Honeywell BT010M 10 Meter BT Module User Manual Voyager 1200g 1202g User s Guide

Honeywell International Inc. 10 Meter BT Module Voyager 1200g 1202g User s Guide

Contents

User Manual

Download: Honeywell BT010M 10 Meter BT Module User Manual Voyager 1200g 1202g User        s Guide
Mirror Download [FCC.gov]Honeywell BT010M 10 Meter BT Module User Manual Voyager 1200g 1202g User        s Guide
Document ID1663573
Application IDajqntTx6DIQZjT8roB3cIw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize245.65kB (3070675 bits)
Date Submitted2012-03-27 00:00:00
Date Available2012-03-27 00:00:00
Creation Date2011-09-15 10:16:43
Producing SoftwareAcrobat Distiller 9.4.5 (Windows)
Document Lastmod2011-09-15 11:22:17
Document TitleVoyager 1200g/1202g User’s Guide
Document CreatorFrameMaker 9.0
Document Author: Honeywell Scanning & Mobility

Voyager™ 1200g/1202g
Single-Line Laser Scanner
User’s Guide
™
ft
15
Disclaimer
Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice,
and the reader should in all cases consult HII to determine whether any such
changes have been made. The information in this publication does not represent a commitment on the part of HII.
HII shall not be liable for technical or editorial errors or omissions contained
herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material.
This document contains proprietary information that is protected by copyright.
All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of
HII.
© 2010-2011 Honeywell International Inc. All rights reserved.
Other product names or marks mentioned in this document may be trademarks
or registered trademarks of other companies and are the property of their
respective owners.
Web Address: www.honeywellaidc.com
Microsoft® Windows® and the Windows logo are trademarks or registered
trademarks of Microsoft Corporation.
The Bluetooth® word mark and logos are owned by Bluetooth SIG, Inc.
Other product names or marks mentioned in this document may be trademarks
or registered trademarks of other companies and are the property of their
respective owners.
Product Agency Compliance - Voyager 1200g
USA
FCC Part 15 Subpart B Class B
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a
Class B digital device pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio or television technician for
help.
If necessary, the user should consult the dealer or an experienced radio/
television technician for additional suggestions. The user may find the following booklet helpful: “Something About Interference.” This is available at
FCC local regional offices. Honeywell is not responsible for any radio or
television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment
other than those specified by Honeywell. The correction is the responsibility of the user.
Use only shielded data cables with this system. This unit has been tested
with cables less than 3 meters. Cables greater than 3 meters may not meet
class B performance.
Caution: Any changes or modifications made to this equipment not
expressly approved by Honeywell may void the FCC authorization to operate this equipment.
UL Statement
UL listed: UL60950-1, 2nd Edition.
Canada
Industry Canada ICES-003
This Class B digital apparatus complies with Canadian ICES-003. Operation is subject to the following conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operation.
Conformité à la règlementation canadienne
Cet appareil numérique de la Classe A est conforme à la norme NMB-003
du Canada. Son fonctionnement est assujetti aux conditions suivantes :
1. Cet appareil ne doit pas causer de brouillage préjudiciable.
2. Cet appareil doit pouvoir accepter tout brouillage reçu, y compris le
brouillage pouvant causer un fonctionnement indésirable.
C-UL Statement
C-UL listed: CSA C22.2 No.60950-1-07, Second Edition.
Europe
The CE marking indicates compliance to 2004/108/EC EMC Directive
with Standards EN55022 CLASS B, EN55024, EN61000-3-2,
EN61000-3-3. In addition, complies to 2006/95/EC Low Voltage Directive, when shipped with recommended power supply.
For further information please contact:
Honeywell Imaging & Mobility Europe BV
Nijverheidsweg 9-13
5627 BT Eindhoven
The Netherlands
Honeywell International Inc. shall not be liable for use of our product with
equipment (i.e., power supplies, personal computers, etc.) that is not CE
marked and does not comply with the Low Voltage Directive.
Waste Electrical and Electronic Equipment
Information
Honeywell complies with Directive 2002/96/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 27 January 2003 on waste electrical
and electronic equipment (WEEE).
This product has required the extraction and use of natural resources for its
production. It may contain hazardous substances that could impact health
and the environment, if not properly disposed.
In order to avoid the dissemination of those substances in our environment
and to diminish the pressure on the natural resources, we encourage you to
use the appropriate take-back systems for product disposal. Those systems will reuse or recycle most of the materials of the product you are disposing in a sound way.
The crossed out wheeled bin symbol informs you that the product
should not be disposed of along with municipal waste and invites you to
use the appropriate separate take-back systems for product disposal.
If you need more information on the collection, reuse, and recycling systems, please contact your local or regional waste administration.
You may also contact your supplier for more information on the environmental performances of this product.
Germany
GS Statement
GS marked to EN60950-1, Second Edition.
Australia/NZ
C-Tick Statement
Conforms to AS/NZS 3548 EMC requirement
Mexico
Conforms to NOM-019.
Russia
Gost-R certificate
South Korea
This product meets Korean agency approval.
Taiwan
If the following label is attached to your product, the product meets Taiwan
agency approval:
BSMI Standard: CNS13438, CNS 14336
依據標準 : CNS13438, CNS14336
International
LED Safety Statement
LEDs have been tested and classified as “EXEMPT RISK GROUP” to the
standard: IEC 62471:2006.
CB Scheme
Certified to CB Scheme IEC60950-1, Second Edition.
Laser Safety Statement
LASER LIGHT: DO NOT STARE INTO
BEAM. CLASS 2 LASER PRODUCT.
LASERSTRAHLUNG: NICHT IN DEN
STRAHL BLICKEN. LASER KLASSE 2.
LUMIERE LASER: NE PAS REGARDER
DANS LE FAISCEAU. APPAREIL A LASER.
DE CLASSE 2 630-650nm, 1mW.
This device has been tested in accordance with and complies with
IEC60825-1 ed2.0 and 21 CFR 1040.10 and 1040.11, except for deviations
pursuant to Laser Notice No. 50, dated June 24, 2007.
LASER LIGHT, DO NOT STARE INTO BEAM, CLASS 2 LASER PRODUCT, 1.0 mW MAX OUTPUT: 630-650nM.
Scanner Laser Beam
Wavelength 645 - 660 nm
Divergence < 1.5 mrad. per IEC 60825-1 worst case
Max power output < 1mw
Embedded Laser
Wavelength 645- 660 nm
Divergence < 1.5 mrad, per IEC 60825-1 worst case
Max power output < 10 mw
Caution - use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous radiation exposure.
Patents
For patent information, please refer to www.honeywellaidc.com/patents.
Solids and Water Protection
The Voyager 1200g has a rating of IP42, immunity of foreign particles and dripping water.
Product Agency Compliance - Voyager 1202g and
CCB00-010BT Charge Base
USA
FCC Part 15 Subpart C
This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operation.
Caution:
Any changes or modifications made to this equipment not
expressly approved by Honeywell may void the FCC
authorization to operate this equipment.
Use only shielded data cables with this system. This unit has been tested
with cables less than 3 meters. Cables greater than 3 meters may not meet
class B performance.
UL Statement
UL listed: UL60950-1, Second Edition.
Canada
Industry Canada
This device complies with Canadian RSS-210. Operation is subject to the
following conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that
may cause undesired operation.
Conformité à la règlementation canadienne
Cet appareil ISM est conforme à la norme CNR-210 du Canada. Son fonctionnement est assujetti aux conditions suivantes :
1. Cet appareil ne doit pas causer de brouillage préjudiciable.
2. Cet appareil doit pouvoir accepter tout brouillage reçu, y compris le
brouillage pouvant causer un fonctionnement indésirable.
C-UL Statement
C-UL listed: CSA C22.2 No.60950-1-07, Second Edition.
Europe
The CE marking on the product indicates that this device is in conformity with all essential requirements of the 1999/5/EC R&TTE Directive.
In addition, complies to 2006/95/EC Low Voltage Directive, when
shipped with recommended power supply. For further information, contact:
Honeywell Imaging & Mobility Europe BV
International Inc.
Nijverheidsweg 9-13
5627 BT Eindhoven
The Netherlands
Honeywell shall not be liable for use of our product with equipment (i.e.,
power supplies, personal computers, etc.) that is not CE marked and does
not comply with the Low Voltage Directive. This equipment is intended for
use throughout the European Community and has been assessed to the
following standards:
EN 300 328
EN 301 489-1
EN 301 489-17
EN60950-1
Waste Electrical and Electronic Equipment
Information
Honeywell complies with Directive 2002/96/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL on waste electrical and electronic
equipment (WEEE).
This product has required the extraction and use of natural resources for its
production. It may contain hazardous substances that could impact health
and the environment, if not properly disposed.
In order to avoid the dissemination of those substances in our environment
and to diminish the pressure on the natural resources, we encourage you to
use the appropriate take-back systems for product disposal. Those systems will reuse or recycle most of the materials of the product you are disposing in a sound way.
The crossed out wheeled bin symbol informs you that the product
should not be disposed of along with municipal waste and invites you to
use the appropriate separate take-back systems for product disposal.
If you need more information on the collection, reuse, and recycling systems, contact your local or regional waste administration.
You may also contact your supplier for more information on the environmental performances of this product.
Australia/NZ
C-Tick Statement
Conforms to AS/NZS 3548 EMC requirements.
China
SRRC Radio Certificate.
CCC safety (CCB00-010BT base only)
Japan
Complies with Technical Regulations Conformity Certification of
Specified Radio equipment.
Korea
This product meets Korean agency approval.
Russia
Gost-R certificate
Taiwan
If the following label is attached to your product, the product meets Taiwan
agency approval:
BSMI Standard: CNS13438, CNS14336 (Xenon 1902 only)
依據標準 : CNS13438, CNS14336
NCC standard: Low power frequency electric machineries technical
standard: LP0002
International
LED Safety Statement
LEDs have been tested and classified as “EXEMPT RISK GROUP” to the
standard: IEC 62471:2006.
Radio Technology
Class II
CB Scheme
Certified to CB Scheme IEC 60950-1, Second Edition.
Laser Safety Statement
LASER LIGHT: DO NOT STARE INTO
BEAM. CLASS 2 LASER PRODUCT.
LASERSTRAHLUNG: NICHT IN DEN
STRAHL BLICKEN. LASER KLASSE 2.
LUMIERE LASER: NE PAS REGARDER
DANS LE FAISCEAU. APPAREIL A LASER.
DE CLASSE 2 630-650nm, 1mW.
This device has been tested in accordance with and complies with
IEC60825-1 ed2.0 and 21 CFR 1040.10 and 1040.11, except for deviations
pursuant to Laser Notice No. 50, dated June 24, 2007.
LASER LIGHT, DO NOT STARE INTO BEAM, CLASS 2 LASER PRODUCT, 1.0 mW MAX OUTPUT: 630-650nM.
Scanner Laser Beam
Wavelength 645 - 660 nm
Divergence < 1.5 mrad. per IEC 60825-1 worst case
Max power output < 1mw
Embedded Laser
Wavelength 645- 660 nm
Divergence < 1.5 mrad, per IEC 60825-1 worst case
Max power output < 10 mw
Caution - use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous radiation exposure.
Patents
For patent information, please refer to www.honeywellaidc.com/patents.
Solids and Water Protection
The Voyager 1202g has a rating of IP42, immunity of foreign particles and dripping water.
Voyager 1200g Safety Label Locations
Laser Output
Internal Laser Cautions
Compliance Markings
information, Part Number,
and Serial Number
information
Compliance Markings
information
Voyager 1202g Safety Label Locations
Laser Output
Internal Laser Cautions
Laser Safety Information
Compliance Markings
information, Part Number,
and Serial Number
information
Compliance Markings
information
CCB00-010BT Safety Label Locations
Item Number,
Serial
Number, and
Compliance
Markings
information
Compliance
Markings
information
Table of Contents
Chapter 1 - Getting Started
About This Manual ...................................................... 1-1
Unpacking Your Device............................................... 1-1
Connecting the Device ................................................ 1-2
Connecting with USB ............................................ 1-2
Connecting with Keyboard Wedge ........................ 1-3
Connecting with RS232 Serial Port ....................... 1-6
Connecting with RS485......................................... 1-7
Reading Techniques ................................................... 1-8
Menu Bar Code Security Settings ............................... 1-8
Setting Custom Defaults ............................................. 1-9
Resetting the Custom Defaults ................................. 1-10
Resetting the Factory Defaults .................................. 1-10
Chapter 2 - Programming the Interface
Introduction ................................................................. 2-1
Programming the Interface - Plug and Play ................ 2-1
Keyboard Wedge................................................... 2-1
IBM PS2 Keyboard................................................ 2-1
RS232 Serial Port.................................................. 2-1
RS485 ................................................................... 2-2
OPOS Mode .......................................................... 2-3
USB IBM SurePos................................................. 2-4
IBM Secondary Interface....................................... 2-4
USB PC or Macintosh Keyboard ........................... 2-5
USB HID................................................................ 2-5
HID Fallback Mode................................................ 2-5
USB Serial Commands ............................................... 2-6
USB Serial Emulation............................................ 2-6
CTS/RTS Emulation .............................................. 2-6
ACK/NAK Mode..................................................... 2-7
Communication Timeout ....................................... 2-7
NAK Retries........................................................... 2-8
Support BEL/CAN in ACK/NAK............................. 2-8
Verifone® Ruby Terminal Default Settings ..................2-9
Gilbarco® Terminal Default Settings ............................2-9
Honeywell Bioptic Aux Port Configuration .................2-10
Datalogic™ Magellan© Bioptic
Aux Port Configuration ............................................2-10
NCR Bioptic Aux Port Configuration ..........................2-10
Wincor Nixdorf Terminal Default Settings..................2-11
Wincor Nixdorf Beetle™ Terminal Default Settings ...2-12
Keyboard Country Layout ..........................................2-13
Keyboard Wedge Modifiers .......................................2-14
ALT Mode ............................................................ 2-14
Keyboard Style .................................................... 2-15
Keyboard Conversion .......................................... 2-16
Keyboard Modifiers .............................................. 2-16
Inter-Scan Code Delay ........................................ 2-17
 Break Character ......................................... 2-18
Keyboard Wedge Defaults ................................... 2-18
RS232 Modifiers ........................................................2-19
RS232 Baud Rate................................................ 2-19
RS232 Word Length: Data Bits, Stop Bits,
and Parity ....................................................... 2-20
RS232 Handshaking ............................................ 2-21
RS232 Timeout .................................................... 2-22
XON/XOFF .......................................................... 2-22
ACK/NAK ............................................................. 2-23
Communication Timeout ...................................... 2-23
NAK Retries ......................................................... 2-24
Support BEL/CAN in ACK/NAK ........................... 2-25
RS232 Defaults.................................................... 2-25
NCR Modifiers ...........................................................2-25
NCR ACK/NAK .................................................... 2-25
Block Check Character ........................................ 2-26
NCR Prefix ........................................................... 2-26
NCR Suffix ........................................................... 2-26
NCR Prefix/Suffix ................................................. 2-27
NCR NOF (Not-on-File) Error .............................. 2-27
Scanner to Bioptic Communication............................2-27
ii
Scanner-Bioptic Packet Mode ............................. 2-28
ACK/NAK............................................................. 2-28
Communication Timeout ..................................... 2-28
Chapter 3 - Cordless System Operation
How the Cordless Charge Base Works....................... 3-1
Linking the Scanner to a Charge Base ....................... 3-1
Communication Between the Cordless System
and the Host.............................................................. 3-2
RF (Radio Frequency) Module Operation ................... 3-2
System Conditions ...................................................... 3-3
Linking Process ..................................................... 3-3
Scanner Is Out of Range....................................... 3-3
Scanner Is Moved Back Into Range...................... 3-3
Out of Range and Back into Range
with Batch Mode On......................................... 3-3
Page Button ................................................................ 3-3
About the Battery ........................................................ 3-4
Voyager 1202 Battery Removal .................................. 3-4
Charging Information............................................. 3-4
Battery Recommendations .................................... 3-5
Proper Disposal of the Battery .............................. 3-6
Flash Updates ............................................................. 3-6
Beeper and LED Sequences and Meaning ................. 3-6
Scanner LED Sequences and Meaning ................ 3-6
Base LED Sequences and Meaning ..................... 3-7
Base Power Communication Indicator .................. 3-7
Reset Scanner ............................................................ 3-8
Scanning While in Base Cradle................................... 3-8
Paging ......................................................................... 3-8
Paging Mode ......................................................... 3-8
Paging Pitch ......................................................... 3-9
Error Indicators............................................................ 3-9
Scanner Address......................................................... 3-9
Base Address ............................................................ 3-10
Scanner Modes ......................................................... 3-10
iii
Charge Only Mode............................................... 3-10
Linked Modes ...................................................... 3-11
Unlinking the Scanner................................................3-11
Override Locked Scanner ..........................................3-12
Out-of-Range Alarm...................................................3-12
Alarm Sound Type ............................................... 3-12
Alarm Duration ..................................................... 3-12
Scanner Power Time-Out Timer ................................3-13
Batch Mode................................................................3-13
Batch Mode Beep ................................................ 3-14
Batch Mode Quantity ........................................... 3-14
Delete Last Code ................................................. 3-17
Record Counter ................................................... 3-17
Total Records ...................................................... 3-17
Batch Mode Output Order.................................... 3-18
Clear All Codes After Transmission ..................... 3-18
Clear All Codes .................................................... 3-18
Transmit Records Automatically .......................... 3-19
Transmit Records to Host .................................... 3-19
Batch Mode Transmit Delay ................................ 3-20
Scanner Name...........................................................3-20
Using the Scanner with Bluetooth Devices................3-22
Changing the Scanner’s Bluetooth PIN Code...... 3-22
Minimizing Bluetooth/ISM Band Network Activity ......3-22
Auto Reconnect Mode ......................................... 3-23
Maximum Link Attempts ...................................... 3-24
Relink Time-Out ................................................... 3-24
Bluetooth/ISM Network Activity Examples ........... 3-24
Reset Scanner and Base...........................................3-25
Chapter 4 - Input/Output Settings
Power Up Beeper ........................................................4-1
Beep on BEL Character...............................................4-1
Good Read and Error Indicators..................................4-2
Beeper – Good Read ............................................. 4-2
Beeper Volume – Good Read................................ 4-2
iv
Beeper Pitch – Good Read ................................... 4-3
Beeper - Transmit Order ....................................... 4-3
Beeper Pitch – Error.............................................. 4-3
Beeper Duration – Good Read.............................. 4-4
Number of Beeps – Good Read ............................ 4-4
Number of Beeps – Error ...................................... 4-4
LED Indicators............................................................. 4-6
LED Settings ......................................................... 4-6
LED Brightness ..................................................... 4-8
In-Stand and Out-Of-Stand Settings ........................... 4-8
In-Stand and Out-of-Stand Defaults ...................... 4-9
Presentation Modes .............................................. 4-9
Manual Activation Mode ...................................... 4-10
End Manual Activation After Good Read............. 4-10
Manual Activation Laser Timeout
- Button Settings ............................................ 4-11
CodeGate® .......................................................... 4-12
Object Detection Mode........................................ 4-12
End Object Detection After Good Read .............. 4-13
Object Detection Laser Timeout.......................... 4-13
Object Detection Distance................................... 4-14
Character Activation Mode ........................................ 4-14
Activation Character ............................................ 4-14
End Character Activation After Good Read......... 4-15
Character Activation Laser Timeout .................... 4-15
Character Deactivation Mode.................................... 4-16
Deactivation Character........................................ 4-16
Reread Delay ............................................................ 4-17
User-Specified Reread Delay.................................... 4-17
Output Sequence Overview ...................................... 4-17
Require Output Sequence................................... 4-17
Output Sequence Editor ...................................... 4-18
To Add an Output Sequence............................... 4-18
Other Programming Selections ........................... 4-18
Output Sequence Editor ...................................... 4-20
Sequence Timeout .............................................. 4-20
Sequence Match Beeper..................................... 4-21
Partial Sequence ................................................. 4-21
Require Output Sequence ................................... 4-21
No Read.....................................................................4-22
Chapter 5 - Data Editing
Prefix/Suffix Overview..................................................5-1
To Add a Prefix or Suffix: ....................................... 5-1
To Clear One or All Prefixes or Suffixes ................ 5-2
To Add a Carriage Return Suffix
to All Symbologies............................................ 5-3
Prefix Selections ..........................................................5-3
Suffix Selections ..........................................................5-4
Transmit Alternate Extended ASCII Characters ..........5-4
Function Code Transmit ..............................................5-6
Communication Check Character................................5-6
Intercharacter, Interfunction,
and Intermessage Delays..........................................5-7
Intercharacter Delay .............................................. 5-7
User Specified Intercharacter Delay ...................... 5-7
Interfunction Delay ................................................. 5-8
Intermessage Delay ............................................... 5-9
Chapter 6 - Data Formatting
Data Format Editor Introduction...................................6-1
To Add a Data Format .................................................6-1
Other Programming Selections.............................. 6-3
Terminal ID Table ........................................................6-4
Data Format Editor Commands ...................................6-4
Move Commands................................................... 6-5
Search Commands ................................................ 6-6
Miscellaneous Commands..................................... 6-7
Data Formatter.............................................................6-8
Data Format Non-Match Error Tone ...................... 6-9
Primary/Alternate Data Formats ................................6-10
Single Scan Data Format Change ....................... 6-10
vi
Chapter 7 - Symbologies
All Symbologies........................................................... 7-1
Message Length Description....................................... 7-2
Codabar ...................................................................... 7-3
Codabar Concatenation ........................................ 7-4
Code 39....................................................................... 7-7
Code 32 Pharmaceutical (PARAF)........................ 7-9
Full ASCII .............................................................. 7-9
Interleaved 2 of 5 ...................................................... 7-11
NEC 2 of 5................................................................. 7-13
Code 93..................................................................... 7-15
Straight 2 of 5 Industrial (three-bar start/stop) .......... 7-16
Straight 2 of 5 IATA (two-bar start/stop).................... 7-18
Matrix 2 of 5 .............................................................. 7-19
Code 11..................................................................... 7-21
Code 128................................................................... 7-24
ISBT 128 ................................................................... 7-25
GS1-128 .................................................................... 7-31
Telepen ..................................................................... 7-33
UPC-A ....................................................................... 7-35
UPC-A/EAN-13 with Extended Coupon Code........... 7-38
UPC-A Number System 4 Addenda Required .... 7-38
UPC-A Number System 5 Addenda Required .... 7-39
UPC-E0 ..................................................................... 7-41
EAN/JAN-13 .............................................................. 7-45
EAN-13 Beginning with 2 Addenda Required ..... 7-46
EAN-13 Beginning with 290
Addenda Required ......................................... 7-47
EAN-13 Beginning with 378/379
Addenda Required ......................................... 7-47
EAN-13 Beginning with 414/419
Addenda Required ......................................... 7-48
EAN-13 Beginning with 434/439
Addenda Required ......................................... 7-49
EAN-13 Beginning with 977
Addenda Required ......................................... 7-50
vii
EAN-13 Beginning with 978
Addenda Required ......................................... 7-50
EAN-13 Beginning with 979
Addenda Required ......................................... 7-51
ISBN Translate .................................................... 7-53
ISSN Translate .................................................... 7-54
EAN/JAN-8 ................................................................7-55
MSI ............................................................................7-58
Plessey Code.............................................................7-60
GS1 DataBar Omnidirectional ...................................7-62
GS1 DataBar Limited.................................................7-63
GS1 DataBar Expanded ............................................7-64
Trioptic Code .............................................................7-65
GS1 Emulation...........................................................7-65
Postal Codes .............................................................7-66
China Post (Hong Kong 2 of 5) ............................ 7-66
Chapter 8 - Interface Keys
Keyboard Function Relationships ................................8-1
Supported Interface Keys ............................................8-2
Chapter 9 - Utilities
To Add a Test Code I.D. Prefix to All Symbologies .....9-1
Show Software Revision..............................................9-1
Show Data Format.......................................................9-1
Test Menu....................................................................9-2
EZConfig-Scanning Introduction..................................9-2
Installing EZConfig-Scanning from the Web .......... 9-3
Chapter 10 - Serial Programming Commands
Conventions...............................................................10-1
Menu Command Syntax ............................................10-1
Query Commands......................................................10-2
Responses ........................................................... 10-3
Serial Trigger Commands..........................................10-4
viii
Read Time-Out.................................................... 10-4
Resetting the Standard Product Defaults .................. 10-4
Menu Commands ...................................................... 10-6
Chapter 11 - Product Specifications
Voyager 1200g Scanner Product Specifications ....... 11-1
Voyager 1202g Scanner Product Specifications ....... 11-3
CCB00-010BT Charge Base Product Specifications 11-4
CCB00-010BT Charge Base Mounting ..................... 11-6
Standard Cable Pinouts ............................................ 11-7
Keyboard Wedge................................................. 11-7
Serial Output ...................................................... 11-8
RS485 Output ..................................................... 11-9
USB ................................................................... 11-10
Chapter 12 - Maintenance
Repairs ...................................................................... 12-1
Maintenance.............................................................. 12-1
Cleaning the Device ............................................ 12-1
Inspecting Cords and Connectors ....................... 12-1
Replacing Cables in Corded Scanners ..................... 12-1
Replacing an Interface Cable
in a Corded Scanner ...................................... 12-2
Replacing Cables in Cordless Systems .................... 12-2
Replacing an Interface Cable in a Base .............. 12-2
Troubleshooting a Voyager Scanner......................... 12-3
Troubleshooting a Cordless System ......................... 12-4
Troubleshooting a Base ...................................... 12-4
Troubleshooting a Cordless Scanner .................. 12-5
ix
Chapter 13 - Customer Support
Appendix A - Reference Charts
Symbology Chart ........................................................ A-1
ASCII Conversion Chart (Code Page 1252) ............... A-4
Code Page Mapping of Printed Barcodes .................. A-6
1
Getting Started
About This Manual
This User’s Guide provides installation and programming instructions for the
Voyager 1200g linear scanner. Product specifications, dimensions, warranty,
and customer support information are also included.
Honeywell bar code scanners are factory programmed for the most common
terminal and communications settings. If you need to change these settings,
programming is accomplished by scanning the bar codes in this guide.
An asterisk (*) next to an option indicates the default setting.
Unpacking Your Device
After you open the shipping carton containing the product, take the following
steps:
• Check for damage during shipment. Report damage immediately to the
carrier who delivered the carton.
• Make sure the items in the carton match your order.
• Save the shipping container for later storage or shipping.
1-1
Connecting the Device
Connecting with USB
A scanner or a cordless base can be connected to the USB port of a computer.
1.
Connect the appropriate interface cable to the scanner first, then to
the computer.
Cordless Base USB
Connection:
2.
1-2
Make sure the cables are secured in the wireways in the bottom of the
cordless base and that the base sits flat on a horizontal surface.
3.
The scanner beeps.
4.
Verify the scanner or cordless base operation by scanning a bar code
from the Sample Symbols in the back of this manual.
The unit defaults to a USB PC Keyboard. Refer to page 2-5 for other USB
terminal settings.
For additional USB programming and technical information, refer to “USB
Application Note,” available at www.honeywellaidc.com.
Connecting with Keyboard Wedge
A scanner or cordless base can be connected between the keyboard and
PC as a “keyboard wedge,” where the scanner provides data output that is
similar to keyboard entries. The following is an example of a keyboard
wedge connection:
1.
Turn off power and disconnect the keyboard cable from the back of the
terminal/computer.
1-3
2.
Connect the appropriate interface cable to the scanner and to the
terminal/computer.
only if
power
supply is
included
Cordless Base
Keyboard Wedge
Connection:
3.
Make sure the cables are secured in the wireways in the bottom of the
cordless base and that the base sits flat on a horizontal surface.
4.
Turn the terminal/computer power back on. The scanner beeps.
5.
Verify the scanner or cordless base operation by scanning a bar code
from the Sample Symbols in the back of this manual. The scanner
beeps once.
1-4
The unit defaults to an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard. A carriage return (CR) suffix is added to bar
code data.
1-5
Connecting with RS232 Serial Port
1.
Turn off power to the terminal/computer.
2.
Connect the appropriate interface cable to the scanner.
Note: For the scanner or cordless base to work properly, you must have the
correct cable for your type of terminal/computer.
only if
power
supply is
included
Cordless Base
RS232 Serial Port
Connection:
1-6
3.
Make sure the cables are secured in the wireways in the bottom of the
cordless base and that the base sits flat on a horizontal surface.
4.
Plug the serial connector into the serial port on your computer.
Tighten the two screws to secure the connector to the port.
5.
Once the scanner or cordless base has been fully connected, power
up the computer.
This interface programs 9600 baud, 8 data bits, no parity, and 1 stop bit.
Connecting with RS485
A scanner or cordless base can be connected for an IBM POS terminal
interface.
1.
Connect the appropriate interface cable to the device, then to the computer.
Cordless Base
RS485
Connection:
1-7
2.
Make sure the cables are secured in the wireways in the bottom of the
cordless base and that the base sits flat on a horizontal surface.
3.
Turn the terminal/computer power back on. The scanner beeps.
4.
Verify the scanner or cordless base operation by scanning a bar code
from the Sample Symbols in the back of this manual. The scanner
beeps once.
For further RS485 settings, refer to RS485, page 2-2.
Reading Techniques
The scanner has a view finder that projects a bright red aiming beam that corresponds to the scanner’s horizontal field of view. The aiming beam should be
centered horizontally over the bar code and must highlight all the vertical bars
of the bar code. It will not read if the aiming beam is in any other direction.
Good Read
Bad Read
The aiming beam is smaller when the scanner is closer to the code and larger
when it is farther from the code. Symbologies with smaller bars or elements
(mil size) should be read closer to the unit. Symbologies with larger bars or elements (mil size) should be read farther from the unit. To read single or multiple
symbols (on a page or on an object), hold the scanner at an appropriate distance from the target, press the button, and center the aiming beam on the symbol. If the code being scanned is highly reflective (e.g., laminated), it may be
necessary to tilt the code up 15° to 18° to prevent unwanted reflection.
Menu Bar Code Security Settings
Honeywell scanners are programmed by scanning menu bar codes or by sending serial commands to the scanner. If you want to restrict the ability to scan
menu codes, you can use the Menu Bar Code Security settings. Please contact
the nearest technical support office (see Limited Warranty on page 13-3) for further information.
1-8
Setting Custom Defaults
You have the ability to create a set of menu commands as your own, custom
defaults. To do so, scan the Set Custom Defaults bar code below before each
menu command or sequence you want saved. If your command requires scanning numeric codes from the back cover, then a Save code, that entire
sequence will be saved to your custom defaults. Scan the Set Custom
Defaults code again before the next command you want saved to your custom
defaults.
When you have entered all the commands you want to save for your custom
defaults, scan the Save Custom Defaults bar code.
Set Custom Defaults
Save Custom Defaults
Note: If using a cordless system, scanning the Save Defaults bar code also
causes both the scanner and the base to perform a reset and become
unlinked. The scanner must be placed in its base to re-establish the link
before any setup codes are entered. See Cordless System
Operation beginning on page 3-1 for additional information.
You may have a series of custom settings and want to correct a single setting.
To do so, just scan the new setting to overwrite the old one. For example, if you
had previously saved the setting for Beeper Volume at Low to your custom
defaults, and decide you want the beeper volume set to High, just scan the Set
Custom Defaults bar code, then scan the Beeper Volume High menu code,
and then Save Custom Defaults. The rest of the custom defaults will remain,
but the beeper volume setting will be updated.
1-9
Resetting the Custom Defaults
If you want the custom default settings restored to your scanner, scan the Activate Custom Defaults bar code below. This resets the scanner to the custom
default settings. If there are no custom defaults, it will reset the scanner to the
factory default settings. Any settings that have not been specified through the
custom defaults will be defaulted to the factory default settings.
Activate Custom Defaults
Note: If using a cordless system, scanning this bar code also causes both the
scanner and the base to perform a reset and become unlinked. The
scanner must be placed in its base to re-establish the link before any
setup codes are entered. See Cordless System Operation beginning on
page 3-1 for additional information.
Resetting the Factory Defaults
This selection erases all your settings and resets the scanner to the
original factory defaults.
If you aren’t sure what programming options are in your scanner, or you’ve
changed some options and want to restore the scanner to factory default settings, first scan the Remove Custom Defaults bar code, then scan Activate
Defaults. This resets the scanner to the factory default settings.
Remove Custom Defaults
Activate Defaults
Note: If using a cordless system, scanning the Activate Defaults bar code also
causes both the scanner and the base to perform a reset and become
unlinked. The scanner must be placed in its base to re-establish the link
before any setup codes are entered. See Cordless System
Operation beginning on page 3-1 for additional information.
The Serial Programming Commands, beginning on page 10-1 list the factory
default settings for each of the commands (indicated by an asterisk (*) on the
programming pages).
1 - 10
2
Programming the Interface
Introduction
This chapter describes how to program your system for the desired interface.
Programming the Interface - Plug and Play
Plug and Play bar codes provide instant scanner set up for commonly used
interfaces.
Note: After you scan one of the codes, power cycle the host terminal to have
the interface in effect.
Keyboard Wedge
If you want your system programmed for an IBM PC AT and compatibles
keyboard wedge interface with a USA keyboard, scan the bar code below.
Keyboard wedge is the default interface.
Note: The following bar code also programs a carriage return (CR) suffix.
IBM PC AT and Compatibles with CR Suffix
IBM PS2 Keyboard
The following bar code programs you scanner for an IBM PS2 keyboard
wedge interface with a USA keyboard.
Note: The following bar code also programs a carriage return (CR) suffix.
IBM PS2 with CR Suffix
RS232 Serial Port
The RS232 Interface bar code is used when connecting to the serial port
of a PC or terminal. The following RS232 Interface bar code also programs a carriage return (CR) and a line feed (LF) suffix, baud rate, and
data format as indicated below.
Option
Setting
Baud Rate
Data Format
9600 bps
8 data bits, no parity bit, 1 stop bit
2-1
RS232 Interface
RS485
Scan one of the following “Plug and Play” codes to program the scanner for
an IBM POS terminal interface.
Note: After scanning one of these codes, you must power cycle the cash
register.
IBM Port 5B Interface
IBM Port 9B
HHBCR-1 Interface
IBM Port 17 Interface
IBM Port 9B
HHBCR-2 Interface
Each bar code above also programs the following suffixes for each symbology:
Symbology
Suffix
Symbology
Suffix
EAN 8
EAN 13
UPC A
UPC E
0C
16
0D
0A
Code 39
Interleaved 2 of 5
Code 128 *
Code 128 **
00
00
00
00
0A
0D
0A
18
0B
0B
0B
0B
* Suffixes programmed for Code 128 with IBM 4683 Port 5B, IBM 4683 Port 9B
HHBCR-1, and IBM 4683 Port 17 Interfaces
**Suffixes programmed for Code 128 with IBM 4683 Port 9 HHBCR-2 Interface
2-2
OPOS Mode
The following bar code configures your scanner for OPOS (OLE for Retail
Point of Sale) by modifying the following OPOS-related settings:
Option
Setting
Interface
Baud Rate
RS232
Handshaking
RS232
38400
Flow Control, No Timeout
XON/XOFF Off
ACK/NAK Off
8 Data, 1 Stop, Parity None
Data Bits, Stop
Bits, and Parity
Prefix/Suffix
Intercharacter
Delay
Symbologies
Clear All Prefixes and Suffixes
Add Code ID and AIM ID Prefix
Add CR Suffix
Off
Enable UPC-A with check digit and number system
Enable UPC-E0 with check digit
Enable EAN/JAN-8 with check digit
Enable EAN/JAN-13 with check digit
Enable Code 128
Enable Code 39
Enable OPOS with automatic disable off
OPOS Mode
2-3
USB IBM SurePos
Scan one of the following “Plug and Play” codes to program the scanner for
an IBM SurePos (USB handheld scanner) or IBM SurePos (USB tabletop
scanner) interface.
Note: After scanning one of these codes, you must power cycle the cash
register.
USB IBM SurePos
(USB Handheld Scanner)
Interface
USB IBM SurePos
(USB Tabletop Scanner)
Interface
Each bar code above also programs the following suffixes for each symbology:
Symbology
Suffix
Symbology
Suffix
EAN 8
EAN 13
UPC A
UPC E
0C
16
0D
0A
Code 39
Interleaved 2 of 5
Code 128
Code 39
00
00
00
00
0A
0D
18
0A
0B
0B
0B
0B
IBM Secondary Interface
On some older IBM cash registers, it may be necessary to disable the secondary or management interface. In particular, it has been found necessary on IBM registers using the 4690 V2R4 operating system. The
following bar codes are used for this purpose. Default = Enable Secondary
Interface.
*Enable Secondary Interface
Disable Secondary Interface
2-4
USB PC or Macintosh Keyboard
Scan one of the following codes to program the scanner for USB PC Keyboard or USB Macintosh Keyboard. Scanning these codes also adds a CR
and LF.
USB Keyboard (PC)
USB Keyboard (Mac)
USB Japanese Keyboard (PC)
USB HID
Scan the following code to program the scanner for USB HID bar code
scanners.
USB HID Bar Code Scanner
HID Fallback Mode
If you attempt to set a USB interface for your scanner, but the setup fails on
the host system, you can program the scanner to fall back to a HID keyboard interface after a set length of time. For example, if the scanner is
configured for Serial Emulation Mode, but the host system does not have
the correct driver, the scanner would fail. If you set the HID Fallback Mode
for a set length of time, for example, 5 minutes, the scanner would change
to a HID keyboard interface after 5 minutes of trying to configure as serial
emulation.
A unique beep sequence indicates that this mode has been entered. While
in HID Fallback Mode, the scanner will not scan normal bar codes and
sounds a unique beep sequence that indicates the scanner is in Fallback
Mode. Menu codes can still be scanned while in HID Fallback Mode, allowing you to change the scanner’s programming.
2-5
Scan the bar code below, then set the length for the HID Fallback (from 060 minutes) by scanning digits from the Programming Chart, then scanning
Save. Default = 5 minutes.
HID Fallback Mode
USB Serial Commands
USB Serial Emulation
Scan one of the following codes to program the scanner to emulate a regular RS232-based COM Port. If you are using a Microsoft® Windows® PC,
you will need to download a driver from the Honeywell website
(www.honeywellaidc.com). The driver will use the next available COM Port
number. Apple® Macintosh computers recognize the scanner as a USB
CDC class device and automatically uses a class driver.
Scanning either of these codes also adds a CR and LF.
USB Serial Emulation for
Windows XP, Windows Server
2003, and later
USB Serial Emulation for Windows 2000
Note: No extra configuration (e.g., baud rate) is necessary.
CTS/RTS Emulation
CTS/RTS Emulation On
* CTS/RTS Emulation Off
2-6
ACK/NAK Mode
ACK/NAK Mode On
* ACK/NAK Mode Off
Communication Timeout
This allows you to set the length (in milliseconds) for a timeout for the host
ACK/NAK response. Scan the bar code below, then set the timeout (from
0-65535 milliseconds) by scanning digits from the Programming Chart,
then scanning Save. Default = 2000 ms.
Communication Timeout
Timeout Retries
This setting limits the number of Communication Timeout retries. If the
Timeout Retries is set to 0, the transmission is terminated after the initial Communication Timeout. Scan the bar code below, then set the
number of retries (from 0-255) by scanning digits from the
Programming Chart, then scanning Save. (5 is the recommended setting.) Default = 0.
Timeout Retries
2-7
Communication Timeout Beeper
This selection programs the scanner to issue an error beep when a
communication timeout has occurred. The error beep sound is programmed using Number of Beeps – Error (page 4-4). Default = On.
Off
* On
NAK Retries
This selection limits the number of NAK retries that can occur in ACK/NAK
mode. Scan the bar code below, then set the number of retries (from 0255) by scanning digits from the Programming Chart, then scanning Save.
(5 is the recommended setting.) Default = 0, or disabled.
NAK Retries
Support BEL/CAN in ACK/NAK
This protocol responds to  and  commands when in ACK/
NAK mode. The scanner sounds an error tone when a  command is
sent from the host.  terminates the transmission. Default = BEL/
CAN Off.
BEL/CAN On
* BEL/CAN Off
2-8
Verifone® Ruby Terminal Default Settings
Scan the following Plug and Play code to program the scanner for a Verifone
Ruby terminal. This bar code sets the baud rate to 1200 bps and the data format to 8 data bits, Mark parity, 1 stop bit and RTS/CTS no timeout. It also adds
a line feed (LF) suffix and programs the following prefixes for each symbology:
Symbology
Prefix
UPC-A
UPC-E
EAN-8
EAN-13
FF
Verifone Ruby Settings
Note: If you are having unexpected results with this programming code, scan
the Activate Defaults bar code on page 1-10 first, then scan the
programming code above.
Gilbarco® Terminal Default Settings
Scan the following Plug and Play code to program the scanner for a Gilbarco
terminal. This bar code sets the baud rate to 2400 bps and the data format to 7
data bits, even parity, 2 stop bits. It also adds a carriage return (CR) suffix and
programs the following prefixes for each symbology:
Symbology
Prefix
UPC-A
UPC-E
EAN-8
EAN-13
E0
FF
Gilbarco Settings
Note: If you are having unexpected results with this programming code, scan
the Activate Defaults bar code on page 1-10 first, then scan the
programming code above.
2-9
Honeywell Bioptic Aux Port Configuration
Scan the following Plug and Play code to program the scanner for a Honeywell
bioptic scanner auxiliary port configuration. This bar code sets the baud rate to
38400 bps and the data format to 8 data bits, no parity, 1 stop bit. Character
RTS/CTS with timeout and 232 ACK/NAK are also enabled.
Honeywell Bioptic Settings
Note: If you are having unexpected results with this programming code, scan
the Activate Defaults bar code on page 1-10 first, then scan the
programming code above.
Datalogic™ Magellan© Bioptic Aux Port
Configuration
Scan the following Plug and Play code to program the scanner for a Datalogic
Magellan bioptic scanner auxiliary port configuration. This bar code sets the
baud rate to 9600 bps and the data format to 8 data bits, no parity, 1 stop bit.
Datalogic Magellan Bioptic Settings
Note: If you are having unexpected results with this programming code, scan
the Activate Defaults bar code on page 1-10 first, then scan the
programming code above.
NCR Bioptic Aux Port Configuration
Scan the following Plug and Play code to program the scanner for an NCR bioptic scanner auxiliary port configuration. This bar code sets the baud rate to
9600 bps and the data format to 7 data bits, Even parity, 1 stop bit and Message
RTS/CTS with timeout. The following prefixes are programmed for each symbology:
Symbology
Prefix
Symbology
Prefix
UPC-A
UPC-E
EAN-8
E0
FF
Code 39
Interleaved 2 of 5
All other bar
codes
B1
B2
B3
EAN-13
2 - 10
NCR Bioptic Settings
Note: If you are having unexpected results with this programming code, scan
the Activate Defaults bar code on page 1-10 first, then scan the
programming code above.
Wincor Nixdorf Terminal Default Settings
Scan the following Plug and Play code to program the scanner for a Wincor Nixdorf terminal. This bar code sets the baud rate to 9600 bps and the data format
to 8 data bits, no parity, 1 stop bit.
Wincor Nixdorf Terminal Settings
Note: If you are having unexpected results with this programming code, scan
the Activate Defaults bar code on page 1-10 first, then scan the
programming code above.
2 - 11
Wincor Nixdorf Beetle™
Terminal Default Settings
Scan the following Plug and Play code to program the scanner for a Wincor Nixdorf Beetle terminal. The following prefixes are programmed for each symbology:
Symbology
Prefix
Code 128
Code 93
Codabar
UPC-A
UPC-E
EAN-8
A0
Symbology
EAN-13
GS1-128
Interleaved 2 of 5
Plessey
Straight 2 of 5 IATA
All other bar codes
Prefix
Wincor Nixdorf Beetle Settings
Note: If you are having unexpected results with this programming code, scan
the Activate Defaults bar code on page 1-10 first, then scan the
programming code above.
2 - 12
Keyboard Country Layout
Scan the appropriate country code below to program the keyboard layout for
your country or language. As a general rule, the following characters are supported, but need special care for countries other than the United States:
@ | $ # { } [ ] = / ‘ \ < > ~
* United States
Arabic
Belgium
Chinese
Finland
France
Germany
Hungary
IBM Financial
Italy
Japan ASCII
Korea
2 - 13
Keyboard Country (continued)
Russia
Slovenia
Spain
Switzerland (German)
Thailand
Turkey Q
United Kingdom
Vietnam
Keyboard Wedge Modifiers
ALT Mode
If your bar code contains special characters from the extended ASCII chart
for example, an e with an accent grave (è), you will use ALT Mode. (See
Extended ASCII Characters on page A-5.)
Note: Scan the ALT mode bar code after scanning the appropriate
Keyboard Country code.
2 - 14
If your keystrokes require using the ALT key and 3 characters, scan the 3
Characters bar code. If your keystrokes require the ALT key and 4 characters, scan the 4 Characters bar code. The data is then output with the special character(s). Default = Off.
* Off
3 Characters
4 Characters
Keyboard Style
This programs keyboard styles, such as Caps Lock and Shift Lock. If you
have used Keyboard Conversion settings, they will override any of the following Keyboard Style settings. Default = Regular.
Regular is used when you normally have the Caps Lock key off.
* Regular
Caps Lock is used when you normally have the Caps Lock key on.
Caps Lock
Shift Lock is used when you normally have the Shift Lock key on (not common to U.S. keyboards).
Shift Lock
2 - 15
Autocaps via NumLock bar code should be scanned in countries (e.g.,
Germany, France) where the Caps Lock key cannot be used to toggle Caps
Lock. The NumLock option works similarly to the regular Autocaps, but
uses the NumLock key to retrieve the current state of the Caps Lock.
Autocaps via NumLock
Emulate External Keyboard should be scanned if you do not have an
external keyboard (IBM AT or equivalent).
Emulate External Keyboard
Note: After scanning the Emulate External Keyboard bar code, you must
power cycle your computer.
Keyboard Conversion
Alphabetic keyboard characters can be forced to be all upper case or all
lowercase. So if you have the following bar code: “abc569GK,” you can
make the output “ABC569GK” by scanning Convert All Characters to
Upper Case, or to “abc569gk” by scanning Convert All Characters to
Lower Case. These settings override Keyboard Style selections.
Default = Keyboard Conversion Off.
* Keyboard Conversion Off
Convert All Characters to Upper
Case
Convert All Characters to Lower
Case
Keyboard Modifiers
This modifies special keyboard features, such as CTRL+ ASCII codes and
Turbo Mode.
2 - 16
Control + ASCII Mode On: The scanner sends key combinations for ASCII
control characters for values 00-1F (refer to the ASCII chart for NonPrintable Characters, page A-4). Windows is the preferred mode. All keyboard country codes are supported. DOS mode is a legacy mode, and it
does not support all keyboard country codes. New users should use the
Windows mode.
Windows Mode Prefix/Suffix Off: The scanner sends key combinations
for ASCII control characters for values 00-1F (refer to the ASCII chart for
Non-Printable Characters, page A-4), but it does not transmit any prefix or
suffix information.
Default = Control + ASCII Mode Off.
Windows Mode Control + ASCII
Mode On
* Control + ASCII Mode Off
DOS Mode Control + ASCII Mode
On
Windows Mode Prefix/Suffix Off
Numeric Keypad Mode: Sends numeric characters as if entered from a
numeric keypad. Default = Off.
Numeric Keypad Mode On
* Numeric Keypad Mode Off
Inter-Scan Code Delay
When your keyboard detects that any key is being pressed, released, or
held down, the keyboard sends a packet of information known as a “scan
code” to your computer. This selection allows you to adjust the delay
2 - 17
between scan codes. Set the length (in milliseconds) for a delay by scanning the bar code below, then setting the delay (from 1-30) by scanning digits from the Programming Chart, then scanning Save. Default = 0 (800 µs).
Inter-Scan Code Delay
 Break Character
When your keyboard detects that any key is being pressed, released, or
held down, the keyboard sends a packet of information known as a “scan
code” to your computer. There are two different types of scan codes:
“make codes” and “break codes.” A make code is sent when a key is
pressed or held down. A break code is sent when a key is released. The
following selections allow you to suppress or transmit the character
sequence of the break code. Default = Transmit.
Suppress
* Transmit
Keyboard Wedge Defaults
If you want the custom keyboard wedge default settings restored to your
scanner, scan the Keyboard Wedge Defaults bar code below. This resets
the scanner to the custom default settings (see Setting Custom Defaults on
page 1-9). If there are no custom defaults, it will reset the scanner to the
factory default settings. Any settings that have not been specified through
the custom defaults will be defaulted to the factory default settings.
Keyboard Wedge Defaults
2 - 18
RS232 Modifiers
RS232 Baud Rate
Baud Rate sends the data from the scanner to the terminal at the specified
rate. The host terminal must be set for the same baud rate as the scanner.
Default = 9600.
300
600
1200
2400
4800
* 9600
19200
38400
57,600
115,200
2 - 19
RS232 Word Length: Data Bits, Stop Bits, and Parity
Data Bits sets the word length at 7 or 8 bits of data per character. If an
application requires only ASCII Hex characters 0 through 7F decimal (text,
digits, and punctuation), select 7 data bits. For applications that require
use of the full ASCII set, select 8 data bits per character. Default = 8.
Stop Bits sets the stop bits at 1 or 2. Default = 1.
Parity provides a means of checking character bit patterns for validity.
Default = None.
7 Data, 1 Stop, Parity Even
7 Data, 1 Stop, Parity None
7 Data, 1 Stop, Parity Odd
7 Data, 2 Stop, Parity Even
7 Data, 2 Stop Parity None
7 Data, 2 Stop, Parity Odd
8 Data, 1 Stop, Parity Even
* 8 Data, 1 Stop, Parity None
8 Data, 1 Stop, Parity Odd
7 Data, 1 Stop, Parity Space
2 - 20
7 Data, 2 Stop, Parity Space
8 Data, 1 Stop, Parity Space
7 Data, 1 Stop, Parity Mark
7 Data, 2 Stop, Parity Mark
8 Data, 1 Stop Parity Mark
RS232 Handshaking
RS232 Handshaking allows control of data transmission from the scanner
using software commands from the host device. When RTS/CTS is
turned Off, no data flow control is used.
Flow Control, No Timeout: The scanner asserts RTS when it has data to
send, and will wait indefinitely for CTS to be asserted by the host.
Character-Based Flow Control, No Timeout: The scanner asserts RTS
when it has a character to send, and will wait indefinitely for CTS to be
asserted by the host
Two-Direction Flow Control: The scanner asserts RTS when it is OK for
the host to transmit. The host asserts CTS when it is OK for the device to
transmit.
Flow Control with Timeout: The scanner asserts RTS when it has data
to send and waits for a delay (see RS232 Timeout on page 2-22) for CTS to
be asserted by the host. If the delay time expires and CTS is not asserted,
the device transmit buffer is cleared and scanning may resume.
Character-Based Flow Control with Timeout: The scanner asserts RTS
when it has a character to send and waits for a delay (see RS232 Timeout
on page 2-22) for CTS to be asserted by the host. If the delay time expires
2 - 21
and CTS is not asserted, the device transmit buffer is cleared and scanning
may resume.
Default = RTS/CTS Off.
Flow Control, No Timeout
Character-Based Flow Control,
No Timeout
Two-Direction Flow Control
Flow Control with Timeout
Character-Based Flow Control
with Timeout
* RTS/CTS Off
RS232 Timeout
When using Flow Control with Timeout, you must program the length of the
delay you want to wait for CTS from the host. Set the length (in milliseconds) for a timeout by scanning the bar code below, then setting the timeout (from 1-5100 milliseconds) by scanning digits from the Programming
Chart, then scanning Save. Default = 1000 ms (1 second).
RS232 Timeout
XON/XOFF
Standard ASCII control characters can be used to tell the scanner to start
sending data (XON/XOFF On) or to stop sending data (XON/XOFF Off).
When the host sends the XOFF character (DC3, hex 13) to the scanner,
2 - 22
data transmission stops. To resume transmission, the host sends the XON
character (DC1, hex 11). Data transmission continues where it left off
when XOFF was sent. Default = XON/XOFF Off.
XON/XOFF On
* XON/XOFF Off
ACK/NAK
After transmitting data, the scanner waits for an ACK character (hex 06) or
a NAK character (hex 15) response from the host. If ACK is received, the
communications cycle is completed and the scanner looks for more bar
codes. If NAK is received, the last set of bar code data is retransmitted and
the scanner waits for ACK/NAK again. Turn on the ACK/NAK protocol by
scanning the ACK/NAK On bar code below. To turn off the protocol, scan
ACK/NAK Off. Default = ACK/NAK Off.
ACK/NAK On
* ACK/NAK Off
Communication Timeout
This allows you to set the length (in milliseconds) for a timeout for the host
ACK/NAK response. Scan the bar code below, then set the timeout (from
1-65535 milliseconds) by scanning digits from the Programming Chart,
then scanning Save. Default = 2000 ms.
Communication Timeout
Timeout Retries
This setting limits the number of Communication Timeout retries. If the
Timeout Retries is set to 0, the transmission is terminated after the initial Communication Timeout. Scan the bar code below, then set the
2 - 23
number of retries (from 0-255) by scanning digits from the
Programming Chart, then scanning Save. (5 is the recommended setting.) Default = 0.
Timeout Retries
Communication Timeout Beeper
This selection programs the scanner to issue an error beep when a
communication timeout has occurred. The error beep sound is programmed using Number of Beeps – Error (page 4-4). Default = On.
Off
* On
NAK Retries
This selection limits the number of NAK retries that can occur in ACK/NAK
mode. Scan the bar code below, then set the number of retries (from 0255) by scanning digits from the Programming Chart, then scanning Save.
(5 is the recommended setting.) Default = 0, or disabled.
NAK Retries
2 - 24
Support BEL/CAN in ACK/NAK
This protocol responds to  and  commands when in ACK/
NAK mode. The scanner sounds an error tone when a  command is
sent from the host.  terminates the transmission. Default = BEL/
CAN Off.
BEL/CAN On
* BEL/CAN Off
RS232 Defaults
If you want the custom RS232 default settings restored to your scanner,
scan the RS232 Defaults bar code below. This resets the scanner to the
custom default settings (see Setting Custom Defaults on page 1-9). If
there are no custom defaults, it will reset the scanner to the factory default
settings. Any settings that have not been specified through the custom
defaults will be restored to the factory default settings.
RS232 Defaults
NCR Modifiers
NCR ACK/NAK
This is an NCR communication protocol for ACK/NAK processing. Default
= NCR ACK/NAK Off.
* NCR ACK/NAK Off
NCR ACK/NAK On
2 - 25
Block Check Character
When this selection is set to Transmit, the NCR Block Check Character
(BCC) is expected with incoming messages and transmitted with outgoing
messages. Default = Transmit.
* Transmit
Don’t Transmit
NCR Prefix
This selection allows you to program an NCR-specific prefix. Refer to the
ASCII Conversion Chart (Code Page 1252) on page A-4 to find the hex
equivalent for the characters you want for the NCR prefix (typically, 02 for
STX). Scan the bar code below, then set the hex number (from 0-FF) by
scanning digits from the Programming Chart, then scanning Save. Default
= 0.
NCR Prefix
NCR Suffix
This selection allows you to program an NCR-specific suffix. Refer to the
ASCII Conversion Chart (Code Page 1252) on page A-4 to find the hex
equivalent for the characters you want for the NCR suffix (typically, 03 for
ETX). Scan the bar code below, then set the hex number (from 0-FF) by
scanning digits from the Programming Chart, then scanning Save. Default
= 0.
NCR Suffix
2 - 26
NCR Prefix/Suffix
When set to Transmit, both the NCR prefix and suffix are transmitted with
bar codes. Usually, prefixes and suffixes are programmed using the Data
Editing selections (see Data Editing beginning on page 5-1), however, the
following commands override any other prefix/suffix settings. Default =
Don’t Transmit.
Transmit
* Don’t Transmit
NCR NOF (Not-on-File) Error
A scanner receives an NOF (Not on File) command from the POS whenever it cannot cross-reference the bar code to a price parameter. When set
to On, the error tone sounds (set via Number of Beeps – Error, page 4-4)
for an NOF, and disables the scanner while the cashier looks up the price
manually. When set to Off, no sound is emitted for an NOF. Default = Off.
On
* Off
Scanner to Bioptic Communication
The following settings are used to set up communication between Honeywell
scanners and bioptic scanners.
Note: The scanner’s baud rate must be set to 38400 and the RS232 Timeout
must be set to 3000 in order to communicate with a bioptic scanner. See
RS232 Modifiers on page 2-19, and RS232 Timeout on page 2-22 for
further information.
2 - 27
Scanner-Bioptic Packet Mode
Packet Mode On must be scanned to set the scanner’s format so it is compatible with a bioptic scanner. Default = Packet Mode Off.
* Packet Mode Off
Packet Mode On
ACK/NAK
After transmitting data, the scanner waits for an ACK character (hex 06) or
a NAK character (hex 15) response from the host. If ACK is received, the
communications cycle is completed and the scanner looks for more bar
codes. If NAK is received, the last set of bar code data is retransmitted and
the scanner waits for ACK/NAK again. Turn on the ACK/NAK protocol by
scanning the ACK/NAK On bar code below. To turn off the protocol, scan
ACK/NAK Off. Default = ACK/NAK Off.
ACK/NAK On
* ACK/NAK Off
Communication Timeout
This allows you to set the length (in milliseconds) for a timeout for the host
ACK/NAK response. Scan the bar code below, then set the timeout (from
1-65535 milliseconds) by scanning digits from the Programming Chart,
then scanning Save. Default = 2000 ms.
Communication Timeout
2 - 28
3
Cordless System Operation
Note: This chapter applies only to cordless scanning systems. It does not apply
to corded scanners.
How the Cordless Charge Base Works
A cordless charge base provides the link between the cordless scanner and the
host system. The base contains an interface assembly and an RF communication module. The RF communication module performs the data exchange
between the cordless scanner and the interface assembly. The control assembly coordinates the central interface activities including: transmitting/receiving
commands and data to/from the host system, performing software activities
(parameter menuing, visual indicator support, power-on diagnostics), and data
translation required for the host system.
The cordless charge base is also a scanner’s battery charger. Refer to
Charging Information, page 3-4, for additional information.
Linking the Scanner to a Charge Base
Turn off power before connecting a base, then power up the computer once the
base is fully connected. When the base is connected and powered up, put the
scanner in the base to establish a link. The green LED on the base flashes to
indicate the scanner’s battery is charging.
If the scanner and base have previously been linked, you do not receive any
feedback. If this is the first time that the scanner and base are linked, both
devices emit a short chirp when their radios link. That indicates that the scanner is linked to the base.
Scanner
Page Button
Base LEDs
Charge Base
3-1
To determine if your cordless system is set up correctly, scan one of the sample
bar codes in the back of this manual. If the scanner provides a single good read
beep and the green LED lights, the scanner has successfully linked to the base.
If you receive an error tone and the red LED lights, the scanner has not linked to
the base. Refer to page 12-5 for troubleshooting information.
Communication Between the Cordless System
and the Host
The cordless scanner provides immediate feedback in the form of a “good read”
indication (a green LED on the scanner and an audible beep) after a bar code is
scanned correctly and the base has acknowledged receiving the data. This is
possible since the cordless system provides two-way communication between
the scanner and the base.
When data is scanned, the data is sent to the host system via the base. The
cordless scanner recognizes data acknowledgement (ACK) from the base. If it
cannot be determined that the data has been properly sent to the base, the
scanner issues an error indication. You must then check to see if the scanned
data was received by the host system.
1) Good Read
2) ACK
from
base
3) Base sends
data to host
RF (Radio Frequency) Module Operation
The cordless system uses a two-way Bluetooth® radio to transmit and receive
data between the scanner and the base. Designed for point-to-point and multipoint-to-single point applications, the radio operates using a license free ISM
band. This band sends relatively small data packets at a fast data rate over a
radio signal with randomly changing frequencies. This makes the cordless system highly responsive to a wide variety of data collection applications and resis-
3-2
tant to noisy RF environments. The Bluetooth Class 2 power level provides a
communication range of 33 feet (10m) between the scanner and base, depending on the environment.
System Conditions
The components of the cordless system interact in specific ways as you associate the scanner with its base, as you move a scanner out of range, or bring a
scanner back in range. The following information explains the cordless system
operating conditions.
Linking Process
Once a scanner is placed into a cordless charge base, the scanner’s battery charge status is checked, and software automatically detects the scanner and links it to the base depending on the selected link mode.
Scanner Is Out of Range
The cordless scanner is in communication with its base, even when it is not
transmitting bar code data. Whenever the scanner can’t communicate with
the base for a few seconds, it is out of range. If the scanner is out of range
and you scan a bar code, the scanner issues an error tone indicating no
communication with the base. A cordless charge base can also sound an
alarm. Refer to Out-of-Range Alarm, page 3-12.
Scanner Is Moved Back Into Range
The scanner relinks if the scanner or the base have been reset, or the
scanner comes back into range. If the scanner relinks, you will hear a single chirp when the relinking process is complete. Refer to Out-of-Range
Alarm on page 3-12 for further information.
Out of Range and Back into Range
with Batch Mode On
The scanner may store a number of symbols (approximately 500 U.P.C.
symbols; others may vary) when it is out of range and then send them to
the base when back in range (see Batch Mode on page 3-13).
You will not hear a communication error tone in this mode, but you will hear
a short buzz when you press the button if the radio communication is not
working. Once the radio connection is made, the scanner produces a
series of beeps while the data is being transferred to the base.
Page Button
When you press the Page button on the base, the scanner associated with
that base will begin beeping (3 short and 1 long beep). If you press the button on a scanner that is beeping in response, or press the Page button on
the base a second time, the scanner will stop beeping. See Paging on
page 3-8 for further information about Page Button settings.
3-3
About the Battery
There is a danger of explosion if the batteries are incorrectly replaced.
Replace the batteries with only the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to
the recycle program for batteries as directed by the governing agency
for the country where the batteries are to be discarded.
Power is supplied to the cordless scanner by a rechargeable battery that is integrated in the scanner handle. Batteries are shipped approximately 30% to 60%
charged. The battery should be charged for a minimum of 4 hours before initial
use to ensure optimal performance.
Voyager 1202 Battery Removal
Charging Information
The battery is designed to charge while the scanner is positioned in the
cordless base unit. Refer to Base LED Sequences and Meaning, page 37, for an interpretation of the Charge Status indicators. Refer to Charge
Only Mode (page 3-10) if you need to charge a scanner without linking it to
the base.
3-4
The model Voyager 1202g is designed for use with Honeywell battery pack
model 100000495 (Li-ion 3.7Vdc, 7.4 watt hour).
Place the scanner in the base that is connected to an appropriate power
supply. Use only a Listed Limited Power Source (LPS) or Class 2 type
power supply with output rated 5 to 5.2Vdc, 1A.
Note: If you are powering the base through the interface cable (for
example, a USB cable) and not using an external power supply
plugged into the aux port, the current available for charging is
reduced and the charge time is increased.
Battery Recommendations
• The battery is a lithium ion cell and can be used without a full charge, and
can also be charged without fully discharging, without impacting the
battery life. There is no need to perform any charge/discharge
conditioning on this type of battery.
• Keep the base connected to power when the host is not in use.
• Replace a defective battery immediately since it could damage the
scanner.
• Although your battery can be recharged many times, it will eventually be
depleted. Replace it after the battery is unable to hold an adequate
charge.
• If you are not sure if the battery or charger is working properly, send it to
Honeywell International Inc. or an authorized service center for
inspection. Refer to Customer Support on page 13-1 for additional
information.
Caution:
The model CCB00-010BT base is designed for use with the
Honeywell model Voyager 1202g scanner. Use of any nonHoneywell battery may result in damage not covered by the
warranty.
Safety Precautions for Lithium Batteries
•
•
•
•
•
•
•
Do not place batteries in fire or heat the batteries.
Do not store batteries near fire or other high temperature locations.
Do not store or carry batteries together with metal objects.
Do not expose batteries to water or allow the batteries to get wet.
Do not connect (short) the positive and negative terminals, of the
batteries, to each other with any metal object.
Do not pierce, strike or step on batteries or subject batteries to strong
impacts or shocks.
Do not disassemble or modify batteries.
3-5
!
Caution:
Danger of explosion if batteries are incorrectly replaced.
Dispose of used batteries according to the recycle program for
batteries as directed by the governing agency for the country
where the batteries are to be discarded.
Proper Disposal of the Battery
When the battery has reached the end of its useful life,
the battery should be disposed of by a qualified recycler
or hazardous materials handler. Do not incinerate the
battery or dispose of the battery with general waste
materials. You may send the scanner’s battery to us.
(postage paid). The shipper is responsible for complying
with all federal, state, and local laws and regulations
related to the packing, labeling, manifesting, and shipping of spent batteries. Contact the Product Service Department (page 131) for recycling or disposal information. Since you may find that your cost
of returning the batteries significant, it may be more cost effective to locate
a local recycle/disposal company.
Flash Updates
The scanner can be flashed either in the base or out of the base, however, it is
recommended that you flash the scanner while it is in the base. Flash updates
cannot be completed when the scanner is out of the base and the battery is low,
or when the scanner is out of range.
Beeper and LED Sequences and Meaning
The scanner contains LEDs on the top that indicate linking status, decoding
state, and battery condition. The base has LEDs on the front that indicate its
power up, communication, and battery charge condition. The unit’s audible indicators have meaning as well. The following table lists the indication and cause
of the LED illumination and beeps for the scanner and charge base.
Scanner LED Sequences and Meaning
Note: Pressing the button on the scanner causes the LED to glow red until
it communicates successfully with the base.
LED Indication
Beeper Indication
Cause
Normal Operation
Red Flash
Green Flash
None
1 beep
Battery low
Successful
communication or linking
Failed communication
Red, blinking
Menu Operation
3-6
Razz or error tone
LED Indication
Beeper Indication
Cause
Green Flash
Red, blinking
2 beeps
Razz or error tone
Successful menu change
Unsuccessful menu
change
Base LED Sequences and Meaning
The base contains a red LED that indicate the status of the unit and verifies
its communication with the host system. The base also has a green LED
that indicates the scanner battery charge condition.
Red LED - Host Communication
Red LED
Communication Condition
Off
USB suspend
On continuously
Power on, system idle
Short blinks. Occurs while transferring
data to/from the RF module or the host
port.
Receiving data
Green LED - Scanner Battery
Green LED
Charge Condition
Off
Battery not detected or charge
suspended
Slow flash, 1 second on, 1 second off
Pre-charge and charging
On continuously
Charge complete
Fast flash, 300 mSec on, 300 mSec off
Charge Error
Base Power Communication Indicator
To display the power indicator on the base, scan the Base Power Communication Indicator On bar code. To turn off the power indicator, scan the
Off bar code. Default = On.
* Base Power Communication
Indicator On
Base Power Communication
Indicator Off
3-7
Reset Scanner
Scanning this bar code reboots the scanner and causes it to relink with the
base.
Reset Scanner
Scanning While in Base Cradle
If you want to be able to scan bar codes while the scanner is in the base cradle,
scan the following Scanning in Cradle On bar code. If you want to only allow
scanning when the scanner is out of the base cradle, scan Scanning in Cradle
Off. Default = Scanning in Cradle On.
Scanning in Cradle Off
* Scanning in Cradle On
Note: When Scanning in Cradle Off is selected, the scanner will not scan any
bar codes while it is in the base cradle. It will only scan when removed
from the base.
Paging
Paging Mode
By default, the paging button on the base pages the scanner associated
with that base. If you want the paging button on your base to be disabled,
scan the following Paging Mode Off bar code. When Paging Mode is off,
the base will no longer page the scanner when the button is pressed. The
3-8
red LED on the base will remain lit to indicate that Paging Mode is off. (This
light will go out when the button is pressed, then back on when it’s
released.) Default = Paging Mode On.
* Paging Mode On
Paging Mode Off
Paging Pitch
When you press the Page button on the base, the scanner associated with
that base will begin beeping (see Page Button on page 3-3). You can set
the pitch of the paging beep for the scanner by scanning one of the following bar codes. Default = Low.
* Low (1000 Hz)
Medium (3250 Hz)
High (4200 Hz)
Error Indicators
Scanner Address
Scan the following bar code to determine the address of the scanner you are
using.
Scanner Address
3-9
Base Address
Scan the following bar code to determine the address of the base you are using.
Base Address
Scanner Modes
The Voyager is capable of working with Bluetooth devices other than the
CCB00-010BT charge base.
Charge Only Mode
There may be times when you want to charge your scanner, but not link to
the base. For example, if a scanner is linked to a Bluetooth device and you
need to charge the scanner, but want to retain your existing link.
In order to program the base for Charge Only Mode, you must link a scanner to it. Once the scanner is linked to the base, scan the Charge Only
Mode bar code. Any subsequent scanners placed in that base will charge
without linking to it. The scanner used to program the base remains linked
to the base. To unlink this scanner, scan Unlink Scanner on page 3-11.
Charge Only Mode
Note: When in Charge Only Mode, the scanner periodically wakes up and
beeps. See "Power Up Beeper" on page 4-1 to change this setting.
If you want to charge a scanner and link to the base, use Charge and Link
Mode. If the base is programmed for Charge Only Mode, you must link a
scanner to it first in order to program it for Charge and Link Mode. Scan
the linking bar code on the base to link the scanner, then scan Charge and
Link Mode. Default = Charge and Link Mode.
* Charge and Link Mode
3 - 10
Linked Modes
Locked Link Mode and Open Link Mode are the link modes that accommodate different applications. Scan the appropriate bar codes included in the
Open Link and Locked Link Mode explanations that follow to switch from
one mode to another. Default = Open Link Mode.
Locked Link Mode - Single Scanner
If you link a scanner to a base using the Locked Link Mode, other
scanners are blocked from being linked if they are inadvertently placed
into the base. If you do place a different scanner into a base, it will
charge the scanner, but the scanner will not be linked.
Locked Link Mode
(Single Scanner)
To use a different scanner, you need to unlink the original scanner by
scanning the Unlink Scanner bar code. (See Scanner Modes, page 310.)
Open Link Mode - Single Scanner
When newly shipped or defaulted to factory settings, a scanner is not
linked to a base. A link is established when the scanner is placed into
a base. When in Open Link Mode, a new link is established when a
new scanner is placed in the base. Each time a scanner is placed into
a base, the scanner becomes the linked to the base and the old scanner is unlinked.
* Open Link Mode
(Single Scanner)
Unlinking the Scanner
If a base has a scanner linked to it, that scanner must be unlinked before a new
scanner can be linked. Once the previous scanner is unlinked, it will no longer
communicate with the base. To unlink the scanner from a base, scan the following Unlink Scanner bar code.
Unlink Scanner
3 - 11
Override Locked Scanner
If you need to replace a broken or lost scanner that is linked to a base, scan the
following Override Locked Scanner bar code with a new scanner and place
that scanner in the base. The locked link will be overridden, the broken or lost
scanner’s link with the base will be removed, and the new scanner will be linked.
Override Locked Scanner
(Single Scanner)
Out-of-Range Alarm
If your scanner is out range of the base, an alarm sounds from the scanner.
The alarm stops when the scanner is moved closer to the base, when the base
connects to another scanner, or when the alarm duration expires.
Note: If you are out of range when you scan a bar code, you will receive an error
tone even if you do not have the alarm set. You receive the error tone
since the data could not be communicated to the base or the host.
Alarm Sound Type
Set the alarm type for the scanner by scanning the following appropriate
bar code. If the alarm is on, the scanner will emit 3 long, high pitched
beeps. Default = Alarm Off.
* Alarm Off
Alarm On
Alarm Duration
To set the the length of time you want the Out-of-Range alarm to sound,
scan the following bar code and then set the time-out duration (from 0-3000
seconds) by scanning digits on the Programming Chart inside the back
cover, then scanning Save. Default = 1 sec.
Scanner Alarm Duration
3 - 12
Scanner Power Time-Out Timer
Note: Scanner Power Time-out Timer only applies to cordless systems. It does
not apply to corded scanners.
When there is no activity within a specified time period, the scanner enters low
power mode. Scan the appropriate scanner power time-out bar code to change
the time-out duration (in seconds).
Note: Scanning zero (0) is the equivalent of setting no time-out.
If the scanner is not activated during the timer interval, the scanner goes into
power down mode. Whenever the scanner is activated, the timer is reset. If
Scanning While in Base Cradle (page 3-8) is disabled, the scanner will still go
into power down mode. Default = 3600 seconds.
0 seconds
200 seconds
400 seconds
900 seconds
* 3600 seconds
7200 seconds
Note: When the scanner is in power down mode, pull the trigger to power the
unit back up. There will be a set of power up beeps and a delay of up to
a few seconds for the radio to join. The scanner will then be ready to use.
Batch Mode
Batch mode is used to store bar code data when a scanner is out of range of its
base, or when performing inventory. The data is transmitted to the base once
the scanner is back in range or when the records are manually transmitted.
3 - 13
Automatic Batch Mode stores bar code data when the scanner is out of range
of the base. The data is automatically transmitted to the base once the scanner
is back in range. When the scanner’s buffer space is full, any bar codes
scanned generate an error tone. In order to scan bar codes again, the scanner
must be moved back into range of the base so data can be transmitted.
Inventory Batch Mode stores bar code data, whether or not you are in range of
the base. To transmit the stored data to the base, either place the scanner in
the base, or scan Transmit Inventory Records (page 3-19). When the scanner’s
buffer space is full, any bar codes scanned generate an error tone. In order to
scan bar codes again, the data must be transmitted to the base.
Default = Batch Mode Off.
* Batch Mode Off
Automatic Batch Mode
Inventory Batch Mode
Batch Mode Beep
When scanning in Batch Mode, the scanner beeps every time a bar code is
scanned. When Batch Mode Beep is On, you will also hear a click when
each bar code is sent to the host. If you do not want to hear these clicks,
scan Batch Mode Beep Off. Default = Batch Mode Beep On.
Batch Mode Beep Off
* Batch Mode Beep On
Batch Mode Quantity
When in Inventory Batch Mode (page 3-14), you may wish to transmit the
number of multiple bar codes scanned, rather than a single bar code multiple times. For example, if you scan three bar codes called XYZ with Batch
Mode Quantity Off, when you transmit your data it will appear as XYZ
3 - 14
three times. Using Batch Mode Quantity On and the Quantity Codes
(page 3-16), you could output your data as “XYZ, 00003” instead. Default =
Batch Mode Quantity Off.
* Batch Mode Quantity Off
Batch Mode Quantity On
Entering Quantities
Quantity Codes (page 3-16) allow you to enter a quantity for the last item
scanned, up to 9999 (default = 1). Quantity digits are shifted from right to
left, so if a 5th digit is scanned, the 1st digit scanned is discarded and the
2nd, 3rd and 4th digits are moved to the left to accommodate the new digit.
For example, if the Quantity 5 bar code is scanned after the quantity has
been set to 1234, then the 1 is dropped, the quantity will be 2345.
Example: Add a quantity of 5 for the last item scanned.
1. Scan the item's bar code.
2. Scan the quantity 5 bar code.
Example: Add a quantity of 1,500 for the last item scanned.
1. Scan the item's bar code.
2. Scan the quantity 1 bar code.
3. Scan the quantity 5 bar code.
4. Scan the quantity 0 bar code.
5. Scan the quantity 0 bar code.
Example: Change a quantity of 103 to 10.
To correct an incorrect quantity, scan the quantity 0 bar code to replace the
incorrect digits, then scan the correct quantity bar codes.
1.
2.
3.
4.
Scan the quantity 0 bar code to change the quantity to 1030.
Scan the quantity 0 bar code to change the quantity to 0300.
Scan the quantity 1 bar code to change the quantity to 3001.
Scan the quantity 0 bar code to change the quantity to 0010.
3 - 15
Quantity Codes
3 - 16
Delete Last Code
If you want to delete the last bar code scanned when in Batch Mode, scan
Delete Last Code.
Delete Last Code
Record Counter
If you wish to add a record counter to each bar code scanned in Batch
Mode, scan Record Counter On. Your batch output would add a sequential number before each bar code, for example:
00001,bar code 1
00002,bar code 2
Default = Record Counter Off.
* Record Counter Off
Record Counter On
Total Records
If you wish to output the total number of bar codes scanned when in Batch
Mode, scan Total Records.
Total Records
3 - 17
Batch Mode Output Order
When batch data is transmitted, select whether you want that data sent as
FIFO (first-in first-out), or LIFO (last-in last-out).
Batch Mode FIFO
Batch Mode LIFO
Clear All Codes After Transmission
If you want to clear the scanner’s buffer of all data accumulated in Batch
Mode after the data has been transmitted to the host system, scan Clear
All Codes After Transmission. If you do not want the buffer cleared after
transmission, scan Don’t Clear All Codes After Transmission. Default =
Don’t Clear All Codes After Transmission.
* Don’t Clear All Codes After
Transmission
Clear All Codes After
Transmission
Clear All Codes
If you want to clear the scanner’s buffer of all data accumulated in Batch
Mode, scan Clear All Codes.
Clear All Codes
3 - 18
Transmit Records Automatically
If you are operating in Inventory Batch Mode (see Inventory Batch Mode on
page 3-14), you can transmit all stored data to the host system when the
scanner is placed in the base. If you don’t want the records transmitted
when the scanner is placed in the base, scan the Don’t Transmit Records
Automatically bar code. Default = Don’t Transmit Records Automatically.
* Don’t Transmit Records
Automatically
Transmit Records Automatically
Transmit Records to Host
If you are operating in Inventory Batch Mode (see Inventory Batch Mode on
page 3-14), and your scanner is set to Don’t Transmit Records Automatically, you must scan the following bar code to transmit all stored records to
the host system.
Transmit Inventory Records
3 - 19
Batch Mode Transmit Delay
Sometimes when accumulated scans are sent to the host system, the
transmission of those scans is too fast for the application to process. To
program a transmit delay between accumulated scans, scan one of the following delays. Default = Off.
Note: In most cases, a short (250 ms (milliseconds)) delay is ideal,
however, longer delays may be programmed. Contact Technical
Support (page 13-3) for additional information.
* Batch Mode Transmit Delay Off
(No Delay)
Batch Mode Transmit Delay Short
(250 ms)
Batch Mode Transmit Delay Medium
(500 ms)
Batch Mode Transmit Delay Long
(1000 ms)
Scanner Name
You may assign a name to each scanner you are using for identification purposes. The default name is “Voyager.”
Perform the rename operation using either the bar codes on page 3-21, or by
sending the serial command :Voyager:BT_NAMname. where name is the new
name for the scanner. If you wish to change the names of additional scanners,
link them to the base one at a time and repeat the :Voyager:BT_NAMname.
command for each scanner.
3 - 20
To rename scanners with sequential, numeric names, scan the following bar
codes. Scan the Reset code after each name change and wait for the scanner
to relink to the base.
0001
0002
0003
0004
0005
0006
0007
Reset
You may also scan the following Scanner Name bar code and scan up to 30
numbers and/or letters for the scanner name. For example, if you wanted to
name the linked scanner “312,” you would scan the following bar code, scan the
3, 1, and 2 bar codes on the Programming Chart inside the back cover of this
manual, then scan Save. Scan the Reset bar code and wait for the scanner to
relink to the base.
To output the name of the scanner, scan the following bar code. The name will
be output showing the product name, model number, and the scanner’s 10-digit
serial number.
Scanner Name
3 - 21
Using the Scanner with Bluetooth Devices
The scanner can be used either with the CCB00-010BT charge base or with
other Bluetooth devices. Those devices include personal computers and laptops.
Scanning the following Non-Base BT Connection bar code allows the scanner
to be used with other Bluetooth devices (e.g., PC/laptop). After you scan the
Non-Base BT Connection bar code, follow the instructions supplied with your
Bluetooth device to locate the scanner and connect to it.
Note: If you go out of range with your scanner, the scanner will not reconnect to
the Bluetooth device when it is back in range.
To relink to the charge base, scan the Base BT Connection bar code.
Non-Base BT Connection
Base BT Connection
Changing the Scanner’s Bluetooth PIN Code
Some devices require a PIN code as part of the Bluetooth security features. Your scanner’s default PIN is 0000, which you may need to enter the
first time you connect to your non-base Bluetooth device. To change the
PIN, scan the following bar code and then scan the appropriate numeric
bar codes from the Programming Chart inside the back cover of this manual. (The PIN code must be between 1 and 16 characters.) Scan Save to
save your selection. Default = 0000.
Bluetooth PIN
Minimizing Bluetooth/ISM Band Network Activity
The following settings can help you customize the relinking behavior of the
cordless system to obtain the best compromise between convenience and low
interference.
Note: ISM band refers to the 2.4 to 2.48 GHz frequency band used by wireless
networks, cordless phones, and Bluetooth.
3 - 22
Auto Reconnect Mode
Auto Reconnect controls whether or not the scanner automatically begins
the relink process when a loss of connection is detected. When the Auto
Reconnect On bar code is scanned, the scanner begins the relink process
immediately, without user intervention. Default = Auto Reconnect On.
* Auto Reconnect On
Auto Reconnect Off
The following table shows the results of the Auto Reconnect On and Off
settings:
Event
Auto Reconnect On
Auto Reconnect Off
Scanner out of
range
Relink occurs
automatically. If
maximum number of link
attempts is
unsuccessful, then the
scanner must be
relinked by either
pressing the scanner’s
button or placing the
scanner in the base.
(See Maximum Link
Attempts on page 3-24.)
The scanner is
relinked by pressing
the button.
Base reset
(firmware upgrade
or power cycle)
Scanner behaves as if
out of range.
No attempt to relink
made while base is
powered off. Button
must be pressed to
initiate relinking.
Scanner reset due
to firmware
upgrade
Relink occurs automatically.
Scanner reset due
to battery change
Relink occurs automatically.
Scanner placed in
different base unit
Relink to new base occurs automatically.
3 - 23
Maximum Link Attempts
The Maximum Link Attempts setting controls the number of times the scanner tries to form a connection with a base. During the connection setup
process, the scanner transmits in order to search for and connect to a
base. In order to prevent continuous transmissions that could interfere with
other users of the ISM band, the number of attempts to connect is limited
by this setting. After the maximum number of attempts is reached, the
scanner will not attempt to reconnect to a base. Pressing the scanner’s
button or placing the scanner in the cradle resets the attempt count and the
scanner will again try to link.
Scan the Maximum Link Attempts bar code, then scan the number of
attempts for the setting (from 0-255) from the inside back cover. Scan
Save to save the setting. Default = 0.
Maximum Link Attempts
Note: When Auto Reconnect Mode is On, setting Maximum Link Attempts
to zero will cause the scanner to try to link until the Power Time-Out
Timer setting (see page 3-13) expires. When Auto Reconnect Mode
is Off, setting Maximum Link Attempts to zero will cause the scanner
to only attempt linking one time after a trigger pull.
Relink Time-Out
Relink Time-Out controls the idle time between relink attempts. An attempt
to link a scanner to a base typically lasts up to 5 seconds. This is the time
when the scanner is actually attempting a contact . Relink Time-Out controls the amount of time, in seconds, that elapses between the end of one
connection attempt and the start of the next.
Scan the Relink Time-Out bar code, then scan the number of seconds for
the setting (from 1-100) from the inside back cover. Scan Save to save the
setting. Default = 3 seconds.
Relink Time-Out
Bluetooth/ISM Network Activity Examples
Default values
When the scanner goes out of range, the scanner repeatedly attempts to
connect to the base unit. Each attempt consists of approximately 5 seconds of active time followed by 3 seconds of idle time. After one hour, the
scanner powers off and batch mode data is lost.
3 - 24
Maximum Link Attempts set to 15
Other values at default settings
When the scanner goes out of range, 15 attempts are made to link to the
base unit. Each attempt consists of approximately 5 seconds of active time
followed by 3 seconds of idle time. After 15 cycles (8*15 =120), or about 2
minutes, the scanner stops trying to connect to the base, but retains any
bar codes that may have been saved in batch mode. After one hour, the
scanner powers off and batch mode data is lost.
Auto Reconnect Mode set to 0
Maximum Link Attempts set to 15
Other values at default settings
When the scanner goes out of range, no action is taken to relink. When
the scanner’s button is pressed, 15 attempts are made to link to the base.
Each attempt consists of approximately 5 seconds of active time followed
by 3 seconds of idle time. After 15 cycles (8*15 =120), or about 2 minutes,
the scanner stops trying to connect to the base, but retains any bar codes
that may have been saved in batch mode. After one hour, the scanner
powers off and batch mode data is lost. Refer to Auto Reconnect
Mode, page 3-23, to review other events that can start the relink process.
Reset Scanner and Base
After changing settings, you may need to reset your scanner and base. Scan
the Reset Base bar code and wait for the scanner to unlink and relink to a base.
Once that is done, scan the Reset Scanner bar code and wait for the base to
unlink and relink to the scanner.
Reset Scanner
: * : RESE T _ . ³
Reset Base
3 - 25
3 - 26
4
Input/Output Settings
Power Up Beeper
The scanner can be programmed to beep when it’s powered up. Scan the Off
bar code(s) if you don’t want a power up beep. Default = Power Up Beeper On
- Scanner.
Power Up Beeper Off Scanner
* Power Up Beeper On Scanner
Beep on BEL Character
You may wish to force the scanner to beep upon a command sent from the host.
If you scan the following Beep on BEL On bar code, the scanner will beep
every time a BEL character is received from the host. Default = Beep on BEL
Off.
*Beep on BEL Off
Beep on BEL On
4-1
Good Read and Error Indicators
Beeper – Good Read
The beeper may be programmed On or Off in response to a good read.
Turning this option off, only turns off the beeper response to a good read
indication. All error and menu beeps are still audible. Default = Beeper Good Read On.
Beeper - Good Read Off
* Beeper - Good Read On
Beeper Volume – Good Read
The beeper volume codes modify the volume of the beep the scanner
emits on a good read. Default = High.
Low
Medium
* High
Off
4-2
Beeper Pitch – Good Read
The beeper pitch codes modify the pitch (frequency) of the beep the scanner emits on a good read. Default = Medium.
Low (1600 Hz)
* Medium (2350 Hz)
High (4200 Hz)
Beeper - Transmit Order
The beeper transmit order determines when the good read beep occurs.
The scanner can be set to emit the good read beep either before or after
data transmission. Default = Before Transmission.
* Before Transmission
After Transmission
Beeper Pitch – Error
The beeper pitch codes modify the pitch (frequency) of the sound the scanner emits when there is a bad read or error. Default = Razz.
* Razz (100 Hz)
Medium (2000 Hz)
High (4200 Hz)
4-3
Beeper Duration – Good Read
The beeper duration codes modify the length of the beep the scanner emits
on a good read. Default = Normal.
* Normal Beep
Short Beep
Number of Beeps – Good Read
The number of beeps of a good read can be programmed from 1 - 9. The
same number of beeps will be applied to the beeper and LED in response
to a good read. For example, if you program this option to have five beeps,
there will be five beeps and five LED flashes in response to a good read.
The beeps and LED flashes are in sync with one another.
Note: The LEDs can also be programmed separately. See LED
Settings on page 4-6.
To change the number of beeps, scan the following bar code and then scan
a digit (1-9) bar code and the Save bar code on the Programming Chart
inside the back cover of this manual. Default = 1.
Number of Good Read Beeps/LED Flashes
Number of Beeps – Error
The number of beeps and LED flashes emitted by the scanner for a bad
read or error can be programmed from 1 - 9. For example, if you program
this option to have five error beeps, there will be five error beeps and five
LED flashes in response to an error.
Note: The LEDs can also be programmed separately. See LED
Settings on page 4-6.
4-4
To change the number of error beeps, scan the following bar code and then
scan a digit (1-9) bar code and the Save bar code on the Programming
Chart inside the back cover of this manual. Default = 1.
Number of Error Beeps/LED Flashes
4-5
LED Indicators
The green and red LEDs can be programmed to be On or Off and at different
brightness levels to indicate various scanner states. Use the following bar
codes to program the LED indicators.
LED Settings
Default = Red LED On with Laser, Green LED On with Good Scan.
Red LED Off
Green LED Off
Red LED On with Good Scan
* Green LED On with Good Scan
* Red LED On with Laser
Green LED On with Laser
Red LED On when CodeGate
Disabled
Green LED On when CodeGate
Disabled
Red LED On when In-Stand
Green LED On when In-Stand
4-6
Red LED On with CTS
Green LED On with CTS
Red LED On when Battery is Low
Green LED On when Battery is Low
4-7
LED Brightness
Default = Red High, Green High.
Red Off
Green Off
Red Low
Green Low
Red Medium
Green Medium
* Red High
* Green High
In-Stand and Out-Of-Stand Settings
The following settings program the scanner’s behavior when it is either in the
stand, or out of the stand (hand-held).
Caution: When working with In-Stand and Out-of-Stand settings, enable
the settings you want before disabling those you do not want to
use. If you disable settings first, you may program the scanner
so it is unable to read bar codes. if this happens, power cycle
the scanner and scan the defaults bar code on page 1-10.
4-8
In-Stand and Out-of-Stand Defaults
If you want the In-Stand or Out-of-Stand default settings restored to your
scanner, scan the appropriate Defaults bar code below. They reset the
scanner to the custom default settings (see Setting Custom Defaults on
page 1-9). If there are no custom defaults, it will reset the scanner to the
factory default settings. Any settings that have not been specified through
the custom defaults will be defaulted to the factory default settings.
In-Stand Defaults
Out-of-Stand Defaults
Presentation Modes
When the scanner is in the stand, by default, bar codes are automatically
read when they are detected in the scanner’s field of view. When the scanner is out of the stand, by default you must push the button on top of the
scanner to read a bar code. Use the following commands to adjust how the
scanner behaves when it is out of the stand.
Note: If you are using a cordless charge base in Presentation Mode, the
battery will not charge unless the power supply is plugged into the
base’s auxiliary power port.
Presentation Mode Out-of-Stand: When the scanner is not in the stand,
it automatically detects bar codes, then scans and transmits the data. The
laser turns off afterward. (If you are accustomed to a Voyager 9520, this
setting is the same as the 9520’s default.)
Presentation Mode with CodeGate® Out-of-Stand: When the scanner
is not in the stand, it automatically detects bar codes and decodes them.
However, the data is not transmitted until you press the button. The laser
remains on briefly after the transmission. (If you are accustomed to a Voyager 9540, this setting is the same as the 9540’s default.)
Presentation Mode
Out-of-Stand
Presentation Mode with
CodeGate Out-of-Stand
4-9
Manual Activation Mode
In Manual Activation Mode, you must press the button to scan a bar code.
The scanner scans until a bar code is read, or until the button is released.
Default = Manual Activation Mode On In-Stand, Manual Activation On Outof-Stand.
Manual Activation Mode Off
In-Stand
* Manual Activation Mode On
In-Stand
Manual Activation Mode Off
Out-of-Stand
* Manual Activation Mode On
Out-of-Stand
End Manual Activation After Good Read
After a bar code is successfully read, the laser can be programmed either
to remain on and scanning, or to turn off. When End Manual Activation
After Good Read is enabled, the laser turns off and stops scanning after a
good read. If you scan Do Not End Manual Activation After Good Read,
the laser remains on after a good read, but the button must be pressed to
scan the next bar code. Default = End Manual Activation After Good Read.
Do Not End Manual Activation
After Good Read In-Stand
* End Manual Activation After
Good Read In-Stand
Do Not End Manual Activation
After Good Read Out-of-Stand
* End Manual Activation After
Good Read Out-of-Stand
4 - 10
Manual Activation Laser Timeout - Button Settings
You can set a timeout for the length of time the laser remains on and
attempting to decode bar codes when the button is held down, and after it
is released. Set the length (in milliseconds) for a timeout by scanning one
of the following bar codes, then setting the timeout (from 1-65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save.
Default = Button Hold In-Stand 5000 ms, Button Hold Out-of-Stand 5000
ms, Button Release In or Out-of-Stand 0.
Laser Timeout - Button Hold
In-Stand
Laser Timeout - Button
Release In-Stand
Laser Timeout - Button Hold
Out-of-Stand
Laser Timeout - Button
Release Out-of-Stand
4 - 11
CodeGate®
When CodeGate is On, the button is used to allow decoded data to be
transmitted to the host system. The scanner remains on, scanning and
decoding bar codes, but the bar code data is not transmitted until the button is pressed. When CodeGate is Off, bar code data is transmitted when
it is decoded. Default = CodeGate Off in-Stand, CodeGate On Out-ofStand.
* CodeGate Off
In-Stand
CodeGate On
In-Stand
CodeGate Off
Out-of-Stand
* CodeGate On
Out-of-Stand
Object Detection Mode
Object Detection Mode uses an LED to detect when an object is in the
scanner’s field of view. When an object is detected, the laser turns on and
the scanner attempts to scan the bar code. Default = Object Detection
Mode On In-Stand.
Object Detection Mode Off
In-Stand
* Object Detection Mode On
In-Stand
* Object Detection Mode Off
Out-of-Stand
Object Detection Mode On
Out-of-Stand
4 - 12
End Object Detection After Good Read
After a bar code is successfully detected and read from the scanner, the
laser can be programmed either to remain on and scanning, or to turn off.
When End Object Detection After Good Read is enabled, the laser turns
off and stops scanning after a good read. If you scan Do Not End Object
Detection After Good Read, the laser remains on after a good read.
Default = End Object Detection After Good Read.
Do Not End Object Detection
After Good Read In-Stand
* End Object Detection After
Good Read In-Stand
Do Not End Object Detection
After Good Read Out-of-Stand
* End Object Detection After
Good Read Out-of-Stand
Object Detection Laser Timeout
You can set a timeout for the length of time the laser remains on and
attempting to decode bar codes after an object is detected. Set the length
(in milliseconds) for a timeout by scanning the following bar code, then setting the timeout (from 1-65535 milliseconds) by scanning digits from the
Programming Chart, then scanning Save. Default = 5000 ms.
Object Detection Laser
Timeout In-Stand
Object Detection Laser
Timeout Out-of-Stand
4 - 13
Object Detection Distance
When the scanner is in the stand and you are using Object Detection
Mode, you can set the distance range for detecting objects. Short sets the
scanner to detect objects approximately 5 inches (12.7cm) away from the
nose. Long sets it to detect objects approximately 10 inches (25.4cm)
away. Default = Short In-Stand, Long Out-of-Stand.
* Short
In-Stand
Long
In-Stand
Short
Out-of-Stand
* Long
Out-of-Stand
Character Activation Mode
You may use a character sent from the host to trigger the scanner to begin
scanning. When the activation character is received, the scanner continues
scanning until either the Character Activation Laser Timeout (page 4-15), the
deactivation character is received (see Deactivation Character on page 4-16),
or a bar code is transmitted. Scan the following On bar code to use character
activation, then use Activation Character (following) to select the character you
will send from the host to start scanning. Default = Off.
* Off
On
Activation Character
This sets the character used to trigger scanning when using Character
Activation Mode. On the ASCII Conversion Chart (Code Page 1252), page
A-4, find the hex value that represents the character you want to use to
4 - 14
trigger scanning. Scan the following bar code, then use the Programming
Chart to read the alphanumeric combination that represents that ASCII
character. Scan Save to finish.
Activation Character
End Character Activation After Good Read
After a bar code is successfully detected and read from the scanner, the
laser can be programmed either to remain on and scanning, or to turn off.
When End Character Activation After Good Read is enabled, the laser
turns off and stops scanning after a good read. If you scan Do Not End
Character Activation After Good Read, the laser remains on after a good
read. Default = End Character Activation After Good Read.
Do Not End Character Activation
After Good Read
* End Character Activation After
Good Read
Character Activation Laser Timeout
You can set a timeout for the length of time the laser remains on and
attempting to decode bar codes when using Character Activation Mode.
Set the length (in milliseconds) for a timeout by scanning the following bar
code, then setting the timeout (from 1-65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 5000 ms.
Character Activation Laser
Timeout
4 - 15
Character Deactivation Mode
If you have sent a character from the host to trigger the scanner to begin scanning, you can also send a deactivation character to stop scanning. Scan the following On bar code to use character deactivation, then use Deactivation
Character (following) to select the character you will send from the host to terminate scanning. Default = Off.
* Off
On
Deactivation Character
This sets the character used to terminate scanning when using Character
Deactivation Mode. On the ASCII Conversion Chart (Code Page
1252), page A-4, find the hex value that represents the character you want
to use to terminate scanning. Scan the following bar code, then use the
Programming Chart to read the alphanumeric combination that represents
that ASCII character. Scan Save to finish.
Deactivation Character
4 - 16
Reread Delay
This sets the time period before the scanner can read the same bar code a second time. Setting a reread delay protects against accidental rereads of the
same bar code. Longer delays are effective in minimizing accidental rereads.
Use shorter delays in applications where repetitive bar code scanning is
required. Default = Medium.
Short (500 ms)
* Medium (750 ms)
Long (1000 ms)
Extra Long (2000 ms)
User-Specified Reread Delay
If you want to set your own length for the reread delay, scan the following bar
code, then set the delay (from 0-30,000 milliseconds) by scanning digits from
the Programming Chart, then scanning Save.
User-Specified Reread Delay
Output Sequence Overview
Require Output Sequence
When turned off, the bar code data will be output to the host as the scanner
decodes it. When turned on, all output data must conform to an edited
sequence or the scanner will not transmit the output data to the host
device. See Require Output Sequence on page 4-21 for further information.
4 - 17
Output Sequence Editor
This programming selection allows you to program the scanner to output
data (when scanning more than one symbol) in whatever order your application requires, regardless of the order in which the bar codes are
scanned. Reading the Default Sequence symbol programs the scanner to
the following Universal values. These are the defaults. Be certain you
want to delete or clear all formats before you read the Default Sequence
symbol.
Note: If CodeGate is enabled, you must hold the button down while reading
each bar code in a sequence.
Note: To make Output Sequence Editor selections, you’ll need to know the
code I.D., code length, and character match(es) your application
requires. Use the Alphanumeric symbols on the Programming Chart
to read these options.
To Add an Output Sequence
1. Scan the Enter Sequence symbol (see Require Output
Sequence, page 4-21).
2. Code I.D.
On the Symbology Chart on page A-1, find the symbology to which you
want to apply the output sequence format. Locate the Hex value for
that symbology and scan the 2 digit hex value from the Programming
Chart (inside back cover).
3. Length
Specify what length (up to 9999 characters) of data output will be
acceptable for this symbology. Scan the four digit data length from the
Programming Chart. (Note: 50 characters is entered as 0050. 9999 is
a universal number, indicating all lengths.) When calculating the length,
you must count any programmed prefixes, suffixes, or formatted
characters as part of the length (unless using 9999).
4. Character Match Sequences
On the ASCII Conversion Chart (Code Page 1252), page A-4, find the
Hex value that represents the character(s) you want to match. Use the
Programming Chart to read the alphanumeric combination that
represents the ASCII characters. (99 is the Universal number,
indicating all characters.)
5. End Output Sequence Editor
Scan F F to enter an Output Sequence for an additional symbology, or
Save to save your entries.
Other Programming Selections
• Discard
This exits without saving any Output Sequence changes.
4 - 18
Output Sequence Example
In this example, you are scanning Code 93, Code 128, and Code 39 bar
codes, but you want the scanner to output Code 39 1st, Code 128 2nd, and
Code 93 3rd, as shown below.
Note: Code 93 must be enabled to use this example.
A - Code 39
B - Code 128
C - Code 93
You would set up the sequence editor with the following command line:
SEQBLK62999941FF6A999942FF69999943FF
The breakdown of the command line follows:
SEQBLKsequence editor start command
62
code identifier for Code 39
9999
code length that must match for Code 39, 9999 = all lengths
41
start character match for Code 39, 41h = “A”
FF
termination string for first code
6A
code identifier for Code 128
9999
code length that must match for Code 128, 9999 = all lengths
42
start character match for Code 128, 42h = “B”
FF
termination string for second code
69
code identifier for Code 93
9999
code length that must match for Code 93, 9999 = all lengths
43
start character match for Code 93, 43h = “C”
FF
termination string for third code
To program the previous example using specific lengths, you would have to
count any programmed prefixes, suffixes, or formatted characters as part of
the length. If you use the example on page 4-19, but assume a  suffix
and specific code lengths, you would use the following command line:
SEQBLK62001241FF6A001342FF69001243FF
The breakdown of the command line follows:
4 - 19
SEQBLKsequence editor start command
62
code identifier for Code 39
0012
A - Code 39 sample length (11) plus CR suffix (1) = 12
41
start character match for Code 39, 41h = “A”
FF
termination string for first code
6A
code identifier for Code 128
0013
B - Code 128 sample length (12) plus CR suffix (1) = 13
42
start character match for Code 128, 42h = “B”
FF
termination string for second code
69
code identifier for Code 93
0012
C - Code 93 sample length (11) plus CR suffix (1) = 12
43
start character match for Code 93, 43h = “C”
FF
termination string for third code
Output Sequence Editor
Enter Sequence
Default Sequence
Sequence Timeout
You may wish to set the maximum time between bar code scans in an output sequence. If that maximum time is not met, the output sequence operation is terminated. Set the length (in milliseconds) for a timeout by
scanning the following bar code, then setting the timeout (from 1-65535
milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 5000 msec.
Sequence Timeout
4 - 20
Sequence Match Beeper
By default, the scanner beeps when a sequence match is found. If you
want the scanner to remain silent, scan the following Sequence Match
Beeper Off bar code. Default = Sequence Match Beeper On.
Sequence Match Beeper Off
* Sequence Match Beeper On
Partial Sequence
If an output sequence operation is terminated before all your output
sequence criteria are met, the bar code data acquired to that point is a
“partial sequence.”
Scan Discard Partial Sequence to discard partial sequences when the
output sequence operation is terminated before completion.
Scan Transmit Partial Sequence to transmit partial sequences. (Any
fields in the sequence where no data match occurred will be skipped in the
output.) If you have programmed a Sequence Timeout (page 4-20) and
the timeout is reached, the partial sequence is transmitted. Default = Discard Partial Sequence.
Transmit Partial Sequence
* Discard Partial Sequence
Require Output Sequence
When an output sequence is Required, all output data must conform to an
edited sequence or the scanner will not transmit the output data to the host
device. When it’s On/Not Required, the scanner will attempt to get the
output data to conform to an edited sequence but, if it cannot, the scanner
transmits all output data to the host device as is.
4 - 21
When the output sequence is Off, the bar code data is output to the host as
the scanner decodes it. Default = Off.
Required
On/Not Required
*Off
No Read
With No Read turned On, the scanner notifies you if a code cannot be read. If
using an EZConfig-Scanning Tool Scan Data Window (see page 9-2), an “NR”
appears when a code cannot be read. If No Read is turned Off, the “NR” will
not appear. Default = Off.
On
* Off
If you want a different notation than “NR,” for example, “Error,” or “Bad Code,”
you can edit the output message (see Data Formatting beginning on page 6-1).
The hex code for the No Read symbol is 9C.
4 - 22
5
Data Editing
Prefix/Suffix Overview
When a bar code is scanned, additional information is sent to the host computer
along with the bar code data. This group of bar code data and additional,
user-defined data is called a “message string.” The selections in this section
are used to build the user-defined data into the message string.
Prefix and Suffix characters are data characters that can be sent before and
after scanned data. You can specify if they should be sent with all symbologies,
or only with specific symbologies. The following illustration shows the breakdown of a message string:
Prefix
Scanned Data
1-11
variable length
alpha numeric &
control characters
Suffix
1-11
alpha numeric &
control characters
Points to Keep In Mind
• It is not necessary to build a message string. The selections in this
chapter are only used if you wish to alter the default settings. Default
prefix = None. Default suffix is dependent on interface.
• A prefix or suffix may be added or cleared from one symbology or all
symbologies.
• You can add any prefix or suffix from the ASCII Conversion Chart (Code
Page 1252), beginning on page A-4, plus Code I.D. and AIM I.D.
• You can string together several entries for several symbologies at one
time.
• Enter prefixes and suffixes in the order in which you want them to appear
on the output.
• When setting up for specific symbologies (as opposed to all
symbologies), the specific symbology ID value counts as an added prefix
or suffix character.
• The maximum size of a prefix or suffix configuration is 32 characters,
which includes header information.
To Add a Prefix or Suffix:
Step 1. Scan the Add Prefix or Add Suffix symbol (page 5-3).
Step 2. Determine the 2 digit Hex value from the Symbology Chart
(included in the Symbology Chart, beginning on page A-1) for the
5-1
symbology to which you want to apply the prefix or suffix. For
example, for Code 128, Code ID is “j” and Hex ID is “6A”.
Step 3. Scan the 2 hex digits from the Programming Chart inside the back
cover of this manual or scan 9, 9 for all symbologies.
Step 4. Determine the hex value from the ASCII Conversion Chart (Code
Page 1252) on page A-4, for the prefix or suffix you wish to enter.
Step 5. Scan the 2 digit hex value from the Programming Chart inside the
back cover of this manual.
Step 6. Repeat Steps 4 and 5 for every prefix or suffix character.
Step 7. To add the Code I.D., scan 5, C, 8, 0.
To add AIM I.D., scan 5, C, 8, 1.
To add a backslash (\), scan 5, C, 5, C.
Note: To add a backslash (\) as in Step 7, you must scan 5C twice – once
to create the leading backslash and then to create the backslash
itself.
Step 8. Scan Save to exit and save, or scan Discard to exit without saving.
Repeat Steps 1-6 to add a prefix or suffix for another symbology.
Example: Add a Suffix to a specific symbology
To send a CR (carriage return)Suffix for U.P.C. only:
Step 1. Scan Add Suffix.
Step 2. Determine the 2 digit hex value from the Symbology Chart
(included in the Symbology Chart, beginning on page A-1) for
U.P.C.
Step 3. Scan 6, 3 from the Programming Chart inside the back cover of this
manual.
Step 4. Determine the hex value from the ASCII Conversion Chart (Code
Page 1252) on page A-4, for the CR (carriage return).
Step 5. Scan 0, D from the Programming Chart inside the back cover of this
manual.
Step 6. Scan Save, or scan Discard to exit without saving.
To Clear One or All Prefixes or Suffixes
You can clear a single prefix or suffix, or clear all prefixes/suffixes for a
symbology. If you have been entering prefixes and suffixes for single symbologies, you can use Clear One Prefix (Suffix) to delete a specific character from a symbology. When you Clear All Prefixes (Suffixes), all the
prefixes or suffixes for a symbology are deleted.
5-2
Step 1. Scan the Clear One Prefix or Clear One Suffix symbol.
Step 2. Determine the 2 digit Hex value from the Symbology Chart
(included in the Symbology Chart, beginning on page A-1) for the
symbology from which you want to clear the prefix or suffix.
Step 3. Scan the 2 digit hex value from the Programming Chart inside the
back cover of this manual or scan 9, 9 for all symbologies.
Your change is automatically saved.
To Add a Carriage Return Suffix to All Symbologies
Scan the following bar code if you wish to add a carriage return suffix to all
symbologies at once. This action first clears all current suffixes, then programs a carriage return suffix for all symbologies.
Add CR Suffix
All Symbologies
Prefix Selections
Add Prefix
Clear One Prefix
Clear All Prefixes
5-3
Suffix Selections
Add Suffix
Clear One Suffix
Clear All Suffixes
Transmit Alternate Extended ASCII Characters
You may need to emulate special keyboard functions, such as up or down
arrows, Alt/Make or Alt/Break commands, that are not supported in the
Extended ASCII Character table. Refer to Alternate Extended ASCII
Characters (page 5-5) for a range of keyboard function keys and corresponding
decimal and hex characters. If you scan the Transmit Alternate Extended
ASCII code, any hex entries in a prefix or suffix will result in the corresponding
Keyboard Function output.
Example: Transmit Alternate Extended ASCII is enabled, and you scan Add
Suffix, then scan 9 9 8 9. All symbologies (99) would have a suffix
of a Page Down (hex 89) added to them.
When Transmit Normal Extended ASCII is selected, the normal extended
ASCII character is transmitted (see ASCII Conversion Chart (Code Page 1252)
on page A-4).
Example: Transmit Normal Extended ASCII is enabled, and you scan Add
Suffix, then scan 9 9 8 9. All symbologies (99) would have a suffix
of a ‰ character added to them.
Default = Transmit Alternate Extended ASCII.
* Transmit Alternate Extended
ASCII
Transmit Normal Extended
ASCII
5-4
Alternate Extended ASCII Characters
DEC HEX Keyboard Function
128 80
129 81
130 82
up arrow ↑
down arrow ↓
right arrow →
DEC HEX Keyboard Function
152 98
F9
153 99
F10
154 9A
F11
131 83
left arrow ←
155 9B
F12
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
Insert
Delete
Home
End
Page Up
Page Down
Right ALT
Right CTRL
Reserved
Reserved
Numeric Keypad Enter
Numeric Keypad /
F1
F2
F3
F4
F5
F6
F7
F8
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
Numeric Keypad +
Numeric Keypad Numeric Keypad *
Caps Lock
Num Lock
Left Alt
Left Ctrl
Left Shift
Right Shift
Print Screen
Tab
Shift Tab
Enter
Esc
Alt Make
Alt Break
Control Make
Control Break
Alt Sequence with 1 Character
Ctrl Sequence with 1 Character
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
5-5
Function Code Transmit
When this selection is enabled and function codes are contained within the
scanned data, the scanner transmits the function code to the terminal. Charts
of these function codes are provided in Supported Interface Keys starting on
page 8-2. When the scanner is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted. Default = Enable.
* Enable
Disable
Communication Check Character
To enhance security, you can specify the transmission type of a check character; either LRC where the calculation starts on the first transmitted character,
LRC where the calculation starts on the second transmitted character, or CRC.
Note: This option adds a check character to the bar code data for all
symbologies. If you need to enable or disable check characters for
individual symbologies, see Symbologies beginning on page 7-1.
Scan the following bar code to set the communication check character type.
Default = None.
* None
LRC Starts on 1st Character
LRC Starts on 2nd Character
CRC
5-6
Intercharacter, Interfunction, and
Intermessage Delays
Some terminals drop information (characters) if data comes through too quickly.
Intercharacter, interfunction, and intermessage delays slow the transmission of
data, increasing data integrity.
Intercharacter Delay
An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may
be placed between the transmission of each character of scanned data.
Scan the following Intercharacter Delay bar code, then scan the number
of 5ms delays, and the Save bar code using the Programming Chart inside
the back cover of this manual.
Prefix
Scanned Data
Suffix
Intercharacter Delay
Intercharacter Delay
To remove this delay, scan the Intercharacter Delay bar code, then set the
number of delays to 0. Scan the Save bar code using the Programming
Chart inside the back cover of this manual.
Note: Intercharacter delays are not supported in USB serial emulation.
User Specified Intercharacter Delay
An intercharacter delay of up to 5000 milliseconds (in 5ms increments)
may be placed after the transmission of a particular character of scanned
data. Scan the following Delay Length bar code, then scan the number of
5ms delays, and the Save bar code using the Programming Chart inside
the back cover of this manual.
5-7
Next, scan the Character to Trigger Delay bar code, then the 2-digit hex
value for the ASCII character that will trigger the delay ASCII Conversion
Chart (Code Page 1252) on page A-4.
Delay Length
Character to Trigger Delay
To remove this delay, scan the Delay Length bar code, and set the number
of delays to 0. Scan the Save bar code using the Programming Chart
inside the back cover of this manual.
Interfunction Delay
An interfunction delay of up to 5000 milliseconds (in 5ms increments) may
be placed between the transmission of each segment of the message
string. Scan the following Interfunction Delay bar code, then scan the
number of 5ms delays, and the Save bar code using the Programming
Chart inside the back cover of this manual.
Prefix
STX
Scanned Data
HT
2 3 4 5
Suffix
CR
LF
Interfunction Delays
Interfunction Delay
To remove this delay, scan the Interfunction Delay bar code, then set the
number of delays to 0. Scan the Save bar code using the Programming
Chart inside the back cover of this manual.
5-8
Intermessage Delay
An intermessage delay of up to 5000 milliseconds (in 5ms increments)
may be placed between each scan transmission. Scan the following Intermessage Delay bar code, then scan the number of 5ms delays, and the
Save bar code using the Programming Chart inside the back cover of this
manual.
1st Scan Transmission
2nd Scan Transmission
Intermessage Delay
Intermessage Delay
To remove this delay, scan the Intermessage Delay bar code, then set the
number of delays to 0. Scan the Save bar code using the Programming
Chart inside the back cover of this manual.
5-9
5 - 10
6
Data Formatting
Data Format Editor Introduction
You may use the Data Format Editor to change the scanner’s output. For example, you can use the Data Format Editor to insert characters at certain points in
bar code data as it is scanned. The selections in the following pages are used
only if you wish to alter the output. Default Data Format setting = None.
Normally, when you scan a bar code, it gets outputted automatically; however
when you create a format, you must use a “send” command (see Send
Commands on page 6-4) within the format program to output data.
Multiple formats may be programmed into the scanner. They are stacked in the
order in which they are entered. However, the following list presents the order
in which formats are applied:
1.
2.
3.
4.
5.
6.
7.
8.
Specific Terminal ID, Actual Code ID, Actual Length
Specific Terminal ID, Actual Code ID, Universal Length
Specific Terminal ID, Universal Code ID, Actual Length
Specific Terminal ID, Universal Code ID, Universal Length
Universal Terminal ID, Actual Code ID, Actual Length
Universal Terminal ID, Actual Code ID, Universal Length
Universal Terminal ID, Universal Code ID, Actual Length
Universal Terminal ID, Universal Code ID, Universal Length
The maximum size of a data format configuration is 256 bytes, which includes
header information. No format can contain more than 50 bytes.
If you have changed data format settings, and wish to clear all formats and
return to the factory defaults, scan the following Default Data Format code.
* Default Data Format
To Add a Data Format
Step 1. Scan the Enter Data Format symbol (page 6-2).
Step 2. Select Primary/Alternate Format
Determine if this will be your primary data format, or one of 3 alternate
formats. This allows you to save a total of 4 different data formats. To
program your primary format, scan 0 using the Programming Chart
inside the back cover of this manual. If you are programming an
alternate format, scan 1, 2, or 3, depending on which alternate format
6-1
you are programming. (See Primary/Alternate Data Formats on page
6-10 for further information.)
Step 3. Terminal Type
Refer to Terminal ID Table (page 6-4) and locate the Terminal ID
number for your PC. Scan three numeric bar codes on the
Programming Chart to program the scanner for your terminal ID (you
must enter 3 digits). For example, scan 0 0 3 for an AT wedge.
Note: The wildcard for all terminal types is 099.
Step 4. Code I.D.
In the Symbology Chart, beginning on page A-1, find the symbology to
which you want to apply the data format. Locate the Hex value for that
symbology and scan the 2 digit hex value from the Programming Chart
inside the back cover of this manual.
Step 5. Length
Specify what length (up to 9999 characters) of data will be acceptable
for this symbology. Scan the four digit data length from the
Programming Chart inside the back cover of this manual. (Note: 50
characters is entered as 0050. 9999 is a universal number, indicating
all lengths.)
Step 6. Editor Commands
Refer to (page 6-4). Scan the symbols that represent the command you
want to enter. 94 alphanumeric characters may be entered for each
symbology data format.
Step 7. Scan Save to save your data format, or Discard to exit without saving
your changes.
Enter Data Format
Save
Discard
6-2
Other Programming Selections
Clear One Data Format
This deletes one data format for one symbology. If you are clearing the
primary format, scan 0 from the Programming Chart inside the back
cover of this manual. If you are clearing an alternate format, scan 1, 2,
or 3, depending on the format you are clearing. Scan the Terminal Type
and Code I.D. (see Symbology Chart on page A-1), and the bar code
data length for the specific data format that you want to delete. All other
formats remain unaffected.
Clear all Data Formats
This clears all data formats.
Save to exit and save your data format changes.
Discard to exit without saving any data format changes.
Clear One Data Format
Clear All Data Formats
Save
Discard
6-3
Terminal ID Table
Terminal
Model(s)
IBM
PC/AT and compatibles
PS2 Keyboard
USB SurePOS Handheld
Scanner
USB SurePOS Tabletop
Scanner
True
TTL
RS232
RS485
USB
Serial
PC Keyboard
Mac Keyboard
Japanese Keyboard (PC)
HID POS
Terminal
ID
003
002
128
129
000
000
051
130
124
125
134
131
Data Format Editor Commands
Send Commands
Send all characters
F1 Include in the output message all of the characters from the input
message, starting from current cursor position, followed by an insert
character. Syntax = F1xx where xx stands for the insert character’s hex
value for its ASCII code.
Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4
for decimal, hex and character codes.
Send a number of characters
F2 Include in the output message a number of characters followed by an
insert character. Start from the current cursor position and continue for
“nn” characters or through the last character in the input message,
followed by character “xx.” Syntax = F2nnxx where nn stands for the
numeric value (00-99) for the number of characters, and xx stands for
the insert character’s hex value for its ASCII code.
Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4
for decimal, hex and character codes.
6-4
Send all characters up to a particular character
F3 Include in the output message all characters from the input message,
starting with the character at the current cursor position and continuing
to, but not including, the search character “ss,” followed by an insert
character. The cursor is moved forward to the “ss” character. Syntax
= F3ssxx where ss stands for the search character’s hex value for its
ASCII code, and xx stands for the insert character’s hex value for its
ASCII code.
Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4 for
decimal, hex and character codes.
Send all but the last characters
E9 Include in the output message all but the last “nn” characters, starting
from the current cursor position. The cursor is moved forward to one
position past the last input message character included. Syntax = E9nn
where nn stands for the numeric value (00-99) for the number of
characters that will not be sent at the end of the message.
Insert a character multiple times
F4 Send “xx” character “nn” times in the output message, leaving the
cursor in the current position. Syntax = F4xxnn where xx stands for the
insert character’s hex value for its ASCII code, and nn is the numeric
value (00-99) for the number of times it should be sent.
Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4 for
decimal, hex and character codes.
Insert symbology name
B3 Insert the name of the bar code’s symbology in the output message,
without moving the cursor. Only symbologies with a Honeywell ID are
included (see Symbology Chart on page A-1).
Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4 for
decimal, hex and character codes.
Insert bar code length
B4 Insert the bar code’s length in the output message, without moving the
cursor. The length is expressed as a numeric string and does not
include leading zeroes.
Move Commands
Move the cursor forward a number of characters
F5 Move the cursor ahead “nn” characters from current cursor position.
Syntax = F5nn where nn is the numeric value (00-99) for the number
of characters the cursor should be moved ahead.
Move the cursor backward a number of characters
F6 Move the cursor back “nn” characters from current cursor position.
Syntax = F6nn where nn is the numeric value (00-99) for the number
of characters the cursor should be moved back.
6-5
Move the cursor to the beginning
F7 Move the cursor to the first character in the input message. Syntax =
F7.
Move the cursor to the end
EA Move the cursor to the last character in the input message. Syntax =
EA.
Search Commands
Search forward for a character
F8 Search the input message forward for “xx” character from the current
cursor position, leaving the cursor pointing to the “xx” character.
Syntax = F8xx where xx stands for the search character’s hex value for
its ASCII code.
Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4
for decimal, hex and character codes.
Search backward for a character
F9 Search the input message backward for “xx” character from the current
cursor position, leaving the cursor pointing to the “xx” character.
Syntax = F9xx where xx stands for the search character’s hex value for
its ASCII code.
Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4
for decimal, hex and character codes.
Search forward for a string
B0 Search forward for “s” string from the current cursor position, leaving
cursor pointing to “s” string. Syntax = B0nnnnS where nnnn is the string
length (up to 9999), and S consists of the ASCII hex value of each
character in the match string. For example, B0000454657374 will
search forward for the first occurrence of the 4 character string “Test.”
Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4
for decimal, hex and character codes.
Search backward for a string
B1 Search backward for “s” string from the current cursor position, leaving
cursor pointing to “s” string. Syntax = B1nnnnS where nnnn is the string
length (up to 9999), and S consists of the ASCII hex value of each
character in the match string. For example, B1000454657374 will
search backward for the first occurrence of the 4 character string “Test.”
Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4
for decimal, hex and character codes.
6-6
Search forward for a non-matching character
E6 Search the input message forward for the first non-“xx” character from
the current cursor position, leaving the cursor pointing to the non-“xx”
character. Syntax = E6xx where xx stands for the search character’s
hex value for its ASCII code.
Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4 for
decimal, hex and character codes.
Search backward for a non-matching character
E7 Search the input message backward for the first non-“xx” character
from the current cursor position, leaving the cursor pointing to the non“xx” character. Syntax = E7xx where xx stands for the search
character’s hex value for its ASCII code.
Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4 for
decimal, hex and character codes.
Miscellaneous Commands
Suppress characters
FB Suppress all occurrences of up to 15 different characters, starting at the
current cursor position, as the cursor is advanced by other commands.
When the FC command is encountered, the suppress function is
terminated. The cursor is not moved by the FB command.
Syntax = FBnnxxyy . .zz where nn is a count of the number of
suppressed characters in the list, and xxyy .. zz is the list of characters
to be suppressed.
Stop suppressing characters
FC Disables suppress filter and clear all suppressed characters. Syntax =
FC.
Replace characters
E4 Replaces up to 15 characters in the output message, without moving
the cursor. Replacement continues until the E5 command is
encountered. Syntax = E4nnxx1xx2yy1yy2...zz1zz2 where nn is the total
count of the number of characters in the list (characters to be replaced
plus replacement characters); xx1 defines characters to be replaced
and xx2 defines replacement characters, continuing through zz1 and
zz2.
Stop replacing characters
E5 Terminates character replacement. Syntax = E5.
6-7
Compare characters
FE Compare the character in the current cursor position to the character
“xx.” If characters are equal, move the cursor forward one position.
Syntax = FExx where xx stands for the comparison character’s hex
value for its ASCII code.
Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4
for decimal, hex and character codes.
Compare string
B2 Compare the string in the input message to the string “s.” If the strings
are equal, move the cursor forward past the end of the string. Syntax
= B2nnnnS where nnnn is the string length (up to 9999), and S consists
of the ASCII hex value of each character in the match string. For
example, B2000454657374 will compare the string at the current
cursor position with the 4 character string “Test.”
Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4
for decimal, hex and character codes.
Check for a number
EC Check to make sure there is an ASCII number at the current cursor
position. The format is aborted if the character is not numeric.
Check for non-numeric character
ED Check to make sure there is a non-numeric ASCII character at the
current cursor position. The format is aborted if the character is
numeric.
Insert a delay
EF Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting
from the current cursor position. Syntax = EFnnnn where nnnn stands
for the delay in 5ms increments, up to 9999. This command can only
be used with keyboard wedge interfaces.
Data Formatter
When Data Formatter is turned Off, the bar code data is output to the host as
read, including prefixes and suffixes.
Data Formatter Off
You may wish to require the data to conform to a data format you have created
and saved. The following settings can be applied to your data format:
Data Formatter On, Not Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and
suffixes are transmitted.
6-8
Data Formatter On, Not Required, Drop Prefix/Suffix
Scanned data is modified according to your data format. If a data format is
found for a particular symbol, those prefixes and suffixes are not
transmitted.
Data Format Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and
suffixes are transmitted. Any data that does not match your data format
requirements generates an error tone and the data in that bar code is not
transmitted. If you wish to process this type of bar code without generating
an error tone, see Data Format Non-Match Error Tone.
Data Format Required, Drop Prefix/Suffix
Scanned data is modified according to your data format. If a data format is
found for a particular symbol, those prefixes and suffixes are not
transmitted. Any data that does not match your data format requirements
generates an error tone. If you wish to process this type of bar code without
generating an error tone, see Data Format Non-Match Error Tone.
Choose one of the following options. Default = Data Formatter On, Not
Required, Keep Prefix/Suffix.
* Data Formatter On,
Not Required,
Keep Prefix/Suffix
Data Formatter On,
Not Required,
Drop Prefix/Suffix
Data Format Required,
Keep Prefix/Suffix
Data Format Required,
Drop Prefix/Suffix
Data Format Non-Match Error Tone
When a bar code is encountered that doesn’t match your required data format, the scanner normally generates an error tone. However, you may
want to continue scanning bar codes without hearing the error tone. If you
scan the Data Format Non-Match Error Tone Off bar code, data that
doesn’t conform to your data format is not transmitted, and no error tone
6-9
will sound. If you wish to hear the error tone when a non-matching bar
code is found, scan the Data Format Non-Match Error Tone On bar code.
Default = Data Format Non-Match Error Tone On.
* Data Format Non-Match Error
Tone On
Data Format Non-Match
Error Tone Off
Primary/Alternate Data Formats
You can save up to four data formats, and switch between these formats. Your
primary data format is saved under 0. Your other three formats are saved under
1, 2, and 3. To set your device to use one of these formats, scan one of the following bar codes.
Primary Data Format
Data Format 1
Data Format 2
Data Format 3
Single Scan Data Format Change
You can also switch between data formats for a single scan. The next bar
code is scanned using an alternate data format, then reverts to the format
you have selected above (either Primary, 1, 2, or 3).
6 - 10
For example, you may have set your device to the data format you saved as
Data Format 3. You can switch to Data Format 1 for a single button press
by scanning the following Single Scan-Data Format 1 bar code. The next
bar code that is scanned uses Data Format 1, then reverts back to Data
Format 3.
Single Scan-Primary
Data Format
Single Scan-Data Format 1
Single Scan-Data Format 2
Single Scan-Data Format 3
6 - 11
6 - 12
7
Symbologies
This programming section contains the following menu selections. Refer to
Chapter 10 for settings and defaults.
• All Symbologies
• GS1-128
• Airline Code 5 - see Straight 2 of 5
IATA (two-bar start/stop)
• Interleaved 2 of 5
• China Post (Hong Kong 2 of 5)
• ISBT 128
• Codabar
• Matrix 2 of 5
• Code 11
• MSI
• Code 128
• NEC 2 of 5
• Code 32 Pharmaceutical (PARAF)
• Plessey Code
• Code 39
• Postal Codes
• Code 93
• Straight 2 of 5 IATA (two-bar start/
stop)
• EAN/JAN-13
• Straight 2 of 5 Industrial (three-bar
start/stop)
• EAN/JAN-8
• Telepen
• GS1 DataBar Expanded
• Trioptic Code
• GS1 DataBar Limited
• UPC-A
• GS1 DataBar Omnidirectional
• UPC-A/EAN-13 with Extended
Coupon Code
• GS1 Emulation
• UPC-E0
All Symbologies
If you want to decode all the symbologies allowable for your scanner, scan the
All Symbologies On code. If on the other hand, you want to decode only a
particular symbology, scan All Symbologies Off followed by the On symbol for
that particular symbology.
All Symbologies On
All Symbologies Off
7-1
Message Length Description
You are able to set the valid reading length of some of the bar code symbologies. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will issue an error tone. You may wish to set the same
value for minimum and maximum length to force the scanner to read fixed
length bar code data. This helps reduce the chances of a misread.
EXAMPLE:
Decode only those bar codes with a count of 9-20 characters.
Min. length = 09Max. length = 20
EXAMPLE:
Decode only those bar codes with a count of 15 characters.
Min. length = 15Max. length = 15
For a value other than the minimum and maximum message length defaults,
scan the bar codes included in the explanation of the symbology, then scan the
digit value of the message length and Save bar codes on the Programming
Chart inside the back cover of this manual. The minimum and maximum
lengths and the defaults are included with the respective symbologies.
7-2
Codabar

Codabar On/Off
* On
Off
Codabar Start/Stop Characters
Start/Stop characters identify the leading and trailing ends of the bar code.
You may either transmit, or not transmit Start/Stop characters.
Default = Don’t Transmit.
Transmit
* Don’t Transmit
Codabar Check Character
Codabar check characters are created using different “modulos.” You can
program the scanner to read only Codabar bar codes with Modulo 16, Modulo 7 CD, or CLSI check characters. Default = No Check Character.
No Check Character indicates that the scanner reads and transmits bar
code data with or without a check character.
When Check Character is set to Validate and Transmit, the scanner will
only read Codabar bar codes printed with a check character, and will transmit this character at the end of the scanned data.
7-3
When Check Character is set to Validate, but Don’t Transmit, the unit will
only read Codabar bar codes printed with a check character, but will not
transmit the check character with the scanned data.
* No Check Character
Validate Modulo 16, but
Don’t Transmit
Validate Modulo 16
and Transmit
Validate Modulo 7 CD, but Don’t
Transmit
Validate Modulo 7 CD and
Transmit
Validate CLSI, but Don’t
Transmit
Validate CLSI and Transmit
Codabar Concatenation
Codabar supports symbol concatenation. When you enable concatenation, the scanner looks for a Codabar symbol having a “D” start character,
adjacent to a symbol having a “D” stop character. In this case the two messages are concatenated into one with the “D” characters omitted.
A 1 2 3 4 D
7-4
D 5 6 7 8 A
Select Require to prevent the scanner from decoding a single “D” Codabar
symbol without its companion. This selection has no effect on Codabar
symbols without Stop/Start D characters.
On
* Off
Require
Concatenation Timeout
When searching for bar codes during concatenation, you may wish to
set a delay used to find the next bar code. Set the length (in milliseconds) for this delay by scanning the following bar code, then setting the
timeout (from 1-65535 milliseconds) by scanning digits from the
Programming Chart, then scanning Save. Default = 750.
Concatenation Timeout
Codabar Redundancy
If you are encountering errors when reading Codabar bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the following Codabar Redundancy bar code, then scan a redundancy count
between 0 and 10 on the Programming Chart inside the back cover of this
manual. Then scan the Save bar code. Default = 0.
Codabar Redundancy
7-5
Codabar Message Length
Scan the following bar codes to change the message length. Refer to
Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
7-6
Code 39
< Default All Code 39 Settings >
Code 39 On/Off
* On
Off
Code 39 Start/Stop Characters
Start/Stop characters identify the leading and trailing ends of the bar code.
You may either transmit, or not transmit Start/Stop characters. Default =
Don’t Transmit.
Transmit
* Don’t Transmit
Code 39 Check Character
No Check Character indicates that the scanner reads and transmits bar
code data with or without a check character.
When Check Character is set to Validate, but Don’t Transmit, the unit
only reads Code 39 bar codes printed with a check character, but will not
transmit the check character with the scanned data.
7-7
When Check Character is set to Validate and Transmit, the scanner only
reads Code 39 bar codes printed with a check character, and will transmit
this character at the end of the scanned data. Default = No Check Character.
* No Check Character
Validate, but Don’t Transmit
Validate and Transmit
Code 39 Redundancy
If you are encountering errors when reading Code 39 bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the Code
39 Redundancy bar code below, then scan a redundancy count between 0
and 10 on the Programming Chart inside the back cover of this manual.
Then scan the Save bar code. Default = 0.
Code 39 Redundancy
Code 39 Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
7-8
Code 32 Pharmaceutical (PARAF)
Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies. This symbology is also known as PARAF.
On
* Off
Full ASCII
If Full ASCII Code 39 decoding is enabled, certain character pairs within
the bar code symbol will be interpreted as a single character. For example:
$V will be decoded as the ASCII character SYN, and /C will be decoded as
the ASCII character #. Default = Off.
NUL %U
DLE $P
SP
SPACE 0
%V
‘
%W p
+P
SOH $A
DC1 $Q
/A
+A
+Q
STX $B
DC2 $R
“
/B
+B
+R
ETX $C
DC3 $S
/C
+C
+S
EOT $D
DC4 $T
/D
+D
+T
ENQ $E
NAK $U
/E
+E
+U
ACK $F
SYN $V
/F
+F
+V
BEL $G
ETB $W
‘
/G
+G
+W
BS
$H
CAN $X
/H
+H
+X
HT
$I
EM
$Y
/I
+I
+Y
LF
$J
SUB $Z
/J
/Z
+J
+Z
VT
$K
ESC %A
/K
%F
%K
+K
%P
FF
$L
FS
%B
/L
%G L
%L
+L
%Q
CR
$M
GS
%C
%H
%M m
+M
%R
SO
$N
RS
%D
%I
%N
+N
%S
SI
$O
US
%E
/O
%J
%O o
+O
DEL %T
7-9
Character pairs /M and /N decode as a minus sign and period respectively.
Character pairs /P through /Y decode as 0 through 9.
Full ASCII On
* Full ASCII Off
7 - 10
Interleaved 2 of 5
< Default All Interleaved 2 of 5 Settings >
Interleaved 2 of 5 On/Off
* On
Off
Follett Formatting
* Off
On
NULL Characters
Interleaved 2 of 5 requires an even number of characters. When an odd
number of characters is present, it is due to NULL characters embedded in
the bar code. Scan the On bar code below to decode this type of Interleaved 2 of 5 bar code. Default = Off.
* Off
On
7 - 11
Check Digit
No Check Digit indicates that the scanner reads and transmits bar code
data with or without a check digit.
When Check Digit is set to Validate, but Don’t Transmit, the unit only
reads Interleaved 2 of 5 bar codes printed with a check digit, but will not
transmit the check digit with the scanned data.
When Check Digit is set to Validate and Transmit, the scanner only reads
Interleaved 2 of 5 bar codes printed with a check digit, and will transmit this
digit at the end of the scanned data. Default = No Check Digit.
* No Check Digit
Validate, but Don’t Transmit
Validate and Transmit
Interleaved 2 of 5 Redundancy
If you are encountering errors when reading Interleaved 2 of 5 bar codes,
you may want to adjust the redundancy count. Redundancy adjusts the
number of times a bar code is decoded before transmission, which may
reduce the number of errors. Note that the higher the redundancy count,
the longer it will take to decode the bar code. To adjust the redundancy,
scan the Interleaved 2 of 5 Redundancy bar code below, then scan a
redundancy count between 0 and 10 on the Programming Chart inside the
back cover of this manual. Then scan the Save bar code. Default = 0.
Interleaved 2 of 5 Redundancy
7 - 12
Interleaved 2 of 5 Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 6, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
NEC 2 of 5
< Default All NEC 2 of 5 Settings >
NEC 2 of 5 On/Off
On
* Off
Check Digit
No Check Digit indicates that the scanner reads and transmits bar code
data with or without a check digit.
When Check Digit is set to Validate, but Don’t Transmit, the unit only
reads NEC 2 of 5 bar codes printed with a check digit, but will not transmit
the check digit with the scanned data.
7 - 13
When Check Digit is set to Validate and Transmit, the scanner only reads
NEC 2 of 5 bar codes printed with a check digit, and will transmit this digit
at the end of the scanned data. Default = No Check Digit.
* No Check Digit
Validate, but Don’t Transmit
Validate and Transmit
NEC 2 of 5 Redundancy
If you are encountering errors when reading NEC 2 of 5 bar codes, you
may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce
the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the
NEC 2 of 5 Redundancy bar code below, then scan a redundancy count
between 0 and 10 on the Programming Chart inside the back cover of this
manual. Then scan the Save bar code. Default = 0.
NEC 2 of 5 Redundancy
NEC 2 of 5 Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
7 - 14
Code 93
< Default All Code 93 Settings >
Code 93 On/Off
* On
Off
Code 93 Redundancy
If you are encountering errors when reading Code 93 bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the Code
93 Redundancy bar code below, then scan a redundancy count between 0
and 10 on the Programming Chart inside the back cover of this manual.
Then scan the Save bar code. Default = 0.
Code 93 Redundancy
7 - 15
Code 93 Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
Straight 2 of 5 Industrial (three-bar start/stop)

Straight 2 of 5 Industrial On/Off
On
* Off
Straight 2 of 5 Industrial Redundancy
If you are encountering errors when reading Straight 2 of 5 Industrial bar
codes, you may want to adjust the redundancy count. Redundancy adjusts
the number of times a bar code is decoded before transmission, which may
reduce the number of errors. Note that the higher the redundancy count,
the longer it will take to decode the bar code. To adjust the redundancy,
scan the Straight 2 of 5 Industrial Redundancy bar code below, then
7 - 16
scan a redundancy count between 0 and 10 on the Programming Chart
inside the back cover of this manual. Then scan the Save bar code.
Default = 0.
Straight 2 of 5 Industrial
Redundancy
Straight 2 of 5 Industrial Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 3-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
7 - 17
Straight 2 of 5 IATA (two-bar start/stop)
Note: This symbology is also known as Airline Code 5.

Straight 2 of 5 IATA On/Off
On
* Off
Straight 2 of 5 IATA Redundancy
If you are encountering errors when reading Straight 2 of 5 IATA bar codes,
you may want to adjust the redundancy count. Redundancy adjusts the
number of times a bar code is decoded before transmission, which may
reduce the number of errors. Note that the higher the redundancy count,
the longer it will take to decode the bar code. To adjust the redundancy,
scan the Straight 2 of 5 IATA Redundancy bar code below, then scan a
redundancy count between 0 and 10 on the Programming Chart inside the
back cover of this manual. Then scan the Save bar code. Default = 0.
Straight 2 of 5 IATA
Redundancy
7 - 18
Straight 2 of 5 IATA Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 13, Maximum
Default = 15.
Minimum Message Length
Maximum Message Length
Matrix 2 of 5

Matrix 2 of 5 On/Off
On
* Off
Matrix 2 of 5 Check Character
No Check Character indicates that the scanner reads and transmits bar
code data with or without a check character.
When Check Character is set to Validate, but Don’t Transmit, the unit
only reads Matrix 2 of 5 bar codes printed with a check character, but will
not transmit the check character with the scanned data.
7 - 19
When Check Character is set to Validate and Transmit, the scanner only
reads Matrix 2 of 5 bar codes printed with a check character, and will transmit this character at the end of the scanned data. Default = No Check
Character.
* No Check Character
Validate, but Don’t Transmit
Validate and Transmit
Matrix 2 of 5 Redundancy
If you are encountering errors when reading Matrix 2 of 5 bar codes, you
may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce
the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the
Matrix 2 of 5 Redundancy bar code below, then scan a redundancy count
between 0 and 10 on the Programming Chart inside the back cover of this
manual. Then scan the Save bar code. Default = 0.
Matrix 2 of 5 Redundancy
Matrix 2 of 5 Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
7 - 20
Code 11

Code 11 On/Off
On
* Off
Check Digits Required
These options set whether 1 or 2 check digits are required with Code 11
bar codes. Auto Select Check Digits determines the number of check
digits based on the length of the bar code. If the bar code is 10 digits or
more, 2 check digits are required. If it is 9 digits or less, 1 check digit is
required. The check digit data is only transmitted if you program that feature (see Check Digit Validation on page 7-22). Default = Two Check Digits
Required.
One Check Digit Required
* Two Check Digits Required
Auto Select Check Digits
Required
7 - 21
Check Digit Validation
When Check Character is set to Validate and Transmit, the scanner will
only read Code 11 bar codes printed with the specified type check character(s), and will transmit the character(s) at the end of the scanned data.
Validate and Transmit One
Check Digit
Validate and Transmit Two
Check Digits
Validate and Transmit Auto
Select Check Digits
Code 11 Redundancy
If you are encountering errors when reading Code 11 bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the Code
11 Redundancy bar code below, then scan a redundancy count between 0
and 10 on the Programming Chart inside the back cover of this manual.
Then scan the Save bar code. Default = 0.
Code 11 Redundancy
7 - 22
Code 11 Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
7 - 23
Code 128

Code 128 On/Off
* On
Off
128 Group Separator Output
If you wish to transmit the group separator characters “GS” (0x1D hex) with
your Code 128 bar code output, scan the On bar code. When Off is
scanned, the group separator is not output. Default =Off.
On
* Off
Code 128 Redundancy
If you are encountering errors when reading Code 128 bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the Code
7 - 24
128 Redundancy bar code below, then scan a redundancy count between
0 and 10 on the Programming Chart inside the back cover of this manual.
Then scan the Save bar code. Default = 0.
Code 128 Redundancy
Code 128 Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
ISBT 128
ISBT is a variation of Code 128 that supports concatenation of neighboring
symbols on a blood product label. Use the bar codes below to turn ISBT 128
concatenation on or off. Default =Off.
On
* Off
7 - 25
Concatenation Timeout
When searching for bar codes during concatenation, you may wish to set a
delay used to find the next bar code. Set the length (in milliseconds) for
this delay by scanning the bar code below, then setting the timeout (from 165535 milliseconds) by scanning digits from the Programming Chart, then
scanning Save. Default = 750.
Concatenation Timeout
ISBT 128 Predefined Concatenation Sequences
Note: You must enable Code 128 and ISBT 128 to use this feature.
The following bar codes are used to select the pre-defined ISBT 128 Concatenation Sequence you wish to use. Once you have selected the concatenation sequence, use ISBT 128 Predefined Concatenation Sequences
On/Off to enable this feature. Default = Donation ID Number (001)
and ABO/RhD Blood Groups (002).
* Donation ID Number (001)
and ABO/RhD Blood Groups (002)
Donation ID Number (001) and
Donor ID Number (019)
Donation ID Number (001) and
Confidential Unit Exclusion
Status
Product Code (003) and
Expiration Date (Form 1)
Product Code (003) and
Expiration Date (Form 2)
Product Code (003) and
Expiration Date (Form 3)
Product Code (003) and
Expiration Date (Form 4)
7 - 26
ISBT 128 Predefined Concatenation Sequences On/
Off
The following selections allow you to enable or require the Predefined ISBT
128 Concatenation Sequences.
If you scan Off, the predefined concatenation sequences are disabled.
If you scan the Allow Predefined Sequence code, then the scanner will
output only the data combination specified in the predefined concatenation
sequence you selected.
If you scan the Require Predefined Sequence code, the data combination
specified in the predefined concatenation sequence you selected is
required to transmit the data. No data is output unless the sequence is
read.
Default = Off.
* Off
Allow Predefined Sequence
Require Predefined Sequence
ISBT 128 User-Defined Concatenation Sequences
Note: You must enable Code 128 and ISBT 128 to use this feature.
The following bar codes are used to create a custom ISBT 128 Concatenation Sequence. Select the identifiers you want to transmit in the 1st and
2nd positions, both left and right. Refer to the ISBT 128 Standard Technical
Specification for the list of data identifiers.
Use the ASCII Conversion Chart (Code Page 1252), beginning on page A4, to find the characters needed for the identifier. Locate the hex value for
each character and scan that 2 digit/character value from the Programming
Chart inside the back cover of this manual.
Example: You want to create a concatenation sequence that has the Donation Identification Number (001) as the left identifier, and Product Code
(003) as the right identifier.
The ISBT Index of Data Structures shows that for the Donation Identification Number, the first character is “=” and the second character can be from
A-N; P-Z; 1-9. For this example, use “G.” The Product Code first character
is “=” and the second character is “<.”
7 - 27
Step 1. Scan the 1st Left Identifier bar code, below.
Step 2. Use the Programming Chart to scan 3, D (hex for “=”).
Step 3. Scan Save.
Step 4. Scan the 2nd Left Identifier bar code, below.
Step 5. Use the Programming Chart to scan 4, 7 (hex for “G”).
Step 6. Scan Save.
Step 7. Scan the 1st Right Identifier bar code, below.
Step 8. Use the Programming Chart to scan 3, D (hex for “=”).
Step 9. Scan Save.
Step 10. Scan the 2nd Right Identifier bar code, below.
Step 11. Use the Programming Chart to scan 3, C (hex for “<”).
Step 12. Scan Save.
Once you have programmed the concatenation sequence, use ISBT 128
User-Defined Concatenation Sequences to enable this feature. Default =
0.
1st Left Identifier
2nd Left Identifier
1st Right Identifier
2nd Right Identifier
ISBT 128 User-Defined Concatenation Sequences
On/Off
The following selections allow you to enable or require the User-Defined
ISBT 128 Concatenation Sequences.
If you scan Off, the User-Defined concatenation sequences are disabled.
If you scan the Allow User-Defined Sequence code, then the scanner will
output only the data combination specified in the User-Defined concatenation sequence you created.
7 - 28
If you scan the Require User-Defined Sequence code, the data combination specified in the User-Defined concatenation sequence is required to
transmit the data. No data is output unless the sequence is read.
Default = Off.
* Off
Allow User-Defined Sequence
Require User-Defined Sequence
Content Verification
When the On bar code is scanned, the check character values are output
along with the bar code data, thus allowing you to verify that the check
character is in agreement with that calculated for the data stream. Default
= Off.
On
* Off
Transmit Identifiers
You may disable the transmission of the ISBT Code 128 data identifiers by
scanning Off. When this selection is Off, the first 2 data (ID) characters are
removed from the data stream unless the ISBT code contains the Donation
Identification Number identifiers. If the code contains the Donation Identifi-
7 - 29
cation Number identifiers, only the first ID character is removed from the
Donation Identification Number. The second character is transmitted as
normal data. Default = On.
* On
Off
Flag Digit Conversion
Type 3 flag digits are a part of the Donation Identification Number in an
ISBT 128 bar code. If you select On, the flag data is converted into a single MOD (37, 2) character and transmitted with the bar code data. Scan
Off if you do not want the flag digits transmitted. Default = Off.
On
* Off
7 - 30
GS1-128

GS1-128 On/Off
* On
Off
GS1-128 Application Identifier Parsing
This allows a single GS1-128 bar code to be broken into multiple transmissions based on the presence of application identifiers (AI) embedded in the
bar code. Scan Transmit Without Identifiers if you want the bar code broken into packets and stripped of the AI. If you want the AI included, scan
Transmit With Identifiers. Default = Off.
* Off
Transmit Without Identifiers
Transmit With Identifiers
GS1-128 Redundancy
If you are encountering errors when reading GS1-128 bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the GS1-
7 - 31
128 Redundancy bar code below, then scan a redundancy count between
0 and 10 on the Programming Chart inside the back cover of this manual.
Then scan the Save bar code. Default = 0.
GS1-128 Redundancy
GS1-128 Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
7 - 32
Telepen

Telepen On/Off
On
* Off
Telepen Output
Using AIM Telepen Output, the scanner reads symbols with start/stop pattern 1 and decodes them as standard full ASCII (start/stop pattern 1).
When Original Telepen Output is selected, the scanner reads symbols with
start/stop pattern 1 and decodes them as compressed numeric with
optional full ASCII (start/stop pattern 2). Default = AIM Telepen Output.
* AIM Telepen Output
Original Telepen Output
Telepen Redundancy
If you are encountering errors when reading Telepen bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the
7 - 33
Telepen Redundancy bar code below, then scan a redundancy count
between 0 and 10 on the Programming Chart inside the back cover of this
manual. Then scan the Save bar code. Default = 0.
Telepen Redundancy
Telepen Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
7 - 34
UPC-A

UPC-A On/Off
* On
Off
UPC-A Number System and Check Digit
UPC-A sample showing the number system and check digit:
Number
System
Check
Digit
UPC-A Number System
The numeric system digit of a U.P.C. symbol is normally transmitted at
the beginning of the scanned data, but the can be programmed so it
will not transmit it. Default = On.
* On
Off
7 - 35
UPC-A Check Digit
This selection allows you to specify whether the check digit should be
transmitted at the end of the scanned data or not. Default = On.
* On
Off
UPC-A Addenda
This selection adds 2 or 5 digits to the end of all scanned UPC-A data.
Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
UPC-A Addenda Required
When Required is scanned, the scanner will only read UPC-A bar codes
that have addenda. You must then turn on a 2 or 5 digit addenda listed on
page 7-36. Default = Not Required.
Required
* Not Required
7 - 36
Addenda Timeout
You can set a time during which the scanner looks for an addenda. If an
addenda is not found within this time period, the data can be either transmitted or discarded, based on the setting you are using for UPC-A
Addenda Required (see page 7-36). Set the length (in milliseconds) for this
timeout by scanning the bar code below, then setting the timeout (from 065535 milliseconds) by scanning digits from the Programming Chart, then
scanning Save. Default = 100.
Note: The Addenda Timeout setting is applied to all addenda and coupon
code searches.
Addenda Timeout
UPC-A Addenda Separator
When this feature is on, there is a space between the data from the bar
code and the data from the addenda. When turned off, there is no space.
Default = Off.
On
* Off
UPC-A Redundancy
If you are encountering errors when reading UPC-A bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the UPCA Redundancy bar code below, then scan a redundancy count between 0
and 10 on the Programming Chart inside the back cover of this manual.
Then scan the Save bar code. Default = 0.
UPC-A Redundancy
7 - 37
UPC-A/EAN-13 with Extended Coupon Code
Use the following codes to enable or disable UPC-A and EAN-13 with Extended
Coupon Code. When left on the default setting (Off), the scanner treats Coupon Codes and Extended Coupon Codes as single bar codes.
If you scan the Allow Concatenation code, when the scanner sees the coupon
code and the extended coupon code in a single scan, it transmits both as separate symbologies. Otherwise, it transmits the first coupon code it reads.
If you scan the Require Concatenation code, the scanner must see and read
the coupon code and extended coupon code in a single read to transmit the
data. No data is output unless both codes are read.
Default = Off.
* Off
Allow Concatenation
Require Concatenation
UPC-A Number System 4 Addenda Required
This setting programs the scanner to require a coupon code only on UPC-A
bar codes that begin with a “4.” The following settings can be programmed:
Require Coupon Code: All UPC-A bar codes that begin with a “4” must
have a coupon code. The UPC-A bar code with the coupon code is then
transmitted as a single, concatenated bar code. If a coupon code is not
found within the Addenda Timeout period, the UPC-A bar code is discarded.
Don’t Require Coupon Code: If you have selected Require Coupon
Code, and you want to disable this feature, scan Don’t Require Coupon
Code. UPC-A bar codes are transmitted, depending on the setting you are
using for UPC-A/EAN-13 with Extended Coupon Code.
7 - 38
Default = Don’t Require Coupon Code.
* Don’t Require Coupon Code
Require Coupon Code
UPC-A Number System 5 Addenda Required
This setting programs the scanner to require any combination of a coupon
code, a 2 digit addenda, or a 5 digit addenda on UPC-A bar codes that
begin with a “5.” The following settings can be programmed:
Require Coupon Code/Addenda: All UPC-A bar codes that begin with a
“5” must have a coupon code, a 2 digit addenda, a 5 digit addenda, or a
combination of these addenda. The UPC-A bar code with the coupon code
and/or addenda is then transmitted as a single, concatenated bar code. If a
coupon code and/or required addenda is not found within the Addenda
Timeout period, the UPC-A bar code is discarded.
Don’t Require Coupon Code/Addenda: If you have selected Require
Coupon Code/Addenda, and you want to disable this feature, scan Don’t
Require Coupon Code/Addenda. UPC-A bar codes are transmitted,
depending on the setting you are using for UPC-A/EAN-13 with Extended
Coupon Code.
7 - 39
Default = Don’t Require Coupon Code/Addenda.
* Don’t Require Coupon Code/
Addenda
Require 2 Digit Addenda
Require 5 Digit Addenda
Require 2 or 5 Digit Addenda
Require Coupon Code
Require Coupon Code or 2 Digit
Addenda
Require Coupon Code or 5 Digit
Addenda
Require Coupon Code, 2 Digit
Addenda, or 5 Digit Addenda
Addenda Timeout
You can set a time during which the scanner looks for a coupon code. If a
coupon code is not found within this time period, the data can be either
transmitted or discarded, based on the setting you are using for UPC-A/
EAN-13 with Extended Coupon Code or UPC-A Number System 4
Addenda Required. Set the length (in milliseconds) for this timeout by
7 - 40
scanning the bar code below, then setting the timeout (from 0-65535 milliseconds) by scanning digits from the Programming Chart, then scanning
Save. Default = 100.
Note: The Addenda Timeout setting is applied to all addenda and coupon
code searches.
Addenda Timeout
UPC-E0

UPC-E0 On/Off
Most U.P.C. bar codes lead with the 0 number system. To read these
codes, use the UPC-E0 On selection. If you need to read codes that lead
with the 1 number system, use EAN/JAN-13 (page 7-45). Default = On.
* UPC-E0 On
UPC-E0 Off
UPC-E0 Expand
UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format.
Default = Off.
On
* Off
7 - 41
UPC-E0 Number System
The numeric system digit of a UPC-A symbol is normally transmitted at the
beginning of scanned data. When using UPC-E Expand, the unit can be
programmed so it will not transmit it. Default = On.
* On
Off
UPC-E0 Number System and Check Digit
UPC-E0 sample showing the number system and check digit:
Number
System
Check
Digit
UPC-E0 Check Digit
Check Digit specifies whether the check digit should be transmitted at
the end of the scanned data or not. Default = Off.
On
* Off
7 - 42
UPC-E0 Leading Zero
This feature allows the transmission of a leading zero (0) at the beginning
of scanned data. To prevent transmission, scan Off. Default = Off.
On
* Off
UPC-E0 Addenda
This selection adds 2 or 5 digits to the end of all scanned UPC-E data.
Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
UPC-E0 Addenda Required
When Required is scanned, the scanner will only read UPC-E bar codes
that have addenda. Default = Not Required.
Required
* Not Required
7 - 43
Addenda Timeout
You can set a time during which the scanner looks for an addenda. If an
addenda is not found within this time period, the data can be either transmitted or discarded, based on the setting you are using for UPC-E0
Addenda Required (page 7-43). Set the length (in milliseconds) for this
timeout by scanning the bar code below, then setting the timeout (from 065535 milliseconds) by scanning digits from the Programming Chart, then
scanning Save. Default = 100.
Note: The Addenda Timeout setting is applied to all addenda and coupon
code searches.
Addenda Timeout
UPC-E0 Addenda Separator
When this feature is On, there is a space between the data from the bar
code and the data from the addenda. When turned Off, there is no space.
Default = Off.
On
* Off
UPC-E0 Redundancy
If you are encountering errors when reading UPC-E0 bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the UPCE0 Redundancy bar code below, then scan a redundancy count between
0 and 10 on the Programming Chart inside the back cover of this manual.
Then scan the Save bar code. Default = 1.
UPC-E0 Redundancy
7 - 44
EAN/JAN-13

EAN/JAN-13 On/Off
* On
Off
EAN/JAN-13 Check Digit
This selection allows you to specify whether the check digit should be
transmitted at the end of the scanned data or not. Default = On.
* On
Off
7 - 45
EAN/JAN-13 Addenda
This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13
data. Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
EAN/JAN-13 Addenda Required
When Required is scanned, the scanner will only read EAN/JAN-13 bar
codes that have addenda. Default = Not Required.
Required
* Not Required
EAN-13 Beginning with 2 Addenda Required
This setting programs the scanner to require a 2 digit addenda only on
EAN-13 bar codes that begin with a “2.” The following settings can be programmed:
Require 2 Digit Addenda: All EAN-13 bar codes that begin with a “2”
must have a 2 digit addendum. The EAN-13 bar code with the 2 digit
addendum is then transmitted as a single, concatenated bar code. If a 2
digit addendum is not found within the Addenda Timeout period, the EAN13 bar code is discarded.
Note: if you are using EAN-13 Beginning with 290 Addenda Required
(page 7-47), that setting will take precedence over this one.
7 - 46
Don’t Require 2 Digit Addenda: If you have selected Require 2 Digit
Addenda, and you want to disable this feature, scan Don’t Require 2 Digit
Addenda. EAN-13 bar codes are transmitted, depending on the setting
you are using for EAN/JAN-13 Addenda Required.
Default = Don’t Require 2 Digit Addenda.
* Don’t Require 2 Digit
Addenda
Require 2 Digit Addenda
EAN-13 Beginning with 290 Addenda Required
This setting programs the scanner to require a 5 digit addenda only on
EAN-13 bar codes that begin with “290.” The following settings can be programmed:
Require 5 Digit Addenda: All EAN-13 bar codes that begin with “290”
must have a 5 digit addendum. The EAN-13 bar code with the 5 digit
addendum is then transmitted as a single, concatenated bar code. If a 5
digit addendum is not found within the Addenda Timeout period, the EAN13 bar code is discarded.
Note: if you are using EAN-13 Beginning with 2 Addenda Required (page
7-46), this setting will take precedence.
Don’t Require 5 Digit Addenda: If you have selected Require 5 Digit
Addenda, and you want to disable this feature, scan Don’t Require 5 Digit
Addenda. EAN-13 bar codes are transmitted, depending on the setting
you are using for EAN/JAN-13 Addenda Required.
Default = Don’t Require 5 Digit Addenda.
* Don’t Require 5 Digit
Addenda
Require 5 Digit Addenda
EAN-13 Beginning with 378/379 Addenda Required
This setting programs the scanner to require any combination of a 2 digit
addenda or a 5 digit addenda on EAN-13 bar codes that begin with a “378”
or “379.” The following settings can be programmed:
7 - 47
Require Addenda: All EAN-13 bar codes that begin with a “378” or “379”
must have a 2 digit addenda, a 5 digit addenda, or a combination of these
addenda. The EAN-13 bar code with the addenda is then transmitted as a
single, concatenated bar code. If the required addenda is not found within
the Addenda Timeout period, the EAN-13 bar code is discarded.
Don’t Require Addenda: If you have selected Require Addenda, and
you want to disable this feature, scan Don’t Require Addenda. EAN-13
bar codes are transmitted, depending on the setting you are using for EAN/
JAN-13 Addenda Required.
Default = Don’t Require Addenda.
* Don’t Require Addenda
Require 2 Digit Addenda
Require 5 Digit Addenda
Require 2 or 5 Digit Addenda
EAN-13 Beginning with 414/419 Addenda Required
This setting programs the scanner to require any combination of a 2 digit
addenda or a 5 digit addenda on EAN-13 bar codes that begin with a “414”
or “419.” The following settings can be programmed:
Require Addenda: All EAN-13 bar codes that begin with a “414” or “419”
must have a 2 digit addenda, a 5 digit addenda, or a combination of these
addenda. The EAN-13 bar code with the addenda is then transmitted as a
single, concatenated bar code. If the required addenda is not found within
the Addenda Timeout period, the EAN-13 bar code is discarded.
Don’t Require Addenda: If you have selected Require Addenda, and
you want to disable this feature, scan Don’t Require Addenda. EAN-13
bar codes are transmitted, depending on the setting you are using for EAN/
JAN-13 Addenda Required.
7 - 48
Default = Don’t Require Addenda.
* Don’t Require Addenda
Require 2 Digit Addenda
Require 5 Digit Addenda
Require 2 or 5 Digit Addenda
EAN-13 Beginning with 434/439 Addenda Required
This setting programs the scanner to require any combination of a 2 digit
addenda or a 5 digit addenda on EAN-13 bar codes that begin with a “434”
or “439.” The following settings can be programmed:
Require Addenda: All EAN-13 bar codes that begin with a “434” or “439”
must have a 2 digit addenda, a 5 digit addenda, or a combination of these
addenda. The EAN-13 bar code with the addenda is then transmitted as a
single, concatenated bar code. If the required addenda is not found within
the Addenda Timeout period, the EAN-13 bar code is discarded.
Don’t Require Addenda: If you have selected Require Addenda, and
you want to disable this feature, scan Don’t Require Addenda. EAN-13
bar codes are transmitted, depending on the setting you are using for EAN/
JAN-13 Addenda Required.
7 - 49
Default = Don’t Require Addenda.
* Don’t Require Addenda
Require 2 Digit Addenda
Require 5 Digit Addenda
Require 2 or 5 Digit Addenda
EAN-13 Beginning with 977 Addenda Required
This setting programs the scanner to require a 2 digit addenda only on
EAN-13 bar codes that begin with “977.” The following settings can be programmed:
Require 2 Digit Addenda: All EAN-13 bar codes that begin with “977”
must have a 2 digit addendum. The EAN-13 bar code with the 2 digit
addendum is then transmitted as a single, concatenated bar code. If a 2
digit addendum is not found within the Addenda Timeout period, the EAN13 bar code is discarded.
Don’t Require 2 Digit Addenda: If you have selected Require 2 Digit
Addenda, and you want to disable this feature, scan Don’t Require 2 Digit
Addenda. EAN-13 bar codes are transmitted, depending on the setting
you are using for EAN/JAN-13 Addenda Required.
Default = Don’t Require 2 Digit Addenda.
* Don’t Require 2 Digit
Addenda
Require 2 Digit Addenda
EAN-13 Beginning with 978 Addenda Required
These settings program the scanner to require a 5 digit addenda only on
EAN-13 bar codes that begin with “978.” The following settings can be programmed:
7 - 50
Require 5 Digit Addenda: All EAN-13 bar codes that begin with “978”
must have a 5 digit addendum. The EAN-13 bar code with the 5 digit
addendum is then transmitted as a single, concatenated bar code. If a 5
digit addendum is not found within the Addenda Timeout period, the EAN13 bar code is discarded.
Don’t Require 5 Digit Addenda: If you have selected Require 5 Digit
Addenda, and you want to disable this feature, scan Don’t Require 5 Digit
Addenda. EAN-13 bar codes are transmitted, depending on the setting
you are using for EAN/JAN-13 Addenda Required.
Default = Don’t Require 5 Digit Addenda.
* Don’t Require 5 Digit
Addenda
Require 5 Digit Addenda
EAN-13 Beginning with 979 Addenda Required
These settings program the scanner to require a 5 digit addenda only on
EAN-13 bar codes that begin with “979.” The following settings can be programmed:
Require 5 Digit Addenda: All EAN-13 bar codes that begin with “979”
must have a 5 digit addendum. The EAN-13 bar code with the 5 digit
addendum is then transmitted as a single, concatenated bar code. If a 5
digit addendum is not found within the Addenda Timeout period, the EAN13 bar code is discarded.
Don’t Require 5 Digit Addenda: If you have selected Require 5 Digit
Addenda, and you want to disable this feature, scan Don’t Require 5 Digit
Addenda. EAN-13 bar codes are transmitted, depending on the setting
you are using for EAN/JAN-13 Addenda Required.
Default = Don’t Require 5 Digit Addenda.
* Don’t Require 5 Digit
Addenda
Require 5 Digit Addenda
7 - 51
Addenda Timeout
You can set a time during which the scanner looks for an addenda. If an
addenda is not found within this time period, the data can be either transmitted or discarded, based on the setting you are using for EAN/JAN-13
Addenda Required. Set the length (in milliseconds) for this timeout by
scanning the bar code below, then setting the timeout (from 0-65535 milliseconds) by scanning digits from the Programming Chart, then scanning
Save. Default = 100.
Note: The Addenda Timeout setting is applied to all addenda and coupon
code searches.
Addenda Timeout
EAN/JAN-13 Addenda Separator
When this feature is On, there is a space between the data from the bar
code and the data from the addenda. When turned Off, there is no space.
Default = Off.
On
* Off
Note: If you want to enable or disable EAN13 with Extended Coupon Code,
refer to UPC-A/EAN-13 with Extended Coupon Code (page 7-38).
EAN/JAN-13 Redundancy
If you are encountering errors when reading EAN/JAN-13 bar codes, you
may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce
the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the
EAN/JAN-13 Redundancy bar code below, then scan a redundancy count
between 0 and 10 on the Programming Chart inside the back cover of this
manual. Then scan the Save bar code. Default = 0.
EAN/JAN-13 Redundancy
7 - 52
ISBN Translate
ISBNs are printed on books using the EAN-13 bar code symbology. To
translate EAN-13 Bookland symbols into their equivalent ISBN number format, scan the On bar code below. Default = Off.
On
* Off
Convert ISBN to 13-Digit
When translating EAN-13 codes to the ISBN format, you can convert
the bar code to a 13 digit format by scanning the Convert to 13-Digit
On bar code below. Default = Convert to 13-Digit Off.
Convert to 13-Digit On
*Convert to 13-Digit Off
ISBN Reformat
In normal use, the first two or three digits of an EAN-13 bar code identify the country of origin. The country prefixes are 978 and 979. To
reformat ISBN codes so the country prefix is dropped out, scan the
Reformat On bar code below. Default = Reformat Off.
Reformat On
*Reformat Off
7 - 53
ISSN Translate
When On is scanned, EAN-13 977 Bookland symbols are translated into
their equivalent 8-digit ISSN number format. For example, 9770123456787
will be transmitted as 01234560. Default = Off.
On
* Off
ISSN Reformat
When Reformat On is scanned, EAN-13 977 Bookland symbols are
translated into their equivalent 8-digit ISSN number format, with
hyphens added to the output. For example, 9770123456787 will be
transmitted as 0123-456-0. (You must first scan ISSN On (page 7-54)
before scanning Reformat On.) Default = Reformat Off.
Reformat On
* Reformat Off
7 - 54
EAN/JAN-8

EAN/JAN-8 On/Off
* On
Off
EAN/JAN-8 Check Digit
This selection allows you to specify whether the check digit should be
transmitted at the end of the scanned data or not. Default = On.
* On
Off
7 - 55
EAN/JAN-8 Addenda
This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data.
Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
EAN/JAN-8 Addenda Required
When Required is scanned, the scanner will only read EAN/JAN-8 bar
codes that have addenda. Default = Not Required.
Required
* Not Required
Addenda Timeout
You can set a time during which the scanner looks for an addenda. If an
addenda is not found within this time period, the data can be either transmitted or discarded, based on the setting you are using for EAN/JAN-8
Addenda Required. Set the length (in milliseconds) for this timeout by
7 - 56
scanning the bar code below, then setting the timeout (from 0-65535 milliseconds) by scanning digits from the Programming Chart, then scanning
Save. Default = 100.
Note: The Addenda Timeout setting is applied to all addenda and coupon
code searches.
Addenda Timeout
EAN/JAN-8 Addenda Separator
When this feature is On, there is a space between the data from the bar
code and the data from the addenda. When turned Off, there is no space.
Default = Off.
On
* Off
EAN/JAN-8 Redundancy
If you are encountering errors when reading EAN/JAN-8 bar codes, you
may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce
the number of errors. Note that the higher the redundancy count, the longer it will take to decode the ba code. To adjust the redundancy, scan the
EAN/JAN-8 Redundancy bar code below, then scan a redundancy count
between 0 and 10 on the Programming Chart inside the back cover of this
manual. Then scan the Save bar code. Default = 0.
EAN/JAN-8 Redundancy
7 - 57
MSI

MSI On/Off
On
* Off
MSI Check Character
Different types of check characters are used with MSI bar codes. You can
program the scanner to read MSI bar codes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit.
When Check Character is set to Validate Type 10/11 and Transmit, the
scanner will only read MSI bar codes printed with the specified type check
character(s), and will transmit the character(s) at the end of the scanned
data.
7 - 58
When Check Character is set to Validate Type 10/11, but Don’t Transmit,
the unit will only read MSI bar codes printed with the specified type check
character(s), but will not transmit the check character(s) with the scanned
data.
* Validate Type 10, but Don’t
Transmit
Validate Type 10 and Transmit
Validate 2 Type 10 Characters,
but Don’t Transmit
Validate 2 Type 10 Characters
and Transmit
Validate Type 10 then Type 11
Character, but Don’t Transmit
Validate Type 10 then
Type 11 Character and Transmit
Disable MSI Check Characters
MSI Redundancy
If you are encountering errors when reading MSI bar codes, you may want
to adjust the redundancy count. Redundancy adjusts the number of times
a bar code is decoded before transmission, which may reduce the number
of errors. Note that the higher the redundancy count, the longer it will take
to decode the bar code. To adjust the redundancy, scan the MSI Redundancy bar code below, then scan a redundancy count between 0 and 10
on the Programming Chart inside the back cover of this manual. Then scan
the Save bar code. Default = 0.
MSI Redundancy
7 - 59
MSI Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
Plessey Code
< Default All Plessey Code Settings >
Plessey Code On/Off
On
* Off
Plessey Check Character
No Check Character indicates that the scanner reads and transmits bar
code data with or without a check character.
When Check Character is set to Validate, but Don’t Transmit, the unit
only reads Plessey bar codes printed with a check character, but will not
transmit the check character with the scanned data.
7 - 60
When Check Character is set to Validate and Transmit, the scanner only
reads Plessey bar codes printed with a check character, and will transmit
this character at the end of the scanned data. Default = No Check Character.
* No Check Character
Validate, but Don’t Transmit
Validate and Transmit
Plessey Redundancy
If you are encountering errors when reading Plessey bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the
Plessey Redundancy bar code below, then scan a redundancy count
between 0 and 10 on the Programming Chart inside the back cover of this
manual. Then scan the Save bar code. Default = 0.
Plessey Redundancy
Plessey Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
7 - 61
GS1 DataBar Omnidirectional
< Default All GS1 DataBar Omnidirectional Settings >
GS1 DataBar Omnidirectional On/Off
* On
Off
GS1 DataBar Omnidirectional Redundancy
If you are encountering errors when reading GS1 DataBar Omnidirectional
bar codes, you may want to adjust the redundancy count. Redundancy
adjusts the number of times a bar code is decoded before transmission,
which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the
redundancy, scan the GS1 DataBar Omnidirectional Redundancy bar
code below, then scan a redundancy count between 0 and 10 on the
Programming Chart inside the back cover of this manual. Then scan the
Save bar code. Default = 0.
GS1 DataBar Omnidirectional
Redundancy
7 - 62
GS1 DataBar Limited
< Default All GS1 DataBar Limited Settings >
GS1 DataBar Limited On/Off
* On
Off
GS1 DataBar Limited Redundancy
If you are encountering errors when reading GS1 DataBar Limited bar
codes, you may want to adjust the redundancy count. Redundancy adjusts
the number of times a bar code is decoded before transmission, which may
reduce the number of errors. Note that the higher the redundancy count,
the longer it will take to decode the bar code. To adjust the redundancy,
scan the GS1 DataBar Limited Redundancy bar code below, then scan a
redundancy count between 0 and 10 on the Programming Chart inside the
back cover of this manual. Then scan the Save bar code. Default = 0.
GS1 DataBar Limited
Redundancy
7 - 63
GS1 DataBar Expanded
< Default All GS1 DataBar Expanded Settings >
GS1 DataBar Expanded On/Off
* On
Off
GS1 DataBar Expanded Redundancy
If you are encountering errors when reading GS1 DataBar Expanded bar
codes, you may want to adjust the redundancy count. Redundancy adjusts
the number of times a bar code is decoded before transmission, which may
reduce the number of errors. Note that the higher the redundancy count,
the longer it will take to decode the bar code. To adjust the redundancy,
scan the GS1 DataBar Expanded Redundancy bar code below, then
scan a redundancy count between 0 and 10 on the Programming Chart
inside the back cover of this manual. Then scan the Save bar code.
Default = 0.
GS1 DataBar Expanded
Redundancy
7 - 64
GS1 DataBar Expanded Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
Trioptic Code
Trioptic Code is used for labeling magnetic storage media.
On
* Off
GS1 Emulation
The scanner can automatically format the output from any GS1 data carrier to
emulate what would be encoded in an equivalent GS1-128 or GS1 DataBar
symbol. GS1 data carriers include UPC-A and UPC-E, EAN-13 and EAN-8,
ITF-14, GS1-128, and GS1-128 DataBar and GS1 Composites. (Any application that accepts GS1 data can be simplified since it only needs to recognize
one data carrier type.)
If GS1-128 Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8,
EAN13) are expanded out to 16 digits. If the AIM ID is enabled, the value will be
the GS1-128 AIM ID, ]C1 (see Symbology Chart on page A-1).
If GS1 DataBar Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8,
EAN13) are expanded out to 16 digits. If the AIM ID is enabled, the value will be
the GS1-DataBar AIM ID, ]em (see Symbology Chart on page A-1).
If GS1 Code Expansion Off is scanned, retail code expansion is disabled, and
UPC-E expansion is controlled by the UPC-E0 Expand (page 7-41) setting. If
the AIM ID is enabled, the value will be the GS1-128 AIM ID, ]C1 (see
Symbology Chart on page A-1).
7 - 65
If EAN8 to EAN13 Conversion is scanned, all EAN8 bar codes are converted
to EAN13 format.
Default = GS1 Emulation Off.
GS1-128 Emulation
GS1 DataBar Emulation
GS1 Code Expansion Off
EAN8 to EAN13 Conversion
* GS1 Emulation Off
Postal Codes
The following lists linear postal codes. Any combination of linear postal code
selections can be active at a time.
China Post (Hong Kong 2 of 5)

7 - 66
China Post (Hong Kong 2 of 5) On/Off
On
* Off
China Post (Hong Kong 2 of 5) Redundancy
If you are encountering errors when reading China Post (Hong Kong 2
of 5) bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher
the redundancy count, the longer it will take to decode the bar code.
To adjust the redundancy, scan the China Post (Hong Kong 2 of 5)
Redundancy bar code below, then scan a redundancy count between
0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.
China Post (Hong Kong 2 of 5)
Redundancy
China Post (Hong Kong 2 of 5) Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description (page 7-2) for additional information.
Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80.
Minimum Message Length
Maximum Message Length
7 - 67
7 - 68
8
Interface Keys
Keyboard Function Relationships
The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII
“CTRL”+ relationships apply to all terminals that can be used with the scanner.
Refer to page 2-17 enable Control + ASCII mode.
Function Code
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HT
LF
VT
FF
CR
SO
SI
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
SUB
ESC
FS
GS
RS
US
HEX/ASCII Value
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
Full ASCII “CTRL” +
8-1
The last five characters in the Full ASCII “CTRL”+ column ( [ \ ] 6 - ), apply to
US only. The following chart indicates the equivalents of these five characters
for different countries.
Note: Not all countries may be supported by your device.
Country
Codes
United States
Belgium
Scandinavia
France
Germany
Ã
Italy
Switzerland
..
¢
United Kingdom
Denmark
Norway
Spain
Supported Interface Keys
ASCII
HEX
IBM AT/XT and
PS/2
Compatibles,
WYSE PC/AT
Supported Keys
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HT
LF
VT
FF
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
Reserved
Enter (KP)
Cap Lock
ALT make
ALT break
CTRL make
CTRL break
CR/Enter
Reserved
Tab
Reserved
Tab
Delete
8-2
Apple Mac/iMac
Supported Keys
Reserved
Enter/Numpad Enter
CAPS
ALT make
ALT break
CNTRL make
CNTRL break
RETURN
APPLE make
TAB
APPLE break
TAB
Del
ASCII
HEX
CR
SO
SI
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
SUB
ESC
FS
GS
RS
US
DEL
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
7F
IBM AT/XT and
PS/2
Compatibles,
WYSE PC/AT
Supported Keys
CR/Enter
Insert
Escape
F11
Home
Print
Back Space
Back Tab
F12
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
Apple Mac/iMac
Supported Keys
RETURN
Ins Help
ESC
F11
Home
Prnt Scrn
BACKSPACE
LSHIFT TAB
F12
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
BACKSPACE
8-3
8-4
9
Utilities
To Add a Test Code I.D. Prefix to All Symbologies
This selection allows you to turn on transmission of a Code I.D. before the
decoded symbology. (See the Symbology Chart, beginning on page A-1) for
the single character code that identifies each symbology.) This action first
clears all current prefixes, then programs a Code I.D. prefix for all symbologies.
This is a temporary setting that will be removed when the unit is power cycled.
Add Code I.D. Prefix to
All Symbologies (Temporary)
Show Software Revision
Scan the bar code below to output the current software revision, unit serial number, and other product information for both the scanner and base.
Show Revision
Show Data Format
Scan the bar code below to show current data format settings.
DFMBK3?.
Data Format Settings
9-1
Test Menu
When you scan the Test Menu On code, then scan a programming code in this
manual, the scanner displays the content of a programming code. The programming function will still occur, but in addition, the content of that programming code is output to the terminal.
Note: This feature should not be used during normal scanner operation.
On
* Off
EZConfig-Scanning Introduction
EZConfig-Scanning provides a wide range of PC-based programming functions
that can be performed on a scanner connected to your PC's COM port. EZConfig-Scanning allows you to download upgrades to the scanner's firmware,
change programmed parameters, and create and print programming bar codes.
Using EZConfig-Scanning, you can even save/open the programming parameters for a scanner. This saved file can be e-mailed or, if required, you can create a single bar code that contains all the customized programming parameters
and mail or fax that bar code to any location. Users in other locations can scan
the bar code to load in the customized programming.
To communicate with a scanner, EZConfig-Scanning requires that the PC have
at least one available serial communication port, or a serial port emulation using
a physical USB port. If you are using the serial port and RS232 cable, an external power supply is required. When using a USB serial port emulation, only a
USB cable is required.
EZConfig-Scanning Operations
The EZConfig-Scanning software performs the following operations:
Scan Data
Scan Data allows you to scan bar codes and display the bar code data
in a window. Scan Data lets you send serial commands to the scanner
and receive scanner response that can be seen in the Scan Data window. The data displayed in the Scan Data window can either be saved
in a file or printed.
Configure
Configure displays the programming and configuration data of the
scanner. The scanner's programming and configuration data is
grouped into different categories. Each category is displayed as a tree
9-2
item under the “Configure” tree node in the application explorer. When
one of these tree nodes is clicked, the right-hand side is loaded with
the parameters' form belonging to that particular category. The Configure tree option has all the programming and configuration parameters specified for a scanner. You can set or modify these parameters
as required. You can later write the modified settings to the scanner,
or save them to a dcf file.
Installing EZConfig-Scanning from the Web
Note: EZConfig-Scanning requires .NET framework. If .NET is not
installed on your PC, you will be prompted to install it during the
EZConfig-Scanning installation.
1. Access the Honeywell web site at www.honeywellaidc.com
2. Click on the Downloads tab. Select Software.
3. Click on the dropdown for Select Product Number and select the
number of your product.
4. Click on the listing for EZConfig-Scanning.
5. Follow the security directions as prompted on the screen.
6. When prompted, select Save, and save the file to the c:\windows\temp
directory.
7. Once you have finished downloading the file, exit the web site.
8. Using Explorer, go to the c:\windows\temp file.
9. Double click on the EZConfig-Scanning Setup.exe file. Follow the
screen prompts to install the EZConfig-Scanning program.
10. If you’ve selected the defaults during installation, you can click on Start
Menu-All Programs-Honeywell-EZConfig-Scanning.
9-3
9-4
10
Serial Programming Commands
The serial programming commands can be used in place of the programming
bar codes. Both the serial commands and the programming bar codes will program the scanner. For complete descriptions and examples of each serial programming command, refer to the corresponding programming bar code in this
manual.
The device must be set to an RS232 interface (see page 2-1). The following
commands can be sent via a PC COM port using terminal emulation software.
Conventions
The following conventions are used for menu and query command descriptions:
parameter A label representing the actual value you should send as part of a
command.
An optional part of a command.
[option]
{Data}
Alternatives in a command.
bold
Names of menus, menu commands, buttons, dialog boxes, and
windows that appear on the screen.
Menu Command Syntax
Menu commands have the following syntax (spaces have been used for clarity
only):
Prefix [:Name:] Tag SubTag {Data} [, SubTag {Data}] [; Tag SubTag {Data}] […]
Storage
Prefix Three ASCII characters: SYN M CR (ASCII 22,77,13).
:Name: To send information to the scanner (with the base connected to host),
use :Voyager: The default factory setting for a Voyager scanner is
Voyager scanner. If the name is not known, a wildcard (*) can be used
:*:.
Note: Since the base stores all work group settings and transfers to them to
scanner once they are linked, changes are typically done to the base and
not to the scanner.
Tag
A 3 character case-insensitive field that identifies the desired menu
command group. For example, all RS232 configuration settings are
identified with a Tag of 232.
SubTag A 3 character case-insensitive field that identifies the desired menu
command within the tag group. For example, the SubTag for the
RS232 baud rate is BAD.
Data
The new value for a menu setting, identified by the Tag and SubTag.
10 - 1
Storage A single character that specifies the storage table to which the
command is applied. An exclamation point (!) performs the command’s
operation on the device’s volatile menu configuration table. A period (.)
performs the command’s operation on the device’s non-volatile menu
configuration table. Use the non-volatile table only for semi-permanent
changes you want saved through a power cycle.
Query Commands
Several special characters can be used to query the device about its settings.
What is the default value for the setting(s).
What is the device’s current value for the setting(s).
What is the range of possible values for the setting(s). (The device’s
response uses a dash (-) to indicate a continuous range of values. A
pipe (|) separates items in a list of non-continuous values.)
:Name: Field Usage (Optional)
This command returns the query information from the scanner.
Tag Field Usage
When a query is used in place of a Tag field, the query applies to the entire
set of commands available for the particular storage table indicated by the
Storage field of the command. In this case, the SubTag and Data fields
should not be used because they are ignored by the device.
SubTag Field Usage
When a query is used in place of a SubTag field, the query applies only to
the subset of commands available that match the Tag field. In this case,
the Data field should not be used because it is ignored by the device.
Data Field Usage
When a query is used in place of the Data field, the query applies only to
the specific command identified by the Tag and SubTag fields.
Concatenation of Multiple Commands
Multiple commands can be issued within one Prefix/Storage sequence.
Only the Tag, SubTag, and Data fields must be repeated for each command in the sequence. If additional commands are to be applied to the
same Tag, then the new command sequence is separated with a comma (,)
and only the SubTag and Data fields of the additional command are issued.
If the additional command requires a different Tag field, the command is
separated from previous commands by a semicolon (;).
10 - 2
Responses
The device responds to serial commands with one of three responses:
ACK Indicates a good command which has been processed.
ENQ Indicates an invalid Tag or SubTag command.
NAK Indicates the command was good, but the Data field entry was out of
the allowable range for this Tag and SubTag combination, e.g., an
entry for a minimum message length of 100 when the field will only
accept 2 characters.
When responding, the device echoes back the command sequence with
the status character inserted directly before each of the punctuation marks
(the period, exclamation point, comma, or semicolon) in the command.
Examples of Query Commands
In the following examples, a bracketed notation [ ] depicts a non-displayable
response.
Example:
What is the range of possible values for Codabar Coding Enable?
Enter:
cbrena*.
Response: CBRENA0-1[ACK]
This response indicates that Codabar Coding Enable (CBRENA) has a range of
values from 0 to 1 (off and on).
Example:
What is the default value for Codabar Coding Enable?
Enter:
cbrena^.
Response: CBRENA1[ACK]
This response indicates that the default setting for Codabar Coding Enable
(CBRENA) is 1, or on.
Example:
What is the device’s current setting for Codabar Coding Enable?
Enter:
cbrena?.
Response: CBRENA1[ACK]
This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on.
Example:
What are the device’s settings for all Codabar selections?
Enter:
cbr?.
Response: CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
10 - 3
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
Serial Trigger Commands
You can activate and deactivate the scanner with serial trigger commands. The
button is activated and deactivated by sending the following commands:
Activate:
SYN T CR
Deactivate: SYN U CR
The scanner scans until a bar code has been read or until the deactivate command is sent. The scanner can also be set to turn itself off after a specified time
has elapsed (see Read Time-Out, which follows).
Read Time-Out
Use this selection to set a time-out (in milliseconds) of the scanner’s button
when using serial commands to trigger the scanner. Once the scanner has
timed out, you can activate the scanner either by pressing the button or
using a serial trigger command. After scanning the Read Time-Out bar
code, set the time-out duration (from 0-300,000 milliseconds) by scanning
digits on the Programming Chart inside the back cover, then scanning
Save. Default = 30,000 ms.
Read Time-Out
Resetting the Standard Product Defaults
If you aren’t sure what programming options are in your scanner, or you’ve
changed some options and want the factory default settings restored, scan the
Standard Product Default Settings bar code below.
Standard Product Default Settings
10 - 4
The charts on the following pages list the factory default settings for each of the
commands (indicated by an asterisk (*) on the programming pages).
10 - 5
Menu Commands
Selection
Setting
* Indicates default
Serial Command
# Indicates a numeric
entry
Page
Product Default Settings
Setting Custom
Defaults
Set Custom Defaults
MNUCDF
1-9
Save Custom
Defaults
DEFALT
1-9
Resetting the
Custom Defaults
Activate Custom
Defaults
DEFALT
1-10
Resetting the Factory
Defaults
Remove Custom
Defaults
DEFOVR
1-10
Activate Defaults
DEFALT
1-10
Keyboard Wedge:
IBM PC AT and
Compatibles with
CR suffix
PAP_AT
2-1
IBM PS2 Keyboard
PAPPS2
2-1
RS232 Serial Port
PAP232
2-2
IBM Port 5B
Interface
PAPP5B
2-2
IBM Port 9B
HHBCR-1 Interface
PAP9B1
2-2
IBM Port 17
Interface
PAPP17
2-2
IBM Port 9B
HHBCR-2 Interface
PAP9B2
2-2
OPOS Mode
OPOS Mode
PAPOPS
2-3
Plug and Play Codes:
IBM SurePos
USB IBM SurePos
Handheld
PAPSPH
2-4
USB IBM SurePos
Tabletop
PAPSPT
2-4
* Enable Secondary
Interface
REMIFC1
2-4
Disable Secondary
Interface
REMIFC0
2-4
Programming the Interface
Plug and Play Codes
Plug and Play Codes:
RS485
IBM Secondary
Interface
10 - 6
Selection
Plug and Play Codes:
USB
HID Fallback Mode
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
USB Keyboard (PC)
PAP124
2-5
USB Keyboard
(Mac)
PAP125
2-5
USB Japanese
Keyboard (PC)
PAP134
2-5
USB HID
PAP131
2-5
HID Fallback Mode
(Range 0-60 *5
minutes
USBFTO
2-6
10 - 7
Selection
USB Serial
Commands
10 - 8
Setting
Serial Command
# Indicates a numeric
entry
Page
USB Serial
Emulation for
Windows XP,
Windows Server
2003, and later
PAP130
2-6
USB Serial
Emulation for
Windows 2000
REMIFCO;PAP130
2-6
CTS/RTS Emulation
On
USBCTS1
2-6
CTS/RTS Emulation
Off*
USBCTS0
2-6
ACK/NAK Mode On
USBACK1
2-7
ACK/NAK Mode Off*
USBACK0
2-7
Communication
Timeout
(Range 0-65535)
*2000 ms
232DLK#####
2-7
Timeout Retries
HSTRTY
2-7
Communication
Timeout Beeper Off
HSTTOA0
2-8
*Communication
Timeout Beeper On
HSTTOA1
2-8
NAK Retries
(Range 0-255) *0
HSTRTN###
2-8
BEL/CAN Mode On
BELCAN1
2-8
BEL/CAN Mode Off*
BELCAN0
2-8
* Indicates default
Selection
Plug and Play Codes
Setting
Serial Command
# Indicates a numeric
entry
Page
Verifone Ruby
Terminal
PAPRBY
2-9
Gilbarco Terminal
PAPGLB
2-9
Honeywell Bioptic
Aux Port
PAPBIO
2-10
Datalogic Magellan
Bioptic Aux Port
PAPMAG
2-10
NCR Bioptic Aux
Port
PAPNCR
2-10
Wincor Nixdorf
Terminal
PAPWNX
2-11
Wincor Nixdorf
Beetle
PAPBTL
2-12
* Indicates default
10 - 9
Selection
Program Keyboard
Country
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
*U.S.A.
KBDCTY0
2-13
Arabic
KBDCTY91
2-13
Belgium
KBDCTY1
2-13
Chinese
KBDCTY92
2-13
Finland
KBDCTY2
2-13
France
KBDCTY3
2-13
Germany
KBDCTY4
2-13
Hungary
KBDCTY19
2-13
IBM Financial
KBDCTY90
2-13
Italy
KBDCTY5
2-13
Japan ASCII
KBDCTY28
2-13
Korea
KBDCTY93
2-13
Russia
KBDCTY26
2-14
Slovenia
KBDCTY31
2-14
Spain
KBDCTY10
2-14
Switzerland
(German)
KBDCTY6
2-14
Thailand
KBDCTY94
2-14
Turkey Q
KBDCTY24
2-14
United Kingdom
KBDCTY7
2-14
Vietnam
KBDCTY95
2-14
*Off
KBDALT0
2-15
3 Characters
KBDALT6
2-15
4 Characters
KBDALT7
2-15
*Regular
KBDSTY0
2-15
Caps Lock
KBDSTY1
2-15
Shift Lock
KBDSTY2
2-15
Autocaps via
NumLock
KBDSTY7
2-16
Emulate External
Keyboard
KBDSTY5
2-16
Keyboard Wedge Modifiers
ALT Mode
Keyboard Style
10 - 10
Selection
Keyboard Conversion
Keyboard Modifiers
Setting
Serial Command
# Indicates a numeric
entry
Page
*Keyboard
Conversion Off
KBDCNV0
2-16
Convert all
Characters to Upper
Case
KBDCNV1
2-16
Convert all
Characters to Lower
Case
KBDCNV1
2-16
* Indicates default
*Control + ASCII Off
KBDCAS0
2-17
DOS Mode Control
+ ASCII
KBDCAS1
2-17
Windows Mode
Control + ASCII
KBDCAS2
2-17
Windows Mode
Prefix/Suffix Off
KBDCAS3
2-17
*Numeric Keypad
Off
KBDNPS0
2-17
Numeric Keypad On
KBDNPS1
2-17
Inter-Scan Code
Delay
Inter-Scan Code
Delay
*0 (Range 1-30
msecs)
KBDDLY##
2-18
 Break
Character
Suppress 
Break Character
KBDF0B0
2-18
*Transmit 
Break Character
KBDF0B1
2-18
Reset Keyboard
Wedge Defaults
KBDDFT
2-18
Keyboard Wedge
Defaults
10 - 11
Selection
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
RS-232 Modifiers
RS232 Baud Rate
10 - 12
300 BPS
232BAD0
2-19
600 BPS
232BAD1
2-19
1200 BPS
232BAD2
2-19
2400 BPS
232BAD3
2-19
4800 BPS
232BAD4
2-19
*9600 BPS
232BAD5
2-19
19200 BPS
232BAD6
2-19
38400 BPS
232BAD7
2-19
57600 BPS
232BAD8
2-19
115200 BPS
232BAD9
2-19
Selection
Word Length: Data
Bits, Stop Bits, and
Parity
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
7 Data, 1 Stop,
Parity Even
232WRD3
2-20
7 Data, 1 Stop,
Parity None
232WRD0
2-20
7 Data, 1 Stop,
Parity Odd
232WRD6
2-20
7 Data, 2 Stop,
Parity Even
232WRD4
2-20
7 Data, 2 Stop,
Parity None
232WRD1
2-20
7 Data, 2 Stop,
Parity Odd
232WRD7
2-20
8 Data, 1 Stop,
Parity Even
232WRD5
2-20
*8 Data, 1 Stop,
Parity None
232WRD2
2-20
8 Data, 1 Stop,
Parity Odd
232WRD8
2-20
7 Data, 1 Stop,
Parity Space
232WRD9
2-20
7 Data, 2 Stop,
Parity Space
232WRD10
2-21
8 Data, 1 Stop,
Parity Space
232WRD11
2-21
7 Data, 1 Stop,
Parity Mark
232WRD12
2-21
7 Data, 2 Stop,
Parity Mark
232WRD13
2-21
8 Data, 1 Stop,
Parity Mark
232WRD14
2-21
10 - 13
Selection
RS232 Handshaking
RS232 Defaults
NCR Modifiers
10 - 14
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
*RTS/CTS Off
232CTS0
2-22
Flow Control, No
Timeout
232CTS1
2-22
Character-Based
Flow Control, No
Timeout
232CTS7
2-22
Two-Direction Flow
Control
232CTS2
2-22
Flow Control with
Timeout
232CTS3
2-22
Character-Based
Flow Control with
Timeout
232CTS9
2-22
RS232 Timeout
(Range 1-5100)
*1000 ms
232DEL####
2-22
*XON/XOFF Off
232XON0
2-23
XON/XOFF On
232XON1
2-23
*ACK/NAK Off
232ACK0
2-23
ACK/NAK On
232ACK1
2-23
Communication
Timeout
(Range 1-65535)
*2000 ms
232DLK#####
2-23
Communication
Timeout Beeper Off
HSTTOA0
2-24
*Communication
Timeout Beeper On
HSTTOA1
2-24
BEL/CAN Mode On
BELCAN1
2-25
*BEL/CAN Mode Off
BELCAN0
2-25
Reset RS232
Defaults
232DFT
2-25
Selection
NCR ACK/NAK
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
*NCR ACK/NAK Off
NCRACK0
2-25
NCR ACK/NAK On
NCRACK1
2-25
Block Check
Character
*Transmit
NCRBCC1
2-26
Don’t Transmit
NCRBCC0
2-26
NCR Prefix/Suffix
NCR Prefix
NCRPR2##
2-26
NCR Suffix
NCRSF2##
2-26
Transmit Prefix/
Suffix
NCRBCP1
2-27
*Don’t Transmit
Prefix/Suffix
NCRBCP0
2-27
NCR NOF (Not-onFile) Error
On
NCRRAZ1
2-27
*Off
NCRRAZ0
2-27
Scanner to Bioptic
Communication
*Packet Mode Off
232PKT0
2-28
Packet Mode On
232PKT2
2-28
*ACK/NAK Off
232ACK0
2-28
ACK/NAK On
232ACK1
2-28
Communication
Timeout
(Range 1-65535)
*2000 ms
232DLK#####
2-28
Cordless System Operation
Note: This section applies only to cordless systems. It does not apply to
corded scanners.
Base Power
Communication
Indicator
*On
:*:BASRED1
3-7
Off
:*:BASRED0
3-7
Reset Scanner
Reset Scanner
RESET_
3-8
Scanning While in
Base Cradle
Scanning in Cradle
Off
BT_SIC0
3-8
*Scanning in Cradle
On
BT_SIC1
3-8
*On
BEPPGE1
3-9
Off
BEPPGE0
3-9
Paging Mode
10 - 15
Setting
Serial Command
# Indicates a numeric
entry
Page
Low (*1000) (min
100Hz)
BEPPFQ1000
3-9
Medium (3250)
BEPPFQ3250
3-9
High (4200) (min
5000Hz)
BEPPFQ4200
3-9
Scanner Address
Scanner Address
BT_LDA
3-9
Base Address
Base Address
:*:BASLDA
3-10
Scanner Modes
Charge Only Mode
:*:BASLNK0
3-10
*Charge and Link
Mode
:*:BASLNK1
3-10
Locked Link Mode
:*:BASCON0
3-11
*Open Link Mode
:*:BASCON1
3-11
Unlink Scanner
BT_RMV
3-11
Override Locked
Scanner
BT_RPL1
3-12
Selection
Paging Pitch
Out-of-Range Alarm
Scanner Power
Time-Out Timer
Batch Mode
10 - 16
* Indicates default
*Alarm Off
BT_ORW0
3-12
Alarm On
BT_ORW1
3-12
Scanner Alarm
Duration (Range 1 3000 sec (*1))
BT_ORD
3-12
Timer (0-7200
seconds)
BT_LPT0
3-13
200 Seconds
BT_LPT200
3-13
400 Seconds
BT_LPT400
3-13
900 Seconds
BT_LPT900
3-13
3600 Seconds
BT_LPT3600
3-13
7200 Seconds
BT_LPT7200
3-13
Automatic Batch
Mode
BATENA1
3-14
*Batch Mode Off
BATENA0
3-14
Inventory Batch
Mode
BATENA2
3-14
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
Batch Mode Beep
Off
BATBEP0
3-14
*On
BATBEP1
3-14
Batch Mode Quantity
*Off
BATQTY0
3-15
On
BATQTY1
3-15
Quantity Codes
BATNUM0
3-16
BATNUM1
3-16
BATNUM2
3-16
BATNUM3
3-16
BATNUM4
3-16
BATNUM5
3-16
BATNUM6
3-16
BATNUM7
3-16
BATNUM8
3-16
BATNUM9
3-16
Delete Last Code
BATUND
3-17
*Record Counter Off
BATENT0
3-17
Record Counter On
BATENT1
3-17
Selection
Delete Last Code
Record Counter
Total Records
Total Records
BATNRC
3-17
Batch Mode Output
Order
FIFO
BATLIF0
3-18
LIFO
BATLIF1
3-18
Clear All Codes After
Transmission
*Don’t Clear All
Codes After
Transmission
BATCLX0
3-18
Clear All Codes
After Transmission
BATCLX1
3-18
Clear All Codes
Clear All Codes
BATCLR
3-18
Transmit Records
Automatically
*Don’t Transmit
Records
Automatically
BATATX0
3-19
Transmit Records
Automatically
BATATX1
3-19
Transmit Inventory
Records
BAT_TX
3-19
Transmit Records to
Host
10 - 17
Selection
Batch Mode Transmit
Delay
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
*Off
BATDLY0
3-20
Short (ms)
BATDLY250
3-20
Medium (ms)
BATDLY500
3-20
Long (ms)
BATDLY1000
3-20
Scanner Name
Scanner Name
BT_NAM
3-21
Bluetooth
Connection
Non-Base BT
Connection
BT_DNG9
3-22
Base BT Connection
BT_DNG8
3-22
Bluetooth PIN Code
Bluetooth PIN
*0000
BT_PIN
3-22
Auto Reconnect
Mode
*Auto Reconnect On
BT_ACM1
3-23
Auto Reconnect Off
BT_ACM0
3-23
Maximum Link
Attempts
Maximum Link
Attempts
Range 0-255 (*0)
BT_MLA###
3-24
Relink Time-Out
Relink Time-Out
Range 0-100 (*3)
BT_RLT###
3-24
Reset
Reset Base
RESET_
3-25
Reset Scanner
:*:RESET_
3-25
Power Up Beeper
Off - Scanner
BEPPWR0
4-1
*Power Up Beeper
On - Scanner
BEPPWR1
4-1
Beep on BEL
Character
Beep on BEL On
BELBEP1
4-1
*Beep on BEL Off
BELBEP0
4-1
Beeper - Good Read
Off
BEPBEP0
4-2
*On
BEPBEP1
4-2
Off
BEPLVL0
4-2
Low
BEPLVL1
4-2
Medium
BEPLVL2
4-2
*High
BEPLVL3
4-2
Input/Output Selections
Power Up Beeper
Beeper Volume Good Read
10 - 18
Selection
Beeper Pitch - Good
Read (Frequency)
Beeper - Transmit
Order
Beeper Pitch - Error
(Frequency)
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
Low (1600 Hz)
BEPFQ11600
4-3
*Medium (2350 Hz)
BEPFQ12350
4-3
High (4200 Hz)
BEPFQ14200
4-3
*Before
Transmission
BEPWHN1
4-3
After Transmission
BEPWHN2
4-3
*Razz (100 Hz)
BEPFQ2100
4-3
Medium (2000 Hz)
BEPFQ22000
4-3
High (4200 Hz)
BEPFQ24200
4-3
Beeper Duration Good Read
*Normal Beep
BEPBIP0
4-4
Short Beep
BEPBIP1
4-4
Number of Beeps Good Read
Range 1 - 9 (*1)
BEPRPT#
4-4
Number of Beeps Error
Range 1 - 9 (*1)
BEPERR#
4-5
10 - 19
Selection
LED Settings
10 - 20
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
Red LED Off
LEDFN10
4-6
Green LED Off
LEDFN20
4-6
Red LED On with
Good Scan
LEDFN11
4-6
*Green LED On with
Good Scan
LEDFN21
4-6
*Red LED On with
Laser
LEDFN12
4-6
Green LED On with
Laser
LEDFN22
4-6
Red LED On when
CodeGate Disabled
LEDFN14
4-6
Green LED On
when CodeGate
Disabled
LEDFN24
4-6
Red LED On when
In-Stand
LEDFN18
4-6
Green LED On
when In-Stand
LEDFN28
4-6
Red LED On with
CTS
LEDFN1128
4-7
Green LED On with
CTS
LEDFN2128
4-7
Red LED when
Battery is Low
LEDFN11024
Green LED when
Battery is Low
LEDFN21024
Selection
LED Brightness
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
Red Off
LEDIN10
4-8
Green Off
LEDIN20
4-8
Red Low
LEDIN11
4-8
Green Low
LEDIN21
4-8
Red Medium
LEDIN12
4-8
Green Medium
LEDIN22
4-8
*Red High
LEDIN13
4-8
*Green High
LEDIN23
4-8
10 - 21
Selection
In-Stand and Out-ofStand Settings
10 - 22
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
In-Stand Defaults
AISDFT
4-9
Out-of-Stand
Defaults
AOSDFT
4-9
Presentation Mode
Out-of-Stand
PAPPM1
4-9
Presentation Mode
with CodeGate Outof-Stand
PAPPM2
4-9
Manual Activation
Mode Off In-Stand
AISMEN0
4-10
*Manual Activation
Mode On In-Stand
AISMEN1
4-10
Manual Activation
Mode Off Out-ofStand
AOSMEN0
4-10
*Manual Activation
Mode On Out-ofStand
AOSMEN1
4-10
Do Not End Manual
Activation After
Good Read In-Stand
AISMGD0
4-10
*End Manual
Activation After
Good Read In-Stand
AISMGD1
4-10
Do Not End Manual
Activation After
Good Read Out-ofStand
AOSMGD0
4-10
*End Manual
Activation After
Good Read Out-ofStand
AOSMGD1
4-10
Laser Timeout Button Hold InStand
(Range 1 - 65525)
*5000 ms
AISMPT#####
4-11
Selection
In-Stand and Out-ofStand Settings
(continued)
Setting
Serial Command
# Indicates a numeric
entry
Page
Laser Timeout Button Release InStand
(Range 1 - 65525)
*0 ms
AISMRT#####
4-11
Laser Timeout Button Hold Out-ofStand
(Range 1 - 65525)
*5000 ms
AOSMPT#####
4-11
Laser Timeout Button Release Outof-Stand
(Range 1 - 65525)
*0 ms
AOSMRT#####
4-11
*CodeGate Off InStand
AISCGD0
4-12
CodeGate On InStand
AISCGD1
4-12
CodeGate Off Outof-Stand
AOSCGD0
4-12
*CodeGate On Outof-Stand
AOSCGD1
4-12
Object Detection
Mode Off In-Stand
AISOEN0
4-12
Object Detection
Mode On Out-ofStand
AOSOEN1
4-12
*Object Detection
Mode Off Out-ofStand
AOSOEN0
4-12
*Object Detection
Mode On In-Stand
AISOEN1
4-12
Do Not End Object
Detection After
Good Read In-Stand
AISOGD0
4-13
* Indicates default
10 - 23
Selection
In-Stand and Out-ofStand Settings
(continued)
10 - 24
Setting
Serial Command
# Indicates a numeric
entry
Page
*End Object
Detection After
Good Read In-Stand
AISOGD1
4-13
Do Not End Object
Detection After
Good Read Out-ofStand
AOSOGD0
4-13
*End Object
Detection After
Good Read Out-ofStand
AOSOGD1
4-13
Object Detection
Laser Timeout InStand
(Range 1 - 65525)
*5000 ms
AISODT#####
4-13
Object Detection
Laser Timeout Outof-Stand
(Range 1 - 65525)
*5000 ms
AOSODT#####
4-13
*Object Detection
Distance - Short InStand
AISRNG2
4-14
Object Detection
Distance - Long InStand
AISRNG1
4-14
Object Detection
Distance - Short
Out-of-Stand
AOSRNG2
4-14
*Object Detection
Distance - Long Outof-Stand
AOSRNG1
4-14
* Indicates default
Selection
Character Activation
Mode
Character
Deactivation Mode
Reread Delay
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
*Off
HSTCEN0
4-14
On
HSTCEN1
4-14
Activation Character
HSTACH##
4-15
Do Not End
Character Activation
After Good Read
HSTCGD0
4-15
*End Character
Activation After
Good Read
HSTCGD1
4-15
Character Activation
Laser Timeout
(Range 1 - 65525)
*5000 ms
HSTCDT#####
4-15
*Off
HSTDEN0
4-16
On
HSTDEN1
4-16
Deactivation
Character
HSTDCH##
4-16
Short (500 ms)
DLYRRD500
4-17
*Medium (750 ms)
DLYRRD750
4-17
Long (1000 ms)
DLYRRD1000
4-17
Extra Long (2000
ms)
DLYRRD2000
4-17
User-Specified
Reread Delay
Range 0 - 30,000
ms
DLYRRD#####
4-17
Output Sequence
Editor
Enter Sequence
SEQBLK
4-20
Default Sequence
SEQDFT
4-20
Sequence Timeout
(Range 1 - 65535)
*5000 ms
SEQDLY#####
4-20
Sequence Match
Beeper
*On
SEQBEP1
4-21
Off
SEQBEP0
4-21
Partial Sequence
Transmit Partial
Sequence
SEQTTS1
4-21
*Discard Partial
Sequence
SEQTTS0
4-21
10 - 25
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
Required
SEQ_EN2
4-22
On/Not Required
SEQ_EN1
4-22
*Off
SEQ_EN0
4-22
On
SHWNRD1
4-22
*Off
SHWNRD0
4-22
Add CR Suffix to All Symbologies
VSUFCR
5-3
Prefix
PREBK2##
5-3
Clear One Prefix
PRECL2
5-3
Clear All Prefixes
PRECA2
5-3
Add Suffix
SUFBK2##
5-4
Clear One Suffix
SUFCL2
5-4
Selection
Require Output
Sequence
No Read
Prefix/Suffix Selections
Suffix
Add Prefix
Clear All Suffixes
SUFCA2
5-4
Transmit Alternate
Extended ASCII
Characters
*Transmit Alternate
Extended ASCIi
KBDEXT0
5-4
Transmit Normal
Extended ASCIi
KBDEXT1
5-4
Function Code
Transmit
*Enable
RMVFNC0
5-6
Disable
RMVFNC1
5-6
Communication
Check Character
*None
HSTXRC0
5-6
LRC Starts on 1st
Character
HSTXRC1
5-6
LRC Starts on 2nd
Character
HSTXRC2
5-6
CRC
HSTXRC3
5-6
Intercharacter Delay
Range 0 - 1000
(5ms increments)
DLYCHR##
5-7
User Specified
Intercharacter Delay
Delay Length
0 - 1000 (5ms
increments)
DLYCRX##
5-8
Character to Trigger
Delay
DLY_XX##
5-8
10 - 26
Selection
Setting
* Indicates default
Serial Command
# Indicates a numeric
entry
Page
Interfunction Delay
Range 0 - 1000
(5ms increments)
DLYFNC##
5-8
Intermessage Delay
Range 0 - 1000
(5ms increments)
DLYMSG##
5-9
DFMDF3
6-1
Enter Data Format
DFMBK3##
6-2
Clear One Data
Format
DFMCL3
6-3
Clear All Data
Formats
DFMCA3
6-3
Data Formatter Selections
Data Format Editor
Data Formatter
Data Format NonMatch Error Tone
*Default Data
Format (None)
Data Formatter Off
DFM_EN0
6-8
*Data Formatter On,
Not Required,
Keep Prefix/Suffix
DFM_EN1
6-9
Data Format
Required,
Keep Prefix/Suffix
DFM_EN2
6-9
Data Formatter On,
Not Required,
Drop Prefix/Suffix
DFM_EN3
6-9
Data Format
Required,
Drop Prefix/Suffix
DFM_EN4
6-9
*Data Format NonMatch Error Tone
On
DFMDEC0
6-10
Data Format NonMatch Error Tone
Off
DFMDEC1
6-10
10 - 27
Selection
Primary/Alternate
Data Formats
Single Scan Data
Format Change
Setting
Serial Command
# Indicates a numeric
entry
Page
Primary Data
Format
ALTFNM0
6-10
Data Format 1
ALTFNM1
6-10
Data Format 2
ALTFNM2
6-10
Data Format 3
ALTFNM3
6-10
Single Scan-Primary
Data Format
VSAF_0
6-11
Single Scan-Data
Format 1
VSAF_1
6-11
Single Scan-Data
Format 2
VSAF_2
6-11
Single Scan-Data
Format 3
VSAF_3
6-11
All Symbologies Off
ALLENA0
7-1
All Symbologies On
ALLENA1
7-1
Default All Codabar
Settings
CBRDFT
7-3
Off
CBRENA0
7-3
*On
CBRENA1
7-3
*Don’t Transmit
CBRSSX0
7-3
Transmit
CBRSSX1
7-3
* Indicates default
Symbologies
All Symbologies
Codabar
Codabar Start/Stop
Char.
10 - 28
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
*No Check Char.
CBRCK20
7-4
Validate Modulo 16,
But Don’t Transmit
CBRCK21
7-4
Validate Modulo 16,
and Transmit
CBRCK22
7-4
Validate Modulo 7
CD, But Don’t
Transmit
CBRCK23
7-4
Validate Modulo 7
CD, and Transmit
CBRCK24
7-4
Validate CLSI, But
Don’t Transmit
CBRCK25
7-4
Validate CLSI, and
Transmit
CBRCK26
7-4
*Off
CBRCCT0
7-5
On
CBRCCT1
7-5
Require
CBRCCT2
7-5
Concatenation
Timeout
DLYCCT
7-5
Codabar
Redundancy
Range (0 - 10) *0
CBRVOT##
7-5
Codabar Message
Length
Minimum (1 - 80) *3
CBRMIN##
7-6
Maximum (1 - 80)
*80
CBRMAX##
7-6
Code 39
Default All Code 39
Settings
C39DFT
7-7
Off
C39ENA0
7-7
*On
C39ENA1
7-7
*Don’t Transmit
C39SSX0
7-7
Transmit
C39SSX1
7-7
Selection
Codabar Check
Char.
Codabar
Concatenation
Code 39 Start/Stop
Char.
10 - 29
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
*No Check Char.
C39CK20
7-8
Validate, But Don’t
Transmit
C39CK21
7-8
Validate,
and Transmit
C39CK22
7-8
Code 39
Redundancy
Range (0 - 10) *0
C39VOT##
7-8
Code 39 Message
Length
Minimum (1 - 80) *3
C39MIN##
7-8
Maximum (1 - 80)
*80
C39MAX##
7-8
Code 32
Pharmaceutical
(PARAF)
*Off
C39B320
7-9
On
C39B321
7-9
Code 39 Full ASCII
*Off
C39ASC0
7-10
On
C39ASC1
7-10
Default All
Interleaved
2 of 5 Settings
I25DFT
7-11
Off
I25ENA0
7-11
Selection
Code 39 Check Char.
Interleaved 2 of 5
*On
I25ENA1
7-11
Follett Formatting
*Off
I25FOL0
7-11
On
I25FOL1
7-11
NULL Characters
*Off
I25NUL0
7-11
On
I25NUL1
7-11
*No Check Char.
I25CK20
7-12
Validate, But Don’t
Transmit
I25CK21
7-12
Validate, and
Transmit
I25CK22
7-12
Interleaved 2 of 5
Redundancy
Range (0 - 10) *0
I25VOT##
7-12
Interleaved 2 of 5
Message Length
Minimum (1 - 80) *6
I25MIN##
7-13
Maximum (1 - 80)
*80
I25MAX##
7-13
Interleaved 2 of 5
Check Digit
10 - 30
Setting
Serial Command
# Indicates a numeric
entry
Page
Default All NEC
2 of 5 Settings
N25DFT
7-13
*Off
N25ENA0
7-13
On
N25ENA1
7-13
*No Check Char.
N25CK20
7-14
Validate, But Don’t
Transmit
N25CK21
7-14
Validate, and
Transmit
N25CK22
7-14
NEC 2 of 5
Redundancy
Range (0 - 10) *0
N25VOT##
7-14
NEC 2 of 5 Message
Length
Minimum (1 - 80) *3
N25MIN##
7-14
Maximum (1 - 80)
*80
N25MAX##
7-14
Code 93
Default All Code 93
Settings
C93DFT
7-15
Off
C93ENA0
7-15
*On
C93ENA1
7-16
Code 93
Redundancy
Range (0 - 10) *0
C93VOT##
7-15
Code 93 Message
Length
Minimum (1 - 80) *3
C93MIN##
7-16
Maximum (1 - 80)
*80
C93MAX##
7-16
Straight 2 of 5
Industrial
Default All Straight 2
of 5 Industrial
Settings
R25DFT
7-16
*Off
R25ENA0
7-16
On
R25ENA1
7-16
Straight 2 of 5
Industrial
Redundancy
Range (0 - 10) *0
R25VOT##
7-17
Straight 2 of 5
Industrial Message
Length
Minimum (3 - 80) *3
R25MIN##
7-17
Maximum (3 - 80)
*80
R25MAX##
7-17
Selection
NEC 2 of 5
NEC 2 of 5 Check
Digit
* Indicates default
10 - 31
Selection
Setting
* Indicates default
Serial Command
# Indicates a numeric
entry
Page
Straight 2 of 5 IATA
Default All Straight 2
of 5 IATA
Settings
A25DFT
7-18
Straight 2 of 5 IATA
*Off
A25ENA0
7-18
On
A25ENA1
7-18
Straight 2 of 5 IATA
Redundancy
Range (0 - 10) *0
A25VOT##
7-18
Straight 2 of 5 IATA
Message Length
Minimum (1 - 80)
*13
A25MIN##
7-19
Maximum (1 - 80)
*15
A25MAX##
7-19
Default All Matrix 2
of 5
Settings
X25DFT
7-19
*Off
X25ENA0
7-19
Matrix 2 of 5
On
X25ENA1
7-19
Matrix 2 of 5
Redundancy
Range (0 - 10) *0
X25VOT##
7-20
Matrix 2 of 5
Message Length
Minimum (1 - 80) *3
X25MIN##
7-20
Maximum (1 - 80)
*80
X25MAX##
7-20
Matrix 2 of 5 Check
Char.
*No Check Char.
X25CK20
7-20
Validate, But Don’t
Transmit
X25CK21
7-20
Validate and
Transmit
X25CK22
7-20
Default All Code 11
Settings
C11DFT
7-21
*Off
C11ENA0
7-21
On
C11ENA1
7-21
Code 11
10 - 32
Setting
Serial Command
# Indicates a numeric
entry
Page
1 Check Digit
Required
C11CK20
7-21
*2 Check Digits
Required
C11CK21
7-21
Auto Select Check
Digits Required
C11CK22
7-21
Validate and
Transmit One Check
Digit
C11CK23
7-22
Validate and
Transmit Two Check
Digits
C11CK24
7-22
Validate and
Transmit Auto Select
Check Digits
C11CK25
7-22
Code 11
Redundancy
Range (0 - 10) *0
C11VOT##
7-22
Code 11 Message
Length
Minimum (1 - 80) *3
C11MIN##
7-23
Maximum (1 - 80)
*80
C11MAX##
7-23
Code 128
Default All Code 128
Settings
128DFT
7-24
Off
128ENA0
7-24
Selection
Code 11 Check
Digits Required
Check Digit
Validation
* Indicates default
*On
128ENA1
7-24
128 Group Separator
Output
*Off
128GSE0
7-24
On
128GSE1
7-24
Code 128
Redundancy
Range (0 - 10) *0
128VOT##
7-25
Code 128 Message
Length
Minimum (1 - 80) *3
128MIN##
7-25
Maximum (1 - 80)
*80
128MAX##
7-25
ISBT 128
*Off
ISBENA0
7-25
On
ISBENA1
7-25
Concatenation
Timeout
DLYCCT
7-26
10 - 33
Selection
ISBT128 Predefined
Concatenation
Sequences
ISBT 128 Predefined
Concatenation
Sequences On/Off
10 - 34
Setting
Serial Command
# Indicates a numeric
entry
Page
* Donation ID
Number (001)
and ABO/RhD Blood
Groups (002)
ISBPCS0
7-26
Donation ID Number
(001) and
Donor ID Number
(019)
ISBPCS1
7-26
Donation ID Number
(001) and
Confidential Unit
Exclusion Status
ISBPCS2
7-26
Product Code (003)
and Expiration Date
(Form 1)
ISBPCS3
7-26
Product Code (003)
and Expiration Date
(Form 2)
ISBPCS4
7-26
Product Code (003)
and Expiration Date
(Form 3)
ISBPCS5
7-26
Product Code (003)
and Expiration Date
(Form 4)
ISBPCS6
7-26
*Off
ISBPCE0
7-27
Allow Predefined
Sequence
ISBPCE1
7-27
Require Predefined
Sequence
ISBPCE2
7-27
* Indicates default
Setting
Serial Command
# Indicates a numeric
entry
Page
1st Left Identifier (0255) *0
ISBUL1##
7-28
2nd Left Identifier (0255) *0
ISBUL2##
7-28
1st Right Identifier
(0-255) *0
ISBUR1##
7-28
2nd Right Identifier
(0-255) *0
ISBUR2##
7-28
ISBT 128 UserDefined
Concatenation
Sequences On/Off
*Off
ISBUCE0
7-29
Allow User-Defined
Sequence
ISBUCE1
7-29
Require UserDefined Sequence
ISBUCE2
7-29
Content Verification
*Off
ISBXM00
7-29
On
ISBXM01
7-29
Transmit Identifiers
Off
ISBXM10
7-30
*On
ISBXM11
7-30
Flag Conversion
*Off
ISBXM20
7-30
On
ISBXM21
7-30
GS1-128
Default All GS1-128
Settings
GS1DFT
7-31
*On
GS1ENA1
7-31
Off
GS1ENA0
7-31
*Off
GS1EMU0
7-31
Transmit Without
Identifiers
GS1EMU1
7-31
Transmit With
Identifiers
GS1EMU2
7-31
GS1-128
Redundancy
Range (0 - 10) *0
GS1VOT##
7-32
GS1-128 Message
Length
Minimum (1 - 80) *3
GS1MIN
7-32
Maximum (0 - 80)
*80
GS1MAX
7-32
Selection
ISBT 128 UserDefined
Concatenation
Sequences
GS1-128 Application
Identifier Parsing
* Indicates default
10 - 35
Setting
Serial Command
# Indicates a numeric
entry
Page
TELDFT
7-33
*Off
TELENA0
7-33
On
TELENA1
7-33
*AIM Telepen Output
TELOLD0
7-33
Original Telepen
Output
TELOLD1
7-33
Telepen Redundancy
Range (0 - 10) *0
TELVOT##
7-34
Telepen Message
Length
Minimum (1 - 80) *3
TELMIN##
7-34
Maximum (1 - 80)
*80
TELMAX##
7-34
UPC-A
Default All
UPC-A Settings
UPADFT
7-35
Off
UPAENA0
7-36
*On
UPAENA1
7-36
UPC-A Number
System
Off
UPANSX0
7-35
*On
UPANSX1
7-35
UPC-A Check Digit
Off
UPACKX0
7-35
*On
UPACKX1
7-36
Selection
Telepen
Telepen Output
* Indicates default
Default All Telepen
Settings
UPC-A 2 Digit
Addenda
*Off
UPAAD20
7-36
On
UPAAD21
7-36
UPC-A 5 Digit
Addenda
*Off
UPAAD50
7-36
On
UPAAD51
7-36
UPC-A Addenda
Required
*Not Required
UPAARQ0
7-36
Required
UPAARQ1
7-36
Addenda Timeout
Range (0 - 65535)
*100
DLYADD#####
7-37
UPC-A Addenda
Separator
*Off
UPAADS0
7-37
On
UPAADS1
7-37
UPC-A Redundancy
Range (0 - 10) *0
UPAVOT##
7-37
10 - 36
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
UPC-A/EAN-13 with
Extended Coupon
Code
*Off
CPNENA0
7-38
Allow Concatenation
CPNENA1
7-38
Require
Concatenation
CPNENA2
7-38
UPC-A Number
System 4 Addenda
Required
* Don’t Require
Coupon Code
ARQSY40
7-39
Require Coupon
Code
ARQSY41
7-39
UPC-A Number
System 5 Addenda
Required
* Don’t Require
Coupon Code/
Addenda
ARQSY50
7-40
Require 2 Digit
Addenda
ARQSY51
7-40
Require 5 Digit
Addenda
ARQSY52
7-40
Require 2 or 5 Digit
Addenda
ARQSY53
7-40
Require Coupon
Code
ARQSY54
7-40
Require Coupon
Code or 2 Digit
Addenda
ARQSY55
7-40
Require Coupon
Code or 5 Digit
Addenda
ARQSY56
7-40
Require Coupon
Code, 2 Digit
Addenda, or 5 Digit
Addenda
ARQSY57
7-40
Addenda Timeout
Range (0 - 65535)
*100
DLYADD#####
7-41
UPC-E0
Default All UPC-E
Settings
UPEDFT
7-41
Off
UPEEN00
7-41
*On
UPEEN01
7-41
Selection
10 - 37
Selection
UPC-E0 Expand
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
*Off
UPEEXP0
7-41
On
UPEEXP1
7-41
UPC-E0 Number
System
*On
UPEEXN1
7-42
Off
UPEEXN0
7-42
UPC-E0 Check Digit
*Off
UPECKX0
7-42
On
UPECKX1
7-42
UPC-E0 Leading
Zero
*Off
UPENSX0
7-43
On
UPENSX1
7-43
UPC-E0 Addenda
2 Digit Addenda On
UPEAD21
7-43
*2 Digit Addenda Off
UPEAD20
7-43
5 Digit Addenda On
UPEAD51
7-43
*5 Digit Addenda Off
UPEAD50
7-43
UPC-E0 Addenda
Required
Required
UPEARQ1
7-43
*Not Required
UPEARQ0
7-43
Addenda Timeout
Range (0 - 65535)
*100
DLYADD#####
7-44
UPC-E0 Addenda
Separator
On
UPEADS1
7-44
*Off
UPEADS0
7-44
UPC-E0
Redundancy
Range (0 - 10) *1
UPEVOT##
7-44
EAN/JAN-13
Default All EAN/
JAN Settings
E13DFT
7-45
Off
E13ENA0
7-45
*On
E13ENA1
7-45
EAN/JAN-13 Check
Digit
Off
E13CKX0
7-45
*On
E13CKX1
7-45
EAN/JAN-13 2 Digit
Addenda
2 Digit Addenda On
E13AD21
7-46
*2 Digit Addenda Off
E13AD20
7-46
5 Digit Addenda On
E13AD51
7-46
*5 Digit Addenda Off
E13AD50
7-46
*Not Required
E13ARQ0
7-46
Required
E13ARQ1
7-46
EAN/JAN-13
Addenda Required
10 - 38
Selection
Setting
* Indicates default
Serial Command
# Indicates a numeric
entry
Page
EAN-13 Beginning
with 2 Addenda
Required
* Don’t Require 2
Digit Addenda
ARQSY20
7-47
Require 2 Digit
Addenda
ARQSY21
7-47
EAN-13 Beginning
with 290 Addenda
Required
* Don’t Require 5
Digit Addenda
ARQ2900
7-47
Require 5 Digit
Addenda
ARQ2901
7-47
EAN-13 Beginning
with 378/379
Addenda Required
* Don’t Require
Addenda
ARQ3780
7-48
Require 2 Digit
Addenda
ARQ3781
7-48
Require 5 Digit
Addenda
ARQ3782
7-48
Require 2 or 5 Digit
Addenda
ARQ3783
7-48
* Don’t Require
Addenda
ARQ4140
7-49
Require 2 Digit
Addenda
ARQ4141
7-49
Require 5 Digit
Addenda
ARQ4142
7-49
Require 2 or 5 Digit
Addenda
ARQ4143
7-49
* Don’t Require
Addenda
ARQ4340
7-50
Require 2 Digit
Addenda
ARQ4341
7-50
Require 5 Digit
Addenda
ARQ4342
7-50
Require 2 or 5 Digit
Addenda
ARQ4343
7-50
EAN-13 Beginning
with 414/419
Addenda Required
EAN-13 Beginning
with 434/439
Addenda Required
10 - 39
Selection
Setting
* Indicates default
Serial Command
# Indicates a numeric
entry
Page
EAN-13 Beginning
with 977 Addenda
Required
* Don’t Require 2
Digit Addenda
ARQ9770
7-50
Require 2 Digit
Addenda
ARQ9771
7-50
EAN-13 Beginning
with 978 Addenda
Required
* Don’t Require 5
Digit Addenda
ARQ9780
7-51
Require 5 Digit
Addenda
ARQ9781
7-51
EAN-13 Beginning
with 979 Addenda
Required
* Don’t Require 5
Digit Addenda
ARQ9790
7-51
Require 5 Digit
Addenda
ARQ9791
7-51
Addenda Timeout
Range (0 - 65535)
*100
DLYADD#####
7-52
EAN/JAN-13
Addenda
Separator
*Off
E13ADS0
7-52
On
E13ADS1
7-53
EAN/JAN-13
Redundancy
Range (0 - 10) *0
E13VOT##
7-52
ISBN Translate
*Off
E13ISB0
7-53
On
E13ISB1
7-53
Convert to 13-Digit
On
E13I131
7-53
*Convert to 13-Digit
Off
E13I130
7-53
Reformat On
E13IBR1
7-53
*Reformat Off
E13IBR0
7-53
*Off
E13ISS0
7-54
On
E13ISS1
7-54
Reformat On
E13ISR1
7-54
*Reformat Off
E13ISR0
7-54
ISSN Translate
10 - 40
Setting
Serial Command
# Indicates a numeric
entry
Page
Default All EAN/
JAN 8 Settings
EA8DFT
7-55
Off
EA8ENA0
7-55
*On
EA8ENA1
7-55
Off
EA8CKX0
7-55
*On
EA8CKX1
7-55
*2 Digit Addenda Off
EA8AD20
7-56
2 Digit Addenda On
EA8AD21
7-56
*5 Digit Addenda Off
EA8AD50
7-56
5 Digit Addenda On
EA8AD51
7-56
EAN/JAN-8 Addenda
Required
*Not Required
EA8ARQ0
7-56
Required
EA8ARQ1
7-56
Addenda Timeout
Range (0 - 65535)
*100
DLYADD#####
7-57
EAN/JAN-8 Addenda
Separator
*Off
EA8ADS0
7-57
On
EA8ADS1
7-57
EAN/JAN-8
Redundancy
Range (0 - 10) *0
EA8VOT##
7-57
MSI
Default All MSI
Settings
MSIDFT
7-58
*Off
MSIENA0
7-58
On
MSIENA1
7-58
Selection
EAN/JAN-8
EAN/JAN-8 Check
Digit
EAN/JAN-8 Addenda
* Indicates default
10 - 41
Setting
Serial Command
# Indicates a numeric
entry
Page
*Validate Type 10,
but Don’t Transmit
MSICHK0
7-59
Validate Type 10 and
Transmit
MSICHK1
7-59
Validate 2 Type 10
Chars, but Don’t
Transmit
MSICHK2
7-59
Validate 2 Type 10
Chars and Transmit
MSICHK3
7-59
Validate Type 10
then Type 11 Char,
but Don’t Transmit
MSICHK4
7-59
Validate Type 10
then Type 11 Char
and Transmit
MSICHK5
7-59
Disable MSI Check
Characters
MSICHK6
7-59
MSI Redundancy
Range (0 - 10) *0
MSIVOT##
7-59
MSI Message Length
Minimum (1 - 80) *3
MSIMIN##
7-60
Maximum (1 - 80)
*80
MSIMAX##
7-60
Default All
Plessey Code
Settings
PLSDFT
7-60
Off
PLSENA0
7-60
*On
PLSENA1
7-60
*No Check Char.
PLSCHK0
7-61
Validate, But Don’t
Transmit
PLSCHK1
7-61
Validate,
and Transmit
PLSCHK2
7-61
Selection
MSI Check Character
Plessey Code
Plessey Check Char.
* Indicates default
Plessey Redundancy
Range (0 - 10) *0
PLSVOT##
7-61
Plessey Message
Length
Minimum (1 - 80) *3
PLSMIN##
7-61
Maximum (1 - 80)
*80
PLSMAX##
7-61
10 - 42
Selection
GS1 DataBar
Omnidirectional
Setting
Serial Command
# Indicates a numeric
entry
Page
Default All
GS1 DataBar
Omnidirectional
Settings
RSSDFT
7-62
Off
RSSENA0
7-62
* Indicates default
*On
RSSENA1
7-62
GS1 DataBar
Omnidirectional
Redundancy
Range (0 - 10) *0
RSSVOT##
7-62
GS1 DataBar Limited
Default All GS1
DataBar Limited
Settings
RSLDFT
7-63
Off
RSLENA0
7-63
*On
RSLENA1
7-63
GS1 DataBar Limited
Redundancy
Range (0 - 10) *0
RSLVOT##
7-63
GS1 DataBar
Expanded
Default All GS1
DataBar
Expanded Settings
RSEDFT
7-64
Off
RSEENA0
7-64
*On
RSEENA1
7-64
GS1 DataBar
Expanded
Redundancy
Range (0 - 10) *0
RSEVOT##
7-64
GS1 DataBar
Expanded Msg.
Length
Minimum (1 - 80) *3
RSEMIN##
7-65
Maximum (1 - 80)
*80
RSEMAX##
7-65
Trioptic Code
*Off
TRIENA0
7-65
On
TRIENA1
7-65
10 - 43
Setting
Serial Command
* Indicates default
# Indicates a numeric
entry
Page
GS1-128 Emulation
EANEMU1
7-66
GS1 DataBar
Emulation
EANEMU2
7-66
GS1 Code
Expansion Off
EANEMU3
7-66
EAN8 to EAN13
Conversion
EANEMU4
7-66
*GS1 Emulation Off
EANEMU0
7-66
Default All China
Post (Hong Kong 2
of 5) Settings
CPCDFT
7-66
*Off
CPCENA0
7-67
On
CPCENA1
7-67
China Post (Hong
Kong 2 of 5)
Redundancy
Range (0 - 10) *0
CPCVOT##
7-67
China Post (Hong
Kong 2 of 5) Msg.
Length
Minimum (1 - 80) *3
CPCMIN##
7-67
Maximum (1 - 80)
*80
CPCMAX##
7-67
TRGSTO####
10-4
Selection
GS1 Emulation
Postal Codes
China Post (Hong
Kong 2 of 5)
Serial Trigger Commands
Read Time-Out
10 - 44
0 - 300,000
*30,000 ms
11
Product Specifications
Voyager 1200g Scanner Product Specifications
Parameter
Specification
Mechanical
Height
3.8 in. (97mm)
Length
7.1 in. (180mm)
Width
2.6 in. (66mm)
Weight
4.41 oz. (125g)
Electrical
Input Voltage
5V + 5%
Operating Power
700mW; 140 mA (typical) @ 5V
Standby Power
350mW; 70 mA (typical) @ 5V
Environmental
Operating Temperature
32°F to 122°F (0°C to 50°C)
Storage Temperature
-4°F to 140°F (-20°C to 60°C)
Humidity
0 to 95% non-condensing
Drop
Operational after 30 drops to concrete from 5 ft.
(1.5m)
Environmental Sealing
IP42
Light Levels
0 - 70,000 lux (direct sunlight)
ESD
16kV, 9kV contact
Scan Performance
Scan Pattern
Single scan line
Scan Angle
Horizontal: 30°
Scan Speed
100 scan lines per second
Print Contrast
10% minimum reflectance difference
Pitch, Skew
60°, 60°
Decode Capabilities
Reads standard 1D and GS1 DataBar symbologies
DOF with 3.5 mil resolution at standard range
Typical Performance
5 mil Code 39
27 - 151mm (1.1 - 5.9 in.)
7.5 mil Code 39
16 - 216mm (.6 - 8.5 in.)
10.4 mil Code 39
0 - 277mm (0 - 10.9 in.)
13 mil UPC-A
0 - 311mm (0 - 12.2 in.)
20 mil Code 39
0 - 367mm (0 - 14.4 in.)
11 - 1
Parameter
Specification
Guaranteed Performance
5 mil Code 39
38 - 132mm (1.5 - 5.2 in.)
7.5 mil Code 39
26 - 189mm (1 - 7.4 in.)
10.4 mil Code 39
0 - 229mm (0 - 9 in.)
13 mil UPC-A
0 - 253mm (0 - 10 in.)
20 mil Code 39
0 - 293mm (0 - 11.5 in.)
Laser Beam
Wavelength
645 - 660 nm
Divergence
< 1.5 mrad. per IEC 60825-1 worst case
Maximum Power Output
< 1 mw
Embedded Laser
Wavelength
645 - 660 nm
Divergence
< 1.5 mrad. per IEC 60825-1 worst case
Maximum Power Output
10 mw
11 - 2
Voyager 1202g Scanner Product Specifications
Parameter
Specification
Mechanical
Height
3.6 in. (92mm)
Length
7.1 in. (180mm)
Width
2.6 in. (65mm)
Weight (with battery)
6.3 oz. (178.6g)
Battery
Lithium Ion
1800 mAHr minimum
Number of Scans
Up to 45,000 per charge
Expected Hours of Operation
12
Expected Charge Time
4 hours (external supply)
8 hours (USB power)
Radio
Frequency
2.4 to 2.5 GHz (ISM Band) Frequency Hopping
Bluetooth v.2.1
Range
33 ft. (10 m) typical line of sight
Data Rate
Up to 3 MBps
Environmental
Temperature Ranges:
Operating - Charging
32° F to +113° F (0° C to 45° C)
Operating - Non-Charging
32° F to +122° F (0° C to 50° C)
Storage*
23°F to +95°F (-5°C to 35°C)
Humidity
Up to 95% non-condensing
Mechanical Drop
Operational after 30 drops from 5 feet
(1.5m) to concrete
Environmental Sealing
IP42
ESD Sensitivity
16kV air
9kV contact
Scan Performance
Pitch, Skew
60°, 60°
11 - 3
Parameter
Specification
Scan Pattern
Single scan line
Scan Angle
Horizontal: 30°
Scan Speed
100 scan lines per second
Print Contrast
10% minimum reflectance difference
Decode Capabilities
Reads standard 1D and GS1 DataBar symbologies
DOF with 3.5 mil resolution at standard range
Typical Performance
5 mil Code 39
27 - 151mm (1.1 - 5.9 in.)
7.5 mil Code 39
16 - 216mm (.6 - 8.5 in.)
1.40 mil Code 39
0 - 277mm (0 - 10.9 in.)
13 mil UPC-A
0 - 311mm (0 - 12.2 in.)
20 mil Code 39
0 - 367mm (0 - 14.4 in.)
Guaranteed Performance
5 mil Code 39
38 - 132mm (1.5 - 5.2 in.)
7.5 mil Code 39
26 - 189mm (1 - 7.4 in.)
10.4 mil Code 39
0 - 229mm (0 - 9 in.)
13 mil UPC-A
0 - 253mm (0 - 10 in.)
20 mil Code 39
0 - 293mm (0 - 11.5 in.)
Laser Beam
Wavelength
645 - 660 nm
Divergence
< 1.5 mrad. per IEC 60825-1 worst case
Maximum Power Output
< 1 mw
Embedded Laser
Wavelength
645 - 660 nm
Divergence
< 1.5 mrad. per IEC 60825-1 worst case
Maximum Power Output
10 mw
CCB00-010BT Charge Base Product
Specifications
Parameter
Specification
Mechanical
Dimensions (Typical):
Height
3.8 inches (98mm)
Length
7.9 inches (200mm)
Width
2.6 inches (67mm)
11 - 4
Weight
6.5 oz (185g)
Electrical
Input Voltage
5 volts +5%
Operating Power - Charging
5W (1A@5V) (external supply)
2.5W (0.5A@5V) (USB power)
Non-Charging Power
0.5W (1A@5V)
Expected Charge Time
4 hours (external supply)
8 hours (USB power)
Radio
Frequency
2.4 to 2.5 GHz (ISM Band) Frequency Hopping
Bluetooth v.2.1
Range
33 ft. (10 m) typical (line of sight)
Data Rate
Up to 3 MBps
Temperature Ranges:
Operating - Charging
32° F to +113° F (0° C to 45° C)
Operating - Non-Charging
32° F to +122° F (0° C to 50° C)
Storage*
23°F to +95°F (-5°C to 35°C)
Humidity
Up to 95% non-condensing
Environmental
Mechanical Drop
Operational after 30 drops from 3.28 feet
(1m) to concrete
ESD Sensitivity
16kV air
9kV contact
11 - 5
CCB00-010BT Charge Base Mounting
3.07 in (78mm)
Use 2 M3x15mm
PHP, self-tapping
wood screws
11 - 6
Cable shield
Cable select
Supply ground
Terminal data
Terminal clock
Keyboard clock
Supply power input +5V power
Keyboard data
Note: Pin assignments are not compatible with Honeywell legacy products.
Use of a cable with improper pin assignments may lead to damage to the unit.
Use of any cables not provided by the manufacturer may result in damage not
covered by your warranty.
10
connects to the base
10 Pin RJ41 Modular Plug
Standard Cable Pinouts
Keyboard Wedge
11 - 7
11 - 8
Cable shield
Cable select
Supply ground
Transmit data
Receive data - serial data to scanner
CTS
+5V power
RTS
Note: Pin assignments are not compatible with Honeywell legacy products.
Use of a cable with improper pin assignments may lead to damage to the unit.
Use of any cables not provided by the manufacturer may result in damage not
covered by your warranty.
10
connects to the base
10 Pin RJ41 Modular Plug
Standard Cable Pinouts
Serial Output
+5V power
Transmit Enable
Cable shield
Cable select
Supply ground
Transmit data
Receive data - serial data to scanner
Note: RS485 signal conversion is performed in the cable.
Pin assignments are not compatible with Honeywell legacy products.
Use of a cable with improper pin assignments may lead to damage to the unit.
Use of any cables not provided by the manufacturer may result in damage not
covered by your warranty.
10
connects to the base
10 Pin RJ41 Modular Plug
Standard Cable Pinouts
RS485 Output
11 - 9
11 - 10
Data +
Data -
+5V power
Cable shield
Cable select
Supply ground
Note: Pin assignments are not compatible with Honeywell legacy products.
Use of a cable with improper pin assignments may lead to damage to the unit.
Use of any cables not provided by the manufacturer may result in damage not
covered by your warranty.
connects to the base
10 Pin Modular Plug
10
Standard Cable Pinouts
USB
12
Maintenance
Repairs
Repairs and/or upgrades are not to be performed on this product. These services are to be performed only by an authorized service center (see Customer
Support on page 13-1).
Maintenance
Your device provides reliable and efficient operation with a minimum of care.
Although specific maintenance is not required, the following periodic checks
ensure dependable operation:
Cleaning the Device
Reading performance may degrade if the scanner’s window is not clean. If
the window is visibly dirty, or if the scanner isn’t operating well, clean the
window with a soft cloth or lens tissue dampened with water (or a mild
detergent- water solution). If a detergent solution is used, rinse with a
clean lens tissue dampened with water only.
The scanner and base’s housing may also be cleaned the same way.
Caution:
Do not submerge the scanner in water. The scanner’s
housing is not watertight.
Do not use abrasive wipes or tissues on the scanner’s
window – abrasive wipes may scratch the window. Never
use solvents (e.g., alcohol or acetone) on the housing or
window – solvents may damage the finish or the window.
Inspecting Cords and Connectors
Inspect the interface cable and connector for wear or other signs of damage. A badly worn cable or damaged connector may interfere with scanner
operation. Contact your distributor for information about cable replacement. Cable replacement instructions are on page 12-1.
Replacing Cables in Corded Scanners
The standard interface cable is attached to the scanner with an 10-pin modular
connector. When properly seated, the connector is held in the scanner’s handle
by a flexible retention tab. The interface cable is designed to be field replaceable.
12 - 1
• Order replacement cables from Honeywell or from an authorized distributor.
• When ordering a replacement cable, specify the cable part number of the
original interface cable.
Replacing an Interface Cable in a Corded Scanner
1. Turn the power to the host system OFF.
2. Disconnect the scanner’s cable from the
terminal or computer.
3. Locate the small hole on the underside of
the scanner’s handle. This is the cable
release.
4. Straighten one end of a paper clip.
5. Insert the end of the paper clip into the small
hole and press in. This depresses the
retention tab, releasing the connector. Pull
the connector out while maintaining
pressure on the paper clip, then remove the
paper clip.
Cable
Release
6. Replace with the new cable.
Insert the connector into the opening and press firmly. The connector is
keyed to go in only one way, and will click into place.
Replacing Cables in Cordless Systems
Replacing an Interface Cable in a Base
1. Turn the power to the host system OFF.
2. Disconnect the base’s cable from the terminal or computer.
12 - 2
3. Turn the base upside down.
4. Locate the pinhole for the cable
release and insert a straightened
paper clip.
5. Pull the connector out while
maintaining pressure on the
connector release clip.
6. Replace with the new cable.
Insert the connector into the opening
and press firmly. The connector is
keyed to go in only one way, and will
click into place.
Troubleshooting a Voyager
Scanner
The scanner automatically performs
self-tests whenever you turn it on. If
your scanner is not functioning properly,
review the following Troubleshooting
Guide to try to isolate the problem.
Is the power on? Is the laser aimer
on?
If the laser aimer isn’t illuminated, check that:
• The cable is connected properly.
• The host system power is on (if external power isn’t used).
• The button works.
Is the scanner having trouble reading your symbols?
If the scanner isn’t reading symbols well, check that the scanner window is
clean and that the symbols:
• Aren’t smeared, rough, scratched, or exhibiting voids.
• Aren’t coated with frost or water droplets on the surface.
• Are enabled in the scanner or in the decoder to which the scanner
connects.
12 - 3
Is the bar code displayed but not entered?
The bar code is displayed on the host device correctly, but you still have to
press a key to enter it (the Enter/Return key or the Tab key, for example).
• You need to program a suffix. Programming a suffix enables the scanner
to output the bar code data plus the key you need (such as “CR”) to enter
the data into your application. Refer to Prefix/Suffix Overview on page
5-1 for further information.
Does the scanner read the bar code incorrectly?
If the scanner reads a bar code, but the data is not displayed correctly on
the host screen:
• The scanner may not be programmed for the appropriate terminal
interface.
For example, you scan “12345” and the host displays “@es%.”
Reprogram the scanner with the correct Plug and Play bar code. See
Programming the Interface beginning on page 2-1.
• The scanner may not be programmed to output your bar code data
properly.
For example, you scan “12345” and the host displays “A12345B.”
Reprogram the scanner with the proper symbology selections. See
Chapter 7.
The scanner won’t read your bar code at all.
1. Scan the sample bar codes in the back of this manual. If the scanner
reads the sample bar codes, check that your bar code is readable.
Verify that your bar code symbology is enabled (see Chapter 7).
2. If the scanner still can’t read the sample bar codes, scan All
Symbologies On, page 7-1.
The cordless scanner won’t scan bar codes while it is in the base cradle
1. Scanning While in Cradle Off may be programmed.
2. Scan the * Scanning in Cradle On (page 3-8) bar code so the scanner
will also scan bar codes while in the base cradle.
If you aren’t sure what programming options have been set in the scanner,
or if you want the factory default settings restored, refer to Setting Custom
Defaults on page 1-9.
Troubleshooting a Cordless System
Troubleshooting a Base
Note: Visit the Services and Support section of our website
(www.honeywellaidc.com) to check for the latest software for both
the scanner and the base.
12 - 4
If your base is not functioning properly, review the following troubleshooting
guidelines to try to isolate the problem.
Is the red LED on?
If the red LED isn’t illuminated, check that:
• The power cable is connected properly and there is power at the power
source.
• The host system power is on (if external power isn’t used).
Is the green LED on?
If the green LED isn’t illuminated, check that:
• The scanner is correctly placed in the base.
• There is external power or 12 volt host power.
• Charge mode is turned on. (See "Flash Updates" on page 3-6)
• The battery is not bad or deeply discharged. In some cases, the
scanner’s battery may trickle charge to bring it into an acceptable level
and then transition to a normal charge cycle.
Troubleshooting a Cordless Scanner
Note: Make sure that your scanner’s battery is charged.
Visit the Services and Support section of our website
(www.honeywellaidc.com) to check for the latest software for both
the scanner and the base or Access Point.
Is the scanner having trouble reading your symbols?
If the scanner isn’t reading symbols well, check that the symbols:
• Aren’t smeared, rough, scratched, or exhibiting voids.
• Aren’t coated with frost or water droplets on the surface.
• Are enabled in the base or Access Point to which the scanner connects.
Is the bar code displayed but not entered into the application?
The bar code is displayed on the host device correctly, but you still have to
press a key to enter it (the Enter/Return key or the Tab key, for example).
• You need to program a suffix. Programming a suffix enables the scanner
to output the bar code data plus the key you need (such as “CR”) to enter
the data into your application. Refer to Prefix/Suffix Overview on page 51 for further information.
Does the scanner read the bar code incorrectly?
If the scanner reads a bar code, but the data is not displayed correctly on
the host screen:
• The base or Access Point may not be programmed for the appropriate
terminal interface. For example, you scan “12345” and the host displays
“@es%.”
Reprogram the base/Access Point with the correct Plug and Play bar code.
See Programming the Interface beginning on page 2-1.
12 - 5
• The bas or Access Pointe may not be programmed to output your bar
code data properly. For example, you scan “12345” and the host
displays “A12345B.”
Reprogram the base/Access Point with the proper symbology selections.
See Chapter 7.
The scanner won’t read your bar code at all.
• Scan the sample bar codes in the back of this manual. If the scanner
reads the sample bar codes, check that your bar code is readable.
Verify that your bar code symbology is enabled (see Chapter 7).
If the scanner still can’t read the sample bar codes, scan All
Symbologies on page 7-1.
12 - 6
13
Customer Support
Technical Assistance
If you need assistance installing or troubleshooting your device, please call your
distributor or the nearest technical support office:
North America/Canada
Telephone: (800) 782-4263
E-mail: hsmnasupport@honeywell.com
Latin America
Telephone: (803) 835-8000
Telephone: (800) 782-4263
E-mail: hsmlasupport@honeywell.com
Brazil
Telephone: +55 (11) 5185-8222
Fax: +55 (11) 5185-8225
E-mail: brsuporte@honeywell.com
Mexico
Telephone: 01-800-HONEYWELL (01-800-466-3993)
E-mail: soporte.hsm@honeywell.com
Europe, Middle East, and Africa
Telephone: +31 (0) 40 7999 393
Fax: +31 (0) 40 2425 672
E-mail: hsmeurosupport@honeywell.com
Hong Kong
Telephone: +852-29536436
Fax: +852-2511-3557
E-mail: aptechsupport@honeywell.com
Singapore
Telephone: +65-6842-7155
Fax: +65-6842-7166
E-mail: aptechsupport@honeywell.com
China
Telephone: +86 800 828 2803
Fax: +86-512-6762-2560
E-mail: aptechsupport@honeywell.com
Japan
Telephone: +81-3-6730-7344
Fax: +81-3-6730-7222
E-mail: aptechsupport@honeywell.com
13 - 1
Online Technical Assistance
You can also access technical assistance online at www.honeywellaidc.com.
Product Service and Repair
Honeywell International Inc. provides service for all its products through service
centers throughout the world. To obtain warranty or non-warranty service,
contact the appropriate location below to obtain a Return Material Authorization
number (RMA #) before returning the product.
North America
Telephone: (800) 782-4263
E-mail: hsmnaservice@honeywell.com
Latin America
Telephone: (803) 835-8000
Telephone: (800) 782-4263
Fax: (239) 263-9689
E-mail: laservice@honeywell.com
Brazil
Telephone: +55 (11) 5185-8222
Fax: +55 (11) 5185-8225
E-mail: brservice@honeywell.com
Mexico
Telephone: 01-800-HONEYWELL (01-800-466-3993)
Fax: +52 (55) 5531-3672
E-mail: mxservice@honeywell.com
Europe, Middle East, and Africa
Telephone: +31 (0) 40 2901 633
Fax: +31 (0) 40 2901 631
E-mail: euroservice@honeywell.com
Hong Kong
Telephone: +852-29536436
Fax: +852-2511-3557
E-mail: apservice@honeywell.com
Singapore
Telephone: +65-6842-7155
Fax: +65-6842-7166
E-mail: apservice@honeywell.com
China
Telephone: +86 800 828 2803
Fax: +86-512-6762-2560
E-mail: apservice@honeywell.com
13 - 2
Japan
Telephone: +81-3-6730-7344
Fax: +81-3-6730-7222
E-mail: apservice@honeywell.com
Online Product Service and Repair Assistance
You can also access product service and repair assistance online at
www.honeywellaidc.com.
Limited Warranty
Honeywell International Inc. (“HII”) warrants its products to be free from defects
in materials and workmanship and to conform to HII’s published specifications
applicable to the products purchased at the time of shipment. This warranty
does not cover any HII product which is (i) improperly installed or used; (ii) damaged by accident or negligence, including failure to follow the proper maintenance, service, and cleaning schedule; or (iii) damaged as a result of (A)
modification or alteration by the purchaser or other party, (B) excessive voltage
or current supplied to or drawn from the interface connections, (C) static electricity or electro-static discharge, (D) operation under conditions beyond the
specified operating parameters, or (E) repair or service of the product by anyone other than HII or its authorized representatives.
This warranty shall extend from the time of shipment for the duration published
by HII for the product at the time of purchase (“Warranty Period”). Any defective
product must be returned (at purchaser’s expense) during the Warranty Period
to HII factory or authorized service center for inspection. No product will be
accepted by HII without a Return Materials Authorization, which may be
obtained by contacting HII. In the event that the product is returned to HII or its
authorized service center within the Warranty Period and HII determines to its
satisfaction that the product is defective due to defects in materials or workmanship, HII, at its sole option, will either repair or replace the product without
charge, except for return shipping to HII.
EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW, THE
FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR
WARRANTIES, EITHER EXPRESSED OR IMPLIED, ORAL OR WRITTEN,
INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR NONINFRINGEMENT.
HII’S RESPONSIBILITY AND PURCHASER’S EXCLUSIVE REMEDY UNDER
THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF THE
DEFECTIVE PRODUCT WITH NEW OR REFURBISHED PARTS. IN NO
EVENT SHALL HII BE LIABLE FOR INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, AND, IN NO EVENT, SHALL ANY LIABILITY OF HII
ARISING IN CONNECTION WITH ANY PRODUCT SOLD HEREUNDER
(WHETHER SUCH LIABILITY ARISES FROM A CLAIM BASED ON CONTRACT, WARRANTY, TORT, OR OTHERWISE) EXCEED THE ACTUAL
AMOUNT PAID TO HII FOR THE PRODUCT. THESE LIMITATIONS ON LIA-
13 - 3
BILITY SHALL REMAIN IN FULL FORCE AND EFFECT EVEN WHEN HII MAY
HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH INJURIES, LOSSES,
OR DAMAGES. SOME STATES, PROVINCES, OR COUNTRIES DO NOT
ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY
NOT APPLY TO YOU.
All provisions of this Limited Warranty are separate and severable, which
means that if any provision is held invalid and unenforceable, such determination shall not affect the validity of enforceability of the other provisions hereof.
Use of any peripherals not provided by the manufacturer may result in damage
not covered by this warranty. This includes but is not limited to: cables, power
supplies, cradles, and docking stations. HII extends these warranties only to the
first end-users of the products. These warranties are non-transferable.
The duration of the limited warranty for the Voyager 1200g scanner is five (5)
years.
The duration of the limited warranty for the Voyager 1202g scanner and CCB00010BT Charge Base is three (3) years.
The duration of the limited warranty for the Voyager battery is one (1) year.
13 - 4
A
Reference Charts
Symbology Chart
Note: Not all symbologies may be supported by your device.
Symbology
AIM ID
Possible
AIM ID
Modifiers
( m)
All Symbologies
Code ID
(hex)
(0x99)
Australian Post
]X0
Aztec Code
]zm
British Post
]X0
B (0x42)
Canadian Post
]X0
C (0x43)
China Post
]X0
Q (0x51)
Chinese Sensible Code (Han Xin
Code)
]X0
H (0x48)
Codabar
]Fm
0-1
a (0x61)
Codablock A
]O6
0, 1, 4, 5, 6
V (0x56)
Codablock F
]Om
0, 1, 4, 5, 6
q (0x71)
Code 11
]H3
Code 128
]Cm
GS1-128
A (0x41)
0-9, A-C
z (0x7A)
h (0x68)
0, 1, 2, 4
j (0x6A)
]C1
I (0x49)
Code 32 Pharmaceutical (PARAF)
]X0
< (0x3C)
Code 39 (supports Full ASCII
mode)
]Am
0, 1, 3, 4, 5, 7
Code 49
]Tm
0, 1, 2, 4
l (0x6C)
Code 93 and 93i
]Gm
0-9, A-Z,
a-m
i (0x69)
Data Matrix
]dm
0-6
w (0x77)
EAN-13 (including Bookland EAN)
b (0x62)
]E0
d (0x64)
EAN-13 with Add-On
]E3
d (0x64)
EAN-13 with Extended
Coupon Code
]E3
d (0x64)
A-1
Possible
AIM ID
Modifiers
( m)
Code ID
(hex)
Symbology
AIM ID
EAN-8
]E4
D (0x44)
]E3
D (0x44)
EAN-8 with Add-On
GS1 Composite
]em
0-3
y (0x79)
GS1 DataBar
]em
y (0x79)
GS1 DataBar Limited
]em
{ (0x7B)
GS1 DataBar Omnidirectional
]em
y (0x79)
GS1 DataBar Expanded
]em
} (0x7D)
InfoMail
]X0
, (0x2c)
Intelligent Mail Bar Code
]X0
M (0x4D)
Interleaved 2 of 5
]Im
0, 1, 3
e (0x65)
Japanese Post
]X0
J (0x4A)
KIX (Netherlands) Post
]X0
K (0x4B)
Korea Post
]X0
? (0x3F)
Matrix 2 of 5
]X0
m (0x6D)
MaxiCode
]Um
0-3
x (0x7 8)
MicroPDF417
]Lm
3-5
R (0x52)
MSI
]Mm
g (0x67)
NEC 2 of 5
]X0
Y (0x59)
OCR MICR (E 13 B)
]o3
O (0x4F)
OCR SEMI Font
]o3
O (0x4F)
OCR-A
]o1
O (0x4F)
OCR-B
]o2
O (0x4F)
PDF417
]Lm
Planet Code
]X0
L (0x4C)
Postal-4i
]X0
N (0x4E)
Postnet
]X0
P (0x50)
QR Code and Micro QR Code
]Qm
0-6
s (0x73)
Straight 2 of 5 IATA
]Rm
0, 1, 3
f (0x66)
A-2
0-2
(0x72)
Possible
AIM ID
Modifiers
(m)
Code ID
(hex)
Symbology
AIM ID
Straight 2 of 5 Industrial
]S0
f (0x66)
TCIF Linked Code 39 (TLC39)
]L2
T (0x54)
Telepen
]Bm
t (0x54)
UPC-A
]E0
c (0x63)
UPC-A with Add-On
]E3
c (0x63)
UPC-A with Extended
Coupon Code
]E3
c (0x63)
]E0
E (0x45)
UPC-E with Add-On
]E3
E (0x45)
UPC-E1
]X0
E (0x45)
UPC-E
Note: “m” represents the AIM modifier character. Refer to International
Technical Specification, Symbology Identifiers, for AIM modifier character
details.
Prefix/Suffix entries for specific symbologies override the universal (All
Symbologies, 99) entry.
Refer to Data Editing beginning on page 5-1 and Data Formatting beginning on
page 6-1 for information about using Code ID and AIM ID.
A-3
ASCII Conversion Chart (Code Page 1252)
Note: This table applies to U.S. style keyboards. Certain characters may differ
depending on your Country Code/PC regional settings.
Non-Printable Characters
DEC HEX Character (Code)
DEC HEX Character (Code)
16
17
10
11
DATA LINK ESCAPE (DLE)
DEVICE CONTROL 1 (DC1)
18
19
20
12
13
14
DEVICE CONTROL 2 (DC2)
DEVICE CONTROL 3 (DC3)
DEVICE CONTROL 4 (DC4)
NULL
START OF HEADING
(SOH)
START OF TEXT (STX)
END OF TEXT (ETX)
END OF TRANSMISSION
(EOT)
END OF QUERY (ENQ)
21
15
ACKNOWLEDGE (ACK)
BEEP (BEL)
22
23
16
17
10
11
12
BACKSPACE (BS)
HORIZONTAL TAB (HT)
LINE FEED (LF)
VERTICAL TAB (VT)
FF (FORM FEED)
24
25
26
27
28
18
19
1A
1B
1C
13
CR (CARRIAGE RETURN) 29
1D
14
SO (SHIFT OUT)
30
1E
15
SI (SHIFT IN)
31
1F
NEGATIVE ACKNOWLEDGEMENT (NAK)
SYNCHRONIZE (SYN)
END OF TRANSMISSION
BLOCK (ETB)
CANCEL (CAN)
END OF MEDIUM (EM)
SUBSTITUTE (SUB)
ESCAPE (ESC)
FILE SEPARATOR (FS)
RIGHT ARROW
GROUP SEPARATOR (GS)
LEFT ARROW
RECORD SEPARATOR (RS)
UP ARROW
UNIT SEPARATOR (US)
DOWN ARROW
Printable Characters
DEC
HEX
32
33
34
35
36
37
38
39
20
21
22
23
24
25
26
27
A-4
Character

DEC
HEX
64
65
66
67
68
69
70
71
40
41
42
43
44
45
46
47
Character
DEC
96
97
98
99
100
101
102
103
HEX
60
61
62
63
64
65
66
67
Character
Printable Characters (Continued)
DEC
HEX
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
Character
DEC
HEX
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
Character
DEC
HEX
Character
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F

Extended ASCII Characters
DEC HEX
128
129
130
131
132
133
134
135
136
137
138
139
80
81
82
83
84
85
86
87
88
89
8A
8B
Character
€€
‚
ƒ
„
…
†
‡
ˆ
‰
Š
‹
DEC HEX
171
172
173
174
175
176
177
178
179
180
181
182
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
Character
«
¬
®
¯
°
±
²
³
´
µ
¶
DEC HEX
214
215
216
217
218
219
220
221
222
223
224
225
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF
E0
E1
Character
Ö
×
Ø
Ù
Ú
Û
Ü
Ý
Þ
ß
à
á
A-5
Extended ASCII Characters (Continued)
DEC HEX
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
Character
Œ
Ž
‘
’
“
”
•
–
—
˜
™
š
›
œ
ž
Ÿ
¡
¢
£
¤
¥
¦
§
¨
©
ª
DEC HEX
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5
Character
·
¸
¹
º
»
¼
½
¾
¿
À
Á
Â
Ã
Ä
Å
Æ
Ç
È
É
Ê
Ë
Ì
Í
Î
Ï
Ð
Ñ
Ò
Ó
Ô
Õ
DEC HEX
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
Character
E2
E3
E4
E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
EF
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
â
ã
ä
å
æ
ç
è
é
ê
ë
ì
í
î
ï
ð
ñ
ò
ó
ô
õ
ö
÷
ø
ù
ú
û
ü
ý
þ
ÿ
Code Page Mapping of Printed Barcodes
Code pages define the mapping of character codes to characters. If the data
received does not display with the proper characters, it may be because the
barcode being scanned was created using a code page that is different from
A-6
the one the host program is expecting. If this is the case, select the code page
with which the barcodes were created. The data characters should then appear
properly.
Note: The Code Page option is available for Code 39, Code 93, and Code 128.
Code Page
Standard
Description
CP ISO646
2 (Default)
ISO 2022
CP Binary
51
ISO 8859 1 51
Western European Replacement
Characters
82
ISO 2022 11 Swe
Swedish Replacement Characters
83
ISO 2022 69 Fra
French/Belgium Replacement
Characters
81
ISO 2022 25 Fra
French/Belgium Replacement
Characters
Automatic National Replacement
Characters
84
ISO 2022 11 Ger
German Replacement Characters
85
ISO 2022 11 Ita
Italian Replacement Characters
86
ISO 2022 11 Swi
Swiss Replacement Characters
87
ISO 2022 11 UK
British Replacement Characters
88
ISO 2022 11 Dan
Danish Replacement Characters
89
ISO 2022 11 Nor
Norwegian Replacement Characters
90
ISO 2022 11 Spa
Spanish Replacement Characters
91
ISO 2022 85
Spanish Replacement Characters
92
ISO 2022 16
Portuguese Replacement Characters
93
ISO 2022 84
Portuguese Replacement Characters
94
ISO 2022 60
Norwegian Replacement Characters
A-7
A-8
Sample Symbols
UPC-A
0 123456 7890
Code 128
Code 128
Code 39
BC321
Code 93
123456-9$
Interleaved 2 of 5
1234567890
EAN-13
9 780330 290951
Codabar
A13579B
Straight 2 of 5 Industrial
123456
Sample Symbols
Matrix 2 of 5
6543210
GS1 DataBar
(01)00123456789012
Programming Chart
Programming Chart
Save
Discard
Reset
Note: If you make an error while scanning the letters or digits (before scanning
Save), scan Discard, scan the correct letters or digits, and Save again.
Honeywell Scanning & Mobility
9680 Old Bailes Road
Fort Mill, SC 29707
ft
15
VG1200-UG Rev (b)
10/11

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Author                          : Honeywell Scanning & Mobility
Create Date                     : 2011:09:15 10:16:43Z
Keywords                        : Honeywell, Voyager 1200g, Voyager 1202g
Modify Date                     : 2011:09:15 11:22:17-04:00
Subject                         : User’s Guide for Voyager 1200g and 2102g
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : FrameMaker 9.0
Metadata Date                   : 2011:09:15 11:22:17-04:00
Format                          : application/pdf
Title                           : Voyager 1200g/1202g User’s Guide
Creator                         : Honeywell Scanning & Mobility
Description                     : User’s Guide for Voyager 1200g and 2102g
Producer                        : Acrobat Distiller 9.4.5 (Windows)
Document ID                     : uuid:3ac2f2fa-2c0c-4ad7-ab8b-b380759b5e5d
Instance ID                     : uuid:e7687f02-28fe-4fc6-be7d-547a83fe1180
Page Mode                       : UseOutlines
Page Count                      : 288
EXIF Metadata provided by EXIF.tools
FCC ID Filing: LW5BT010M

Navigation menu