Honeywell R8182D Users Manual 68 0105 R8182D,E,F,H,J Combination Protectorelay And Hydronic Heating Controls
R8182D 68-0105
R8182H to the manual f27815b7-a7ac-4bb7-a330-336eaa678fc1
2015-01-23
: Honeywell Honeywell-R8182D-Users-Manual-261189 honeywell-r8182d-users-manual-261189 honeywell pdf
Open the PDF directly: View PDF .
Page Count: 20
Download | |
Open PDF In Browser | View PDF |
R8182D,E,F,H,J Combination Protectorelay™ and Hydronic Heating Controls PRODUCT DATA FEATURES • Depending on model, these single unit devices provide combinations of high limit, low limit, and circulator control. • All models use a 24V thermostat and C554A Cadmium Sulfide Flame Detector. • R8182D,E,H and J have auxiliary terminals ZC and ZR for circulator zone control. Additional zones require a separate 24V thermostat and R845 Relay. • All models have capability for zone control with zone valves. Each additional zone requires a separate 24V thermostat and a V8043 or V8044 Zone Valve. • Ideal for packaged boiler systems requiring compact, multipurpose controls. • R8182D,E,F mode • R8182H,J models mount on a 4 x 4 inch junction box, and have a 5 ft (1.5m) armored capillary for remote sensor location. • Aquastat® Controller section is field replaceable. • Oil burner circuit includes an improved safety shutoff in the event the burner fails to start. GENERAL • Flame failure during the running cycle results in a 45 second attempt to restart. If unsuccessful, safety shutoff occurs, requiring manual reset before burner can be restarted. The R8182 is a combination Protectorelay™ intermittent ignition oil burner primary and immersion type Aquastat® controller for oil-fired, hydronic heating systems. Contents General ............................................................................. 1 Features ........................................................................... 1 Specifications ................................................................... 2 Ordering Information ........................................................ 2 Installation ........................................................................ 5 Wiring ............................................................................... 7 Operation .......................................................................... 12 Startup and Checkout ....................................................... 14 ® U.S. Registered Trademark Copyright © 2002 Honeywell • All Rights Reserved 68-0105-2 R8182D,E,F,H,J COMBINATION PROTECTORELAY™ AND HYDRONIC HEATING CONTROLS SPECIFICATIONS IMPORTANT The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifications. Also, this product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed. TRADELINE® Models: TRADELINE® models are selected and packaged for ease of handling, ease of stocking, and maximum replacement value. TRADELINE® model specifications are the same as those of standard models except as noted below. TRADELINE® Models Available: R8182D Combination Protectorelay™ Primary Control and Aquastat® Controller. R8182H Combination Protectorelay™ Primary Control and Aquastat® Controller. Additional Features: • Well not included. To order wells or well adapters, refer to form 68-0040, Wells and Fittings for Temperature Controllers, for part numbers and descriptions. • Heat-conductive compound supplied for better bulb response in oversized well. • Field addable stops for Aquastat® Controller. • Conversion to R8182E or F. • TRADELINE® pack with special instructions. • Wire nut. Mounting Means: R8182D,E,F: Case clamps to horizontal immersion well installed through boiler wall. R8182H,J: Mounts on standard 4 x 4 inch junction box. Dimensions: Refer to Fig. 1 and 2. Table 1. Standard Models: Adjustable Control Range Model R8182Da R8182Ea R8182F R8182Ha Remote Bulb a R8182J Remote Bulb a Switching °F Differential °C °F °C High Limit, Spst 130 to 240 54 to 116 10 Fixed 6 Fixed High Limit/Circulator, Spdt 110 to 220 43 to 104 10 to 25 Adj 6 to 14 Adj High Limit, Spst 180 to 240 82 to 116 15 Fixed 8 Fixed High Limit, Spst 130 to 240 54 to 116 10 Fixed 6 Fixed Circulator, Spst 110 to 220 43 to 104 10 Fixed 6 Fixed High Limit, Spst 130 to 240 54 to 116 10 Fixed 6 Fixed Low Limit/Circulator, Spdt 110 to 220 43 to 104 10 to 25 Adj 6 to 14 Adj High Limit, Spst 180 to 240 82 to 116 15 Fixed 8 Fixed Auxiliary ZC and ZR terminals can be used to provide circulator zone control through an R845A Switching Relay. Electrical Ratings: Power Supply: 120 Vac, 60 Hz. Ignition: 360 VA in addition to motor load rating. Maximum Power Consumption: R8182D,E,H and J: 9W. R89182F: 5.5W. Burner Circulator Contact Rating: 4.4A full load; 26.4A locked rotor at 120 Vac. Safety Switch Timing: Approximately 45 seconds. Flame Detector Required: C554A Cadmium Sulfide Flame Detector (ordered separately). Thermostat Required: 24V, 2-wire thermostat such as the T87F. ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Home and Building Control Sales Office (check white pages of your phone directory). 2. Home and Building Control Customer Relations Honeywell, 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 68-0105—2 2 R8182D,E,F,H,J COMBINATION PROTECTORELAY™ AND HYDRONIC HEATING CONTROLS KNOCKOUTS FOR 1/2 IN. (13 MM) CONDUIT (5) KNOCKOUTS FOR 1/2 IN. (13 MM) CONDUIT (5) 2-7/16 (62) 1-5/16 (33) 3-3/8 (86) 1/2 (13) 1 1 7/8 (22) VERTICAL MOUNT ONLY 7-1/8 (181) 3-7/16 (87) 7-1/8 (181) 3-9/16 (91) 3/16 (5) HORIZONTIAL MOUNT ONLY 5-1/4 (133) 1 3-1/4 (83) VERTICAL MOUNT SHOWN. 3-7/16 (87) 5-1/4 (133) M4517 1 SIDE MOUNTED HINGE SHOWN. Fig. 1. R8182D,E,F installation dimensions in in. (mm). M4518 Fig. 2. R8182H,J installation dimensions in in. (mm). Thermostat Anticipator Setting: 0.2A for R8182, 0.4A for each R845A Switching Relay used. Maximum Ambient Temperature (at Element): 250°F (121°C). R8182D,E,F FITS BOILER TAPPED HOLE CONTROL MOUNT 1/2 OR 3/4 NPT Maximum Pressure Rating: 200 psi (1379 kPa) on immersion well. 100 psi (689.5 kPa) direct immersion. Internal Views: Refer to Fig. 4 through 8. INSULATION LENGTH 1-1/2 OR 3 IN. (38 OR 76 MM) Well Insertion Length: 3-3/8 in. (86 mm). Immersion Well Dimensions (Order Well Separately): Refer to Fig. 3. INSERTION LENGTH 3-3/8 IN. (86 MM) R8182H,J SETSCREW Aquastat® Assembly Repair Parts: 125026AAE Aquastat® Assembly: Replaces R8182D,F Sensing Bulb. Replacement Well Assemblies: Refer to form 68-0040, Wells and Fittings for Temperature Controllers, for part numbers and descriptions. FITS BOILER TAPPED HOLE 1/2 OR 3/4 NPT INSULATION LENGTH 1-1/2 IN. (38 MM) INSERTION LENGTH 3-3/8 IN. (86 MM) M4530 Fig. 3. Approximate immersion well dimensions. Device R8182D R8182E Description 1-1/2 in. (38 mm) insulation, horizontal or vertical; 3 in. (76 mm) insulation horizontal. Part Number 125026AAD 3 in. (76 mm) insulation, vertical. 1250266AAE 1-1/2 in. (38 mm) insulation, horizontal or vertical; 3 in. (76 mm) insulation horizontal. 123726AV 3 in. (76 mm) insulation, vertical. 123726AW 3 68-0105—2 R8182D,E,F,H,J COMBINATION PROTECTORELAY™ AND HYDRONIC HEATING CONTROLS Device R8182F R8182H Description Part Number 1-1/2 in. (38 mm) insulation, horizontal or vertical; 3 in. (76 mm) insulation horizontal. 125017AAB 3 in. (76 mm) insulation, vertical. 125017AAC 1-1/2 in. (38 mm) insulation. 125026AAJ R8182J 123726AT Dial Stop: For restricting range, part no. 4074BRR for R8182D,F,H. GROUNDING SCREW Optional Specifications: R8182D,E,F: Case with long dimension horizontal. R8182H,J: End mounted hinge. GROUNDING SCREW SAFETY SWITCH RESET BUTTON TRANSFORMER FOR THERMOSTAT CIRCUIT AQUASTAT SWITCH SAFETY SWITCH RESET BUTTON TRANSFORMER FOR THERMOSTAT CIRCUIT CIRCULATOR RELAY (1K) DIFFERENTIAL SETTING BURNER MOTOR AND IGNITION RELAY (2K) CIRCULATOR RELAY (1K) BURNER MOTOR AND IGNITION RELAY (2K) VOLTAGE BARRIER LOW LIMIT SETTING HIGH LIMIT SETTING VOLTAGE BARRIER TRANSFORMER FOR CAD CELL CIRCUIT M4532 Fig. 5. Internal view of R8182E. HIGH LIMIT SETTING TRANSFORMER FOR CAD CELL CIRCUIT GROUNDING SCREW M4525 SAFETY SWITCH RESET BUTTON Fig. 4. Internal view of R8182D. HIGH LIMIT SETTING BURNER MOTOR AND IGNITION RELAY (2K) LOW LIMIT SETTING TRANSFORMER FOR CAD CELL CIRCUIT VOLTAGE BARRIER M4515 Fig. 6. Internal view of R8182F. 68-0105—2 4 R8182D,E,F,H,J COMBINATION PROTECTORELAY™ AND HYDRONIC HEATING CONTROLS INSTALLATION SAFETY SWITCH RESET BUTTON WARNING TRANSFORMER FOR THERMOSTAT CIRCUIT Explosion Hazard. Can cause severe injury, death or property damage. This product is intended for use only in systems with a pressure relief valve. DIFFERENTIAL SETTING CIRCULATOR RELAY (1K) When Installing this Product… 1. BURNER MOTOR AND IGNITION RELAY (2K) 2. LOW LIMIT SETTING 3. VOLTAGE BARRIER 4. HIGH LIMIT SETTING TRANSFORMER FOR CAD CELL CIRCUIT CAD CELL M4524 LEADS (YELLOW) Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. Check the ratings given in these instructions and on the product to be sure the product is suitable for your application. The installer must be a trained, experienced service technician. After completing installation, use these instructions to check product operation. WARNING Explosion or Electrical Shock Hazard. Can cause severe injury, death or property damage. 1. Disconnect the power supply before beginning installation to prevent electrical shock or equipment damage. 2. Be sure that combustion chamber is clear of oil or oil vapor before starting burner. 3. Be sure that the ambient temperature at the element will not exceed 250°F (121°C). Fig. 7. Internal view of R8182H. SAFETY SWITCH RESET BUTTON TRANSFORMER FOR THERMOSTAT CIRCUIT AQUASTAT SWITCH IMPORTANT Be sure that the sensing bulb fits snugly inside the immersion well and that the sensing bulb rests against the bottom of the immersion well. Refer to Fig. 9. 2K RELAY 1K RELAY VOLTAGE BARRIER Mounting the R8182 TRANSFORMER FOR CAD CELL CIRCUIT 1. 2. 3. HIGH LIMIT SETTING CAD CELL LEADS (YELLOW) 4. M4531 5. Fig. 8. Internal view of R8182J. 5 Disconnect the power supply. Drain all water from the boiler. Generally, boilers are equipped with a tapping that allows horizontal mounting of the immersion well where average temperature boiler water circulates freely. If no tapping is provided, prepare one. Install the immersion well or compression fitting (ordered separately) by threading the immersion well into the tapped hole. For R8182D,E,F models: a. Loosen the immersion well clamp screw on the side of the R8182 case. b. Insert the bulb into the immersion well until it bottoms. c. If necessary, bend the capillary tube to hold the bulb against the bottom of the immersion well. 68-0105—2 R8182D,E,F,H,J COMBINATION PROTECTORELAY™ AND HYDRONIC HEATING CONTROLS NOTE: Do not make sharp bends in the tubing. A sharp bend can break the tubing and cause a loss of fill. In models with an adjustable tubing length, pull the extra tubing out of the controller case. 6. d. Fit the controller case onto the immersion well so that the immersion well clamp slides over the flange of the immersion well. e. Securely tighten the immersion well clamp screw. For R8182H,J models: a. Loosen the screw holding the hinged backplate to the controller case and swing the backplate away from the controller case. b. Screw the backplate to a 4 by 4 inch junction box. c. Insert the bulb into the immersion well until it bottoms. d. If necessary, bend the capillary tube to hold the bulb against the bottom of the immersion well. NOTE: Do not make sharp bends in the tubing. A sharp bend can break the tubing and cause a loss of fill. In models with an adjustable tubing length, pull the extra tubing out of the controller case. 7. e. Tighten the immersion well screw over the brass collar. f. After wiring, swing control against the backplate and refasten with the screw. Refill the boiler and check for water leakage. Mounting the R8182D TRADELINE® If the existing immersion well does not fit the R8182D immersion well clamp, use a 1249094 immersion well adapter (order separately; see form 68-0040, Wells and Fittings for Temperature Controllers). 1. 2. 3. 4. 5. 6. Disconnect the power supply. Drain all water from the boiler. Fasten the R8182D immersion well clamp to the flange on the immersion well adapter. Refer to Fig. 9. Place the adapter on the capillary tube. Put the adapter end into the hole in the controller case and tighten the clamp screw. Insert the sensing bulb into the immersion well and bend the capillary tubing, if necessary, to hold the sensing bulb against the bottom of the immersion well. 68-0105—2 6 NOTE: Do not make sharp turns while bending the capillary tubing. In models with an adjustable tubing length, pull the extra tubing out of the controller case. 7. Apply the heat-conductive compound into the immersion well (if necessary). a. Fold the plastic bag of heat-conductive compound lengthwise and twist it gently. b. Cut off the end of the plastic bag and work the open end of the bag all the way into the immersion well. c. Slowly pull the bag out of the immersion well while squeezing it firmly to evenly distribute the heat-conductive compound. 8. Wipe off any excess grease and tighten the set screw against the adapter. If the existing immersion well is not usable, remove the existing immersion well and order a new one using form 68-0040, Wells and Fittings for Temperature Controllers. 1. 2. 3. 4. 5. Disconnect the power supply. Drain all water from the boiler. Install the new immersion well by threading it into the threaded hole. Loosen the immersion well clamp screw. See Fig. 9. Insert the sensing bulb into the immersion well and bend the capillary tubing, if necessary, to hold the sensing bulb against the bottom of the immersion well. NOTE: Do not make sharp turns while bending the capillary tubing. In models with an adjustable tubing length, pull the extra tubing out of the controller case. 6. 7. 8. 9. Apply heat-conductive compound into the immersion well (if necessary). a. Fold the plastic bag of heat-conductive compound lengthwise and twist it gently. b. Cut off the end of the plastic bag and work the open end of the bag all the way into the immersion well. c. Slowly pull the bag out of the immersion well while squeezing it firmly to evenly distribute the heat-conductive compound. Be sure the immersion well fits the hole in the controller case. Position the immersion well clamp snugly over the immersion well flange. Securely tighten the clamp screw. Refill the boiler and check for water leakage. R8182D,E,F,H,J COMBINATION PROTECTORELAY™ AND HYDRONIC HEATING CONTROLS CONTROLLER CASE IMMERSION WELL CLAMP BACK OF CONTROLLER CASE BOILER IMMERSION WELL CLAMP 1 IMMERSION WELL SPUD ADAPTER ADAPTER OLD IMMERSION WELL ASSEMBLY IMMERSION WELL CLAMP SCREW SENSING BULB (A) (D) (C) (B) 2 HEAT-CONDUCTIVE COMPOUND 1 CAPILLARY TUBE 2 ASSURE THAT CAPILLARY TUBE FITS FREELY IN THE ADAPTER SO THE TENSION OF THE CAPILLARY TUBE AT POINT (C) HOLDS THE SENSING BULB IN GOOD THERMAL CONTACT WITH THE IMMERSION WELL AT POINT (D). SETSCREW IMMERSION WELL CLAMP SCREW BEND THE CAPILLARY TUBE TO HOLD THE SENSING BULB IN GOOD THERMAL CONTACT WITH THE IMMERSION WELL AT POINTS (A) AND (B). SHORT TUBE FITS IN CENTRAL RECESS OF ADAPTER M8830 Fig. 9. Positioning the sensing bulb in the immersion well. WIRING Method 1 IMPORTANT Use Underwriters Laboratories Inc. listed connectors when making external circuit connections to the orange and white line voltage burner and ignition leadwires of the R8182H,J. WARNING 1. 2. 3. 4. Strip 7/16 in. of insulation from the wire end. Wrap the wire 3/4 of the distance around the screw as shown in method 1. Using a standard, flat-headed screwdriver, tighten the screw until the wipe is snugly in contact with the screw and contact plate. Tighten the screw pin an additional one-half turn. Method 2 Electrical Shock Hazard. Can cause severe injury, death or property damage. Disconnect power supply before wiring to prevent electrical shock or equipment damage. 1. 2. 3. 4. All wiring must comply with local codes, regulations, and ordinances. Strip 5/16 in. of insulation from the wire end. Insert wire beneath the screw as shown in method 2. Using a standard, flat-heat screwdriver, tighten the screw until the wire is snugly in contact with the screw and contact plate. Tighten the screw an additional one-half turn. NOTE: Do not use a push-type ratchet screwdriver. IMPORTANT Terminals on the R8182 are approved for copper wire only. The TRADELINE® R8182D,H can be converted to replace an R8182B,C,E,F or a White Rodgers 6C92-2 or 6C92-3. When replacing a White Rodgers model, the immersion well must also be replaced. Refer to Fig. 10 for Aquastat® limit connections necessary for each R8182D conversion. Follow the wiring instructions furnished by the appliance manufacturer, if available, or refer to Fig. 11 through 17. For wiring multiple zoning systems, refer to Fig. 16 and 17. To release the wires from the R8182, insert a screwdriver into the rectangular hole adjacent to the wire, push inward to release the locking-grip on the wire, and pull the wire out of the terminal hole. The R8182 is equipped with special wiring terminals. Wires can be wrapped around the terminal screw or inserted from the side. To reinsert the wire into a new terminal hole, simply push the wire into the new slot. 7 68-0105—2 R8182D,E,F,H,J COMBINATION PROTECTORELAY™ AND HYDRONIC HEATING CONTROLS USING THE TRADELINE® R8182D TO REPLACE R8182F: USING THE TRADELINE® R8182D TO REPLACE R8182B,E OR WHITE RODGERS 6C92: 1. REMOVE BLUE WIRE FROM THIS TERMINAL AND INSULATE END TO PREVENT CONTACT. 1. REMOVE WHITE ABD BLACK LEADS FROM THEIR TERMINAL AND CONNECT WITH A SODDERLESS CONNECTOR. 2. REMOVE OTHER BLUE WIRE FROM THIS TERMINAL AND CONNECT AS SHOWN BELOW. TO USE TRADELINE® R8182H TO REPLACE R8182J: 3. CONNECT CIRCULATOR TO ZC AND C2. BLUE 1. REMOVE RED AND WHITE LEADS FROM THEIR TERMINALS AND CONNECT WITH A SOLDERLESS CONNECTOR. WHITE BLUE COMPLETED WIRING TO REPLACE R8182C,F H I BLUE COMPLETED WIRING TO REPLACE R8182B,E AND WHITE RODGERS 6C92 L O H I YELLOW L O BLACK BLACK OR RED YELLOW Fig. 10. Converting TRADELINE® R8182D,H to replace other controls. 68-0105—2 8 M4526 R8182D,E,F,H,J COMBINATION PROTECTORELAY™ AND HYDRONIC HEATING CONTROLS 1 L1 (HOT) 1 L1 (HOT) L2 L2 R8182D R8182E 2 4 1 G 1 G 2 3 ZR 1K2 BLUE 2K1 3 BLACK B R B1 B LOW LIMIT R B2 C2 WHITE W HIGH LIMIT 2K2 ZR HIGH LIMIT BLUE 4 2 1K2 R TO OIL BURNER AND IGNITION TO WATER CIRCULATOR C1 ZC 1K1 1K1 CIRCULATOR B1 B2 C2 TO WATER CIRCULATOR C1 ZC TO OIL BURNER AND IGNITION B S.SW CONTACTS 2 2K1 SAFETY SWITCH HEATER S.SW CONTACTS 2K2 SAFETY SWITCH HEATER TRIAC 1K 2K C1 T C1 24 VOLT THERMOSTAT T R2 F T R2 F F R1 BILATERAL SWITCH T R1 BILATERAL SWITCH TRIAC 1K 2K 24 VOLT THERMOSTAT F C554A 1 120 VAC POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 WHEN THE BLACK AND WHITE WIRES ON THE TRADELINE® R8182D AQUASTAT® CONTROLLER ASSEMBLY ARE DISCONNECTED FROM THE CIRCULATOR SWITCH AND ARE INTERCONNECTED, LOW LIMIT AND CIRCULATOR CONTROL ARE BYPASSED. CIRCULATOR OPERATES WITHY THEROMSTAT ONLY. 3 TO REPLACE R8182C,F, REMOVE BLUE WIRE AND INSULATE END. DISCONNECT THE THE OTHER BLUE WIRE AT 4 AND WIRE TO B AT 3. WHEN CIRCULATOR IS CONNECTED BETWEEN ZC AND C2, LOW LIMIT FUNCTION IS REMOVED AND CIRCULATOR OPERATES WITH CIRCULATOR CONTROL (R TO W) ONLY. 4 CONTROL CASE MUST BE CONNECTED TO EARTH GROUND. USE GROUNDING SCREW PROVIDED. M4519 C554A 1 120 VAC POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 CONTROL CASE MUST BE CONNECTED TO EARTH GROUND. USE GROUNDING SCREW PROVIDED. M4527 Fig. 12. R8182E internal schematic and wiring diagram. Fig. 11. R8182D internal schematic and wiring diagram. 9 68-0105—2 R8182D,E,F,H,J COMBINATION PROTECTORELAY™ AND HYDRONIC HEATING CONTROLS 1 L1 (HOT) 1 L1 (HOT) L2 L2 R8182H R8182F 2 G 1 1 2 2 ZR HIGH LIMIT 1K2 R JUMPER HIGH LIMIT R W C1 CIRCULATOR C2 CONTROL B2 B B1 2K2 B TO WATER CIRCULATOR B TO BURNER AND IGNITION R 2K1 ORANGE R WHITE LOW LIMIT TO OIL BURNER AND IGNITION 1K1 W C1 ZC CIRCULATOR TO WATER CIRCULATOR C2 SAFETY SWITCH CONTACTS S.SW CONTACTS 2K1 T 2K 2K2 TRIAC T SAFETY SWITCH HEATER BILATERAL SWITCH R1 TRIAC 1K R2 F 2K C1 R1 BILATERAL SWITCH F T YELLOW T C554A 1 120 VAC POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 CONTROL CASE MUST BE CONNECTED TO EARTH GROUND. USE GROUNDING SCREW PROVIDED. 24 VOLT THERMOSTAT M4528 1 Fig. 13. R8182F internal schematic and wiring diagram. C1 R2 YELLOW 24 VOLT THERMOSTAT SAFETY SWITCH HEATER C554A 120 VAC POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M4520 Fig. 14. R8182H internal schematic and wiring diagram. 68-0105—2 10 R8182D,E,F,H,J COMBINATION PROTECTORELAY™ AND HYDRONIC HEATING CONTROLS 1 L1 (HOT) 24 VOLT THERMOSTAT L2 24 VOLT THERMOSTAT 24 VOLT THERMOSTAT R8182J 1 4 2 L1 (HOT) L2 1 HIGH LIMIT ZR B R YELLOW TO WATER CIRCULATOR 1K1 C2 5 L1 RED 3 T B1 T B2 C1 2K L2 TO OIL BURNER AND IGNITION RED RED SAFETY SWITCH HEATER 3 5 RED RED 2K1 5 RED 3 S.SW CONTACTS C2 2 TRIAC 1K R1 BILATERAL SWITCH C1 CIRCULATOR 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 R8182H AND J HAVE WHITE AND ORANGE LEADWIRES FOR OIL BURNER AND IGNITION CONNECTIONS. 3 RED LEADWIRES PROVIDED ONLY ON MODLES WITH END SWITCH. 4 CHOOSE AT72, AT87, OR AT88 TRANSFORMER TO MATCH MAXIMUM SYSTEM LOAD. 5 USE V8043 OR V8044 ZONE VALVES WITH AUXILIARY END SWITCH ONLY. R2 F F YELLOW YELLOW T 24 VOLT THERMOSTAT 1 YELLOW C1 ZC T YELLOW WHITE YELLOW 2K2 YELLOW 1K2 YELLOW TO OIL BURNER AND IGNITION ORANGE C554A 120 VAC POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M4522 Fig. 16. R8182D,E,F,H and J in a typical zoning application using zone valves. M4529 Fig. 15. R8182J internal schematic and wiring diagram. 11 68-0105—2 R8182D,E,F,H,J COMBINATION PROTECTORELAY™ AND HYDRONIC HEATING CONTROLS 6 ZONE 2 THERMOSTAT L1 (HOT) L2 1 2 1 R845A SWITCHING RELAY ZONE 2 R8182D G 1K 3 5 T BLUE ZR 3 HIGH LIMIT 1K2 4 2K1 B 1K1 T LOW LIMIT B2 C2 W 6 C1 ZC TO OIL BURNER AND IGNITION TO WATER CIRCULATOR 1K1 CIRCULATOR 2 B1 B 1K2 R 1 R 5 4 S.SW CONTACTS ZONE 2 CIRCULATOR 2K2 SAFETY SWITCH HEATER TO ADDITIONAL ZONES 3, 4, ETC. 1 120 VAC POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. TRIAC 1K 2 THERMOSTAT HEAT ANTICIPATOR SETTING, 0.2 AMP FOR R8182D. R1 BILATERAL SWITCH 3 THERMOSTAT HEAT ANTICIPATOR SETTING, 0.4 AMP FOR R845A. 4 CONTROL CASE MUST BE CONNECTED TO EARTH GROUND. USE GROUNDING SCREW PROVIDED. C1 T 5 R8182E,H,J CONNECTIONS FROM ZC AND ZR ARE IDENTICAL FOR MULTIPLE CIRULATOR ZONING APPLICAITON. 6 EACH ADDITIONAL ZONE REQUIRES A SEPARATE, FIELD-ADDED 24V THERMOSTAT AND R845 RELAY. 2K T R2 F F 2 24 VOLT THERMOSTAT C554A M4521 Fig. 17. R8182D and R845A in a typical multiple circulator zoning application. OPERATION R8182F R8182D A call for heat by the thermostat pulls in relay 1K, which energizes the safety switch circuit and relay 2K to turn on the burner. Safety switch starts to heat. If burner ignites within safety switch timing, the cadmium sulfide flame detector sees flame and the safety switch heater circuit is bypassed. The burner operates until the call for heat is satisfied. The circulator operates when relay 1K pulls in only if R to W is made in the Aquastat¨ limit. When R to B (low limit) is made by a drop in water temperature, it acts as a call for heat, pulling in relay 2K to turn on the burner. The circulator cannot operate. See Fig. 11, 16, 17 and 19. R8182E The burner and circulator operate whenever the thermostat calls for heat. Relay 2K pulls in. When the cadmium sulfide flame detector sees flame, the safety switch heater circuit is bypassed, and 2K is held in through 2K1. If temperature rises to a high limit setpoint, R to B breaks, shutting off the burner. The circulator continues operation under the thermostat direction. See Fig. 12, 16, 17 and 20. 68-0105—2 12 The thermostat call for heat pulls in relay 2K to turn on the burner. When the cadmium sulfide the flame detector sees flame, safety switch the heater circuit is bypassed. The circulator is independent of the thermostat circuit, being controlled only by the Aquastat¨ limit switch. See Fig. 13, 17 and 20. R8182H A call for heat by the thermostat pulls in relay 1K, which energizes the safety switch circuit and relay 2K to turn on the burner. The safety switch starts to heat. If the burner ignites within the safety switch timing, the cadmium sulfide flame detector sees the flame and the safety switch heater circuit is bypassed. The burner shuts Off when a call for heat is satisfied. The circulator operates when relay 1K pulls in only if R to W in the Aquastat¨ limit is made. When R to B (low limit) is made by a drop in water temperature, it acts as a call for heat, pulling in relay 2K to turn on the burner. The circulator cannot operate. See Fig. 14, 16, 17 and 18. R8182D,E,F,H,J COMBINATION PROTECTORELAY™ AND HYDRONIC HEATING CONTROLS R8182J The burner and circulator operate whenever the thermostat calls for heat. Relay 2K pulls in. When the cadmium sulfide flame detector sees flame, the safety switch heater circuit is bypassed, and 2K is held in through 2K1. If temperature rises to a high limit setpoint, R to B breaks, shutting off the burner. The circulator continues operation under direction of the thermostat. See Fig. 15, 16, 17 and 19. SWITCH BREAKS ON TEMPERATURE RISE. BURNER TURNS OFF. CIRCULATOR OPERATES ON A CALL FOR HEAT. HIGH LIMIT SETTING SWITCH MAKES ON TEMPERATURE FALL. BURNER OPERATES ON A CALL FOR HEAT. Multizone Control In all multizone applications, a call for heat in any zone energizes the safety switch circuit and relay 2K pulls in. If the burner ignites within the safety switch timing, the cadmium sulfide flame detector sees flame and the safety switch heater is bypassed. SWITCH MAKES R-W AND BREAKS R-B ON TEMPERATURE RISE. LOW LIMIT AND CIRCULATOR SETTING SWITCH MAKES R-W AND BREAKS R-B ON TEMPERATURE RISE. In all multizone applications with R8182D and H, the low limit control in the Aquastat® limit acts independently to turn on the main burner on a drop in water temperature. When R to B (low limit) is made, relay 2K pulls in to turn on the main burner, the same as for single-zone application. SWITCH MAKES R-B AND BREAKS R-W ON TEMPERATURE FALL. BURNER IS ON TO MAINTAIN MINIMUM WATER TEMPERATURE. CIRCULATOR IS OFF. 1 Zone Circulator Control with R8182D,H The relay for each zone is connected to the Aquastat® limit through terminals ZC and ZR. The R845 Relay and thermostat for each zone can energize the zone circulator through ZC only if R to W in the Aquastat® limit is made. If R to B (high limit) is made, the zone thermostat energizes the burner through ZR. Zone Circulator Control with R8182E,J The relay for each zone is connected to the Aquastat® limit through terminals ZC and ZR. The R845A Relay and thermostat in each zone can energize the zone circulator through ZC on a call for heat. If R to B (high limit) is made, the zone thermostat energizes the burner through ZR. WHEN WATER REACHES PROPER TEMPERATURE, THE BURNER SHUTS OFF OR THE CIRCULATOR PUMP STARTS (WHEN CALLING FOR HEAT). M1523 Fig. 18. R8182D,H Aquastat® limit switching. 240°F (116°C) R-B BREAKS ON TEMPERATURE RISE. BURNER TURNS OFF. CIRCULATOR OPERATES ON A CALL FOR HEAT. HIGH LIMIT SETTING 15°F (8°C) DIFFERENTIAL R-B MAKES ON TEMPERATURE FALL. BURNER AND CIRCULATOR OPERATE ON A CALL FOR HEAT. Zone Valve Control with R8182 The valve for each zone is connected to the Aquastat® limit by wiring end switches on the zone valve to T-T on the R8182. On a call for heat from any zone, the R8182 operates the same as for single zone applications. 1 M1510 180°F (82°C) Fig. 19. R8182E,J Aquastat® limit switching. 13 68-0105—2 R8182D,E,F,H,J COMBINATION PROTECTORELAY™ AND HYDRONIC HEATING CONTROLS Low Limit/Circulator Setting—D And H Models 240°F (116°C) HIGH LIMIT SETTING 10°F (6°C) DIFFERENTIAL CIRCULATOR SETTING 10°F (6°C) DIFFERENTIAL On a temperature rise, with the adjustable differential at the minimum setting of 10°F (6°C), the burner circuit (R-B) breaks and the circulator circuit (R-W) makes at the low limit setpoint. See Fig. 19. On a temperature drop of 10°F (6°C) below the setpoint, the R-B circuit makes and the R-W circuit breaks. R-B BREAKS ON TEMPERATURE RISE. BURNER TURNS OFF. R-B MAKES ON TEMPERATURE FALL. BURNER OPERATES ON CALL FOR HEAT. At any differential setting greater than 10°F (6°C), the R-B make temperature and R-W break temperature remains the same— setting minus 10°F (6°C). The R-B break and R-W make temperature are the setpoint temperature plus the difference between the differential setting and 10°F (6°C). R-W MAKES ON TEMPERATURE RISE. CIRCULATOR TURNS ON. EXAMPLE: Setpoint of 140°F (60°C); differential set at 25°F (14°C). On a temperature rise, R-B breaks and R-W makes at 155°F (68°C). On a temperature fall, R-B makes and R-W breaks at 130°F (54°C). R-B BREAKS ON TEMPERATURE FALL. CIRCULATOR TURNS OFF. 110°F (43°C) Set the low limit indicator at the minimum temperature recommended for domestic hot water supply. This setting must be at least 20°F (11°C) below the high limit setting to prevent one switch from locking out the other. M1509 Fig. 20. R8182F Aquastat® limit switching. Set the differential the desired number of degrees. STARTUP AND CHECKOUT Circulator Setting—F Models Set the circulator indicator at the minimum water temperature recommended for hydronic heating comfort. WARNING Explosion Hazard. Can cause severe injury, death or property damage. This product is intended for use only in systems with a pressure relief valve. Because heating systems differ, the correct temperature setting for one system may not be correct for another. Follow the boiler manufacturers recommendations for proper selection of settings. Part no. 126580 Setting Stops can be installed on the low and high limit adjusting knobs to prevent turning the knobs beyond a predetermined point. To install the setting stops, proceed as follows: IMPORTANT Once the setting stops are in place, they cannot be replaced. If they must be removed, cut off with cutters—do not twist off. 1. High Limit Setting—All Models The high limit opens and turns off the burner when the water temperature reaches the setpoint. The high limit automatically resets after the water temperature drops past the setpoint and through the 10°F (6°C) [15°F (8°C) with R8182E,J] differential. Set the indicator at the desired shutoff temperature. 68-0105—2 Setting Stops (R8182D,H TRADELINE®) 14 On low limit knob, turn the knob to the setting that is to be established as the limit. 2. Place the setting stop over the knob so that the arm of the setting stop (after the stop is pressed into place) strikes projection A and prevents turning the knob beyond the chosen limit setting. See Fig. 21. 3. Press the setting stop tightly onto the knob so its inner teeth securely engage the knob. 4. Turn knob back and forth several times to make sure stop functions properly. 5. Repeat steps 1 to 4 for the high limit knob. After settings are made, replace the cover. R8182D,E,F,H,J COMBINATION PROTECTORELAY™ AND HYDRONIC HEATING CONTROLS Make certain the system operates as described in the OPERATION section. Use the following procedure to verify that the Protectorelay™ burner sequencing relay is controlling properly. 1 STOP ARM SETTING Flame Failure Check Shut off the oil supply hand valve while the burner is on. After 45 seconds, the safety switch locks out, the motor stops, and the oil valve closes. Allow five minutes for the burner to cool, then manually reset the safety switch. 140 120 16 0 PROJECTION "A" SETTING STOP Ignition Failure Check Test by closing the oil supply while the burner is off. Run through the starting procedure but do not open the oil supply line hand valve. The safety switch locks out as in flame failure. Then turn the oil back on, and reset the safety switch. 200 180 KNOB SET AT 140°F (60°C) 1 SCALE MARKINGS IN FAHRENHEIT ONLY. Power Failure Check M4523 Fig. 21. Setting stop in position to restrict low limit setting to 180°F (82°C) or lower. Turn off the power supply while the burner is on. When the burner goes out, restore power and the burner will restart. NOTE: If operation is not as described, see cover insert for additional information and check wiring. Startup Aquastat® Controller Replacement The Aquastat® limit section of the Protectorelay™ control is field replaceable. When ordering a replacement assembly, specify the complete model number of the R8182. WARNING Explosion Hazard. Can cause severe injury, death or property damage. Be sure combustion chamber is free of oil or vapor. 1. 2. 3. 4. 5. Replace the Aquastat® Limit 1. 2. Push red reset button and release. Open hand valve on oil supply line. Set thermostat to call for heat. Close line switch; burner will start. Under normal conditions, burner operates until thermostat is satisfied or line switch is opened. 3. 4. Disconnect power supply. On all models—Note the position of the connecting wires. Remove fastening screws and wires. Remove Aquastat® limit and install the new assembly. MATERIAL SAFETY DATA SHEET (MSDS) SECTION 1. PRODUCT AND COMPANY IDENTIFICATION. Product Name: Heat conductive compound. Manufacturer: Honeywell Inc., 1985 Douglas Drive North, Minneapolis, MN 55422. Date Released: October 8, 1999. Emergency Telephone Information: 1-888-809-3787. MSDS ID: DS9021. NFPA Ratings: Synonyms: MS1699. Product Use: Heat conductive material used to enhance contact and heat transfer in temperature sensor applications. 15 Health 0; Flammability 1; Reactivity 0; Personal Protection B. 68-0105—2 R8182D,E,F,H,J COMBINATION PROTECTORELAY™ AND HYDRONIC HEATING CONTROLS Section 2. Composition, Information on Ingredients (Table 3). Table 2. Ingredients of Heat Conductive Compounda. Ingredients CAS Number Percent PEL TLV No. 2 Lithium Complex Grease (70%): Mineral Oil 64742-65-0 35-50 5 mg/m3 5 mg/m3 Mineral Oil 64742-62-7 20-25 5 mg/m3 5 mg/m3 Lithium Hydrostearate/Sebacate Complex 68815-49-6 4-9 — — Zinc Alkyldithiophosphate 68649-42-3 0-2 — — Aluminum, as Al 7429-90-5 20-25 15 mg/m3 10 mg/m3 Aliphatic Petroleum Distillates 8052-41-3 10-15 2900 mg/m3 525 mg/m3 — Aluminum Paste (30%): a Stearic Acid 57-11-4 1-2 Aromatic Petroleum Distillates 64742-95-6 1-2 — 3 5 mg/m 5 mg/m3 Additional Information: Part No. 120650 (0.5 oz. tube); Part No. 107408 (4 oz. can); Part number 197007 (5 gallon container). May also contain minute amounts of lithium and molybdenum lubricant compounds. Section 3. Hazard Identification Skin Contact: Remove excess with cloth or paper. Wash thoroughly with mild soap and water. Obtain medical attention if irritation develops and persists. Acute Health Effects: Skin—Excessive contact can cause skin irritation and dermatitis. Ingestion: Eye—Direct contact with eye will cause irritation. Contact physician or local poison control center immediately. Inhalation—No adverse effects are expected. Inhalation: Ingestion—Ingestion of product may cause nausea, vomiting and diarrhea. Remove patient to fresh air and obtain medical attention if symptoms develop. Chronic Health Effects: Section 5. Fire Fighting Measures Existing skin rash or dermatitis may be aggravated by repeated contact. Flash Point: >383°F (195°C). Will burn if exposed to flame. OSHA Hazard Classifications: Extinguishing Media: None. Carbon dioxide, dry chemical or foam. Carcinogenicity: Not considered to be a carcinogen by either OSHA, NTP, IARC, or ACGIH. Special Fire Fighting Procedures: Target Organs: Explosion Hazards: None. None known. Section 4. First Aid Measures None. Aluminum powder can react with water to release flammable hydrogen gas. In the form of this product, this reaction is not expected. Eye Contact: Section 6. Accidental Release Measures Scrape up and dispose as solid waste in accordance with state and federal regulations. Flush eyes with water for 15 minutes. Remove any contact lenses and continue to flush. Obtain medical attention if irritation develops and persists. Section 7. Handling and Storage Store in dry place. Keep container closed when not in use. 68-0105—2 16 R8182D,E,F,H,J COMBINATION PROTECTORELAY™ AND HYDRONIC HEATING CONTROLS Section 8. Exposure Controls and Personal Protection Incompatibilities: Strong oxidizing agents and halogens. Hazardous Decomposition Products: Ventilation: Carbon dioxide, carbon monoxide. No special ventilation is required when working with this product. Section 11. Toxicology Information Respiratory Protection: No data available. None required. Section 12. Ecological Information Eye Protection: Not normally required. However, use chemical safety goggles or faceshield if potential for eye contact exists, especially if material is heated. Hand/Clothing Protection: Not normally required. Protective gloves and clothing are recommended, as material is difficult to remove from skin and clothing. Other Protective Equipment: Chemical Fate Information: Hydrocarbon components will biodegrade in soil; relatively persistent in water. Section 13. Disposal Consideration Dispose of as solid waste in accordance with Local, State and Federal regulations. Section 14. Transportation Information None required. Section 9. Physical and Chemical Properties Appearance/Odor: DOT Classification: Not classified as hazardous. Section 15. Regulatory Information Aluminum color, semi-solid material, pleasant odor. SARA Title III Supplier Notification: Solubility in Water: 0.86. Include in Section 311/312 inventory reports if amounts exceed 10,000 pounds. Aluminum compounds are subject to the reporting requirements under Section 313 of Emergency Planning and Community Right-to-Know Act of 1986 (40 CFR 372). Ingredients listed in TSCA Inventory. Section 10. Stability and Reactivity Section 16. Other Information Negligible. Specific Gravity: This information is furnished without warranty, expressed or implied, except that it is accurate to the best of our knowledge. Stability: Stable. Prepared By: Reactivity: PROSAR, 1295 Bandana Boulevard, Suite 335, St. Paul, MN 55108 (651-917-6100). Hazardous polymerization will not occur. 17 68-0105—2 68-0105—2 18 19 68-0105—2 Automation and Control Solutions Honeywell Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 68-0105—2 G.R. Rev. 1-02 Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. www.honeywell.com/building/components
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Extract, Assemble, Print high-res Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 5.0 (Windows) Create Date : 1999:07:07 12:30:47Z Modify Date : 2007:05:07 14:16:03-05:00 Metadata Date : 2007:05:07 14:16:03-05:00 Creator Tool : FrameMaker 6.0 Format : application/pdf Creator : Honeywell Technical Communications Description : Product Data Title : 68-0105 - R8182D,E,F,H,J Combination Protectorelay and Hydronic Heating Controls Document ID : uuid:835ceb56-c2ec-4aa7-9946-1d39aa58ff91 Instance ID : uuid:c9919615-7428-4598-b258-5219cf9d9e0b Page Count : 20 Subject : Product Data Author : Honeywell Technical CommunicationsEXIF Metadata provided by EXIF.tools