Honeywell TH6000R01 Programmable Thermostat User Manual 69 2427EFS 01 MRCH1 Remote Controller
Honeywell International Inc Programmable Thermostat 69 2427EFS 01 MRCH1 Remote Controller
Contents
- 1. Manual 1
- 2. Manual 2
Manual 1
Operating Manual Operating Manual MRCH1 Remote Controller 69-2427EFS-01 Quick Reference Card Battery Holder Press down and pull to remove batteries. Batteries should be replaced once a year (see page 28). Grasp and pull to see basic operating instructions at a glance. M28450A CAUTION: EQUIPMENT DAMAGE HAZARD. Please refer to the equipment Operating Manual for recommended operating temperatures. Need Help? For assistance with this product please visit http://controls.mehvac.com or call Mitsubishi Electric toll-free at 888-990-7546 Read and save these instructions. © 2010 Mitsubishi Electric & Electronics USA, Inc. Suwanee, GA 30024. Patents pending. All Rights Reserved. The three diamond logo is a registered trademark of Mitsubishi Electric Corporation www.mitsubishipro.com Français : voir la page 34 • Español: vea la página 68 Contents About your new remote controller Programming at a glance................... 2 Quick reference to controls............... 3 Quick reference to display screen..... 4 Appendices Advanced functions......................... 24 Battery replacement......................... 28 In case of difficulty........................... 31 Regulatory information..................... 32 Limited warranty............................... 33 Programming & Operation Set the time and day.......................... 5 Select the fan setting......................... 6 Select the system setting.................. 7 Multi-zone configurations.................. 8 Drying mode....................................... 9 Program schedules.......................... 10 Program schedule overrides............ 13 System changeover.......................... 17 Portable Central Controller.............. 18 Outdoor air sensor........................... 19 Additional features........................... 20 69-2427EFS—01 Operating Manual About your remote controller Your new remote controller is pre-programmed and ready to go. All you have to do is set the time and day. Then check the settings below and change if needed: 1. Set time and day (required for proper operation)........................... See page 5 2. Select fan setting.................................................................................. See page 6 3. Select system setting........................................................................... See page 7 4. Program schedules: Preset to energy-saving levels while space is occupied (assumes arrival at 8 am and departure at 10 pm)................................................................. See pages 10-11 ONE TOUCH TEMP CONTROL: You can override the program schedule at any time, and manually adjust the temperature (see pages 13-16). 69-2427EFS—01 Français : voir la page 34 • Español: vea la página 68 Quick reference to controls Digital display (see page 4) Temperature buttons Press to adjust temperature settings Battery holder (see page 28) M28451A Hold button Press to override programmed temperature control (see page 16) Function buttons Press to select the function displayed just above each button. (Functions change depending on the task.) 69-2427EFS—01 Operating Manual Quick reference to display screen Optimal Start (see page 23) Low battery warnings (see page 28) Current inside temperature Recovery ReplaceBattery Heat Indoor Setting Current program period occupied/unoccupied or Wake/Leave/Return/Sleep (see pages 10-11) Set Clock/Day/ Schedule (see pages 5 and 12) Current time (see page 5) AM occupied1 Set Clock/Day Schedule System Fan Auto Heat Locked More Locked (see page 23) More (see pages 20–23) M32209 Fan Setting Auto/On/Selectable (see page 6) System setting Cool/Heat/Drying/Auto/Off (see page 7) Note: Options may vary depending on your equipment. 69-2427EFS—01 Temperature setting (see pages 12–16) Français : voir la page 34 • Español: vea la página 68 Set the time and day Press SET CLOCK/DAY/SCHEDULE, then adjust time Set Clock/Day Schedule System Fan Auto More Heat M32218 1. Press SET CLOCK/DAY/SCHEDULE, then press s or t to set clock. 2. Press SET DAY, then press s or t to select the day of week. 3. Press DONE to save. Note: If the SET CLOCK/DAY/SCHEDULE option is not displayed, press DONE or CANCEL. Press SET DAY, then select current day Set Day Note: If the display flashes “Set Clock,” the remote controller will follow your settings for the weekday “occupied1” (or “Wake”) time period until you reset the time and day. Mo Set Day Done Set Schedule M32211 69-2427EFS—01 Operating Manual Select the fan setting Set Clock/Day Schedule Set Clock/Day Lo Schedule System Fan Auto Heat System Fan Hi Heat More Press FAN to select Auto or selectable fan speed. M32212 In “Auto” fan mode the equipment determines the optimal fan speed to meet the set temperature. More When system switch is “Off”, press FAN to circulate air. The fan will run at the user’s selected fan speed. M32213 Note: Selectable fan speed options may vary depending on your equipment. 69-2427EFS—01 Français : voir la page 34 • Español: vea la página 68 Select the system setting Set Clock/Day Schedule Fan Auto System Fan Auto System Fan Auto System Cool More M32214 Set Clock/Day Schedule Heat Press SYSTEM to select: • Cool: Remote controller controls only in the cooling mode. • Heat: Remote controller controls only in the heating mode. More • Drying: Remote controller directs indoor unit to remove moisture out of the air. May result in temperatures below your cool setting. M32215 Set Clock/Day Schedule More Drying M32300 Set Clock/Day Schedule Fan Auto System Auto • Auto: Remote controller automatically selects heating or cooling depending on the indoor temperature. More • Off: Indoor unit is off. M32301 Note: Options may vary depending on your equipment. 69-2427EFS—01 Operating Manual Multi-zone configurations Indoor Heat Setting Wait AM occupied1 Set Clock/Day Schedule Fan Auto System Heat More In multi-zone configurations, each zone is typically set to the same mode (Cool, Heat, or Drying). If zones are set to different modes, the first indoor unit to call for heat or cool will take priority. Other zones go into standby, and “Wait” will be displayed on the screen. M28946 69-2427EFS—01 Français : voir la page 34 • Español: vea la página 68 Drying mode (if configured) Set Clock/Day Schedule Fan Auto System More Drying M28947 Drying mode removes moisture from the air and works differently depending on the type of equipment installed. The temperature setting might or might not be displayed. The indoor unit will determine the Drying mode temperature setting. The setting will be either: • the cool temperature setting, or • 3°F (2°C) below room temperature. 69-2427EFS—01 Operating Manual Commercial program default settings This remote controller is pre-set to use energy saving program settings. We recommend these settings, since they can reduce your heating/cooling expenses. (See page 12 to adjust times and temperatures of each time period.) occupied1 (8:00 am) unoccupied1 (10:00 pm) occupied 2 unoccupied 2 Heat (Mon-Fri) Cool (Mon-Fri) Heat (Sat-Sun) Cool (Sat-Sun) 70 ° 55 ° --- 75 ° 85 ° --- 70 ° 55 ° --- 75 ° 85 ° --- occupied 2 and unoccupied 2 periods may be programmed as needed, depending on installed configuration. 69-2427EFS—01 10 Français : voir la page 34 • Español: vea la página 68 Residential program default settings This remote controller is pre-programmed to use commercial energy saving program settings. For use in a home, change the program to match your schedule. (See page 12 to adjust times and temperatures of each time period.) Wake (8:00 am) Leave (10:00 pm) Return Sleep Heat (Mon-Fri) Cool (Mon-Fri) Heat (Sat-Sun) Cool (Sat-Sun) 70 ° 55 ° --- 75 ° 85 ° --- 70 ° 55 ° --- 75 ° 85 ° --- (or cancel period) (or cancel period) May cancel Leave, Return and Sleep periods. 11 69-2427EFS—01 Operating Manual To adjust program schedules Set Clock/Day Schedule Fan Auto System Heat More M32218 Set Day Done Set Schedule M32219 1. Press SET CLOCK/DAY/SCHEDULE, then SET SCHEDULE. 2. Press s or t to set your weekday occupied1/Wake time (Mon–Fri), then press NEXT. 3. Press s or t to set the heat temperature for this time period, then press NEXT. 4. Press s or t to set the cool temperature for this time period, then press NEXT. 5. Set time and temperature for the next time period (unoccupied1/Leave). Repeat steps 4 and 5 for each weekday time period. 6. Press NEXT to set weekend time periods (SatSun), then press DONE to save & exit. Note: You may cancel a period using the CANCEL PERIOD button. If configured, you may power the system completely off during the period by using the POWER OFF PERIOD button. 69-2427EFS—01 12 Français : voir la page 34 • Español: vea la página 68 Schedule override (commercial only) Press to temporarily adjust temperature. Indoor 75 Indoor Cancel Cancel Hold Hold Until 6:00 PM Fan Fan Auto Auto PM If a person is present during an unoccupied period, press HOLD to temporarily use occupied temperature. Each additional press of HOLD extends the HOLD UNTIL duration by 1 hour to a limit set by the installer. Heat Cool Setting Setting 75 System System Auto Heat Press to resume program schedule More More The timer will expire automatically or schedule may be manually resumed by pressing CANCEL. M32221 M28461 Note: Permanent hold not available on commercial configuration. 13 69-2427EFS—01 Operating Manual Holiday override (commercial only) If the building will be unoccupied for more than one day, you can use Holiday override to maintain an unoccupied temperature. Hold Until Days Press MORE until the Hold Until screen appears. Press s or t to set the number of days, then press NEXT. Done M28948 Hold Until Days Cool Setting The cool temperature setting can only be set higher and the heat temperature setting can only be set lower than the unoccupied program schedule. Select Done Reset Heat/Cool M28950 69-2427EFS—01 Press s or t to set the heat or cool temperature setting, then press DONE. To clear the Holiday override from the home screen, press CANCEL. 14 Français : voir la page 34 • Español: vea la página 68 Temporary hold (residential only) Press to temporarily adjust temperature. Indoor Hold Until Press s or t to immediately adjust the temperature. This will temporarily override the temperature setting for the current time period. Cool Setting PM Cancel Fan Auto System Auto The new temperature will be maintained only until the next programmed time period begins (see page 11). More To cancel the temporary setting at any time, press CANCEL. M32221 Press to resume program schedule Temperature will be maintained until the time shown 15 69-2427EFS—01 Operating Manual Permanent hold (residential only) Press to permanently adjust temperature. 75 Indoor Cancel Cancel Hold PM Fan Fan Auto Auto PM System System Auto Heat Setting 75 Hold 6:00 Press HOLD to permanently adjust the temperature. This will override the temperature settings for all time periods. Heat Cool Setting Indoor The HOLD feature turns off the program schedule and allows you to adjust the temperature manually, as needed. More More M32222 M28461 Press to resume program schedule 69-2427EFS—01 Temperature will be maintained until CANCEL button is pressed. 16 The system will maintain the set temperature until you manually change it or you press CANCEL to resume the program schedule. Français : voir la page 34 • Español: vea la página 68 System Changeover Set Clock/Day Schedule Fan Auto System Auto More M32217 Press until screen displays “Auto” System Changeover is a feature used in climates where both air conditioning and heating are often used on the same day. When the system is set to “Auto,” the remote controller automatically selects heating or cooling depending on the indoor temperature. Heat and cool settings must be at least 2 degrees apart, depending how your remote controller was configured. The remote controller will automatically adjust settings to maintain this 2 (or more) degree separation. Note: The “Auto” system setting may not appear, depending on how your remote controller was configured. 17 69-2427EFS—01 Operating Manual Portable Central Controller (optional) The optional Portable Central Controller can manage temperatures of multiple split-zoning systems from almost anywhere on the property. The Portable Central Controller also works with other RedLINK™ devices used with other types of heating and cooling equipment. One Portable Comfort Control can adjust up to 16 zones on a single property. Note: The remote controller may take up to 15 seconds to respond to commands entered at the Portable Central Controller. 69-2427EFS—01 18 Français : voir la page 34 • Español: vea la página 68 Outdoor air sensor (optional) The outdoor air sensor allows outdoor air temperature and humidity to be shown on your remote controller. The outdoor air sensor also works with other RedLINK™ devices used with other types of heating and cooling equipment. Only use AA lithium batteries for the outdoor air sensor. 19 69-2427EFS—01 Operating Manual Remote Controller additional features To display outdoor temperature and humidity If you have an outdoor air sensor, press MORE to display the current outdoor temperature and humidity. Press DONE to exit. Outdoor Outdoor Humidity More Done FindRemote M32302 To find a lost Portable Central Controller If you misplace a Portable Central Controller, press MORE, then FIND REMOTE. The Portable Central Controller will beep for two minutes to help you locate it. Press anywhere on the display screen of the Portable Central Controller to stop the beeping. 69-2427EFS—01 20 Français : voir la page 34 • Español: vea la página 68 Remote Controller additional features (continued) To set up/down airflow direction (vane control) Ceiling If you would like to manually set the airflow direction, press MORE, then s or t to select the desired position, “Auto” or “Oscillate.” Set Airflow Direction Floor Done M32305 Note: “Auto” position is determined by the system equipment to provide maximum efficiency and comfort. Top and bottom positions may change after 1 hour to prevent condensation. Note: Airflow direction positions may vary depending on your equipment. 21 69-2427EFS—01 Operating Manual Remote Controller additional features (continued) Set a timer to automatically power off the indoor unit (if configured) Press MORE until “Power Off At” is displayed. Press s or t to set the time at which you would like the unit to turn off. Press DONE to exit. Note: This is not a recurring timer. This timer can be set up to 24 hours in advance. Depending on how this feature was installed, the indoor unit will either: A) Stay turned Off indefinitely until the user changes the system mode. B) Stay turned Off until the next scheduled period Example: If a room will be unoccupied at 10:00 PM, press MORE until “Power Off At” appears. Press s until 10:00 PM. Press DONE to exit. Heat Setting Indoor Power Off at: To clear the “Power Off At” timer from the home screen, press CANCEL. Cancel Fan Auto PM System Auto More M32304 69-2427EFS—01 22 Français : voir la page 34 • Español: vea la página 68 Remote Controller additional features (continued) Optimal Start: This feature eliminates the guesswork when setting your schedule. It allows the remote controller to “learn” how long your Split-Zoning System takes to reach programmed temperature settings, so the temperature is reached at the time you set. Locked: To prevent tampering, features can be fully or partially locked. When a selected feature is locked, the word “Locked” is displayed on the screen for approximately 5 seconds. Reset Clean Filter: When Remote Controller is flashing “Clean Filter,” press More and then press Reset. See page 25 to change or remove filter timer. Clean Filter More Done Reset M28980 23 69-2427EFS—01 Operating Manual Advanced functions Press and hold the MORE button until the display changes. “WAIT” will be displayed for up to 40 seconds. Function Option Press s or t to change option (see pages 25-27). More Next M289872 Done Back M32303 Press DONE to save & exit. “WAIT” will be displayed for up to 30 seconds. 69-2427EFS—01 24 Press NEXT to display next function screen M28488A (see pages 25-27). Français : voir la page 34 • Español: vea la página 68 Advanced functions Press s/t to change option, then press NEXT. Filter Change Reminder Function 107 Options: This feature displays an alert to remind you to change the filter in the indoor unit. 1 = 100 Hours 2 = 2500 Hours 3 = OFF (no reminder to change filter) Fahrenheit or Celsius Display Function 139 Options: Press s/t to change the display. 0 = Fahrenheit 1 = Celsius Schedule Format Function 148 Options: Press s/t to change the schedule format. 0 = 5-2 (Monday – Friday) (Sat-Sun) 1 = 5-1-1 (Monday – Friday) (Sat) (Sun) Optimal Start Function 150 Options: See page 23 for description of feature. 1 = ON 0 = OFF 25 69-2427EFS—01 Operating Manual Advanced functions Full Lockout Function 160 Options: This feature prevents users from changing all settings. 0 = No 1 = Yes Lockout On/Off Function 162 Options: This feature prevents users from changing the system setting to OFF. 0 = No 1 = Yes Lockout System Mode Function 164 Options: This feature prevents users from changing the system setting to Heat, Cool, Auto, Drying. 0 = No 1 = Yes Lockout Fan Mode Function 165 Options: This feature prevents users from changing the fan setting. 0 = No 1 = Yes 69-2427EFS—01 26 Français : voir la page 34 • Español: vea la página 68 Advanced functions Lockout Temperature Setting Function 166 Options: This feature prevents users from changing the temperature setting. 0 = No 1 = Yes Lockout Set Clock/Day/Schedule Function 168 Options: This feature prevents users from changing the clock, current day and the schedule. 0 = No 1 = Yes Maximum Heat Temperature Setting Allowed Function 170 Options: This feature prevents users from changing the Heat temperature setting above the selected temperature limit. Temperature setting range may vary based on equipment installed. 90 = 90°F (32°C) Temperature Limit 40-89 = 40 to 89°F (4.5 to 31.5°C) Minimum Cool Temperature Setting Allowed Function 172 Options: This feature prevents users from changing the Cool temperature setting below the selected temperature limit. Temperature setting range may vary based on equipment installed. 50 = 50°F (10°C) Temperature Limit 51-99 = 51 to 99°F (10.5 to 37°C) 27 69-2427EFS—01 Operating Manual Battery replacement (remote controller) Press down and pull to remove. Install fresh batteries when the “REPLACE BATTERY” warning begins flashing. The warning flashes about two months before the batteries are depleted. Replace Battery Remove the battery holder and install 2 fresh AA alkaline batteries. Do not use rechargeable batteries. M28466A Insert fresh AA alkaline batteries, then reinstall battery holder. After batteries are installed, the remote controller will automatically restore communication with the wireless network within a few minutes. Note: If batteries are inserted within 2 minutes, the time and day will not have to be reset. All other settings are retained in memory. 69-2427EFS—01 M28442 28 Français : voir la page 34 • Español: vea la página 68 Battery replacement (Portable Central Controller) Install fresh batteries when the “REPLACE BATTERY” warning begins flashing. The warning flashes about two months before the batteries are depleted. Remove the battery cover and install 3 fresh AA alkaline batteries. Do not use rechargeable batteries. After batteries are installed, the Portable Central Controller will automatically restore communication with the wireless network within a few minutes. M28475 29 69-2427EFS—01 Operating Manual Battery replacement (outdoor air sensor) Remove sensor from bracket Replace outdoor sensor batteries when the “Replace Battery Outdoor” warning begins flashing on the remote controller. The warning flashes about two months before the batteries are depleted. Remove the sensor from the bracket, remove the cover and install 2 fresh AA lithium batteries. Do not use rechargeable batteries. After batteries are installed, the sensor will automatically restore communication with the wireless network within a few minutes. M28443A Remove cover and install 2 fresh AA lithium batteries 69-2427EFS—01 M28444 30 Français : voir la page 34 • Español: vea la página 68 In case of difficulty Indoor unit does not respond • • • Check circuit breaker and reset if necessary. Make sure power switch at equipment is on. Wait 5 minutes for the system to respond. Screen displays “No Signal” Remote contoller has lost radio contact with the wireless network (usually because of a power outage). To restore power: • Check circuit breaker and reset if necessary. • Make sure power switch at indoor unit is on. After power is restored, the remote controller will automatically restore wireless communication within a few minutes. Displayed indoor temperature is above/below temperature setting The system requires a minimum on time for component protection. Please wait up to 6 minutes. 31 69-2427EFS—01 Add new section. Operating Manual Regulatory information Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only operate using an antenna of type and maximum ( or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent istropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. FCC Compliance Statement (Part 15.19) (USA only) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. FCC Warning (Part 15.21) (USA only) Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC Interference Statement (Part 15.105 (b)) (USA only) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: 69-2427EFS—01 • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Wireless receiver, remote controller and outdoor sensor To comply with FCC and Industry Canada RF exposure limits for general population/ uncontrolled exposure, the antenna(s) used for these transmitters must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Portable Central Controller This portable transmitter with its antenna complies with FCC and Industry Canada RF exposure limits for general population/ uncontrolled exposure. This device must not be co-located or operating in conjunction with any other antenna or transmitter. Section 7.1.5 of RSS-GEN Operation is subject to the following two conditions: 32 this device may not cause interference, and this device must accept any interference, including interference that may cause undesired operation of the device. Update to "7.1.3" Français : voir la page 34 • Español: vea la página 68 Limited warranty Refer to warranty statement in equipment documentation. 33 69-2427EFS—01 Aide-mémoire Support des piles Tirer sur la carte pour voir les instructions de base en un coup d’œil. Appuyer et tirer sur le support pour retirer les piles. Les piles doivent être remplacées une fois par an (voir page 62). M28450A MISE EN GARDE : RISQUE DE DOMMAGES DE L’ÉQUIPEMENT. Merci de consulter le manuel d’utilisation de l’équipement pour les températures de service recommandées. Besoin d’aide? Pour obtenir de l’aide avec ce produit, merci de visiter http://controls.mehvac.com ou d’appeler Mitsubishi Electric au numéro gratuit 888-990-7546 Lire et conserver ces instructions. © 2010 Mitsubishi Electric & Electronics USA, Inc. Suwanee, GA 30024. Brevets en instance. Tous droits réservés. Le logo à trois losanges est une marque déposée de Mitsubishi Electric Corporation www.mitsubishipro.com English: see page 1 • Español: vea la página 68 Contenu Dérogations au programme............. 47 Commutation du système................ 51 Régulateur central portatif............... 52 Capteur d’air extérieur..................... 53 Caractéristiques supplémentaires... 54 À propos de votre nouveau régulateur à distance Visualisation de la programmation... 36 Référence rapide des commandes............................... 37 Référence rapide de l’écran d’affichage........................................ 38 Annexes Fonctions évoluées.......................... 58 Remplacement des piles.................. 62 En cas de problème......................... 65 Informations réglementaires............ 66 Garantie limitée................................. 67 Programmation et fonctionnement Régler l’heure et le jour.................... 39 Sélectionner le réglage du ventilateur.................................... 40 Sélectionner le mode du système... 41 Configurations multizones............... 42 Mode de séchage............................. 43 Programmes..................................... 44 35 69-2427EFS—01 Mode d’emploi À propos du régulateur à distance Le nouveau régulateur à distance est préprogrammé et prêt à être utilisé. Il suffit de régler le jour et l’heure. Vérifier ensuite les réglages ci-dessous et les modifier si nécessaire : 1. Régler le jour et l’heure (requis pour un fonctionnement correct)...................................... Voir page 39 2. Sélectionner le réglage du ventilateur .......................................... Voir page 40 3. Sélectionner le mode du système................................................... Voir page 41 4. Programmes : Préréglés aux niveaux d’économie d’énergie lorsque l’espace est occupé (en supposant une arrivée à 8 h et un départ à 22 h).......................................... Voir pages 44-45 COMMANDE DE TEMPÉRATURE PAR SIMPLE PRESSION : Il est possible de déroger au programme à tout moment et de régler manuellement la température (voir pages 47-50). 69-2427EFS—01 36 English: see page 1 • Español: vea la página 68 Référence rapide des commandes Affichage numérique (voir p. 38) Boutons de température Appuyer sur ces boutons pour régler la température Support des piles (voir page 62) M28451A Boutons de fonction Appuyer pour sélectionner la fonction affichée juste au-dessus de chaque bouton. (Les fonctions changent en fonction de la tâche.) 37 Bouton de maintien (Hold) Appuyer pour déroger à la commande de température programmée (voir page 50). 69-2427EFS—01 Mode d’emploi Référence rapide de l’écran d’affichage Démarrage optimal (voir page 57) Avertissements de piles faibles (voir page 62) Température intérieure courante Recovery ReplaceBattery Heat Indoor Setting Période du programme en cours occupé/inoccupé/réveil/ départ/retour/sommeil (voir pages 44-45) Régler l’heure/le jour/le programme (voir pages 39 and 46) AM occupied1 Set Clock/Day Schedule System Fan Auto Heat Locked More Heure courante (voir page 39) Réglage de la température (voir pages 46–50) Verrouillé (voir page 57) Plus (More) (voir pages 54–57) M32209 Réglage du ventilateur Auto/Marche/Sélectionnable (voir page 40) Mode du système Refroidissement/Chauffage/Séchage/ Auto/Arrêt (voir page 41) Remarque : Les options peuvent varier en fonction de l’équipement 69-2427EFS—01 38 English: see page 1 • Español: vea la página 68 Régler l’heure et le jour Appuyer sur SET CLOCK/DAY/SCHEDULE (Régler heure/jour/ calendrier), puis régler l’heure. Set Clock/Day Schedule Fan Auto System Heat 2. Appuyer sur SET DAY puis appuyer sur s ou t pour choisir le jour de la semaine More 3. Appuyer sur DONE (Terminé) pour enregistrer les réglages. M32218 Appuyer sur SET DAY (Régler le jour), puis sélectionner le jour en cours. Set Day Done Set Schedule M32211 Remarque : Si l’option SET CLOCK/DAY/ SCHEDULE n’est pas affichée, appuyer sur DONE (Terminé) ou CANCEL (Annuler). Remarque : Si les mots Set Clock (Régler l’heure) clignotent à l’écran, le régulateur à distance respectera les réglages prévus pour la période « occupied1 » (occupé1) (ou « Wake » [Réveil]) jusqu’à ce que l’heure et le jour soient réglés. Mo Set Day 1. Appuyer sur SET CLOCK/DAY/SCHEDULE puis appuyer sur s ou t pour régler l’heure. 39 69-2427EFS—01 Mode d’emploi Sélectionner le réglage du ventilateur Set Clock/Day Schedule System Fan Auto Heat More M32212 Set Clock/Day Lo Schedule System Fan Hi Heat More M32213 Remarque : Les options de vitesses de ventilateur sélectionnables peuvent varier en fonction de l’équipement. 69-2427EFS—01 Appuyer sur FAN (Ventilateur) pour sélectionner la vitesse automatique ou sélectionnable du ventilateur. En mode automatique, l’équipement détermine la vitesse optimale du ventilateur en fonction de la température réglée. Lorsque le système est sur Arrêt, appuyer sur FAN pour faire circuler l’air. Le ventilateur tourne à la vitesse sélectionnée par l’utilisateur. 40 English: see page 1 • Español: vea la página 68 Sélectionner le mode du système Set Clock/Day Schedule Fan Auto System Fan Auto System Fan Auto System Cool More M32214 Set Clock/Day Schedule Heat More M32215 Set Clock/Day Schedule More Drying M32300 Set Clock/Day Schedule Fan Auto System Auto More M32301 Remarque : Les options peuvent varier en fonction de l’équipement. Appuyer sur SYSTEM pour sélectionner : • Cool (Refroidissement) : Le régulateur à distance ne commande qu’en mode de refroidissement. • Heat (Chauffage) : Le régulateur à distance ne commande qu’en mode de chauffage. • Drying (Séchage) : Le régulateur à distance commande à l’unité intérieure de retirer l’humidité de l’air. Ceci peut entraîner des températures inférieures au réglage. • Auto(matique) : RC passe automatiquement du système de chauffage au système de refroidissement en fonction de la température à l’intérieur. • Off (Arrêt) : L’unité intérieure est arrêtée. 41 69-2427EFS—01 Mode d’emploi Configurations multizones Indoor Heat Setting Wait AM occupied1 Set Clock/Day Schedule Fan Auto System Heat More M28946 69-2427EFS—01 Dans les configurations multizones, chaque zone est généralement réglée sur le même mode (refroidissement, chauffage ou séchage). Si les zones sont réglées sur différents modes, l’unité intérieure appelant la première le chauffage ou le refroidissement a la priorité. Les autres zones se mettent en mode de veille et « Wait » (Attente) s’affiche sur l’écran. 42 English: see page 1 • Español: vea la página 68 Mode de séchage (si configuré) Set Clock/Day Schedule Fan Auto System More Drying M28947 Le mode de séchage permet de retirer l’humidité de l’air et fonctionne différemment en fonction du type d’équipement installé. Le réglage de température peut ou non être affiché. L’unité intérieure détermine le réglage de température du mode de séchage. Le réglage est soit : • le réglage de température de refroidissement, soit • 2 °C (3 °F) inférieur à la température ambiante. 43 69-2427EFS—01 Mode d’emploi Réglages par défaut du programme commercial Ce régulateur à distance est préréglé pour utiliser les réglages du programme d’économie d’énergie. Il est recommandé d’utiliser ces réglages, car ils peuvent réduire les coûts de chauffage et de refroidissement. (Voir page 46 pour régler l’heure et la température de chaque période.) occupied1/ occupé1 (08:00) unoccupied1/ inoccupé1 (22:00) occupied 2/ occupé 2 unoccupied 2/ inoccupé 2 Heat/Chauffage Cool/Refroidissement Heat/Chauffage Cool/Refroidissement (Sam.-Dim.) (Sam.-Dim.) (Lun.-Ven.) (Lun.-Ven.) 70 ° 55 ° --- 75 ° 85 ° --- 70 ° 55 ° --- 75 ° 85 ° --- Les périodes occupied 2 (occupé 2) et unoccupied 2 (inoccupé 2) peuvent être programmées selon le besoin, en fonction de la configuration installée. 69-2427EFS—01 44 English: see page 1 • Español: vea la página 68 Réglages par défaut du programme résidentiel Ce régulateur à distance est préréglé pour utiliser les réglages du programme d’économie d’énergie commercial. Pour une utilisation à domicile, changer le programme en fonction de l’emploi du temps. (Voir page 46 pour régler l’heure et la température de chaque période.) Heat/Chauffage Cool/Refroidissement Heat/Chauffage Cool/Refroidissement (Sam.-Dim.) (Sam.-Dim.) (Lun.-Ven.) (Lun.-Ven.) Wake/Réveil (08:00) Leave/Départ (22:00) Return/Retour Sleep/Coucher 70 ° 55 ° --- 75 ° 85 ° --- 70 ° 55 ° --- 75 ° 85 ° --- (ou annuler la période) (ou annuler la période) Les périodes de départ, retour et sommeil peuvent être annulées. 45 69-2427EFS—01 Mode d’emploi Pour régler le programme Set Clock/Day Schedule Fan Auto System Heat More M32218 Set Day Done Set Schedule M32219 Remarque : Une période peut être annulée en utilisant le bouton CANCEL PERIOD (Annuler la période). Si configuré pour cela, le système peut être complètement désactivé durant la période en utilisant le bouton POWER OFF PERIOD (Période désactivée). 69-2427EFS—01 1. Appuyer sur SET CLOCK/DAY/SCHEDULE, puis sur SET SCHEDULE. 2. Appuyer sur s ou t pour régler l’heure occupied1/Wake des jours de la semaine (Lun-Ven), puis appuyer ensuite sur NEXT. 3. Appuyer sur s ou t pour régler la température du chauffage pour cette période, puis appuyer sur NEXT. 4. Appuyer sur s ou t pour régler la température de refroidissement pour cette période, puis appuyer sur NEXT. 5. Régler la température et l’heure de la période suivante (unoccupied1/Leave). Répéter les étapes 4 et 5 pour chaque période des jours de la semaine. 6. Appuyer sur NEXT pour régler les périodes de la fin de semaine (Sam-Dim), puis appuyer sur DONE pour enregistrer le programme et quitter. 46 English: see page 1 • Español: vea la página 68 Dérogation au programme (commercial uniquement) Appuyer pour ajuster provisoirement la température. Indoor 75 Indoor Cancel Cancel Hold Hold Until 6:00 PM Fan Fan Auto Auto PM System System Auto Heat Si une personne est présente durant une période inoccupée, appuyer sur HOLD (Maintien) pour activer provisoirement la température de période occupée. Chaque pression supplémentaire sur HOLD en augmente la durée d’une heure jusqu’à une limite réglée par l’installateur. Heat Cool Setting Setting 75 More More M32221 Appuyer pour revenir au programme. M28461 La minuterie expire automatiquement ou le programme peut être manuellement repris en appuyant sur CANCEL. Remarque : Maintien permanent non disponible sur la configuration commerciale. 47 69-2427EFS—01 Mode d’emploi Dérogation pour les vacances (commercial uniquement) Si le bâtiment sera inoccupé pendant plus d’une journée, la fonction de dérogation pour les vacances peut être utilisée pour maintenir une température de zone inoccupée. Hold Until Days Appuyer sur MORE jusqu’à ce que l’écran Hold Until (Maintenir jusqu’à) s’affiche. Done M28948 Hold Until Days Cool Setting Select Done Reset Heat/Cool M28950 69-2427EFS—01 Appuyer sur s ou t pour régler le nombre de jours, puis appuyer sur NEXT. Appuyer sur s ou t pour régler la température de chauffage ou de refroidissement, puis appuyer sur DONE. Le réglage de la température de refroidissement ne peut être qu’augmenté et celui de la température de chauffage que réduit par rapport au programme inoccupé. Pour annuler la dérogation pour vacances de l’écran d’accueil, appuyer sur CANCEL. 48 English: see page 1 • Español: vea la página 68 Maintien provisoire (résidentiel uniquement) Appuyer pour ajuster provisoirement la température Indoor Hold Until Appuyer sur s ou t pour ajuster immédiatement la température. Cette fonction permet de déroger provisoirement à la température de consigne de la période en cours. Cool Setting PM Cancel Fan Auto System Auto La nouvelle température de consigne restera en vigueur jusqu’au début de la prochaine période seulement (voir page 45). More M32221 Appuyer pour revenir au programme Pour annuler cette dérogation, il suffit d’appuyer à n’importe quel moment sur CANCEL. La température est maintenue jusqu’à l’heure indiquée 49 69-2427EFS—01 Mode d’emploi Maintien permanent (résidentiel uniquement) Appuyer ici pour modifier la température en permanence. Indoor 75 Indoor Cancel Cancel Hold Heat Cool Setting 6:00 PM Fan Fan Auto Auto PM System System Auto Heat Setting 75 Hold La fonction de maintien HOLD met le programme hors service et permet d’ajuster la température manuellement, au besoin. More More M32222 M28461 Appuyer pour revenir au programme 69-2427EFS—01 Appuyer sur HOLD pour ajuster la température de façon permanente. Cette fonction permet de déroger à la température de consigne pour toutes les périodes. La température sera maintenue jusqu’à ce que le bouton CANCEL soit pressé. 50 Le système maintient la température réglée jusqu’à ce qu’elle soit manuellement modifiée ou que CANCEL soit pressé pour revenir au programme.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Has XFA : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Modify Date : 2011:02:16 16:46:12-06:00 Create Date : 2011:02:16 16:46:12-06:00 Metadata Date : 2011:02:16 16:46:12-06:00 Creator Tool : Adobe InDesign CS3 (5.0) Format : application/pdf Title : 69-2427EFS-01 - MRCH1 Remote Controller Description : Operating Manual Creator : Technical Communications Document ID : uuid:2a459573-6771-4aec-84d1-e97b165a1335 Instance ID : uuid:505a75e3-c639-4c6d-921f-bd91e21e457a Producer : Adobe PDF Library 8.0 Page Count : 52 Author : Technical Communications Subject : Operating ManualEXIF Metadata provided by EXIF.tools