Honeywell EDA50011 Mobile Computer User Manual

Honeywell International Inc Mobile Computer Users Manual

Contents

Users Manual

ScanPalTM SeriesEnterprise Hybrid Device (EHD)EDA50-111EDA50-011 Quick Start GuideEDA50-SC-QS Rev B22/10Open the PackagePlease check if the following items included in the package:· ScanPalTM Enterprise Hybrid Device ;· Main battery (3.8V, lithium ion battery);· 10-watt power adapter;· Replaceable adapter plug;· USB charging cable;· Quick Start GuideRemarks:If you ordered accessories for the terminal, please make sure they are also included in the package; be sure to keep the original packages for ScanPalTM EDA50 to be returned for repairing when necessary.Note:End users should not arbitrarily replace the operating system with other operating systems. To update operating system installed on your device, you need to get license from the OS vendors.EDA50-111/EDA50-011 belongs to ScanPalTM SeriesFront PanelPower IndicatorScan IndicatorDisplayFunction KeyHome KeyReturn KeyRear PanelCameraScan EngineSpeakerBattery Cover Safety LockBattery Cover BuckleBattery Cover Safety ButtonBattery Cover Buckle HandleBattery CoverString BuckleLeft Side ViewThe BottomRight Side ViewPower Button Volume UpReset Button Volume DownScan ButtonCharging Contact USB CoverScan ButtonInstall the Main BatteryReplace the battery with wrong models may cause explosion. Please make sure to use the battery in accordance with local regulations.Please recycle the battery when possible.Do not dispose it as household wastePlease ensure all kits are dry when connect the mobile device or battery to external devices.Damages caused by connecting wet kits are not covered by the warranty.1.   Press down the battery cover safety button to move the battery cover safety lock to the unlock position at right;2.   Open the battery cover with the battery cover buckle handle ;3.  Insert the battery (Insert the non-connector side first, then press the battery down to establish connection between the battery and the phone)4.  Press down the battery cover (Insert the non-connector side first, then press the battery cover down)5.   Press down the battery cover safety button to move the battery cover safety lock to the lock position at leftRemarks:Refer to the illustrated installation steps on the following page.ScanPalTM EDA50 comes with a battery in a separate package. Please follow the steps below to install the battery.Charging / SyncSynchronous CommunicationOpen the USB cover at the bottom of ScanPalTM EDA50Connect ScanPalTM EDA50 to the computer with USB charging cableUSB CoverUSB charging cable
Charging / SyncCharging1.   Open the USB cover at the bottom of ScanPalTM EDA50;2.  Connect ScanPalTM EDA50 to the power adapter with USB charging cable;3.  Make sure the replaceable adapter plug  plugged into the power adapter;4.  Connect the power adapter to the wall plug and start charging for ScanPalTM EDA50.Remarks:It's recommended to use Honeywell's peripherals, batteries, USB charging cables and power adapters.Damages caused by using non-Honeywell peripherals, batteries, USB charging cables or power adapters are not covered by the warranty.Warnings:Please make sure all kits are dry when use the terminal and battery with other accessories.Damages caused by using wet kits may not be covered by the warranty.Get ScanPalTM EDA50 charged  for at least 4 hours before using it, subject to your battery models.Using the terminal while charging will significantly extend the time required for fully charged.Replaceable adapter plugPower adapterUSB charging cableUSB CoverSuspend / Wake Up the TerminalSuspend / Wake Up the TerminalPress the power button and then release (less than 2 seconds)To wake up the device from sleep mode, press the power button and then release (less than 2 seconds)RebootWhen something is wrong with the OS,  press the reset button and then release to restart ScanPalTM EDA50ScanPalTM EDA50 Power IndicatorThe status of power indicators in non-charging and charging process are illustrated  as below:Non- charging processOff Battery power is normalFlashing orange Battery power is lowCharging processConstant green Charging completeFlashing green During charging process,  and the charging is about to be completedOrange During charging process, and the battery power is still lowFlashing red Battery is abnormalInstall memory card1.  Power off;2.  Press down the battery cover safety button to move the lock to the unlock position at right;3.  Open the battery cover with the battery cover buckle handle ;4.  Pull out the battery (First open the battery connector side, then pull out the battery)5.  Insert the MicroSD card to SD card slot until it clicks;6.  Insert the battery (Insert the non-connector side first, then press the battery down to establish connection between the battery and the phone);7.  Press down the battery cover (Insert the non-connector side first, then press the battery cover down);8.  Press down the battery cover safety button to move the battery cover safety lock to the lock position at left;9.  Power onID CardInstall SIM Card1.  Power off;2.  Press down the battery cover safety button to move the lock to the unlock position at right;3.   Open the battery cover with the battery cover buckle handle ;4.  Pull out the battery (First open the battery connector side, then pull out the battery)5.  Insert the SIM card to SIM card slot until it clicks;6.  Insert the battery (Insert the non-connector side first, then press the battery down to establish connection between the battery and the phone);7.  Press down the battery cover (Insert the non-connector side first, then press the battery cover down);8.  Press down the battery cover safety button to move the battery cover safety lock to the lock position at left;9.  Power onNote: only EDA50-111 delivers this featureSIM CardUse Scan Engine Align the aiming beam with the barcodes, and adjust the angle between the beam and the barcodes to get the best results. The recommended range from the terminal to the barcodes is 4" to 10" (10cm to 25cm)1.  Click the demo application on the interface,  and then select Scan demo program;2.  Click Scan on the screen or press the Scan Button;3.  Align ScanPalTM EDA50 with the barcodes;4.  Adjust the aiming beam: in order to obtain the best performance, avoid scanning in a slight angle and slowly move the beam on the barcodes by scanning the reflection of the barcodes;5.  The terminal will beep when the barcodes are successfully decoded,  which means the information included in the barcode has been obtained by the terminalScan EngineAiming BeamThe aiming beam gets narrower when the terminal gets closer to the barcodes, while it gets wider when the terminal gets farther from the barcodes.The smaller the barcodes, the closer the aiming beams should get to the barcodesThe bigger the barcodes, the father the aiming beams should get to the barcodesBeam positions when scan 2D imagesTechnical SupportFor information about technical support, after-sales service and maintenance, please visit www.honeywellaidc.com .User DocumentsFor the local version of this article, please visit www.honeywellaidc.com .PatentsFor information on patents, please refer to www.honeywellaidc.com/patents.WarrantyPlease log into www.honeywellaidc.com/warranty_information  for warranty information on your product.DisclaimerHoneywell International Inc. reserves the rights to modify the specifications and other information mentioned above without prior notification. Readers should consult Honeywell International Inc. to make sure if any changes made any time they read this article.The information in this article does not represent any commitments of Honeywell International Inc.Honeywell International Inc. is not responsible for direct or indirect loss caused by any technical or editing errors or omissions contained in this article.The proprietary information contained in this article is protected by copyright.All rights reserved.Without prior written consent from Honeywell International Inc., any form of photocopy, copy or translation into other languages for any part of this article is not allowed.All Rights Reserved by Honeywell International Inc. Website: www.honeywellaidc.com

Navigation menu