Honeywell Xenon 1900 Users Manual 1900/1902 Area Imaging Scanner User’s Guide
1900 to the manual b508d26e-2e89-40a3-8fdb-e8efaab3227d
xenon-ug
2015-01-23
: Honeywell Honeywell-Xenon-1900-Users-Manual-261780 honeywell-xenon-1900-users-manual-261780 honeywell pdf
Open the PDF directly: View PDF .
Page Count: 312
Download | |
Open PDF In Browser | View PDF |
Xenon™ 1900/1902 Area-Imaging Scanner User’s Guide ™ Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII. HII shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of HII. © 2010-2011 Honeywell International Inc. All rights reserved. Other product names or marks mentioned in this document may be trademarks or registered trademarks of other companies and are the property of their respective owners. Web Address: www.honeywellaidc.com Microsoft® Windows®, Windows NT®, Windows 2000, Windows ME, Windows XP, and the Windows logo are trademarks or registered trademarks of Microsoft Corporation. The Bluetooth® word mark and logos are owned by Bluetooth SIG, Inc. Other product names or marks mentioned in this document may be trademarks or registered trademarks of other companies and are the property of their respective owners. Product Agency Compliance - Xenon 1900 USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio or television technician for help. If necessary, the user should consult the dealer or an experienced radio/ television technician for additional suggestions. The user may find the following booklet helpful: “Something About Interference.” This is available at FCC local regional offices. Honeywell is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Honeywell. The correction is the responsibility of the user. Use only shielded data cables with this system. This unit has been tested with cables less than 3 meters. Cables greater than 3 meters may not meet class B performance. Caution: Any changes or modifications made to this equipment not expressly approved by Honeywell may void the FCC authorization to operate this equipment. UL Statement UL listed: UL60950-1. Canada Industry Canada ICES-003 This Class B digital apparatus complies with Canadian ICES-003. Operation is subject to the following conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. Conformité à la règlementation canadienne Cet appareil numérique de la Classe A est conforme à la norme NMB-003 du Canada. Son fonctionnement est assujetti aux conditions suivantes : 1. Cet appareil ne doit pas causer de brouillage préjudiciable. 2. Cet appareil doit pouvoir accepter tout brouillage reçu, y compris le brouillage pouvant causer un fonctionnement indésirable. cUL Statement cUL listed: CSA C22.2 No.60950-1-07. Europe The CE marking indicates compliance to 2004/108/EC EMC Directive with Standards EN55022 CLASS B, EN55024, EN61000-3-2, EN61000-3-3. In addition, complies to 2006/95/EC Low Voltage Directive, when shipped with recommended power supply. For further information please contact: Honeywell Imaging & Mobility Europe BV Nijverheidsweg 9-13 5627 BT Eindhoven The Netherlands Honeywell International Inc. shall not be liable for use of our product with equipment (i.e., power supplies, personal computers, etc.) that is not CE marked and does not comply with the Low Voltage Directive. Waste Electrical and Electronic Equipment Information Honeywell complies with Directive 2002/96/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 27 January 2003 on waste electrical and electronic equipment (WEEE). This product has required the extraction and use of natural resources for its production. It may contain hazardous substances that could impact health and the environment, if not properly disposed. In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources, we encourage you to use the appropriate take-back systems for product disposal. Those systems will reuse or recycle most of the materials of the product you are disposing in a sound way. The crossed out wheeled bin symbol informs you that the product should not be disposed of along with municipal waste and invites you to use the appropriate separate take-back systems for product disposal. If you need more information on the collection, reuse, and recycling systems, please contact your local or regional waste administration. You may also contact your supplier for more information on the environmental performances of this product. Germany If your product is marked with the GS symbol, then the product has been issued a GS certificate showing compliance to EN 60950-1, Second Edition. Australia/NZ C-Tick Statement Conforms to AS/NZS 3548 EMC requirement Mexico Conforms to NOM-019. Japan Russia Gost-R certificate South Korea This product meets Korean agency approval. Taiwan If the following label is attached to your product, the product meets Taiwan agency approval: BSMI Standard: CNS13438, CNS14336 依據標準 : CNS13438, CNS14336 International LED Safety Statement LEDs have been tested and classified as “EXEMPT RISK GROUP” to the standard: IEC 62471:2006. CB Scheme Certified to CB Scheme IEC 60950-1, Second Edition. Laser Safety Statement If the following label is attached to your product, it indicates the product contains a laser engine or laser aimer: LASER LIGHT. DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT 1.0 mW MAX OUTPUT: 650nM IEC 60825-1 Ed 2 (2007). Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007. This device has been tested in accordance with and complies with IEC60825-1 ed2.0 and 21 CFR 1040.10 and 1040.11, except for deviations pursuant to Laser Notice No.50, dated June 24, 2007. LASER LIGHT, DO NOT STARE INTO BEAM, CLASS 2 LASER PRODUCT, 1.0 mW MAX OUTPUT: 630-650nM. Caution - use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Patents For patent information, please refer to www.honeywellaidc.com/patents. Solids and Water Protection The Xenon 1900 has a rating of IP41, immunity of foreign particles and dripping water. Warning ! To reduce the possibility of heat-related injuries, avoid touching sections of the scanner that feel warm. Product Agency Compliance - Xenon 1902 and CCB01-010BT Base USA FCC Part 15 Subpart C This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. Caution: Any changes or modifications made to this equipment not expressly approved by Honeywell may void the FCC authorization to operate this equipment. Use only shielded data cables with this system. This unit has been tested with cables less than 3 meters. Cables greater than 3 meters may not meet class B performance. UL Statement UL listed: UL60950-1. Canada Industry Canada This device complies with Canadian RSS-210. Operation is subject to the following conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation. Conformité à la règlementation canadienne Cet appareil ISM est conforme à la norme CNR-210 du Canada. Son fonctionnement est assujetti aux conditions suivantes : 1. Cet appareil ne doit pas causer de brouillage préjudiciable. 2. Cet appareil doit pouvoir accepter tout brouillage reçu, y compris le brouillage pouvant causer un fonctionnement indésirable. C-UL Statement C-UL listed: CSA C22.2 No.60950-1-07 for I.T.E product safety. Europe The CE marking on the product indicates that this device is in conformity with all essential requirements of the 1999/5/EC R&TTE Directive. In addition, complies to 2006/95/EC Low Voltage Directive, when shipped with recommended power supply. For further information, contact: Honeywell Imaging & Mobility Europe BV International Inc. Nijverheidsweg 9-13 5627 BT Eindhoven The Netherlands Honeywell shall not be liable for use of our product with equipment (i.e., power supplies, personal computers, etc.) that is not CE marked and does not comply with the Low Voltage Directive. This equipment is intended for use throughout the European Community and has been assessed to the following standards: EN 300 328 EN 301 489-1 EN 301 489-17 EN60950-1 Waste Electrical and Electronic Equipment Information Honeywell complies with Directive 2002/96/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL on waste electrical and electronic equipment (WEEE). This product has required the extraction and use of natural resources for its production. It may contain hazardous substances that could impact health and the environment, if not properly disposed. In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources, we encourage you to use the appropriate take-back systems for product disposal. Those systems will reuse or recycle most of the materials of the product you are disposing in a sound way. The crossed out wheeled bin symbol informs you that the product should not be disposed of along with municipal waste and invites you to use the appropriate separate take-back systems for product disposal. If you need more information on the collection, reuse, and recycling systems, contact your local or regional waste administration. You may also contact your supplier for more information on the environmental performances of this product. Germany If your product is marked with the GS symbol, then the product has been issued a GS certificate showing compliance to EN 60950-1, Second Edition. Australia/NZ C-Tick Statement Conforms to AS/NZS 3548 EMC requirements. Brazil This product is approved by Anatel, according to the procedures regulated by Resolution No. 242/2000 and meets the technical requirements applied. Este produto está homologado pela ANATEL, de acordo com os procedimentos regulamentados pela Resolução No. 242/2000 e atende aos requisitos técnicos aplicados. Para maiores informações, consulte o site da ANATEL – www.anatel.gov.br Modelo: Xenon 1902 2876-10-6583 (01)07898927490072 " Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário." China SRRC Radio Certificate. CCC safety (CCB01-101BT base only) Japan Complies with Technical Regulations Conformity Certification of Specified Radio equipment. Korea This product meets Korean agency approval. Mexico Conforms to NOM-019. Russia Taiwan If the following label is attached to your product, the product meets Taiwan agency approval: BSMI Standard: CNS13438, CNS14336 (Xenon 1902 only) 依據標準 : CNS13438, CNS14336 NCC standard: Low power frequency electric machineries technical standard: LP0002 International LED Safety Statement LEDs have been tested and classified as “EXEMPT RISK GROUP” to the standard: IEC 62471:2006. Radio Technology Class II CB Scheme Certified to CB Scheme IEC 60950-1, Second Edition. Laser Safety Statement If the following label is attached to your product, it indicates the product contains a laser engine or laser aimer: LASER LIGHT. DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT 1.0 mW MAX OUTPUT: 650nM IEC 60825-1 Ed 2 (2007). Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007. This device has been tested in accordance with and complies with IEC60825-1 ed2.0 and 21 CFR 1040.10 and 1040.11, except for deviations pursuant to Laser Notice No.50, dated June 24, 2007. LASER LIGHT, DO NOT STARE INTO BEAM, CLASS 2 LASER PRODUCT, 1.0 mW MAX OUTPUT: 630-650nM. Caution - use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Solids and Water Protection The Xenon 1902 has a rating of IP41, immunity of foreign particles and dripping water. Patents For patent information, please refer to www.honeywellaidc.com/patents. Warning ! To reduce the possibility of heat-related injuries, avoid touching sections of the scanner that feel warm. Required Safety Labels Scanner Illumination output Item Number, Serial Number and Revision Information location Compliance Label location CCB01-010BT Base Item Number, Serial Number and Revision Information location Compliance Label location Table of Contents Chapter 1 - Getting Started About This Manual ...................................................... 1-1 Unpacking Your Device............................................... 1-1 Connecting the Device ................................................ 1-2 Connecting with USB ............................................ 1-2 Connecting with Keyboard Wedge ........................ 1-3 Connecting with RS232 Serial Port ....................... 1-5 Connecting with RS485......................................... 1-6 Reading Techniques ................................................... 1-8 Menu Bar Code Security Settings ............................... 1-8 Setting Custom Defaults ............................................. 1-9 Resetting the Custom Defaults ................................... 1-9 Resetting the Factory Defaults .................................. 1-10 Chapter 2 - Programming the Interface Introduction ................................................................. 2-1 Programming the Interface - Plug and Play ................ 2-1 Keyboard Wedge................................................... 2-1 Laptop Direct Connect........................................... 2-1 RS232 Serial Port.................................................. 2-2 RS485 ................................................................... 2-2 RS485 Packet Mode ............................................. 2-3 USB IBM SurePos................................................. 2-4 USB PC or Macintosh Keyboard ........................... 2-4 USB HID................................................................ 2-5 USB Serial............................................................. 2-5 Verifone® Ruby Terminal Default Settings ............ 2-6 Gilbarco® Terminal Default Settings ..................... 2-7 Honeywell Bioptic Aux Port Configuration............. 2-7 Datalogic™ Magellan© Bioptic Aux Port Configuration.................................................... 2-7 NCR Bioptic Aux Port Configuration...................... 2-8 Wincor Nixdorf Terminal Default Settings ............. 2-8 i Wincor Nixdorf Beetle™ Terminal Default Settings ................................................ 2-9 Keyboard Country Layout ..........................................2-10 Keyboard Style ..........................................................2-17 Keyboard Conversion ................................................2-18 Control Character Output...........................................2-19 Keyboard Modifiers....................................................2-19 RS232 Baud Rate......................................................2-22 RS232 Word Length: Data Bits, Stop Bits, and Parity ................................................................2-23 RS232 Receiver Time-Out.........................................2-24 RS232 Handshaking..................................................2-24 RS232 Timeout .................................................... 2-25 XON/XOFF .......................................................... 2-25 ACK/NAK ............................................................. 2-25 Scanner to Bioptic Communication............................2-26 Scanner-Bioptic Packet Mode ............................. 2-26 Scanner-Bioptic ACK/NAK Mode......................... 2-27 Scanner-Bioptic ACK/NAK Timeout..................... 2-27 Chapter 3 - Cordless System Operation How the Cordless Charge Base /Access Point Works .................................................3-1 Linking the Scanner to a Charge Base ........................3-1 Linking the Scanner to an Access Point ......................3-2 Communication Between the Cordless System and the Host ..............................................................3-2 RF (Radio Frequency) Module Operation....................3-3 System Conditions.......................................................3-3 Linking Process ..................................................... 3-3 Scanner Is Out of Range ....................................... 3-4 Scanner Is Moved Back Into Range ...................... 3-4 Out of Range and Back into Range with Batch Mode On ......................................... 3-4 Page Button .................................................................3-4 About the Battery .........................................................3-4 ii Charging Information............................................. 3-5 Battery Recommendations .................................... 3-5 Proper Disposal of the Battery .............................. 3-6 Beeper and LED Sequences and Meaning ................. 3-6 Scanner LED Sequences and Meaning ................ 3-7 Base/Access Point LED Sequences and Meaning ........................................................... 3-7 Base Power Communication Indicator .................. 3-8 Reset Scanner ............................................................ 3-8 Scanning While in Base Cradle................................... 3-8 Paging ......................................................................... 3-9 Paging Mode ......................................................... 3-9 Paging Pitch ......................................................... 3-9 Error Indicators............................................................ 3-9 Beeper Pitch - Base Error ..................................... 3-9 Number of Beeps - Base Error ............................ 3-10 Scanner Report ......................................................... 3-10 Scanner Address....................................................... 3-11 Base or Access Point Address .................................. 3-11 Scanner Modes ......................................................... 3-11 Charge Only Mode .............................................. 3-11 Linked Modes ...................................................... 3-12 Unlinking the Scanner ............................................... 3-13 Override Locked Scanner.................................... 3-13 Out-of-Range Alarm .................................................. 3-13 Alarm Sound Type............................................... 3-14 Flexible Power Management..................................... 3-15 Batch Mode ............................................................... 3-16 Batch Mode Beep................................................ 3-17 Batch Mode Storage............................................ 3-17 Batch Mode Quantity........................................... 3-18 Batch Mode Output Order ................................... 3-20 Delete Last Code................................................. 3-20 Clear All Codes ................................................... 3-20 Transmit Records to Host.................................... 3-21 Batch Mode Transmit Delay ................................ 3-21 Multiple Scanner Operation....................................... 3-21 iii Scanner Name...........................................................3-22 Application Work Groups ...........................................3-24 Application Work Group Selection ....................... 3-25 Resetting the Factory Defaults: All Application Work Groups....................................3-25 Resetting the Custom Defaults: All Application Work Groups....................................3-26 Using the Scanner with Bluetooth Devices................3-26 PCs/Laptops ........................................................ 3-26 PDAs/Mobility Systems Devices .......................... 3-27 Changing the Scanner’s Bluetooth PIN Code...... 3-27 Minimizing Bluetooth/ISM Band Network Activity ......3-27 Auto Reconnect Mode ......................................... 3-28 Maximum Link Attempts ...................................... 3-29 Relink Time-Out ................................................... 3-30 Bluetooth/ISM Network Activity Examples ........... 3-30 Host Command Acknowledgment .............................3-31 Chapter 4 - Input/Output Settings Power Up Beeper ........................................................4-1 Beep on BEL Character...............................................4-1 Trigger Click.................................................................4-2 Good Read and Error Indicators..................................4-2 Beeper – Good Read ............................................. 4-2 Beeper Volume – Good Read................................ 4-3 Beeper Pitch – Good Read .................................... 4-3 Beeper Pitch – Error .............................................. 4-4 Beeper Duration – Good Read .............................. 4-4 LED – Good Read ................................................. 4-4 Number of Beeps – Good Read ............................ 4-5 Number of Beeps – Error ....................................... 4-5 Good Read Delay .................................................. 4-6 User-Specified Good Read Delay.......................... 4-6 Manual Trigger Modes.................................................4-6 Serial Trigger Mode .....................................................4-7 Read Time-Out ...................................................... 4-7 iv Scanner Power Time-Out Timer............................ 4-7 Presentation Mode ...................................................... 4-9 Presentation LED Behavior after Decode ............. 4-9 Presentation Sensitivity ......................................... 4-9 Presentation Centering........................................ 4-10 In-Stand Sensor Mode .............................................. 4-11 CodeGate® ................................................................ 4-12 Streaming Presentation™ Mode ............................... 4-12 Streaming Presentation In-Stand Programming ................................................. 4-13 Mobile Phone Read Mode......................................... 4-13 Image Snap and Ship................................................ 4-14 Hands Free Time-Out ............................................... 4-14 Reread Delay ............................................................ 4-14 User-Specified Reread Delay.................................... 4-15 Illumination Lights ..................................................... 4-15 Aimer Delay............................................................... 4-16 User-Specified Aimer Delay ................................ 4-16 Scanner Time-Out ..................................................... 4-16 Aimer Mode ............................................................... 4-17 Centering................................................................... 4-17 Preferred Symbology ................................................ 4-19 High Priority Symbology ...................................... 4-20 Low Priority Symbology....................................... 4-20 Preferred Symbology Time-out ........................... 4-20 Preferred Symbology Default .............................. 4-21 Output Sequence Overview ...................................... 4-21 Require Output Sequence................................... 4-21 Output Sequence Editor ...................................... 4-21 To Add an Output Sequence............................... 4-22 Other Programming Selections ........................... 4-22 Output Sequence Editor ...................................... 4-24 Partial Sequence ................................................. 4-24 Require Output Sequence................................... 4-25 Multiple Symbols ....................................................... 4-25 No Read .................................................................... 4-26 Video Reverse........................................................... 4-26 v Working Orientation ...................................................4-27 Chapter 5 - Data Editing Prefix/Suffix Overview..................................................5-1 To Add a Prefix or Suffix: ....................................... 5-1 To Clear One or All Prefixes or Suffixes ................ 5-2 To Add a Carriage Return Suffix to All Symbologies............................................ 5-3 Prefix Selections ..........................................................5-3 Suffix Selections ..........................................................5-4 Function Code Transmit ..............................................5-4 Intercharacter, Interfunction, and Intermessage Delays..........................................5-4 Intercharacter Delay .............................................. 5-5 User Specified Intercharacter Delay ...................... 5-5 Interfunction Delay ................................................. 5-6 Intermessage Delay ............................................... 5-6 Chapter 6 - Data Formatting Data Format Editor Introduction...................................6-1 Add a Data Format ......................................................6-1 Other Programming Selections.............................. 6-3 Terminal ID Table ........................................................6-4 Data Format Editor Commands ...................................6-4 Move Commands................................................... 6-6 Search Commands ................................................ 6-6 Miscellaneous Commands..................................... 6-8 Data Formatter.............................................................6-9 Data Format Non-Match Error Tone .................... 6-10 Primary/Alternate Data Formats ................................6-11 Single Scan Data Format Change ....................... 6-11 Chapter 7 - Symbologies All Symbologies ...........................................................7-2 Message Length Description .......................................7-2 vi Codabar ...................................................................... 7-3 Codabar Concatenation ........................................ 7-4 Code 39....................................................................... 7-6 Code 32 Pharmaceutical (PARAF)........................ 7-8 Full ASCII .............................................................. 7-9 Code 39 Code Page.............................................. 7-9 Interleaved 2 of 5 ...................................................... 7-10 NEC 2 of 5................................................................. 7-12 Code 93..................................................................... 7-14 Code 93 Code Page............................................ 7-15 Straight 2 of 5 Industrial (three-bar start/stop) .......... 7-16 Straight 2 of 5 IATA (two-bar start/stop).................... 7-17 Matrix 2 of 5 .............................................................. 7-18 Code 11..................................................................... 7-19 Code 128................................................................... 7-20 ISBT 128 Concatenation ..................................... 7-20 Code 128 Code Page.......................................... 7-22 GS1-128 .................................................................... 7-23 Telepen ..................................................................... 7-24 UPC-A ....................................................................... 7-25 UPC-A/EAN-13 with Extended Coupon Code .................................. 7-27 Coupon GS1 DataBar Output ................................... 7-28 UPC-E0 ..................................................................... 7-28 UPC-E1 ..................................................................... 7-31 EAN/JAN-13 .............................................................. 7-31 ISBN Translate .................................................... 7-33 EAN/JAN-8 ................................................................ 7-34 MSI ............................................................................ 7-36 GS1 DataBar Omnidirectional ................................... 7-38 GS1 DataBar Limited ................................................ 7-38 GS1 DataBar Expanded............................................ 7-39 Trioptic Code ............................................................. 7-40 Codablock A .............................................................. 7-40 Codablock F .............................................................. 7-42 PDF417 ..................................................................... 7-43 MicroPDF417 ............................................................ 7-44 vii GS1 Composite Codes ..............................................7-45 UPC/EAN Version................................................ 7-45 GS1 Emulation...........................................................7-46 TCIF Linked Code 39 (TLC39) ..................................7-47 QR Code....................................................................7-47 QR Code Page .................................................... 7-48 Data Matrix ................................................................7-49 Data Matrix Code Page ....................................... 7-49 MaxiCode...................................................................7-51 Aztec Code ................................................................7-52 Aztec Code Page ................................................. 7-53 Chinese Sensible (Han Xin) Code .............................7-54 Postal Codes - 2D......................................................7-55 Single 2D Postal Codes: ...................................... 7-55 Combination 2D Postal Codes:............................ 7-56 Postal Codes - Linear ................................................7-59 China Post (Hong Kong 2 of 5) ............................ 7-59 Korea Post ........................................................... 7-61 Chapter 8 - Imaging Commands Single-Use Basis .........................................................8-1 Command Syntax ........................................................8-1 Image Snap - IMGSNP ................................................8-2 IMGSNP Modifiers ................................................. 8-2 Image Ship - IMGSHP .................................................8-5 IMGSHP Modifiers ................................................. 8-5 Intelligent Signature Capture - IMGBOX....................8-14 Signature Capture Optimize ................................ 8-14 IMGBOX Modifiers ............................................... 8-15 RF Default Imaging Device........................................8-19 Chapter 9 - Interface Keys Keyboard Function Relationships ................................9-1 Supported Interface Keys ............................................9-3 viii Chapter 10 - Utilities To Add a Test Code I.D. Prefix to All Symbologies ........................................................... 10-1 Show Decoder Revision ............................................ 10-1 Show Scan Driver Revision....................................... 10-1 Show Software Revision ........................................... 10-1 Show Data Format .................................................... 10-2 Test Menu ................................................................. 10-2 TotalFreedom ............................................................ 10-2 Application Plug-Ins (Apps) ....................................... 10-3 EZConfig Introduction ............................................... 10-3 Installing EZConfig from the Web........................ 10-4 Chapter 11 - Serial Programming Commands Conventions .............................................................. 11-1 Menu Command Syntax............................................ 11-1 Query Commands ..................................................... 11-2 Responses .......................................................... 11-3 Trigger Commands ................................................... 11-4 Resetting the Custom Defaults ................................. 11-4 Menu Commands ...................................................... 11-5 Chapter 12 - Product Specifications 1900 Scanner Product Specifications ....................... 12-1 1902 Scanner Product Specifications ....................... 12-2 CCB01-010BT Charge Base Product Specifications ............................................ 12-3 CCB01-010BT Charge Base Mounting ..................... 12-4 Standard Cable Pinouts ............................................ 12-5 Keyboard Wedge................................................. 12-5 Serial Output ...................................................... 12-6 RS485 Output ..................................................... 12-7 USB ..................................................................... 12-8 ix Chapter 13 - Maintenance Repairs ......................................................................13-1 Maintenance ..............................................................13-1 Cleaning the Scanner .......................................... 13-1 Cleaning the Window ........................................... 13-1 Health Care Housing ........................................... 13-1 Inspecting Cords and Connectors ....................... 13-2 Replacing Cables in Corded Scanners......................13-2 Replacing an Interface Cable .............................. 13-3 Replacing Cables and Batteries in Cordless Systems................................................13-3 Replacing an Interface Cable in a Base .............. 13-3 Changing a scanner Battery ................................ 13-4 Troubleshooting a Xenon Scanner ............................13-4 Troubleshooting a Cordless System..........................13-5 Troubleshooting a Base ....................................... 13-5 Troubleshooting a Cordless Scanner .................. 13-6 Chapter 14 - Customer Support Appendix A - Reference Charts Symbology Chart ........................................................ A-1 ASCII Conversion Chart (Code Page 1252) ............... A-4 Code Page Mapping of Printed Bar Codes................. A-6 Unicode Key Maps...................................................... A-8 x 1 Getting Started About This Manual This User’s Guide provides installation and programming instructions for the Xenon™ 1900 and 1902 area-imaging scanners. Product specifications, dimensions, warranty, and customer support information are also included. Honeywell bar code scanners are factory programmed for the most common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide. An asterisk (*) next to an option indicates the default setting. Unpacking Your Device After you open the shipping carton containing the product, take the following steps: • Check for damage during shipment. Report damage immediately to the carrier who delivered the carton. • Make sure the items in the carton match your order. • Save the shipping container for later storage or shipping. 1-1 Connecting the Device Connecting with USB A scanner or a cordless base can be connected to the USB port of a computer. 1. Connect the appropriate interface cable to the device first, then to the computer. Corded Scanner USB Connection: Cordless Base USB Connection: 1-2 2. Make sure the cables are secured in the wireways in the bottom of the cordless base and that the base sits flat on a horizontal surface. 3. The scanner beeps. 4. Verify the scanner or cordless base operation by scanning a bar code from the Sample Symbols in the back of this manual. The unit defaults to a USB PC Keyboard. Refer to page 2-4 for other USB terminal settings. For additional USB programming and technical information, refer to “USB Application Note,” available at www.honeywellaidc.com. Connecting with Keyboard Wedge A scanner or cordless base can be connected between the keyboard and PC as a “keyboard wedge,” plugged into the serial port, or connected to a portable data terminal in wand emulation or non decoded output mode. The following is an example of a keyboard wedge connection: 1. Turn off power and disconnect the keyboard cable from the back of the terminal/computer. 2. Connect the appropriate interface cable to the device and to the terminal/computer. Corded Scanner Keyboard Wedge Connection: 1-3 Cordless Base Keyboard Wedge Connection: 3. Make sure the cables are secured in the wireways in the bottom of the cordless base and that the base sits flat on a horizontal surface. 4. Turn the terminal/computer power back on. The scanner beeps. 5. Verify the scanner or cordless base operation by scanning a bar code from the Sample Symbols in the back of this manual. The scanner beeps once. The unit defaults to an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard. A carriage return (CR) suffix is added to bar code data. 1-4 Connecting with RS232 Serial Port 1. Turn off power to the terminal/computer. 2. Connect the appropriate interface cable to the scanner. Note: For the scanner or cordless base to work properly, you must have the correct cable for your type of terminal/computer. Corded Scanner RS232 Serial Port Connection: Cordless Base RS232 Serial Port Connection: 1-5 3. Make sure the cables are secured in the wireways in the bottom of the cordless base and that the base sits flat on a horizontal surface. 4. Plug the serial connector into the serial port on your computer. Tighten the two screws to secure the connector to the port. 5. Once the scanner or cordless base has been fully connected, power up the computer. This interface programs 115,200 baud, 8 data bits, no parity, and 1 stop bit. Connecting with RS485 A scanner or cordless base can be connected for an IBM POS terminal interface. 1. Connect the appropriate interface cable to the device, then to the computer. Corded Scanner RS485 Connection: 1-6 Cordless Base RS485 Connection: 2. Make sure the cables are secured in the wireways in the bottom of the cordless base and that the base sits flat on a horizontal surface. 3. Turn the terminal/computer power back on. The scanner beeps. 4. Verify the scanner or cordless base operation by scanning a bar code from the Sample Symbols in the back of this manual. The scanner beeps once. For further RS485 settings, refer to RS485, page 2-2. 1-7 Reading Techniques The scanner has a view finder that projects a bright red aiming beam that corresponds to the scanner’s horizontal field of view. The aiming beam should be centered over the bar code, but it can be positioned in any direction for a good read. Linear bar code 2D Matrix symbol The aiming beam is smaller when the scanner is closer to the code and larger when it is farther from the code. Symbologies with smaller bars or elements (mil size) should be read closer to the unit. Symbologies with larger bars or elements (mil size) should be read farther from the unit. To read single or multiple symbols (on a page or on an object), hold the scanner at an appropriate distance from the target, pull the trigger, and center the aiming beam on the symbol. If the code being scanned is highly reflective (e.g., laminated), it may be necessary to tilt the code up 15° to 18° to prevent unwanted reflection. Menu Bar Code Security Settings Honeywell scanners are programmed by scanning menu bar codes or by sending serial commands to the scanner. If you want to restrict the ability to scan menu codes, you can use the Menu Bar Code Security settings. Please contact the nearest technical support office (see Technical Assistance on page 14-1) for further information. 1-8 Setting Custom Defaults You have the ability to create a set of menu commands as your own, custom defaults. To do so, scan the Set Custom Defaults bar code below before each menu command or sequence you want saved. If your command requires scanning numeric codes from the back cover, then a Save code, that entire sequence will be saved to your custom defaults. Scan the Set Custom Defaults code again before the next command you want saved to your custom defaults. When you have entered all the commands you want to save for your custom defaults, scan the Save Custom Defaults bar code. Set Custom Defaults Save Custom Defaults Note: If using a cordless system, scanning the Save Defaults bar code also causes both the scanner and the base or Access Point to perform a reset and become unlinked. The scanner must be placed in its base to reestablish the link before any setup codes are entered. If using an Access Point, the linking bar code must be scanned. See Cordless System Operation beginning on page 3-1 for additional information. You may have a series of custom settings and want to correct a single setting. To do so, just scan the new setting to overwrite the old one. For example, if you had previously saved the setting for Beeper Volume at Low to your custom defaults, and decide you want the beeper volume set to High, just scan the Set Custom Defaults bar code, then scan the Beeper Volume High menu code, and then Save Custom Defaults. The rest of the custom defaults will remain, but the beeper volume settiing will be updated. Resetting the Custom Defaults If you want the custom default settings restored to your scanner, scan the Activate Custom Defaults bar code below. This is the recommended default bar code for most users. It resets the scanner to the custom default settings. If 1-9 there are no custom defaults, it will reset the scanner to the factory default settings. Any settings that have not been specified through the custom defaults will be defaulted to the factory default settings. Activate Custom Defaults Note: If using a cordless system, scanning this bar code also causes both the scanner and the base or Access Point to perform a reset and become unlinked. The scanner must be placed in its base to re-establish the link. If using an Access Point, the linking bar code must be scanned. See Cordless System Operation beginning on page 3-1 for additional information. Resetting the Factory Defaults ! This selection erases all your settings and resets the scanner to the original factory defaults. It also disables all plugins. If you aren’t sure what programming options are in your scanner, or you’ve changed some options and want to restore the scanner to factory default settings, first scan the Remove Custom Defaults bar code, then scan Activate Defaults. This resets the scanner to the factory default settings. Remove Custom Defaults Activate Defaults Note: If using a cordless system, scanning the Activate Defaults bar code also causes both the scanner and the base or Access Point to perform a reset and become unlinked. The scanner must be placed in its base to reestablish the link before any setup codes are entered. If using an Access Point, the linking bar code must be scanned. See Cordless System Operation beginning on page 3-1 for additional information. The Menu Commands, beginning on page 11-5 list the factory default settings for each of the commands (indicated by an asterisk (*) on the programming pages). 1 - 10 2 Programming the Interface Introduction This chapter describes how to program your system for the desired interface. Programming the Interface - Plug and Play Plug and Play bar codes provide instant scanner set up for commonly used interfaces. Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect. Keyboard Wedge If you want your system programmed for an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard, scan the bar code below. Keyboard wedge is the default interface. Note: The following bar code also programs a carriage return (CR) suffix. IBM PC AT and Compatibles with CR suffix Laptop Direct Connect For most laptops, scanning the Laptop Direct Connect bar code allows operation of the scanner in parallel with the integral keyboard. The following Laptop Direct Connect bar code also programs a carriage return (CR) suffix and turns on Emulate External Keyboard (page 2-18). Laptop Direct Connect with CR suffix 2-1 RS232 Serial Port The RS232 Interface bar code is used when connecting to the serial port of a PC or terminal. The following RS232 Interface bar code also programs a carriage return (CR) and a line feed (LF) suffix, baud rate, and data format as indicated below. It also changes the trigger mode to manual. Option Setting Baud Rate Data Format 115,200 bps 8 data bits, no parity bit, 1 stop bit RS232 Interface RS485 Scan one of the following “Plug and Play” codes to program the scanner for an IBM POS terminal interface. Note: After scanning one of these codes, you must power cycle the cash register. IBM Port 5B Interface IBM Port 9B HHBCR-1 Interface IBM Port 17 Interface IBM Port 9B HHBCR-2 Interface 2-2 Each bar code above also programs the following suffixes for each symbology: Symbology Suffix Symbology Suffix EAN 8 EAN 13 UPC A UPC E 0C 16 0D 0A Code 39 Interleaved 2 of 5 Code 128 * Code 128 ** MaxiCode 00 00 00 00 00 0A 0D 0A 18 2F 0B 0B 0B 0B 0B * Suffixes programmed for Code 128 with IBM 4683 Port 5B, IBM 4683 Port 9B HHBCR-1, and IBM 4683 Port 17 Interfaces **Suffixes programmed for Code 128 with IBM 4683 Port 9 HHBCR-2 Interface RS485 Packet Mode The following selection allows you to break up large bar code data into smaller packets on an IBM POS terminal. To break up large bar codes into small packets, scan the Packet Mode On bar code below. Scan the Packet Mode Off bar code if you want large bar code data to be sent to the host in a single chunk. Default = Packet Mode Off. * Packet Mode Off Packet Mode On RS485 Packet Length If you are using Packet mode, you can specify the size of the data “packet” that is sent to the host. Scan the Packet Length bar code, then then the packet size (from 20 - 256) from the Programming Chart inside the back cover of this manual, then Save. Default = 40. Packet Length 2-3 USB IBM SurePos Scan one of the following “Plug and Play” codes to program the scanner for an IBM SurePos (USB handheld scanner) or IBM SurePos (USB tabletop scanner) interface. Note: After scanning one of these codes, you must power cycle the cash register. USB IBM SurePos (USB Handheld Scanner) Interface USB IBM SurePos (USB Tabletop Scanner) Interface Each bar code above also programs the following suffixes for each symbology: Symbology Suffix Symbology Suffix EAN 8 EAN 13 UPC A UPC E 0C 16 0D 0A Code 39 Interleaved 2 of 5 Code 128 Code 39 00 00 00 00 0A 0D 18 0A 0B 0B 0B 0B USB PC or Macintosh Keyboard Scan one of the following codes to program the scanner for USB PC Keyboard or USB Macintosh Keyboard. Scanning these codes also adds a CR and LF. USB Keyboard (PC) USB Keyboard (Mac) USB Japanese Keyboard (PC) 2-4 USB HID Scan the following code to program the scanner for USB HID bar code scanners. USB HID Bar Code Scanner USB Serial Scan the following code to program the scanner to emulate a regular RS232-based COM Port. If you are using a Microsoft® Windows® PC, you will need to download a driver from the Honeywell website (www.honeywellaidc.com). The driver will use the next available COM Port number. Apple® Macintosh computers recognize the scanner as a USB CDC class device and automatically uses a class driver. USB Serial Note: No extra configuration (e.g., baud rate) is necessary. CTS/RTS Emulation CTS/RTS Emulation On * CTS/RTS Emulation Off 2-5 ACK/NAK Mode ACK/NAK Mode On * ACK/NAK Mode Off Verifone® Ruby Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Verifone Ruby terminal. This bar code sets the baud rate to 1200 bps and the data format to 8 data bits, no parity bit, 1 stop bit. It also also adds a line feed (LF) suffix and programs the following prefixes for each symbology: Symbology Prefix UPC-A UPC-E EAN-8 EAN-13 A A FF F Verifone Ruby Settings 2-6 Gilbarco® Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Gilbarco terminal. This bar code sets the baud rate to 2400 bps and the data format to 7 data bits, even parity, 2 stop bits. It also also adds a carriage return (CR) suffix and programs the following prefixes for each symbology: Symbology Prefix UPC-A UPC-E EAN-8 EAN-13 A E0 FF F Gilbarco Settings Honeywell Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for a Honeywell bioptic scanner auxiliary port configuration. This bar code sets the baud rate to 38400 bps and the data format to 8 data bits, no parity, 1 stop bit. Honeywell Bioptic Settings Datalogic™ Magellan© Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for a Datalogic Magellan bioptic scanner auxiliary port configuration. This bar code sets the baud rate to 9600 bps and the data format to 8 data bits, no parity, 1 stop bit. Datalogic Magellan Bioptic Settings 2-7 NCR Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for an NCR bioptic scanner auxiliary port configuration. The following prefixes are programmed for each symbology: Symbology Prefix Symbology Prefix UPC-A UPC-E EAN-8 A E0 FF Code 39 Interleaved 2 of 5 All other bar codes B1 B2 B3 EAN-13 F NCR Bioptic Settings Wincor Nixdorf Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Wincor Nixdorf terminal. This bar code sets the baud rate to 9600 bps and the data format to 8 data bits, no parity, 1 stop bit. Wincor Nixdorf Terminal Settings 2-8 Wincor Nixdorf Beetle™ Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Wincor Nixdorf Beetle terminal. The following prefixes are programmed for each symbology: Symbology Prefix Code 128 Code 93 Codabar UPC-A UPC-E EAN-8 K L N A0 C B Symbology EAN-13 GS1-128 Interleaved 2 of 5 Plessey Straight 2 of 5 IATA All other bar codes Prefix A P I O H M Wincor Nixdorf Beetle Settings 2-9 Keyboard Country Layout Scan the appropriate country code below to program the keyboard layout for your country or language. As a general rule, the following characters are supported, but need special care for countries other than the United States: @ | $ # { } [ ] = / ‘ \ < > ~ * United States United States (Dvorak) United States (Dvorak left) United States (Dvorak right) United States (International) Albania Azeri (Cyrillic) Azeri (Latin) Belarus Belgium Bosnia Brazil 2 - 10 Keyboard Country (continued) Brazil (MS) Bulgaria (Cyrillic) Bulgaria (Latin) Canada (French legacy) Canada (French) Canada (Multilingual) Croatia Czech Czech (Programmers) Czech (QWERTY) Czech (QWERTZ) Denmark Dutch (Netherlands) 2 - 11 Keyboard Country (continued) Estonia Faeroese Finland France Gaelic Germany Greek Greek (220 Latin) Greek (220) Greek (319 Latin) Greek (319) Greek (Latin) Greek (MS) 2 - 12 Keyboard Country (continued) Greek (Polytonic) Hebrew Hungarian (101 key) Hungary Iceland Irish Italian (142) Italy Japan ASCII Kazakh Kyrgyz (Cyrillic) Latin America Latvia 2 - 13 Keyboard Country (continued) Latvia (QWERTY) Lithuania Lithuania (IBM) Macedonia Malta Mongolian (Cyrillic) Norway Poland Polish (214) Polish (Programmers) Portugal Romania Russia 2 - 14 Keyboard Country (continued) Russian (MS) Russian (Typewriter) SCS Serbia (Cyrillic) Serbia (Latin) Slovakia Slovakia (QWERTY) Slovakia (QWERTZ) Slovenia Spain Spanish variation Sweden Switzerland (French) 2 - 15 Keyboard Country (continued) Switzerland (German) Tatar Turkey F Turkey Q Ukrainian United Kingdom United Stated (Dvorak right) United States (Dvorak left) United States (Dvorak) United States (International) Uzbek (Cyrillic) Refer to the Honeywell website (www.honeywell.com/aidc) for complete keyboard country support information and applicable interfaces. If you need to program a keyboard for a country other than one listed above, scan the Program Keyboard Country bar code below, then scan the numeric bar code(s) for the 2 - 16 appropriate country from the inside back cover, then the Save bar code. Program Keyboard Country Keyboard Style This programs keyboard styles, such as Caps Lock and Shift Lock. If you have used Keyboard Conversion settings, they will override any of the following Keyboard Style settings. Default = Regular. Regular is used when you normally have the Caps Lock key off. * Regular Caps Lock is used when you normally have the Caps Lock key on. Caps Lock Shift Lock is used when you normally have the Shift Lock key on (not common to U.S. keyboards). Shift Lock Automatic Caps Lock is used if you change the Caps Lock key on and off. The software tracks and reflects if you have Caps Lock on or off . This selection can only be used with systems that have an LED that notes the Caps Lock status (AT keyboards). Automatic Caps Lock 2 - 17 Autocaps via NumLock bar code should be scanned in countries (e.g., Germany, France) where the Caps Lock key cannot be used to toggle Caps Lock. The NumLock option works similarly to the regular Autocaps, but uses the NumLock key to retrieve the current state of the Caps Lock. Autocaps via NumLock Emulate External Keyboard should be scanned if you do not have an external keyboard (IBM AT or equivalent). Emulate External Keyboard Note: After scanning the Emulate External Keyboard bar code, you must power cycle your computer. Keyboard Conversion Alphabetic keyboard characters can be forced to be all upper case or all lowercase. So if you have the following bar code: “abc569GK,” you can make the output “ABC569GK” by scanning Convert All Characters to Upper Case, or to “abc569gk” by scanning Convert All Characters to Lower Case. These settings override Keyboard Style selections. Note: If your interface is a keyboard wedge, first scan the menu code for Automatic Caps Lock (page 2-17). Otherwise, your output may not be as expected. Default = Keyboard Conversion Off. * Keyboard Conversion Off Convert All Characters to Upper Case Convert All Characters to Lower Case 2 - 18 Control Character Output This selection sends a text string instead of a control character. For example, when the control character for a carriage return is expected, the output would display [CR] instead of the ASCII code of 0D. Refer to ASCII Conversion Chart (Code Page 1252) on page A-4. Only codes 00 through 1F are converted (the first column of the chart). Note: Control + ASCII Mode overrides this mode. Default = Off. Control Character Output On * Control Character Output Off Keyboard Modifiers This modifies special keyboard features, such as CTRL+ ASCII codes and Turbo Mode. Control + ASCII Mode On: The scanner sends key combinations for ASCII control characters for values 00-1F. Windows is the preferred mode. All keyboard country codes are supported. DOS mode is a legacy mode, and it does not support all keyboard country codes. New users should use the Windows mode. Refer to Keyboard Function Relationships, page 9-1 for CTRL+ ASCII Values. Windows Mode Prefix/Suffix Off: The scanner sends key combinations for ASCII control characters for values 00-1F, but it does not transmit any prefix or suffix information. 2 - 19 Default = Control + ASCII Mode Off. Windows Mode Control + ASCII Mode On * Control + ASCII Mode Off DOS Mode Control + ASCII Mode On Windows Mode Prefix/Suffix Off Turbo Mode: The scanner sends characters to a terminal faster. If the terminal drops characters, do not use Turbo Mode. Default = Off Turbo Mode On * Turbo Mode Off Numeric Keypad Mode: Sends numeric characters as if entered from a numeric keypad. Default = Off Numeric Keypad Mode On * Numeric Keypad Mode Off 2 - 20 Automatic Direct Connect Mode: This selection can be used if you have an IBM AT style terminal and the system is dropping characters. Default = Off Automatic Direct Connect Mode On * Automatic Direct Connect Mode Off 2 - 21 RS232 Baud Rate Baud Rate sends the data from the scanner to the terminal at the specified rate. The host terminal must be set for the same baud rate as the scanner. Default = 9600. 300 600 1200 2400 4800 * 9600 19200 38400 57,600 115,200 2 - 22 RS232 Word Length: Data Bits, Stop Bits, and Parity Data Bits sets the word length at 7 or 8 bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For applications that require use of the full ASCII set, select 8 data bits per character. Default = 8. Stop Bits sets the stop bits at 1 or 2. Default = 1. Parity provides a means of checking character bit patterns for validity. Default = None. 7 Data, 1 Stop, Parity Even 7 Data, 1 Stop, Parity None 7 Data, 1 Stop, Parity Odd 7 Data, 2 Stop, Parity Even 7 Data, 2 Stop Parity None 7 Data, 2 Stop, Parity Odd 8 Data, 1 Stop, Parity Even * 8 Data, 1 Stop, Parity None 8 Data, 1 Stop, Parity Odd 2 - 23 RS232 Receiver Time-Out The unit stays awake to receive data until the RS232 Receiver Time-Out expires. A manual or serial trigger resets the time-out. When an RS232 receiver is sleeping, a character may be sent to wake up the receiver and reset the time-out. A transaction on the CTS line will also wake up the receiver. The receiver takes 300 milliseconds to completely come up. Change the RS232 receiver time-out by scanning the bar code below, then scanning digits from the inside back cover of this manual, then scanning Save. The range is 0 to 300 seconds. Default = 0 seconds (no time-out - always on). RS232 Receiver Time-Out RS232 Handshaking RS232 Handshaking allows control of data transmission from the scanner using software commands from the host device. When RTS/CTS is turned Off, no data flow control is used. Flow Control, No Timeout: The scanner asserts RTS when it has data to send, and will wait indefinitely for CTS to be asserted by the host. Two-Direction Flow Control: The scanner asserts RTS when it is OK for the host to transmit. The host asserts CTS when it is OK for the device to transmit. Flow Control with Timeout: The scanner asserts RTS when it has data to send and waits for a delay (see RS232 Timeout on page 2-25) for CTS to be asserted by the host. If the delay time expires and CTS is not asserted, the device transmit buffer is cleared and scanning may resume. Default = RTS/CTS Off. Flow Control, No Timeout Two-Direction Flow Control Flow Control with Timeout * RTS/CTS Off 2 - 24 RS232 Timeout When using Flow Control with Timeout, you must program the length of the delay you want to wait for CTS from the host. Set the length (in milliseconds) for a timeout by scanning the bar code below, then setting the timeout (from 1-5100 milliseconds) by scanning digits from the inside back cover, then scanning Save. RS232 Timeout XON/XOFF Standard ASCII control characters can be used to tell the scanner to start sending data (XON/XOFF On) or to stop sending data (XON/XOFF Off). When the host sends the XOFF character (DC3, hex 13) to the scanner, data transmission stops. To resume transmission, the host sends the XON character (DC1, hex 11). Data transmission continues where it left off when XOFF was sent. Default = XON/XOFF Off. XON/XOFF On * XON/XOFF Off ACK/NAK After transmitting data, the scanner waits for an ACK character (hex 06) or a NAK character (hex 15) response from the host. If ACK is received, the communications cycle is completed and the scanner looks for more bar codes. If NAK is received, the last set of bar code data is retransmitted and 2 - 25 the scanner waits for ACK/NAK again. Turn on the ACK/NAK protocol by scanning the ACK/NAK On bar code below. To turn off the protocol, scan ACK/NAK Off. Default = ACK/NAK Off. ACK/NAK On * ACK/NAK Off Scanner to Bioptic Communication The following settings are used to set up communication between Honeywell scanners and bioptic scanners. Note: The scanner’s baud rate must be set to 38400 and the RS232 timeout must be set to 3000 in order to communicate with a bioptic scanner. See RS232 Baud Rate on page 2-22, and RS232 Timeout on page 2-25 for further information. Scanner-Bioptic Packet Mode Packet Mode On must be scanned to set the scanner’s format so it is compatible with a bioptic scanner. Default = Packet Mode Off. * Packet Mode Off Packet Mode On 2 - 26 Scanner-Bioptic ACK/NAK Mode Bioptic ACK/Nak On must be scanned so the scanner will wait for an ACK or NAK from a bioptic scanner after each packet is sent. The ScannerBioptic ACK/NAK Timeout (below) controls how long the scanner will wait for a response. Default = Bioptic ACK/NAK Off. * Bioptic ACK/NAK Off Bioptic ACK/NAK On Scanner-Bioptic ACK/NAK Timeout This allows you to set the length (in milliseconds) for a timeout for a bioptic scanner’s ACK/NAK response. Scan the bar code below, then set the timeout (from 1-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save. Default = 5100. ACK/NAK Timeout 2 - 27 2 - 28 3 Cordless System Operation Note: This chapter applies only to cordless scanning systems. It does not apply to corded scanners. How the Cordless Charge Base/Access Point Works A cordless charge base or an Access Point provide the link between the cordless scanner and the host system. The base/Access Point contains an interface assembly and an RF communication module. The RF communication module performs the data exchange between the cordless scanner and the interface assembly. The control assembly coordinates the central interface activities including: transmitting/receiving commands and data to/from the host system, performing software activities (parameter menuing, visual indicator support, power-on diagnostics), and data translation required for the host system. The cordless charge base is also a scanner’s battery charger. Refer to Charging Information, page 3-5, for additional information. Linking the Scanner to a Charge Base Turn off power before connecting a base, then power up the computer once the base is fully connected. When the base is connected and powered up, put the scanner in the base to establish a link. The green LED on the base flashes to indicate the scanner’s battery is charging. If the scanner and base have previously been linked, you do not receive any feedback. If this is the first time that the scanner and base are linked, both devices emit a short chirp when their radios link. At this point, that one scanner is linked to one base. Scanner CCB01-010BT Charge Base Page Button and Base LEDs To determine if your cordless system is set up correctly, scan one of the sample bar codes in the back of this manual. If the scanner provides a single good read beep and the green LED lights, the scanner has successfully linked to the base. If you receive an error tone and the red LED lights, the scanner has not linked to the base. Refer to page 13-6 for troubleshooting information. 3-1 Linking the Scanner to an Access Point Turn on the computer (laptop/desktop). Plug the interface cable into the Access Point first and then into the appropriate port on the computer. The Page button lights up when the connection to the host is made. Page Button Scan the linking bar code on the top of the Access Point to establish a connection between the Access Point and the scanner. The scanner emits a short beep and flashes the green LED to confirm a connection with the Access Point. The Access Point’s Page button remains blue. Communication Between the Cordless System and the Host The cordless scanner provides immediate feedback in the form of a “good read” indication (a green LED on the scanner and an audible beep) after a bar code is scanned correctly and the base or Access Point has acknowledged receiving the data. This is possible since the cordless system provides two-way communication between the scanner and the base or Access Point. When data is scanned, the data is sent to the host system via the base or Access Point. The cordless scanner recognizes data acknowledgement (ACK) from the base or Access Point. If it cannot be determined that the data has 3-2 been properly sent to the base or Access Point, the scanner issues an error indication. You must then check to see if the scanned data was received by the host system. 1) Good Read 3) Base or Access Point sends data to host 2) ACK from base or Access Point RF (Radio Frequency) Module Operation The cordless system uses a two-way Bluetooth® radio to transmit and receive data between the scanner and the base or Access Point. Designed for point-topoint and multipoint-to-single point applications, the radio operates using a license free ISM band, which sends relatively small data packets at a fast data rate over a radio signal with randomly changing frequencies, makes the cordless system highly responsive to a wide variety of data collection applications and resistant to noisy RF environments. Bluetooth Class 2 power level provides a communication range of 33 feet (10m) between the scanner and base or Access Point, depending on the environment. See Flexible Power Management, page 3-15, for information about controlling this range. System Conditions The components of the cordless system interact in specific ways as you associate a scanner to a base or Access Point, as you move a scanner out of range, bring a scanner back in range, or swap scanners between two cordless systems. The following information explains the cordless system operating conditions. Linking Process Once a scanner is placed into a cordless charge base, the scanner’s battery charge status is checked, and software automatically detects the scanner and links it to the base depending on the selected link mode. Refer to Linking the Scanner to an Access Point, page 3-2, for information about linking to an Access Point. 3-3 Scanner Is Out of Range The cordless scanner is in communication with its base or Access Point, even when it is not transmitting bar code data. Whenever the scanner can’t communicate with the base or Access Point for a few seconds, it is out of range. If the scanner is out of range and you scan a bar code, the scanner issues an error tone indicating no communication with the base or Access Point. A cordless charge base can also sound an alarm. Refer to Out-ofRange Alarm, page 3-13. Scanner Is Moved Back Into Range The scanner relinks if the scanner or the base or Access Point have been reset, or the scanner comes back into range. If the scanner relinks, you will hear a single chirp when the relinking process (uploading of the parameter table) is complete. Refer to Out-of-Range Alarm on page 3-13 for further information. Out of Range and Back into Range with Batch Mode On The scanner may store a number of symbols (approximately 500 U.P.C. symbols; others may vary) when it is out of range and then send them to the base or Access Point when back in range (see Batch Mode on page 316). You will not hear a communication error tone in this mode, but you will hear a short buzz when you pull the trigger if the radio communication is not working. Once the radio connection is made, the scanner produces a series of beeps while the data is being transferred to the base or Access Point. Page Button When you press the Page button on the base or Access Point, the scanners associated with that base or Access Point will begin beeping (3 short and 1 long beep). If you pull the trigger on a scanner that is beeping in response, or press the Page button on the base or Access Point a second time, all associated scanners will stop beeping. See Paging on page 3-9 for further information about Page Button settings. About the Battery ! There is a danger of explosion if the batteries are incorrectly replaced. Replace the batteries with only the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the recycle program for batteries as directed by the governing agency for the country where the batteries are to be discarded. Power is supplied to the cordless scanner by a rechargeable battery that is integrated in the scanner handle. Batteries are shipped approximately 30% to 60% charged. The battery should be charged for a minimum of 4 hours before initial use to ensure optimal performance. 3-4 Charging Information The battery is designed to charge while the scanner is positioned in the cordless base unit. Refer to Base/Access Point LED Sequences and Meaning, page 3-7, for an interpretation of the Charge Status indicators. Refer to Charge Only Mode (page 3-11) if you need to charge a scanner without linking it to the base. Place the scanner in the base that is connected to an appropriate power supply. Use only a Listed Limited Power Source (LPS) or Class 2 type power supply with output rated 5 to 5.2Vdc, 1A. Note: If you are powering the base through the interface cable (for example, a USB cable) and not using an external power supply plugged into the aux port, the current available for charging is reduced and charge times are increased. Battery Recommendations • The battery is a lithium ion cell and can be used without a full charge, and can also be charged without fully discharging, without impacting the battery life. There is no need to perform any charge/discharge conditioning on this type of battery. • Keep the base connected to power when the host is not in use. • Replace a defective battery immediately since it could damage the scanner. • Although your battery can be recharged many times, it will eventually be depleted. Replace it after the battery is unable to hold an adequate charge. • If you are not sure if the battery or charger is working properly, send it to Honeywell International Inc. or an authorized service center for inspection. Refer to Customer Support on page 14-1 for additional information. ! Caution: Use only Honeywell Li-ion battery packs, part number 100000495, rated 3.7 Vdc, 7.4Whr, in this device. Use of any non-Honeywell battery may result in damage not covered by the warranty. Safety Precautions for Lithium Batteries • • • • • • • Do not place batteries in fire or heat the batteries. Do not store batteries near fire or other high temperature locations. Do not store or carry batteries together with metal objects. Do not expose batteries to water or allow the batteries to get wet. Do not connect (short) the positive and negative terminals, of the batteries, to each other with any metal object. Do not pierce, strike or step on batteries or subject batteries to strong impacts or shocks. Do not disassemble or modify batteries. 3-5 ! Caution: Danger of explosion if batteries are incorrectly replaced. Dispose of used batteries according to the recycle program for batteries as directed by the governing agency for the country where the batteries are to be discarded. Proper Disposal of the Battery When the battery has reached the end of its useful life, the battery should be disposed of by a qualified recycler or hazardous materials handler. Do not incinerate the battery or dispose of the battery with general waste materials. You may send the scanner’s battery to us. (postage paid). The shipper is responsible for complying with all federal, state, and local laws and regulations related to the packing, labeling, manifesting, and shipping of spent batteries. Contact the Product Service Department (page 141) for recycling or disposal information. Since you may find that your cost of returning the batteries significant, it may be more cost effective to locate a local recycle/disposal company. Beeper and LED Sequences and Meaning The scanner contains LEDs on the rear of the unit that indicate linking status, decoding state, and battery condition. The base has LEDs on the top of the unit that indicate its power up, communication, and battery charge condition. The red LED = error; green LED = success of any type. The unit’s audible indicators have meaning as well: 1 razz or error tone = error; 2 beeps = menu change; 1 beep = all other successes. The table below lists the indication and cause of the LED illumination and beeps for the scanner. 3-6 Scanner LED Sequences and Meaning LED Indication Beeper Indication Cause Normal Operation Red Flash Green Flash None 1 beep Battery low Successful communication or linking Failed communication Red, blinking Menu Operation Green Flash Red, blinking Razz or error tone 2 beeps Razz or error tone Successful menu change Unsuccessful menu change Base/Access Point LED Sequences and Meaning The base contains a red LED and the Access Point has a blue LED that indicate the status of the unit and verifies its communication with the host system. The base also has a green LED that indicates scanner battery charge condition. Red or Blue LED - Host Communication Communication Condition Red or Blue LED USB suspend Off Power on, system idle On continuously Receiving data Short blinks in multiple pulses. Occurs while transferring data to/from the RF module or the Host port. Green LED - Scanner Battery (base only, does not apply to Access Point) Charge Condition Green LED Battery not detected or charge suspended Off Pre-charge and charging Slow flash, 1 second on, 1 second off Charge complete On continuously Charge Error Fast flash, 300 mSec on, 300 mSec off 3-7 Base Power Communication Indicator To display the power indicator on a base or an Access Point, scan the Base Power Communication Indicator On bar code. To turn off the power indicator, scan the Off bar code. Default = On. * Base Power Communication Indicator On Base Power Communication Indicator Off Reset Scanner Scanning this bar code reboots the scanner and causes it to relink with the base or Access Point. Reset Scanner Scanning While in Base Cradle Note: This feature does not apply to the Access Point. If you want to be able to scan bar codes while the scanner is in the base cradle, scan the Scanning in Cradle On bar code below. If you want to only allow scanning when the scanner is out of the base cradle, scan Scanning in Cradle Off. If you want the scanner to shut down when in the base cradle, scan Shut Down Scanner in Cradle. Default = Scanning in Cradle On. Scanning in Cradle Off * Scanning in Cradle On Shut Down Scanner in Cradle 3-8 Paging Paging Mode By default, the paging button on the base or Access Point pages the scanners associated with that base or Access Point. If you want the paging button on your base or Access Point to be disabled, scan the Paging Mode Off bar code, below. When Paging Mode is off, the base or Access Point will no longer page scanners when the button is pressed. The red LED on the base or blue LED on the Access Point will remain lit to indicate that Paging Mode is off. (This light will go out when the button is pressed, then back on when it’s released.) Default = Paging Mode On. * Paging Mode On Paging Mode Off Paging Pitch When you press the Page button on the base or Access Point, the scanners associated with that base or Access Point will begin beeping (see Page Button on page 3-4). You can set the pitch of the paging beep for each scanner by scanning one of the following bar codes. Default = Low. * Low (1000 Hz) Medium (3250 Hz) High (4200 Hz) Error Indicators Beeper Pitch - Base Error Note: This feature does not apply to the Access Point. 3-9 The base can be configured to beep at a particular pitch when an error occurs, such as transmission problems to a host system. The beeper pitch codes modify the pitch (frequency) of the error tone the base emits when there is an error. Default = Low. * Razz (250 Hz) Medium (3250 Hz) High (4200 Hz) Number of Beeps - Base Error Note: This feature does not apply to the Access Point. The number of beeps and LED flashes emitted by the base for an error condition can be programmed from 1 - 9. For example, if you program this option to have five error beeps, there will be five error beeps and five LED flashes in response to an error. To change the number of error beeps, scan the bar code below and then scan a digit (1-9) bar code and the Save bar code on the Programming Chart inside the back cover of this manual. Default = 1. Number of Base Error Beeps/LED Flashes Scanner Report Scan the bar code below to generate a report for the connected scanners. The report indicates the port, work group, scanner name, and address. To assign a name to your scanner, refer to Menu Command Syntax, page 11-1. Scanner Report 3 - 10 Scanner Address Scan the bar code below to determine the address of the scanner you are using. Scanner Address Base or Access Point Address Scan the bar code below to determine the address of the base or Access Point you are using. Base Address Scanner Modes The Xenon is capable of working in single scanner mode, multiple scanner mode, or with Bluetooth devices other than the CCB01-010BT charge base or Access Point. Charge Only Mode There may be times when you want to charge your scanner, but not link to the base. For example, if a scanner is linked to an Access Point or other Bluetooth device and you need to charge the scanner, but want to retain your existing link. In order to program the base for Charge Only Mode, you must link a scanner to it. Once the scanner is linked to the base, scan the Charge Only Mode bar code. Any subsequent scanners placed in that base will charge without linking to it. The scanner used to program the base remains linked to the base. To unlink this scanner, scan Unlink Scanner on page 3-13. Charge Only Mode Note: When in Charge Only Mode, the scanner periodically wakes up and beeps. See "Power Up Beeper" on page 4-1 to change this setting. 3 - 11 If you want to charge a scanner and link to the base, use Charge and Link Mode. If the base is programmed for Charge Only Mode, you must link a scanner to it first in order to program it for Charge and Link Mode. Scan the linking bar code on the base to link the scanner, then scan Charge and Link Mode. Default = Charge and Link Mode. * Charge and Link Mode Linked Modes Locked Link Mode and Open Link Mode are the link modes that accommodate different applications. Scan the appropriate bar codes included in the Open Link and Locked Link Mode explanations that follow to switch from one mode to another. Default = Open Link Mode. Locked Link Mode - Single Scanner If you link a scanner to a base or an Access Point using the Locked Link Mode, other scanners are blocked from being linked if they are inadvertently placed into the base, or if the Access Point linking bar code is scanned. If you do place a different scanner into a base, it will charge the scanner, but the scanner will not be linked. Locked Link Mode (Single Scanner) To use a different scanner, you need to unlink the original scanner by scanning the Unlink Scanner bar code. (See Scanner Modes, page 3-11.) Open Link Mode - Single Scanner When newly shipped or defaulted to factory settings, a scanner is not linked to a base or an Access Point. A link is established when the scanner is placed into a base, or an Access Point linking bar code is scanned. When in Open Link Mode, a new link is established when a new scanner is placed in the base, or you scan an Access Point linking 3 - 12 bar code. Each time a scanner is placed into a base or scans an Access Point linking bar code, the scanner becomes the linked to the base or Access point and the old scanner is unlinked. * Open Link Mode (Single Scanner) Unlinking the Scanner If a base or an Access Point has a scanner linked to it, that scanner must be unlinked before a new scanner can be linked. Once the previous scanner is unlinked, it will no longer communicate with the base or Access Point. To unlink the scanner from a base or an Access Point, scan the Unlink Scanner bar code below. Unlink Scanner Override Locked Scanner If you need to replace a broken or lost scanner that is linked to a base or an Access Point, scan the Override Locked Scanner bar code below with a new scanner and place that scanner in the base, or scan the Access Point linking bar code. The locked link will be overridden; the broken or lost scanner’s link with the base or Access Point will be removed, and the new scanner will be linked. Override Locked Scanner (Single Scanner) Out-of-Range Alarm If your scanner is out range of the base, an alarm sounds from both your base and scanner. If your scanner is out range of an Access Point, an alarm sounds from just the scanner. The alarm stops when the scanner is moved closer to the base or Access Point, when the base or Access Point connects to another scanner, or when the alarm duration expires. To activate the alarm options for the scanner or the base and to set the alarm duration, scan the appropriate bar 3 - 13 code below and then set the time-out duration (from 0-3000 seconds) by scanning digits on the Programming Chart inside the back cover, then scanning Save. Default = 0 sec (no alarm). Note: Base Alarm Duration The Access Point does not have a base alarm. Scanner Alarm Duration Note: If you are out of range when you scan a bar code, you will receive an error tone even if you do not have the alarm set. You receive the error tone since the data could not be communicated to the base or Access Point or the host. Alarm Sound Type You may change the alarm type for the scanner or base by scanning the appropriate bar code below and then scanning a digit (0-7) bar code and the Save bar code on the Programming Chart inside the back cover of this manual. Default = 0. The sounds are as follows: Setting Sound 0 3 long beeps, medium pitch 1 3 long beeps, high pitch 2 4 short beeps, medium pitch 3 4 short beeps, high pitch 4 single chirps, medium pitch 5 2 chirps, then 1 chirp, medium pitch 6 single chirps, high pitch 7 2 chirps, then 1 chirp, high pitch Base Alarm Type Note: The Access Point does not have a base alarm. Scanner Alarm Type 3 - 14 Flexible Power Management If you are experiencing network performance issues, and suspect the scanner is interfering with other devices, you can turn down the power output of the scanner. This reduces the range between the scanner and a base or an Access Point as shown in the following illustration: 802.11 LAN 1902 Scanner Red r uced Powe Full Power Scan one of the bar codes below to set the scanner’s power output to Full Power (100%) [2.5mW, 4dBm], Medium Power (35%) [.875mW, 0dBm], Medium Low Power (5%) [.125mW, -9dBm], or Low Power (1%, .025mW, -16dBm). Default = Full Power. For the new power setting to take effect, the scanner and the base or Access Point must be reset. See Reset Scanner and Base/Access Point (page 316). * Full Power Medium Power Medium Low Power Low Power 3 - 15 Reset Scanner and Base/Access Point Once the power level is set, you must scan the Reset Base bar code and wait for the scanner to unlink and relink to a base or an Access Point. Once that is done, scan the Reset Scanner bar code and wait for the base or Access Point to unlink and relink to the scanner. Reset Base : * : RESE T _ . ³ Reset Scanner Batch Mode Batch mode is used to store bar code data when a scanner is out of range of its base or Access Point, or when performing inventory. The data is transmitted to the base or Access Point once the scanner is back in range or when the records are manually transmitted. Note: Batch mode has limitations when using multiple scanners to one base or Access Point. If a cordless system is being used in "multiple link mode," where up to 7 scanners are to be connected to one base or Access Point, some accumulated or batched scans could be lost if scanners are constantly being moved in and out of range. Automatic Batch Mode stores bar code data when the scanner is out of range of the base or Access Point. The data is automatically transmitted to the base or Access Point once the scanner is back in range. When the scanner’s buffer space is full, any bar codes scanned generate an error tone. In order to scan bar codes again, the scanner must be moved back into range of the base or Access Point so data can be transmitted. Inventory Batch Mode stores bar code data, whether or not you are in range of the base or Access Point. To transmit the stored data to the base or Access Point, either place the scanner in the base, or scan Transmit Inventory Records (page 3-21). When the scanner’s buffer space is full, any bar codes scanned generate an error tone. In order to scan bar codes again, the data must be transmitted to the base or Access Point. 3 - 16 Default = Batch Mode Off. * Batch Mode Off Automatic Batch Mode Inventory Batch Mode Batch Mode Beep When using Batch Mode, scan Batch Mode Beep On to program the scanner to click when each bar code is read to storage. Default = Batch Mode Beep On. Batch Mode Beep Off * Batch Mode Beep On Batch Mode Storage When a scanner is storing data during a Batch Mode process, you can select whether the data is stored in Flash memory or in RAM. Flash Storage: The scanner writes any untransmitted data to flash memory prior to powering down. The data will still be there when the scanner powers back up. However, the scanner will power down, even with untransmitted data, if it reaches a power down timeout or if the battery power is very low. 3 - 17 RAM Storage: The scanner will not power down while it contains data that has not been transmitted to the base or Access Point, even if it reaches a power down timeout. However, if the scanner runs out of battery power, it will power down and the data will be lost. Default = Flash Storage. * Flash Storage RAM Storage Batch Mode Quantity When in Batch Mode, you may wish to transmit the number of multiple bar codes scanned, rather than a single bar code multiple times. For example, if you scan three bar codes called XYZ with Batch Mode Quantity Off, when you transmit your data it will appear as XYZ three times. Using Batch Mode Quantity On and the Quantity Codes (page 3-19), you could output your data as “XYZ, 00003” instead. Default = Batch Mode Quantity Off. * Batch Mode Quantity Off Batch Mode Quantity On Entering Quantities Quantity Codes (page 3-19) allow you to enter a quantity for the last item scanned, up to 9999 (default = 1). Quantity digits are shifted from right to left, so if a 5th digit is scanned, the 1st digit scanned is discarded and the 2nd, 3rd and 4th digits are moved to the left to accommodate the new digit. For example, if the Quantity 5 bar code is scanned after the quantity has been set to 1234, then the 1 is dropped, the quantity will be 2345. Example: Add a quantity of 5 for the last item scanned. 1. Scan the item's bar code. 2. Scan the quantity 5 bar code. Example: Add a quantity of 1,500 for the last item scanned. 1. Scan the item's bar code. 3 - 18 2. 3. 4. 5. Scan the quantity 1 bar code. Scan the quantity 5 bar code. Scan the quantity 0 bar code. Scan the quantity 0 bar code. Example: Change a quantity of 103 to 10. To correct an incorrect quantity, scan the quantity 0 bar code to replace the incorrect digits, then scan the correct quantity bar codes. 1. 2. 3. 4. Scan the quantity 0 bar code to change the quantity to 1030. Scan the quantity 0 bar code to change the quantity to 0300. Scan the quantity 1 bar code to change the quantity to 3001. Scan the quantity 0 bar code to change the quantity to 0010. Default = 1. Quantity Codes 0 1 2 3 4 5 6 7 3 - 19 Quantity Codes (continued) 8 9 Batch Mode Output Order When batch data is transmitted, select whether you want that data sent as FIFO (first-in first-out), or LIFO (last-in last-out). Batch Mode FIFO Batch Mode LIFO Delete Last Code If you want to delete the last bar code scanned when in Batch Mode, scan Delete Last Code. Delete Last Code Clear All Codes If you want to clear the scanner’s buffer of all data accumulated in Batch Mode, scan Clear All Codes. Clear All Codes 3 - 20 Transmit Records to Host If you are operating in Inventory Batch Mode (see Inventory Batch Mode on page 3-17), you must scan the following bar code to transmit all the stored data to the host system. Transmit Inventory Records Batch Mode Transmit Delay Sometimes when accumulated scans are sent to the host system, the transmission of those scans is too fast for the application to process. To program a transmit delay between accumulated scans, scan one of the following delays. Default = Off. Note: In most cases, a short (250 ms (milliseconds)) delay is ideal, however, longer delays may be programmed. Contact Technical Support (page 14-3) for additional information. * Batch Mode Transmit Delay Off (No Delay) Batch Mode Transmit Delay Short (250 ms) Batch Mode Transmit Delay Medium (500 ms) Batch Mode Transmit Delay Long (1000 ms) Multiple Scanner Operation Note: Multiple Scanner Operation Mode allows you to link up to 7 scanners to one base or Access Point. You cannot join an 8th scanner until you unlink one of the 7 scanners or take a scanner out of range. 3 - 21 To put the scanner in multiple scanner mode, scan the bar code below. Once you scan this bar code, the scanner is unlinked from the base or Access Point and must either be placed into the base, or you must scan the Access Point linking bar code in order to relink. Multiple Scanner Operation Scanner Name You may assign a name to each scanner you are using for identification purposes. For example, you may want to have a unique identifier for a scanner that is receiving imaging commands sent from the base or Access Point. The default name for a Xenon is “Xenon.” If you have more than one scanner linked to a base, and they all have the same default name, the first scanner linked to the base receives commands. When renaming a series of scanners with identical default names, unlink all except one of the scanners from the base. Perform the rename operation using either the bar codes on page 3-23, or by sending the serial command :Xenon:BT_NAMname. where name is the new name for the scanner. If you wish to change the names of additional scanners, link them one at a time and repeat the :Xenon:BT_NAMname. command for each scanner. 3 - 22 To rename scanners with sequential, numeric names, scan the bar codes below. Scan the Reset code after each name change and wait for the scanner to relink to the base or Access Point before scanning a bar code to rename the next scanner. 0001 0002 0003 0004 0005 0006 0007 Reset You may also scan the Scanner Name bar code below and scan a number for the scanner name. For example, if you wanted to name the linked scanner “312,” you would scan the bar code below, scan the 3, 1, and 2 bar codes on the Programming Chart inside the back cover of this manual, then scan Save. Scan the Reset bar code and wait for the scanner to relink to the base. Scanner Name 3 - 23 Application Work Groups Your cordless system can have up to 7 scanners linked to one base or Access Point. You can also have up to 7 work groups. If you want to have all of the scanners’ settings programmed alike, you don’t need to use more than 1 work group. If you want each scanner to have unique settings (e.g., beeper volume, prefix/suffix, data formatter), then you may program each scanner to its own unique work group and may program each scanner independently. For example, you might want to have multiple work groups in a retail/warehouse application where you need to have different data appended to bar codes used in the warehouse area versus the retail area. You could assign all the scanners in the retail area to one work group and those in the warehouse to another. Consequently, any desired changes to either the retail or warehouse area would apply to all scanners in that particular work group. Honeywell’s online configuration tool, EZConfig (page 10-2), makes it easy for you to program your system for use with multiple scanners and multiple work groups. The scanner keeps a copy of the menu settings it is using. Whenever the scanner is connected or reconnected to a base or an Access Point, the scanner is updated with the latest settings from the base or Access Point for its work group. The scanner also receives menu setting changes processed by the base or Access Point. If a scanner is removed from a base or an Access Point and placed into another base or linked to another Access Point, it will be updated with the new base/Access Point settings for whatever work group to which that the scanner was previously assigned. For example, if the scanner was in work group 1 linked to the first base, it will be placed in work group 1 in the second base with the associated settings. 3 - 24 Application Work Group Selection This programming selection allows you to assign a scanner to a work group by scanning the bar code below. You may then program the settings (e.g., beeper volume, prefix/suffix, data formatter) that your application requires. Default = Group 0. * Group 0 Group 1 Group 2 Group 3 Group 4 Group 5 Group 6 Resetting the Factory Defaults: All Application Work Groups The following bar code defaults all of the work groups to the factory default settings. PAPDFT& Factory Default Settings: All Work Groups 3 - 25 To see what the factory default settings are, refer to the table of Menu Commands, beginning on page 11-5. The standard product default settings for each of the commands are indicated by an asterisk (*). Note: Scanning this bar code also causes both the scanner and the base or Access Point to perform a reset and become unlinked. The scanner must be placed in the base, or the Access Point linking bar code must be scanned to re-establish the link. Refer to Scanner Modes, page 3-11 for additional information. If your scanner is in multiple scanner mode, you will hear up to 30 seconds of beeping while all scanners are relinked to the base or Access Point and the settings are changed. Resetting the Custom Defaults: All Application Work Groups If you want the custom default settings restored to all of the work groups, scan the Custom Product Default Settings bar code below. (If there are no custom defaults, it will reset the work groups to the factory defaults.) See Setting Custom Defaults on page 1-9 for further information about custom defaults. Custom Default Settings: All Work Groups Note: Scanning this bar code also causes both the scanner and the base or Access Point to perform a reset and become unlinked. The scanner must be placed in its base, or the Access Point linking bar code must be scanned to re-establish the link. Refer to Scanner Modes, page 3-11 for additional information. If your scanner is in multiple scanner mode, you will hear up to 30 seconds of beeping while all scanners are relinked to the base or Access Point and the settings are changed. Using the Scanner with Bluetooth Devices The scanner can be used either with the CCB01-010BT charge base, an Access Point, or with other Bluetooth devices. Those devices include personal computers, laptops, PDAs, and Honeywell mobility systems devices. PCs/Laptops Scanning the Non-Base BT Connection bar code below allows the scanner to be used with other Bluetooth devices (e.g., PC/laptop). After you scan the bar code below, follow the instructions supplied with your Bluetooth device to locate the scanner and connect to it. If you go out of range 3 - 26 with your scanner, the scanner will not reconnect to the Bluetooth device when it is back in range. If you want to relink to the charge base or Access Point, refer to Override Locked Scanner, page 3-13. Note: The multiple work groups option is not available when you are using the scanner with Bluetooth devices other than the charge base or Access Point. Non-Base BT Connection PDAs/Mobility Systems Devices You may also use the scanner with a PDA or a Honeywell Mobility Systems device. Scan the bar code below and follow the instructions supplied with your Bluetooth device to locate the scanner, and connect with it. BT Connection - PDA/Mobility Systems Device Changing the Scanner’s Bluetooth PIN Code Some devices require a PIN code as part of the Bluetooth security features. Your scanner’s default PIN is 1234, which you may need to enter the first time you connect to your PDA or PC. The PIN code must be between 1 and 16 characters. To change the PIN, scan the bar code below and then scan the appropriate numeric bar codes from the Programming Chart inside the back cover of this manual. Scan Save to save your selection. Bluetooth PIN Minimizing Bluetooth/ISM Band Network Activity The settings described below can help you customize the relinking behavior of the cordless area-imaging system to obtain the best compromise between convenience and low interference. Note: ISM band refers to the 2.4 to 2.48 GHz frequency band used by wireless networks, cordless phones, and Bluetooth. 3 - 27 Auto Reconnect Mode Auto Reconnect controls whether or not the scanner automatically begins the relink process when a loss of connection is detected. When the Auto Reconnect On bar code is scanned, the scanner begins the relink process immediately, without user intervention. Default = Auto Reconnect On. * Auto Reconnect On Auto Reconnect Off Note: If you are connecting to a Bluetooth Interface Module, set Auto Reconnect to Off. The table below shows the results of the Auto Reconnect On and Off settings: Event Auto Reconnect On Auto Reconnect Off Scanner out of range Relink occurs automatically. If maximum number of link attempts is unsuccessful, then the scanner must be relinked by either pulling the trigger, placing the scanner in the base, or scanning the Access Point linking bar code. (See Maximum Link Attempts on page 3-29.) The scanner is relinked by pulling the trigger, or scanning the Access Point linking bar code. Base or Access point reset (firmware upgrade or power cycle) Scanner behaves as if out of range. No attempt to relink made while base or Access Point is powered off. Trigger must be pulled to initiate relinking. 3 - 28 Event Auto Reconnect On Auto Reconnect Off Scanner power down due to Power Time-Out Timer setting (see page 47) Trigger must be pulled, Access Point linking bar code must be scanned, or the scanner must be placed in the base unit to relink. (Note: scanner relinks on power up, but powers on due to one of the above actions.) Scanner reset due to firmware upgrade Relink occurs automatically. Scanner reset due to battery change Relink occurs automatically. Scanner placed in different base unit Relink to new base occurs automatically. Maximum Link Attempts The Maximum Link Attempts setting controls the number of times the scanner tries to form a connection with a base or an Access Point. During the connection setup process, the scanner transmits in order to search for and connect to a base or an Access Point. In order to prevent continuous transmissions that could interfere with other users of the ISM band, the number of attempts to connect is limited by this setting. After the maximum number of attempts is reached, the scanner will not attempt to reconnect to a base or an Access Point. Pressing the trigger, scanning an Access Point linking bar code, or placing the scanner in the cradle resets the attempt count and the scanner will again try to link. Scan the Maximum Link Attempts bar code, then scan the number of attempts for the setting (from 0-100) from the inside back cover. Scan Save to save the setting. Default = 0. Maximum Link Attempts Note: When Auto Reconnect Mode is On, setting Maximum Link Attempts to zero will cause the scanner to try to link until the Power Time-Out Timer setting (see page 4-7) expires. When Auto Reconnect Mode is Off, setting Maximum Link Attempts to zero will cause the scanner to only attempt linking one time after a trigger pull. 3 - 29 Relink Time-Out Relink Time-Out controls the idle time between relink attempts. An attempt to link a scanner to a base or an Access Point typically lasts up to 5 seconds. This is the time when the scanner is actually attempting a contact . Relink Time-Out controls the amount of time, in seconds, that elapses between the end of one connection attempt and the start of the next. Note: The length of time for an attempt depends on the number of scanners connected to a base unit or Access Point. An extra 7 seconds may be required when a connection is successful. Scan the Relink Time-Out bar code, then scan the number of seconds for the setting (from 1-100) from the inside back cover. Scan Save to save the setting. Default = 3 seconds. Relink Time-Out Bluetooth/ISM Network Activity Examples Default values When the scanner goes out of range, the scanner repeatedly attempts to connect to the base unit or Access Point. Each attempt consists of approximately 5 seconds of active time followed by 3 seconds of idle time. After one hour, the scanner powers off and batch mode data is lost. Maximum Link Attempts set to 15 Other values at default setting When the scanner goes out of range, 15 attempts are made to link to the base unit or Access Point. Each attempt consists of approximately 5 seconds of active time followed by 3 seconds of idle time. After 15 cycles (8*15 =120), or about 2 minutes, the scanner stops trying to connect to the base or Access Point, but retains any bar codes that may have been saved in batch mode. After one hour, the scanner powers off and batch mode data is lost. Auto Reconnect Mode set to 0 Maximum Link Attempts set to 15 Other values at default setting When the scanner goes out of range, no action is taken to relink. When the trigger is pulled, 15 attempts are made to link to the base or Access Point. Each attempt consists of approximately 5 seconds of active time followed by 3 seconds of idle time. After 15 cycles (8*15 =120), or about 2 minutes, the scanner stops trying to connect to the base or Access Point, but retains any bar codes that may have been saved in batch mode. After one hour, the scanner powers off and batch mode data is lost. Refer to Auto Reconnect Mode, page 3-28, to review other events that can start the relink process. 3 - 30 Auto Reconnect Mode set to 1 Maximum Link Attempts set to 0 Relink Time-Out set to 10 Scanner Power Time-Out Timer set to 1800 Note: See Scanner Power Time-Out Timer on page 4-7. The scanner attempts to connect to the base or Access Point every 15 seconds, measured from one attempt start to the next attempt start. After one half hour, the scanner powers off. Host Command Acknowledgment Some applications require that the host terminal (or server) approve or reject incoming bar code data and notify the operator of these actions. These applications require that the host maintain control over the response indicators emitted from the scanner. Turning on Host ACK configures the scanner to respond to commands from the host system. Note: System performance degrades when using Host ACK at rates lower than 9600 baud. The following criteria must be met for the Host ACK to work correctly: • The cordless system must be configured for Host Port RS232 (terminal ID = 000) or USB COM Emulation (terminal ID = 130). • RTS/CTS is defaulted off. You must enable it if the host system requires it. • Host ACK must be set to On (page 3-32). • The host terminal software must be capable of interpreting the bar code data, make decisions based on the data content, and send out appropriate escape commands to the scanner. Escape commands are addressed to the scanner via “Application Work Groups.” Once a command is sent, all scanners in a group respond to that command. Because of this, it is recommended that each scanner is assigned to its own group in Host ACK mode. The commands to which the scanner responds are listed on page 3-32. Theis a 1B in hex. A typical command string is y x, where “y” is the application work group number, “ x” is the escape command, and the comma is the terminator, which is required. Commands may be strung together to create custom response sequences. An example of a command string is listed below. 0 4 5 6, The above example will make a scanner in application work group zero beep low, then medium, then high. Once Host ACK is enabled, the system works as follows: • The scanner reads a code and sends data to the base or Access Point to transmit to the host system. No audible or visual indication is emitted until the scanner receives an escape command. The scanner read illumination goes out when there’s a successful read. 3 - 31 • Scanner operation is suspended until 1) a valid escape string is received from the host system (via the base or Access Point) or 2) the scanner times out. • Once condition 1 or 2 above has been met, the scanner is ready to scan again, and the process repeats. A time-out occurs if the scanner does not receive a valid escape command within 10 seconds. A time-out is indicated by an error tone. If a time-out occurs, the operator should check the host system to understand why a response to the scanner was not received. Host ACK On/Off Host ACK On * Host ACK Off Host ACK Responses Command Action a Double beeps to indicate a successful menu change was made. b Razz or error tone to indicate a menu change was unsuccessful. 1 The green LED illuminates for 135 milliseconds followed by a pause. 2 The green LED illuminates for 2 seconds followed by a pause. 3 The green LED illuminates for 5 seconds followed by a pause. 4 Emits a beep at a low pitch. 5 Emits a beep at a medium pitch. 6 Emits a beep at a high pitch. 7 Beeps to indicate a successful decode and communication to host. 3 - 32 Command Action 8 Razz or error tone to indicate a decode/communication to host was unsuccessful. 3 - 33 3 - 34 4 Input/Output Settings Power Up Beeper The scanner can be programmed to beep when it’s powered up. If you are using a cordless system, the base can also be programmed to beep when it is powered up. Scan the Off bar code(s) if you don’t want a power up beep. Default = Power Up Beeper On - Scanner. Power Up Beeper Off Scanner * Power Up Beeper On Scanner Power Up Beeper Off Cordless Base Power Up Beeper On Cordless Base Beep on BEL Character You may wish to force the scanner to beep upon a command sent from the host. If you scan the Beep on BEL On bar code below, the scanner will beep every time a BEL character is received from the host. Default = Beep on BEL Off. *Beep on BEL Off Beep on BEL On 4-1 Trigger Click To hear an audible click every time the scanner trigger is pressed, scan the Trigger Click On bar code below. Scan the Trigger Click Off code if you don’t wish to hear the click. (This feature has no effect on serial or automatic triggering.) Default = Trigger Click Off. *Trigger Click Off Trigger Click On Good Read and Error Indicators Beeper – Good Read The beeper may be programmed On or Off in response to a good read. Turning this option off, only turns off the beeper response to a good read indication. All error and menu beeps are still audible. Default = Beeper Good Read On. Beeper - Good Read Off * Beeper - Good Read On 4-2 Beeper Volume – Good Read The beeper volume codes modify the volume of the beep the scanner emits on a good read. Default = High. Low Medium * High Off Beeper Pitch – Good Read The beeper pitch codes modify the pitch (frequency) of the beep the scanner emits on a good read. Default = Medium. Low (1600 Hz) * Medium (2700 Hz) High (4200 Hz) 4-3 Beeper Pitch – Error The beeper pitch codes modify the pitch (frequency) of the sound the scanner emits when there is a bad read or error. Default = Razz. * Razz (250 Hz) Medium (3250 Hz) High (4200 Hz) Beeper Duration – Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read. Default = Normal. * Normal Beep Short Beep LED – Good Read The LED indicator can be programmed On or Off in response to a good read. Default = On. * LED - Good Read On LED - Good Read Off 4-4 Number of Beeps – Good Read The number of beeps of a good read can be programmed from 1 - 9. The same number of beeps will be applied to the beeper and LED in response to a good read. For example, if you program this option to have five beeps, there will be five beeps and five LED flashes in response to a good read. The beeps and LED flashes are in sync with one another. To change the number of beeps, scan the bar code below and then scan a digit (1-9) bar code and the Save bar code on the Programming Chart inside the back cover of this manual. Default = 1. Number of Good Read Beeps/LED Flashes Number of Beeps – Error The number of beeps and LED flashes emitted by the scanner for a bad read or error can be programmed from 1 - 9. For example, if you program this option to have five error beeps, there will be five error beeps and five LED flashes in response to an error. To change the number of error beeps, scan the bar code below and then scan a digit (1-9) bar code and the Save bar code on the Programming Chart inside the back cover of this manual. Default = 1. Number of Error Beeps/LED Flashes 4-5 Good Read Delay This sets the minimum amount of time before the scanner can read another bar code. Default = 0 ms (No Delay). * No Delay Short Delay (500 ms) Medium Delay (1,000 ms) Long Delay (1,500 ms) User-Specified Good Read Delay If you want to set your own length for the good read delay, scan the bar code below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save. User-Specified Good Read Delay Manual Trigger Modes When in manual trigger mode, the scanner scans until a bar code is read, or until the trigger is released. Two modes are available, Normal and Enhanced. Normal mode offers good scan speed and the longest working ranges (depth of field). Enhanced mode will give you the highest possible scan speed but 4-6 slightly less range than Normal mode. Enhanced mode is best used when you require a very fast scan speed and don’t require a long working range. Default = Manual Trigger-Normal. * Manual Trigger - Normal Manual Trigger - Enhanced Serial Trigger Mode You can activate the scanner either by pressing the trigger, or using a serial trigger command (see Trigger Commands on page 11-4). When in serial mode, the scanner scans until a bar code has been read or until the deactivate command is sent. The scanner can also be set to turn itself off after a specified time has elapsed (see Read Time-Out, which follows). Read Time-Out Use this selection to set a time-out (in milliseconds) of the scanner’s trigger when using serial commands to trigger the scanner. Once the scanner has timed out, you can activate the scanner either by pressing the trigger or using a serial trigger command. After scanning the Read Time-Out bar code, set the time-out duration (from 0-300,000 milliseconds) by scanning digits on the Programming Chart inside the back cover, then scanning Save. Default = 30,000 ms. Read Time-Out Scanner Power Time-Out Timer Note: Scanner Power Time-out Timer only applies to cordless systems. It does not apply to corded scanners. When there is no activity within a specified time period, the scanner enters low power mode. Scan the appropriate scanner power time-out bar code to change the time-out duration (in seconds). Note: Scanning zero (0) is the equivalent of setting no time-out. 4-7 If there are no trigger pulls during the timer interval, the scanner goes into power down mode. Whenever the trigger is enabled, the timer is reset. If the scanner is placed in the charge base cradle and the battery is in the process of being charged, the scanner will not go into power down mode. Default = 3600 seconds. 0 seconds 200 seconds 400 seconds 900 seconds * 3600 seconds 7200 seconds Note: When the scanner is in power down mode, pull the trigger to power the unit back up. There will be a set of power up beeps and a delay of up to a few seconds for the radio to join. The scanner will then be ready to use. 4-8 Presentation Mode Presentation Mode uses ambient light to detect bar codes. The LEDs remain off until a bar code is presented to the scanner, then the LEDs turn on automatically to read the code. If the light level in the room is not high enough, Presentation Mode may not work properly. Note: If you are using a cordless charge base in Presentation Mode, the battery will not charge unless the power supply is plugged into the base’s auxiliary power port. Presentation Mode Presentation LED Behavior after Decode When a scanner is in presentation mode, the LEDs dim 30 seconds after a bar code is decoded. If you wish to dim the LEDs immediately after a bar code is decoded, scan the LEDs Off bar code, below. Default = LEDs On. * LEDs On LEDs Off Presentation Sensitivity Presentation Sensitivity is a numeric range that increases or decreases the scanner's reaction time to bar code presentation. To set the sensitivity, scan the Sensitivity bar code, then scan the degree of sensitivity (from 020) from the inside back cover, and Save. 0 is the most sensitive setting, and 20 is the least sensitive. Default = 1. Sensitivity 4-9 Presentation Centering Use Presentation Centering to narrow the scanner’s field of view when it is in the stand to make sure the scanner reads only those bar codes intended by the user. For instance, if multiple codes are placed closely together, Presentation Centering will insure that only the desired codes are read. Note: To adjust centering when the scanner is hand-held, see Centering (page 4-17). If a bar code is not touched by a predefined window, it will not be decoded or output by the scanner. If Presentation Centering is turned on by scanning Presentation Centering On, the scanner only reads codes that pass through the centering window you specify using the Top of Presentation Centering Window, Bottom of Presentation Centering Window, Left, and Right of Presentation Centering Window bar codes. In the example below, the white box is the centering window. The centering window has been set to 20% left, 30% right, 8% top, and 25% bottom. Since Bar Code 1 passes through the centering window, it will be read. Bar Code 2 does not pass through the centering window, so it will not be read. 0% Bar Code 1 10 Bar Code 2 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100% Note: A bar code needs only to be touched by the centering window in order to be read. It does not need to pass completely through the centering window. 4 - 10 Scan Presentation Centering On, then scan one of the following bar codes to change the top, bottom, left, or right of the centering window. Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual. Scan Save. Default Presentation Centering = 40% for Top and Left, 60% for Bottom and Right. Presentation Centering On * Presentation Centering Off Top of Presentation Centering Window Bottom of Presentation Centering Window Left of Presentation Centering Window Right of Presentation Centering Window In-Stand Sensor Mode This feature senses when the scanner is removed from the stand and tells it to begin manual triggering. When Sensor On is enabled, the scanner defaults to Streaming Presentation Mode when it is in the stand, and to Manual Trigger Mode when it is removed from the stand. Default = Sensor On. * Sensor On Sensor Off Note: If you are taking images (see Imaging Commands beginning on page 81), you must set the In-Stand Sensor to Off. 4 - 11 You may program a Streaming Presentation Mode (Normal, Enhanced, or Mobile Phone) you wish to use for in-stand scanning, and a Manual Trigger mode (Normal, Enhanced, or Mobile Phone) you wish to use for out-of-stand scanning. To do this, you must first scan the preferred Streaming Presentation mode (see below), then scan the Manual Trigger mode (see page 4-6 and page 4-13) you want to use. CodeGate® When CodeGate is On, the trigger is used to allow decoded data to be transmitted to the host system. The scanner remains on, scanning and decoding bar codes, but the bar code data is not transmitted until the trigger is pressed. When CodeGate is Off, bar code data is transmitted when it is decoded. Default = CodeGate Off Out-of-Stand. * CodeGate Off Out-of-Stand CodeGate On Out-of-Stand Streaming Presentation™ Mode When in Streaming Presentation mode, the scanner’s aimer goes out after a short time, but the scan illumination remains on all the time to continuously search for bar codes. Two modes are available, Normal and Enhanced. Normal mode offers good scan speed and the longest working ranges (depth of field). Enhanced mode will give you the highest possible scan speed but slightly less range than Normal mode. Enhanced mode is best used when you require a very fast scan speed and don’t require a long working range. Streaming Presentation Mode - Normal Streaming Presentation Mode - Enhanced When using Preferred Symbology (page 4-19), a lower priority symbol must be centered on the aiming pattern to be read in Streaming Presentation Mode. 4 - 12 You cannot take images when in Streaming Presentation Mode. To take images, scan Image Snap and Ship (see page 4-14). Note: If you are using a cordless charge base, it must have an external power supply plugged into the aux port for Streaming Presentation to work properly. Streaming Presentation In-Stand Programming This option is available when using In-Stand Sensor Mode, page 4-11. You may program a specific Streaming Presentation Mode for in-stand scanning, and a Manual Trigger mode for out-of-stand scanning. To do this, you must first scan the preferred Streaming Presentation mode (Normal, Enhanced, or Mobile Phone), then scan the Manual Trigger mode (Normal, Enhanced, or Mobile Phone) you want to use. Mobile Phone Read Mode When this mode is selected, your scanner is optimized to read bar codes from mobile phone or other LED displays. However, the speed of scanning printed bar codes may be slightly lower when this mode is enabled. You can enable Mobile Phone Reading for either a hand held device, or for a hands-free (presentation) application. Hand Held Scanning - Mobile Phone Streaming Presentation Mobile Phone Note: To turn off Mobil Phone Read Mode, scan a Manual or Serial Trigger Mode bar code (see page 4-6). 4 - 13 Image Snap and Ship Image Snap and Ship tells the scanner to take a picture (rather than read a bar code) when the trigger is pressed. Once the picture is snapped, it is shipped to the host system as a jpeg file by default. To revert to bar code reading, you must change to a different trigger mode (see Manual Trigger Modes beginning on page 4-6). Image Snap and Ship Note: You must use an RS232 interface to use this code. Otherwise, menu codes will not work until you send a serial command for Manual Trigger Modes (see page 11-18). Hands Free Time-Out The Scan Stand and Presentation Modes are referred to as “hands free” modes. If the scanner’s trigger is pulled when using a hands free mode, the scanner changes to manual trigger mode. You can set the time the scanner should remain in manual trigger mode by setting the Hands Free Time-Out. Once the time-out value is reached, (if there have been no further trigger pulls) the scanner reverts to the original hands free mode. Scan the Hands Free Time-Out bar code, then scan the time-out duration (from 0-300,000 milliseconds) from the inside back cover, and Save. Default = 5,000 ms. Hands Free Time-Out Reread Delay This sets the time period before the scanner can read the same bar code a second time. Setting a reread delay protects against accidental rereads of the same bar code. Longer delays are effective in minimizing accidental rereads. 4 - 14 Use shorter delays in applications where repetitive bar code scanning is required. Reread Delay only works when in Presentation Mode (see page 4-9). Default = Medium. Short (500 ms) * Medium (750 ms) Long (1000 ms) Extra Long (2000 ms) User-Specified Reread Delay If you want to set your own length for the reread delay, scan the bar code below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save. User-Specified Reread Delay Illumination Lights If you want the illumination lights on while reading a bar code, scan the Lights On bar code, below. However, if you want to turn just the lights off, scan the Lights Off bar code. Default = Lights On. Note: This setting does not affect the aimer light. The aiming light can be set using Aimer Mode (page 4-17). * Lights On Lights Off 4 - 15 Aimer Delay The aimer delay allows a delay time for the operator to aim the scanner before the picture is taken. Use these codes to set the time between when the trigger is pulled and when the picture is taken. During the delay time, the aiming light will appear, but the LEDs won’t turn on until the delay time is over. Default = Off. 200 milliseconds 400 milliseconds * Off (no delay) User-Specified Aimer Delay If you want to set your own length for the duration of the delay, scan the bar code below, then set the time-out by scanning digits (0 - 4,000 ms) from the Programming Chart inside the back cover of this manual, then scan Save. Delay Duration Scanner Time-Out Note: Scanner Time-Out applies only to corded scanners. It does not apply to cordless systems. Scanner Time-Out powers down the scanner after the unit has been idle for the specified time. To prevent the scanner from powering down, set this time-out to 0. Scan Scanner Time-Out, then set the time-out by scanning digits (from 0 999,999 ms) from the inside back cover, then scanning Save. Default = 1 ms. Scanner Time-Out 4 - 16 Aimer Mode This feature allows you to turn the aimer on and off. When the Interlaced bar code is scanned, the aimer is interlaced with the illumination LEDs. Default = Interlaced. Off * Interlaced Centering Use Centering to narrow the scanner’s field of view to make sure that when the scanner is hand-held, it reads only those bar codes intended by the user. For instance, if multiple codes are placed closely together, centering will insure that only the desired codes are read. (Centering can be used in conjunction with Aimer Delay, page 4-16, for the most error-free operation in applications where multiple codes are spaced closely together. Using the Aimer Delay and Centering features, the scanner can emulate the operation of older systems, such as linear laser bar code scanners.) Note: To adjust centering when the scanner is in the stand, see Presentation Centering (page 4-10). If a bar code is not touched by a predefined window, it will not be decoded or output by the scanner. If centering is turned on by scanning Centering On, the scanner only reads codes that pass through the centering window you specify using the Top of Centering Window, Bottom of Centering Window, Left, and Right of Centering Window bar codes. 4 - 17 In the example below, the white box is the centering window. The centering window has been set to 20% left, 30% right, 8% top, and 25% bottom. Since Bar Code 1 passes through the centering window, it will be read. Bar Code 2 does not pass through the centering window, so it will not be read. 0% Bar Code 1 10 Bar Code 2 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100% Note: A bar code needs only to be touched by the centering window in order to be read. It does not need to pass completely through the centering window. 4 - 18 Scan Centering On, then scan one of the following bar codes to change the top, bottom, left, or right of the centering window. Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual. Scan Save. Default Centering = 40% for Top and Left, 60% for Bottom and Right. Centering On * Centering Off Top of Centering Window Bottom of Centering Window Left of Centering Window Right of Centering Window Preferred Symbology The scanner can be programmed to specify one symbology as a higher priority over other symbologies in situations where both bar code symbologies appear on the same label, but the lower priority symbology cannot be disabled. For example, you may be using the scanner in a retail setting to read U.P.C. symbols, but have occasional need to read a code on a drivers license. Since some licenses have a Code 39 symbol as well as the PDF417 symbol, you can use Preferred Symbology to specify that the PDF417 symbol be read instead of the Code 39. Preferred Symbology classifies each symbology as high priority, low priority, or as an unspecified type. When a low priority symbology is presented, the scanner ignores it for a set period of time (see Preferred Symbology Time-out on page 4-20) while it searches for the high priority symbology. If a high priority symbology is located during this period, then that data is read immediately. If the time-out period expires before a high priority symbology is read, the scanner will read any bar code in its view (low priority or unspecified). If there is no bar code in the scanner’s view after the time-out period expires, then no data is reported. Note: A low priority symbol must be centered on the aiming pattern to be read. 4 - 19 Scan a bar code below to enable or disable Preferred Symbology. Preferred Symbology Off. Default = Preferred Symbology On * Preferred Symbology Off High Priority Symbology To specify the high priority symbology, scan the High Priority Symbology bar code below. On the Symbology Chart on page A-1, find the symbology you want to set as high priority. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart (inside back cover). Scan Save to save your selection. Default = None High Priority Symbology Low Priority Symbology To specify the low priority symbology, scan the Low Priority Symbology bar code below. On the Symbology Chart on page A-1, find the symbology you want to set as low priority. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart (inside back cover). If you want to set additional low priority symbologies, scan FF, then scan the 2 digit hex value from the Programming Chart for the next symbology. You can program up to 5 low priority symbologies. Scan Save to save your selection. Default = None Low Priority Symbology Preferred Symbology Time-out Once you have enabled Preferred Symbology and entered the high and low priority symbologies, you must set the time-out period. This is the period of time the scanner will search for a high priority bar code after a low priority 4 - 20 bar code has been encountered. Scan the bar code below, then set the delay (from 1-3,000 milliseconds) by scanning digits from the inside back cover, then scanning Save. Default = 500 ms. Preferred Symbology Time-out Preferred Symbology Default Scan the bar code below to set all Preferred Symbology entries to their default values. Preferred Symbology Default Output Sequence Overview Require Output Sequence When turned off, the bar code data will be output to the host as the scanner decodes it. When turned on, all output data must conform to an edited sequence or the scanner will not transmit the output data to the host device. Note: This selection is unavailable when the Multiple Symbols Selection is turned on. Output Sequence Editor This programming selection allows you to program the scanner to output data (when scanning more than one symbol) in whatever order your application requires, regardless of the order in which the bar codes are scanned. Reading the Default Sequence symbol programs the scanner to the Universal values, shown below. These are the defaults. Be certain you want to delete or clear all formats before you read the Default Sequence symbol. Note: To make Output Sequence Editor selections, you’ll need to know the code I.D., code length, and character match(es) your application requires. Use the Alphanumeric symbols (inside back cover) to read these options. You must hold the trigger while reading each bar code in the sequence. 4 - 21 To Add an Output Sequence 1. Scan the Enter Sequence symbol (see Require Output Sequence, page 4-25). 2. Code I.D. On the Symbology Chart on page A-1, find the symbology to which you want to apply the output sequence format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart (inside back cover). 3. Length Specify what length (up to 9999 characters) of data output will be acceptable for this symbology. Scan the four digit data length from the Programming Chart. (Note: 50 characters is entered as 0050. 9999 is a universal number, indicating all lengths.) When calculating the length, you must count any programmed prefixes, suffixes, or formatted characters as part of the length (unless using 9999). 4. Character Match Sequences On the ASCII Conversion Chart (Code Page 1252), page A-4, find the Hex value that represents the character(s) you want to match. Use the Programming Chart to read the alphanumeric combination that represents the ASCII characters. (99 is the Universal number, indicating all characters.) 5. End Output Sequence Editor Scan F F to enter an Output Sequence for an additional symbology, or Save to save your entries. Other Programming Selections • Discard This exits without saving any Output Sequence changes. 4 - 22 Output Sequence Example In this example, you are scanning Code 93, Code 128, and Code 39 bar codes, but you want the scanner to output Code 39 1st, Code 128 2nd, and Code 93 3rd, as shown below. Note: Code 93 must be enabled to use this example. A - Code 39 B - Code 128 C - Code 93 You would set up the sequence editor with the following command line: SEQBLK62999941FF6A999942FF69999943FF The breakdown of the command line is shown below: SEQBLKsequence editor start command 62 code identifier for Code 39 9999 code length that must match for Code 39, 9999 = all lengths 41 start character match for Code 39, 41h = “A” FF termination string for first code 6A code identifier for Code 128 9999 code length that must match for Code 128, 9999 = all lengths 42 start character match for Code 128, 42h = “B” FF termination string for second code 69 code identifier for Code 93 9999 code length that must match for Code 93, 9999 = all lengths 43 start character match for Code 93, 43h = “C” FF termination string for third code To program the previous example using specific lengths, you would have to count any programmed prefixes, suffixes, or formatted characters as part of the length. If you use the example on page 4-23, but assume a suffix and specific code lengths, you would use the following command line: SEQBLK62001241FF6A001342FF69001243FF The breakdown of the command line is shown below: 4 - 23 SEQBLKsequence editor start command 62 code identifier for Code 39 0012 A - Code 39 sample length (11) plus CR suffix (1) = 12 41 start character match for Code 39, 41h = “A” FF termination string for first code 6A code identifier for Code 128 0013 B - Code 128 sample length (12) plus CR suffix (1) = 13 42 start character match for Code 128, 42h = “B” FF termination string for second code 69 code identifier for Code 93 0012 C - Code 93 sample length (11) plus CR suffix (1) = 12 43 start character match for Code 93, 43h = “C” FF termination string for third code Output Sequence Editor Enter Sequence Default Sequence Partial Sequence If an output sequence operation is terminated before all your output sequence criteria are met, the bar code data acquired to that point is a “partial sequence.” Scan Discard Partial Sequence to discard partial sequences when the output sequence operation is terminated before completion. Scan Transmit Partial Sequence to transmit partial sequences. (Any fields in the sequence where no data match occurred will be skipped in the output.) Transmit Partial Sequence * Discard Partial Sequence 4 - 24 Require Output Sequence When an output sequence is Required, all output data must conform to an edited sequence or the scanner will not transmit the output data to the host device. When it’s On/Not Required, the scanner will attempt to get the output data to conform to an edited sequence but, if it cannot, the scanner transmits all output data to the host device as is. When the output sequence is Off, the bar code data is output to the host as the scanner decodes it. Default = Off. Note: This selection is unavailable when the Multiple Symbols Selection is turned on. Required On/Not Required *Off Multiple Symbols When this programming selection is turned On, it allows you to read multiple symbols with a single pull of the scanner’s trigger. If you press and hold the trigger, aiming the scanner at a series of symbols, it reads unique symbols once, beeping (if turned on) for each read. The scanner attempts to find and decode new symbols as long as the trigger is pulled. When this programming selection is turned Off, the scanner will only read the symbol closest to the aiming beam. Default = Off. On * Off 4 - 25 No Read With No Read turned On, the scanner notifies you if a code cannot be read. If using an EZConfig Tool Scan Data Window (see page 10-3), an “NR” appears when a code cannot be read. If No Read is turned Off, the “NR” will not appear. Default = Off. On * Off If you want a different notation than “NR,” for example, “Error,” or “Bad Code,” you can edit the output message (see Data Formatting beginning on page 6-1). The hex code for the No Read symbol is 9C. Video Reverse Video Reverse is used to allow the scanner to read bar codes that are inverted. The Video Reverse Off bar code below is an example of this type of bar code. Scan Video Reverse Only to read only inverted bar codes. Scan Video Reverse and Standard Bar Codes to read both types of codes. Note: After scanning Video Reverse Only, menu bar codes cannot be read. You must scan Video Reverse Off or Video Reverse and Standard Bar Codes in order to read menu bar codes. Note: Images downloaded from the unit are not reversed. This is a setting for decoding only. Video Reverse Only Video Reverse and Standard Bar Codes VIDREV0. * Video Reverse Off 4 - 26 Working Orientation Some bar codes are direction-sensitive. For example, KIX codes and OCR can misread when scanned sideways or upside down. Use the working orientation settings if your direction-sensitive codes will not usually be presented upright to the scanner. Default = Upright. Upright: Vertical, Top to Bottom: (Rotate CW 90°) Upside Down: Vertical, Bottom to Top: (Rotate CCW 90°) Default = Upright. * Upright Vertical, Bottom to Top Upside Down Vertical, Top to Bottom 4 - 27 4 - 28 5 Data Editing Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string. Prefix and Suffix characters are data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with specific symbologies. The following illustration shows the breakdown of a message string: Prefix Scanned Data 1-11 variable length alpha numeric & control characters Suffix 1-11 alpha numeric & control characters Points to Keep In Mind • It is not necessary to build a message string. The selections in this chapter are only used if you wish to alter the default settings. Default prefix = None. Default suffix = None. • A prefix or suffix may be added or cleared from one symbology or all symbologies. • You can add any prefix or suffix from the ASCII Conversion Chart (Code Page 1252), beginning on page A-4, plus Code I.D. and AIM I.D. • You can string together several entries for several symbologies at one time. • Enter prefixes and suffixes in the order in which you want them to appear on the output. • When setting up for specific symbologies (as opposed to all symbologies), the specific symbology ID value counts as an added prefix or suffix character. • The maximum size of a prefix or suffix configuration is 200 characters, which includes header information. To Add a Prefix or Suffix: Step 1. Scan the Add Prefix or Add Suffix symbol (page 5-3). Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in the Symbology Chart, beginning on page A-1) for the 5-1 symbology to which you want to apply the prefix or suffix. For example, for Code 128, Code ID is “j” and Hex ID is “6A”. Step 3. Scan the 2 hex digits from the Programming Chart inside the back cover of this manual or scan 9, 9 for all symbologies. Step 4. Determine the hex value from the ASCII Conversion Chart (Code Page 1252), beginning on page A-4, for the prefix or suffix you wish to enter. Step 5. Scan the 2 digit hex value from the Programming Chart inside the back cover of this manual. Step 6. Repeat Steps 4 and 5 for every prefix or suffix character. Step 7. To add the Code I.D., scan 5, C, 8, 0. To add AIM I.D., scan 5, C, 8, 1. To add a backslash (\), scan 5, C, 5, C. Note: To add a backslash (\) as in Step 7, you must scan 5C twice – once to create the leading backslash and then to create the backslash itself. Step 8. Scan Save to exit and save, or scan Discard to exit without saving. Repeat Steps 1-6 to add a prefix or suffix for another symbology. Example: Add a Suffix to a specific symbology To send a CR (carriage return)Suffix for U.P.C. only: Step 1. Scan Add Suffix. Step 2. Determine the 2 digit hex value from the Symbology Chart (included in the Symbology Chart, beginning on page A-1) for U.P.C.. Step 3. Scan 6, 3 from the Programming Chart inside the back cover of this manual. Step 4. Determine the hex value from the ASCII Conversion Chart (Code Page 1252), beginning on page A-4, for the CR (carriage return). Step 5. Scan 0, D from the Programming Chart inside the back cover of this manual. Step 6. Scan Save, or scan Discard to exit without saving. To Clear One or All Prefixes or Suffixes You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. If you have been entering prefixes and suffixes for single symbologies, you can use Clear One Prefix (Suffix) to delete a specific character from a symbology. When you Clear All Prefixes (Suffixes), all the prefixes or suffixes for a symbology are deleted. 5-2 Step 1. Scan the Clear One Prefix or Clear One Suffix symbol. Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in the Symbology Chart, beginning on page A-1) for the symbology from which you want to clear the prefix or suffix. Step 3. Scan the 2 digit hex value from the Programming Chart inside the back cover of this manual or scan 9, 9 for all symbologies. Your change is automatically saved. To Add a Carriage Return Suffix to All Symbologies Scan the following bar code if you wish to add a carriage return suffix to all symbologies at once. This action first clears all current suffixes, then programs a carriage return suffix for all symbologies. Add CR Suffix All Symbologies Prefix Selections Add Prefix Clear One Prefix Clear All Prefixes 5-3 Suffix Selections Add Suffix Clear One Suffix Clear All Suffixes Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys starting on page 9-3. When the scanner is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted. Default = Enable. * Enable Disable Intercharacter, Interfunction, and Intermessage Delays Some terminals drop information (characters) if data comes through too quickly. Intercharacter, interfunction, and intermessage delays slow the transmission of data, increasing data integrity. 5-4 Intercharacter Delay An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be placed between the transmission of each character of scanned data. Scan the Intercharacter Delay bar code below, then scan the number of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this manual. Prefix Scanned Data 1 2 3 4 Suffix 5 Intercharacter Delay Intercharacter Delay To remove this delay, scan the Intercharacter Delay bar code, then set the number of delays to 0. Scan the Save bar code using the Programming Chart inside the back cover of this manual. Note: Intercharacter delays are not supported in USB serial emulation. User Specified Intercharacter Delay An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be placed after the transmission of a particular character of scanned data. Scan the Delay Length bar code below, then scan the number of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this manual. Next, scan the Character to Trigger Delay bar code, then the 2-digit hex value for the ASCII character that will trigger the delay ASCII Conversion Chart (Code Page 1252), beginning on page A-4. Delay Length Character to Trigger Delay To remove this delay, scan the Delay Length bar code, and set the number of delays to 0. Scan the Save bar code using the Programming Chart inside the back cover of this manual. 5-5 Interfunction Delay An interfunction delay of up to 5000 milliseconds (in 5ms increments) may be placed between the transmission of each segment of the message string. Scan the Interfunction Delay bar code below, then scan the number of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this manual. Prefix STX 1 Scanned Data HT 2 3 4 5 Suffix CR LF Interfunction Delays Interfunction Delay To remove this delay, scan the Interfunction Delay bar code, then set the number of delays to 0. Scan the Save bar code using the Programming Chart inside the back cover of this manual. Intermessage Delay An intermessage delay of up to 5000 milliseconds (in 5ms increments) may be placed between each scan transmission. Scan the Intermessage Delay bar code below, then scan the number of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this manual. 1st Scan Transmission 2nd Scan Transmission Intermessage Delay Intermessage Delay To remove this delay, scan the Intermessage Delay bar code, then set the number of delays to 0. Scan the Save bar code using the Programming Chart inside the back cover of this manual. 5-6 6 Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the scanner’s output. For example, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. The selections in the following pages are used only if you wish to alter the output. Default Data Format setting = None. Normally, when you scan a bar code, it gets outputted automatically; however when you create a format, you must use a “send” command (see Send Commands on page 6-4) within the format program to output data. Multiple formats may be programmed into the scanner. They are stacked in the order in which they are entered. However, the following list presents the order in which formats are applied: 1. 2. 3. 4. 5. 6. 7. 8. Specific Terminal ID, Actual Code ID, Actual Length Specific Terminal ID, Actual Code ID, Universal Length Specific Terminal ID, Universal Code ID, Actual Length Specific Terminal ID, Universal Code ID, Universal Length Universal Terminal ID, Actual Code ID, Actual Length Universal Terminal ID, Actual Code ID, Universal Length Universal Terminal ID, Universal Code ID, Actual Length Universal Terminal ID, Universal Code ID, Universal Length The maximum size of a data format configuration is 2000 bytes, which includes header information. If you have changed data format settings, and wish to clear all formats and return to the factory defaults, scan the Default Data Format code below. * Default Data Format Add a Data Format Step 1. Scan the Enter Data Format symbol (page 6-2). Step 2. Select Primary/Alternate Format Determine if this will be your primary data format, or one of 3 alternate formats. This allows you to save a total of 4 different data formats. To program your primary format, scan 0 using the Programming Chart inside the back cover of this manual. If you are programming an alternate format, scan 1, 2, or 3, depending on which alternate format 6-1 you are programming. (See Primary/Alternate Data Formats on page 6-11 for further information.) Step 3. Terminal Type Refer to Terminal ID Table (page 6-4) and locate the Terminal ID number for your PC. Scan three numeric bar codes on the inside back cover to program the scanner for your terminal ID (you must enter 3 digits). For example, scan 0 0 3 for an AT wedge. Note: The wildcard for all terminal types is 099. Step 4. Code I.D. In the Symbology Chart, beginning on page A-1, find the symbology to which you want to apply the data format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart inside the back cover of this manual. Note: If you wish to create a data format for all symbologies, with the exception of some specific symbologies, refer to B8 (page 6-9). Step 5. Length Specify what length (up to 9999 characters) of data will be acceptable for this symbology. Scan the four digit data length from the Programming Chart inside the back cover of this manual. (Note: 50 characters is entered as 0050. 9999 is a universal number, indicating all lengths.) Step 6. Editor Commands Refer to Data Format Editor Commands (page 6-4). Scan the symbols that represent the command you want to enter. 94 alphanumeric characters may be entered for each symbology data format. Step 7. Scan Save to save your data format, or Discard to exit without saving your changes. Enter Data Format Save Discard 6-2 Other Programming Selections Clear One Data Format This deletes one data format for one symbology. If you are clearing the primary format, scan 0 from the Programming Chart inside the back cover of this manual. If you are clearing an alternate format, scan 1, 2, or 3, depending on the format you are clearing. Scan the Terminal Type and Code I.D. (see Symbology Chart on page A-1), and the bar code data length for the specific data format that you want to delete. All other formats remain unaffected. Clear all Data Formats This clears all data formats. Save to exit and save your data format changes. Discard to exit without saving any data format changes. Clear One Data Format Clear All Data Formats Save Discard 6-3 Terminal ID Table Terminal Model(s) IBM PC/AT and compatibles USB SurePOS Handheld Scanner USB SurePOS Tabletop Scanner True TTL RS232 RS485 USB Serial PC Keyboard Mac Keyboard Japanese Keyboard (PC) HID POS Terminal ID 003 128 129 000 000 051 130 124 125 134 131 Data Format Editor Commands Send Commands Send all characters F1 Include in the output message all of the characters from the input message, starting from current cursor position, followed by an insert character. Syntax = F1xx where xx stands for the insert character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-4 for decimal, hex and character codes. Send a number of characters F2 Include in the output message a number of characters followed by an insert character. Start from the current cursor position and continue for “nn” characters or through the last character in the input message, followed by character “xx.” Syntax = F2nnxx where nn stands for the numeric value (00-99) for the number of characters, and xx stands for the the insert character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-4 for decimal, hex and character codes. Send all characters up to a particular character F3 Include in the output message all characters from the input message, starting with the character at the current cursor position and continuing to, but not including, the search character “ss,” followed by an insert character. The cursor is moved forward to the “ss” character. Syntax = F3ssxx where ss stands for the search character’s hex value for its 6-4 ASCII code, and xx stands for the insert character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-4 for decimal, hex and character codes. Send all but the last characters E9 Include in the output message all but the last “nn” characters, starting from the current cursor position. The cursor is moved forward to one position past the last input message character included. Syntax = E9nn where nn stands for the numeric value (00-99) for the number of characters that will not be sent at the end of the message. Insert a character multiple times F4 Send “xx” character “nn” times in the output message, leaving the cursor in the current position. Syntax = F4xxnn where xx stands for the insert character’s hex value for its ASCII code, and nn is the numeric value (00-99) for the number of times it should be sent. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-4 for decimal, hex and character codes. Insert symbology name B3 Insert the name of the bar code’s symbology in the output message, without moving the cursor. Only symbologies with a Honeywell ID are included (see Symbology Chart on page A-1). Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-4 for decimal, hex and character codes. Insert bar code length B4 Insert the bar code’s length in the output message, without moving the cursor. The length is expressed as a numeric string and does not include leading zeroes. Insert key strokes B5 Insert a key stroke or combination of key strokes. Key strokes are dependent on your keyboard (see Unicode Key Maps on page A-8). Any key can be inserted, including arrows and functions. Syntax = B5xxssnn where xx is the number of keys pressed (without key modifiers), ss is the key modifier from the table below, and nn is the key number from the Unicode Key Maps, page A-8. Key Modifiers No Key Modifier Shift Left Shift Right Alt Left Alt Right 00 01 02 04 08 6-5 Key Modifiers Control Left Control Right 10 20 For example, B501021F inserts an “A” on a 104 key, U.S. style keyboard. B5 = the command, 01 = number of keys pressed (without the key modifier), 02 is the key modifier for Shift Right, and 1F is the “a” key. If a lower case “a” were to be inserted, B501001F would be entered. If there are three keystrokes, the syntax would change from B5xxssnn for one keystroke to B5xxssnnssnnssnn. An example that would insert "abc" is as follows: B503001F00320030F833. Note: Key modifiers can be added together when needed. Example: Control Left+Shift Left = 11. Move Commands Move the cursor forward a number of characters F5 Move the cursor ahead “nn” characters from current cursor position. Syntax = F5nn where nn is the numeric value (00-99) for the number of characters the cursor should be moved ahead. Move the cursor backward a number of characters F6 Move the cursor back “nn” characters from current cursor position. Syntax = F6nn where nn is the numeric value (00-99) for the number of characters the cursor should be moved back. Move the cursor to the beginning F7 Move the cursor to the first character in the input message. Syntax = F7. Move the cursor to the end EA Move the cursor to the last character in the input message. Syntax = EA. Search Commands Search forward for a character F8 Search the input message forward for “xx” character from the current cursor position, leaving the cursor pointing to the “xx” character. Syntax = F8xx where xx stands for the search character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-4 for decimal, hex and character codes. 6-6 Search backward for a character F9 Search the input message backward for “xx” character from the current cursor position, leaving the cursor pointing to the “xx” character. Syntax = F9xx where xx stands for the search character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-4 for decimal, hex and character codes. Search forward for a string B0 Search forward for “s” string from the current cursor position, leaving cursor pointing to “s” string. Syntax = B0nnnnS where nnnn is the string length (up to 9999), and S consists of the ASCII hex value of each character in the match string. For example, B0000454657374 will search forward for the first occurrence of the 4 character string “Test.” Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-4 for decimal, hex and character codes. Search backward for a string B1 Search backward for “s” string from the current cursor position, leaving cursor pointing to “s” string. Syntax = B1nnnnS where nnnn is the string length (up to 9999), and S consists of the ASCII hex value of each character in the match string. For example, B1000454657374 will search backward for the first occurrence of the 4 character string “Test.” Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-4 for decimal, hex and character codes. Search forward for a non-matching character E6 Search the input message forward for the first non-“xx” character from the current cursor position, leaving the cursor pointing to the non-“xx” character. Syntax = E6xx where xx stands for the search character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-4 for decimal, hex and character codes. Search backward for a non-matching character E7 Search the input message backward for the first non-“xx” character from the current cursor position, leaving the cursor pointing to the non“xx” character. Syntax = E7xx where xx stands for the search character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-4 for decimal, hex and character codes. 6-7 Miscellaneous Commands Suppress characters FB Suppress all occurrences of up to 15 different characters, starting at the current cursor position, as the cursor is advanced by other commands. When the FC command is encountered, the suppress function is terminated. The cursor is not moved by the FB command. Syntax = FBnnxxyy . .zz where nn is a count of the number of suppressed characters in the list, and xxyy .. zz is the list of characters to be suppressed. Stop suppressing characters FC Disables suppress filter and clear all suppressed characters. Syntax = FC. Replace characters E4 Replaces up to 15 characters in the output message, without moving the cursor. Replacement continues until the E5 command is encountered. Syntax = E4nnxx1xx2yy1yy2...zz1zz2 where nn is the total count of of the number of characters in the list (characters to be replaced plus replacement characters); xx1 defines characters to be replaced and xx2 defines replacement characters, continuing through zz1 and zz2. Stop replacing characters E5 Terminates character replacement. Syntax = E5. Compare characters FE Compare the character in the current cursor position to the character “xx.” If characters are equal, move the cursor forward one position. Syntax = FExx where xx stands for the comparison character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-4 for decimal, hex and character codes. Compare string B2 Compare the string in the input message to the string “s.” If the strings are equal, move the cursor forward past the end of the string. Syntax = B2nnnnS where nnnn is the string length (up to 9999), and S consists of the ASCII hex value of each character in the match string. For example, B2000454657374 will compare the string at the current cursor position with the 4 character string “Test.” Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-4 for decimal, hex and character codes. Check for a number EC Check to make sure there is an ASCII number at the current cursor position. The format is aborted if the character is not numeric. 6-8 Check for non-numeric character ED Check to make sure there is a non-numeric ASCII character at the current cursor position. The format is aborted if the character is numeric. Insert a delay EF Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting from the current cursor position. Syntax = EFnnnn where nnnn stands for the delay in 5ms increments, up to 9999. This command can only be used with keyboard wedge interfaces. Discard Data B8 Discards types of data. For example, you may want to discard Code 128 bar codes that begin with the letter A. In step 4 (page 6-2), select 6A (for Code 128), and in step 5, select 9999 (for all lengths). Enter B8FE41 to compare and discard Code 128 bar codes that begin with the letter A. Syntax = B8. Note: Other data format settings impact the B8 command. If Data Format Non-Match Error Tone is On (page 6-11), the scanner emits an error tone. If Data format Non-Match Error Tone is Off, the code is disabled for reading and no tone is sounded. If Data Format is On, but Not Required (page 6-10), bar code data that meets the B8 format is scanned and output as usual. Data Formatter When Data Formatter is turned Off, the bar code data is output to the host as read, including prefixes and suffixes. Data Formatter Off You may wish to require the data to conform to a data format you have created and saved. The following settings can be applied to your data format: Data Formatter On, Not Required, Keep Prefix/Suffix Scanned data is modified according to your data format, and prefixes and suffixes are transmitted. Data Formatter On, Not Required, Drop Prefix/Suffix Scanned data is modified according to your data format. If a data format is found for a particular symbol, those prefixes and suffixes are not transmitted. If a data format is not found for that symbol, the prefixes and suffixes are transmitted. 6-9 Data Format Required, Keep Prefix/Suffix Scanned data is modified according to your data format, and prefixes and suffixes are transmitted. Any data that does not match your data format requirements generates an error tone and the data in that bar code is not transmitted. If you wish to process this type of bar code without generating an error tone, see Data Format Non-Match Error Tone. Data Format Required, Drop Prefix/Suffix Scanned data is modified according to your data format. If a data format is found for a particular symbol, those prefixes and suffixes are not transmitted. Any data that does not match your data format requirements generates an error tone. If you wish to process this type of bar code without generating an error tone, see Data Format Non-Match Error Tone. Choose one of the following options. Default = Data Formatter On, Not Required, Keep Prefix/Suffix. * Data Formatter On, Not Required, Keep Prefix/Suffix Data Formatter On, Not Required, Drop Prefix/Suffix Data Format Required, Keep Prefix/Suffix Data Format Required, Drop Prefix/Suffix Data Format Non-Match Error Tone When a bar code is encountered that doesn’t match your required data format, the scanner normally generates an error tone. However, you may want to continue scanning bar codes without hearing the error tone. If you scan the Data Format Non-Match Error Tone Off bar code, data that doesn’t conform to your data format is not transmitted, and no error tone 6 - 10 will sound. If you wish to hear the error tone when a non-matching bar code is found, scan the Data Format Non-Match Error Tone On bar code. Default = Data Format Non-Match Error Tone On. * Data Format Non-Match Error Tone On Data Format Non-Match Error Tone Off Primary/Alternate Data Formats You can save up to four data formats, and switch between these formats. Your primary data format is saved under 0. Your other three formats are saved under 1, 2, and 3. To set your device to use one of these formats, scan one of the bar codes below. Primary Data Format Data Format 1 Data Format 2 Data Format 3 Single Scan Data Format Change You can also switch between data formats for a single scan. The next bar code is scanned using an alternate data format, then reverts to the format you have selected above (either Primary, 1, 2, or 3). 6 - 11 For example, you may have set your device to the data format you saved as Data Format 3. You can switch to Data Format 1 for a single trigger pull by scanning the Single Scan-Data Format 1 bar code below. The next bar code that is scanned uses Data Format 1, then reverts back to Data Format 3. Single Scan-Primary Data Format Single Scan-Data Format 1 Single Scan-Data Format 2 Single Scan-Data Format 3 6 - 12 7 Symbologies This programming section contains the following menu selections. Refer to Chapter 11 for settings and defaults. • All Symbologies • Interleaved 2 of 5 • Aztec Code • Korea Post • China Post (Hong Kong 2 of 5) • Matrix 2 of 5 • Chinese Sensible (Han Xin) Code • MaxiCode • Codabar • MicroPDF417 • Codablock A • MSI • Codablock F • NEC 2 of 5 • Code 11 • Postal Codes - 2D • Code 128 • Postal Codes - Linear • Code 32 Pharmaceutical (PARAF) • PDF417 • Code 39 • GS1 DataBar Omnidirectional • Code 93 • QR Code • Data Matrix • Straight 2 of 5 IATA (two-bar start/ stop) • EAN/JAN-13 • Straight 2 of 5 Industrial (three-bar start/stop) • EAN/JAN-8 • TCIF Linked Code 39 (TLC39) • GS1 Composite Codes • Telepen • GS1 DataBar Expanded • Trioptic Code • GS1 DataBar Limited • UPC-A • GS1 DataBar Omnidirectional • UPC-A/EAN-13 with Extended Coupon Code • GS1 Emulation • UPC-E0 • GS1-128 • UPC-E1 7-1 All Symbologies If you want to decode all the symbologies allowable for your scanner, scan the All Symbologies On code. If on the other hand, you want to decode only a particular symbology, scan All Symbologies Off followed by the On symbol for that particular symbology. All Symbologies On All Symbologies Off Note: When All Symbologies On is scanned, 2D Postal Codes are not enabled. 2D Postal Codes must be enabled separately. Message Length Description You are able to set the valid reading length of some of the bar code symbologies. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will issue an error tone. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes included in the explanation of the symbology, then scan the digit value of the message length and Save bar codes on the Programming Chart inside the back cover of this manual. The minimum and maximum lengths and the defaults are included with the respective symbologies. 7-2 Codabar Codabar On/Off * On Off Codabar Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit. Transmit * Don’t Transmit Codabar Check Character Codabar check characters are created using different “modulos.” You can program the scanner to read only Codabar bar codes with Modulo 16 check characters. Default = No Check Character. No Check Character indicates that the scanner reads and transmits bar code data with or without a check character. When Check Character is set to Validate and Transmit, the scanner will only read Codabar bar codes printed with a check character, and will transmit this character at the end of the scanned data. 7-3 When Check Character is set to Validate, but Don’t Transmit, the unit will only read Codabar bar codes printed with a check character, but will not transmit the check character with the scanned data. * No Check Character Validate Modulo 16, but Don’t Transmit Validate Modulo 16 and Transmit Codabar Concatenation Codabar supports symbol concatenation. When you enable concatenation, the scanner looks for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character. In this case the two messages are concatenated into one with the “D” characters omitted. A 1 2 3 4 D D 5 6 7 8 A Select Require to prevent the scanner from decoding a single “D” Codabar symbol without its companion. This selection has no effect on Codabar symbols without Stop/Start D characters. On * Off Require 7-4 Codabar Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60. Minimum Message Length Maximum Message Length 7-5 Code 39 < Default All Code 39 Settings > Code 39 On/Off * On Off Code 39 Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit. Transmit * Don’t Transmit Code 39 Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character. When Check Character is set to Validate, but Don’t Transmit, the unit only reads Code 39 bar codes printed with a check character, but will not transmit the check character with the scanned data. 7-6 When Check Character is set to Validate and Transmit, the scanner only reads Code 39 bar codes printed with a check character, and will transmit this character at the end of the scanned data. Default = No Check Character. * No Check Character Validate, but Don’t Transmit Validate and Transmit Code 39 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 0-48. Minimum Default = 0, Maximum Default = 48. Minimum Message Length Maximum Message Length Code 39 Append This function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to the host computer. When the scanner encounters a Code 39 bar code with the append trigger char- 7-7 acter(s), it buffers Code 39 bar codes until it reads a Code 39 bar code that does not have the append trigger. The data is then transmitted in the order in which the bar codes were read (FIFO). Default = Off. On * Off Code 32 Pharmaceutical (PARAF) Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies. This symbology is also known as PARAF. Note: Trioptic Code (page 7-40) must be turned off while scanning Code 32 Pharmaceutical codes. On * Off 7-8 Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. Default = Off. NUL %U DLE $P SP SPACE 0 0 @ %V P P ‘ %W p +P SOH $A DC1 $Q ! /A 1 1 A A Q Q a +A q +Q STX $B DC2 $R “ /B 2 2 B B R R b +B r +R ETX $C DC3 $S # /C 3 3 C C S S c +C s +S EOT $D DC4 $T $ /D 4 4 D D T T d +D t +T ENQ $E NAK $U % /E 5 5 E E U U e +E u +U ACK $F SYN $V & /F 6 6 F F V V f +F v +V BEL $G ETB $W ‘ /G 7 7 G G W W g +G w +W BS $H CAN $X ( /H 8 8 H H X X h +H x +X HT $I EM $Y ) /I 9 9 I I Y Y i +I y +Y LF $J SUB $Z * /J : /Z J J Z Z j +J z +Z VT $K ESC %A + /K ; %F K K [ %K k +K { %P FF $L FS %B , /L < %G L L \ %L l +L | %Q CR $M GS %C - - = %H M M ] %M m +M } %R SO $N RS %D . . > %I N N ^ %N n +N ~ %S SI $O US %E / /O ? %J O O _ %O o +O DEL %T Character pairs /M and /N decode as a minus sign and period respectively. Character pairs /P through /Y decode as 0 through 9. Full ASCII On * Full ASCII Off Code 39 Code Page Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, scan the bar code below, select the code page with which the bar codes were created (see Code Page Mapping of Printed Bar Codes on page A-6), 7-9 and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly. Code 39 Code Page Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings > Interleaved 2 of 5 On/Off * On Off Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads Interleaved 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data. 7 - 10 When Check Digit is set to Validate and Transmit, the scanner only reads Interleaved 2 of 5 bar codes printed with a check digit, and will transmit this digit at the end of the scanned data. Default = No Check Digit. * No Check Digit Validate, but Don’t Transmit Validate and Transmit Interleaved 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length 7 - 11 NEC 2 of 5 < Default All NEC 2 of 5 Settings > NEC 2 of 5 On/Off * On Off Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads NEC 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data. When Check Digit is set to Validate and Transmit, the scanner only reads NEC 2 of 5 bar codes printed with a check digit, and will transmit this digit at the end of the scanned data. Default = No Check Digit. * No Check Digit Validate, but Don’t Transmit Validate and Transmit 7 - 12 NEC 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length 7 - 13 Code 93 < Default All Code 93 Settings > Code 93 On/Off * On Off Code 93 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 93 Append This function allows the scanner to append the data from several Code 93 bar codes together before transmitting them to the host computer. When this function is enabled, the scanner stores those Code 93 bar codes that start with a space (excluding the start and stop symbols), and does not immediately transmit the data. The scanner stores the data in the order in 7 - 14 which the bar codes are read, deleting the first space from each. The scanner transmits the appended data when it reads a Code 93 bar code that starts with a character other than a space. Default = Off. On * Off Code 93 Code Page Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, scan the bar code below, select the code page with which the bar codes were created (see Code Page Mapping of Printed Bar Codes on page A-6), and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly. Code 93 Code Page 7 - 15 Straight 2 of 5 Industrial (three-bar start/stop) Straight 2 of 5 Industrial On/Off On * Off Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length 7 - 16 Straight 2 of 5 IATA (two-bar start/stop) Straight 2 of 5 IATA On/Off On * Off Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length 7 - 17 Matrix 2 of 5 Matrix 2 of 5 On/Off On * Off Matrix 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length 7 - 18 Code 11 Code 11 On/Off On * Off Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes. Default = Two Check Digits. One Check Digit * Two Check Digits 7 - 19 Code 11 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 128 Code 128 On/Off * On Off ISBT 128 Concatenation In 1994 the International Society of Blood Transfusion (ISBT) ratified a standard for communicating critical blood information in a uniform manner. The use of ISBT formats requires a paid license. The ISBT 128 Application Specification describes 1) the critical data elements for labeling blood products, 2) the current recommendation to use Code 128 due to its high degree of security and its space-efficient design, 3) a variation of Code 128 7 - 20 that supports concatenation of neighboring symbols, and 4) the standard layout for bar codes on a blood product label. Use the bar codes below to turn concatenation on or off. Default =Off. On * Off Code 128 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 128 Append This function allows the scanner to append the data from several Code 128 bar codes together before transmitting them to the host computer. When the scanner encounters a Code 128 bar code with the append trigger character(s), it buffers Code 128 bar codes until it reads a Code 128 bar code that does not have the append trigger. The data is then transmitted in the order in which the bar codes were read (FIFO). Default = Off. On * Off 7 - 21 Code 128 Code Page Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, scan the bar code below, select the code page with which the bar codes were created (see Code Page Mapping of Printed Bar Codes on page A-6), and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly. Code 128 Code Page 7 - 22 GS1-128 GS1-128 On/Off * On Off GS1-128 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 1, Maximum Default = 80. Minimum Message Length Maximum Message Length 7 - 23 Telepen Telepen On/Off On * Off Telepen Output Using AIM Telepen Output, the scanner reads symbols with start/stop pattern 1 and decodes them as standard full ASCII (start/stop pattern 1). When Original Telepen Output is selected, the scanner reads symbols with start/stop pattern 1 and decodes them as compressed numeric with optional full ASCII (start/stop pattern 2). Default = AIM Telepen Output. * AIM Telepen Output Original Telepen Output 7 - 24 Telepen Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-60. Minimum Default = 1, Maximum Default = 60. Minimum Message Length Maximum Message Length UPC-A UPC-A On/Off * On Off UPC-A Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On Off 7 - 25 UPC-A Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On. * On Off UPC-A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-A data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off UPC-A Addenda Required When Required is scanned, the scanner will only read UPC-A bar codes that have addenda. You must then turn on a 2 or 5 digit addenda listed on page 7-26. Default = Not Required. Required * Not Required 7 - 26 UPC-A Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space. Default = On. * On Off UPC-A/EAN-13 with Extended Coupon Code Use the following codes to enable or disable UPC-A and EAN-13 with Extended Coupon Code. When left on the default setting (Off), the scanner treats Coupon Codes and Extended Coupon Codes as single bar codes. If you scan the Allow Concatenation code, when the scanner sees the coupon code and the extended coupon code in a single scan, it transmits both as separate symbologies. Otherwise, it transmits the first coupon code it reads. If you scan the Require Concatenation code, the scanner must see and read the coupon code and extended coupon code in a single read to transmit the data. No data is output unless both codes are read. Default = Off. * Off Allow Concatenation Require Concatenation 7 - 27 Coupon GS1 DataBar Output If you scan coupons that have both UPC and GS1 DataBar codes, you may wish to scan and output only the data from the GS1 DataBar code. Scan the GS1 Output On code below to scan and output only the GS1 DataBar code data. Default = GS1 Output Off. * GS1 Output Off GS1 Output On UPC-E0 UPC-E0 On/Off Most U.P.C. bar codes lead with the 0 number system. To read these codes, use the UPC-E0 On selection. If you need to read codes that lead with the 1 number system, use UPC-E1 (page 7-31). Default = On. * UPC-E0 On UPC-E0 Off 7 - 28 UPC-E0 Expand UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format. Default = Off. On * Off UPC-E0 Addenda Required When Required is scanned, the scanner will only read UPC-E bar codes that have addenda. Default = Not Required. Required * Not Required UPC-E0 Addenda Separator When this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned Off, there is no space. Default = On. * On Off 7 - 29 UPC-E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On Off UPC-E0 Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. To prevent transmission, scan Off. Default = On. * On Off UPC-E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-E data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off 7 - 30 UPC-E1 Most U.P.C. bar codes lead with the 0 number system. For these codes, use UPC-E0 (page 7-28). If you need to read codes that lead with the 1 number system, use the UPC-E1 On selection. Default = Off. UPC-E1 On * UPC-E1 Off EAN/JAN-13 EAN/JAN-13 On/Off * On Off EAN/JAN-13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On Off 7 - 31 EAN/JAN-13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-13 Addenda Required When Required is scanned, the scanner will only read EAN/JAN-13 bar codes that have addenda. Default = Not Required. Required * Not Required 7 - 32 EAN/JAN-13 Addenda Separator When this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned Off, there is no space. Default = On. * On Off Note: If you want to enable or disable EAN13 with Extended Coupon Code, refer to UPC-A/EAN-13 with Extended Coupon Code (page 7-27). ISBN Translate When On is scanned, EAN-13 Bookland symbols are translated into their equivalent ISBN number format. Default = Off. On * Off 7 - 33 EAN/JAN-8 EAN/JAN-8 On/Off * On Off EAN/JAN-8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On Off 7 - 34 EAN/JAN-8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-8 Addenda Required When Required is scanned, the scanner will only read EAN/JAN-8 bar codes that have addenda. Default = Not Required. Required * Not Required EAN/JAN-8 Addenda Separator When this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned Off, there is no space. Default = On. * On Off 7 - 35 MSI MSI On/Off On * Off MSI Check Character Different types of check characters are used with MSI bar codes. You can program the scanner to read MSI bar codes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit. When Check Character is set to Validate Type 10/11 and Transmit, the scanner will only read MSI bar codes printed with the specified type check character(s), and will transmit the character(s) at the end of the scanned data. 7 - 36 When Check Character is set to Validate Type 10/11, but Don’t Transmit, the unit will only read MSI bar codes printed with the specified type check character(s), but will not transmit the check character(s) with the scanned data. * Validate Type 10, but Don’t Transmit Validate Type 10 and Transmit Validate 2 Type 10 Characters, but Don’t Transmit Validate 2 Type 10 Characters and Transmit Validate Type 10 then Type 11 Character, but Don’t Transmit Validate Type 10 then Type 11 Character and Transmit Disable MSI Check Characters MSI Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length 7 - 37 GS1 DataBar Omnidirectional < Default All GS1 DataBar Omnidirectional Settings > GS1 DataBar Omnidirectional On/Off * On Off GS1 DataBar Limited < Default All GS1 DataBar Limited Settings > GS1 DataBar Limited On/Off * On Off 7 - 38 GS1 DataBar Expanded < Default All GS1 DataBar Expanded Settings > GS1 DataBar Expanded On/Off * On Off GS1 DataBar Expanded Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 4-74. Minimum Default = 4, Maximum Default = 74. Minimum Message Length Maximum Message Length 7 - 39 Trioptic Code Note: If you are going to scan Code 32 Pharmaceutical codes (page 7-8), Trioptic Code must be off. Trioptic Code is used for labeling magnetic storage media. On * Off Codablock A Codablock A On/Off On * Off 7 - 40 Codablock A Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-600. Minimum Default = 1, Maximum Default = 600. Minimum Message Length Maximum Message Length 7 - 41 Codablock F Codablock F On/Off On * Off Codablock F Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-2048. Minimum Default = 1, Maximum Default = 2048. Minimum Message Length Maximum Message Length 7 - 42 PDF417 < Default All PDF417 Settings > PDF417 On/Off * On Off PDF417 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750. Minimum Message Length Maximum Message Length 7 - 43 MicroPDF417 < Default All MicroPDF417 Settings > MicroPDF417 On/Off On * Off MicroPDF417 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-366. Minimum Default = 1, Maximum Default = 366. Minimum Message Length Maximum Message Length 7 - 44 GS1 Composite Codes Linear codes are combined with a unique 2D composite component to form a new class called GS1 Composite symbology. GS1 Composite symbologies allow for the co-existence of symbologies already in use. Default = Off. On * Off UPC/EAN Version Scan the UPC/EAN Version On bar code to decode GS1 Composite symbols that have a U.P.C. or an EAN linear component. (This does not affect GS1 Composite symbols with a GS1-128 or GS1 linear component.) Default = UPC/EAN Version Off. UPC/EAN Version On * UPC/EAN Version Off Note: If you scan coupons that have both UPC and GS1 DataBar codes, you may wish to scan and output only the data from the GS1 DataBar code. See Coupon GS1 DataBar Output (page 7-28) for further information. GS1 Composite Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-2435. Minimum Default = 1, Maximum Default = 2435. Minimum Message Length Maximum Message Length 7 - 45 GS1 Emulation The scanner can automatically format the output from any GS1 data carrier to emulate what would be encoded in an equivalent GS1-128 or GS1 DataBar symbol. GS1 data carriers include UPC-A and UPC-E, EAN-13 and EAN-8, ITF-14, GS1-128, and GS1-128 DataBar and GS1 Composites. (Any application that accepts GS1 data can be simplified since it only needs to recognize one data carrier type.) If GS1-128 Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8, EAN13) are expanded out to 16 digits. If the AIM ID is enabled, the value will be the GS1-128 AIM ID, ]C1 (see Symbology Chart on page A-1). If GS1 DataBar Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8, EAN13) are expanded out to 16 digits. If the AIM ID is enabled, the value will be the GS1-DataBar AIM ID, ]em (see Symbology Chart on page A-1). If GS1 Code Expansion Off is scanned, retail code expansion is disabled, and UPC-E expansion is controlled by the UPC-E0 Expand (page 7-29) setting. If the AIM ID is enabled, the value will be the GS1-128 AIM ID, ]C1 (see Symbology Chart on page A-1). If EAN8 to EAN13 Conversion is scanned, all EAN8 bar codes are converted to EAN13 format. Default = GS1 Emulation Off. GS1-128 Emulation GS1 DataBar Emulation GS1 Code Expansion Off EAN8 to EAN13 Conversion * GS1 Emulation Off 7 - 46 TCIF Linked Code 39 (TLC39) This code is a composite code since it has a Code 39 linear component and a MicroPDF417 stacked code component. All bar code readers are capable of reading the Code 39 linear component. The MicroPDF417 component can only be decoded if TLC39 On is selected. The linear component may be decoded as Code 39 even if TLC39 is off. Default = Off. On * Off QR Code < Default All QR Code Settings > QR Code On/Off This selection applies to both QR Code and Micro QR Code. * On Off 7 - 47 QR Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-7089. Minimum Default = 1, Maximum Default = 7089. Minimum Message Length Maximum Message Length QR Code Page QR Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, scan the bar code below, select the code page with which the bar codes were created (see Code Page Mapping of Printed Bar Codes on page A-6), and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly. QR Code Page 7 - 48 Data Matrix < Default All Data Matrix Settings > Data Matrix On/Off * On Off Data Matrix Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-3116. Minimum Default = 1, Maximum Default = 3116. Minimum Message Length Maximum Message Length Data Matrix Code Page Data Matrix Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, scan the bar code below, select the code page with which the bar codes were created (see Code Page Mapping of Printed Bar Codes on 7 - 49 page A-6), and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly. Data Matrix Code Page Low Density Data Matrix If you are reading low density Data Matrix codes (codes with little information), you can scan the Low Density Codes On bar code below. This setting improves scanner performance when reading these Data Matrix codes. Default = Low Density Codes Off. Low Density Codes On * Low Density Codes Off 7 - 50 MaxiCode < Default All MaxiCode Settings > MaxiCode On/Off On * Off MaxiCode Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-150. Minimum Default = 1, Maximum Default = 150. Minimum Message Length Maximum Message Length 7 - 51 Aztec Code < Default All Aztec Code Settings > Aztec Code On/Off * On Off Aztec Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-3832. Minimum Default = 1, Maximum Default = 3832. Minimum Message Length Maximum Message Length Aztec Append This function allows the scanner to append the data from several Aztec bar codes together before transmitting them to the host computer. When the scanner encounters an Aztec bar code with the append trigger charac- 7 - 52 ter(s), it buffers the number of Aztec bar codes determined by information encoded in those bar codes. Once the proper number of codes is reached, the data is output in the order specified in the bar codes. Default = Off. On * Off Aztec Code Page Aztec Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, scan the bar code below, select the code page with which the bar codes were created (see Code Page Mapping of Printed Bar Codes on page A-6), and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly. Aztec Code Page 7 - 53 Chinese Sensible (Han Xin) Code < Default All Han Xin Settings > Han Xin Code On/Off On * Off Han Xin Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-7833. Minimum Default = 1, Maximum Default = 7833. Minimum Message Length Maximum Message Length 7 - 54 Postal Codes - 2D The following lists the possible 2D postal codes, and 2D postal code combinations that are allowed. Only one 2D postal code selection can be active at a time. If you scan a second 2D postal code selection, the first selection is overwritten. Default = 2D Postal Codes Off. * 2D Postal Codes Off Single 2D Postal Codes: Australian Post On British Post On Canadian Post On Intelligent Mail Bar Code On Japanese Post On KIX Post On Planet Code On Also see Planet Code Check Digit, page 7-58. Postal-4i On 7 - 55 Postnet On Also see Postnet Check Digit, page 7-58. Postnet with B and B’ Fields On InfoMail On Combination 2D Postal Codes: InfoMail and British Post On Intelligent Mail Bar Code and Postnet with B and B’ Fields On Postnet and Postal-4i On Postnet and Intelligent Mail Bar Code On Postal-4i and Intelligent Mail Bar Code On Postal-4i and Postnet with B and B’ Fields On Planet Code and Postnet On Planet Code and Postnet with B and B’ Fields On 7 - 56 Planet Code and Postal-4i On Planet Code and Intelligent Mail Bar Code On Planet Code, Postnet, and Postal-4i On Planet Code, Postnet, and Intelligent Mail Bar Code On Planet Code, Postal-4i, and Intelligent Mail Bar Code On Postnet, Postal-4i, and Intelligent Mail Bar Code On Planet Code, Postal-4i, and Postnet with B and B’ Fields On Planet Code, Intelligent Mail Bar Code, and Postnet with B and B’ Fields On Postal-4i, Intelligent Mail Bar Code, and Postnet with B and B’ Fields On Planet Code, Postal-4i, Intelligent Mail Bar Code, and Postnet On Planet Code, Postal-4i, Intelligent Mail Bar Code, and Postnet with B and B’ Fields On 7 - 57 Planet Code Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of Planet Code data. Default = Don’t Transmit. Transmit Check Digit * Don’t Transmit Check Digit Postnet Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of Postnet data. Default = Don’t Transmit. Transmit Check Digit * Don’t Transmit Check Digit Australian Post Interpretation This option controls what interpretation is applied to customer fields in Australian 4-State symbols. Bar Output lists the bar patterns in “0123” format. Numeric N Table causes that field to be interpreted as numeric data using the N Table. Alphanumeric C Table causes the field to be interpreted as alphanumeric data using the C Table. Refer to the Australian Post Specification Tables. Combination C and N Tables causes the field to be interpreted using either the C or N Tables. 7 - 58 * Bar Output Numeric N Table Alphanumeric C Table Combination C and N Tables Postal Codes - Linear The following lists linear postal codes. Any combination of linear postal code selections can be active at a time. China Post (Hong Kong 2 of 5) 7 - 59 China Post (Hong Kong 2 of 5) On/Off On * Off China Post (Hong Kong 2 of 5) Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length 7 - 60 Korea Post Korea Post On * Off Korea Post Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length Korea Post Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data. Default = Don’t Transmit. Transmit Check Digit * Don’t Transmit Check Digit 7 - 61 7 - 62 8 Imaging Commands The scanner is like a digital camera in the way it captures, manipulates, and transfers images. The following commands allow you to alter the way the scanner performs these functions. Note: If you are using the scanner in a stand, you must set the In-Stand Sensor Mode to Off in order to take images (see In-Stand Sensor Mode on page 4-11). Single-Use Basis Imaging Commands with their modifiers send instructions to the scanner on a single-use basis, and take effect for a single image capture. Once that capture is complete, the scanner reverts to its imaging default settings. If you want to permanently change a setting, you must use the serial default commands (see Chapter 11). When the serial default command is used, that selection becomes the new, permanent setting for the scanner. Command Syntax Multiple modifiers and commands can be issued within one sequence. If additional modifiers are to be applied to the same command, just add the modifiers to that command. For example, to add 2 modifiers to the Image Snap command, such as setting the Imaging Style to 1P and the Wait for Trigger to 1T, you would enter IMGSNP1P1T. Note: After processing an image capture command (IMGSNP or IMGBOX), you must follow it with an IMGSHP command if you want to see it on your terminal. To add a command to a sequence, each new command is separated with a semicolon. For example, to add the Image Ship command to the above sequence, you would enter IMGSNP1P1T;IMGSHP. The imaging commands are: Image Snap - IMGSNP (page 8-2) Image Ship - IMGSHP (page 8-5) Intelligent Signature Capture - IMGBOX (page 8-14) The modifiers for each of these commands follow the command description. Note: The images included with each command description are examples only. The results you achieve may be different from those included in this manual. The quality of the output you receive will vary depending on lighting, quality of the initial image/object being captured, and distance of the scanner from the image/object. To achieve a high quality image, it is recommended that you position your scanner 4-6" (10.2-15.2 cm) away from the image/object you are capturing. 8-1 Step 1 - Take a Picture Using IMGSNP Image Snap - IMGSNP An image is taken whenever the hardware button is pressed, or when the Image Snap (IMGSNP) command is processed. The image snap command has many different modifiers that can be used to change the look of the image in memory. Modifiers always begin with numbers and end with a letter (case insensitive). Any number of modifiers may be appended to the IMGSNP command. For example, you can use the following command to snap an image, increase the gain, and have the beeper sound once the snap is complete: IMGSNP2G1B IMGSNP Modifiers P - Imaging Style This sets the Image Snap style. 0P Decoding Style. This processing allows a few frames to be taken until the exposure parameters are met. The last frame is then available for further use. 1P Photo Style (default). This mimics a simple digital camera, and results in a visually optimized image. 2P Manual Style. This is an advanced style that should only be used by an experienced user. It allows you the most freedom to set up the scanner, and has no auto-exposure. B - Beeper Causes a beep to sound after an image is snapped. 0B No beep (default) 1B Sounds a beep when the image is captured. T - Wait for Trigger Waits for a hardware button push before taking the image. This is only available when using Photo Style (1P). 0T Takes image immediately (default) 1T Waits for a button push, then takes the image L - LED State Determines if the LEDs should be on or off, and when. Ambient illumination (0L) is preferred for taking pictures of color documents, such as ID cards, especially when the scanner is in a stand. LED illumination (1L) is preferred when the scanner is handheld. LED State is not available when using Decoding Style (0P). 0L LEDs off (default) 1L LEDs on 8-2 E - Exposure Exposure is used in Manual Style only (2P), and allows you to set the exposure time. This is similar to setting a shutter speed on a camera. The exposure time determines how long the scanner takes to record an image. On a bright day, exposure times can be very short because plenty of light is available to help record an image. At nighttime, exposure time can increase dramatically due to the near absence of light. Units are 127 microseconds. (Default = 7874) nE Range: 1 - 7874 Example of Exposure at 7874E with fluorescent lighting: Example of Exposure at 100E with fluorescent lighting: G - Gain Gain is used in Manual Style only (2P). Like a volume control, the gain modifier boosts the signal and multiplies the pixel value. As you increase the gain, the noise in an image is also amplified. 1G No gain (default) 2G Medium gain 4G Heavy gain 8G Maximum gain Example of Gain at Example of Gain at 1G: 4G: Example of Gain at 8G: 8-3 W - Target White Value Sets the target for the median grayscale value in the captured image. For capturing close-up images of high contrast documents, a lower setting, such as 75, is recommended. Higher settings result in longer exposure times and brighter images, but if the setting is too high, the image may be overexposed. Target White Value is only available when using Photo Style (1P). (Default = 125) nW Range: 0 - 255 Example of White Value at 75W: Example of White Value at 125W: Example of White Value at 200W: D - Delta for Acceptance This sets the allowable range for the white value setting (see W - Target White Value). Delta is only available when using Photo Style (1P). (Default = 25) nD Range: 0 - 255 U - Update Tries This sets the maximum number of frames the scanner should take to reach the D - Delta for Acceptance. Update Tries is only available when using Photo Style (1P). (Default = 6) nU Range: 0 - 10 % - Target Set Point Percentage Sets the target point for the light and dark values in the captured image. A setting of 75% means 75% of the pixels are at or below the target white value, and 25% of the pixels are above the target white value. Altering this setting from the default is not recommended under normal circumstances. To alter grayscale values, W - Target White Value should be used. (Default = 50) n% Range: 1 - 99 Example of Target Example of Target Set Point Set Point Percentage at 97%: Percentage at 50%: 8-4 Example of Target Set Point Percentage at 40%: Step 2 - Ship a Picture Using IMGSHP Image Ship - IMGSHP An image is taken whenever the button is pressed, or when the Image Snap (IMGSNP) command is processed. The last image is always stored in memory. You can “ship” the image by using the IMGSHP command. The image ship commands have many different modifiers that can be used to change the look of the image output. Modifiers affect the image that is transmitted, but do not affect the image in memory. Modifiers always begin with a number and end with a letter (case insensitive). Any number of modifiers may be appended to the IMGSHP command. For example, you can use the following command to snap and ship a bitmap image with gamma correction and document image filtering: IMGSNP;IMGSHP8F75K26U IMGSHP Modifiers A - Infinity Filter Enhances pictures taken from very long distances (greater than 10 feet or 3m). The Infinity Filter should not be used with IMGSHP Modifiers (page 85). 0A Infinity filter off (default) 1A Infinity filter on Example of Infinity Filter off (0A) from approximately 12 feet (3.66m) away: Example of Infinity Filter on (1A) from approximately 12 feet (3.66m) away: 8-5 C - Compensation Flattens the image to account for variations in illumination across the image. 0C Compensation disabled (default) 1C Compensation enabled Example of Compensation at 0C: Example of Compensation at 1C: D - Pixel Depth Indicates the number of bits per pixel in the transmitted image (KIM or BMP format only). 8D 8 bits per pixel, grayscale image (default) 1D 1 bit per pixel, black and white image 8-6 E - Edge Sharpen An edge sharpen filter cleans up the edges of an image, making it look cleaner and sharper. While edge sharpening does make the image look cleaner, it also removes some fine detail from the original image. The strength of the edge sharpen filter can be entered from 1 to 24. Entering a 23E gives the sharpest edges, but also increases noise in the image. 0E Don’t sharpen image (default) 14E Apply edge sharpen for typical image ne Apply edge sharpen using strength n (n = 1-24) Example of Edge Sharpen at 0E: Example of Edge Sharpen at 24E: F - File Format Indicates the desired format for the image. 0F KIM format 1F TIFF binary 2F TIFF binary group 4, compressed 3F TIFF grayscale 4F Uncompressed binary (upper left to lower right, 1 pixel/bit, 0 padded end of line) 5F Uncompressed grayscale (upper left to lower right, bitmap format) 6F JPEG image (default) 8F BMP format (lower right to upper left, uncompressed) 8-7 H - Histogram Stretch Increases the contrast of the transmitted image. Not available with some image formats. 0H No stretch (default) 1H Histogram stretch Example of Histogram Stretch at 0H: Example of Histogram Stretch at 1H: I - Invert Image Invert image is used to rotate the image around the X or Y axis. 1ix Invert around the X axis (flips picture upside down) 1iy Invert around the Y axis (flips picture left to right) Example of image not inverted: 8-8 Example of image with Invert Image set to 1ix: Example of image with Invert Image set to 1iy: IF- Noise Reduction Used to reduce the salt and pepper noise in an image. 0if No salt and pepper noise reduction (default) 1if Salt and pepper noise reduction Example of Noise Reduction Off (0if): Example of Noise Reduction On (1if): IR - Image Rotate 0ir Image as snapped (rightside up) (default) 1ir Rotate image 90 degrees to the right 2ir Rotate image 180 degrees (upside down) 3ir Rotate image 90 degrees to the left Example of Image Rotate set to 0ir: Example of Image Rotate set to 2ir: Example of Image Rotate set to 1ir: Example of Image Rotate set to 3ir: 8-9 J - JPEG Image Quality Sets the desired quality when the JPEG image format is selected. Higher numbers result in higher quality, but larger files. Smaller numbers result in greater amounts of lossy compression, faster transmission times, lower quality, but smaller files. (Default = 50) nJ Image is compressed as much as possible while preserving quality factor of n (n = 0 - 100) 0J worst quality (smallest file) 100J best quality (largest file) K - Gamma Correction Gamma measures the brightness of midtone values produced by the image. You can brighten or darken an image using gamma correction. A higher gamma correction yields an overall brighter image. The lower the setting, the darker the image. The optimal setting for text images is 50K. 0K Gamma correction off (default) 50K Apply gamma correction for brightening typical document image nK Apply gamma correction factor n (n = 0-1,000) Example of Gamma Correction set to 0K: Example of Gamma Correction set to 50K: Example of Gamma Correction set to 255K: L, R, T, B, M - Image Cropping Note: Image Cropping should not be used with IMGSHP Modifiers (see page 8-5). Ships a window of the image by specifying the left, right, top, and bottom pixel coordinates. Device columns are numbered 0 through 1279, and device rows are numbered 0 through 959. nL The left edge of the shipped image corresponds to column n of the image in memory. Range: 000 - 640. (Default = 0) nR The right edge of the shipped image corresponds to column n - 1 of the image in memory. Range: 000 - 640. (Default = all columns) nT The top edge of the shipped image corresponds to row n of the image in memory. Range: 000 - 480. (Default = 0) 8 - 10 nB The bottom edge of the shipped image corresponds to row n - 1 of the image in memory. Range: 000 - 480. (Default = all rows) Uncropped Image: Example of Image Crop set to 300R: Example of Image Crop set to 200B: Example of Image Crop set to 300L: Example of Image Crop set to 200T: Alternately, specify the number of pixels to cut from the outside margin of the image; thus only the center pixels are transmitted. nM Margin: cut n columns from the left, n + 1 columns from the right, n rows from the top, and n + 1 rows from the bottom of the image. Ship the remaining center pixels. Range: 0 - 238. (Default = 0, or full image) Example of Image Crop set to 238M: P - Protocol Used for shipping an image. Protocol covers two features of the image data being sent to the host. It addresses the protocol used to send the data (Hmodem, which is an Xmodem 1K variant that has additional header information), and the format of the image data that is sent. 0P None (raw data) 2P None (default for USB) 3P Hmodem compressed (default for RS232) 4P Hmodem S - Pixel Ship Pixel Ship sizes an image in proportion to its original size. It decimates the image by shipping only certain, regularly spaced pixels. For example, 4S would transmit every fourth pixel from every fourth line. The smaller number of pixels shipped, the smaller the image, however, after a certain point the image becomes unusable. 8 - 11 1S ship every pixel (default) 2S ship every 2nd pixel, both horizontally and vertically 3S ship every 3rd pixel, both horizontally and vertically Example of Pixel Ship set to 1S: Example of Pixel Ship set to 2S: Example of Pixel Ship set to 3S: U - Document Image Filter Allows you to input parameters to sharpen the edges and smooth the area between the edges of text in an image. This filter should be used with gamma correction (see page 8-10), with the scanner in a stand, and the image captured using the command: IMGSNP1P0L168W90%32D This filter typically provides better JPEG compression than the standard E Edge Sharpen command (see page 8-13). This filter also works well when shipping pure black and white images (1 bit per pixel). The optimal setting is 26U. 0U Document image filter off (default) 26U Apply document image filter for typical document image nU Apply document image filter using grayscale threshold n. Use lower numbers when the image contrast is lower. 1U will have a similar effect to setting E - Edge Sharpen (page 8-7) to 22e. Range: 0-255. Example of Document Image Filter set to 0U: 8 - 12 Example of Document Image Filter set to 26U: V - Blur Image Smooths transitions by averaging the pixels next to the hard edges of defined lines and shaded areas in an image. 0V Don’t blur (default) 1V Blur Example of Blur Image Off (0V): Example of Blur Image On (1V): W - Histogram Ship A histogram gives a quick picture of the tonal range of an image, or key type. A low-key image has detail concentrated in the shadows; a high-key image has detail concentrated in the highlights; and an average-key image has detail concentrated in the midtones. This modifier ships the histogram for an image. 0W Don’t ship histogram (default) 1W Ship histogram Image used for histogram: Histogram of image at left: 8 - 13 Image Size Compatibility If you have applications that expect an image ship to return exactly 640x480 pixels, scan the Force VGA Resolution bar code. Default = Native Resolution Force VGA Resolution * Native Resolution Intelligent Signature Capture - IMGBOX IMGBOX allows you to configure the size and location of a signature capture area relative to its proximity to a bar code. This allows you to tailor a signature capture area to a specific form. In order to use IMGBOX, you need a set form where the signature box location is in a known location relative to a bar code. You can input the overall size of the signature area, as well as specify how far the signature area is from the bar code, vertically and horizontally. You can also set the resolution and file format for the final output of the signature capture image. Note: IMGBOX commands can only be triggered by one of the following types of bar codes: PDF417, Code 39, Code 128, Aztec, Codabar, and Interleaved 2 of 5. Once one of these symbologies has been read, the image is retained for a possible IMGBOX command. Signature Capture Optimize If you will be using your scanner to capture signatures frequently, you should optimize it for this purpose. However, the speed of scanning bar codes may be slowed when this mode is enabled. Default = Off. Optimize On * Optimize Off 8 - 14 The following IMGBOX example was executed and viewed using QuickView software. This software is available at www.honeywellaidc.com. Click on Software Downloads. Select 4600r from the Products list, then select QuickView Software Utility. Below is an example of a signature capture application. In this example, the aimer is centered over the signature capture area and the trigger is pressed. A single beep is emitted, indicating that the scanner has read a Code 128 bar code and the data has been transferred to the host. An IMGBOX command may now be sent from the host to specify the coordinates of the signature capture area below that code, and indicating that only that area containing the signature should be transferred as an image to the host. To see this example, align the aimer with the signature area (not with the bar code), then press the trigger. Send the following IMGBOX command string after the button push: Example: IMGBOX245w37h55y. Note: Case is not important in the command string. It is used here only for clarity. The following image is captured: The IMGBOX commands have many different modifiers that can be used to change the size and appearance of the signature image output by the scanner. Modifiers affect the image that is transmitted, but do not affect the image in memory. Modifiers always begin with a number and end with a letter (case insensitive). Any number of modifiers may be appended to the IMGBOX command. Note: The IMGBOX command will return a NAK unless a window size (width and height) are specified. See H - Height of Signature Capture Area (page 8-17) and W - Width of Signature Capture Area (page 8-18). IMGBOX Modifiers A - Output Image Width 8 - 15 This option is used to size the image horizontally. If using this option, set the resolution (R) to zero. Example of Image Width set to 200A: Example of Image Width set to 600A: B - Output Image Height This option is used to size the image vertically. If using this option, set the resolution (R) to zero. Example of Image Height set to 50B: Example of Image Height set to 100B: D - Pixel Depth This indicates the number of bits per pixel in the transmitted image, which defines whether it will be grayscale or black and white. 8D 8 bits per pixel, grayscale image (default) 1D 1 bit per pixel, black and white image F - File Format This option indicates the type of file format in which to save the image. 0F KIM format 1F TIFF binary 2F TIFF binary group 4, compressed 3F TIFF grayscale 4F Uncompressed Binary 5F Uncompressed grayscale 6F JPEG image (default) 7F Outlined image 8 - 16 8F BMP format H - Height of Signature Capture Area The height of the signature capture area must be measured in inches divided by .01. In the example, the height of the area to be captured is 3/8 inch, resulting in a value of H = .375/0.01 = 37.5. Example: IMGBOX245w37h55y. K - Gamma Correction Gamma measures the brightness of midtone values produced by the image. You can brighten or darken an image using gamma correction. A higher gamma correction yields an overall brighter image. The lower the setting, the darker the image. The optimal setting for text images is 50K. 0K Gamma correction off (default) 50K Apply gamma correction for brightening typical document image nK Apply gamma correction factor n (n = 1-255) Example of Gamma Correction set to 0K: Example of Gamma Correction set to 50K: Example of Gamma Correction set to 255K: R - Resolution of Signature Capture Area The resolution is the number of pixels that the scanner outputs per each minimum bar width. The higher the value for R, the higher the quality of the image, but also the larger the file size. Values begin at 1000. The scanner automatically inserts a decimal point between the first and second digit. 8 - 17 For example, use 2500 to specify a resolution of 2.5. Set to zero when using the A and B modifiers (see A - Output Image Width and B - Output Image Height on page 8-16). Example of Resolution set to 0R: Example of Resolution set to 1000R: Example of Resolution set to 2000R: S - Bar Code Aspect Ratio All dimensions used in IMGBOX are measured as multiples of the minimum element size of the bar code. The bar code aspect ratio allows you to set the ratio of the bar code height to the narrow element width. In the example, the narrow element width is .010 inches and the bar code height is 0.400 inches, resulting in a value of S = 0.4/0.01 = 40. W - Width of Signature Capture Area The width of the signature capture area must be measured in inches divided by .01. In the example, the width of the area to be captured is 2.4 inches, resulting in a value of W = 2.4/0.01 = 240. (A value of 245 was used in the example to accommodate a slightly wider image area.) Example: IMGBOX245w37h55y. X - Horizontal Bar Code Offset The horizontal bar code offset allows you to offset the horizontal center of the signature capture area. Positive values move the horizontal center to the right and negative values to the left. Measurements are in multiples of the minimum bar width. Example of Horizontal Offset set to 75X: Example of Horizontal Offset set to -75X: 8 - 18 Y - Vertical Bar Code Offset The vertical bar code offset allows you to offset the vertical center of the signature capture area. Negative numbers indicate that the signature capture is above the bar code, and positive numbers indicate that the area is below the bar code. Measurements are in multiples of the minimum bar width. Example of Vertical Offset set to -7Y: Example of Vertical Offset set to 65Y: RF Default Imaging Device The scanner supports imaging command processing (IMGSHP, IMGSNP, IMGBOX) so that EZConfig-Scanning (see page 10-3) and other applications are able to perform imaging functions as if they were communicating directly with a scanner. To accomplish this, the scanner uses a menu command called RF_DID (RF Default Imaging Device). RF_DID is the name of the scanner (BT_NAM) that is to receive imaging commands. The default for RF_DID is “*”indicating that imaging commands are to be sent to all associated scanners. Change this setting to RF_DIDscanner_name to ensure that they are sent to a particular scanner. Refer to "Paging" on page 3-9 to generate a report containing the port, work group, scanner name, and address for each scanner. Refer to "Scanner Name" on page 3-22 set a unique name for each scanner. 8 - 19 8 - 20 9 Interface Keys Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the scanner. Refer to page 2-19 enable Control + ASCII mode. Function Code NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US HEX/ASCII Value 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Full ASCII “CTRL” + @ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _ 9-1 The last five characters in the Full ASCII “CTRL”+ column ( [ \ ] 6 - ), apply to US only. The following chart indicates the equivalents of these five characters for different countries. Country United States Codes [ \ ] 6 - Belgium [ < ] 6 - Scandinavia 8 < 9 6 - France ^ 8 $ 6 = à + 6 - Germany Italy \ + 6 - Switzerland < .. 6 - United Kingdom [ ¢ ] 6 - Denmark 8 \ 9 6 - Norway 8 \ 9 6 - Spain [ \ ] 6 - 9-2 Supported Interface Keys ASCII HEX IBM AT/XT and PS/2 Compatibles, WYSE PC/AT Supported Keys NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Reserved Enter (KP) Cap Lock ALT make ALT break CTRL make CTRL break CR/Enter Reserved Tab Reserved Tab Delete CR/Enter Insert Escape F11 Home Print Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 IBM XTs and Compatibles Supported Keys IBM, DDC, Memorex Telex, Harris* Supported Keys Reserved CR/Enter Caps Lock Reserved Reserved Reserved Reserved CR/Enter Reserved Tab Reserved Tab Delete CR/Enter Insert Escape Reserved Home Print Back Space Back Tab Reserved F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 Reserved Enter F11 F12 F13 F14 F15 New Line F16 F17 F18 Tab/Field Forward Delete Field Exit/New Line Insert F19 Error Reset Home F20 Back Space Backfield/Back Tab F21 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 9-3 ASCII HEX IBM AT/XT and PS/2 Compatibles, WYSE PC/AT Supported Keys IBM XTs and Compatibles Supported Keys * IBM 3191/92, 3471/72, 3196/97, 3476/77, Telex (all models) 9-4 IBM, DDC, Memorex Telex, Harris* Supported Keys Supported Interface Keys ASCII NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US HEX IBM, Memorex Telex (102)* Supported Keys Memorex Telex (88)** Supported Keys 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Reserved Enter F11 F12 F13 F14 F15 New Line F16 F17 F18 Tab/Field Forward Delete Field Exit Insert Clear Error Reset Home Print Back Space Back Tab F19 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 Reserved Enter PF10 PF11 PF12 Reserved Reserved New Line Field Forward Field Forward Reserved Field Forward Delete New Line Insert Erase Error Reset Reserved Print Back Space Back Field Reserved PF1 PF2 PF3 PF4 PF5 PF6 PF7 PF8 PF9 Home * IBM 3196/97, 3476/77, 3191/92, 3471/72, Memorex Telex (all models) with 102 key keyboards ** Memorex Telex with 88 key keyboards 9-5 Supported Interface Keys ASCII HEX Esprit 200, 400 ANSI Supported Keys NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab N/A New Line N/A Escape F11 Insert F13 Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 9-6 Esprit 200, 400 ASCII Supported Keys Esprit 200, 400 PC Supported Keys Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab N/A New Line N/A Escape F11 Insert F13 Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab Delete New Line Insert Escape F11 Home Print Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 Supported Interface Keys ASCII HEX Apple Mac/iMac Supported Keys NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US DEL 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 7F Reserved Enter/Numpad Enter CAPS ALT make ALT break CNTRL make CNTRL break RETURN APPLE make TAB APPLE break TAB Del RETURN Ins Help ESC F11 Home Prnt Scrn BACKSPACE LSHIFT TAB F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 BACKSPACE 9-7 9-8 10 Utilities To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Chart, beginning on page A-1) for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs a Code I.D. prefix for all symbologies. This is a temporary setting that will be removed when the unit is power cycled. Add Code I.D. Prefix to All Symbologies (Temporary) Show Decoder Revision Scan the bar code below to output the decoder revision. Show Decoder Revision Show Scan Driver Revision Scan the bar code below to output the scan driver revision. The scan driver controls image capture. Show Scan Driver Revision Show Software Revision Scan the bar code below to output the current software revision, unit serial number, and other product information for both the scanner and base. Show Revision 10 - 1 Show Data Format Scan the bar code below to show current data format settings. DFMBK3?. Data Format Settings Test Menu When you scan the Test Menu On code, then scan a programming code in this manual, the scanner displays the content of a programming code. The programming function will still occur, but in addition, the content of that programming code is output to the terminal. Note: This feature should not be used during normal scanner operation. On * Off TotalFreedom TotalFreedom is an open system architecture that makes it possible for you create applications that reside on your scanner. Decoding apps and Data Formatting apps can be created using TotalFreedom. For further information about TotalFreedom, go to our website at www.honeywellaidc.com. 10 - 2 Application Plug-Ins (Apps) Any apps that you are using can be turned off or on by scanning the following bar codes. Apps are stored in groups: Decoding, and Formatting. You can enable and disable these groups of apps by scanning that group’s On or Off bar code below. You can also scan the List Apps bar code to output a list of all your apps. * Decoding Apps On Decoding Apps Off * Formatting Apps On Formatting Apps Off List Apps Note: You must reset your device in order for the apps setting to take effect. EZConfig Introduction EZConfig provides a wide range of PC-based programming functions that can be performed on a scanner connected to your PC's COM port. EZConfig allows you to download upgrades to the scanner's firmware, change programmed parameters, and create and print programming bar codes. Using EZConfig, you can even save/open the programming parameters for a scanner. This saved file can be e-mailed or, if required, you can create a single bar code that contains all the customized programming parameters and mail or fax that bar code to any location. Users in other locations can scan the bar code to load in the customized programming. To communicate with a scanner, EZConfig requires that the PC have at least one available serial communication port, or a serial port emulation using a physical USB port. If you are using the serial port and RS232 cable, an external power supply is required. When using a USB serial port emulation, only a USB cable is required. EZConfig Operations The EZConfig software performs the following operations: 10 - 3 Scan Data Scan Data allows you to scan bar codes and display the bar code data in a window. Scan Data lets you send serial commands to the scanner and receive scanner response that can be seen in the Scan Data window. The data displayed in the Scan Data window can either be saved in a file or printed. Configure Configure displays the programming and configuration data of the scanner. The scanner's programming and configuration data is grouped into different categories. Each category is displayed as a tree item under the "Configure" tree node in the application explorer. When one of these tree nodes is clicked, the right-hand side is loaded with the parameters' form belonging to that particular category. The "Configure" tree option has all the programming and configuration parameters specified for a scanner. You can set or modify these parameters as required. You can later write the modified settings to the scanner, or save them to a dcf file. Imaging Imaging provides all the image-related functions that a 2D Scanner can perform. You can capture an image using the current settings, and the image will be displayed in an image window. Images captured from the scanner can be saved to files in different image formats. You can modify the image settings and save the image settings to an INI file, which can be loaded later to capture new images. Imaging also lets you preview the images continuously captured by the scanner. Installing EZConfig from the Web Note: EZConfig requires .NET software. If .NET is not installed on your PC, you will be prompted to install it during the EZConfig installation. 1. Access the Honeywell web site at www.honeywellaidc.com 2. Click on the Resources tab. Select Software. 3. Click on the dropdown for Select Product Number. Click on 1900 or 1902. 4. Click on the listing for EZConfig. 5. When prompted, select Save File, and save the files to the c:\windows\temp directory. 6. Once you have finished downloading the file, exit the web site. 7. Using Explorer, go to the c:\windows\temp file. 8. Double click on the Setup.exe file. Follow the screen prompts to install the EZConfig program. 10 - 4 9. If you’ve selected the defaults during installation, you can click on Start Menu-All Programs-Honeywell-EZConfig. 10 - 5 10 - 6 11 Serial Programming Commands The serial programming commands can be used in place of the programming bar codes. Both the serial commands and the programming bar codes will program the scanner. For complete descriptions and examples of each serial programming command, refer to the corresponding programming bar code in this manual. The device must be set to an RS232 interface (see page 2-2). The following commands can be sent via a PC COM port using terminal emulation software. Conventions The following conventions are used for menu and query command descriptions: parameter A label representing the actual value you should send as part of a command. An optional part of a command. [option] {Data} Alternatives in a command. bold Names of menus, menu commands, buttons, dialog boxes, and windows that appear on the screen. Menu Command Syntax Menu commands have the following syntax (spaces have been used for clarity only): Prefix [:Name:] Tag SubTag {Data} [, SubTag {Data}] [; Tag SubTag {Data}] […] Storage Prefix Three ASCII characters: SYN M CR (ASCII 22,77,13). :Name: To send information to the scanner (with the base connected to host), use :Xenon: The default factory setting for a Xenon scanner is Xenon scanner. This setting is changed by using the BT_NAM command, which accepts alphanumeric values. If the name is not known, a wildcard (*) can be used :*:. Note: Since the base stores all work group settings and transfers to them to scanner once they are linked, changes are typically done to the base and not to the scanner. Tag A 3 character case-insensitive field that identifies the desired menu command group. For example, all RS232 configuration settings are identified with a Tag of 232. SubTag A 3 character case-insensitive field that identifies the desired menu command within the tag group. For example, the SubTag for the RS232 baud rate is BAD. Data The new value for a menu setting, identified by the Tag and SubTag. 11 - 1 Storage A single character that specifies the storage table to which the command is applied. An exclamation point (!) performs the command’s operation on the device’s volatile menu configuration table. A period (.) performs the command’s operation on the device’s non-volatile menu configuration table. Use the non-volatile table only for semi-permanent changes you want saved through a power cycle. Query Commands Several special characters can be used to query the device about its settings. ^ ? * What is the default value for the setting(s). What is the device’s current value for the setting(s). What is the range of possible values for the setting(s). (The device’s response uses a dash (-) to indicate a continuous range of values. A pipe (|) separates items in a list of non-continuous values.) :Name: Field Usage (Optional) This command returns the query information from the scanner. Tag Field Usage When a query is used in place of a Tag field, the query applies to the entire set of commands available for the particular storage table indicated by the Storage field of the command. In this case, the SubTag and Data fields should not be used because they are ignored by the device. SubTag Field Usage When a query is used in place of a SubTag field, the query applies only to the subset of commands available that match the Tag field. In this case, the Data field should not be used because it is ignored by the device. Data Field Usage When a query is used in place of the Data field, the query applies only to the specific command identified by the Tag and SubTag fields. Concatenation of Multiple Commands Multiple commands can be issued within one Prefix/Storage sequence. Only the Tag, SubTag, and Data fields must be repeated for each command in the sequence. If additional commands are to be applied to the same Tag, then the new command sequence is separated with a comma (,) and only the SubTag and Data fields of the additional command are issued. If the additional command requires a different Tag field, the command is separated from previous commands by a semicolon (;). 11 - 2 Responses The device responds to serial commands with one of three responses: ACK Indicates a good command which has been processed. ENQ Indicates an invalid Tag or SubTag command. NAK Indicates the command was good, but the Data field entry was out of the allowable range for this Tag and SubTag combination, e.g., an entry for a minimum message length of 100 when the field will only accept 2 characters. When responding, the device echoes back the command sequence with the status character inserted directly before each of the punctuation marks (the period, exclamation point, comma, or semicolon) in the command. Examples of Query Commands In the following examples, a bracketed notation [ ] depicts a non-displayable response. Example: What is the range of possible values for Codabar Coding Enable? Enter: cbrena*. Response: CBRENA0-1[ACK] This response indicates that Codabar Coding Enable (CBRENA) has a range of values from 0 to 1 (off and on). Example: What is the default value for Codabar Coding Enable? Enter: cbrena^. Response: CBRENA1[ACK] This response indicates that the default setting for Codabar Coding Enable (CBRENA) is 1, or on. Example: What is the device’s current setting for Codabar Coding Enable? Enter: cbrena?. Response: CBRENA1[ACK] This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on. Example: What are the device’s settings for all Codabar selections? Enter: cbr?. Response: CBRENA1[ACK], SSX0[ACK], CK20[ACK], CCT1[ACK], MIN2[ACK], 11 - 3 MAX60[ACK], DFT[ACK]. This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on; the Start/Stop Character (SSX) is set to 0, or Don’t Transmit; the Check Character (CK2) is set to 0, or Not Required; concatenation (CCT) is set to 1, or Enabled; the Minimum Message Length (MIN) is set to 2 characters; the Maximum Message Length (MAX) is set to 60 characters; and the Default setting (DFT) has no value. Trigger Commands You can activate and deactivate the scanner with serial trigger commands. First, the scanner must be put in Manual Trigger Mode by scanning a Manual Trigger Mode bar code (page 4-6), or by sending a serial menu command for triggering (page 4-7). Once the scanner is in serial trigger mode, the trigger is activated and deactivated by sending the following commands: Activate: SYN T CR Deactivate: SYN U CR The scanner scans until a bar code has been read, until the deactivate command is sent, or until the serial time-out has been reached (see "Read TimeOut" on page 4-7 for a description, and the serial command on page 11-18). Resetting the Custom Defaults If you want the custom default settings restored to your scanner, scan the Activate Custom Defaults bar code below. This resets the scanner to the custom default settings. If there are no custom defaults, it will reset the scanner to the factory default settings. Any settings that have not been specified through the custom defaults will be defaulted to the factory default settings. Activate Custom Defaults Note: If using a cordless system, scanning this bar code also causes both the scanner and the base or Access Point to perform a reset and become unlinked. The scanner must be placed in its base to re-establish the link. If using an Access Point, the linking bar code must be scanned. See Cordless System Operation beginning on page 3-1 for additional information. The charts on the following pages list the factory default settings for each of the commands (indicated by an asterisk (*) on the programming pages). 11 - 4 Menu Commands Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Product Default Settings Setting Custom Defaults Set Custom Defaults MNUCDF 1-9 Save Custom Defaults DEFALT 1-9 Resetting the Custom Defaults Activate Custom Defaults DEFALT 1-10 Resetting the Factory Defaults Remove Custom Defaults DEFOVR 1-10 Activate Defaults DEFALT 1-10 Resetting the Factory Defaults - cordless scanners Factory Default Settings: All Application Groups PAPDFT& 3-25 Resetting the Custom Defaults cordless scanners Custom Default Settings: All Application Groups PAPDFT 3-26 Keyboard Wedge: IBM PC AT and Compatibles with CR suffix PAP_AT 2-1 Laptop Direct Connect with CR suffix PAPLTD 2-1 RS232 Serial Port PAP232 2-2 Programming the Interface Plug and Play Codes 11 - 5 Selection Plug and Play Codes: RS485 Plug and Play Codes: IBM SurePos Plug and Play Codes: USB 11 - 6 Setting Serial Command # Indicates a numeric entry Page IBM Port 5B Interface PAPP5B 2-2 IBM Port 9B HHBCR-1 Interface PAP9B1 2-2 IBM Port 17 Interface PAPP17 2-2 IBM Port 9B HHBCR-2 Interface PAP9B2 2-2 RS485 Packet Mode On RTLPDF1 2-3 RS485 Packet Mode Off RTLPDF0 2-3 RS485 Packet Length (20-256) RTLMPS 2-3 USB IBM SurePos Handheld PAPSPH 2-4 USB IBM SurePos Tabletop PAPSPT 2-4 USB Keyboard (PC) PAP124 2-4 USB Keyboard (Mac) PAP125 2-4 USB Japanese Keyboard (PC) TRMUSB134 2-4 USB HID PAP131 2-5 USB Serial TRMUSB130 2-5 CTS/RTS Emulation On USBCTS1 2-5 CTS/RTS Emulation Off* USBCTS0 2-5 ACK/NAK Mode On USBACK1 2-6 ACK/NAK Mode Off* USBACK0 2-6 * Indicates default Selection Plug and Play Codes Program Keyboard Country Setting Serial Command # Indicates a numeric entry Page Verifone Ruby Terminal PAPRBY 2-6 Gilbarco Terminal PAPGLB 2-7 Honeywell Bioptic Aux Port PAPBIO 2-7 Datalogic Magellan Bioptic Aux Port PAPMAG 2-7 NCR Bioptic Aux Port PAPNCR 2-8 Wincor Nixdorf Terminal PAPWNX 2-8 Wincor Nixdorf Beetle PAPBTL 2-9 *U.S.A. KBDCTY0 2-10 Albania KBDCTY35 2-10 Azeri (Cyrillic) KBDCTY81 2-10 Azeri (Latin) KBDCTY80 2-10 Belarus KBDCTY82 2-10 Belgium KBDCTY1 2-10 Bosnia KBDCTY33 2-10 Brazil KBDCTY16 2-10 Brazil (MS) KBDCTY59 2-11 Bulgaria (Cyrillic) KBDCTY52 2-11 Bulgaria (Latin) KBDCTY53 2-11 Canada (French legacy) KBDCTY54 2-11 Canada (French) KBDCTY18 2-11 Canada (Multilingual) KBDCTY55 2-11 Croatia KBDCTY32 2-11 Czech KBDCTY15 2-11 * Indicates default 11 - 7 Selection Program Keyboard Country 11 - 8 Setting Serial Command # Indicates a numeric entry Page Czech (Programmers) KBDCTY40 2-11 Czech (QWERTY) KBDCTY39 2-11 Czech (QWERTZ) KBDCTY38 2-11 Denmark KBDCTY8 2-11 Dutch (Netherlands) KBDCTY11 2-11 Estonia KBDCTY41 2-12 Faeroese KBDCTY83 2-12 Finland KBDCTY2 2-12 France KBDCTY3 2-12 Gaelic KBDCTY84 2-12 Germany KBDCTY4 2-12 Greek KBDCTY17 2-12 Greek (220 Latin) KBDCTY64 2-12 Greek (220) KBDCTY61 2-12 Greek (319 Latin) KBDCTY65 2-12 Greek (319) KBDCTY62 2-12 Greek (Latin) KBDCTY63 2-12 Greek (MS) KBDCTY66 2-12 Greek (Polytonic) KBDCTY60 2-13 Hebrew KBDCTY12 2-13 Hungarian (101 key) KBDCTY50 2-13 Hungary KBDCTY19 2-13 Iceland KBDCTY75 2-13 Irish KBDCTY73 2-13 Italian (142) KBDCTY56 2-13 Italy KBDCTY5 2-13 Japan ASCII KBDCTY28 2-13 Kazakh KBDCTY78 2-13 Kyrgyz (Cyrillic) KBDCTY79 2-13 Latin America KBDCTY14 2-13 Latvia KBDCTY42 2-13 * Indicates default Selection Program Keyboard Country Setting Serial Command * Indicates default # Indicates a numeric entry Page Latvia (QWERTY) KBDCTY43 2-14 Lithuania KBDCTY44 2-14 Lithuania (IBM) KBDCTY45 2-14 Macedonia KBDCTY34 2-14 Malta KBDCTY74 2-14 Mongolian (Cyrillic) KBDCTY86 2-14 Norway KBDCTY9 2-14 Poland KBDCTY20 2-14 Polish (214) KBDCTY57 2-14 Polish (Programmers) KBDCTY58 2-14 Portugal KBDCTY13 2-14 Romania KBDCTY25 2-14 Russia KBDCTY26 2-14 Russian (MS) KBDCTY67 2-15 Russian (Typewriter) KBDCTY68 2-15 SCS KBDCTY21 2-15 Serbia (Cyrillic) KBDCTY37 2-15 Serbia (Latin) KBDCTY36 2-15 Slovakia KBDCTY22 2-15 Slovakia (QWERTY) KBDCTY49 2-15 Slovakia (QWERTZ) KBDCTY48 2-15 Slovenia KBDCTY31 2-15 Spain KBDCTY10 2-15 Spanish variation KBDCTY51 2-15 Sweden KBDCTY23 2-15 Switzerland (French) KBDCTY29 2-15 Switzerland (German) KBDCTY6 2-16 Tatar KBDCTY85 2-16 Turkey F KBDCTY27 2-16 Turkey Q KBDCTY24 2-16 11 - 9 Selection Program Keyboard Country Keyboard Conversion Keyboard Style Control Character Output 11 - 10 Setting Serial Command * Indicates default # Indicates a numeric entry Page Ukrainian KBDCTY76 2-16 United Kingdom KBDCTY7 2-16 United Stated (Dvorak right) KBDCTY89 2-16 United States (Dvorak left) KBDCTY88 2-16 United States (Dvorak) KBDCTY87 2-16 United States (International) KBDCTY30 2-16 Uzbek (Cyrillic) KBDCTY77 2-16 *Keyboard Conversion Off KBDCNV0 2-18 Convert all Characters to Upper Case KBDCNV1 2-18 Convert all Characters to Lower Case KBDCNV1 2-18 *Regular KBDSTY0 2-17 Caps Lock KBDSTY1 2-17 Shift Lock KBDSTY2 2-17 Automatic Caps Lock KBDSTY6 2-17 Emulate External Keyboard KBDSTY5 2-18 *Control Character Output Off KBDNPE0 2-19 *Control Character Output On KBDNPE1 2-19 Selection Keyboard Modifiers Baud Rate Setting Serial Command * Indicates default # Indicates a numeric entry Page *Control + ASCII Off KBDCAS0 2-20 DOS Mode Control + ASCII KBDCAS1 2-20 Windows Mode Control + ASCII KBDCAS2 2-20 Windows Mode Prefix/Suffix Off KBDCAS3 2-20 *Turbo Mode Off KBDTMD0 2-20 Turbo Mode On KBDTMD1 2-20 *Numeric Keypad Off KBDNPS0 2-20 Numeric Keypad On KBDNPS1 2-20 *Auto Direct Connect Off KBDADC0 2-21 Auto Direct Connect On KBDADC1 2-21 300 BPS 232BAD0 2-22 600 BPS 232BAD1 2-22 1200 BPS 232BAD2 2-22 2400 BPS 232BAD3 2-22 4800 BPS 232BAD4 2-22 *9600 BPS 232BAD5 2-22 19200 BPS 232BAD6 2-22 38400 BPS 232BAD7 2-22 57600 BPS 232BAD8 2-22 115200 BPS 232BAD9 2-22 11 - 11 Selection Setting Serial Command * Indicates default # Indicates a numeric entry Page 7 Data, 1 Stop, Parity Even 232WRD3 2-23 7 Data, 1 Stop, Parity None 232WRD0 2-23 7 Data, 1 Stop, Parity Odd 232WRD6 2-23 7 Data, 2 Stop, Parity Even 232WRD4 2-23 7 Data, 2 Stop, Parity None 232WRD1 2-23 7 Data, 2 Stop, Parity Odd 232WRD7 2-23 8 Data, 1 Stop, Parity Even 232WRD5 2-23 *8 Data, 1 Stop, Parity None 232WRD2 2-23 8 Data, 1 Stop, Parity Odd 232WRD8 2-23 RS232 Receiver Time-out Range 0 - 300 seconds 232LPT### 2-24 RS232 Handshaking *RTS/CTS Off 232CTS0 2-24 Flow Control, No Timeout 232CTS1 2-24 Two-Direction Flow Control 232CTS2 2-24 Flow Control with Timeout 232CTS3 2-24 RS232 Timeout 232DEL#### 2-25 *XON/XOFF Off 232XON0 2-25 XON/XOFF On 232XON1 2-25 *ACK/NAK Off 232ACK0 2-26 ACK/NAK On 232ACK1 2-26 *Packet Mode Off 232PKT0 2-26 Packet Mode On 232PKT2 2-3 Word Length: Data Bits, Stop Bits, and Parity Scanner-Bioptic Packet Mode 11 - 12 Selection Scanner-Bioptic ACK/NAK Mode Scanner-Bioptic ACK/NAK Timeout Setting Serial Command # Indicates a numeric entry Page *Bioptic ACK/NAK Off 232NAK0 2-27 Bioptic ACK/NAK On 232NAK1 2-27 ACK/NAK Timeout *5100 232DLK##### 2-27 * Indicates default Cordless System Operation Note: This section applies only to cordless systems. It does not apply to corded scanners. Base Power Communication Indicator *On BASRED1 3-8 Off BASRED0 3-8 Reset Scanner Reset Scanner RESET_ 3-8 Scanning While in Base Cradle Scanning in Cradle Off BT_SIC0 3-8 *Scanning in Cradle On BT_SIC1 3-8 Shut Down Scanner in Cradle BT_SIC2 3-8 *On BEPPGE1 3-9 Paging Mode Off BEPPGE0 3-9 Paging Pitch Range 400 - 9000 Hz (*1000) BEPPFQ#### 3-9 Beeper Pitch - Base Error *Razz (250) (min 200Hz) BASFQ2250 3-10 Medium (3250) BASFQ23250 3-10 High (4200) (max 9000Hz) BASFQ24200 3-10 Number of Beeps Base Error *1 BASERR3 3-10 Range 1 - 9 BASERR# 3-10 Scanner Report Scanner Report RPTSCN 3-10 Scanner Address Scanner Address BT_LDA 3-11 Base Address Base Address BASLDA 3-11 11 - 13 Selection Scanner Modes Out-of-Range Alarm Alarm Sound Type Flexible Power Management Reset Batch Mode Batch Mode Beep Batch Mode Storage Batch Mode Quantity 11 - 14 Setting Serial Command * Indicates default # Indicates a numeric entry Page Charge Only Mode BASLNK0 3-11 *Charge and Link Mode BASLNK1 3-12 Locked Link Mode BASCON0,DNG1 3-13 *Open Link Mode BASCON1,DNG1 3-13 Unlink Scanner BT_RMV 3-13 Override Locked Scanner BT_RPL1 3-13 Base Alarm Duration (Range 1 3000 sec (*0)) BASORD 3-14 Scanner Alarm Duration (Range 1 3000 sec (*0)) BT_ORD 3-14 Base Alarm Type BASORW 3-14 Scanner Alarm Type BT_ORW 3-14 *Full Power BT_TXP100 3-15 Medium Power BT_TXP35 3-15 Medium Low Power BT_TXP5 3-15 Low Power BT_TXP1 3-15 Reset Base RESET_ 3-16 Reset Scanner :*:RESET_ 3-16 Automatic Batch Mode BATENA1 3-17 *Batch Mode Off BATENA0 3-17 Inventory Batch Mode BATENA2 3-17 Off BATBEP0 3-17 *On BATBEP1 3-17 *Flash Storage BATNVS1 3-18 RAM Storage BATNVS0 3-18 *Off BATQTY0 3-18 On BATQTY1 3-18 Selection Quantity Codes Setting Serial Command * Indicates default # Indicates a numeric entry Page 0 BATNUM0 3-19 *1 BATNUM1 3-19 2 BATNUM2 3-19 3 BATNUM3 3-19 4 BATNUM4 3-19 5 BATNUM5 3-19 6 BATNUM6 3-19 7 BATNUM7 3-19 8 BATNUM8 3-20 9 BATNUM9 3-20 Batch Mode Output Order FIFO BATLIF0 3-20 LIFO BATLIF1 3-20 Delete Last Code Delete Last Code BATUND 3-20 Clear All Codes Clear All Codes BATCLR 3-20 Transmit Records to Host Transmit Inventory Records BAT_TX 3-21 Batch Mode Transmit Delay *Off BATDLY0 3-21 Short (ms) BATDLY250 3-21 Medium (ms) BATDLY500 3-21 Long (ms) BATDLY1000 3-21 Multiple Scanner Operation BASCON2,DNG3 3-22 Multiple Scanner Operation Scanner Name Name 1-7 BT_NAM##### 3-23 Reset RESET_ 3-23 Scanner Name BT_NAM 3-23 Application Work Group Selections *Group 0 GRPSEL0 3-25 Group 1-6 GRPSEL# 3-25 Resetting the Factory Defaults: All Application Work Groups Factory Default Settings: All Work Groups PAPDFT& 3-25 11 - 15 Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Resetting the Custom Defaults: All Application Work Groups Custom Default Settings: All Work Groups PAPDFT 3-26 Bluetooth Connection PCs/Laptops: Non-Base BT Connection BT_DNG5 3-27 BT Connection PDA/Mobility Systems Device BT_DNG1 3-27 Bluetooth PIN Code Bluetooth PIN BT_PIN 3-27 Auto Reconnect Mode *Auto Reconnect On BT_ACM1 3-28 Auto Reconnect Off BT_ACM0 3-28 Maximum Link Attempts Maximum Link Attempts BT_MLA 3-29 Relink Time-Out Relink Time-Out BT_RLT 3-30 Host Command Acknowledgment Host ACK On HSTACK1 3-32 *Host ACK Off HSTACK0 3-32 Power Up Beeper Off - Scanner BEPPWR0 4-1 *Power Up Beeper On - Scanner BEPPWR1 4-1 Power Up Beeper Off - Cordless Base BASPWR0 4-1 Power Up Beeper On - Cordless Base BASPWR1 4-1 Beep on BEL Character Beep on BEL On BELBEP1 4-1 *Beep on BEL Off BELBEP0 4-1 Trigger Click On BEPTRG1 4-2 *Off BEPTRG0 4-2 Beeper - Good Read Off BEPBEP0 4-3 *On BEPBEP1 4-2 Input/Output Selections Power Up Beeper 11 - 16 Setting Serial Command * Indicates default # Indicates a numeric entry Page Off BEPLVL0 4-2 Low BEPLVL1 4-3 Medium BEPLVL2 4-3 *High BEPLVL3 4-3 Low (1600) (min 400Hz) BEPFQ11600 4-3 *Medium 2700) BEPFQ12700 4-3 High (4200) (max 9000Hz) BEPFQ14200 4-3 *Razz (250) (min 200Hz) BEPFQ2800 4-4 Medium (3250) BEPFQ23250 4-4 High (4200) (max 9000Hz) BEPFQ24200 4-4 Beeper Duration Good Read *Normal Beep BEPBIP0 4-4 Short Beep BEPBIP1 4-4 LED - Good Read Off BEPLED0 4-4 Selection Beeper Volume Good Read Beeper Pitch - Good Read (Frequency) Beeper Pitch - Error (Frequency) *On BEPLED1 4-4 Number of Beeps Error *1 BEPERR3 4-5 Range 1 - 9 BEPERR# 4-5 Number of Beeps Good Read *1 BEPRPT1 4-5 Range 1 - 9 BEPRPT# 4-5 Good Read Delay *No Delay DLYGRD0 4-6 Short Delay (500 ms) DLYGRD500 4-6 Medium Delay (1000 ms) DLYGRD1000 4-6 Long Delay (1500 ms) DLYGRD1500 4-6 Range 0 - 30,000 ms DLYGRD##### 4-6 User-Specified Good Read Delay 11 - 17 Selection Manual Trigger Modes Serial Trigger Mode Setting Serial Command # Indicates a numeric entry Page *Manual Trigger Normal PAPHHF 4-7 Manual Trigger Enhanced PAPHHS 4-7 Read Time-Out (0 - 300,000 ms) *30,000 TRGSTO#### 4-7 Scanner Power Time-Out Timer (07200 seconds) *3600 BT_LPT0 4-8 BT_LPT200 4-8 BT_LPT400 4-8 BT_LPT900 4-8 BT_LPT3600 4-8 BT_LPT7200 4-8 * Indicates default Presentation Presentation Mode TRGMOD3 4-9 Presentation LED Behavior After Decode *LEDs On TRGPCK1 4-9 LEDs Off TRGPCK0 4-9 Presentation Sensitivity Range 0-20 (*1) TRGPMS## 4-9 11 - 18 Setting Serial Command # Indicates a numeric entry Page Presentation Centering On PDCWIN1 4-11 *Presentation Centering Off PDCWIN0 4-11 Left of Presentation Centering Window (*40%) PDCLFT### 4-11 Right of Presentation Centering Window (*60%) PDCRGT### 4-11 Top of Presentation Centering Window (*40%) PDCTOP### 4-11 Bottom of Presentation Centering Window (*60%) PDCBOT### 4-11 In-Stand Sensor Mode Sensor On TRGSSW1 4-11 Sensor Off TRGSSW0 4-11 CodeGate *CodeGate Off Outof-Stand AOSCGD0. 4-12 CodeGate On Outof-Stand AOSCGD1. 4-12 Streaming Presentation Mode Normal PAPSPN 4-12 Streaming Presentation Mode Enhanced PAPSPE 4-12 Hand Held Scanning - Mobile Phone PAPHHC 4-13 Streaming Presentation Mobile Phone PAPSPC 4-13 Selection Presentation Centering Window Streaming Presentation Mobile Phone Read Mode * Indicates default 11 - 19 Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Image Snap and Ship Image Snap and Ship TRGMOD6 4-14 Hands Free TimeOut Range 0 - 300,000 ms TRGPTO###### 4-14 Reread Delay Short (500 ms) DLYRRD500 4-15 *Medium (750 ms) DLYRRD750 4-15 Long (1000 ms) DLYRRD1000 4-15 Extra Long (2000 ms) DLYRRD2000 4-14 Range 0 - 30,000 ms DLYRRD##### 4-15 *Lights On SCNLED1 4-15 Lights Off SCNLED0 4-15 200 milliseconds SCNDLY200 4-16 400 milliseconds SCNDLY400 4-16 User-Specified Reread Delay Illumination Lights Aimer Delay *Off (no delay) SCNDLY0 4-16 User-Specified Aimer Delay Range 0 - 4,000 ms SCNDLY#### 4-16 Scanner Time-Out 0 - 999,999 ms SDRTIM#### 4-16 Aimer Mode Off SCNAIM0 4-17 *Interlaced SCNAIM2 4-17 Centering Window Centering On DECWIN1 4-19 *Centering Off DECWIN0 4-19 Left of Centering Window (*40%) DECLFT### 4-19 Right of Centering Window (*60%) DECRGT### 4-19 Top of Centering Window (*40%) DECTOP### 4-19 Bottom of Centering Window (*60%) DECBOT### 4-19 11 - 20 Selection Preferred Symbology Setting Serial Command * Indicates default # Indicates a numeric entry Page On PRFENA1 4-20 *Off PRFENA0 4-20 High Priority Symbology PRFCOD## 4-20 Low Priority Symbology PRFBLK## 4-20 Preferred Symbology Timeout (*500) Range 1003000 PRFPTO#### 4-21 Preferred Symbology Default PRFDFT 4-21 Output Sequence Editor Enter Sequence SEQBLK 4-24 Default Sequence SEQDFT 4-24 Partial Sequence Transmit Partial Sequence SEQTTS1 4-24 *Discard Partial Sequence SEQTTS0 4-24 Required SEQ_EN2 4-25 On/Not Required SEQ_EN1 4-25 *Off SEQ_EN0 4-25 Require Output Sequence Multiple Symbols No Read Video Reverse On SHOTGN1 4-25 *Off SHOTGN0 4-25 On SHWNRD1 4-26 *Off SHWNRD0 4-26 Video Reverse Only VIDREV1 4-26 Video Reverse and Standard Bar Codes VIDREV2 4-26 *Video Reverse Off VIDREV0 4-26 11 - 21 Setting Serial Command * Indicates default # Indicates a numeric entry Page *Upright ROTATN0 4-27 Vertical, Bottom to Top (Rotate CCW 90°) ROTATN1 4-27 Upside Down ROTATN2 4-27 Vertical, Top to Bottom (Rotate CW 90°) ROTATN3 4-27 Add CR Suffix to All Symbologies VSUFCR 5-3 Prefix Add Prefix PREBK2## 5-3 Clear One Prefix PRECL2 5-3 Clear All Prefixes PRECA2 5-3 Add Suffix SUFBK2## 5-4 Clear One Suffix SUFCL2 5-4 Clear All Suffixes SUFCA2 5-4 Selection Working Orientation Prefix/Suffix Selections Suffix Function Code Transmit *Enable RMVFNC0 5-4 Disable RMVFNC1 5-4 Intercharacter Delay Range 0 - 1000 (5ms increments) DLYCHR## 5-5 User Specified Intercharacter Delay Delay Length 0 - 1000 (5ms increments) DLYCRX## 5-5 Character to Trigger Delay DLY_XX## 5-5 Interfunction Delay Range 0 - 1000 (5ms increments) DLYFNC## 5-6 Intermessage Delay Range 0 - 1000 (5ms increments) DLYMSG## 5-6 11 - 22 Selection Setting Serial Command # Indicates a numeric entry Page *Default Data Format (None) DFMDF3 6-1 Enter Data Format DFMBK3## 6-2 Clear One Data Format DFMCL3 6-3 Clear All Data Formats DFMCA3 6-3 Data Formatter Off DFM_EN0 6-9 *Data Formatter On, Not Required, Keep Prefix/Suffix DFM_EN1 6-10 Data Format Required, Keep Prefix/Suffix DFM_EN2 6-10 Data Formatter On, Not Required, Drop Prefix/Suffix DFM_EN3 6-10 Data Format Required, Drop Prefix/Suffix DFM_EN4 6-10 *Data Format NonMatch Error Tone On DFMDEC0 6-11 Data Format NonMatch Error Tone Off DFMDEC1 6-11 Primary Data Format ALTFNM0 6-11 Data Format 1 ALTFNM1 6-11 Data Format 2 ALTFNM2 6-11 Data Format 3 ALTFNM3 6-11 * Indicates default Data Formatter Selections Data Format Editor Data Formatter Data Format NonMatch Error Tone Primary/Alternate Data Formats 11 - 23 Setting Serial Command # Indicates a numeric entry Page Single Scan-Primary Data Format VSAF_0 6-12 Single Scan-Data Format 1 VSAF_1 6-12 Single Scan-Data Format 2 VSAF_2 6-12 Single Scan-Data Format 3 VSAF_3 6-12 All Symbologies All Symbologies Off ALLENA0 7-2 All Symbologies On ALLENA1 7-2 Codabar Default All Codabar Settings CBRDFT 7-3 Off CBRENA0 7-3 Selection Single Scan Data Format Change * Indicates default Symbologies *On CBRENA1 7-3 Codabar Start/Stop Char. *Don’t Transmit CBRSSX0 7-3 Transmit CBRSSX1 7-3 Codabar Check Char. *No Check Char. CBRCK20 7-4 Validate, But Don’t Transmit CBRCK21 7-4 Validate, and Transmit CBRCK22 7-4 *Off CBRCCT0 7-4 On CBRCCT1 7-4 Require CBRCCT2 7-4 Codabar Concatenation Codabar Message Length Minimum (2 - 60) *4 CBRMIN## 7-5 Maximum (2 - 60) *60 CBRMAX## 7-5 Code 39 Default All Code 39 Settings C39DFT 7-6 Off C39ENA0 7-6 *On C39ENA1 7-6 11 - 24 Setting Serial Command * Indicates default # Indicates a numeric entry Page Code 39 Start/Stop Char. *Don’t Transmit C39SSX0 7-6 Transmit C39SSX1 7-6 Code 39 Check Char. *No Check Char. C39CK20 7-7 Validate, But Don’t Transmit C39CK21 7-7 Validate, and Transmit C39CK22 7-7 Code 39 Message Length Minimum (0 - 48) *0 C39MIN## 7-7 Maximum (0 - 48) *48 C39MAX## 7-7 Code 39 Append *Off C39APP0 7-8 Selection On C39APP1 7-8 Code 32 Pharmaceutical (PARAF) *Off C39B320 7-8 On C39B321 7-8 Code 39 Full ASCII *Off C39ASC0 7-9 On C39ASC1 7-9 Code 39 Code Page C39DCP 7-10 Default All Interleaved 2 of 5 Settings I25DFT 7-10 Off I25ENA0 7-10 *On I25ENA1 7-10 *No Check Char. I25CK20 7-11 Validate, But Don’t Transmit I25CK21 7-11 Validate, and Transmit I25CK22 7-11 Minimum (2 - 80) *4 I25MIN## 7-11 Maximum (2 - 80) *80 I25MAX## 7-11 Interleaved 2 of 5 Interleaved 2 of 5 Check Digit Interleaved 2 of 5 Message Length 11 - 25 Setting Serial Command # Indicates a numeric entry Page Default All NEC 2 of 5 Settings N25DFT 7-12 Off N25ENA0 7-12 *On N25ENA1 7-12 *No Check Char. N25CK20 7-12 Validate, But Don’t Transmit N25CK21 7-12 Validate, and Transmit N25CK22 7-12 NEC 2 of 5 Message Length Minimum (2 - 80) *4 N25MIN## 7-13 Maximum (2 - 80) *80 N25MAX## 7-13 Code 93 Default All Code 93 Settings C93DFT 7-14 Off C93ENA0 7-14 *On C93ENA1 7-16 Code 93 Message Length Minimum (0 - 80) *0 C93MIN## 7-14 Maximum (0 - 80) *80 C93MAX## 7-14 Code 93 Append On C93APP1 7-15 *Off C93APP0 7-15 Code 93 Code Page Code 93 Code Page C93DCP 7-15 Straight 2 of 5 Industrial Default All Straight 2 of 5 Industrial Settings R25DFT 7-16 *Off R25ENA0 7-16 On R25ENA1 7-16 Straight 2 of 5 Industrial Message Length Minimum (1 - 48) *4 R25MIN## 7-16 Maximum (1 - 48) *48 R25MAX## 7-16 Straight 2 of 5 IATA Default All Straight 2 of 5 IATA Settings A25DFT 7-17 Selection NEC 2 of 5 NEC 2 of 5 Check Digit 11 - 26 * Indicates default Selection Straight 2 of 5 IATA Setting Serial Command * Indicates default # Indicates a numeric entry Page *Off A25ENA0 7-17 On A25ENA1 7-17 Straight 2 of 5 IATA Message Length Minimum (1 - 48) *4 A25MIN## 7-17 Maximum (1 - 48) *48 A25MAX## 7-17 Matrix 2 of 5 Default All Matrix 2 of 5 Settings X25DFT 7-18 *Off X25ENA0 7-18 On X25ENA1 7-18 Matrix 2 of 5 Message Length Minimum (1 - 80) *4 X25MIN## 7-18 Maximum (1 - 80) *80 X25MAX## 7-18 Code 11 Default All Code 11 Settings C11DFT 7-19 *Off C11ENA0 7-19 On C11ENA1 7-19 Code 11 Check Digits Required 1 Check Digit C11CK20 7-19 *2 Check Digits C11CK21 7-19 Code 11 Message Length Minimum (1 - 80) *4 C11MIN## 7-20 Maximum (1 - 80) *80 C11MAX## 7-20 Code 128 Default All Code 128 Settings 128DFT 7-20 Off 128ENA0 7-20 *On 128ENA1 7-20 *Off ISBENA0 7-21 ISBT Concatenation On ISBENA1 7-21 Code 128 Message Length Minimum (0 - 80) *0 128MIN## 7-21 Maximum (0 - 80) *80 128MAX## 7-21 Code 128 Append On 128APP1 7-21 *Off 128APP0 7-21 11 - 27 Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Code 128 Code Page Code 128 Code Page (*2) 128DCP## 7-22 GS1-128 Default All GS1-128 Settings GS1DFT 7-23 *On GS1ENA1 7-23 Off GS1ENA0 7-23 GS1-128 Message Length Minimum (1 - 80) *1 GS1MIN 7-23 Maximum (0 - 80) *80 GS1MAX 7-23 Telepen Default All Telepen Settings TELDFT 7-24 *Off TELENA0 7-24 On TELENA1 7-24 *AIM Telepen Output TELOLD0 7-24 Original Telepen Output TELOLD1 7-24 Telepen Message Length Minimum (1 - 60) *1 TELMIN## 7-25 Maximum (1 - 60) *60 TELMAX## 7-25 UPC-A Default All UPC-A Settings UPADFT 7-25 Off UPAENA0 7-25 *On UPAENA1 7-25 Off UPACKX0 7-25 *On UPACKX1 7-25 UPC-A Number System Off UPANSX0 7-26 *On UPANSX1 7-26 UPC-A 2 Digit Addenda *Off UPAAD20 7-26 On UPAAD21 7-26 UPC-A 5 Digit Addenda *Off UPAAD50 7-26 On UPAAD51 7-26 UPC-A Addenda Required *Not Required UPAARQ0 7-26 Required UPAARQ1 7-26 Telepen Output UPC-A Check Digit 11 - 28 Setting Serial Command * Indicates default # Indicates a numeric entry Page UPC-A Addenda Separator Off UPAADS0 7-27 *On UPAADS1 7-27 UPC-A/EAN-13 with Extended Coupon Code *Off CPNENA0 7-27 Allow Concatenation CPNENA1 7-27 Require Concatenation CPNENA2 7-27 Coupon GS1 DataBar Output GS1 Output Off CPNGS10 7-28 GS1 Output On CPNGS11 7-28 UPC-E0 Default All UPC-E Settings UPEDFT 7-28 Off UPEEN00 7-28 *On UPEEN01 7-28 *Off UPEEXP0 7-29 On UPEEXP1 7-29 Selection UPC-E0 Expand UPC-E0 Addenda Required Required UPEARQ1 7-29 *Not Required UPEARQ0 7-29 UPC-E0 Addenda Separator *On UPEADS1 7-29 Off UPEADS0 7-29 UPC-E0 Check Digit Off UPECKX0 7-30 *On UPECKX1 7-30 UPC-E0 Number System Off UPENSX0 7-30 *On UPENSX1 7-30 UPC-E0 Addenda 2 Digit Addenda On UPEAD21 7-30 *2 Digit Addenda Off UPEAD20 7-30 5 Digit Addenda On UPEAD51 7-30 *5 Digit Addenda Off UPEAD50 7-30 UPC-E1 EAN/JAN-13 *Off UPEEN10 7-31 On UPEEN11 7-31 Default All EAN/ JAN Settings E13DFT 7-31 Off E13ENA0 7-31 *On E13ENA1 7-31 11 - 29 Setting Serial Command * Indicates default # Indicates a numeric entry Page EAN/JAN-13 Check Digit Off E13CKX0 7-31 *On E13CKX1 7-31 EAN/JAN-13 2 Digit Addenda 2 Digit Addenda On E13AD21 7-32 *2 Digit Addenda Off E13AD20 7-32 5 Digit Addenda On E13AD51 7-32 Selection *5 Digit Addenda Off E13AD50 7-32 EAN/JAN-13 Addenda Required *Not Required E13ARQ0 7-32 Required E13ARQ1 7-32 EAN/JAN-13 Addenda Separator Off E13ADS0 7-33 *On E13ADS1 7-33 ISBN Translate *Off E13ISB0 7-33 On E13ISB1 7-33 EAN/JAN-8 Default All EAN/ JAN 8 Settings EA8DFT 7-34 Off EA8ENA0 7-34 *On EA8ENA1 7-34 EAN/JAN-8 Check Digit Off EA8CKX0 7-34 *On EA8CKX1 7-34 EAN/JAN-8 Addenda *2 Digit Addenda Off EA8AD20 7-35 2 Digit Addenda On EA8AD21 7-35 *5 Digit Addenda Off EA8AD50 7-35 5 Digit Addenda On EA8AD51 7-35 EAN/JAN-8 Addenda Required *Not Required EA8ARQ0 7-35 Required EA8ARQ1 7-35 EAN/JAN-8 Addenda Separator Off EA8ADS0 7-35 *On EA8ADS1 7-35 MSI Default All MSI Settings MSIDFT 7-36 *Off MSIENA0 7-36 On MSIENA1 7-36 11 - 30 Selection MSI Check Character MSI Message Length GS1 DataBar Omnidirectional GS1 DataBar Limited Setting Serial Command # Indicates a numeric entry Page *Validate Type 10, but Don’t Transmit MSICHK0 7-37 Validate Type 10 and Transmit MSICHK1 7-37 Validate 2 Type 10 Chars, but Don’t Transmit MSICHK2 7-37 Validate 2 Type 10 Chars and Transmit MSICHK3 7-37 Validate Type 10 then Type 11 Char, but Don’t Transmit MSICHK4 7-37 Validate Type 10 then Type 11 Char and Transmit MSICHK5 7-37 Disable MSI Check Characters MSICHK6 7-37 Minimum (4 - 48) *4 MSIMIN## 7-37 Maximum (4 - 48) *48 MSIMAX## 7-37 Default All GS1 DataBar Omnidirectional Settings RSSDFT 7-38 Off RSSENA0 7-38 *On RSSENA1 7-38 Default All GS1 DataBar Limited Settings RSLDFT 7-38 Off RSLENA0 7-38 *On RSLENA1 7-38 * Indicates default 11 - 31 Selection GS1 DataBar Expanded Setting Serial Command # Indicates a numeric entry Page Default All GS1 DataBar Expanded Settings RSEDFT 7-39 Off RSEENA0 7-39 * Indicates default *On RSEENA1 7-39 GS1 DataBar Expanded Msg. Length Minimum (4 - 74) *4 RSEMIN## 7-39 Maximum (4 - 74) *74 RSEMAX## 7-39 Trioptic Code *Off TRIENA0 7-40 On TRIENA1 7-40 Default All Codablock A Settings CBADFT 7-40 *Off CBAENA0 7-40 On CBAENA1 7-40 Minimum (1 - 600) *1 CBAMIN#### 7-41 Maximum (1 - 600) *600 CBAMAX#### 7-41 Default All Codablock F Settings CBFDFT 7-40 *Off CBFENA0 7-42 On CBFENA1 7-42 Minimum (1 - 2048) *1 CBFMIN#### 7-42 Maximum (1 - 2048) *2048 CBFMAX#### 7-42 Default All PDF417 Settings PDFDFT 7-43 *On PDFENA1 7-43 Off PDFENA0 7-43 Codablock A Codablock A Msg. Length Codablock F Codablock F Msg. Length PDF417 11 - 32 Selection PDF417 Msg. Length MicroPDF417 Setting Serial Command # Indicates a numeric entry Page Minimum (1-2750) *1 PDFMIN 7-43 Maximum (1-2750) *2750 PDFMAX 7-43 Default All Micro PDF417 Settings MPDDFT 7-44 On MPDENA1 7-44 * Indicates default *Off MPDENA0 7-44 MicroPDF417 Msg. Length Minimum (1-366) *1 MPDMIN 7-44 Maximum (1-366) *366 MPDMAX 7-44 GS1 Composite Codes On COMENA1 7-45 *Off COMENA0 7-45 UPC/EAN Version On COMUPC1 7-45 *Off COMUPC0 7-45 Minimum (1-2435) *1 COMMIN 7-45 Maximum (1-2435) *2435 COMMAX 7-45 GS1-128 Emulation EANEMU1 7-46 GS1 DataBar Emulation EANEMU2 7-46 GS1 Code Expansion Off EANEMU3 7-46 EAN8 to EAN13 Conversion EANEMU4 7-46 *GS1 Emulation Off EANEMU0 7-46 On T39ENA1 7-47 *Off T39ENA0 7-47 Default All QR Code Settings QRCDFT 7-54 *On QRCENA1 7-47 Off QRCENA0 7-47 GS1 Composite Codes Msg. Length GS1 Emulation TCIF Linked Code 39 QR Code 11 - 33 Selection Setting Serial Command # Indicates a numeric entry Page Minimum (1-7089) *1 QRCMIN 7-48 Maximum (1-7089) *7089 QRCMAX 7-48 QR Code Page QR Code Page (*3) QRCDCP## 7-48 Data Matrix Default All Data Matrix Settings IDMDFT 7-49 *On IDMENA1 7-49 Off IDMENA0 7-49 Minimum (1-3116) *1 IDMMIN 7-49 Maximum (1-3116) *3116 IDMMAX 7-49 Data Matrix Code Page Data Matrix Code Page (*51) IDMDCP## 7-50 Low Density Data Matrix Low Density Codes On IDMBST1 7-50 *Low Density Codes Off IDMBST0 7-50 Default All MaxiCode Settings MAXDFT 7-51 On MAXENA1 7-51 QR Code Msg. Length Data Matrix Msg. Length MaxiCode * Indicates default *Off MAXENA0 7-51 MaxiCode Msg. Length Minimum (1-150) *1 MAXMIN 7-51 Maximum (1-150) *150 MAXMAX 7-51 Aztec Code Default All Aztec Code Settings AZTDFT 7-52 *On AZTENA1 7-52 Off AZTENA0 7-52 Minimum (1-3832) *1 AZTMIN 7-52 Maximum (1-3832) *3832 AZTMAX 7-52 Aztec Code Msg. Length 11 - 34 Selection Aztec Append Setting Serial Command * Indicates default # Indicates a numeric entry Page On AZTAPP1 7-53 *Off AZTAPP0 7-53 Aztec Code Page Aztec Code Page (*51) AZTDCP## 7-53 Chinese Sensible (Han Xin) Code Default All Han Xin Code Settings HX_DFT 7-54 On HX_ENA1 7-54 *Off HX_ENA0 7-54 Minimum (1-7833) *1 HX_MIN 7-54 Maximum (1-7833) *7833 HX_MAX 7-54 2D Postal Codes *Off POSTAL0 7-55 Single 2D Postal Codes Australian Post On POSTAL1 7-55 British Post On POSTAL7 7-55 Canadian Post On POSTAL30 7-55 Intelligent Mail Bar Code On POSTAL10 7-55 Japanese Post On POSTAL3 7-55 KIX Post On POSTAL4 7-55 Planet Code On POSTAL5 7-55 Postal-4i On POSTAL9 7-55 Postnet On POSTAL6 7-56 Postnet with B and B’ Fields On POSTAL11 7-56 InfoMail On POSTAL2 7-56 Chinese Sensible (Han Xin) Code Msg. Length Postal Codes - 2D 11 - 35 Selection Combination 2D Postal Codes 11 - 36 Setting Serial Command # Indicates a numeric entry Page InfoMail and British Post On POSTAL8 7-56 Intelligent Mail Bar Code and Postnet with B and B’ Fields On POSTAL20 7-56 Postnet and Postal4i On POSTAL14 7-56 Postnet and Intelligent Mail Bar Code On POSTAL16 7-56 Postal-4i and Intelligent Mail Bar Code On POSTAL17 7-56 Postal-4i and Postnet with B and B’ Fields On POSTAL19 7-56 Planet and Postnet On POSTAL12 7-56 Planet and Postnet with B and B’ Fields On POSTAL18 7-56 Planet and Postal-4i On POSTAL13 7-57 Planet and Intelligent Mail Bar Code On POSTAL15 7-57 Planet, Postnet, and Postal-4i On POSTAL21 7-57 Planet, Postnet, and Intelligent Mail Bar Code On POSTAL22 7-57 Planet, Postal-4i, and Intelligent Mail Bar Code On POSTAL23 7-57 * Indicates default Selection Setting Serial Command # Indicates a numeric entry Page Postnet, Postal-4i, and Intelligent Mail Bar Code On POSTAL24 7-57 Planet, Postal-4i, and Postnet with B and B’ Fields On POSTAL25 7-57 Planet, Intelligent Mail Bar Code, and Postnet with B and B’ Fields On POSTAL26 7-57 Postal-4i, Intelligent Mail Bar Code, and Postnet with B and B’ Fields On POSTAL27 7-57 Planet, Postal-4i, Intelligent Mail Bar Code, and Postnet On POSTAL28 7-57 Planet, Postal-4i, Intelligent Mail Bar Code, and Postnet with B and B’ Fields On POSTAL29 7-57 Planet Code Check Digit Transmit PLNCKX1 7-58 *Don’t Transmit PLNCKX0 7-58 Postnet Check Digit Transmit NETCKX1 7-58 *Don’t Transmit NETCKX0 7-58 Bar Output AUSINT0 7-59 Numeric N Table AUSINT1 7-59 Alphanumeric C Table AUSINT2 7-59 Combination N and C Tables AUSINT3 7-59 Combination 2D Postal Codes (continued) Australian Post Interpretation * Indicates default Postal Codes - Linear 11 - 37 Selection China Post (Hong Kong 2 of 5) Setting Serial Command # Indicates a numeric entry Page Default All China Post (Hong Kong 2 of 5) Settings CPCDFT 7-59 *Off CPCENA0 7-60 * Indicates default On CPCENA1 7-60 China Post (Hong Kong 2 of 5) Msg. Length Minimum (2 - 80) *4 CPCMIN## 7-60 Maximum (2 - 80) *80 CPCMAX## 7-60 Korea Post Default All Korea Post Settings KPCDFT 7-61 *Off KPCENA0 7-61 On KPCENA1 7-61 Korea Post Msg. Length Minimum (2 - 80) *4 KPCMIN## 7-61 Maximum (2 - 80) *48 KPCMAX## 7-61 Korea Post Check Digit Transmit Check Digit KPCCHK1 7-61 *Don’t Transmit Check Digit KPCCHK0 7-61 11 - 38 Selection Setting Serial Command # Indicates a numeric entry Page Default all Imaging Commands IMGDFT 8-1 Imaging Style Decoding SNPSTY0 8-2 *Imaging Style Photo SNPSTY1 8-2 Imaging Style Manual SNPSTY2 8-2 Beeper On SNPBEP1 8-2 *Beeper Off SNPBEP0 8-2 *Wait for Trigger Off SNPTRG0 8-2 Wait for Trigger On SNPTRG1 8-2 *LED State - Off SNPLED0 8-2 LED State - On SNPLED1 8-2 Exposure (1-7874 microseconds) SNPEXP 8-3 *Gain - None SNPGAN1 8-3 Gain - Medium SNPGAN2 8-3 Gain - Heavy SNPGAN4 8-3 Gain - Maximum SNPGAN8 8-3 Target White Value (0-255) *125 SNPWHT### 8-4 Delta for Acceptance (0-255) *25 SNPDEL### 8-4 Update Tries (0-10) *6 SNPTRY## 8-4 Target Set Point Percentage (1-99) *50 SNPPCT## 8-4 * Indicates default Imaging Default Commands Image Snap 11 - 39 Selection Image Ship 11 - 40 Setting Serial Command * Indicates default # Indicates a numeric entry Page *Infinity Filter - Off IMGINF0 8-5 Infinity Filter - On IMGINF1 8-5 *Compensation Off IMGCOR0 8-6 Compensation On IMGCOR1 8-6 *Pixel Depth - 8 bits/ pixel (grayscale) IMGBPP8 8-6 Pixel Depth - 1 bit/ pixel (B&W) IMGBPP1 8-6 *Don’t Sharpen Edges IMGEDG0 8-7 Sharpen Edges (023) IMGEDG## 8-7 *File Format - JPEG IMGFMT6 8-7 File Format - KIM IMGFMT0 8-7 File Format - TIFF binary IMGFMT1 8-7 File Format - TIFF binary group 4, compressed IMGFMT2 8-7 File Format - TIFF grayscale IMGFMT3 8-7 File Format Uncompressed binary IMGFMT4 8-7 File Format Uncompressed grayscale IMGFMT5 8-7 File Format - BMP IMGFMT8 8-7 *Histogram Stretch Off IMGHIS0 8-8 Histogram Stretch On IMGHIS1 8-8 *Noise Reduction Off IMGFSP0 8-9 Noise Reduction On IMGFSP1 8-9 Selection Image Ship (continued) Setting Serial Command # Indicates a numeric entry Page Invert Image around X axis IMGNVX1 8-8 Invert Image around Y axis IMGNVY1 8-8 Rotate Image none IMGROT0 8-9 Rotate Image 90° right IMGROT1 8-9 Rotate Image 180° right IMGROT2 8-9 Rotate Image 90° left IMGROT3 8-9 JPEG Image Quality (0-100) *50 IMGJQF### 8-10 *Gamma Correction Off IMGGAM0 8-10 Gamma Correction On (0-1000) IMGGAM### 8-10 Image Crop - Left (0640) *0 IMGWNL### 8-10 Image Crop - Right (0-640) *639 IMGWNR### 8-10 Image Crop - Top (0480) *0 IMGWNT### 8-10 Image Crop Bottom (0-480) *479 IMGWNB### 8-11 Image Crop - Margin (1-238) *0 IMGMAR### 8-11 Protocol - None (raw) IMGXFR0 8-11 Protocol - None (default USB) IMGXFR2 8-11 Protocol - Hmodem Compressed IMGXFR3 8-11 Protocol - Hmodem IMGXFR4 8-11 Ship Every Pixel IMGSUB1 8-12 * Indicates default 11 - 41 Selection Image Ship (continued) Image Size Compatibility Intelligent Signature Capture 11 - 42 Setting Serial Command * Indicates default # Indicates a numeric entry Page Ship Every 2nd Pixel IMGSUB2 8-12 Ship Every 3rd Pixel IMGSUB3 8-12 *Document Image Filter Off IMGUSH0 8-12 Document Image Filter On (0-255) IMGUSH### 8-12 *Don’t Ship Histogram IMGHST0 8-13 Ship Histogram IMGHST1 8-13 Force VGA Resolution IMGVGA1 8-14 *Native Resolution IMGVGA0 8-14 Optimize On DECBND1 8-14 *Optimize Off DECBND0 8-14 12 Product Specifications 1900 Scanner Product Specifications Parameter Specification Dimensions (Typical): Height 6.3 inches (16cm) Length 4.1 inches (10.41cm) Width 2.8 inches (7.11cm) Weight 5.2 ounces (147.42g) Illumination: Scan and Aiming LEDs LED output power 617nm + 18nm .339mW Image Size 838 x 640 pixels Skew Angle +65° Pitch Angle +45° Motion Tolerance: Streaming Presentation Trigger up to 240 inches per second for 13 mil UPC Symbol Contrast Grade 1.0 (20% or greater) Voltage Requirements 4 - 5.5 VDC at input connector Current Draw @5VDC Scanning 450mA, 2.3W Power Supply Noise Rejection Maximum 100mV peak to peak, 10 to 100 kHz Standby 90mA, .45W Temperature Ranges: Operating Storage +32°F to +122°F (0°C to 50°C) -40°F to +158°F (-40°C to 70°C) Humidity 0 to 95% non-condensing Mechanical Drop Operational after 50 drops from 6 feet (1.83m) to concrete at 23°C Vibration Withstands 5G peak from 22 to 300 Hz ESD Tolerance Up to 15kV direct air Up to 8 kV indirect coupling plane 12 - 1 1902 Scanner Product Specifications Parameter Specification Dimensions (Typical): Height 6.3 inches (16 cm) Length 4.1 inches (10.41cm) Width 2.8 inches (7.11cm) Weight 7.5 ounces (212.62g) Illumination: Scan and Aiming LEDs LED output power 617nm + 18nm .339mW Image Size 838 x 640 pixels Skew Angle +65° Pitch Angle +45° Motion Tolerance: Streaming Presentation Trigger up to 240 inches per second for 13 mil UPC Symbol Contrast Grade 1.0 (20% or greater) Battery: Lithium Ion 1800 mAHr minimum Number of Scans Up to 50,000 per charge Expected Hours of Operation 14 Expected Charge Time 4.5 hours Radio: Frequency 2.4 to 2.5 GHz (ISM Band) Frequency Hopping Bluetooth v.2.1 Range 33 ft. (10 m) typical Data Rate Up to 1 MBps Temperature Ranges: Operating Storage* 32° F to +122° F (0° C to 50° C) -40°F to +158°F (-40°C to 70°C) Humidity Up to 95% non-condensing Mechanical Drop Operational after 50 drops from 6 feet (1.8 m) to concrete Vibration Withstands 5G peak from 22 to 300 Hz ESD Sensitivity Up to 15kV direct air Up to 8 kV indirect coupling plane Sealant Rating IP41 *Storage outside of this temperature range could be detrimental to battery life. 12 - 2 CCB01-010BT Charge Base Product Specifications Parameter Specification Dimensions (Typical): Height 3.2 inches (8.128cm) Length 5.19 inches (13.183cm) Width 3.98 inches (10.109cm) Weight 6.3 oz (179g) Voltage: 4.5 to 5.5 volts Current Draw: Host Terminal Port 500mA Aux Power Port 1A Charge Time 5 hours Radio: Frequency 2.4 to 2.5 GHz (ISM Band) Frequency Hopping Bluetooth v.2.1 Range 33 ft. (10 m) typical Data Rate Up to 1 MBps Temperature Ranges: Operating 32° F to +122° F (0° C to +50° C) Battery Charge 41° F to +104° F (5° C to +40° C) Storage -40° F to +158° F (-40° C to +70° C) Humidity Up to 95% non-condensing Mechanical Drop Operational after 50 drops from 3.28 feet (1 m) to concrete Vibration 5G Peak from 22Hz to 300Hz ESD Sensitivity Up to 15kV direct air Up to 8 kV indirect coupling plane 12 - 3 CCB01-010BT Charge Base Mounting 2.8 in. 72.1mm 3.35 in. 85.09mm 12 - 4 2.36 in. 59.84mm 8x32 thread x .39 in. (10mm) deep Cable shield Cable select Supply ground Terminal data Terminal clock Keyboard clock Supply power input +5V power Keyboard data Note: Pin assignments are not compatible with Honeywell legacy products. Use of a cable with improper pin assignments may lead to damage to the unit. Use of any cables not provided by the manufacturer may result in damage not covered by your warranty. 1 2 3 4 5 6 7 8 9 10 connects to the base 10 Pin RJ41 Modular Plug Standard Cable Pinouts Keyboard Wedge 12 - 5 12 - 6 Cable shield Cable select Supply ground Transmit data Receive data - serial data to scanner CTS +5V power RTS Note: Pin assignments are not compatible with Honeywell legacy products. Use of a cable with improper pin assignments may lead to damage to the unit. Use of any cables not provided by the manufacturer may result in damage not covered by your warranty. 1 2 3 4 5 6 7 8 9 10 connects to the base 10 Pin RJ41 Modular Plug Standard Cable Pinouts Serial Output +5V power Transmit Enable Cable shield Cable select Supply ground Transmit data Receive data - serial data to scanner Note: RS485 signal conversion is performed in the cable. Pin assignments are not compatible with Honeywell legacy products. Use of a cable with improper pin assignments may lead to damage to the unit. Use of any cables not provided by the manufacturer may result in damage not covered by your warranty. 1 2 3 4 5 6 7 8 9 10 connects to the base 10 Pin RJ41 Modular Plug Standard Cable Pinouts RS485 Output 12 - 7 12 - 8 Data + Data - +5V power Cable shield Cable select Supply ground Note: Pin assignments are not compatible with Honeywell legacy products. Use of a cable with improper pin assignments may lead to damage to the unit. Use of any cables not provided by the manufacturer may result in damage not covered by your warranty. connects to the base 10 Pin Modular Plug 1 2 3 4 5 6 7 8 9 10 Standard Cable Pinouts USB 13 Maintenance Repairs Repairs and/or upgrades are not to be performed on this product. These services are to be performed only by an authorized service center (see Customer Support on page 14-1). Maintenance Your device provides reliable and efficient operation with a minimum of care. Although specific maintenance is not required, the following periodic checks ensure dependable operation: Cleaning the Scanner The scanner or base’s housing may be cleaned with a soft cloth or tissue dampened with water (or a mild detergent-water solution.) If a detergent solution is used, rinse with a clean tissue dampened with water only. ! Caution: Do not submerge the scanner in water. The scanner’s housing is not watertight. Do not use abrasive wipes or tissues on the scanner’s window – abrasive wipes may scratch the window. Never use solvents (e.g., acetone) on the housing or window – solvents may damage the finish or the window. Cleaning the Window Reading performance may degrade if the scanner’s window is not clean. If the window is visibly dirty, or if the scanner isn’t operating well, clean the window with one of the cleaning solutions listed for Health Care Housing, below. Health Care Housing Some configurations of Xenon scanners are available with an external plastic housing that is designed to resist the effects of harsh chemicals in a health care environment. The plastic is crystalline in nature, which helps prevent chemicals from seeping through the housing. 13 - 1 Important! The following cleaning solutions have been tested to assure safe cleaning of your scanner’s disinfectant-ready housing. They are the only solutions approved for use with these scanners. Damage caused by the use of cleaners other than those listed below may not be covered by the warranty. • • • • • • • • • • Sani-Cloth® HB wipes Sani-Cloth® Plus wipes Super Sani-Cloth® wipes Isopropyl Alcohol wipes (70%) CaviWipes™ Virex® 256 409® Glass and Surface Cleaner Windex® Blue Clorox® Bleach – 10% Gentle dish soap and water Inspecting Cords and Connectors Inspect the interface cable and connector for wear or other signs of damage. A badly worn cable or damaged connector may interfere with scanner operation. Contact your distributor for information about cable replacement. Cable replacement instructions are on page 13-2. Replacing Cables in Corded Scanners The standard interface cable is attached to the scanner with an 10-pin modular connector. When properly seated, the connector is held in the scanner’s handle by a flexible retention tab. The interface cable is designed to be field replaceable. • Order replacement cables from Honeywell or from an authorized distributor. • When ordering a replacement cable, specify the cable part number of the original interface cable. 13 - 2 Replacing an Interface Cable 1. Turn the power to the host system OFF. 2. Disconnect the scanner’s cable from the terminal or computer. 3. Locate the small hole on the back of the scanner’s handle. This is the cable release. 4. Straighten one end of a paper clip. 5. Insert the end of the paper clip into the small hole and press in. This depresses the retention tab, releasing the connector. Pull the connector out while maintaining pressure on the paper clip, then remove the paper clip. Cable Release 6. Replace with the new cable. Insert the connector into the opening and press firmly. The connector is keyed to go in only one way, and will click into place. Replacing Cables and Batteries in Cordless Systems Replacing an Interface Cable in a Base 1. Turn the power to the host system OFF. 2. Disconnect the base’s cable from the terminal or computer. 3. Turn the base upside down. 4. Pull the connector out while maintaining pressure on the connector release clip. 5. Replace with the new cable. Insert the connector into the opening and press firmly. The connector is keyed to go in only one way, and will click into place. 13 - 3 Changing a scanner Battery 1. Loosen the thumb wheel screw on the end cap by hand or use a hex wrench. 2. Remove the battery from the handle. 3. Insert replacement battery. 4. Replace end cap and screw. Troubleshooting a Xenon Scanner End Cap The scanner automatically performs self-tests whenever you turn it on. If your scanner is not functioning properly, review the following Troubleshooting Guide to try to isolate the problem. Is the power on? Is the aiming beam on? If the aiming beam isn’t illuminated, check that: • The cable is connected properly. • The host system power is on (if external power isn’t used). • The trigger works. Is the scanner having trouble reading your symbols? If the scanner isn’t reading symbols well, check that the symbols: • Aren’t smeared, rough, scratched, or exhibiting voids. • Aren’t coated with frost or water droplets on the surface. • Are enabled in the scanner or in the decoder to which the scanner connects. Is the bar code displayed but not entered? The bar code is displayed on the host device correctly, but you still have to press a key to enter it (the Enter/Return key or the Tab key, for example). • You need to program a suffix. Programming a suffix enables the scanner to output the bar code data plus the key you need (such as “CR”) to enter the data into your application. Refer to Prefix/Suffix Overview on page 5-1 for further information. Does the scanner read the bar code incorrectly? If the scanner reads a bar code, but the data is not displayed correctly on the host screen: 13 - 4 • The scanner may not be programmed for the appropriate terminal interface. For example, you scan “12345” and the host displays “@es%.” Reprogram the scanner with the correct Plug and Play bar code. See Programming the Interface beginning on page 2-1. • The scanner may not be programmed to output your bar code data properly. For example, you scan “12345” and the host displays “A12345B.” Reprogram the scanner with the proper symbology selections. See Chapter 7. The scanner won’t read your bar code at all. 1. Scan the sample bar codes in the back of this manual. If the scanner reads the sample bar codes, check that your bar code is readable. Verify that your bar code symbology is enabled (see Chapter 7). 2. If the scanner still can’t read the sample bar codes, scan All Symbologies On, page 7-2. If you aren’t sure what programming options have been set in the scanner, or if you want the factory default settings restored, refer to Resetting the Factory Defaults on page 1-10. Troubleshooting a Cordless System Troubleshooting a Base Note: Visit the Services and Support section of our website (www.honeywellaidc.com) to check for the latest software for both the scanner and the base. If your base is not functioning properly, review the following troubleshooting guidelines to try to isolate the problem. Is the red LED on? If the red LED isn’t illuminated, check that: • The power cable is connected properly and there is power at the power source. • The host system power is on (if external power isn’t used). Is the green LED on? If the green LED isn’t illuminated, check that: • The scanner is correctly placed in the base. • There is external power or 12 volt host power. • Charge mode is turned on. (See "Beeper and LED Sequences and Meaning" on page 3-6) • The battery is not bad or deeply discharged. In some cases, the scanner’s battery may trickle charge to bring it into an acceptable level and then transition to a normal charge cycle. 13 - 5 Troubleshooting a Cordless Scanner Note: Make sure that your scanner’s battery is charged. Visit the Services and Support section of our website (www.honeywellaidc.com) to check for the latest software for both the scanner and the base or Access Point. Is the scanner having trouble reading your symbols? If the scanner isn’t reading symbols well, check that the symbols: • Aren’t smeared, rough, scratched, or exhibiting voids. • Aren’t coated with frost or water droplets on the surface. • Are enabled in the base or Access Point to which the scanner connects. Is the bar code displayed but not entered into the application? The bar code is displayed on the host device correctly, but you still have to press a key to enter it (the Enter/Return key or the Tab key, for example). • You need to program a suffix. Programming a suffix enables the scanner to output the bar code data plus the key you need (such as “CR”) to enter the data into your application. Refer to Prefix/Suffix Overview on page 5-1 for further information. Does the scanner read the bar code incorrectly? If the scanner reads a bar code, but the data is not displayed correctly on the host screen: • The base or Access Point may not be programmed for the appropriate terminal interface. For example, you scan “12345” and the host displays “@es%.” Reprogram the base/Access Point with the correct Plug and Play bar code. See Programming the Interface beginning on page 2-1. • The bas or Access Pointe may not be programmed to output your bar code data properly. For example, you scan “12345” and the host displays “A12345B.” Reprogram the base/Access Point with the proper symbology selections. See Chapter 7. The scanner won’t read your bar code at all. • Scan the sample bar codes in the back of this manual. If the scanner reads the sample bar codes, check that your bar code is readable. Verify that your bar code symbology is enabled (see Chapter 7). If the scanner still can’t read the sample bar codes, scan All Symbologies on page 7-2. 13 - 6 14 Customer Support Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the nearest technical support office: North America/Canada Telephone: (800) 782-4263 E-mail: hsmnasupport@honeywell.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 E-mail: hsmlasupport@honeywell.com Brazil Telephone: +55 (11) 5185-8222 Fax: +55 (11) 5185-8225 E-mail: brsuporte@honeywell.com Mexico Telephone: 01-800-HONEYWELL (01-800-466-3993) E-mail: soporte.hsm@honeywell.com Europe, Middle East, and Africa Telephone: +31 (0) 40 7999 393 Fax: +31 (0) 40 2425 672 E-mail: hsmeurosupport@honeywell.com Hong Kong Telephone: +852-29536436 Fax: +852-2511-3557 E-mail: aptechsupport@honeywell.com Singapore Telephone: +65-6842-7155 Fax: +65-6842-7166 E-mail: aptechsupport@honeywell.com China Telephone: +86 800 828 2803 Fax: +86-512-6762-2560 E-mail: aptechsupport@honeywell.com Japan Telephone: +81-3-6730-7344 Fax: +81-3-6730-7222 E-mail: aptechsupport@honeywell.com 14 - 1 Online Technical Assistance You can also access technical assistance online at www.honeywellaidc.com. Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, contact the appropriate location below to obtain a Return Material Authorization number (RMA #) before returning the product. North America Telephone: (800) 782-4263 E-mail: hsmnaservice@honeywell.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 Fax: (239) 263-9689 E-mail: laservice@honeywell.com Brazil Telephone: +55 (11) 5185-8222 Fax: +55 (11) 5185-8225 E-mail: brservice@honeywell.com Mexico Telephone: 01-800-HONEYWELL (01-800-466-3993) Fax: +52 (55) 5531-3672 E-mail: mxservice@honeywell.com Europe, Middle East, and Africa Telephone: +31 (0) 40 2901 633 Fax: +31 (0) 40 2901 631 E-mail: euroservice@honeywell.com Hong Kong Telephone: +852-29536436 Fax: +852-2511-3557 E-mail: apservice@honeywell.com Singapore Telephone: +65-6842-7155 Fax: +65-6842-7166 E-mail: apservice@honeywell.com China Telephone: +86 800 828 2803 Fax: +86-512-6762-2560 E-mail: apservice@honeywell.com 14 - 2 Japan Telephone: +81-3-6730-7344 Fax: +81-3-6730-7222 E-mail: apservice@honeywell.com Online Product Service and Repair Assistance You can also access product service and repair assistance online at www.honeywellaidc.com. Limited Warranty Honeywell International Inc. ("HII") warrants its products to be free from defects in materials and workmanship and to conform to HII’s published specifications applicable to the products purchased at the time of shipment. This warranty does not cover any HII product which is (i) improperly installed or used; (ii) damaged by accident or negligence, including failure to follow the proper maintenance, service, and cleaning schedule; or (iii) damaged as a result of (A) modification or alteration by the purchaser or other party, (B) excessive voltage or current supplied to or drawn from the interface connections, (C) static electricity or electro-static discharge, (D) operation under conditions beyond the specified operating parameters, or (E) repair or service of the product by anyone other than HII or its authorized representatives. This warranty shall extend from the time of shipment for the duration published by HII for the product at the time of purchase ("Warranty Period"). Any defective product must be returned (at purchaser’s expense) during the Warranty Period to HII factory or authorized service center for inspection. No product will be accepted by HII without a Return Materials Authorization, which may be obtained by contacting HII. In the event that the product is returned to HII or its authorized service center within the Warranty Period and HII determines to its satisfaction that the product is defective due to defects in materials or workmanship, HII, at its sole option, will either repair or replace the product without charge, except for return shipping to HII. EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW, THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR WARRANTIES, EITHER EXPRESSED OR IMPLIED, ORAL OR WRITTEN, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR NONINFRINGEMENT. HII’S RESPONSIBILITY AND PURCHASER’S EXCLUSIVE REMEDY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT WITH NEW OR REFURBISHED PARTS. IN NO EVENT SHALL HII BE LIABLE FOR INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, AND, IN NO EVENT, SHALL ANY LIABILITY OF HII ARISING IN CONNECTION WITH ANY PRODUCT SOLD HEREUNDER (WHETHER SUCH LIABILITY ARISES FROM A CLAIM BASED ON CONTRACT, WARRANTY, TORT, OR OTHERWISE) EXCEED THE ACTUAL AMOUNT PAID TO HII FOR THE PRODUCT. THESE LIMITATIONS ON LIABILITY SHALL REMAIN IN FULL FORCE AND EFFECT EVEN WHEN HII MAY 14 - 3 HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH INJURIES, LOSSES, OR DAMAGES. SOME STATES, PROVINCES, OR COUNTRIES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. All provisions of this Limited Warranty are separate and severable, which means that if any provision is held invalid and unenforceable, such determination shall not affect the validity of enforceability of the other provisions hereof. Use of any peripherals not provided by the manufacturer may result in damage not covered by this warranty. This includes but is not limited to: cables, power supplies, cradles, and docking stations. HII extends these warranties only to the first end-users of the products. These warranties are non-transferable. The duration of the limited warranty for the Xenon 1900 scanner is five (5) years. The duration of the limited warranty for the Xenon 1902 scanner and CCB01010BT Charge Base is three (3) years. The duration of the limited warranty for the Xenon battery is one (1) year. 14 - 4 A Reference Charts Symbology Chart Symbology AIM ID Possible AIM ID Modifiers ( m) All Symbologies Code ID (hex) (0x99) Australian Post ]X0 Aztec Code ]zm British Post ]X0 B (0x42) Canadian Post ]X0 C (0x43) China Post ]X0 Q (0x51) Chinese Sensible Code (Han Xin Code) ]X0 H (0x48) Codabar ]Fm 0-1 a (0x61) Codablock A ]O6 0, 1, 4, 5, 6 V (0x56) Codablock F ]Om 0, 1, 4, 5, 6 q (0x71) Code 11 ]H3 Code 128 ]Cm GS1-128 A (0x41) 0-9, A-C z (0x7A) h (0x68) 0, 1, 2, 4 j (0x6A) ]C1 I (0x49) Code 32 Pharmaceutical (PARAF) ]X0 < (0x3C) Code 39 (supports Full ASCII mode) ]Am 0, 1, 3, 4, 5, 7 b (0x62) Code 49 ]Tm 0, 1, 2, 4 l (0x6C) Code 93 and 93i ]Gm 0-9, A-Z, a-m i (0x69) Data Matrix ]dm 0-6 w (0x77) EAN-13 (including Bookland EAN) ]E0 d (0x64) EAN-13 with Add-On ]E3 d (0x64) EAN-13 with Extended Coupon Code ]E3 d (0x64) ]E4 D (0x44) ]E3 D (0x44) EAN-8 EAN-8 with Add-On A-1 Symbology AIM ID Possible AIM ID Modifiers ( m) GS1 Composite ]em 0-3 y (0x79) GS1 DataBar ]em 0 y (0x79) Code ID (hex) GS1 DataBar Limited ]em { (0x7B) GS1 DataBar Omnidirectional ]em y (0x79) GS1 DataBar Expanded ]em } (0x7D) InfoMail ]X0 , (0x2c) Intelligent Mail Bar Code ]X0 Interleaved 2 of 5 ]Im Japanese Post ]X0 J (0x4A) KIX (Netherlands) Post ]X0 K (0x4B) M (0x4D) 0, 1, 3 e (0x65) Korea Post ]X0 ? (0x3F) Matrix 2 of 5 ]X0 m (0x6D) MaxiCode ]Um 0-3 x (0x7 8) MicroPDF417 ]Lm 3-5 R (0x52) MSI ]Mm 0 NEC 2 of 5 ]X0 Y (0x59) OCR MICR (E 13 B) ]o3 O (0x4F) OCR SEMI Font ]o3 O (0x4F) OCR-A ]o1 O (0x4F) OCR-B ]o2 O (0x4F) PDF417 ]Lm Planet Code ]X0 0-2 g (0x67) r (0x72) L (0x4C) Postal-4i ]X0 N (0x4E) Postnet ]X0 P (0x50) QR Code and Micro QR Code ]Qm 0-6 s (0x73) Straight 2 of 5 IATA ]Rm 0, 1, 3 f (0x66) Straight 2 of 5 Industrial ]S0 f (0x66) TCIF Linked Code 39 (TLC39) ]L2 T (0x54) A-2 Possible AIM ID Modifiers (m) Code ID (hex) Symbology AIM ID Telepen ]Bm t (0x54) UPC-A ]E0 c (0x63) UPC-A with Add-On ]E3 c (0x63) UPC-A with Extended Coupon Code ]E3 c (0x63) ]E0 E (0x45) UPC-E UPC-E with Add-On ]E3 E (0x45) UPC-E1 ]X0 E (0x45) Note: “m” represents the AIM modifier character. Refer to International Technical Specification, Symbology Identifiers, for AIM modifier character details. Prefix/Suffix entries for specific symbologies override the universal (All Symbologies, 99) entry. Refer to Data Editing beginning on page 5-1 and Data Formatting beginning on page 6-1 for information about using Code ID and AIM ID. A-3 ASCII Conversion Chart (Code Page 1252) Note: This table applies to U.S. style keyboards. Certain characters may differ depending on your Country Code/PC regional settings. Non-Printable Characters DEC HEX Character (Code) 0 1 0 1 2 3 4 2 3 4 5 DEC HEX Character (Code) 16 17 10 11 DATA LINK ESCAPE (DLE) DEVICE CONTROL 1 (DC1) 18 19 20 12 13 14 DEVICE CONTROL 2 (DC2) DEVICE CONTROL 3 (DC3) DEVICE CONTROL 4 (DC4) 5 NULL START OF HEADING (SOH) START OF TEXT (STX) END OF TEXT (ETX) END OF TRANSMISSION (EOT) END OF QUERY (ENQ) 21 15 6 7 6 7 ACKNOWLEDGE (ACK) BEEP (BEL) 22 23 16 17 8 9 10 11 12 8 9 A B C BACKSPACE (BS) HORIZONTAL TAB (HT) LINE FEED (LF) VERTICAL TAB (VT) FF (FORM FEED) 24 25 26 27 28 18 19 1A 1B 1C 13 D CR (CARRIAGE RETURN) 29 1D 14 E SO (SHIFT OUT) 30 1E 15 F SI (SHIFT IN) 31 1F NEGATIVE ACKNOWLEDGEMENT (NAK) SYNCHRONIZE (SYN) END OF TRANSMISSION BLOCK (ETB) CANCEL (CAN) END OF MEDIUM (EM) SUBSTITUTE (SUB) ESCAPE (ESC) FILE SEPARATOR (FS) RIGHT ARROW GROUP SEPARATOR (GS) LEFT ARROW RECORD SEPARATOR (RS) UP ARROW UNIT SEPARATOR (US) DOWN ARROW DEC HEX Character 32 33 34 35 36 37 38 39 20 21 22 23 24 25 26 27 Printable Characters A-4 ! " # $ % & ' DEC HEX 64 65 66 67 68 69 70 71 40 41 42 43 44 45 46 47 Character @ A B C D E F G DEC 96 97 98 99 100 101 102 103 HEX 60 61 62 63 64 65 66 67 Character ` a b c d e f g Printable Characters (Continued) DEC HEX 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F Character ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ? DEC HEX 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F Character H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _ DEC HEX Character 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F h i j k l m n o p q r s t u v w x y z { | } ~ Extended ASCII Characters DEC HEX 128 129 130 131 132 133 134 135 136 137 138 139 80 81 82 83 84 85 86 87 88 89 8A 8B Character €€ ‚ ƒ „ … † ‡ ˆ ‰ Š ‹ DEC HEX 171 172 173 174 175 176 177 178 179 180 181 182 AB AC AD AE AF B0 B1 B2 B3 B4 B5 B6 Character « ¬ ® ¯ ° ± ² ³ ´ µ ¶ DEC HEX 214 215 216 217 218 219 220 221 222 223 224 225 D6 D7 D8 D9 DA DB DC DD DE DF E0 E1 Character Ö × Ø Ù Ú Û Ü Ý Þ ß à á A-5 Extended ASCII Characters (Continued) DEC HEX 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9E 9F A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA Character Œ Ž ‘ ’ “ ” • – — ˜ ™ š › œ ž Ÿ ¡ ¢ £ ¤ ¥ ¦ § ¨ © ª DEC HEX 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 B7 B8 B9 BA BB BC BD BE BF C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF D0 D1 D2 D3 D4 D5 Character · ¸ ¹ º » ¼ ½ ¾ ¿ À Á Â Ã Ä Å Æ Ç È É Ê Ë Ì Í Î Ï Ð Ñ Ò Ó Ô Õ DEC HEX 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC ED EE EF F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 FA FB FC FD FE FF Character â ã ä å æ ç è é ê ë ì í î ï ð ñ ò ó ô õ ö ÷ ø ù ú û ü ý þ ÿ Code Page Mapping of Printed Bar Codes Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the A-6 one the host program is expecting. If this is the case, select the code page with which the bar codes were created. The data characters should then appear properly. Code Page Standard Description 1 CP ISO646 2 (Default) ISO 2022 3 CP Binary 51 ISO 8859 1 51 Western European Replacement Characters 82 ISO 2022 11 Swe Swedish Replacement Characters 83 ISO 2022 69 Fra French/Belgium Replacement Characters 81 ISO 2022 25 Fra French/Belgium Replacement Characters 84 ISO 2022 11 Ger German Replacement Characters 85 ISO 2022 11 Ita Italian Replacement Characters 86 ISO 2022 11 Swi Swiss Replacement Characters 87 ISO 2022 11 UK British Replacement Characters 88 ISO 2022 11 Dan Danish Replacement Characters 89 ISO 2022 11 Nor Norwegian Replacement Characters 90 ISO 2022 11 Spa Spanish Replacement Characters 91 ISO 2022 85 Spanish Replacement Characters 92 ISO 2022 16 Portuguese Replacement Characters 93 ISO 2022 84 Portuguese Replacement Characters 94 ISO 2022 60 Norwegian Replacement Characters Automatic National Replacement Characters A-7 Unicode Key Maps 6E 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 2B 4B 50 55 4C 51 56 2C 2E 2F 30 31 32 33 34 35 36 37 39 3D 3A 3B 3C 3E 3F 38 40 53 4F 54 59 5A 5F 5B 60 5C 61 5D 62 63 64 69 65 6A 66 67 6C 68 5A 5F 5B 60 5C 61 5D 62 63 64 69 65 6A 66 67 6C 68 104 Key U.S. Style Keyboard 6E 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 2B 1E 1F 20 21 22 23 24 25 26 27 28 29 2A 4B 50 55 4C 51 56 2C 2D 2E 2F 30 31 32 33 34 35 36 37 39 3D 3A 3B 3C 3E 3F 38 40 53 4F 54 59 105 Key European Style Keyboard A-8 Sample Symbols UPC-A 0 123456 7890 Code 128 Code 128 Code 39 BC321 Code 93 123456-9$ Interleaved 2 of 5 1234567890 EAN-13 9 780330 290951 Codabar A13579B Straight 2 of 5 Industrial 123456 Sample Symbols Matrix 2 of 5 GS1 DataBar 6543210 PDF417 (01)00123456789012 Car Registration Postnet Zip Code Data Matrix QR Code Test Symbol Numbers 4-CB (4-State Customer Bar Code) 01,234,567094,987654321,01234567891 ID-tag (UPU 4-State) J18CUSA8E6N062315014880T Sample Symbols Aztec Micro PDF417 Package Label MaxiCode Test Message Test Message Programming Chart 0 1 2 3 4 5 6 7 8 9 Programming Chart A B C D E F Save Discard Reset Note: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Save again. Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 Xenon-UG Rev C 3/11
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res Author : Honeywell Scanning & Mobility Create Date : 2011:03:28 14:58:38Z Keywords : Xenon 1900, Xenon 1902, User’s Guide, Honeywell Modify Date : 2011:03:28 15:05:07-04:00 Subject : User’s Guide for Xenon 1900/1902 2D scanners and cordless base XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Description : User’s Guide for Xenon 1900/1902 2D scanners and cordless base Title : Xenon 1900/1902 Area-Imaging Scanner User’s Guide Creator : Honeywell Scanning & Mobility Producer : Acrobat Distiller 9.4.2 (Windows) Creator Tool : FrameMaker 9.0 Metadata Date : 2011:03:28 15:05:07-04:00 Document ID : uuid:25e4568f-7fcd-4c50-af9b-418e5468b024 Instance ID : uuid:254f09b1-4c16-4ae3-a117-3e1cbfeb6385 Page Mode : UseOutlines Page Count : 312EXIF Metadata provided by EXIF.tools