MetroSelect®
Single-Line Scanner

Configuration Guide

Disclaimer
Honeywell International Inc. (“HII”) reserves the right to make changes in
specifications and other information contained in this document without prior
notice, and the reader should in all cases consult HII to determine whether any
such changes have been made. The information in this publication does not
represent a commitment on the part of HII.
HII shall not be liable for technical or editorial errors or omissions contained
herein: nor for incidental or consequential damages resulting from the
furnishing, performance, or use of this manual.
This document contains propriety information that is protected by copyright.
All rights reserved. No part of this document may be photocopied, reproduced,
or translated into another language without the prior written consent of HII.
© 2000 – 2011 Honeywell International Inc. All rights reserved.
Web Address: www.honeywellaidc.com

Trademarks
Omniplanar, MetroSet2, Metrologic, MetroSelect, RangeGate, CodeGate,
CodeSelect, Voyager, VoyagerCG, VoyagerBT and Focus are trademarks or
registered trademarks of Metrologic Instruments, Inc. or Honeywell
International Inc.
Microsoft and Windows are trademarks or registered trademarks of Microsoft
Corporation.
IBM is a trademark of International Business Machines Corporation.
The Bluetooth word mark is owned by the Bluetooth SIG, Inc. and any use of
such marks by Honeywell International Inc. is under license.
Other product names mentioned in this manual may be trademarks or
registered trademarks of their respective companies and are the property of
their respective owners.

Table of Contents
Introduction
Bar Code Configuration Methods .............................................................. 1–1
Single-Code Method .............................................................................. 1–1
Multi-Code Method ................................................................................ 1–1
Need to Start Over? .................................................................................. 1–2

Code Types and Decode Rules
UPC/EAN .................................................................................................. 2–1
Code 128 .................................................................................................. 2–2
Code 39 .................................................................................................... 2–2
2 of 5 Codes ............................................................................................. 2–4
Codabar .................................................................................................... 2–6
Code 93 .................................................................................................... 2–6
Code 11 .................................................................................................... 2–6
Telepen ..................................................................................................... 2–7
Plessey Codes .......................................................................................... 2–7
Additional Decode Features...................................................................... 2–8
Configurable Code Lengths ...................................................................... 2–9

Supplements .................................................................................... 3–1
GS1 Databar ..................................................................................... 4–1
GS1 Databar Limited ................................................................................ 4–2
GS1 Databar Expanded ............................................................................ 4–2

ISBT Code 128 Implementation
Configuration Mode .................................................................................. 5–1
Concatenation Configuration Mode .......................................................... 5–2
Pre-Defined Concatenation Configuration Mode ...................................... 5–2
User-Defined Concatenation Configuration Mode .................................... 5–3

Communications .............................................................................. 6–1

iii

Scanner Operation
Configuration Mode Options ...................................................................... 7–1
Scan Buffers .............................................................................................. 7–1
Redundant Scans ...................................................................................... 7–2
Miscellaneous Decode Features ............................................................... 7–2
Same Symbol Timeouts ............................................................................ 7–3
LED Options .............................................................................................. 7–3
Beeper Options ......................................................................................... 7–4
Data Transmission Delays......................................................................... 7–6
Communication Timeout Options .............................................................. 7–7
Host Scanner Commands ......................................................................... 7–8
Test Modes.............................................................................................. 7–10

Prefixes/Suffixes
User Configurable Prefixes, All Data ......................................................... 8–1
User Configurable ID Characters, Code Specific ...................................... 8–2
Standard Prefix Characters ....................................................................... 8–4
Standard Suffix Characters ....................................................................... 8–6
Longitudinal Redundancy Check ............................................................... 8–7
Block Check Character .............................................................................. 8–7
Character Replacements ........................................................................... 8–8
User Configurable Suffixes, All Data ......................................................... 8–9
Special Formats ...................................................................................... 8–10

Code Formatting
UPC/EAN Formatting ................................................................................ 9–1
Codabar Formatting .................................................................................. 9–3
Code 39 Formatting................................................................................... 9–4
Code 11 Formatting................................................................................... 9–4
Telepen ..................................................................................................... 9–4
Plessey ...................................................................................................... 9–5
2 of 5 Code Formatting .............................................................................. 9–5

iv

RS232
Parity Features ....................................................................................... 10–1
Baud Rate ............................................................................................... 10–1
Data/Stop Bits ......................................................................................... 10–2
Hardware Handshaking .......................................................................... 10–2
Software Handshaking ............................................................................ 10–4
Miscellaneous ......................................................................................... 10–5

Keyboard
Enable Keyboard Emulation ................................................................... 11–1
Country/Scan Code Table Selects .......................................................... 11–1
Keyboard/System Type........................................................................... 11–2
’Dumb’ Terminal Selections .................................................................... 11–3
Special Keyboard Features..................................................................... 11–4
InterScan Code Delays ........................................................................... 11–6
Control Sets ............................................................................................ 11–7

OCIA ................................................................................................ 12–1
Light Pen Parameters .................................................................... 13–1
Set Narrow Element Width...................................................................... 13–2

RS485 Configuration
IBM Port .................................................................................................. 14–1
IBM Reserve Codes ................................................................................ 14–1

USB.................................................................................................. 15–1
Code Bytes Usage
Code Bytes 0-9 ....................................................................................... 16–1
Reserved Codes ..................................................................................... 16–2
Code Type Table .................................................................................... 16–2
ASCII Reference Table ........................................................................... 16–3
Extended Key Code Reference Table..................................................... 16–7

v

®

®

MS9520 Voyager and MS9540 VoyagerCG Series
Activation Range ..................................................................................... 17–1
Stand Scan Modes .................................................................................. 17–1
CodeGate® Status .................................................................................. 17–1
Laser/Scan Modes .................................................................................. 17–2
Same Symbol Time Outs......................................................................... 17–3
MS9520/9540-00 Laser Emulation Mode ................................................ 17–4
®

MS9524 and MS9544 VoyagerPDF Series
PDF CodeGate Status ............................................................................. 18–1
MicroPDF and Composite Code Handling ............................................... 18–1

MS9535 VoyagerBT ....................................................................... 19–1
MS9535-5M VoyagerBT .................................................................. 20–1
Inventory Quantity Bar Codes ................................................................. 20–3

IS4125 and IS4225 Scan Engines ................................................. 21–1
IS4823 and IS4825 Scan Engines ................................................. 22–1
Operating Modes ..................................................................................... 22–1

Miscellaneous Features
Custom Defaults ...................................................................................... 23–1
Serial Program Mode .............................................................................. 23–2

Customer Support .......................................................................... 24–1
Technical Assistance............................................................................... 24–1
Product Service and Repair..................................................................... 24–2

vi

1
Introduction
Your new scanner has been factory configured with a set of default
parameters. Since many host systems have unique formats and protocol
requirements, Honeywell provides a wide range of configurable features
that may be selected using this bar code based configuration tool. Once the
configuration is completed, the scanner stores the settings in nonvolatile
memory (NOVRAM). NOVRAM saves the settings when the power is off.
Note: Bar code descriptions marked with an asterisk ( * ) define a feature that
is a factory default. Bar codes marked with a tilde ( ~ ) require the
Multi-Code configuration method.

Bar Code Configuration Methods
The MetroSelect class of scanners can be bar code configured in two ways:
the Single-Code Method and the Multi-Code Method.
Note: To properly configure an MS9540 scanner, all configuration
®
codes must be scanned using the CodeGate option.

Single-Code Method
Most features can be enabled or disabled using the Single-Code Method.
1.

Power-up the scanner.

2.

Scan the bar code for the desired feature.

3.

The scanner will emit a multi-toned beep to indicate the configuration
has been saved to NOVRAM.

Multi-Code Method
All features can be enabled or disabled using the Multi-Code Method.
A feature marked with a tilde ( ~ ) requires the Multi-Code Method.
1.

Power-up the scanner.

2.

Scan the enter/exit configuration mode bar code (3 beeps).

3.

Scan the bar code for the desired feature (1 beep). Multiple features
can be enabled/disabled before scanning the enter/exit configuration
mode bar code.

4.

Scan the enter/exit configuration mode bar code (3 beeps) and save
the new configuration. To abort a configuration change, power off the
scanner before scanning the enter/exit code.
Enter/Exit Configuration Mode
³

9

9

9

9

9

9

1–1

Need To Start Over?
Scan the Recall Defaults bar code to erase all previous settings and return
the scanner to its factory default communication protocol. Keyboard Wedge
interface scanners will load keyboard wedge defaults. All other scanners load
RS232 defaults.
Note: Honeywell manufactures several products for OEM applications.
These OEM products are configured with custom OEM defaults, which
may use a different set of defaults than the standard set of factory
defaults. See page 23–1 for additional information on custom defaults
and how they affect factory defaults.
Recall Defaults
³

1–2

9

9

9

9

9

8

2
Code Types and Decode Rules
Bar code descriptions marked with an asterisk ( * ) define a feature that is a
factory default. Bar codes marked with a tilde ( ~ ) require the Multi-Code
configuration method.

UPC/EAN
* Enable UPC/EAN
³

1

0

0

1

1

6

³

1

0

0

1

0

6

³

1

0

0

2

1

6

³

1

0

0

2

0

6

³

1

0

0

2

1

0

³

1

0

0

2

0

0

³

1

0

0

2

1

1

³

1

0

0

2

0

1

³

1

0

0

2

1

4

³

1

0

0

2

0

4

Disable UPC/EAN
* Enable UPC-A
Disable UPC-A
* Enable UPC-E
Disable UPC-E
* Enable EAN-13
Disable EAN-13
* Enable EAN-8
Disable EAN-8

2–1

Code 128
* Enable Code 128
³

1

0

0

1

1

3

³

1

0

0

1

0

3

³

1

0

0

3

1

4

³

1

0

0

3

0

4

³

1

0

0

7

1

1

³

1

0

0

7

0

1

Disable Code 128
Enable UCC/EAN-128 ‘]C1’ Code Formatting –
For Coupon Code 128, see page 3–3.
* Disable UCC/EAN-128 ‘]C1’ Code Formatting
Ignore  Code 128 Characters
* Use  to Determine Extended ASCII
Characters

Code 39
* Enable Code 39
³

1

0

0

1

1

1

³

1

0

0

1

0

1

³

1

0

0

2

1

3

³

1

0

0

2

0

3

³

1

0

0

2

1

7

³

1

0

0

2

0

7

Disable Code 39
Enable MOD 43 Check Digit on Code 39 – The
scanner only scans Code 39 bar codes that have
a valid Modulo 43 check digit.
* Disable MOD 43 Check Digit on Code 39
Enable Full ASCII Code 39
* Disable Full ASCII Code 39

2–2

³

1

0

0

2

1

5

³

1

0

0

2

0

5

³

1

0

0

3

0

7

³

1

0

0

3

1

7

³

1

0

0

3

1

2

³

1

0

0

3

0

2

³

1

0

0

7

0

2

³

1

0

0

7

1

2

³

1

0

0

4

1

6

³

1

0

0

4

0

6

³

1

0

0

9

1

4

³

1

0

0

9

0

4

³

1

0

7

7

1

5

³

1

0

7

7

0

5

Enable PARAF (Italian Pharmaceutical Codes)
Support – Code 39 bar codes are converted to
PARAF format.
* Disable PARAF Support
* Allow PARAF Codes Only
Allow Non-PARAF Codes
Enable TRI-OPTIC Code
* Disable TRI-OPTIC Code
* Use Standard Code 39 Framing
Try Code 39 Codes Without 5 Bar Multiples
Enable ITF/Code 39 Filters
* Disable ITF/Code 39 Filters
Enable Self-Service Library Code 39
* Disable Self-Service Library Code 39
Transmit MOD 43 Check Digit – with Self
Service Library Code 39
* Do Not Transmit MOD 43 Check Digit – with
Self Service Library Code 39

2–3

³

1

1

5

4

1

3

³

1

1

5

4

0

3

Enable Alternate Code 39 Reference
Comparison Check – assists with elements that
are below the 2 to 1 (wide to narrow) element
width requirement.
* Normal Code 39 Reference Comparison
Check

2 OF 5 CODES
* Enable Interleaved 2 of 5 (ITF)
³

1

0

0

1

1

5

³

1

0

0

1

0

5

³

1

0

0

3

1

0

³

1

0

0

3

0

0

³

1

0

7

8

1

7

³

1

0

7

8

0

7

³

9

0

1

6

0

0

³

9

0

1

7

0

0

³

9

0

3

4

0

0

Disable Interleaved 2 of 5 (ITF)

Enable MOD 10 Check on ITF – The scanner
will only scan Interleaved 2 of 5 (ITF) bar codes
that have a Modulo 10 check digit.
* Disable MOD 10 Check on ITF

Allow ITF Null Characters

* Do Not Allow ITF Null Characters

2–4

~ ITF Symbol Length Lock 1 – To specify a first
ITF symbol length lock, scan this bar code and
the appropriate code byte sequence located
on page 16–1.
~ ITF Symbol Length Lock 2 – To specify a second
ITF symbol length lock, scan this bar code and the
appropriate code byte sequence located
on page 16–1.
~ ITF Minimum Symbol Length – To specify a
minimum number of ITF characters to be decoded,
scan the appropriate code byte sequence located
on page 16–1.

Alternative ITF first Bar Reference
³

1

0

0

9

1

3

³

1

0

0

9

0

3

³

1

0

0

1

1

0

³

1

0

0

1

0

0

³

9

0

1

5

0

0

³

1

0

0

0

1

5

³

1

0

0

0

0

5

³

1

0

0

5

0

7

³

1

0

0

5

1

7

³

1

0

0

0

1

4

³

1

0

0

0

0

4

³

1

0

0

3

1

3

³

1

0

0

3

0

3

* Normal ITF first Bar Reference
Enable Standard 2 of 5
* Disable Standard 2 of 5
~ Standard 2 of 5 Symbol Length – To specify
the number of characters to be decoded, scan
this bar code and the appropriate code byte
sequence located on page 16–1.
Enable Matrix 2 of 5
* Disable Matrix 2 of 5
* Enable Matrix 2 of 5 Check Digit Requirement
Disable Matrix 2 of 5 Check Digit Requirement
Enable 15 Digit Airline 2 of 5
* Disable 15 Digit Airline 2 of 5
Enable 13 Digit Airline 2 of 5
* Disable 13 Digit Airline 2 of 5

2–5

Enable Hong Kong 2 of 5
³

1

0

0

3

1

6

³

1

0

0

3

0

6

³

1

1

5

4

1

1

³

1

1

5

4

0

1

* Disable Hong Kong 2 of 5
Enable Follett ITF
* Disable Follett ITF

Codabar
* Enable Codabar
³

1

0

0

1

1

4

³

1

0

0

1

0

4

³

1

0

0

0

1

2

³

1

0

0

0

0

2

Disable Codabar
Enable Dual Field Codabar
* Disable Dual Field Codabar

Code 93
* Enable Code 93
³

1

0

0

1

1

2

³

1

0

0

1

0

2

0

1

3

Disable Code 93

Code 11
Enable Code 11
³

2–6

1

0

0

* Disable Code 11
³

1

0

0

0

0

3

³

1

0

8

0

0

5

³

1

0

8

0

1

5

³

1

0

8

0

0

4

³

1

0

8

0

1

4

* Check for 1 Code 11 Check Digit
Check for 2 Code 11 Check Digits
* Do Not Check for 2 Code 11 Check Digits
Check for 2 Code 11 Check Digits if Code
Length is Greater Than 10 Characters

Telepen
Enable Telepen
³

1

0

0

0

1

7

³

1

0

0

0

0

7

³

1

0

0

0

1

6

³

1

0

0

0

0

6

* Disable Telepen
Enable ALPHA Telepen
* Disable ALPHA Telepen

Plessey Codes
Enable MSI Plessey
³

1

0

0

2

1

2

³

1

0

0

2

0

2

³

2

0

0

7

0

4

* Disable MSI Plessey
* No MSI Plessey Check Digit – Plessey bar
codes will not be tested for a check digit.

2–7

³

2

0

0

7

3

4

³

2

0

0

7

2

4

³

1

0

0

1

1

7

³

1

0

0

1

0

7

³

1

0

0

7

1

6

³

1

0

0

7

0

6

³

1

0

8

0

0

3

³

1

0

8

0

1

3

Enable MSI Plessey MOD 10/10 Check Digit –
Test MSI Plessey bar codes for a 2 digit
Modulo 10 check digit.
* Enable MSI Plessey MOD 10 Check Digit –
Test MSI Plessey bar codes for a 1 digit
Modulo 10 check digit.
Enable UK Plessey
* Disable UK Plessey
Enabled UK Plessey A to X Conversion
* Disabled UK Plessey A to X Conversion
* Standard Plessey Stop Characters
Accept Bad Plessey Stop Characters

Additional Decode Features
³

1

0

0

0

1

1

³

1

0

0

0

0

1

³

1

0

1

1

1

5

³

1

0

1

1

0

5

Enable Double Border Required / Large
Intercharacter Space
* Disable Double Border Required / Large
Intercharacter Space
Enable Small Border Required
* Disable Small Border

2–8

³

9

0

1

8

0

0

³

9

0

1

9

0

0

³

1

1

9

4

1

7

³

1

1

9

4

0

7

³

1

0

0

7

1

2

³

1

0

0

7

0

2

~ Minimum Symbol Length – Single-line default
is 3. Combine this code with the proper code bytes
(on page 16–1), to specify the minimum number
of characters in all non-UPC/EAN bar codes.
~ Symbol Length Lock – Combine this code with
the proper code bytes, to lock the bar code’s
length into place.
Enable Modulus 8 Filter on Bar & Space
Counts
* Disable Modulus 8 Filter on Bar & Space
Counts
Handle Code 39 Bad Border

* Disable Code 39 Bad Border

Configurable Code Lengths
There are seven bar code lock lengths available. Specific code types can be
assigned to a lock length.
While in configuration mode:
1. Scan the code length lock #1 bar code (below).
2. Scan the three code bytes that represent the code length
(on page 16–1).
3. Scan the matching code type lock #1 bar code (below).
4. Scan the three code bytes that represent the code type (on page 16–1).
This process can be repeated for lock lengths 2 through 7.
~ Code Length Lock #1
³

9

0

2

0

0

0

³

9

0

2

1

0

0

~ Code Type Lock #1

2–9

~ Code Length Lock #2
³

9

0

2

2

0

0

³

9

0

2

3

0

0

³

9

0

2

4

0

0

³

9

0

2

5

0

0

³

9

0

2

6

0

0

³

9

0

2

7

0

0

³

9

0

2

8

0

0

³

9

0

2

9

0

0

³

9

0

3

0

0

0

³

9

0

3

1

0

0

³

9

0

3

2

0

0

³

9

0

3

3

0

0

³

1

2

4

7

1

3

³

1

2

4

7

0

3

~ Code Type Lock #2
~ Code Length Lock #3
~ Code Type Lock #3
~ Code Length Lock #4
~ Code Type Lock #4
~ Code Length Lock #5
~ Code Type Lock #5
~ Code Length Lock #6
~ Code Type Lock #6
~ Code Length Lock #7.
~ Code Type Lock #7.

Enable Japanese Multi-Field
Disable Japanese Multi-Field

2–10

3
Supplements
Enable Two Digit Supplements
³

1

0

1

2

1

7

³

1

0

1

2

0

7

³

1

0

1

2

1

2

³

1

0

1

2

0

2

³

1

0

1

2

1

6

³

1

0

1

2

0

6

³

1

0

1

2

1

1

³

1

0

1

2

0

1

³

1

0

1

2

1

3

³

1

0

1

2

0

3

³

1

0

1

4

1

6

³

1

0

1

4

0

6

³

1

2

5

1

1

4

³

1

2

5

1

0

4

* Disable Two Digit Supplements
* Enable Two Digit Redundancies – The scanner
will scan the bar code plus the 2 digit add on
twice before accepting data.
Disable Two Digit Redundancies
Enable Five Digit Supplements
* Disable Five Digit Supplements
Enable Five Digit Redundancies – The scanner
will scan the bar code plus the 5 digit add on
twice before accepting data.
* Disable Five Digit Redundancies
Supplements are Required – All UPC/EAN
labels that are scanned must have a supplement.
* Supplements are Not Required
Enable Remote Supplement Required –
MS9500 & MS6200 not supported.
* Disable Remote Supplement Required –
MS9500 & MS6200 not supported.
Enable Bookland (979) Supplement Required
* Disable Bookland (979) Supplement Required

3–1

Enable Bookland (978) Supplement Required
³

1

0

1

4

1

7

³

1

0

1

4

0

7

³

1

0

1

3

1

4

³

1

0

1

3

0

4

³

1

0

1

3

1

3

³

1

0

1

3

0

3

³

1

0

1

4

1

3

³

1

0

1

4

0

3

³

1

0

1

4

1

5

³

1

0

1

4

0

5

³

1

0

1

4

1

2

³

1

0

1

4

0

2

³

1

0

1

2

1

5

³

1

0

1

2

0

5

* Disable Bookland (978) Supplement Required
Enable 977 (2 Digit) Supplement Required –
The scanner will require a 2 digit supplement to be
scanned when an EAN-13 code begins with 977.
* Disable 977 (2 Digit) Supplement Required
Enable 378/379 French Supplement Required
* Disable 378/379 French Supplement Required
Enable 414/419 German Bookland
Supplement Required
* Disable 414/419 German Bookland
Supplement Required
Enable 434/439 German Supplement Required
* Disable 434/439 German Supplement
Required
Enable # System 2 Requires Supplements
* Disable # System 2 Requires Supplements

3–2

Enable UPC # System 5 Requires
Supplements
* Disable UPC # System 5 Requires
Supplements

* Enable 2 Digit Supplements with 37x, 43x, or
UPC # System 5

³

1

0

1

0

0

0

³

1

0

1

0

1

0

³

1

0

1

0

0

1

³

1

0

1

0

1

1

³

1

0

0

3

1

5

³

1

0

0

3

0

5

³

1

0

1

4

1

1

³

1

0

1

4

0

1

³

1

0

1

4

1

4

³

1

0

1

4

0

4

³

3

0

1

3

4

0

400 msec to Find Supplemental – The scanner
will allot 400 milliseconds to find an add on after
a main UPC/EAN bar code has been scanned.

³

3

0

1

3

2

0

200 msec to Find Supplemental – The scanner
will allot 200 milliseconds to find an add on after
a main UPC/EAN bar code has been scanned.

³

3

0

1

3

1

0

* 100 msec to Find Supplemental – The scanner
will allot 100 milliseconds to find an add on after
a main UPC/EAN bar code has been scanned.

Disable 2 Digit Supplements with 37x, 43x, or
UPC # System 5
* Enable 5 Digit Supplements with 37x, 43x, or
UPC # System 5
Disable 5 Digit Supplements with 37x, 43x, or
UPC # System 5
Enable Coupon Code 128
* Disable Coupon Code 128
Enable Code 128 ‘]C1’ Extended Code Format
–The scanner transmits a ‘]C1’ at the beginning
of the Code 128 portion of the coupon code.
* Disable Code 128 ‘]C1’ Extended Code
Format.
* Enable Code 128 Group Separators – A “GS”
(1DH) character will be transmitted with coupon
Code 128 codes.
Disable Code 128 Group Separators

3–3

Enable Code ID’s with Supplements
³

1

0

1

2

1

4

³

1

0

1

2

0

4

³

1

1

8

4

0

6

³

1

1

8

4

1

6

³

1

0

1

3

1

5

³

1

0

1

3

0

5

³

1

0

1

3

1

7

³

1

0

1

3

0

7

³

1

0

1

3

1

6

³

1

0

1

3

0

6

³

1

2

5

1

1

5

³

1

2

5

1

0

5

³

1

2

5

1

0

6

³

1

2

5

1

1

6

* Disable Code ID’s with Supplements
* Beep Once on Supplements
Beep Twice on Supplements
Enable ISBN Check Digit Transmission – Not
available with all models.
Disable ISBN Check Digit Transmission
Enable Bookland to ISBN Conversion – Not
available with all models.
* Disable Bookland to ISBN Conversion
Enable ISBN Re-Formatting
* Disable ISBN Re-Formatting
Enable Bookland to ISBN 979 Conversion
* Disable Bookland to ISBN 979 Conversion
* Normal ISBN Re-Formatting
13 Digit ISBN Re-Formatting

3–4

Disable Supplemental when CodeGate Button
is Pressed – Available for MS9540 scanners
only. Requires standard Code Gate be inactive in
and out of stand.

³

1

0

1

2

1

0

³

1

0

1

2

0

0

* CodeGate Does Not Affect Supplemental
Scanning – Available for MS9540 scanners only.

³

1

2

5

0

1

7

No Supplement Checking if EAN-13 Code is
just scanned

³

1

2

5

0

0

7

* Normal Supplement Checking

3–5

3–6

4
GS1 DataBar
®

®

Honeywell’s MS9520 Voyager and MS9540 VoyagerCG scanners with
software #14810 and higher can be configured to scan GS1 DataBar type
bar codes.
³

1

0

0

0

1

1

³

1

0

0

4

1

3

³

1

0

0

4

0

3

³

1

1

4

9

0

0

³

1

1

4

9

1

0

³

1

1

4

9

0

1

³

1

1

4

9

1

1

³

1

1

4

9

0

2

³

1

1

4

9

1

2

Double Border Required – Due to the large
spaces commonly found in GS1 DataBar
symbologies, Honeywell recommends double
border requirements be enabled when scanning
GS1 DataBar code type symbologies.
Enable GS1 DataBar 14

* Disable GS1 DataBar 14

* Transmit GS1 DataBar 14 Check Digit

Do Not Transmit GS1 DataBar 14 Check Digit

* Transmit GS1 DataBar 14 Application ID –

Application Identifier “01” is transmitted
by default.
Do Not Transmit GS1 DataBar 14
Application ID

* Transmit GS1 DataBar 14 Symbology ID –
Symbology Identifier “]e0” is transmitted
by default.
Do Not Transmit GS1 DataBar 14 Symbology

4–1

GS1 DataBar Limited
Enable GS1 DataBar Limited
³

1

0

0

4

1

4

³

1

0

0

4

0

4

³

1

1

4

9

0

3

³

1

1

4

9

1

3

³

1

1

4

9

0

4

³

1

1

4

9

1

4

³

1

1

4

9

0

5

³

1

1

4

9

1

5

* Disable GS1 DataBar Limited
* Transmit GS1 DataBar Limited CD
Do Not Transmit GS1 DataBar Limited CD
* Transmit GS1 DataBar Limited Application ID –
Application identifier “01” is transmitted by default.
Do Not Transmit GS1 DataBar Limited
Application ID
* Transmit GS1 DataBar Limited Symbology ID –
Symbology identifier “]e0” is transmitted by default.
Do Not Transmit GS1 DataBar Limited
Symbology ID

GS1 DataBar Expanded
Enable GS1 DataBar Expanded
³

1

0

0

4

1

5

³

1

0

0

4

0

5

³

1

1

4

9

0

6

³

1

1

4

9

1

6

* Disable GS1 DataBar Expanded

4–2

* Transmit GS1 DataBar Expanded Symbol ID –
Symbology identifier “]e0” is transmitted by default.
Do Not Transmit GS1 DataBar Expanded
Symbol ID

5
ISBT Code 128 Implementation
Configuration Mode
³

1

3

8

4

1

7

³

1

3

8

4

0

7

Enable ISBT Code 128
Disable ISBT Code 128

The bar codes below enable or disable a special transmit mode as outlined in
section 3.5.2 of the ISBT-128 Specification. This output method allows the user
to confirm independently the accuracy of the Code-128 check digit.
³

1

3

8

4

1

6

³

1

3

8

4

0

6

Enable ISBT Special Transmit
Disable ISBT Special Transmit

The bar codes below enable or disable the transmission of the ISBT Code 128
data identifiers. When this option is enabled, the first two data characters
are removed from the data stream (ID characters) unless the ISBT bar code
scanned contains Donation Identification Number identifiers. If Donation
Identification Number identifiers are present, only the first ID character is
removed from the Donation ID Number. The second is regarded as
normal data.
³

1

3

8

4

1

5

³

1

3

8

4

0

5

Don’t Transmit ISBT ID’s
* Transmit ISBT Identifiers

The bar codes below convert and transmit the Mode 37, 2 check digit from the
flag digits of the Donation Identification Number provided the check digit is
contained in the flag digits. Transmission of the Donation Identification number
will be the same except for the last two digits, which are converted into a single
check sum character.
³

1

3

8

5

1

0

³

1

3

8

5

0

0

Convert Flag Digits to Mod 37, 2 CD
* Normal Flag Digit Transmission

5–1

Concatenation Configuration Mode

†

The following bar codes are used to configure variable time requirements used
to find the second bar code of the ISBT concatenation sequence.
³

3

0

1

3

1

0

³

3

0

1

3

2

0

³

3

0

1

3

3

0

³

3

0

1

3

4

0

³

3

0

1

3

5

0

³

3

0

1

3

6

0

³

3

0

1

3

7

0

100 msec to Find Concatenation Sequence
200 msec to Find Concatenation Sequence
300 msec to Find Concatenation Sequence
400 msec to Find Concatenation Sequence
500 msec to Find Concatenation Sequence
600 msec to Find Concatenation, Sequence
700 msec to Find Concatenation Sequence

Pre-Defined Concatenation Configuration Mode †
The first two bar codes below enable or disable pre-defined concatenation
sequences. The remaining bar codes enable the specific pre-defined
concatenation sequence shown, but are not needed to enable concatenation.
They can be used to disable or re-enable any selected pre-defined
concatenation sequence.
³

1

3

8

4

1

3

³

1

3

8

4

0

3

³

4

3

8

4

8

0

Enable Pre-Defined Concatenation Sequence
Disable Pre-Defined Concatenation Sequence
Donation Identification Number + AB0/Rh (D)
Blood Groups =á + =% Concatenation

† This feature is only supported in the MS9500 Voyager product series.

5–2

Donation Identification Number + Donor
Identification Number =á + &; Concatenation

³

4

3

8

4

9

0

³

4

3

8

4

1

0

0

Donation Identification Number + Confidential
Unit Exclusion Status =á + &! Concatenation

³

4

3

8

4

1

1

0

Product Code + Expiration Date (Form 1)
=< + =>Concatenation

³

4

3

8

4

1

2

0

Product Code + Expiration Date (Form 2)
=< + &> Concatenation

³

4

3

8

4

1

3

0

Product Code + Expiration Date (Form 3)
&< + => Concatenation

³

4

3

8

4

1

4

0

Product Code + Expiration Date (Form 4)
&< + &> Concatenation

User-Defined Concatenation Configuration Mode
The first two bar codes shown below can be used to enable or disable userdefined concatenation sequences. The remaining bar codes are used to enter
the user-defined identifiers used in the concatenation sequence. First enter
configuration mode then scan the one of the identifier codes, followed by the
code byte sequence or the desired identifiers.
³

1

3

8

4

1

4

³

1

3

8

4

0

4

³

9

3

8

0

0

0

³

9

3

8

1

0

0

³

9

3

8

2

0

0

³

9

3

8

3

0

0

Enable User-Defined Sequences
Disable User-Defined Sequences
st

1 Left Identifier
2

nd

Left Identifier

st

1 Right Identifier
2

nd

Right Identifier

† This feature is only supported in the MS9500 Voyager product series.

5–3

The following example demonstrates how to configure the User-Defined ISBT
identifiers:
Assume the left-hand identifiers are the ISBT defined donation
identification number: “=G”; and the right hand identifiers are country
specific identifiers “&a”.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.

Scan the ENTER/EXIT configuration mode bar code.
st
Scan the 1 Left Identifier configuration mode bar code.
Scan (Code Byte 0) + (Code Byte 6) + (Code Byte 1).
nd
Scan the 2 Left Identifier configuration mode bar code.
Scan (Code Byte 0) + (Code Byte 7) + (Code Byte 1).
st
Scan the 1 Right Identifier configuration mode bar code.
Scan (Code Byte 0) + (Code Byte 3) + (Code Byte 8).
nd
Scan the 2 Right Identifier configuration mode bar code.
Scan (Code Byte 0) + (Code Byte 9) + (Code Byte 7).
Scan the Enable User-Defined Sequence bar Code.
Scan the Enable ISBT bar code.
Scan the ENTER/EXIT configuration mode bar code.

The scanner is now configured with the appropriate identifiers. Since both
ISBT and User-defined Concatenation are enabled, ISBT 128 bar codes
scanned successively that contain these identifiers will be concatenated.
An alternate method of the type found in section 4.8.1 of the ISBT
specifications can be used for configuring user-defined concatenation
sequences. Using the previous example, the identifiers can be configured into
a single configuration mode bar code. The following bar codes can be used to
enable and disable the user-defined concatenation.
Enable (Left, =G) + (Right, &a)

=

&

³

=

G

&

a

5

0

5

d

1

Disable (Left, =G) + (Right, &a)

=

&

³

=

G

&

a

5

0

5

d

0

Note: These configuration bar codes require Single-Code configuration mode.
These bar codes are not recognized in Multi-Code configuration mode.
Two forms of concatenation can be enabled at any given time, one pre-defined
sequence and the user-defined sequence. Code selects and ISBT Code-128
concatenation cannot be used simultaneously. Both functions use the same
internal resources so they must remain mutually exclusive.

5–4

6
Communications
Enable Light Pen/Wand Communication –
Use this option if scanner should be used in
place of a light pen.

³

4

1

5

5

2

4

³

4

1

5

5

5

4

³

9

9

9

9

9

4

³

5

1

5

5

1

5

3

³

5

1

5

5

1

4

3

³

9

9

9

9

9

3

³

4

1

5

5

4

4

³

9

9

9

9

9

5

³

4

1

5

5

0

4

³

4

1

5

5

3

4

³

9

1

7

5

0

0

³

4

1

5

5

6
®

4

* Enable RS232 – The scanner will work with
RS232 +/- 12V serial output.
Load Keyboard Wedge Defaults – Scan this
code before selecting Normal or Stand Alone
Wedge Mode.
Enable Stand-Alone Keyboard Scanner –
Allows scanner to be used without an external
keyboard.
Enable Keyboard Wedge Emulation – Select if
the scanner provides keyboard emulation by
converting the scanned bar code data to the PC
keyboard scan code equivalent.
Load OCIA Defaults – Scan this code before
selecting Enable OCIA output.
Enable OCIA Output – Select this option if the
communications requirement is on Optically
Coupled Interface Adapter (OCIA). This is a
docked (by the host) serial interface.
†

Load RS485 Defaults
Enable RS485 Communication – Select this
option for RS485 SIOC/RS485 communications.
Not all scanners support this interface. The
correct interface board is required.
Enable No Communication Mode – Select this
option if the scanner does not interface with the
host device.
Reserved
Reserved
† Applicable for IBM Host applications.

6–1

6–2

7
Scanner Operation
Configuration Mode Options
³

1

1

8

1

1

7

³

1

1

8

1

0

7

³

1

1

8

1

1

6

³

1

1

8

1

0

6

Allow Configuration Mode on Power Up – The
scanner can only enter MetroSet mode before
any bar codes are scanned.
* Allow Configuration Mode Anytime – Allow
MetroSet configuration at any time.
Allow configuration Codes on Power Up –
Once a product bar code is scanned after powerup, the scanner will not accept configuration bar
codes.
* Allow Configuration Codes Anytime – Allows
scanning of configuration bar codes at any time.

Scan Buffers
* 1 Scan Buffer – The scanner will scan one bar
code in the scan field and not scan again until
the bar code is removed from the scan field for
the duration of the same symbol time out.

³

3

1

8

0

0

0

³

3

1

8

0

1

0

³

3

1

8

0

2

0

3 Scan Buffers – Same function as 2 Scan
Buffers, but three bar codes are in the scan field.

³

3

1

8

0

3

0

4 Scan Buffers – Same function as 2 Scan
Buffers, but four bar codes are in the scan field.

2 Scan Buffers – The scanner will scan two bar
codes in the scan field one time each. These two
bar codes will not be scanned again and until
they are removed from the scan field for the
duration of the same symbol time out.

7–1

Redundant Scans
* 0 Redundant Scans – Requires 1 good decode
for a good scan.

³

3

0

1

1

0

0

³

3

0

1

1

1

0

1 Redundant Scan – Requires 2 consecutive
decodes of the same bar code data for a good
scan.

³

3

0

1

1

2

0

2 Redundant Scans – Requires 3 consecutive
decodes of the same bar code data for a good
scan.

³

3

0

1

1

3

0

3 Redundant Scans – Requires 4 consecutive
decodes of the same bar code data for a good
scan.

³

3

0

1

1

4

0

4 Redundant Scans – Requires 5 consecutive
decodes of the same bar code for a good scan.

³

3

0

1

1

5

0

5 Redundant Scans – Requires 6 consecutive
decodes of the same bar code for a good scan.

³

3

0

1

1

6

0

6 Redundant Scans – Requires 7 consecutive
decodes of the same bar code for a good scan.

³

3

0

1

1

7

0

7 Redundant Scans – Requires 8 consecutive
decodes of the same bar code for a good scan.

Miscellaneous Decode Features
³

1

1

8

1

1

3

³

1

1

8

1

0

3

7–2

* Optional Same Symbol Check – Requires 1
different character between successive bar
codes to consider the bar code new.
Normal Same Symbol Check – Requires 3
different characters between successive bar
codes to consider the bar code new.

Same Symbol Time Outs
The length of time before a bar code can be rescanned after it is removed from
the scan field is user-configurable in increments of 50 msecs to 6350 msecs
(6.35 sec).
If using an MS9500 or IS4125, go to page 17–3.
³

9

1

8

9

0

0

³

8

1

8

9

0

0

³

1

1

8

9

1

7

³

1

1

9

4

1

4

³

1

1

9

4

0

4

~ Variable Same Symbol Time Out – While in
configuration mode, scan this bar code followed
by the appropriate code byte sequence (on page
16–1) to set the same symbol time out duration.
This feature is not supported for the MS9500
series or the IS4125, refer to page 17–3 for
additional information.
No Same Symbol Time Out
Infinite Same Symbol Time Out – The scanner
will not repetitively scan the same bar code.
This option overrides the symbol rescan time-outs.
Enable 2 Second Time Out – after 2 seconds of
inactivity the laser will turn off and stay off until
the CodeGate button is pressed. This feature is
for the MS5145 only.
Disable 2 Second Time Out

LED Options
³

1

1

8

3

1

3

³

1

1

8

3

0

3

³

1

1

8

3

1

2

³

1

1

8

3

0

2

Flash Green LED if Rescan Allowed – This
indicates same symbol timeout has elapsed.
Do Not Flash Green LED if Rescan Allowed
Reverse LED Functions – Red = Laser On
Green = Good Read
* Normal LED Functions – Green = Laser On
Red = Good Read

7–3

Beeper Options
* Normal Tone
³

3

1

8

5

7

5

³

3

1

8

5

6

5

³

3

1

8

5

5

5

³

3

1

8

5

4

5

³

3

1

8

5

3

5

³

3

1

8

5

2

5

³

3

1

8

5

1

5

³

3

1

8

5

0

5

³

1

1

8

4

0

6

³

1

1

8

4

1

6

³

1

1

8

4

1

4

³

1

1

8

4

0

4

³

1

1

8

5

1

2

³

1

1

8

5

0

2

Optional Tone 1
Optional Tone 2
Optional Tone 3
Optional Tone 4
Optional Tone 5
Optional Tone 6
No Beep
* Beep Once on Supplements
Beep Twice on Supplements
Enable Fast Beep
* Disable Fast Beep
Enable Fun Tones – scan this bar code then
scan one of the Optional Tone bar codes above.
* Disable Fun Tones

7–4

³

1

1

8

4

1

7

³

1

1

8

4

0

7

³

1

1

6

9

1

3

³

1

1

6

9

0

3

³

1

2

4

7

1

1

³

1

2

4

7

0

1

³

1

2

5

0

1

1

³

1

2

5

0

0

1

³

1

2

5

0

1

0

³

1

2

5

0

0

0

³

9

9

8

0

5

2

Beep on BEL Command – The scanner beeps
when it receives a BEL character from the host. If
a number is sent within 200 msecs before the
BEL character, the scanner will beep that
number of times.
* Ignore BEL Command
Enable Light Pen Toggle During Beep –
The scanner beeps and toggles the light pen
data line on a successful decode. This drives a
good read indicator.
* Disable Light Pen Toggle During Beep
Enable Pass-Through
Disable Pass-Through
Beep with Pass-Through Data
* No Beep with Pass-Through Data
Enable Record Count Capture
* No Record Count Capture
Transmit Record Counts

7–5

Data Transmission Delays
Use these codes to select the amount of delay between sending data
characters from the scanner to the host. This helps prevent the scanner from
overflowing host-input buffers.
* 1 msec Intercharacter Delay
³

8

1

8

8

1

0

³

8

1

8

8

1

0

0

³

8

1

8

8

2

5

0

³

9

1

8

8

0

0

³

8

1

8

8

0

0

³

9

1

9

3

0

0

³

1

1

9

3

1

7

³

1

1

9

3

0

7

10 msec Intercharacter Delay
25 msec Intercharacter Delay
~ Variable msec Intercharacter Delay – Scan this
bar code and a sequence of code bytes on page
16–1 to set the delay between characters sent to
the host system (range from 1 to 255 msecs.).
No Intercharacter Delay
~ Variable Inter-Record Delay
Turn Off Laser During Inter-Record Delay
* Leave Laser On During Inter-Record Delay

7–6

Communication Time Out Options
Enable Communications Time Out
³

1

1

8

4

1

2

³

1

1

8

4

0

2

³

1

1

8

4

1

3

³

1

1

8

4

0

3

³

9

1

9

1

0

0

³

8

1

9

1

4

0

0

³

8

1

9

1

2

0

0

³

8

1

9

1

8

0

0

³

1

1

8

4

1

0

³

1

1

8

4

0

0

³

1

1

8

4

1

1

³

1

1

8

4

0

1

* Disable Communications Time Out
* Beep Before Transmit
Beep After Transmit
~ Variable Communications Time Out
* Default Communications Time Out (2 secs)
Short Communications Time Out (1 secs)
Long Communications Time Out (4 secs)
Three Beeps on Time Out
* No Beeps on Time Out
Razzberry Tone on Time Out
* No Razzberry Tone on Time Out

7–7

Host Scanner Commands
Enable D/E Disable Command – The scanner
will disable scanning after it receives an ASCII
“D” from the host device. It will enable scanning
when it receives an ASCII “E”.

³

1

1

8

0

1

5

³

1

1

8

0

0

5

³

1

1

8

2

1

1

³

1

1

8

2

0

1

³

1

1

8

0

1

4

³

1

1

8

0

0

4

³

1

1

8

1

1

5

³

1

1

8

1

0

5

³

1

1

8

1

1

0

³

1

1

8

1

0

0

³

1

1

5

9

1

7

Transmit “METROLOGIC” with receipt of an
“I” (49H) via RS232

³

1

1

5

9

0

7

* Don’t Transmit “METROLOGIC” with receipt
of an “I” (49H) via RS232

* Disable D/E Disable.
Enable Z/R Type D/E Simulation – The scanner
will disable scanning after it receives an ASCII
“Z” from the host device. It will enable scanning
when it receives an ASCII “R”.
* No Z/R Type D/E Simulation
Enable F/L Laser Command – The scanner will
turn off the laser after the scanner receives an
ASCII “F” character. The laser will turn on after it
receives an ASCII “L” character.
* Disable F/L Laser Command
Use DTR Scan Disable – The scanner will
monitor the DTR input to determine if scanning
should be allowed. A +12V active level enables
decoding. A -12V inactive level disables decoding.
* Do Not Use DTR Scan Disable – Do not monitor
the DTR input.
Activate DC2 Character – Scanning will be
initiated with the receipt of a DC2 character
(^R, 124).
* Do Not Activate on DC2 Character

7–8

³

1

1

5

9

1

6

³

1

1

5

9

0

6

³

1

1

8

1

1

1

³

1

1

8

1

0

1

³

1

1

8

3

1

1

³

1

1

8

3

0

1

³

9

9

9

9

6

9

³

1

1

8

2

1

3

³

1

1

8

2

0

3

³

1

2

5

0

1

6

³

1

2

5

0

0

6

³

1

2

5

0

1

3

³

1

2

5

0

0

3

Transmit Scanner ID byte with receipt of an
“i” (69H) via RS232 – The ID byte is transmitted
as 3 bytes (i.e. 0, 0, 1).
* Don’t Transmit Scanner ID byte with receipt
of an “i” (69H) via RS232
Transmit NO READ if DC2 Activated
* Do Not Transmit NO READ if DC2 Activated
No Green LED During NO READ Transmit
* Green LED During NO READ Transmit
Transmit Serial Number
Enable Motor On/Off Commands
* Disable Motor On/Off Commands
Disable RS232 Receive
Normal RS232 Receive
Enable Banco Control Mode
Disable Banco Control Mode

7–9

³

1

4

1

7

1

5

³

1

4

1

7

0

5

³

1

1

9

9

1

7

³

1

1

9

9

0

7

Use Protocol Prefix and Suffix for Bar Code
Transmission
* No Protocol Prefix and Suffix for Bar Code
Transmission
Enable RTS on No Read – After a NOREAD
occurs, the scanner will activate the RTS line for
20 milliseconds. The duration of the RTS
activation can be loaded in address 199 bits 6–0
in 10 millisecond steps.
* Disable RTS on No Read

Test Modes
³

1

1

8

0

1

6

³

1

1

8

0

0

6

³

1

1

5

5

1

2

³

1

1

5

5

0

2

Scan Count Mode ON – The scanner will enter
scan count test mode and the scanner’s firmware
number will transmit to the host. Do not enable
unless instructed by a Honeywell representative.
* Scan Count Mode OFF

7–10

Power-Up with Saved Interface – Do not
enable unless instructed by a Honeywell
representative.
* Power-Up with Board Interface – Do not enable
unless instructed by a Honeywell representative.

8
Prefixes/Suffixes
Scan the Enter Configuration Mode bar code before trying to set these features
(see the Multi-Code Method on page 1–1).

User Configurable Prefixes, All Data
~ Configurable Prefix Character #1 – A prefix ID
can be added and assigned for data transmission.
Use this code with a code byte sequence, on page
16–1, which represents the desired character.

³

9

0

3

5

0

0

³

9

0

3

6

0

0

~ Configurable Prefix Character #2 – Assigns a
second configurable prefix character.

³

9

0

3

7

0

0

~ Configurable Prefix Character #3 – Assigns a
third configurable prefix character.

³

9

0

3

8

0

0

~ Configurable Prefix Character #4 – Assigns a
fourth configurable prefix character.

³

9

0

3

9

0

0

~ Configurable Prefix Character #5 – Assigns a
fifth configurable prefix character.

³

9

0

4

0

0

0

~ Configurable Prefix Character #6 – Assigns a
sixth configurable prefix character.

³

9

0

4

1

0

0

~ Configurable Prefix Character #7 – Assigns a
seventh configurable prefix character.

³

9

0

4

2

0

0

~ Configurable Prefix #8 – Assigns an eighth
configurable prefix character.

³

9

0

4

3

0

0

~ Configurable Prefix Character #9 – Assigns a
ninth configurable prefix character.

³

9

0

4

4

0

0

~ Configurable Prefix Character #10 – Assigns a
tenth configurable prefix character.

³

9

9

9

9

8

5

* Clear All User Configurable Prefixes

8–1

User Configurable ID Characters, Code Specific
³

1

0

5

5

0

7

³

1

0

5

5

1

7

* Use Configurable Code ID Bytes as Prefixes –
User configured, code specific ID bytes are
transmitted before the data. If using prefixes,
user configured suffixes cannot be used.
Use Configurable Code ID Bytes as Suffixes –
User configured, code specific ID bytes are
transmitted after the data. If using suffixes, user
configured prefixes cannot be used.

‡ Enter configuration mode then scan this bar code followed by the three
code byte bar codes (on page 16–1) that represent a unique ID character to
be associated with this bar code type.
~ Configurable UPC-A ID ‡
³

9

0

5

6

0

0

³

9

0

5

7

0

0

³

9

0

5

8

0

0

³

9

0

5

9

0

0

³

9

0

6

0

0

0

³

9

0

6

1

0

0

³

9

0

6

3

0

0

³

9

0

6

4

0

0

³

9

0

6

2

0

0

~ Configurable UPC-E ID ‡
~ Configurable EAN-8 ID ‡
~ Configurable EAN-13 ID ‡
~ Configurable Code 39 ID ‡
~ Configurable Code 128 ID ‡
~ Configurable Code 93 ID ‡
~ Configurable Code 11 ID ‡
~ Configurable Telepen ID ‡

8–2

‡

Enter configuration mode then scan this bar code followed by the three
code byte bar codes (on page 16–1) that represent a unique ID character
to be associated with this bar code type.
~ Configurable TRI-OPTIC ID ‡
³

9

0

7

2

0

0

³

9

0

7

1

0

0

³

9

0

6

7

0

0

³

9

0

6

8

0

0

³

9

0

6

9

0

0

³

9

0

6

5

0

0

³

9

0

7

0

0

0

³

9

0

6

6

0

0

³

9

9

9

9

8

3

³

1

0

5

5

1

6

³

1

0

5

5

0

6

³

1

2

4

7

1

6

³

1

2

4

7

0

6

~ Configurable Standard 2 of 5 ID ‡
~ Configurable Interleaved 2 of 5 ID ‡
~ Configurable Matrix 2 of 5 ID ‡
~ Configurable Airline 2 of 5 ID ‡
~ Configurable MSI Plessey ID ‡
~ Configurable UK Plessey ID ‡
~ Configurable Codabar ID ‡
* Clear All Configurable Code Specific ID’s –
Clears all unique ID characters previously
identified.
Enable Teraoka ID
* Disable Teraoka ID
Enable Taiwan 7-11 ID
* Disable Taiwan 7-11 ID

8–3

Standard Prefix Characters
³

1

1

6

6

1

5

³

1

1

6

6

0

5

³

1

0

5

5

1

3

³

1

0

5

5

0

3

³

1

0

7

9

1

5

³

1

0

7

9

0

5

³

1

1

6

6

1

7

³

1

1

6

6

0

7

³

1

0

7

9

1

1

³

1

0

7

9

0

1

³

9

4

1

5

0

0

³

1

0

7

9

1

7

³

1

0

7

9

0

7

Enable STX Prefix – The scanner will transmit a
Start of TeXt (ASCII 02H) before each bar code.
* Disable STX Prefix
Enable Rochford-Thomson Mode
* Disable Rochford-Thomson Mode
Enable AIM ID Characters
* Disable AIM ID Characters
Enable UPC Prefix ID – A prefix will be
transmited before any UPC/EAN code. The
prefixes are A (UPC-A), E0 (UPC-E), F (EAN-13),
and FF (EAN-8).
* Disable UPC Prefix ID.
Enable NCR Prefix ID – A prefix will be
transmitted before the following code types. The
prefixes are as follows: A (UPC-A), E0 (UPC-E),
FF (EAN-8), F (EAN 13), B1 (Code 39) B2 (ITF),
B3 (Code 128 and other codes).
* Disable NCR Prefix ID
Enable NCR Prefix Character
Enable Nixdorf ID Characters – This option
transmits code identities before each bar code
for many Siemen/Nixdorf registers.
* Disable Nixdorf ID Characters

8–4

Enable SANYO ID Characters
³

1

0

7

9

1

6

³

1

0

7

9

0

6

³

1

0

5

5

1

2

³

1

0

5

5

0

2

³

1

0

5

5

1

1

³

1

0

5

5

0

1

³

1

0

5

5

1

0

³

1

0

5

5

0

0

³

1

1

6

6

1

1

³

1

1

6

6

0

1

³

1

1

6

1

1

1

³

1

1

6

1

0

1

³

1

1

6

1

1

3

³

1

1

6

1

0

3

* Disable SANYO ID Characters
Enable Manufacturer ID Prefix
* Disable Manufacturer ID Prefix
Enable “C” Prefix
* Disable “C” Prefix
Enable “$” Prefix ID for UPC/EAN
* Disable “$” Prefix ID for UPC/EAN
Enable Tab Prefix – The scanner will transmit a
TAB (ASCII 09H) before each bar code.
* Disable Tab Prefix
Enable SNI Beetle Mode
* Disable SNI Beetle Mode
Enable Cipher 1021 IDs
* Disable Cipher 1021 IDs

8–5

Enable Tec 7-11 IDs
³

1

2

4

6

1

0

³

1

2

4

6

0

0

* Disable Tec 7-11 IDs

Standard Suffix Characters
* Enable CR Suffix – The scanner transmits a
³

1

1

6

6

1

3

³

1

1

6

6

0

3

³

1

1

6

6

1

2

³

1

1

6

6

0

2

³

1

1

6

6

1

0

³

1

1

6

6

0

0

³

1

1

6

6

1

4

³

1

1

6

6

0

4

³

1

1

6

6

1

6

³

1

1

6

6

0

6

carriage return after each bar code.
Disable CR Suffix.

* Enable LF Suffix – The scanner transmits a line
feed after each bar code. Disabled when
keyboard wedge defaults are loaded.
Disable LF Suffix.
Enable Tab Suffix – The scanner will transmit a
TAB (ASCII 09H) after each bar code.
* Disable Tab Suffix
Enable ETX Suffix – The scanner will transmit
End of TeXt (ASCII 03H) after the bar code date.
* Disable ETX Suffix
Enable UPC Suffix ID – The scanner will
transmit a suffix after any UPC/EAN bar code.
The suffixes are A (UPC-A), E (UPC-E),
F (EAN-13) and F (EAN-8).
* Disable UPC Suffix ID

8–6

Enable NCR Suffix Character
³

9

4

1

6

0

0

Longitudinal Redundancy Check
A Longitudinal Redundancy Check (LRC) is an error checking character that is
calculated across a sequence of data characters. It is determined by eXclusive
ORing (XOR) the characters to be checked, starting with an initial value of
00H.
The result, an “LRC byte” is then transmitted following the data stream and
used by the receiving computer to determine if the information was received
correctly. In the scanner’s case, XOR is performed prior to adding parity bits.
When the LRC is enabled, the scanner defaults to starting the LRC on the
second byte of information transmitted. Optionally, the calculation can start on
the first byte transmitted.

³

1

0

7

8

1

1

³

1

0

7

8

0

1

³

1

0

7

8

0

0

³

1

0

7

8

1

0

Enable Transmit of LRC Calculation – The
scanner outputs on LRC check character after
the bar code.
* Disable Transmit of LRC Calculation.
* Start LRC on First Byte – The scanner will
calculate the LRC check digit starting with the
first character.
Start LRC on Second Byte – The scanner will
calculate the LRC check digit starting with the
second character.

Block Check Character
* Enable NCR BCC
³

1

4

1

4

0

0

³

1

4

1

4

1

0

Disable NCR BCC

8–7

Character Replacements
To replace a character:
1.

Scan the enter/exit configuration mode bar code (on page 1–1).

2.

Scan the character to replace code (shown below).

3.

Scan the ASCII code byte value of the character you wish to replace.
Refer to the ASCII Reference Table in the Code Byte Usage section of
this manual.

4.

Scan the replacement character bar code (shown below).

5.

Scan the ASCII code byte value of the replacement character.

6.

Scan the enter/exit configuration mode bar code (on page 1–1).
~ Character to Replace

³

9

3

8

6

0

0

³

9

3

8

7

0

0

³

8

3

8

6

0

0

~ Replacement Character

No Replacement

8–8

User Configurable Suffixes, All Data
Note: Scan the Enter/Exit Configuration mode code before trying to set this
feature. Refer to Multi-Code Method on page 1–1.
~ Configurable Suffix Character #1 – A suffix ID
can be added and assigned for data
transmission. Use this code with a 3 code byte
sequence, on page 16–1, which represents the
desired character.

³

9

0

4

5

0

0

³

9

0

4

6

0

0

~ Configurable Suffix Character #2 – Assigns a
second configurable suffix character.

³

9

0

4

7

0

0

~ Configurable Suffix Character #3 – Assigns a
third configurable suffix character.

³

9

0

4

8

0

0

~ Configurable Suffix Character #4 – Assigns a
fourth configurable suffix character.

³

9

0

4

9

0

0

~ Configurable Suffix Character #5 – Assigns a
fifth configurable suffix character.

³

9

0

5

0

0

0

~ Configurable Suffix Character #6 – Assigns a
sixth configurable suffix character.

³

9

0

5

1

0

0

~ Configurable Suffix Character #7 – Assigns a
seventh configurable suffix character.

³

9

0

5

2

0

0

~ Configured Suffix Character #8 – Assigns an
eighth configurable suffix character.

³

9

0

5

3

0

0

~ Configurable Suffix Character #9 – Assigns a
ninth configurable suffix character.

³

9

0

5

4

0

0

~ Configurable Suffix Character #10 – Assigns a
tenth configurable suffix character.

³

9

9

9

9

8

4

* Clear All User Configurable Suffixes

8–9

Special Formats
Enable SINEKO Mode
³

1

0

7

9

1

4

³

1

0

7

9

0

4

³

1

1

6

7

1

1

³

1

1

6

7

0

1

³

1

1

6

7

1

0

³

1

1

6

7

0

0

³

1

0

8

0

1

7

³

1

0

8

0

0

7

³

1

1

6

7

1

3

³

1

1

6

7

0

3

³

1

2

4

7

1

5

³

1

2

4

7

0

5

* Disable SINEKO Mode
Enable Newcode Formatting Mode A
* Disable Newcode Formatting Mode A
Enable Newcode Formatting Mode B
* Disable Newcode Formatting Mode B
Remove All Leading Zero’s
* Do Not Remove Leading Zero’s
Enable MS951 CAPS Lock
* Disable MS951 CAPS Lock
Enable HCA Parsing
Disable HCA Parsing

8–10

9
Code Formatting
UPC/EAN Formatting
* Transmit UPC-A Check Digit
³

1

0

7

5

1

7

³

1

0

7

5

0

7

³

1

0

7

5

1

6

³

1

0

7

5

0

6

³

1

0

7

5

1

5

³

1

0

7

5

0

5

³

1

0

7

6

0

2

³

1

0

7

6

1

2

³

1

0

7

5

1

0

³

1

0

7

5

0

0

³

1

0

7

5

1

4

³

1

0

7

5

0

4

Do Not Transmit UPC-A Check Digit
Transmit UPC-E Check Digit
* Do Not Transmit UPC-E Check Digit
Expand UPC-E to 12 Digits – Expand UPC-E bar
codes to the 12 digit equivalent, UPC-A bar codes.
* Do Not Expand UPC-E to 12 Digits
* Send Number System on Expanded UPC E
Do Not Send Number System on Expanded
UPC E
Enable GTIN Formatting
* Disable GTIN Formatting
Convert UPC-A to EAN-13 – The scanner
converts UPC-A to EAN-13 by transmitting a
leading zero before the bar code.
* Do Not Convert UPC-A to EAN-13

9–1

³

1

0

7

5

1

3

³

1

0

7

5

0

3

³

1

0

7

5

1

2

³

1

0

7

5

0

2

³

1

0

7

5

1

1

³

1

0

7

5

0

1

³

1

0

7

6

1

1

³

1

0

7

6

0

1

³

1

0

7

6

1

0

³

1

0

7

6

0

0

³

1

0

7

9

1

0

³

1

0

7

9

0

0

³

1

0

7

9

1

2

³

1

0

7

9

0

2

Transmit Lead Zero on UPC-E – This option will
transmit a zero before each UPC-E bar code.
Do Not Transmit Lead Zero on UPC-E
Convert EAN-8 to EAN-13 – The scanner will
transmit five zeros before the bar code to convert
EAN-8 to EAN-13.
* Do Not Convert EAN-8 to EAN-13
* Transmit UPC-A Number System
Do Not Transmit UPC-A Number System
* Transmit UPC-A MFR #
Do Not Transmit UPC-A MFR #
* Transmit UPC-A ITEM #
Do Not Transmit UPC-A ITEM #
* Transmit EAN-8 Check Digit
Do Not Transmit EAN-8 Check Digit
* Transmit EAN-13 Check Digits – The scanner
will transmit EAN-13 Check Digit.
Do Not Transmit EAN-13 Check Digit.

9–2

Codabar Formatting
³

1

0

7

7

1

7

³

1

0

7

7

0

7

³

1

1

5

1

0

0

³

1

1

5

1

1

0

³

1

0

7

7

1

6

³

1

0

7

7

0

6

³

1

0

0

4

1

0

³

1

0

0

4

0

0

³

1

0

0

4

1

1

³

1

0

0

4

0

1

³

1

0

8

0

0

6

³

1

0

8

0

1

6

Transmit Codabar Start/Stop Characters –
Transmits Codabar’s Start/stop characters before
and after each bar code.
* Do Not Transmit Codabar Start/Stop
* Normal Codabar Start/Stop Characters
Enable Transmit Codabar Start/Stop
Characters as Lower Case Characters
Enable CLSI Editing – Works only with 14 digit
Codabar type lengths. This option will perform
CLSI type editing before the information is
transmitted to the host.
* Do Not Enable CLSI Editing
Enable Codabar Mod-16 Check Digit
* Disable Codabar Mod-16 Check Digit
Enable Codabar “7-Check” Check Digit
* Disable Codabar “7-Check” Check Digit
* Transmit Codabar Check Digit
Don’t Transmit Codabar Check Digit

9–3

Code 39 Formatting
³

1

0

7

7

1

5

³

1

0

7

7

0

5

³

1

0

7

7

1

0

³

1

0

7

7

0

0

³

1

0

7

7

1

2

³

1

0

7

7

0

2

Transmit Mod 43 Check Digit on Code 39 –
This feature works in conjunction with Mod 43
Check Digit on Code 39 option, on page 2–2.
Both must be enabled for this feature to work.
* Do Not Transmit Mod 43 Check Digit on
Code 39
Transmit Code 39 Stop/Start Characters –
The scanner transmits Code 39’s start and stop
characters before and after each bar code.
* Do Not Transmit Code 39 Stop/Start
Characters
Transmit an “A” (41H) Prefix if Italian
Pharmaceutical
* Do not Transmit an “A” (41H) Prefix if Italian
Pharmaceutical

Code 11 Formatting
³

1

0

7

7

1

3

³

1

0

7

7

0

3

Transmit Code 11 Check Digit – This bar code
will transmit Code 11 check characters when
used with Enabled Code 11 on page 2–6.
* Do Not Transmit Code 11 Check Digit

Telepen
Enable Convert Telepen ^L to E
³

1

0

7

8

1

4

³

1

0

7

8

0

4

* Disable Convert Telepen ^L to E

9–4

Plessey
³

1

0

7

8

1

6

³

1

0

7

8

0

6

³

1

0

7

8

1

5

³

1

0

7

8

0

5

³

1

0

7

7

1

1

³

1

0

7

7

0

1

Transmit UK Plessey Check Digit – The scanner
will transmit UK Plessey Check Digit characters
and must be used with the UK Plessey option.
* Do Not Transmit UK Plessey Check Digit
Enable UK Plessey Special Format
Disable UK Plessey Special Format
Transmit MSI Plessey Check Digit – This option
works in conjunction with one or both of the
Enabled MSI Plessey Mod options on page 2–7.
* Do Not Transmit MSI Plessey Check Digit

2 of 5 Code Formatting
³

1

0

7

7

1

4

³

1

0

7

7

0

4

³

1

0

7

8

1

2

³

1

0

7

8

0

2

Transmit Mod 10 Check Digit on ITF – The
scanner transmits interleaved 2 of 5 (ITF) Mod 10
check character.
* Do Not Transmit Mod 10 Check Digit on ITF –
Works in conjunction with Mod 10 check on ITF.
Both must be enabled for this feature to work.
Transmit Matrix 2 of 5 Check Digit
* Do Not Transmit Matrix 2 of 5 Check Digit

9–5

9–6

10
RS232
³

4

1

5

5

5

* Enable RS232 Mode – The scanner will work
with RS232 +/-12V serial output.

4

Parity Features
A parity bit is an extra data bit used to help catch data transmission errors.
The scanner’s parity must match the host’s parity.
No Parity
³

3

1

6

0

4

5

³

3

1

6

0

0

5

³

3

1

6

0

1

5

³

3

1

6

0

2

5

Even Parity – Select to set the parity bit to either
a 1 or 0 to ensure an even number of bits are 1s.

³

3

1

6

0

3

5

Mark Parity – Select Mark Parity to set the parity
bit always to 1.

Odd Parity – Select to set the parity bit to either a
1 or a 0 to ensure an odd number of bits are 1s.
* Space Parity – Select to set the parity bit
always to 0.

Baud Rate
³

4

1

5

8

1

0

0

³

4

1

5

8

9

0

³

4

1

5

8

8

0

³

4

1

5

8

7

0

³

4

1

5

8

6

0

115200 BAUD Rate
(Not available with Voyager)
57600 BAUD Rate
(Not available with Voyager)
38400 BAUD Rate
19200 BAUD Rate
14400 BAUD Rate

10–1

* 9600 BAUD Rate
³

4

1

5

8

5

0

³

4

1

5

8

4

0

³

4

1

5

8

3

0

³

4

1

5

8

2

0

³

4

1

5

8

1

0

³

4

1

5

8

0

0

4800 BAUD Rate
2400 BAUD Rate
1200 BAUD Rate
600 BAUD Rate
300 BAUD Rate

Data/Stop Bits
³

1

1

6

0

1

3

³

1

1

6

0

0

3

³

1

1

6

0

1

4

³

1

1

6

0

0

4

8 Data Bits – The number of data bits
transmitted for each character.
* 7 Data Bits
1 Stop Bit
* 2 Stop Bits

Hardware Handshaking
³

1

1

5

8

1

6

³

1

1

5

8

0

6

Enable RTS/CTS Handshaking – Output a
Request to Send (RTS) signal and wait for a Clear
to Send (CTS) signal before transmitting data.
* Disable RTS/CTS Handshaking.

10–2

* Character RTS/CTS – Activates/Deactivates
RTS signal for each character.

³

1

1

5

8

1

5

³

1

1

5

8

0

5

³

1

2

4

5

1

0

³

1

2

4

5

0

0

³

1

2

4

5

1

1

³

1

2

4

5

0

1

³

1

2

4

5

1

2

³

1

2

4

5

0

2

* Activate RTS, Wait for CTS – Wait for CTS after
activating RTS.

³

1

2

4

5

1

3

Test CTS Not Present Before RTS (RSV4) – Do
not activate RTS if CTS is already present.

³

1

2

4

5

0

3

³

1

1

5

8

1

7

³

1

1

5

8

0

7

Message RTS/CTS – Activates RTS before
sending the first character and leaves it active
until after the last character has been
transmitted.
Invert RTS Polarity (RSV1)
-12V = Active
+12V = Inactive
* Standard RTS Polarity – Use standard RTS
polarity
-12V = Inactive
+12V = Active
Invert CTS Polarity (RSV2)
-12V = Active,
+12V = Inactive,
OK to send
Do not send
* Standard CTS Polarity
-12V = Inactive,
Do not send

+12V = Active,
OK to send

Activate RTS, Do Not Wait for CTS (RSV3) –
Activate RTS for transmission but do not wait for
CTS to send.

* Do Not Test for CTS Present Before RTS

Enable DTR Support – The scanner will stop
scanning when the Data Terminal Ready (DTR)
signal goes inactive.
* Disable DTR Support

10–3

³

1

1

5

9

1

5

³

1

1

5

9

0

5

³

1

1

5

9

1

4

³

1

1

5

9

0

4

Enable RTS Counter Toggle – The scanner will
toggle the RTS line on a good decode.
* Disable RTS Counter Toggle

Enable XON/XOFF Handshaking – The scanner
will stop transmission whenever on XOFF
(ASCII 13H) is received. Transmission will
resume after an XON (ASCII 11H) is received.
* Disable XON/XOFF Handshaking.

Software Handshaking
³

1

1

5

9

1

3

³

1

1

5

9

0

3

³

1

1

5

9

1

1

³

1

1

5

9

0

1

³

1

1

8

0

1

3

³

1

1

8

0

0

3

Enable ACK/NAK – After transmitting data, wait
for an ACK (06H) or a NAK (15H) response from
the host. If ACK is received, complete the
communications cycle and look for more bar
codes. If NAK is received, retransmit the last set
of bar code data and wait for ACK/NAK again.
* Disable ACK/NAK
Support BEL/CAN in ACK/NAK – When BEL
(07H) is received, the scanner beeps 3 times and
exits the communications loop. If a CAN (18H) is
received, then the scanner will exit the
communications loop, silently.
* Ignore BEL/CAN in ACK/NAK – Ignore
BEL/CAN characters in communication loop.
Enable 5 Retries on ACK/NAK Time Out –
Allow up to 5 NAK retransmissions of the data
before dropping out of the communications loop.
* Disable 5 Retries on ACK/NAK Time Out

10–4

³

1

1

5

8

1

4

³

1

1

5

8

0

4

³

1

2

5

2

1

0

³

1

2

5

2

0

0

Enable 5 NAK Retries
Allow up to 5 retransmissions of the data if a
NAK is received.
* Disable 5 NAK Retries
Enable GLS Handshaking – Accept ]V for the
ACK acknowledgement. ACK will no longer be
accepted but NAK and any additional ACK/NAK
protocol characters enabled are still accepted.
* Disable GLS Handshaking

Miscellaneous
³

1

1

6

1

1

0

³

1

1

6

1

0

0

³

1

4

1

4

1

6

³

1

4

1

4

0

6

Enable French PC Term – The scanner
transmits PC type make/break scan codes
instead of ASCII data characters. The scan
codes match a WYSE French PC Term.
* Disable French PC Term
Enable NCR Scanner – Only Commands

* Disable NCR Scanner – Only Commands

10–5

10–6

11
Keyboard
Enable Keyboard Emulation
Load Keyboard Wedge Defaults – Loads the
default settings for keyboard wedge mode.

³

9

9

9

9

9

4

³

5

1

5

5

1

5

3

³

5

1

5

5

1

4

3

Enable Stand-Alone Keyboard Emulation –
Use this with special stand-alone models that are
not cabled for an external keyboard. Scan this
bar code to enable the Stand-Alone Mode. The
scanner will send keyboard “power on”
information and configure hardware to simulate a
constant keyboard connection.
* Enable Keyboard Wedge Emulation – Use this
with an external keyboard. Transmit in wedge
made to allow standard PC keyboards to
communicate when no bar code data is
available.

Country/Scan Code Table Selects
* USA Keyboard
³

4

1

6

2

6

0

³

4

1

6

2

8

0

³

4

1

6

2

5

0

³

4

1

6

2

4

0

³

4

1

6

2

3

0

³

4

1

6

2

2

0

³

4

1

6

2

1

0

Switzerland Keyboard
Spain Keyboard
Italy Keyboard
Germany Keyboard
France Keyboard
UK Keyboard

11–1

Belgium Keyboard
³

4

1

6

2

0

0

³

4

1

6

2

1

0

³

4

1

6

2

7

0

³

4

1

6

2

9

0

³

4

1

Japan Keyboard
0

IBM 4700 Financial Keyboard
Sweden/Finland Keyboard
Slovenian Keyboard
6

2

1

1

0

Keyboard/System Type
* AT Keyboard – Includes IBM PS/2 and
compatible models 50, 55, 60, 80.

³

2

1

6

2

1

5

³

2

1

6

2

0

5

³

2

1

6

2

2

5

³

2

1

6

2

3

5

³

1

1

6

3

0

7

Enable XT Keyboard for Mode 1 – Special
firmware in Voyager.

³

1

1

6

3

1

7

Enable XT Keyboard for Mode 2 – Special
firmware in Voyager.

XT Keyboard – Special firmware in Voyager.

PS/2 Keyboard – Includes IBM PC and
compatible models 30, 70, 8556.
Enable Terminal Keyboard Emulation.

11–2

‘Dumb’ Terminal Selections
Note: The following terminals may require custom cables.
IBM Terminal Keyboards
³

3

1

6

4

0

0

³

3

1

6

4

1

0

³

3

1

6

4

2

0

³

3

1

6

4

3

0

³

3

1

6

4

4

0

³

3

1

6

4

5

0

³

3

1

6

4

6

0

³

3

1

6

4

7

0

³

1

1

6

7

1

4

³

1

1

6

7

0

4

³

1

1

6

7

1

5

³

1

1

6

7

0

5

Reserved Terminal Keyboard #2
Reserved Terminal Keyboard #3
Reserved Terminal Keyboard #4
Reserved Terminal Keyboard #5
Reserved Terminal Keyboard #6
Reserved Terminal Keyboard #7
Reserved Terminal Keyboard #8

Lower Case Lock On – transmit all data as
lower case.
* Lower Case Lock Off

Spanish Keyboard Ñ Substitution – the
following two characters will translate as follows:
# to Ñ and ^ to ñ.
* No Spanish Keyboard Ñ Substitution

11–3

Special Keyboard Features
Transmit Make Code Only – Not available on
all models.

³

1

1

6

3

1

1

³

1

1

6

3

0

1

* Transmit Make/Break Code – Not available on
all models.

³

1

1

6

3

1

0

* Transmit FOH Break Code – The scanner will
transmit the FOH in the break-code sequence.

³

1

1

6

3

0

0

³

1

1

6

3

1

5

³

1

1

6

3

0

5

³

1

1

6

2

1

7

³

1

1

6

2

0

7

Do Not Transmit FOH Break Code

Transmit Cleanup Bit – Use for certain NEC
computers.
* Do Not Transmit Cleanup Bit

Enable Alt-Mode – See Enable ALT-Mode
(Normal) for description.
* Disable Alt-Mode – Caution: If host software
application uses the right Alt key as a “Hot” key,
Alt-mode must be disabled.

† These settings only apply if the Alt-Mode (shown above) is enabled.
†

³

1

1

6

7

0

6

³

1

1

6

7

1

6

* Enable Alt-Mode (Normal)
The scanner will duplicate the following keyboard
sequence; Hold down the Alt key and Type the
three digit decimal number that corresponds to
the appropriate character.
†

11–4

Enable Alt-Mode (Advanced)
The scanner will duplicate the following keyboard
sequence; Hold down the Alt key and Type the
four digit decimal number that corresponds to the
appropriate character.

³

1

1

6

2

1

4

³

1

1

6

2

0

4

³

1

1

6

2

1

4

³

1

1

6

2

0

4

³

1

1

6

3

1

6

³

1

1

6

3

0

6

³

1

1

6

4

1

0

³

1

1

6

4

0

0

³

1

1

6

3

0

3

³

1

1

6

3

1

3

³

1

1

6

3

0

4

³

1

1

6

3

1

4

Enable Auto Detect Mode (AT/PS2) –
Automatically detects caps lock status.
* Disable Auto Detect Mode (AT/PS2)

Enable Caps Lock (XT)

* Disable Caps Lock (XT)
Send Numbers as Keypad Data – All data is
sent as if it has been entered on a keypad.
* Send Numbers as Normal Data

Enable Reserved Feature

* Disable Reserved Feature

* Use Extended ASCII To Send Extended Key
Codes – Use extended ASCII characters to send
PC keyboard keys e.g., F1, F2.
Use Extended ASCII Characters as Extended
ASCII> – Transmit extended ASCII codes via
Alt Mode.
* Character KB Inhibit

Message KB Inhibit

11–5

Enable Right Alt Key Sequencing
³

1

1

6

3

0

2

³

1

1

6

3

1

2

³

1

1

6

4

1

3

³

1

1

6

4

0

3

Disable Right Alt Key Sequencing

Enable LaCaixa Special Keyboard Prefix &
Suffix Scan Codes
* Disable LaCaixa Special Keyboard Prefix &
Suffix Scan Codes

InterScan Code Delays
³

8

1

³

8

1

³

8

³

11–6

9

1

6

6

6

1

5

5

5

6

8

7

1

5

5

5

0

* InterScan Code Delay 800 msec – The time
specified represents the amount of time between
individual 11-bit scan codes. This parameter may
need to be adjusted for operation with certain PC
keyboard BIOS.

0

0

0

0

0

InterScan Code Delay 7.5 msec – This time
specified represents the amount of time between
individual 9-bit scan codes. This parameter may
need to be adjusted for operation with certain PC
keyboard BIOS.
InterScan Code Delay 15 msec – The time
specified represents the amount of time between
individual 11-bit scan codes. This parameter may
need to be adjusted for operation with certain PC
keyboard BIOS.
~ Variable InterScan Code Delay msec – Refer
to Multi-Code Method on page 1–1. Sets value in
100 microsecond increments.

Control Sets
In general, standard bar code symbologies will only encode the ASCII
character set. Function keys, arrow keys and many other extended keys on an
IBM compatible keyboard do not translate to ASCII characters. One method of
‘bar coding’ the extended keys is to substitute the extended key codes when a
specific ASCII control character is found in the bar code stream. The Control
Sets are specific translations of the ASCII (HEX) set.

Control Set #1
Enable Control Set #1
³

4

1

6

4

8

4

³

4

1

6

4

0

4

* Disable Control Set #1

11–7

ASCII (HEX)

ASCII Control

00H

Null

Numeric Keypad + (Plus)

01H

SOH

Num Lock

02H

STX

Down Arrow

03H

ETX

Numeric Keypad - (Minus)

04H

EOT

Insert

05h

ENQ

Delete

06H

ACK

System Request

07H

BEL



(Right Arrow)

08H

BS



(Left Arrow)

11–8

Extended Key

09H

TAB

0AH

LF

Tab
Caps Lock

0BH

VT

Shift Tab

0CH

FF

Left Alt

0DH

CR

Enter

0EH

SO

Left Control

OFH

SI

Up Arrow

10H

DLE

F1

11H

DC1

F2

12H

DC2

F3

13H

DC3

F4

14H

DC4

F5

15H

NAK

F6

16H

SYN

F7

17H

ETB

F8

18H

CAN

F9

19H

EM

F10

1AH

SUB

Home
Esc

1BH

ESC

1CH

FS

Page Up

1DH

GS

Page Down

1EH

RS

Print Screen

1FH

US

End

12
OCIA
³

4

1

5

5

4

4

³

9

9

9

9

9

3

³

2

1

7

7

0

6

³

2

1

7

7

1

6

³

2

1

7

7

3

6

³

2

1

7

7

2

6

³

1

1

7

7

0

5

³

1

1

7

7

1

5

Enable OCIA Mode – Select this option if
communications requires OCIA (Optically
Coupled Interface Adapter). The host clocks this
serial interface.
Load OCIA Defaults

Enable DTS/Siemens

* Enable DTS/Nixdorf

Enable NCR-S

Enable NCR-F

* Transmit character count with non-UPC codes
while transmitting in OCIA NCR-S mode
Do not Transmit character count with non-UPC
codes while transmitting in OCIA NCR-S mode

12–1

12–2

13
Light Pen Parameters
³

4

1

5

5

2

4

³

1

1

6

9

1

7

³

1

1

6

9

0

7

³

1

1

6

9

1

6

³

1

1

6

9

0

6

³

1

1

6

9

1

5

³

1

1

6

9

0

5

³

1

1

6

9

1

1

³

1

1

6

9

0

1

³

1

1

6

9

1

0

³

1

1

6

9

0

0

Enable Light Pen Mode – Select this option if
the scanner will be used in place of a light pen.
It provides light pen emulation of each bar code
scanned.
* Bars High

Spaces High

Transmit as Code 39 – All bar codes will be
decoded then transmitted as Code 39 bar codes.
* Transmit as Scanned – All bar codes will be
decoded and transmitted in that symbology.
Poll Light Pen Source – The scanner waits for
an active source voltage before transmitting data.

* Do Not Poll Light Pen Source

Enable Inverted IDLE/Extra Toggle – The
scanner beeps and toggles the light pen data line
with an extra data pulse to condition the decoder.
* Disable Inverted IDLE/Extra Toggle

Enable Pre-Transmit Toggle of RTS Line

* Disable Pre-Transmit Toggle of RTS Line

13–1

Set Narrow Element Width
³

1

1

6

9

1

2

10x Narrow Element Border – Allows the
transmission of Light Pen/Wand emulation using
a 10x border.

³

1

1

6

9

0

2

* 50x Narrow Element Border – Allows the
transmission of Light Pen/Wand emulation using
a 50x border.

³

8

1

6

8

1

6

3

0

* 1 ms Narrow Element Width – Allows the
transmission of Light Pen/ Wand emulation at
1ms Narrow Element width.
60 µs Narrow Element Width

³

8

1

6

8

1

0

0

³

8

1

6

8

1

6

0

³

8

1

6

8

8

2

0

³

9

1

6

8

0

0

100 µs Narrow Element Width

500 µs Narrow Element Width

13–2

~ Variable Narrow Element Width – Sets the
minimum x-dimension in 6 µs increments. Scan
this code followed by a 3-digit code byte
sequence (on page 16–1).

14

IBM® 46xx Configuration
IBM Port
³

4

1

5

5

0

4

³

9

9

9

9

9

5

³

3

1

7

2

5

0

³

3

1

7

2

6

0

³

3

1

7

2

7

0

³

3

1

7

2

3

0

³

1

1

7

2

0

6

³

1

1

7

2

1

6

Enable RS485 Communication – For RS485
communications. Not all scanners support this
interface. The correct interface board is required.
Load RS485 Defaults – Load default format
settings for the RS485 systems.
IBM Port 17B 3687-2 In Counter
IBM Port 5B 1520 HH Laser
* IBM Port 9B 4500 CCD HH BCR1
IBM Port 9B 4501 CCD HH BCR2
* Disable CTS select of RS485 vs RS232
Enable RS485 transmit when CTS = -12 Volt &
RS232 transmit when CTS = +12 Volt

IBM Reserved Codes
IBM Reserved #1
³

3

1

7

2

0

0

³

3

1

7

2

1

0

³

3

1

7

2

2

0

³

3

1

7

2

4

0

IBM Reserved #2
IBM Reserved #3
IBM Reserved #5

14–1

14–2

15
USB
Enable USB Interface♦
³

4

1

5

5

1

1

³

9

9

9

9

7

8

4

Enable Low Speed USB Defaults♦
♦ This feature is limited to Honeywell scanners without integrated Low Speed
USB electronics. These bar codes configure the scanner to communicate
via the MX009.

³

9

9

9

9

4

0

Load Integrated Full Speed USB Keyboard
Emulation Defaults

³

9

9

9

9

7

0

Load Integrated Full Speed USB IBM/OEM
Defaults

³

9

9

9

9

3

1

³

3

1

6

4

3

0

³

3

1

³

3

1

6

4

0

1

Load Integrated Low Speed USB OPOS Defaults
Feature is limited to scanners with internal
Low-Speed USB interfaces with specific software
versions.
IBM OEM Scanner 4B00h Hand-Held – Full
Speed USB Only

0

IBM OEM Scanner 4A00h Flat-Bed – Full
Speed USB Only
* Enable USB Keyboard Emulation Mode

6

4

0

0

Note: USB Keyboard Emulation Mode is a factory default. If the Recall

Defaults bar code is scanned while reconfiguring the scanner, the
scanner configuration will revert to the factory default setting
discarding any previous configuration settings for USB Serial
Emulation. To enable the Serial Emulation Mode, rescan the
Bi-Directional or Uni-Directional USB Serial Emulation Mode bar code
on page 15–2.

15–1

³

3

1

6

4

7

0

Enable Uni-Directional USB Serial Emulation
Mode –Supported in Honeywell MS9500,
MS5100 and IS4125 laser-class products.
Note: This bar code enables Bi-Directional USB
Serial Emulation Mode in the Honeywell
®
Focus area-imaging products.

³

3

1

6

4

6

0

³

1

1

7

8

1

7

³

1

1

7

8

0

7

³

1

1

9

8

1

7

³

1

1

9

8

0

7

³

9

9

9

9

7

3

³

9

9

9

9

7

2

³

9

9

9

9

6

7

³

9

9

9

9

6

6

³

1

1

7

8

1

3

³

1

1

7

8

0

3

Enable Bi-Directional USB Serial Emulation
Mode – Supported in Honeywell MS9500,
MS5100 and IS4125 laser-class products.
Note: This configuration code is not supported for
Focus/Imager class products (see note
above).
Enable Bar Code ID
Disable Bar Code ID
Enable USB Reserve Code #1
Disable USB Reserve Code #1
Enable USB Reserve Code #2
Disable USB Reserve Code #2
Sears USB Defaults
Sears Aux Defaults
Enable IBM 1520 Code Flag Emulation –
UPC code IDs and ITF code IDs remain the
same but all other code IDs are transmitted as
Code 39 (IBM OEM Scanner Modes).
Disable IBM 1520 Code Flag Emulation

15–2

16
Code Bytes Usage
The scanner must be in Configuration Mode for the features requiring code
bytes for configuration. The Enter/Exit Configuration Mode bar code must be
scanned before starting the configuration cycle. User configurable prefix/suffix
characters can then be saved by scanning the 3 digit decimal equivalent of the
ASCII character into the appropriate character location with the code byte bar
codes.
Example: To add an Asterisk (*) as a Prefix, scan the bar codes.
1.
2.
3.
4.
5.
6.

Enter/Exit Configuration Mode
(3 beeps)
Configurable Prefix #1
(1 beep)
Code Byte 0
(1 beep)
Code Byte 4
(2 beeps)
Code Byte 2
(3 beeps)
Enter/Exit Configuration Mode
(3 beeps)

Code Bytes 0–9
Code Byte 0
³

0

³

1

³

2

³

3

³

4

³

5

³

6

³

7

Code Byte 1

Code Byte 2

Code Byte 3

Code Byte 4

Code Byte 5
Code Byte 6
Code Byte 7

16–1

Code Byte 8
³

8

³

9

Code Byte 9

Reserved Codes
³

9

9

9

9

8

8

³

9

9

9

9

8

7

~ Enable Reserved Code – Contact Honeywell for
information about this feature.
~ Disable Reserved Code

Code Type Table
Code Byte

16–2

Code Types

004

UPC-A

002

UPC-E

003

EAN-8

005

EAN-13

080

Code 39

081

Codabar

082

Interleaved 2 of 5

083

Code 128

084

Code 93

091

MSI Plessey

092

Code 11

093

Airline 2 of 5 (15 digits)

094

Matrix 2 of 5

095

Telepen

096

UK Plessey

099

TRI-OPTIC

098

Standard 2 of 5

097

Airline (13 digits)

ASCII Reference Table
HEX Value

Decimal Value/
Code Byte Value

Character

Control
Keyboard Eqv

00
01

000

NUL

@

001

SOH

A

02

002

STX

B

03

003

ETX

C

04

004

EOT

D

05

005

ENQ

E

06

006

ACK

F

07

007

BEL

G

08

008

BS

H

09

009

HT

I

0A

010

LF

J

0B

011

VT

K

0C

012

FF

L

0D

013

CR

M

0E

014

SO

N

0F

015

SI

0

10

016

DLE

P

11

017

DC1

Q

12

018

DC2

R

13

019

DC3

S

14

020

DC4

T

15

021

NAK

U

16

022

SYN

V

17

023

ETB

W

18

024

CAN

X

19

025

EM

Y

1A

026

SUB

Z

1B

027

ESC

[

1C

028

FS

\

16–3

HEX Value

Decimal Value/
Code Byte Value

Character

1D

029

GS

^

1E

030

RS

_

1F

031

US

space,blank

20

032

SP

21

033

!

22

034

“

23

035

#

24

036

$

25

037

%

26

038

&

27

039

‘

28

040

(

16–4

Control
Keyboard Eqv

apostrophe

29

041

)

2A

042

*

2B

043

+

2C

044

,

comma

2D

045

-

minus
period

2E

046

.

2F

047

/

30

048

0

number zero

31

049

1

number one

32

050

2

33

051

3

34

052

4

35

053

5

36

054

6

37

055

7

38

056

8

39

057

9

3A

058

:

3B

059

;

HEX Value

Decimal Value/
Code Byte Value

Character

Control Keyboard
Eqv

3C

060

<

less than

3D

061

=

3E

062

>

3F

063

?

40

064

@

41

065

A

42

066

B

43

067

C

44

068

D

45

069

E

46

070

F

47

071

G

48

072

H

49

073

I

4A

074

J

4B

075

K

4C

076

L

4D

077

M

4E

078

N

4F

079

O

50

080

P

51

081

Q

52

082

R

53

083

S

54

084

T

55

085

U

56

086

V

57

087

W

58

088

X

59

089

Y

greater than
shift P

letter l

letter O

16–5

HEX Value

Decimal Value/
Code Byte Value

Character

5A

090

Z

5B

091

[

16–6

Control Keyboard
Eqv
shift K

5C

092

\

shift L

5D

093

]

shift M

5E

094

^

à,shift N

5F

095

_

♣, shift 0, underscore

60

096

‘

accent grave

61

097

a

62

098

b

63

099

c

64

100

d

65

101

e

66

102

f

67

103

g

68

104

h

69

105

I

6A

106

j

6B

107

k

6C

108

l

6D

109

m

6E

110

n

6F

111

o

70

112

p

71

113

q

72

114

r

73

115

s

74

116

t

75

117

u

76

118

v

77

119

w

78

120

x

HEX Value

Decimal Value/
Code Byte Value

Character

79
7A
7B
7C
7D
7E
7F

121
122
123
124
125
126
127

y
z
{
|
}
~
DEL

Control
Keyboard Eqv

vertical slash
alt mode
(alt mode)
delete, rubout

Extended Key Code Reference Table
Key




Insert
Delete
Home
End
Page Up
Page Down
Right Alt
Right Ctrl
Reserved
Reserved
Numeric Keypad Enter
Numeric Keypad/
F1
F2
F3
F4
F5
F6
F7

At Scan PS2 Scan
Code
Code
75H
72H
74H
6BH
70H
71H
6CH
69H
7DH
7AH
11H
14H
00H
00H
5AH
4AH
05H
06H
04H
0CH
03H
0BH
83H

48H
50H
4DH
4BH
52H
53H
47H
4FH
49H
51H
38H
1DH
00H
00H
1CH
35H
3BH
3CH
3DH
3EH
3FH
40H
41H

3151

Prefix/Suffix Value
Hex = Decimal

63H
60H
6AH
61H
67H
64H
6EH
00H
00H
00H
00H
39H
00H
00H
79H
00H
07H
0FH
17H
1FH
27H
2FH
37H

80H = 128
81H = 129
82H = 130
83H = 131
84H = 132
85H = 133
86H = 134
87H = 135
88H = 136
89H = 137
8AH = 138
8BH = 139
8CH = 140
8DH – 141
8EH = 142
8FH = 143
90H = 144
91H = 145
92H = 146
93H = 147
94H = 148
95H = 149
96H = 150
16–7

Key

At Scan PS2 Scan
Code
Code

F8
0AH
F9
01H
F10
09H
F11
78H
F12
07H
Numeric +
79H
Numeric 7BH
Numeric *
7CH
Caps Lock
58H
Num Lock
77H
Left alt
11H
Left Ctrl
14H
Left Shift
12H
Right Shift
59H
Print Screen
Multiple
Tab
ODH
Shift Tab
8DH
Enter
5AH
ESC
76H
Left ALT Make
11H
Left ALT Break
11H
Left CTRL Make
14H
Left CTRL Break
14H
*Left ALT + 1 character 11H
*Left Crtl + 1 character
14H
*Send
Clear
Jump
Send Line
Erase EOF
Send - Make Only

42H
43H
44H
57H
58H
4EH
4AH
37H
3AH
45H
38H
1DH
2AH
36H
00H
OFH
8FH
1CH
01H
36H
B6H
1DH
9DH
36H
1DH

3151

Prefix/Suffix Value
Hex = Decimal

3FH
47H
4FH
56H
5EH
00H
7CH
00H
14H
00H
00H
11H
12H
59H
00H
0DH
65H
5AH
08H
00H
00H
00H
00H
00H
00H
58H
6FH
76H
7EH
6DH
58H

97H = 151
98H = 152
99H = 153
9AH = 154
9BH = 155
9CH = 156
9DH = 157
9EH = 158
9FH = 159
A0H = 160
A1H = 161
A2H = 162
A3H = 163
A4H = 164
A5H = 165
A6H = 166
A7H = 167
A8H = 168
A9H = 169
AAH = 170
ABH = 171
ACH = 172
ADH = 173
AEH = 174
AFH = 175
C0H = 192
C1H = 193
C2H = 194
C3H = 195
C4H = 196
C5H = 197

* Example:
1st Configurable Prefix = 174
2nd Configurable Prefix = 065
Scanner will transmit  “A” 
16–8

17
MS9520 Voyager® and
MS9540 VoyagerCG® Series
Activation Range
Use these bar codes to select infrared (IR) sensor activation range for sensing
when objects are placed in the scan field.
* Long Range In Stand
³

1

1

8

7

0

5

³

1

1

8

7

1

5

³

1

1

8

7

0

1

³

1

1

8

7

1

1

Short Range In Stand
* Long Range Out of Stand
Short Range Out of Stand

Stand Scan Modes
³

1

2

0

1

1

7

³

1

2

0

1

0

7

Short Scan In Stand – While scanning in the
stand, the unit will only accept bar codes within
the short IR range.
* Normal Scan In Stand

CodeGate Status
Use the following bar codes to control button functions.
Note: The following functions are not supported by all versions of the MS5145.
CodeGate Active in Stand
³

1

1

8

7

0

7

³

1

1

8

7

1

7

* CodeGate Inactive in Stand

17–1

* CodeGate Active Out of Stand
³

1

1

8

7

1

3

³

1

1

8

7

0

3

CodeGate Inactive Out of Stand

Laser/Scan Modes
* Normal Scan – The laser turns on after the IR
senses a bar code. The laser remains on for
approximately 3 to 10 seconds.

³

4

1

8

3

0

4

³

4

1

8

3

2

4

³

4

³

4

1

8

3

4

4

Custom (One Shot) Scan – The laser turns off
after a good decode.

³

4

1

8

3

5

4

Enable Manual Activation Mode – The laser
activates when the CodeGate button is pressed.

³

1

2

0

0

0

0

³

1

2

0

0

1

0

1

8

3

3

Blinky Scan – Laser turns on after the IR senses
a bar code. The laser will blink on/off for
approximately 60 seconds.
Continuous Blinky Scan – The laser blinks
continuously and the IR is inactive. This feature
is not available for the VoyagerPDF series.

4

* Normal Timeout (Button Act)

0.5 Second Timeout (Button Act)

17–2

Same Symbol Time Outs
If using an MS5145 Eclipse, the MS9524 or MS9544 VoyagerPDF, go to
page 7–3.
No Same Symbol Time Out
³

8

1

8

9

0

0

³

8

1

8

9

1

0

³

8

1

8

9

2

0

³

8

1

8

9

3

0

³

8

1

8

9

4

0

³

8

1

8

9

5

0

³

8

1

8

9

6

0

³

8

1

8

9

7

0

³

1

1

8

9

1

7

1000 msec Same Symbol Time Out

* 875 msec Same Symbol Time Out

750 msec Same Symbol Time Out

625 msec Same Symbol Time Out

500 msec Same Symbol Time Out

375 msec Same Symbol Time Out

250 msec Same Symbol Time Out

Infinite Same Symbol Time Out

17–3

MS9520-00 and MS9540-00 Laser Emulation Mode
The MS9520-00 and MS9540-00 leave the factory with Laser Emulation
interface enabled.
If you recall defaults while re-configuring your scanner, scan the following bar
code to re-enable the Laser Emulation interface. The scanner you are using
must be labeled as an MS9520-00 or MS9540-00 to support this feature.
Enable HH Laser Emulation
³

9

9

9

9

7

9

If host controlled laser emulation is required scan the following bar code after
scanning the Enable HH Laser Emulation bar code.
Enable Host Controlled Laser Emulation
³

1

1

7

0

1

0

Normal Laser Emulation Motor Idle State
³

1

1

7

0

0

1

³

1

1

7

0

1

1

Reverse Laser Emulation Motor Idle State

17–4

18
MS9524 and MS9544
VoyagerPDF® Series
* Enable PDF
³

1

0

0

0

1

0

³

1

0

0

0

0

0

³

1

1

5

0

1

0

³

1

1

5

0

0

0

Disable PDF
* Enable Audible Indicator
Disable Audible Indicator

PDF CodeGate Status
Enable PDF CodeGate in Stand
³

1

1

8

7

1

6

³

1

1

8

7

0

6

³

1

1

8

7

1

4

³

1

1

8

7

0

4

* Disable PDF CodeGate in Stand
Enable PDF CodeGate Out of Stand
* Disable PDF CodeGate Out of Stand

MicroPDF and Composite Code Handling
³

1

0

0

4

1

7

³

1

0

0

4

0

7

³

1

1

5

0

0

7

Enable MicroPDF – Allows composite
symbologies to be scanned (PDF 417 is enabled
by default).
* Disable MicroPDF

* Enabe GS1 DataBar 2D Linkage – Transmits the
1D GS1 DataBar without scanning the 2D portion.

18–1

Disable GS1 DataBar 2D Linkage
³

1

1

5

0

1

7

³

1

1

5

0

1

6

³

1

1

5

0

0

6

³

1

1

5

0

0

5

³

1

1

5

0

1

5

³

1

1

5

0

0

4

³

1

1

5

0

1

4

³

1

1

5

0

0

3

³

1

1

5

0

1

3

³

1

1

5

0

0

2

* Normal Composite Xmit – Always transmit the
1D and 2D constituent composite components
separately.

³

1

1

5

0

1

2

Xmit Composite Separately – Transmit the
1D and 2D constituent composite components
separately.

³

1

1

5

0

1

1

Enable EAN-128 Emulation – Utilize the
UCC/EAN128 protocol for transmission
purposes.

³

1

1

5

0

0

1

Enable UPC/EAN Linkage – Link UPC/EAN
symbols with a 2D composite constituent then
transmit.
* Disable UPC/EAN Linkage
* Enable Code 128 Linkage – Transmit the 1D
Code 128 without scanning the 2D portion.
Disable Code 128 Linkage
* Enable PDF 1D Linkage – Transmit the 2D
portion of the PDF-417 without scanning the 1D
portion.
Disable PDF 1D Linkage

* Enable UPDF 1D Linkage – Transmit the 2D
portion of microPDF without scanning the 1D
portion.
Disable UPDF 1D Linkage

* Disable EAN-128 Emulation
For Same Symbol Time Out information refer to page 7–3.
18–2

19
MS9535 VoyagerBT

®
®

The MS9535 can act as a client to other devices equipped with Bluetooth
wireless technology. If the device’s address is a 12-digit hex value that does
NOT start with a FNC3 (e.g., 000CA700118) the user must first scan the Get
BT Address bar code (below), and then scan the device’s address bar code.
Get BT Address
³

0

0

0

C

A

7

F

F

F

F

F

F

Scan the Provide BT Service bar code (below) to place the MS9535 into
service mode. In this mode, other Bluetooth wireless technology enabled
devices can initiate a connection to the scanner.
Provide BT Service
³

³

1

2

4

3

1

6

³

1

2

4

3

0

6

³

8

4

0

9

0

0

³

9

9

9

9

1

8

0

0

0

C

A

7

0

0

0

0

0

0

BT PIN Required – The MS9535 will require a
valid PIN when Bluetooth wireless technology
enabled devices try to initiate a communication
connection.
* BT Pin Not Required
BT PIN Default Value – The default PIN ID will be
the last 4 digits of the serial number.
Next Bar Code is BT Pin ID – When scanned this
feature enables the scanner to store the next
scanned bar code as the PIN ID. The PIN ID must
be numeric and be 4 to 16 characters in length.
The BT PIN Required bar code (shown above)
must also be scanned to utilize the PIN ID.
Enable BT Address Transmission

³

9

9

8

0

4

5

³

9

9

8

0

4

4

³

8

1

9

5

6

0

Enable BT Software Version Transmission

Sleep in 1 Minute – The scanner will go into
sleep (power save) mode after the laser has
been off for 1 minute.

19–1

³

8

1

9

5

1

2

0

Sleep in 2 Minutes – The scanner will go into
sleep mode after the laser has been off for
2 minutes.

³

8

1

9

5

3

0

0

Sleep in 5 Minutes – The scanner will go into
sleep mode after the laser has been off for
5 minutes.

³

8

1

9

5

6

0

0

Sleep in 10 Minutes – The scanner will go into
sleep mode after the laser has been off for
10 minutes.

³

1

2

3

9

0

7

³

1

2

3

9

1

7

³

1

2

3

7

1

1

³

1

2

3

7

0

1

³

1

2

3

7

0

2

³

1

2

3

7

1

2

³

1

2

3

7

0

7

³

1

2

3

7

1

7

³

1

2

3

7

1

6

³

1

2

3

7

0

6

* Enable Scanning in Cradle

Disable Scanning in Cradle
Enable In Stand Error Audio Indicator –
Activates an audible indicator the when the
scanner is in the stand/charging cradle but is not
making contact via the battery terminal contacts.
* Disable In Stand Error Indicator

* Enable Cradle LED

Disable Cradle LED
Enable Range Gate – Store scanned bar codes
into RAM if the wireless connection has been
interrupted.
* Disable Range Gate
Enable BT Test – The cradle will display certain
connection information (KO, OK, etc.).
Note: Do not enable this feature unless instructed
to by a Honeywell representative.
* Disable BT Test

19–2

20
MS9535-5M VoyagerBT
³

1

2

3

9

1

0

Enable Inventory Mode – Bar code data that is
scanned is stored in the scanner’s expanded
memory base. The data will be transmitted when
the scanner is placed back into its BT cradle.
Note: A special beep will sound when a bar code
is scanned but not stored due to a full a
memory base. The scanner must be placed
in the BT cradle to empty the memory.
* Disable Inventory Mode

³

1

2

3

9

0

0

³

1

2

3

9

0

3

³

1

2

3

9

1

3

³

1

2

3

9

0

1

³

1

2

3

9

1

1

³

1

2

3

9

1

2

³

1

2

3

9

0

2

³

1

2

3

9

0

4

³

1

2

3

9

1

4

* Auto Cradle Transmit – All bar code data is
automatically transmitted when the scanner is
placed into the BT cradle.
No Cradle Transmit – The scanner will not
automatically transmit bar code data when placed
in the BT cradle.
* Transmit Inventory FIFO – Data is transmitted
on a first-in, first-out basis.
Transmit Inventory LIFO – Data is transmitted on
a last-in, first-out basis.
Enable Inventory Beep – A beep will sound as
each bar code is transmitted. A special audible
indicator will sound on completion of data transfer.
* Disable Inventory Beep

* No Transmit/Entry Counter

Transmit/Entry Counter – Optional field
transmitted with the bar code data that is a count
of the number of transmissions used to transmit
the entire buffer.

20–1

³

9

9

8

0

4

9

³

1

2

5

6

1

2

³

1

2

5

6

0

2

³

9

9

8

0

4

8

Clear Inventory Records – Will clear all stored
bar code data in memory.
Enable Auto Clear Records – Will automatically
clear the stored records in the inventory buffer
after transmission of the records stored.
* Maintain Records

Delete Last Record – Deletes the last bar code
stored.. When the Transmit Quantity Field has
been enabled, each scanned quantity code is a
unique field. If the delete last record bar code is
scanned, it will remove the last quantity code
scanned.
Example:
If a quantity of 103 (Quantity 1, Quantity 0,
and Quantity 3) was scanned but a quantity
of 10 was desired.
1.
2.

³

9

9

8

0

5

0

³

9

9

8

0

5

1

³

1

2

3

9

1

5

³

1

2

3

9

0

5

Scan the delete last record bar code.
The Quantity 3 code will be deleted and
a quantity of 10 will be stored.

Transmit All Records – Transmits all stored data
records.
Transmit Record Counters – Will transmit the
number of records and the number of bar codes
currently stored as a 5-digit number separated by
a space.
Transmit Quantity Field – Adds an additional
quantity field for the last item (bar code) scanned.
Once enabled the user is able to enter a numerical
quantity from 1 to 9999 for the last item (bar code)
scanned (see Inventory Quantity Bar Codes,
on page 20–3).
* Don’t Transmit Quantity Field

20–2

Inventory Quantity Bar Codes**
The following inventory quantity bar codes will enable the user to enter a
quantity from 1 to 9999 for the last item (bar code) scanned. The item’s bar
code data will be retransmitted as many times as the quantity indicates.
Example:

1.
2.
3.
4.

Scan the item’s bar code (ie. ABCD)
Scan the Quantity 1 bar code
Scan the Quantity 0 bar code
The ABCD bar code will be transmitted 10 times
Quantity 0

³

Q

0

³

Q

1

³

Q

2

³

Q

3

³

Q

4

³

Q

5

³

Q

6

³

Q

7

³

Q

8

³

Q

9

Quantity 1

Quantity 2

Quantity 3

Quantity 4

Quantity 5

Quantity 6

Quantity 7

Quantity 8

Quantity 9
** Transmit Quantity Field must be enabled (on page 20–2) for this feature.

20–3

20–4

21
IS4125 and IS4225 Scan Engines
Disable Old Serial Program
³

1

2

0

3

1

5

³

1

2

0

3

0

5

³

1

2

0

3

1

1

³

1

2

0

3

1

2

³

1

2

0

3

1

3

1

1

9

8

Enable Old Serial Program

Enable TTL UART

Enable Non Buffered TTL UART

Enable Detect and Notify Mode

³

8

4

6

6

0

0

Cunningham Defaults – Scan this code
followed by Recall Defaults code to enable and
load Cunningham defaults.
Recall Defaults

³

9

9

9

9

For Same Symbol Time Out information, see page 7–3.

21–1

21–2

22
IS4823 and IS4825 Scan Engines
Operating Modes
Activation Modes
³

4

1

8

3

0

4

³

1

1

8

1

1

0

³

1

2

0

3

1

6

³

1

1

7

4

1

5

³

9

1

7

5

0

0

* Activate Scanning with the External Trigger –
An external I/O pin is used to enable the scanning
cycle. A High-to-Low transition on the I/O signal is
used to activate scanning. The signal must be
deactivated (HIGH) and re-activated for
subsequent scanning cycles. The scanning cycle
is terminated based on the default period of time
(2 seconds), a variable period of time, when the
I/O signal is deactivated (Low-to-High), or when a
bar code is scanned and transmitted.
Activate Scanning on Receipt of the 
Character – A received  character initiates
the scanning cycle. The scanning cycle is
terminated based on the default period of time
(2 seconds), variable laser timeout selected, or
when a bar code is scanned and transmitted.
Activate Scanning Using D/E – A received ‘E’
character initiates the scanning cycle. The
scanning cycle is terminated based on the default
period of time (2 seconds), variable laser timeout
selected, or receipt of a ‘D’ or when a bar code is
scanned and transmitted.
Activate Scanning with Address – A
configurable address character is used to initiate
scanning. The scanning cycle is terminated based
on the default period of time (2 seconds), variable
laser timeout selected, or when a bar code is
scanned and transmitted.
~ Address Value – Use this bar code with a code
byte sequence (on page 16–1) that represents
the desired character to be used to initiate
scanning. An ASCII reference table is available
on page 16–3.

22–1

Activation Mode Features
~ Variable Laser-On Time Out – Scan this bar
code with a code byte sequence (on page 16–1)
that represents the desired time out increment.
The configurable time increment (1-second
increments) selected is the scanning laser-on
time.

³

9

1

9

6

0

0

³

1

2

0

3

1

4

Allow Full Laser-On Cycle – The laser stays on
for a full cycle even when a bar code is scanned
and transmitted.

³

4

1

8

3

2

4

Blinky Mode – The laser turns on after the
selected activation trigger is detected. The laser
will blink on/off for approximately 30 seconds.

³

1

1

8

1

1

1

³

1

1

8

1

0

1

³

1

1

8

3

1

1

³

1

1

8

3

0

1

³

1

1

9

9

1

7

³

1

2

0

3

0

3

Transmit a NO READ Message on Laser Time
Out – If the scanning cycle terminates without
scanning a bar code during the cycle, a NO READ
message is transmitted with the termination of the
scanning cycle.
Do Not Transmit a NO READ Message on Laser
Time Out
Activate the LED during the NO READ
Transmission – The LED is output with the NO
READ message.
Deactivate LED during the NO READ
Transmission

Enable RTS No Read Pulse – A configurable
RTS pulse width transmitted after the NO READ
message has been transmitted.
Disable RTS No Read Pulse

22–2

³

1

2

0

3

1

3

Detect and Notify Mode (Monitor the External
Trigger) – The external I/O pin used in the default
activation mode is monitored during the inactive
laser cycles. An  is transmitted when the I/O
is active and an  when it is inactive. Once
the scanning activation cycle is started, the
external I/O monitoring status is maintained until
the scanning cycle is terminated regardless of the
actual I/O level.

Continuous Blinky Mode
³

4

1

8

3

3

4

0

0

Continuous Blinky Mode – The scanner will
continuously blink on and off, turning the scanning
cycle on and off for all normal scanner operations.
If a bar code is scanned and transmitted, the same
symbol timeout is maintained throughout the cycle
preventing additional scans of the same bar code
when the scanner is in default mode.

Sleep Mode
³

9

1

9

5

~ Sleep Mode – A power saving mode that can
be configured to occur in 1-second increments.
Use this code with a code byte sequence
(on page 16–1) that represents the desired
increment.

22–3

22–4

23
Miscellaneous Features
Custom Defaults
Honeywell manufactures several scanners for OEM applications. These
scanners may use a different set of defaults than Honeywell factory defaults.
Scanning the bar code will reset the default table to Honeywell defaults.

³

8

4

6

6

0

0

³

9

9

9

9

9

8

Enable Factory Defaults – Scan this code
followed by Recall Defaults code to enable and
load Honeywell factory defaults.
Recall Defaults
Ruby Verifone Defaults – Scan this code
followed by Recall Defaults code to enable and
load Ruby Verifone defaults.

³

8

4

6

6

1

2

8

0

³

8

4

6

6

0

0

1

0

RCH – Scan this code followed by Recall
Defaults code to enable and load RCH defaults.

³

8

4

6

6

0

0

2

0

Sanyo – Scan this code followed by Recall
Defaults code to enable and load Sanyo defaults.

³

8

4

6

6

0

0

3

0

Gilbarco – Scan this code followed by Recall
Defaults code to enable and load Gilbarco
defaults.

³

8

4

6

6

0

0

4

0

ALT Defaults – Scan this code followed by
Recall Defaults code to enable and load Alt
defaults.

³

8

4

6

6

0

0

5

0

LaCaixa Custom Keyboard Defaults – Scan
this code followed by Recall Defaults code to
enable and load LaCaixa defaults.

³

8

4

6

6

0

1

2

0

ABACAB Defaults – Scan this code followed by
Recall Defaults code to enable and load
ABACAB defaults.

23–1

Serial Program Mode
For Serial Program Mode, all commands must be framed by an STX (02 Hex)
and ETX (03 Hex).
To recall defaults:
1.

Transmit 999999 through the Serial Port. This will put the
scanner in serial program mode. Scanning will be suspended and the
scanner will respond with an ACK (06 Hex).

2.

Transmit 999998 through the Serial Port. This is the Recall
Defaults bar code in the MetroSelect guide. The scanner will respond with
an ACK (06 Hex).

3.

Transmit 999999 through the Serial Port. This will cause the
scanner to exit program mode and save the new settings. The scanner will
beep 3 times and send an ACK (06 Hex).

If at anytime, the scanner cannot recognize a command, it will respond with a
NAK (15 Hex).

23–2

24
Customer Support
Technical Assistance
If you need assistance installing or troubleshooting your device, please call
your distributor or the nearest technical support office:
North America/Canada
Telephone: (800) 782-4263
E-mail: hsmnasupport@honeywell.com
Latin America
Telephone: (803) 835-8000
Telephone: (800) 782-4263
E-mail: hsmlasupport@honeywell.com
Brazil
Telephone: +55 (11) 5185-8222
Fax: +55 (11) 5185-8225
E-mail: brsuporte@honeywell.com
Mexico
Telephone: 01-800-HONEYWELL (01-800-466-3993)
E-mail: soporte.hsm@honeywell.com
Europe, Middle East, and Africa
Telephone: +31 (0) 40 7999 393
Fax: +31 (0) 40 2425 672
E-mail: hsmeurosupport@honeywell.com
Hong Kong
Telephone: +852-29536436
Fax: +852-2511-3557
E-mail: aptechsupport@honeywell.com
Singapore
Telephone: +65-6842-7155
Fax: +65-6842-7166
E-mail: aptechsupport@honeywell.com
China
Telephone: +86 800 828 2803
Fax: +86-512-6762-2560
E-mail: aptechsupport@honeywell.com
Japan
Telephone: +81-3-3839-8511
Fax: +81-3-3839-8519
E-mail: aptechsupport@honeywell.com
Online Technical Assistance
You can also access technical assistance online at www.honeywellaidc.com.
24–1

Product Service and Repair
Honeywell International Inc. provides service for all its products through
service centers throughout the world. To obtain warranty or non-warranty
service, contact the appropriate location below to obtain a Return Material
Authorization number (RMA #) before returning the product.
North America
Telephone: (800) 782-4263
E-mail: hsmnaservice@honeywell.com
Latin America
Telephone: (803) 835-8000
Telephone: (800) 782-4263
Fax: (239) 263-9689
E-mail: laservice@honeywell.com
Brazil
Telephone: +55 (11) 5185-8222
Fax: +55 (11) 5185-8225
E-mail: brservice@honeywell.com
Mexico
Telephone: 01-800-HONEYWELL (01-800-466-3993)
Fax: +52 (55) 5531-3672
E-mail: mxservice@honeywell.com
Europe, Middle East, and Africa
Telephone: +31 (0) 40 2901 633
Fax: +31 (0) 40 2901 631
E-mail: euroservice@honeywell.com
Hong Kong
Telephone: +852-29536436
Fax: +852-2511-3557
E-mail: apservice@honeywell.com
Singapore
Telephone: +65-6842-7155
Fax: +65-6842-7166
E-mail: apservice@honeywell.com
China
Telephone: +86 800 828 2803
Fax: +86-512-6762-2560
E-mail: apservice@honeywell.com
Japan
Telephone: +81-3-3839-8511
Fax: +81-3-3839-8519
E-mail: apservice@honeywell.com

24–2

Online Product Service and Repair Assistance

You can also access product service and repair assistance online at
www.honeywellaidc.com

24–3

Honeywell Scanning & Mobility
9680 Old Bailes Road
Fort Mill, SC 29707
www.honeywellaidc.com

00-02544 Rev K
2/11



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Copy, Extract, Print high-res
Category                        : Manual
Comments                        : 
Company                         : Metrologic
Create Date                     : 2011:01:28 15:27:51-05:00
Keywords                        : "manual, configuration, barcode, 00-02544"
Manager                         : Dari Buchhofer
Modify Date                     : 2011:02:17 09:54:06-05:00
Source Modified                 : D:20110128181615
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2011:02:17 09:54:06-05:00
Creator Tool                    : Acrobat PDFMaker 9.1 for Word
Document ID                     : uuid:aac6995f-7242-4454-bdb3-c25e87a43fcb
Instance ID                     : uuid:aa34b5eb-949a-4678-a28e-52f09fb24217
Format                          : application/pdf
Title                           : MetroSelect Single-Line Configuration Guide
Description                     : Manual
Creator                         : 
Subject                         : manual, configuration, barcode, 00-02544
Producer                        : Adobe PDF Library 9.0
Headline                        : Manual
Page Layout                     : TwoPageRight
Page Mode                       : UseOutlines
Page Count                      : 116
EXIF Metadata provided by EXIF.tools

Navigation menu