Honeywell Ct8611 Users Manual 69 0816 PROGRAMMABLE HEAT PUMP THERMOSTAT
CT8611 to the manual 6c0c7e44-bef5-4118-bd5f-ba64fde26946
2015-01-23
: Honeywell Honeywell-Ct8611-Users-Manual-261441 honeywell-ct8611-users-manual-261441 honeywell pdf
Open the PDF directly: View PDF .
Page Count: 16
Download | |
Open PDF In Browser | View PDF |
CT8611 PROGRAMMABLE HEAT PUMP THERMOSTAT INSTALLATION MANUAL IMPORTANT: This thermostat may be programmed either before or after installation. Refer to Owner’s Guide, form 69-0398, for programming instructions. 12-93 • Form Number 69-0816 1 69-0816 Toll-free Customer Assistance For all questions concerning this thermostat, please read and follow the instructions. If additional assistance is needed, call Honeywell Customer Assistance toll-free at 1-800-468-1502, Monday-Friday, 7:00 a.m.-5:30 p.m. Central Time. Before you call, please have the following information available—thermostat model number and date code, kind of heating/cooling system (i.e., hot water, warm air, oil, gas, etc.), number of wires connected to the thermostat. NOTICE This equipment is a Class B digital apparatus, which complies with Canadian Radio Interference Regulations, CRC c. 1374. 2 1 PREPARATION Your new thermostat provides energy saving control for a 24 Vac multistage heat pump heating/ cooling system direct from the control transformer. The CT8611 includes SYSTEM and ENRG SAV LEDs located near the top of the thermostat face. The SYSTEM LED lights when the thermostat is signaling for heating or cooling. The ENRG SAV LED lights during the LEAVE and SLEEP periods. The CT8611 also includes AUX. HT. and EM. HT. LEDs near the bottom center of the subbase. The AUX. HT. LED lights whenever the thermostat is calling for operation of the backup or auxiliary heater. Backup (auxiliary) heat is more expensive to operate than the heat pump and typically is used only when the heat pump is unable to handle the heating load. The EM. HT. LED lights whenever the thermostat system switch is in the EM. HT. position. Heat and cool anticipation is fixed in all models; no adjustment is necessary. Cycle rates are adjustable for auxiliary heating stage. Any questions concerning your system’s compatibility with your thermostat may be directed to Honeywell Customer Assistance at their toll-free number, 1-800-468-1502. WARNING This device is designed to operate on low voltage (20 to 30 Vac). The application of higher voltage is dangerous and may cause electrical shock, fire or personal injury. WHEN INSTALLING THIS PRODUCT… 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the CT8611 Heat Pump Thermostat Wiring Guide, form 69-0817, to make sure the product is suitable for your application. 3. Allow thermostat to warm to room temperature before operating. 4. After installation is complete, check thermostat operation as provided in these instructions. 3 69-0816 TOOLS REQUIRED FOR INSTALLATION Assemble a flat blade screwdriver and other tools as needed (right). FLAT BLADE SCREWDRIVER Test to make certain that your heating and cooling systems are working properly. If either does not work, contact your local heating/air conditioning dealer. To avoid compressor damage, do not operate the cooling system if outdoor temperature is below 50° F [10° C]. HAND OR POWER DRILL WITH 3/16 INCH DRILL BIT, IF NEEDED TO DRILL HOLES IN WALL WIRE CUTTER/STRIPPER OR SHARP KNIFE, IF NEEDED TO STRIP WIRES TURN OFF POWER to the system at the heat pump and at the fuse/circuit breaker panel. Carefully unpack your new thermostat. Save instructions, proof of purchase from packaging and original receipt. MASKING TAPE, IF NEEDED TO LABEL WIRES AS THEY ARE DISCONNECTED FROM OLD THERMOSTAT SPIRIT LEVEL, IF NEEDED TO LEVEL THERMOSTAT FOR APPEARANCE 4 M849 2 REMOVE OLD THERMOSTAT Disconnect wires from old thermostat or sub base. Always label all wires as you disconnect them from your old thermostat. Use the CT8611 Wire Tags provided to label each wire with the appropriate terminal designation as you remove it. It is important to note the terminal designation when removing wires. Not all thermostats are wired by color code. Keep the wires from falling back into the wall by wrapping them around a pencil, as shown. WARNING If your old thermostat is attached to a junction box in the wall, it is likely that 120V are present. To prevent electrical shock hazard, do not proceed. Call a qualified electrician. CAUTION WIRES THROUGH WALL OPENING 1. Disconnect power supply to prevent electrical shock or equipment damage. 2. After wiring is complete, push excess wire back into the hole, and plug hole with nonhardening caulk, putty, or insulation to prevent drafts from affecting thermostat operation. M5136 Remove cover from old thermostat. If it doesn’t snap off when pulled firmly from the bottom, check for a screw that locks the cover. Loosen screws holding thermostat to subbase, wallplate or wall, and lift away. 5 69-0816 Do not discard your old thermostat until you have thoroughly checked out system operation with your new Honeywell CT8611 Heat Pump Thermostat installed. If your old thermostat contains mercury, do not dispose of it in the trash, see below. MERCURY SWITCH ANTICIPATOR SCALE RECYCLING THERMOSTAT If this thermostat is replacing a thermostat that contains mercury in a sealed tube, do not place your old thermostat in the trash. Contact your local waste management authority for instructions regarding recycling and the proper disposal of your old thermostat. If you have questions, call Honeywell Inc. at 1-800-468-1502. COILED BIMETAL ANTICIPATOR SETTING LEVER M3376 Typical location of a mercury switch in a thermostat. 6 3 MOUNT THERMOSTAT SUBBASE The subbase does not require leveling for proper operation; level it for appearance only. Thread wires through the center opening of the subbase. Then, mount the subbase using the two screws provided. Gently tighten the screws, level the top surface of the subbase and then securely tighten the screws. Remove thermostat from subbase (Fig. 1). Mount the subbase directly onto the wall with the screws included in the package. Use the subbase as a template, and with a pencil, mark the two mounting screw positions (Fig. 2). Use 3/16 in. bit to drill holes for anchors. Gently tap anchors into holes until they are flush with the wall surface. WALL WIRES THROUGH WALL OPENING WALL ANCHORS (2) MOUNTING HOLES . HT HEAT OFF COOL FAN ON AUTO AUX. HEAT MOUNTING SCREWS (2) M9073 SUBBASE Fig. 1—Removing thermostat from base. M5175 Fig. 2—Mounting subbase on wall. 7 69-0816 4 WIRE THERMOSTAT TERMINALS FOR STRAIGHT INSERTION – STRIP 5/16 in. [8 mm] NOTE: All wiring must comply with local codes and ordinances. If unsure about household wiring procedures, call Honeywell Customer Assistance with your questions Monday-Friday, 7:00 a.m.5:30 p.m., Central time, 1-800-468-1502. FOR WRAPAROUND – STRIP 7/16 in. [11 mm] RESTRICT WIRING TO THIS AREA Refer to the CT8611 Heat Pump Thermostat Wiring Guide, form 69-0817, and to the wire labels you applied when you removed the old thermostat. Match the letter from your old thermostat wire with the appropriate letter on your new thermostat. Follow any special instructions provided in the Wiring Guide. Wire only those terminals shown with lines connecting them. Some terminals on the thermostat may not be used. FRONT VIEW OF TERMINAL AREA WIRING TO BE BELOW THIS SURFACE For each wire, loosen the terminal screw, slip the wire beneath its matching terminal, and tighten the screw. The shape of the terminal barrier allows straight or conventional wraparound wiring connections. TOP SURFACE OF SUBBASE CROSS-SECTIONAL VIEW OF TERMINAL AREA M3062 Fig. 3—Keep wiring restricted to ribbed area surrounding terminals. NOTE: Keep all wiring restricted to ribbed area surrounding terminals (Fig. 3) to assure thermostat/subbase contact. 8 Figs. 4 and 5 illustrate typical hookups for the CT8611 heat pump thermostat. CT8611R CT8611R R C R O C O B P L B G Y1 W1 P E L E W2 DEFROST CONTROL COMPRESSOR CONTACTOR MONITOR 1 G Y1 W1 EM. HT. RELAY W2 AUX. HT. RELAY FAN C/O RELAY HEAT C/O RELAY COOL POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. MONITOR DEFROST CONTROL 1 1ST STAGE HEAT RELAY 1ST STAGE COOL RELAY AUX. HT. RELAY EM. HT. RELAY C/O RELAY HEAT FAN C/O RELAY COOL 1 L2 L2 L1 (HOT) L1 (HOT) 1 M9077 Fig. 4—Typical hook up of CT8611 with jumper intact. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M9076 Fig. 5—Typical hook up of CT8611 with jumper removed. 9 69-0816 5 COMPLETE INSTALLATION ADJUST CYCLE RATE 1st stage heating and 1st stage cooling cycle rates are factory-set for heat pumps. The heat pump compressor cycle rate cannot be adjusted. To customize the thermostat’s performance to different types of heating equipment, however, a cycle rate adjustment screw is provided on the back of the thermostat to control the auxiliary heat cycle rate. Correct setting of the screw will provide optimum savings, See Fig. 6. 1A NOTE: MOST APPLICATIONS DO NOT REQUIRE A CHANGE IN CYCLE RATE. The room air temperature normally varies slightly from the comfort temperature setting with the cycling of the heat pump or auxiliary heater. INSTALL BATTERIES Three AAA alkaline batteries are included with the thermostat to prevent program loss in case of power outage. Install batteries in back of thermostat as shown in Fig. 7. Without battery backup, the 1B NOT USED 1B IN OUT 1/2 TURN AUXILIARY HEAT CYCLE RATE 3 CPH 6 CPH SLOWER CYCLING FASTER CYCLING M3058 BATTERY PLACEMENT (NOTE CORRECT PLUS AND MINUS DIRECTION) M9075 Fig. 6—Cycle rate adjustment. 10 Fig. 7—Battery placement. program will remain for only about 20 seconds in the event of power loss. When batteries are first installed, the display will flash 1:00 PM and 32°. When the batteries are low, the display will flash REPL BAT. You have 2030 seconds to replace batteries after removing them from the thermostat. After 20-30 seconds, you will have to reprogram. REPL BAT indication will disappear when the thermostat is mounted back onto the powered subbase. If batteries are completely dead, the display will go blank when the thermostat is removed from the subbase. After replacing the battery in this case, reprogramming is necessary. MOUNT THE THERMOSTAT With system switch set to OFF, hang the thermostat on the tabs at the top of the subbase (Fig. 8A). Swing down and press on lower edge until thermostat snaps in place (Fig. 8B). Open cover and tighten the captive mounting screws (Fig. 8C). A. B. ENRG. SAVE SYSTEM PM MON MORNIMG ROOM HEAT ON FAN AUTO ON AUTO OFF COOL EM. HT HEAT EM. HEAT AUX. HEAT C. ENRG. SAVE SYSTEM PM ROOM HEAT ON MON MORNIMG TEMPERATURE PRESENT SETTING RUN PROGRAM PERIOD TIME SET PRESENT DAY/TIME DAY WAKE LEAVE HOLD TEMP SET HEAT/COOL SLEEP RETURN AHEAD WARMER BACK COOLER SKIP NEXT PERIOD CHANGE TO LAST PERIOD M9074 Fig. 8—Mounting the thermostat on subbase. 11 69-0816 SET DAY AND TIME Restore 24V power to the thermostat. When power is applied, the display will read 1:00 PM and indicate the room temperature. It will go off for a few seconds, then begin to flash on and off. Set the present day and time. SET Press PRESENT DAY/TIME Press DAY If the display will not come on: — check the mounting of the thermostat to the subbase. If loose or misaligned, remove thermostat and reinstall on the subbase, making sure it is firmly attached. — check to see that system power is on. — check voltage between R and C; it should be 20 to 30 Vac. . to set the current day. Each press of the DAY key advances the display one day. Press TIME AHEAD or BACK to set the current time. 12 6 CHECK THERMOSTAT OPERATION Heating should start and the fan should run (there may be a delay of 5-10 minutes before heat turns on). Press COOLER key until the setting is about 10° F [6° C] below room temperature. The heating equipment and fan should shut off. During checkout, the backup heat will come on immediately. During normal operation, the backup heat will come on after a delay. Backup (auxiliary) heat is more expensive to operate than the heat pump and typically is used only when the heat pump is unable to handle the load. CAUTION • Do not check the heating system operation by jumpering thermostat terminals at the primary control. This will damage the thermostat. • To avoid possible compressor damage, do not operate the cooling system if the outside temperature is below 50° F [10° C]. See compressor manufacturer’s instructions for further information. • During cold weather, some heat pumps will require that the crankcase heater be energized several hours before operating the heat pump. Refer to the manufacturer’s recommendations. CHECK EMERGENCY HEATING OPERATION Move the system switch to EM. HEAT and the fan switch to AUTO. Press WARMER key until the setting is about 10° F [6° C] above room temperature. Heating should start and the fan should run. CHECK COOLING OPERATION Move the system switch to COOL and the fan switch to AUTO. Press COOLER key until the setting is about 10° F [6° C] below room temperature. Cooling should start and the fan should run. Press WARMER key until the setting is about 10° F [6° C] above room temperature. The cooling equipment and fan should shut off. Restore the power to the system. CHECK HEATING OPERATION Move the system switch to HEAT and the fan switch to AUTO. Press WARMER key until the setting is about 10° F [6° C] above room temperature. 13 69-0816 • • • • on your furnace or air conditioner, it considers (1) air temperature, (2) the temperature of the wall and (3) when you want the comfort temperature established. During Adaptive Intelligent Recovery TM the thermostat increases the control temperature gradually and turns the equipment on and off several times to save energy by avoiding “overshooting” the comfort temperature. See the current control temperature anytime during recovery by pressing the PRESENT SETTING key. On some models, both the SYSTEM and ENERGY SAVING lights may be lit at the same time during recovery. This “smart” control learns from experience. Each day it checks how closely it “hit the target” and adjusts the recovery start time accordingly. It typically takes four to eight days after installation for this thermostat to adjust to the weather, life style, home construction and heating/cooling system. The thermostat calculates the LEAVE/RETURN recovery separately from the SLEEP/WAKE recovery. ABOUT ADAPTIVE INTELLIGENT RECOVERYTM People perceive temperature from a variety of sources, not only from the air in the room, but also from their surroundings—walls, windows and furnishings. Human beings feel differences in temperature as slight as two degrees Fahrenheit. Common household thermometers and standard thermostats sense only air temperature, which may or may not reflect how hot or cold the room actually feels to a human being. This thermostat reads the temperature of the wall as well as the air—and responds to temperature changes as little as one degree Fahrenheit—so room temperature is more likely to “feel right.” THE OPTIMUM COMFORT AND ENERGY SAVINGS SOLUTION This thermostat is actually a small but powerful computer. When calculating the exact time to turn System Operating in Comfort Mode AM REPL SET TEMPERATURE PT PM BAT SUN MON TUE WED THU FRI SAT COOL ON HEAT ON WAKE LEAVE RETURN SLEEP TEMPORARY UNOCCUIPIED AM REPL SET PT PM BAT SUN MON TUE WED THU FRI SAT COOL ON HEAT ON WAKE LEAVE RETURN SLEEP TEMPORARY UNOCCUIPIED Recovery Continues Recovery Begins AM REPL PM BAT System Operating in Energy Savings Mode AM REPL SET PT SUN MON TUE WED THU FRI SAT COOL ON HEAT ON WAKE LEAVE RETURN SLEEP TEMPORARY UNOCCUIPIED SET PT PM BAT SUN MON TUE WED THU FRI SAT COOL ON HEAT ON WAKE LEAVE RETURN SLEEP TEMPORARY UNOCCUIPIED ENERGY SAVINGS PERIOD RECOVERY FROM ENERGY SAVINGS COMFORT PERIOD TIME THE THERMOSTAT USES THE SAME SCHEME TO RETURN GRADUALLY TO LOWER COMFORT TEMPERATURE DURING THE COOLING SEASON. 14 M171 IF ADDITIONAL ASSISTANCE IS NEEDED, PLEASE CONTACT HONEYWELL CUSTOMER ASSISTANCE AT 1-800-468-1502, MONDAY-FRIDAY, 7:00 AM-5:30 PM, CENTRAL TIME. BEFORE YOU CALL, PLEASE HAVE THE FOLLOWING INFORMATION AVAILABLE: TYPE OF HEATING SYSTEM, IGNITION TYPE, WHETHER GAS OR ELECTRIC AIR CONDITIONING, MODEL NUMBER OF OLD THERMOSTAT, NUMBER OF WIRES, AND TERMINAL DESIGNATIONS USED. 15 69-0816 Home and Building Control Honeywell Inc. 1985 Douglas Drive North Golden Valley, Minnesota 55422 G.S. 12-93 Home and Building Control Honeywell Limited—Honeywell Limitée 740 Ellesmere Road Scarborough, Ontario M1P 2V9 16 ©Honeywell Inc. 1993 Printed in Tiawan Form Number 69-0816 Helping You Control Your World
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Extract, Assemble, Print high-res XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Create Date : 2001:04:11 15:15:17Z Creator Tool : Adobe PageMaker 6.5 Modify Date : 2007:05:07 15:46:38-05:00 Metadata Date : 2007:05:07 15:46:38-05:00 Format : application/pdf Description : Installation Instructions Creator : HBC Technical Communications Title : 69-0816 -CT8611 PROGRAMMABLE HEAT PUMP THERMOSTAT Keywords : Producer : Acrobat Distiller 4.05 for Macintosh Document ID : uuid:3352bf30-308d-4227-a5a7-4b05b732f475 Instance ID : uuid:919e3fe9-507a-4994-bf18-9ed2856e7ce0 Page Count : 16 Subject : Installation Instructions Author : HBC Technical CommunicationsEXIF Metadata provided by EXIF.tools