Horstmann Channelplus H27Xl Users Manual U

2014-12-11

: Horstmann Horstmann-Channelplus-H27Xl-Users-Manual-120175 horstmann-channelplus-h27xl-users-manual-120175 horstmann pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

CCHHAANNNNEELLPPLLUUSS HH2277XXLL
UUSSEERR IINNSSTTRRUUCCTTIIOONN
BBAATTTTEERRYY
SSEERRVVIICCEE AANNDD RREEPPAAIIRR
This programmer is NOT user serviceable. Please do not dismantle the unit.
In the unlikely event of a fault developing please refer to the RESETTING THE PROGRAMMER section of
this user guide located on page 2. If this fails to resolve the problem please contact a local heating
engineer or a qualified electrician.
QQUUEESSTTIIOONNSSAANNDDAANNSSWWEERRSS
The display only reads bAt
The unit display has become frozen
The indicator neon fails to illuminate on
Hot Water or Central Heating channel
The indicator neon will illuminate but
the pump and/or boiler fails to
operate
There is no display on the
programmer
How do I know if the programmer is
still under warranty
How is the programmer removed from
the wall
When setting the programme times, the
setting ‘bounces’ by 10 minute periods
Turn the battery on.The switch on the rear of the unit must be in either the Fully
Pumped or Gravity position.
This could be due to local electrical interference
Using the RESET procedure may rectify the fault.
Using the RESET procedure may rectify the fault. If the problem persists the programmer
will need replacing.
This may indicate a problem elsewhere in your system;
E.g. A zone valve, etc. please contact a registered installer for advice.
Try the RESET procedure on page 2, if this fails to rectify the problem please have the
mains supply checked
The ChannelPlus XL range comes with a 5 year guarantee from the date of manufacture.
This date is located on the rear of the unit, indicated by a month over a year
WWAARRNNIINNGG:: The ChannelPlus programmer must only be removed from it’s backplate by
either a qualified electrician or heating engineer; The programmer plugs in to a 9 pin
backplate located on the rear of the unit and is secured using 2 screws located on the
top surface of the unit. Undo these screws and pull forward and down in an arc motion
This indicates that you have reached an existing set time period, you will be unable to
set a new ON/OFF time unless there is an alteration to the existing timed period
LEAFLET No P32621
ISSUE 3
PPaaggee 44
TThhee ffoolllloowwiinngg aarree ssoommee ooff tthhee eeaassyy ttoo ooppeerraattee ffeeaattuurreess::--
FFlleexxiibbllee 77 DDaayy CCoonnttrrooll
11 oorr 22 HHoouurr BBoooosstt oonn eeaacchh cchhaannnneell
IInnddeeppeennddeenntt ttiimmiinngg oonn HHoott WWaatteerr aanndd HHeeaattiinngg
AAddvvaannccee ccoonnttrrooll ggiivveess iinnssttaanntt OOnn//OOffff oovveerrrriiddee
UUpp ttoo 33 OOnn//OOffff ppeerriiooddss ppeerr cchhaannnneell iinn eeaacchh 2244 HHrr ooppeerraattiioonn..
PPrrooggrraammmmee ooppttiioonnss:: AAuuttoo // AAllll ddaayy // OOnn ccoonnssttaannttllyy // OOffff
FFUULLLLYY PPUUMMPPEEDD OORR GGRRAAVVIITTYY SSYYSSTTEEMM
The installer will have set the programmer to suit the installed system. If this is a Fully pumped
system this will allow independent control of the Central heating and Hot water, however on a Gravity
system the Central heating and Hot water are linked so that it is not possible to use the Central
heating independently. This will allow only one common time setting for both Hot Water and Central
Heating.
The programmer is fitted with a non-rechargeable, long life battery, which will maintain the
programmed time settings for a minimum of ten months with the supply disconnected.
THIS SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT.
During power interruptions the display will be blank, after 3 days the current time of day will be lost.
If the programmer is not to be used for a long period of time, the switch on the rear of the unit
should be returned to the BATTERY OFF position. These are both to prolong the battery life.
16 SET slider switch
17 SET Positions
LLCCDD DDIISSPPLLAAYYFFEEAATTUURREESS
1 Current TIME OF DAY
2 Day of Week Indicator
3 Switch time SETTING indicator
4 ADVANCE symbol
5 BOOST symbol
6 Current Hot water programme
7 Current Central heating programme
8 Next Central heating switch time
9 Next Hot water switch time
1
6
54
3 2
8
7
9
10
12
11
14
13
15
PROG.RUN
HOLIDAY
CLOCK
WATER
HEATING
IInntteerrnnaall SSlliiddee SSwwiittcchh --
llooccaatteedd uunnddeerr ffrroonntt ccoovveerr
17
16
LLEEDD IINNDDIICCAATTOORR
10 Central heating ON indicator
11 Hot water ON indicator
EEAASSYY TTOOUUSSEE PPRROOGGRRAAMMMMEEAANNDDFFEEAATTUURREEBBUUTTTTOONNSS
12 Central heating ADVANCE(ENTER) button
13 Hot water ADVANCE (PLUS) button
14 Central heating BOOST(COPY) button
15 Hot water BOOST (MINUS)button
BBootthh tthhee CCeennttrraall hheeaattiinngg aanndd HHoott wwaatteerr SSEELLEECCTT
bbuuttttoonnss aarree llooccaatteedd uunnddeerr tthhee ffrroonntt ccoovveerrPPaaggee 11
HHoorrssttmmaannnnss CChhaannnneellPPlluuss HH2277XXLL -- TTwwoo CChhaannnneell PPrrooggrraammmmeerr Offers up
to three programmed operating periods per day, seven days a week,
with independent Boost and Advance control on Fully Pumped Systems.
Can be used as a direct replacement for Horstmann 425 Diadem, Tiara
and H527(Allowing for new programmer position).
Horstmann Controls Limited
Bristol
BS4 1UP
Email: sales@horstmann.co.uk
Website: www.horstmann.co.uk
TThhee ssiimmppllee iinnssttrruuccttiioonnss bbeellooww aarree ddeessiiggnneedd ttoo hheellpp wwiitthh tthhee pprrooggrraammmmiinngg ooff tthhee uunniitt.. AAllll tthhee ffoolllloowwiinngg
iinnssttrruuccttiioonnss rreeqquuiirree tthhee ffrroonntt ffllaapp ttoo bbee lloowweerreedd.. PPlleeaassee rreeppllaaccee tthhee ffllaapp wwhheenn nnoorrmmaall ooppeerraattiioonn iiss
rreeqquuiirreedd..
Electronic equipment can in some circumstances be affected by electrical interference. If the
programmer’s display becomes frozen or scrambled; or if you wish to revert back to the default time
settings please use the following procedure.
FFRROONNTT CCOOVVEERR
SSEETTTTIINNGG DDAAYY AANNDD TTIIMMEE OOFF DDAAYY
Should you encounter any problems, please refer to the
QQuueessttiioonn aanndd AAnnsswweerr section located on page 4.
The normal working position for the SET switch is in the PROG.RUN position. In order to remind the user
of this, the flap is unable to be closed with the switch in any other position.
RREESSEETTTTIINNGG TTHHEE PPRROOGGRRAAMMMMEERR
Press SELECT once.
Programme goes from
AUTO to ALL DAY
Press SELECT again.
Programme goes from
ALL DAY to ON
Press SELECT again.
Programme goes from
ON to OFF
Press SELECT again.
Programme goes from
OFF to AUTO
Channel will operate
from first ON until last
OFF period
Channel will be
continuously ON
Channel will be
continuously OFF
Programmer will return
to normal ON and OFF
times
BBOOOOSSTT FFUUNNCCTTIIOONN-- 11 oorr 22 hhoouurr tteemmppoorraarryy oovveerrrriiddee
Press BOOST button
once for 1 hour of
Hot Water or
Central Heating
Press BOOST button
twice for 2 hours of
Hot Water or
Central Heating
At any time during a BOOST
period press BOOST again to
return to normal programming
AADDVVAANNCCEE FFUUNNCCTTIIOONN-- BBrriinnggss ffoorrwwaarrdd nneexxtt oonn oorr ooffff ooppeerraattiioonn
Press ADVANCE button once
to move to the next
ON/OFF time
To cancel the advance press the ADVANCE
button again. This will return the unit to
its normal programme
HHOOLLIIDDAAYY FFUUNNCCTTIIOONN -- AAlllloowwss ssyysstteemm ttoo bbee pprrooggrraammmmeedd ffoorr uupp ttoo 3322 ddaayyss
Move SET switch to the
HOLIDAY position
Use the PLUS button to enter the
required number of nights
(MAX OF 32 NIGHTS)
Return SET switch to the
PROG.RUN position
Whilst the HOLIDAY FUNCTION is in operation the system will remain OFF, the display will show the
number of nights remaining. The HOLIDAY setting is an instant function and cannot be set in advance.
The HOLIDAY FUNCTION can be cancelled at any time by pressing any of the SELECT buttons. Normal
programme functions will resume at the first ON period after the pre-set number of nights has expired.
IINNFFOORRMMAATTIIOONN AANNDD AADDVVIICCEE
Programming ON/OFF times
If a Heating or Hot water period is not required it can be cancelled by setting the ON and OFF
settings to the same time. Example ON 10:00am OFF 10:00am
Your programmer will prevent you from accidentally overlapping ON and OFF times.
Example: If the 2nd ON time is set at 12:00pm and then you try and set the 1st OFF at 12:30 pm the
OFF setting will ‘bounce’ by a 10 minute period until the 2nd ON time has been adjusted.
08
SETTING
ADVANCE
SELECT
Lower the front flap of the unit. On the Heating channel press the
ADVANCE and SELECT buttons together then release the buttons and
the programmer will return to the preset factory settings.
PPaaggee 22
BOOST
PPaaggee 33
Move the SET
switch to the CLOCK
position.
Use PLUS and
MINUS buttons to
adjust time
Return SET switch to
PROG.RUN position
Use PLUS and
MINUS buttons to
adjust day
Press
ENTER
Move SET switch to
Central Heating
or Hot Water
position
Repeat this
process for 2nd
and 3rd settings
Return SET
switch to PROG.RUN
position.
Press
ENTER
Press
ENTER
Press
ENTER
SSEETTTTIINNGG TTHHEE OONN AANNDD OOFFFF TTIIMMEESS
The SET slide switch must be in the PROG.RUN position for the following instructions.
The following actions work independently on either Hot Water or Central Heating.
SSPPEECCIIAALL FFEEAATTUURREESS
SETTING SET
TUE
MON 12:OOPM 1:45PM
SETTING 1ST
ON OFF
6:30AM 8:30AM
SUN
Use PLUS
and MINUS
buttons to
adjust day
Use PLUS and
MINUS
buttons to adjust
the 1st ON time.
Use the PLUS
and MINUS
buttons to adjust
the 1st OFF time.
Programme the
remaining days.
If you require this
programme on any other
day of the week use the
PLUS and MINUS buttons to
select day and press COPY
ALL DAY
ON UNTIL
8:30PM ON OFF
SUN 10:00AM SUN SUN
SUN
AUTO
ON UNTIL
10:30AM
AUTO
ON UNTIL
10:30AM
AUTO
ON UNTIL
10:30AM
AUTO
ON UNTIL
10:30AM
AUTO
ON UNTIL
10:30AM
BOOST 1 2
AUTO
ON UNTIL
11:30AM
AUTO
ON UNTIL
11:30AM
SUN
10:00AM 10:00AM 10:00AM
10:00AM
MON-FRI
SAT/SUN
1st ON 1st OFF 2nd ON 2nd OFF 3rd ON 3rd OFF
6:30 AAMM8:30 AAMM12:00 PPMM12:00 PPMM4:30 PPMM10:30 PPMM
7:30 AAMM10:30 AAMM12:00 PPMM12:00 PPMM5:00 PPMM11:00 PPMM
DDEEFFAAUULLTT TTIIMMEE SSEETTTTIINNGGSS
The default factory settings
are shown, however if you
wish to change these
proceed as instructed below.
RESET
On the ChannelPlus display - Boost 1 is Hot water extension 1 or 2 hour and Boost 2 is Heating extension 1 or 2 hours

Navigation menu