific selection of antenna and keep the total output power under the
regulatory threshold.
The setting here are saved in non-volatile memory inside the unit. Restoring the unit to
factory default settings does not change these values.
FCF:
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 30 of 36
Honeywell Proprietary
and Confidential
51121312
REVISIONS
AT8
19.1 Power Setting Reference Table, 802.11 Access Point & Bridge Radio:
Multinode Bridge and Access Point Radio Ports
WIRELESS MODE
802.11a
802.11a
802.11b/g mixed
802.11b/g mixed
CHANNEL
TX PWR MODE
Data Rate
120 (5.6GHz)
FIXED, 8
157 (5.785GHz)
FIXED, 8
7 (2.442GHz)
FIXED, 8
6 (2.437GHz)
FIXED, 8
MEASURED
OUTPUT POWER
(dBm)
25
25
24
24
22
18
14
MEASURED
OUTPUT POWER
(dBm)
27
27
27
26
24
21
16
12
MEASURED
OUTPUT POWER
(dBm)
26
26
26
25
21
15
10
MEASURED
OUTPUT POWER
(dBm)
26
26
26
26
25
21
15
10
Professional Installer
TX Power Setting
40
30
20
10
-10
-20
-30
-40
Table 19: 802.11 Radio Power Setting Reference
FCF:
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 31 of 36
Honeywell Proprietary
and Confidential
AT8
51121312
REVISIONS
20 RF Safety, Maximum Permissible Exposure (MPE) statement
To comply with FCC’s and Industry Canada’s RF exposure requirements, the following
antenna installation and device operating configurations must be satisfied.
Remote Point-to-Multi-Point antenna(s) for this unit must be fixed and mounted on
outdoor permanent structures with a separation distance between the antenna(s) of
greater than 20cm and a separation distance of at least 20cm from all persons.
Remote Fixed Point–to-Point antenna(s) for this unit must be fixed and mounted on
outdoor permanent structures with a separation distance between the antenna(s) of
greater than 20cm and a separation distance of at least 100cm from all persons.
Furthermore, when using integral antenna(s) the Multinode unit must not be co-located
with any other antenna or transmitter device and have a separation distance of at least
20cm from all persons.
FCF:
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 32 of 36
Honeywell Proprietary
and Confidential
51121312
REVISIONS
AT8
21 AGENCY COMPLIANCE
21.1 Radio and EMC Certifications
21.1.1 Federal Communication Commission (FCC)
Specification: FCC Part 15.247 Subpart B for unintentional radiators
Specification: FCC Part 15.247 Subpart C for intentional radiators
21.1.2 Industry Canada (IC)
Method: RSS-210, Issue 7
RSS-Gen, Issue 2
ICES-003, Issue 4
21.1.3 European Telecommunications Standards Institue (ETSI)
Emissions Specification and Method: EN 300 328 V1.7.1
Emissions Spec and Method: EN 301 893 V1.4.1
Immunity Specification: EN 301 489-17 V1.2.1
Immunity Method: EN 301 489-1 V1.6.1
Product Standard: IEC61326-1 (1st Edition, 2005, Industrial Locations)
21.1.4 Australian communications and media authority (ACMA)
Specification: AS NZS 4771-2000
FCF:
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 33 of 36
Honeywell Proprietary
and Confidential
AT8
51121312
REVISIONS
21.2 Product Safety Agency Certifications
21.2.1 Canadian Standards Association (CSA)
CSA electrical equipment requirements for use within Division 2 and Zone 2 hazardous
locations.
IEC61010-1 (2nd Edition, 2001-02), "Safety Requirements for Electrical Equipment for
Measurement, Control and Laboratory Use, part 1: General Requirements
Canadian Standards Association Standard C22.2 No. 213-M1987, "Non-Incendive Electrical
Equipment for Use in Class I, Division 2 Hazardous Locations"
Canadian Standards Association Standard E60079-0:02, “Electrical Apparatus for explosive
gas atmospheres – General Requirements”
Canadian Standards Association Standard E60079-15:02, “Electrical Apparatus for explosive
gas atmospheres – Type of Protection “n””
•
FCF:
Temperature code: T4 (135°C) based on the maximum specified ambient of 60°C.
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 34 of 36
Honeywell Proprietary
and Confidential
AT8
51121312
REVISIONS
21.2.2 Factory Mutual (FM)
FM electrical equipment requirements for use within Division 2 and Zone 2 hazardous
locations.
Factory Mutual Approval Standard Class No. 3600, "Electrical Equipment for Use in
Hazardous (Classified) Locations - General Requirements
Factory Mutual Approval Standard Class No. 3810, "Electrical and Electronic Test,
Measuring, and Process Control Equipment
Factory Mutual Approval Standard Class No. 3611, "Electrical Equipment for Use in Class I,
Division 2, Class II, Division 2 and Class III, Division 1 and 2 Hazardous (Classified)
Locations
ANSI/ISA 12.00.01-2002, “Electrical Apparatus for Use in Class I, Zones 0, 1 & 2 Hazardous
(Classified) Locations: General Requirements”
ANSI/ISA 12.12.02-2003, “Electrical Apparatus for explosive gas atmospheres – Type of
Protection “n””
•
FCF:
Temperature code: T4 (135°C) based on the maximum specified ambient of 60°C.
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 35 of 36
Honeywell Proprietary
and Confidential
AT8
51121312
REVISIONS
21.2.3 European ATEX Certification (ATEX)
The completely assembled Multinode will conform to European electrical equipment
requirements for use within Zone 2 Hazardous Locations.
IEC 60079-0:2004-01, “Electrical Apparatus for explosive gas atmospheres – General
Requirements
IEC 60079-15:2005-03, “Electrical Apparatus for explosive gas atmospheres – Type of
Protection “n”
•
Temperature code: T4 (135°C) based on the maximum specified ambient of 60°C.
21.3 European Union Certification (CE-mark)
•
Compliance with:
o R&TTE Directive 1999/5/EC
o EMC Directive 2004/108/EC
o LVD Directive 73/23/EEC
o ATEX Directive 94/9/EC
22 Reference Documents
Getting Started with Honeywell OneWireless
Honeywell OneWireless Planning Guide
Honeywell OneWireless Multinode User’s Guide
Radio Antenna: A Primer White Paper
Honeywell OneWireless System Administration Guide
Honeywell OneWireless Field Network Dictionary
OneWireless Builder Parameter Reference
OneWireless Builder User’s Guide
FCF:
OneWireless Multinode Agency Compliance
Professional Installation Guide
FMF:
Made by: David Shipley
Issue:
AT8 29-JUL-2008
Approval
Prints to
Honeywell
IACD/Ft.W
51121312
SIZE Sh. No.: 36 of 36

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2008:09:04 12:48:50-07:00
Modify Date                     : 2008:09:04 12:48:50-07:00
Page Count                      : 36
Creation Date                   : 2008:09:04 19:48:50Z
Mod Date                        : 2008:09:04 19:48:50Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Metadata Date                   : 2008:09:04 19:48:50Z
EXIF Metadata provided by EXIF.tools
FCC ID Filing: S57-51306343

Navigation menu