Installation Instructions
CT62A provides single-line break.
CT62B provides double-line break.
Temperature Range: 10 to 25° C [50 to 80° F]
Electrical Ratings: 60 Hz noninductive
22A at 120-240 Vac; 19A at 277 Vac
Your new Honeywell CT62 Electric Heating Thermostat provides line voltage control of a radiant cable, electric baseboard,
and resistive-rated fan forced heaters within the ratings listed above.
Your Honeywell Thermostat
Do-It-Yourself models
PREPARATION
1
Proper installation of your Honeywell thermostat will
occur if you follow these instructions STEP-BY-
STEP. It is recommended that as you read, understand
and complete each step, you check it off with pencil or
pen.
ü
Make certain that your heating system is working,
especially if it has been inoperative for a length of
time. If the system does not work, contact your local
electrician for assistance.
Check thermostat sullability for your home's system
by reviewing the ratings listed above.
°C
30
20
10
2
4
1
7
3
331
1
1
11
[48]
[54]
[83]
[39] [13]
[19]
[13]
[73]
[111]
8
8
442
8
4
22
2
3
1
M5795A
THERMOSTAT MOUNTING
DIMENSIONS
2
FRONT VIEW SIDE VIEW
Carefully unpack your new thermostat. To avoid
damage to the sensing element, do NOT remove the
thermostat cover until wiring has been completed.
Save packages of screws, instructions, receipt and
proof-of-purchase.
Remove cover of old thermostat- cover normally
snaps off when pulled firmly from the bottom. If it
resists, check for a screw that locks the cover.
Loosen screws holding thermostat base to outlet box
and lift away.
Disconnect wires from old thermostat. As you
disconnect each wire, tape the end and label II with
the letter of the terminal designation to make reconnection
to new thermostat easier.
Check the old insulation for cracks, nicks or fraying,
and apply high quality plastic tape where necessary
for adequate insulation.
Retain the old thermostat for referance purposes
and until your new thermostat is functioning
smoothly.
Begin by tuming off power to the heating circuli at
the main service panel.
Line Voltage Electric Heat Thermostats
CT62A,B
REMOVE OLD THERMOSTAT
3
WARNING
08/98 Printed in Mexico ©Honeywell Inc. Form Number 95C-10866B
Votre nouveau thermostat Honeywell CT62 pour chauffage électrique assure la régulation tension secteur de câbles
chauffants, de plinthes électriques et d'appareils de chauffage à air forcé résistils, dans les limiles des capacités indiquées
ci-dessus.
Directives d'installations
Le CT62A est un thermostat à simple rupture de courant.
Le CT62B est un thermostat à double rupture de courant.
Gamme de température: 10 à 25° C [50 à 80° F]
Caractéristiques électriques nominales: 60 Hz, non inductif
22 Aà 120.240 V c.a.; 19Aà 277 V c.a.
Modèles à installer soi-même
Votre thermostat Honeywell
Le thermostat Honeywell sera bien installé si les
directives ci-dessous sont suivies ÉTAPE PAR
ÉTAPE. Nous vous recommandons de cocher chaque
étape au crayon ou au stylo à mesure qu'elle est lue,
comprise et exécutée.
Relire les caractéristiques nominales indiquées ci-
dessous pour s'assurer que le thermostat convient
au système.
S'assurer que le système de chauffage fonctionne
correctement. tout spécialement s'il n'a pas
tonctionné pendant une période prolongée. Si le système
ne fonctionne pas, communiquer avec un électricien de
votre localilé pour obtenir de l'aide.
1
2
PRÉPARATION
ENCOMBREMENT DU THERMOSTAT
Déballer soigneusement le nouveau thermostat.
Pour éviler d'endommager l'élément sensible, ne
pas retirer le couvercle du thermostat avant d'avoir
effectué le raccordement.
Conserver les paquets de vis, les directives, le reçu
et la preuve d'achat.
3RETRAIT DE L’ANCIEN THERMOSTAT
MISE EN GARDE
Retirer le couvercle de l'ancien thermostat. Le
couvercle devrait normalement se décrocher
lorsqu'on le tire fermement vers le bas. S'il résiste, vérifier
si une vis ne bloque pas le couvercle en place.
Dévisser les vis qui retiennent la base du thermostat
à la boite de jonction et retirer la base.
Débrancher les fils de l'ancien thermostat. À mesure
que les fils sont débranchés, apposer un ruban à
son extrémité et inscrire la lettre de la bome auquel il est
relié afin de facililer le raccordement au nouveau thermostat.
S'assurer que la gaine des fils n'est pas craquée,
entaillée ou usée, et appliquer au basoin du ruban
de plastique de bonne qualité pour assurer une bonne
isolation.
Conserver l’ancien thermostat à titre de référence
jusqu'à ce le nouveau thermostat fonctionne comme
ilsedoil.
Commencer par couper le courant du circuit de
chauffage au panneau de selVice principal.
°C
30
20
10
2
4
1
7
3
331
1
1
11
[48]
[54]
[83]
[39] [13]
[19]
[13]
[73]
[111]
8
8
442
8
4
22
2
3
1
M5795A
VUE FRONTALE VUE LATÉRALE
95C-10866B
08/98 Imprimé au Mexico © Honeywell Inc. 1998 Publication n°
Thermostats tension secteur pour chauffage électrique
CT62A,B
Secure the thermostat to the box with the two
captive mounting screws provided.
Replace thermostat cover.
Set Dial to desired room temperature
Begin with setting indicator at 20° C [70° F] on
the scale.
WIRE AND MOUNT NEW THERMOSTAT CHECK OUT THERMOSTAT
45
Turn the temperature setting dial to 20° C. [70° F]
This will prevent accidental damage to the dial
stop during mounting.
Remove thermostat cover by grasping the top and
bottom ends with fingers, and pulling outward.
Connect wires to the thermostat as shown in the
applicable wiring diagram. Push the wires into the
outlet box, and insert the thermostat into the box for
mounting by pushing against top and bottom of the
thermostat base.
IMPORTANT: Do not press on dial indicator knob.
IMPORTANT: Rough handling or strong pressure can
damage control knob or sensing element, and change
calibration.
3
3
1
1
244
L2
L2
T2
L1
L1
(HOT)
L1
T1 T1
CT62B CT62A
TO
ELECTRIC
HEATER ELECTRIC
HEATER
20
°C
M8422
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED
BREAKS ON POSITIVE OFF
EXPOSED UNUSED LEADWIRES TO BE PRQPERL Y INSULATED
THERMALLY ACTIVATED-BREAKS ON TEMPERATURE
RISE. MAKES ON TEMPERATURE FALL
CAUTION:
SPECIAL SERVICE CO/ALR SOLDERLESS CONNECTORS MUST
BE USED WHEN CONNECTING WITH ALUMINUM CONDUCTORS;
OTHERWISE, A FIRE HAZARD CAN RESULT. M8420
1
2
3
4
95C-10866B 2
Turn on the power to the heating system.
Turn setting dial all the way clockwise ; listen
for click sound as switch makes contact. Electric
heater should begin operation.
Turn dial all the way counterclockwise ; listen
for click sound as swich breaks contact. Electric
heater should shut off.
SETTING THERMOSTAT
6
If this setting is not satisfactory after at least two
hours of operation, turn setting indicator upscale to
raise the temperature, or downscale to lower the tempera-
ture. Move indicator only a degree each time.
VÉRIFICATION DU THERMOSTAT
45
95C-10866B 2
CÂBLAGE ET MONTAGE DU
NOUVEAU THERMOSTAT
Mettre le bouton de réglage de la température à
20° C [70° F]. On évitera ainsi d'endommager la
butée d'arrêt du cadran pendant l'instailation.
Remettre le couvercle en place.
Retirez le couvercle du thermostat en le saisissant
par les côtés inférieurs et en le faisant basculer vers
l’extérieur.
Raccorder les fils au thermostat comme l'indique le
schéma de raccordement qui s'applique à votre
modèle. Repousser les fils dans la boîte de jonction et
insérer le thermostat dans la boîte en appuyant sur la base
du thermostat par le haut et le bas.
Fixer le thermostat à la boîte de jonction au moyen
des deux vis imperdables fournies.
Régler le cadran à la température ambiante désirée.
IMPORTANT :
IMPORTANT:
Ne pas appuyer sur le bouton du cadran de
réglage.
Une manipulation trop brusque ou une
pression trop forte peuvent endommager le bouton de
réglage ou l'élément sensible et altérer l'étalonnage.
3
3
1
1
244
L2
L2
T2
L1
L1
(HOT)
L1
T1 T1
CT62B CT62A
VERS
L’APPAREIL
DE CHAUFFAGE
ÉLECTRIQUE
APPAREIL
DE CHAUFFAGE
ÉLECTRIQUE
ALIMENTATION, FOURNIR, AU BESOIN, UN DISPOSITIF DE
COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES
RUPTURE SUR COUPUAE DE COURANT.
LES FILS CONDUCTEURS NON UTILISÉS ET EXPOSÉS
DOIVENT ËTRE CORRECTEMENT ISOLÉS.
DÉCLENCHÉ PAR LA CHALEUR. RUPTURE SUR
HAUSSE DE TEMPÉRATURE; FERMETURE SUR
BAISSE DE TEMPÉRATURE.
AVERTISSEMENT:
UTILISER DES CONNECTEURS SANS SOUDURE POUR SERVICE
SPÉCIAL CO/AlR LORSQUE LE THERMOSTAT EST RACCORDÉ
À DES CONDUCTEURS EN ALUMINIUM AFIN D'ÉVITER
LES RISQUES D'INCENDIE.MF8409
20
°C
M8422
Rétablir le courant à l'appareil de chauffage.
Faire tourner le cadran de réglage jusqu'au bout
dans le sens horaire ; écouter pour entendre
le déclic qui se produi!lorsque le contact se referme.
L'appareil de chauffage électrique devrai! se mettre ne
marche.
Faire tourner le cadran de réglege jusqu'au bout
dans le sens antihoraire ; écouter pour
entendre le déclic qui se produit lorsque le contact s'ouvre.
L'appareil de chauffage électrique devrait cesser de
fonctionner.
6
RÉGLAGE DU THERMOSTAT
Commencer par régler le thermostat à 20 C [70 F].
Si ce réglage n’est pas satisfaisant après au moins
deux heures de fonctonnement, tourner le cadran
vers le haut de l’echelle pour augmenter la tempèrature ou
vers le bas de l’èchelle pour la diminuer. Déplacer
l’indicateur d’un degre à la fois seulement.
1
2
3
4
2
4
2
2
2
0
1
8
1
6
1
4
1
2
1
0
7
8
Your Honeywell thermostat requires little or no attention. Most problems can generally be traced to the following:
TROUBLESHOOTING
No heat. Make sure power is on at
main service panel. Turn
the temperature setting diale
fully ciockwise .
Improper connections to
thermostat.
Other.
Turn temperature setting
dial fully
counterclockwise .
Thermostat affected by
drafts or radiant heat.
Thermometer is out of
calibration.
Heater never turns
off.
Thermostat setting
and thermometer
reading disagree.
Heater should start to warm up within two minutes. If not,
contact qualified electrician to check thermostat and heater.
With power to circuit OFF, tighten all wiring connections. Repair
any frayed or broken wires.
Contact a qualified electrician for assistance.
Heater should start to cool within minutes. If not, turn off power
at the main service panel, and contact qualified electrician.
Contact electrician to change the location. The thermostat
should be about 5 ft [1.5m] above the floor and on an inside
wall.
Recalibrate. See step 8.
Symptom Checkout Actton
The CT62 Thermostats are calibrated at the factory using
precise instruments under closely controlled conditions.
Recalibration should not be necessary. Allow the thermo-
stat to operate for several hours before checking the
calibration. The CT62 Thermostat vapor-filled dual
diaphragm sensing element is affected by barometric
pressure and altitude. Temperature deviations of 10 F
[0.50 C] are normal. If the thermostat is mounted in a
suitable location and still appears out of calibration, check
calibration as follows:
Turn the setting knob clockwise until the switch
makes (click sound). The heating equipment will
come on.
No recalibration is necessary If the thermostat switch
makes with the thermostat setting at the same
temperature as indicated on the thermometer.
If the thermostat setting differs from the thermom-
eter, record the temperature difference and
recalibrate as instructed in the Recalibration Procedure
section.
Note the temperature difference between the
temperature setting and the thermometer.
Remove the thermostat cover.
Rotate set point knob clockwise until you hear
switch click.
Hold the set point knob firmly and rotate the set
point scale ring counterclockwise until the
12 o'clock position of the ring agrees with the' cover
thermometer.
Recalibration Procedure
CALIBRATION
Check Calibration
The heat from your hand will affect the diaphragm
sensor. Replace thermostat cover, wait 5 minutes
and recheck calibration.
THERMOSTAT
BASE
SETTING KNOB
AT 12 O’CLOCK
POSITION
SCALE RING
SETTING KNOB
M5796
395C-10866B
Assurez-vous que l'alimentation est
rétablie au panneau principal.
Toumer le cadren de réglage de la
temperature dans le sens horaire
jusqu'au bout
Raccordements du thermostat mal
effectués.
Des courants d'air ou autre chaleur
rayonnante ont un effet sur le
thermostat.
Le thermostat Honeywell exige peu ou pes d'attention. La plupart des problèmes relèvent de ce qui suit :
Autre.
Le thermomètre est mal étalonné.
Toumer la cadran de réglage de la
température dans le sens
antihoraire jusqu'au bout.
Symptômes
Absence de chaleur
L'appareil de chauffage
fonctionne sans cesse
Le réglage du thermostat
et la température au
thermomètre ne
correspondent pas.
Vérification
Action
L'appareil de chauffage devrait commencer à se
réchauffer dans les daux minutes qui suivent. Si ce
n’est pes le cas, communiquer avec un électricien
qualifié pour taire vérifier le thermostat et l'appareil de
chauffage.
Une fois coupée l'alimentation électrique au circuit,
resserrez toutes les connexions. Faites basculer le
couvercle vers le bas jusqu'à ce qu'il se referme.
Communiquer avec un électricien qualifié pour
obtenir de l'aide.
L'appareil de chauffage devrait commencer à se
refroidir dans les deux minutes qui suivent. Si ce
n'est pes le cas, couper l'alimentation électrique au
panneau principal et communiquer avec un
électricien qualifié.
Communiquer avec un électricien afin de faire
changer l'emplacement du thermostat. Le thermostat
devrait être situé à environ 1,5 m [5 pl] au-dessus du
niveau du sol, sur un mur intérieur.
Réétalonner le thermostat. Voir l'étape 8.
VÉRIFICATION
7
ÉTALONNAGE
Les thermostats CT62 sont étalonnés à l'usine au moyen
d'instrument précis et dans des conditions soigneusement
contrôlées. Il ne devrait donc pas être nécesseire de les
réétalonner. Laisser le thennostat fonctionner pendant
quelques heures avant de vérifier l'étalonnage. L'élément
sensible des CT62 à double membrane remplie de vapeur
réagit à la pression barométrique et à l'altitude. Des écarts
de température de 0,5 °C [1°F] sont normaux. Si le
thermostat est installé dans un emplacement qui convient
et qu'il semble toujours être mal étalonné, vérifier
l'étalonnage comme suit :
Vértftcatlon de l'étalonnage :
Le système de chauffage se meltra en marche.
Il n'est pas nécassaire de réétalonner le thermostat
si le le contact du thermostat se referme et que la
Si le point de consigne du thermostat diffère du
relevé au thermomètre, prendre en note la
Réétalonnage :
Noter la différence entre la température de conaigne
et la température du thermomètre.
Retirer le couvercle du thermostat.
Faire tourner le bouton de réglage du point de
consigne dans le sens horaire jusqu'à ce
Tenir le bouton fermement et faire tourner
l'anneau gradué dans le sens antihoraire
8
différence et ré-étalonnez le thermostat comme suit
température de consigne est la méme que celle du
thermomètre.
jusqu'à que la position 12 heures corresponde au
thermomètre du couvercle.
que le contact fasse entendre un déclic.
La chaleur dégagée par les mains fait réagir la
membrane de détection de la température.
Remettre le couvercle en place, et ettendre 5 minutes
avant de vérifier de nouveau l'étalonnege.
2
4
2
2
2
0
1
8
1
6
1
4
1
2
1
0
SUPPORT DU
THERMOSTAT
BOUTON DE
RÉGLAGE À LA
POSITION
12 HEURES
ANNEAU GRADUÉ
BOUTON
DE RÉGLAGE
M5796
395C-10866B
Honeywell warrants this product to be free from defects in the workmanship or materials, under normal use and service, for a
period of one (1) year from the date of purchase by the consumer, If, at any time during the warranty period, the product is
defective or malfunctions, Honeywell shall repair or replace ii (at Honeywell's option) within a reasonable period of time,
If the product is defective,
(i) retum it, with a bill of sale or other dated proof of purchase, to the hardware or home center store from which you
purchased it, or
(ii) package it carefully, along with proof of purchase (including date of purchase) and a short description of the malfunction,
and mail it, postage prepaid, to the following address:
Honeywell lnc, RG Department in Canada: Honeywell Consumer Products
1050 BerKshire Lane 510 Bronte St. S.
Plymouth, MN 55441-4437 Milton, ON L9T 2 X 6
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if ij is shown by Honeywell that the
defect of malfunction was caused by damage which occurred while the product was in the possession of a consumer.
Honeywell's sole responsibilijy shall be to repair or replace the product within the terms stated above.
,
OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion of incidental or consequential dem
ages, so this limi ation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF
ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICU-
LAR PURPOSE, IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not allow
limitations on how long an implied warranty lasts, so the above limitation may not apply to your.
This warranty gives you specnic legal rights, and you may have other rights which vary from state to state.
If you have any questions concerning this warranty, please write our Customer Assistance Center, Honeywell Inc.,
P.O. Box 524, Minneapolis, MN 55440-0524 or call 1-800-468-1502, Monday-Friday, 7:00 a.m.-5:30 p.m. Central time.
In Canada write to Honeywell Consumer Products, 510 Bronte Sf. S., Milton, ON L 9 T 2 X 6.
HONEYWELL SHALL
NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL
DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED-
t
Limited One-Year Warranty
Garantie Iimitée d'un an
Si le produit est défectueux,
(i) le retourner, accompagné d'une preuve d'achat indiquant la date d'achat, au détaillant ou à l'entrepreneur auprès de
qui il a été acheté, ou
(ii) l'emballer avec soin, accompagné d'une preuve d'achat indiquant la date d'achat et d'une brève description du
mauvais fonctionnement, et l'envoyer par la poste, port payé, à l'adresse suivante :
Honeywell inc. Au Canada: Produits à la consommation,
R G Department Honeywell Limitée
1050 Berkshire Lane 510 Bronte St. S.
Plymouth, MN 55441-4437 Milton (Ontario) L9T 2X6
La présente garantie ne couvre pas les frais de retrait ou de réinstallation. La présente garantie ne s'appliquera pas s'il est
démontré que la défectuosité ou le mauvais fonctionnement est dû à un endommagement du produit alors que le
consommateur l'avait en sa possession.
La responsabilité de Honeywell se limite à réparer ou à remplacer le produit conformément aux modalités susmentionnées.
HONEYWELL N'EST EN AUCUN CAS RESPONSABLE DES PERTES OU DOMMAGES, Y COMPRIS LES DOMMAGES
INDIRECTS OU ACCESSOIRES DÉCOULANT DIRECTEMENT OU INDIRECTEMENT D'UNE VIOLATION
QUELCONQUE D'UNE GARANTIE, EXPRESSE OU TACITE, APPLICABLE AU PRÉSENT PRODUIT. Certaines
provinces ne permettent pas l'exclusion ou la restriction des dommages indirects et, par conséquent, la présente restriction
peut ne pas s'appliquer.
LA PRÉSENTE GARANTIE TIENT LIEU DE TOUTES LES AUTRES GARANTIES, EXPRESSES OU TACITES, ET LES
GARANTIES DE VALEUR MARCHANDE ET DE CONFORMITÉ À UNE FIN PARTICULIÈRE SONT PAR LES
PRÉSENTES EXCLUES APRÈS LA PÉRIODE D'UN AN DE LA PRÉSENTE GARANTIE. Certains États ne permettent
pas de limiter la durée des garanties tacites et, par conséquent, la présente limitation peut ne pas s'appliquer.
La présente garantie donne au consommateur des droits légaux spécifiques et peut-être certains autres droits qui peuvent
varier d'une province à l'autre.
Honeywell garantit ce produit contre tout vice de fabrication ou de matière dans la mesure où il en est fait une utilisation et
un entretien convenables, et ce, pour une période d'un (1) an à compter de la date d'achat. En cas de défectuosité ou de
mauvais fonctionnement pendant la période de garantie, Honeywell remplacera ou réparera le produit (au gré de Honeywell)
dans un délai raisonnable.
Pour toute question relative à la présente garantie, écrire à : Customer Assistance Center, Honeyweillnc., P.O. Box
524, Minneapolis, MN 55440-0524, ou composer le 1-800-468-1502, du lundi au vendredi, de7hà17h30,heure du
Centre. Au Canada, écrire à : Produits à la consommation, Honeywell Limitée, 510 Bronte St. S., Milton (Ontario)
L9T 2X6.

Navigation menu