Honeywell T4039A Users Manual 60 2241 T4039A,B,D M,S,V Line Voltage Cooling And Heating Thermostats
2015-01-23
: Honeywell Honeywell-T4039A-Users-Manual-262399 honeywell-t4039a-users-manual-262399 honeywell pdf
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
T4039A,B,D-M,S,V Line Voltage Cooling and Heating-Cooling Thermostats T4039 Thermostats Control Line Voltage Valves of a fan coil unit in cooling, manual changeover heating-cooling, or automatic changeover heating-cooling systems. One or two valves may be controlled directly by the thermostat. The fan switch (where applicable) controls air circulation. ■ 1-, 2-, or 3-speed manual fan control available. ■ Color-coded leadwires. ■ Positive deadspot separates heating-cooling circuits in automatic models. Remote changeover switch is required to separate circuits in manual changeover heating-cooling models. ■ All models can be mounted on standard vertical outlet boxes. Models with manual switching can be mounted on 4 in. square junction boxes or 2ganged outlet boxes. ■ Scale range is approximately 55° F to 95° F [13° to 35° C] in 10° F [6° C] increments from 75° F [24° C] midpoint. Scale is marked COOL-WARM. ■ Adjustable range stops limit temperature adjustment or lock at selected setpoint. ■ Cooling circuit breaks in FAN-OFF position to reduce condensation problems in the fan coil unit. ■ Models available with separate power source for fan and thermostat. CONTENTS Specifications ................................................. 2 Ordering Information ..................................... 2 Installation ..................................................... 5 Operation ....................................................... 8 Checkout ......................................................... 8 J. H. • Rev. 110-92 • ©Honeywell Inc. 1992 • Form Number60-2241—8 60-2241—8 T4039A,B,D-M,S,V SPECIFICATIONS • ORDERING INFORMATION Specifications MODELS: System Cooling Only Cooling Only Heating-Coolingc Heating Coolingc Heating-Coolingc Automatic Heating-Cooling Automatic Heating-Cooling Automatic Heating-Cooling Automatic Heating-Cooling Automatic Heating-Cooling Autoamtic Heating-Cooling Automatic Heating-Cooling Automatic Heating-Cooling Manual Switchinga Off-Onb Hi-Med-Lo Off-Onb — Off-Ond Off-Hi-Lob — Hi-Med-Lo Off-Onb None — Off-Ond Off-Hi-Lob Off-Hi-Lod — Hi-Med-Lob Off-On Hi-Med-Lo Off-Ond Hi-Med-Lo Heat-Off-Coold Hi-Lo Off-Ond ELECTRICAL RATINGS: A. Thermostat (valve load). Model T4039A T4039B T4039D Normal (A) Inrush (B) 120 Vac 0.32 1.00 240 Vac 0.16 0.50 277 Vac 0.14 0.43 B. Fan Switch T4039E T4039F T4039G T4039H T4039J T4039K T4039L Full Load (A) Locked Rotor (A) 120 Vac 5.5 33.0 240 Vac 2.75 16.5 277 Vac 2.4 14.4 10A Resistive at 125 Vac 5A Resistive at 240 Vac 4.2A Resistive at 277 Vac TEMPERATURE SETTING RANGE: Approximately 55° F to 95° F [13° C to 35° C]; marked COOLWARM in 10° F [6° C] increments from 75° F [24° C] midpoint. T4039M T4039S DIFFERENTIAL: Approximately 2° F [1° C] at midscale. On automatic heating-cooling models, the differential from make of one contact to make of the opposite contact is 7° F [4° C] maximum with a positive deadspot. T4039V a See Fig. 4 for arrangements of switches. b OFF breaks cooling circuit and fan circuit. c Remote changeover switch required. d DIMENSIONS: See Figs. 1 and 2. OFF breaks both heating and cooling circuits and fan circuit. Ordering Information When purchasing replacement and modernization products from your TRADELINE® wholesaler or your distributor, refer to the TRADELINE Catalog or price sheets for complete ordering number, or specify— 1. Model number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Home and Building Control Sales Office (check white pages of your phone directly). 2. Home and Building Control Customer Satisfaction Honeywell Inc., 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 (612) 951-1000 In Canada—Honeywell Limited/Honeywell Limitée, 740 Ellesmere Road, Scarborough, Ontario M1P 2V9. International Sales and Service offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 2 T4039A,B,D-M,S,V SPECIFICATIONS FINISH: Silver bronze. T4039M is available in white. also mount on a standard vertical outlet box if local codes permit. See Fig. 3. MOUNTING: Models without manual switching mount on standard vertical outlet boxes. Models with manual switching mount on 4-in. square junction boxes or 2-ganged outlet boxes. Manual switching models may UNDERWRITERS LABORATORIES, INC. LISTED: File No. E4436, Vol. 2, dated 3-19-73; Guide No. XAPX. Fig. 1—Mounting dimensions in in. [mm] of T4039 models with manual switching. Fig. 2—Mounting dimensions in in. [mm] of T4039 models without manual switching. 3 60-2241—8 T4039A,B,D-M,S,V SPECIFICATIONS Fig. 3—Mounting T4039. 4 T4039A,B,D-M,S,V INSTALLATION Installation MOUNTING Models without manual switching mount on standard vertical outlet boxes. Models with manual switching mount on 4-in. square junction boxes or 2-ganged outlet boxes. Manual switching models can also mount on standard vertical outlet boxes if local electrical codes permit. Mount thermostat on side wall about 5 ft. [1.5 m] above the floor. Do not mount where thermostat can be affected by drafts, radiant heat from the sun or other sources of heat. Use Allen wrench to open cover and mount according to Fig. 3. Two mounting screws are provided. WHEN INSTALLING THIS PRODUCT… 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. After the installation is complete, check out product operation as provided in these instructions. WIRING Disconnect power supply before beginning installation to avoid electrical shock or equipment damage. All wiring must comply with local codes and ordinances. Internal schematic and external connections for the T4039 are shown in Fig. 4. Use solderless connectors or other approved methods to wire thermostat into the system. Six-inch color-coded leadwires are provided. CAUTION Disconnect power supply to prevent electrical shock or equipment damage. Before mounting, be sure to remove cardboard shipping inserts that protect the contacts. 1. Remove T4039 cover by loosening the cover screw with Allen wrench. 2. Open the cardboard inside cover by pressing inward on the left side to release latch. Do not remove this cover. 3. Carefully remove the shipping inserts from around the snap contacts. 4. Check contact operation before mounting device. SETTING The T4039 temperature scale is marked COOL-WARM with approximate scale divisions of 10° F from 75° F [24° C] midpoint. The range is approximately 55° F to 95° F [13° C to 35° C]. Set lever at desired temperature. To adjust the temperature setpoint range stops, Fig. 3, locate stops at the desired temperature range setpoint and insert. 5 60-2241—8 T4039A,B,D-M,S,V INSTALLATION Fig. 4—Internal schmeatics and external connections for T4039 Thermostats. BLUE TO FAN T4039A RISE 1 TO COOLING CONTROL RED HI OFF T4039F MED ON YELLOW L1 (HOT) LO 3 ORANGE L1 (HOT) LO BLUE MED TAN YELLOW HI TO FAN SPEED CONTROL RISE RISE OFF TO HEATING CONTROL BROWN 1 ON HI T4039B MED LO L1 (HOT) TO COOLING CONTROL BLUE TO FAN SPEED CONTROL TAN YELLOW RISE 1 ORANGE RED OFF T4039G RED ON TO COOLING CONTROL ORANGE RED TO COOLING CONTROL RISE L1 (HOT) BROWN ORANGE TO HEATING CONTROL L1 (HOT) T4039D BLUE TO FAN RED TO COOLING CONTROL T4039H RISE RISE BLUE BROWN TO HEATING CONTROL TO FAN RED OFF TO COOLING CONTROL RISE 2 ON BROWN YELLOW L1 (HOT) ORANGE L1 (HOT) TO HEATING CONTROL OFF 3 2 ON YELLOW ORANGE L1 (HOT) 3 L1 (HOT) T4039E RED TO COOLING CONTROL RISE RISE OFF 1 BROWN HI ORANGE TO HEATING CONTROL L1 (HOT) LO LO HI OFF BREAKS COOLING AND FAN CIRCUITS. OFF BREAKS HEATING, COOLING AND FAN CIRCUITS. 3 SEPARATE POWER SOURCE FOR THERMOSTAT AND FAN. CONNECT ORANGE AND YELLOW FOR SINGLE POWER SOURCE IF NEEDED. M5353 BLUE YELLOW 1 2 TO FAN SPEED CONTROL 6 T4039A,B,D-M,S,V INSTALLATION Fig. 4—Internal schmeatics and external connections for T4039 Thermostats (Continued). RED 1 TO COOLING CONTROL RISE OFF BROWN HI ORANGE T4039J T4039M TO HEATING CONTROL L1 (HOT) LO MED BLACK HI YELLOW LO BLUE TO FAN SPEED CONTROL HI BLUE LO HI YELLOW TO FAN SPEED CONTROL MED LO RED TO COOLING CONTROL BROWN TO HEATING CONTROL RISE OFF 2 TYPICAL T4039K RED ON 4 ORANGE L1 (HOT) TO COOLING CONTROL RISE BROWN 2 TO HEATING CONTROL OFF HI ORANGE L1 (HOT) T4039S LO LO HI BLUE TO FAN SPEED CONTROL YELLOW MED TAN HI YELLOW LO BLUE TO FAN SPEED CONTROL HI MED LO BROWN HI T4039L MED LO 2 LO BLUE MED TAN HI YELLOW TO HEATING CONTROL HEAT RISE OFF ORANGE COOL TO FAN SPEED CONTROL L1 (HOT) RED TO COOLING CONTROL RISE 1 OFF ON BROWN ORANGE RED TO HEATING CONTROL L1 (HOT) T4039V TO COOLING CONTROL 1 OFF BREAKS COOLING AND FAN CIRCUITS. 2 OFF BREAKS HEATING, COOLING AND FAN CIRCUITS. 3 SEPARATE POWER SOURCE FOR THERMOSTAT AND FAN. CONNECT ORANGE AND YELLOW FOR SINGLE POWER SOURCE IF NEEDED. 4 THE WIRE COLORS OF THE T4039K1024 MODEL DIFFER FROM THE TYPICAL T4039K MODELS AS FOLLOWS: TYPICAL YELLOW BLUE RED BROWN ORANGE T4039K T4039K1024 BROWN RED BLUE YELLOW BLACK LO BROWN HI RED TO FAN SPEED CONTROL HI LO BLUE TO COOLING CONTROL RISE 2 YELLOW OFF ON BLACK TO HEATING CONTROL L1 (HOT) M5352 7 60-2241—8 Operation In heating applications, as the temperature drops, the thermostat heating contacts make to open a valve that allows hot water to flow through the coil. On select models, the speed at which the heat is circulated is controlled manually by the fan switch. In cooling applications, as the temperature rises, the thermostat cooling contacts close to open a valve that allows cold water to flow through the coil. Cooling mechanism will not operate if manual switch is in the OFF position. Models T4039D,H,K,M,S,V will also turn off the heating valve when the manual switch is in OFF. In manual changeover heating-cooling models, the thermostat must be used with a remote changeover switch or control to select the proper heating or cooling cycle for the thermostat. CALIBRATION The T4039 is accurately calibrated at the factory under controlled conditions. Do not attempt to field calibrate this device. Checkout Check the T4039 before leaving the installation. Raise the temperature setting to start the heating cycle or lower Home and Building Control Honeywell International, Inc. 1985 Douglas Drive North Golden Valley, MN 55422 the setting to start the cooling cycle. Check both cycles on heating-cooling models. Home and Building Control Honeywell Limited—Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 8
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Fill forms, Extract, Assemble, Print high-res Page Count : 8 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:9609d8bd-0553-4756-88c3-85b1c947347c Keywords : Producer : Acrobat Distiller 4.0 for Macintosh Modify Date : 2004:11:08 10:34:16-06:00 Create Date : 2004:11:08 10:53:07Z Creator Tool : Adobe PageMaker 6.5 Metadata Date : 2004:11:08 10:34:16-06:00 Document ID : uuid:e1b6af67-db77-4cd4-b44f-3ea34084a0d7 Format : application/pdf Title : 60-2241 - T4039A,B,D-M,S,V Line Voltage Cooling and Heating-Cooling Thermostats Creator : Honeywell Technical Communications Description : Product Data Author : Honeywell Technical Communications Subject : Product DataEXIF Metadata provided by EXIF.tools