The installer will have set the programmer to suit the installed system. If this is a Fully pumped system this will allow independent control of the Central heating and Hot water, however on a Gravity system the Central heating and Hot water are linked so that it is not possible to use the Central heating independently. This will allow only one common time setting for both Hot Water and Central Heating. CH US ANN ER EL IN PLU ST S RU H CT 27 IO XL N FULLY PUMPED OR GRAVITY SYSTEM Horstmann’s ChannelPlus H27XL - Two Channel Programmer Offers up to three programmed operating periods per day, seven days a week, with independent Boost and Advance control on Fully Pumped Systems. Can be used as a direct replacement for Horstmann 425 Diadem, Tiara and H527(Allowing for new programmer position). BATTERY The programmer is fitted with a non-rechargeable, long life battery, which will maintain the programmed time settings for a minimum of ten months with the supply disconnected. THIS SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT. During power interruptions the display will be blank, after 3 days the current time of day will be lost. If the programmer is not to be used for a long period of time, the switch on the rear of the unit should be returned to the BATTERY OFF position. These are both to prolong the battery life. The following are some of the easy to operate features:Flexible 7 Day Control 1 or 2 Hour Boost on each channel Independent timing on Hot Water and Heating Advance control gives instant On/Off override Up to 3 On/Off periods per channel in each 24 Hr operation. Programme options: Auto / All day / On constantly / Off SERVICE AND REPAIR This programmer is NOT user serviceable. Please do not dismantle the unit. In the unlikely event of a fault developing please refer to the RESETTING THE PROGRAMMER section of this user guide located on page 2. If this fails to resolve the problem please contact a local heating engineer or a qualified electrician. QUESTIONS AND ANSWERS 3 The display only reads bAt Turn the battery on.The switch on the rear of the unit must be in either the Fully Pumped or Gravity position. The unit display has become frozen This could be due to local electrical interference Using the RESET procedure may rectify the fault. The indicator neon fails to illuminate on Hot Water or Central Heating channel Using the RESET procedure may rectify the fault. If the problem persists the programmer will need replacing. 1 2 5 4 7 6 8 9 The indicator neon will illuminate but the pump and/or boiler fails to operate This may indicate a problem elsewhere in your system; E.g. A zone valve, etc. please contact a registered installer for advice. There is no display on the programmer Try the RESET procedure on page 2, if this fails to rectify the problem please have the mains supply checked 13 How do I know if the programmer is still under warranty The ChannelPlus XL range comes with a 5 year guarantee from the date of manufacture. This date is located on the rear of the unit, indicated by a month over a year 15 How is the programmer removed from the wall WARNING: The ChannelPlus programmer must only be removed from it’s backplate by either a qualified electrician or heating engineer; The programmer plugs in to a 9 pin backplate located on the rear of the unit and is secured using 2 screws located on the top surface of the unit. Undo these screws and pull forward and down in an arc motion 10 11 12 14 Email: sales@horstmann.co.uk Website: www.horstmann.co.uk Page 4 Horstmann Controls Limited Bristol BS4 1UP LEAFLET No P32621 ISSUE 3 HEATING WATER CLOCK 17 HOLIDAY Internal Slide Switch located under front cover PROG.RUN When setting the programme times, the This indicates that you have reached an existing set time period, you will be unable to setting ‘bounces’ by 10 minute periods set a new ON/OFF time unless there is an alteration to the existing timed period LCD DISPLAY FEATURES 1 Current TIME OF DAY 2 Day of Week Indicator 3 Switch time SETTING indicator 4 ADVANCE symbol 5 BOOST symbol 6 Current Hot water programme 7 Current Central heating programme 8 Next Central heating switch time 9 Next Hot water switch time 16 16 SET slider switch 17 SET Positions LED INDICATOR 10 Central heating ON indicator 11 Hot water ON indicator EASY TO USE PROGRAMME AND FEATURE BUTTONS 12 Central heating ADVANCE(ENTER) button 13 Hot water ADVANCE (PLUS) button 14 Central heating BOOST(COPY) button 15 Hot water BOOST (MINUS)button Both the Central heating and Hot water SELECT buttons are located under the front cover Page 1 RESETTING THE PROGRAMMER SPECIAL FEATURES Lower the front flap of the unit. On the Heating channel press the ADVANCE and SELECT buttons together then release the buttons and the programmer will return to the preset factory settings. RESET Electronic equipment can in some circumstances be affected by electrical interference. If the programmer’s display becomes frozen or scrambled; or if you wish to revert back to the default time settings please use the following procedure. ADVANCE BOOST The SET slide switch must be in the PROG.RUN position for the following instructions. The following actions work independently on either Hot Water or Central Heating. Press SELECT once. Programme goes from AUTO to ALL DAY Press SELECT again. Programme goes from ALL DAY to ON Press SELECT again. Programme goes from ON to OFF Press SELECT again. Programme goes from OFF to AUTO Channel will operate from first ON until last OFF period Channel will be continuously ON Channel will be continuously OFF Programmer will return to normal ON and OFF times SELECT FRONT COVER The normal working position for the SET switch is in the PROG.RUN position. In order to remind the user of this, the flap is unable to be closed with the switch in any other position. The simple instructions below are designed to help with the programming of the unit. All the following instructions require the front flap to be lowered. Please replace the flap when normal operation is required. SETTING DAY AND TIME OF DAY Move the SET switch to the CLOCK position. Use PLUS and MINUS buttons to adjust day MON Use PLUS and MINUS buttons to adjust time Press ENTER TUE 12:OOPM 10:00AM SUN ALL DAY ON UNTIL 8:30PM SUN AUTO ON UNTIL 10:30AM 10:00AM SUN AUTO ON UNTIL 10:30AM ON OFF BOOST FUNCTION Return SET switch to PROG.RUN position Press BOOST button once for 1 hour of Hot Water or Central Heating 10:00AM AUTO ON UNTIL 10:30AM SUN 10:00AM AUTO ON UNTIL 10:30AM AUTO ON UNTIL 10:30AM 1 or 2 hour temporary override Press BOOST button twice for 2 hours of Hot Water or Central Heating At any time during a BOOST period press BOOST again to return to normal programming SUN 10:00AM AUTO ON UNTIL 11:30AM BOOST 1 2 AUTO ON UNTIL 11:30AM 1:45PM On the ChannelPlus display - Boost 1 is Hot water extension 1 or 2 hour and Boost 2 is Heating extension 1 or 2 hours SET SETTING ADVANCE FUNCTION - Brings forward next on or off operation DEFAULT TIME SETTINGS The default factory settings are shown, however if you wish to change these proceed as instructed below. 1st ON 1st OFF 2nd ON 2nd OFF 3rd ON 3rd OFF MON-FRI 6:30 AM 8:30 AM 12:00 PM 12:00 PM 4:30 PM 10:30 PM SAT/SUN 7:30 AM 10:30 AM 12:00 PM 12:00 PM 5:00 PM 11:00 PM SETTING THE ON AND OFF TIMES Move SET switch to Central Heating or Hot Water position Press ENTER Use PLUS and MINUS buttons to adjust day Repeat this process for 2nd and 3rd settings Use PLUS and MINUS buttons to adjust the 1st ON time. Press ENTER If you require this programme on any other day of the week use the PLUS and MINUS buttons to select day and press COPY Press ENTER Programme the remaining days. SUN SETTING 1ST ON 6:30AM Page 2 OFF 8:30AM Should you encounter any problems, please refer to the Question and Answer section located on page 4. Press ADVANCE button once to move to the next ON/OFF time HOLIDAY FUNCTION Move SET switch to the HOLIDAY position Use the PLUS and MINUS buttons to adjust the 1st OFF time. To cancel the advance press the ADVANCE button again. This will return the unit to its normal programme - Allows system to be programmed for up to 32 days Use the PLUS button to enter the required number of nights (MAX OF 32 NIGHTS) Return SET switch to the PROG.RUN position 08 SETTING Whilst the HOLIDAY FUNCTION is in operation the system will remain OFF, the display will show the number of nights remaining. The HOLIDAY setting is an instant function and cannot be set in advance. The HOLIDAY FUNCTION can be cancelled at any time by pressing any of the SELECT buttons. Normal programme functions will resume at the first ON period after the pre-set number of nights has expired. Return SET switch to PROG.RUN position. INFORMATION AND ADVICE Programming ON/OFF times If a Heating or Hot water period is not required it can be cancelled by setting the ON and OFF settings to the same time. Example ON 10:00am OFF 10:00am Your programmer will prevent you from accidentally overlapping ON and OFF times. Example: If the 2nd ON time is set at 12:00pm and then you try and set the 1st OFF at 12:30 pm the OFF setting will ‘bounce’ by a 10 minute period until the 2nd ON time has been adjusted. Page 3
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res Author : Mperkins Create Date : 2005:01:21 10:41:03Z Modify Date : 2014:12:07 15:04:28+08:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Producer : Acrobat Distiller 5.0 (Windows) Metadata Date : 2014:12:07 15:04:28+08:00 Creator Tool : PScript5.dll Version 5.2 Format : application/pdf Creator : Mperkins Title : H27XL-U.qxd Document ID : uuid:32e71b39-6c41-5645-b8c3-44583db1c701 Instance ID : uuid:94ecfabb-e7b5-794f-8ae3-d0def46d9baf Page Count : 2EXIF Metadata provided by EXIF.tools