Hp Client Virtualization With Vmware View And Thinapp Users Manual Utilities User Guide
2015-01-05
: Hp Hp-Client-Virtualization-With-Vmware-View-And-Vmware-Thinapp-Users-Manual-156034 hp-client-virtualization-with-vmware-view-and-vmware-thinapp-users-manual-156034 hp pdf
Open the PDF directly: View PDF .
Page Count: 19
Download | |
Open PDF In Browser | View PDF |
HP VMware Utilities User Guide VMware ESXi 5.0 U2 and 5.0 U3 for September 2013 HP Part Number: 670557-407 Published: September 2013 Edition: 9 © Copyright 2007, 2013 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. UNIX is a registered trademark of The Open Group. Acknowledgments Microsoft Windows is U.S. registered trademarks of Microsoft Corporation. UNIX is a registered trademark of The Open Group. Contents 1 Introduction...............................................................................................4 Installing offline bundles on an ESXi 5.0 and updates host using vSphere CLI 5.0 esxcli utility.............4 Prerequisites........................................................................................................................4 Installing offline bundles on an ESXi 5.0 and updates host using VMware vCenter Update Manager.................................................................................................................................4 HPONCFG utility......................................................................................................................5 HPONCFG command-line syntax...........................................................................................5 HPONCFG return codes.......................................................................................................6 HPONCFG command file contents.........................................................................................6 Obtaining an entire configuration..........................................................................................6 Obtaining a specific configuration.........................................................................................7 Setting a configuration.........................................................................................................8 HPONCFG command-line examples.......................................................................................8 HPBOOTCFG utility..................................................................................................................9 HPBOOTCFG command-line syntax........................................................................................9 HPBOOTCFG ESXCLI syntax..................................................................................................9 HPBOOTCFG return codes..................................................................................................10 HPBOOTCFG command-line examples..................................................................................10 HPSSACLI utility......................................................................................................................10 HPSSACLI command-line syntax...........................................................................................10 HPSSACLI ESXCLI syntax.....................................................................................................11 HPTESTEVENT utility................................................................................................................13 HPTESTEVENT command-line syntax.....................................................................................13 HPTESTEVENT ESXCLI syntax...............................................................................................14 HPTESTEVENT return codes.................................................................................................14 HPTESTEVENT command-line examples.................................................................................14 Generating an ADU report (diagnostics) from within HPSSACLI for ESXi 5.0 and updates.................14 2 Support and other resources......................................................................16 Contacting HP .......................................................................................................................16 Before you contact HP........................................................................................................16 HP contact information.......................................................................................................16 Subscription service............................................................................................................16 Documentation feedback....................................................................................................16 New and changed information in this edition ............................................................................17 Related information.................................................................................................................17 Documents........................................................................................................................17 Websites..........................................................................................................................17 Typographic conventions.........................................................................................................17 Index.........................................................................................................19 Contents 3 1 Introduction This section provides information about the utilities supported on VMware ESXi 5.0 and updates. The following utilities are supported on VMware ESXi 5.0 and updates host: • HPONCFG — Command line utility used for obtaining and setting ProLiant iLO configurations. • HPBOOTCFG — Command line utility used for configuring ProLiant server boot order. • HPSSACLI – Command line utility used for configuration and diagnostics of ProLiant server SmartArrays. • HPTESTEVENT – Command line utility used to request the HP Insight Management WBEM Providers generate the Informational Test Indication with ProviderName “HP Test” and EventID 1, and the CPQ SNMP test trap with OID 1.3.6.1.4.1.232.11.2.8.1.0.11003. Installing offline bundles on an ESXi 5.0 and updates host using vSphere CLI 5.0 esxcli utility This section provides information about installing the VMware ESXi 5.0 and updates offline bundles on the ESXi host. You can use the esxcli utility in conjunction with offline bundles or with a depot. Prerequisites Install VMware vSphere Command-Line Interface 5.0(vSphere CLI) on Microsoft Windows or Linux system. For information about importing or installing the vSphere CLI 5.0, see the VMware vSphere Command-Line Interface Installation and Reference Guide available at: http://pubs.vmware.com/vsphere-50/topic/com.vmware.vcli.ref.doc_50/vcli-right.html. To install the offline bundle on an ESXi host, perform the following steps: 1. Power off any virtual machines that are running on the host, and set the host into maintenance mode. 2. Transfer the bundle onto the ESXi host local path, or extract it onto an online depot. 3. Install the bundle on the ESXi host using any of the following command line: • Install remotely from client, with offline bundle available as online depot ~# esxcli -s-u root -p mypassword software vib install -d • Install remotely from client, with offline bundle available on ESXi host ~# esxcli -s -u root -p mypassword software vib install -d • Install from ESXi host, with offline bundle available on ESXi host ~# esxcli software vib install -d 4. After the bundle is installed, reboot the ESXi host to initialize the utilities. Installing offline bundles on an ESXi 5.0 and updates host using VMware vCenter Update Manager The offline bundle can also be installed from VMware vCenter Update Manager as a patch. For more information and detailed instructions, see the VMware vCenter Update Manager Administration Guide available at: http://pubs.vmware.com/vsphere-50/topic/com.vmware.vsphere.update_manager.doc_50/ GUID-F7191592-048B-40C7-A610-CFEE6A790AB0.html. 4 Introduction HPONCFG utility The HPONFCG utility only supports HP ProLiant 300/500/700/900 Server series, 100 Series Gen8 servers, and HP ProLiant BL Servers that are listed in the ESXi Server Support Matrix. To visit the ESXi Server Matrix page, go to www.hp.com/go/vmware and select Certified ProLiants under Tools/Resource section. HP offers support for the iLO 2, iLO 3 and iLO 4 features available on ProLiant servers with the HPONCFG utility. HPONCFG is an online configuration tool used to set up and reconfigure iLO 2, iLO3 and iLO 4 without requiring a reboot of the server operating system. The utility runs in a command-line mode and must be executed from an operating system command-line. Observe the following requirements before using HPONCFG: • The iLO 2, iLO 3 or iLO 4 Management Interface Driver must be loaded on the server. HPONCFG displays a warning if the driver is not installed. • HPONCFG requires minimum iLO 2, iLO 3 and iLO 4 firmware versions. To determine the minimum firmware version required, see the HP SmartStart Scripting Toolkit Linux and Windows Editions Support Matrix. For more information, see the Remote Management website:http://www.hp.com/servers/lights-out HPONCFG command-line syntax Use the following format at the command line: hponcfg -f filename [-l filename] [-v] [-m minFw] -g [-m minFw] -w filename [-m minFw] -r [-m minFw ] -h -? The HPONCFG utility can be accessed from the location: /opt/hp/tools. IMPORTANT: Because the-w argument does not capture certain types of information, such as the administrator password, data files created with HPONCFG using the-w argument cannot then be used as input files for HPONCFG, unless they are modified first. Table 1 hponcfg Command Line Arguments Argument Function -a, --all This argument captures complete Management Processor configuration to the file. This option should be used along with the "-w" option. -i --input This argument Get/Set Management Processor Configuration from the XML input received through the standard input stream. -s,--substitute This argument substitutes variables present in the input configuration file with the values specified in "namevaluepairs". -f, - -file=filename This argument sets the iLO 2, iLO 3 or iLO 4 configuration based on the information in the XML input file named filename. -l, - -log=filename This argument logs replies to the text log file named filename. -v, - -xmlverbose Writes all the responses from iLO 2, iLO 3 or iLO 4. -g, - -get_hostinfo This argument returns the host server name and serial number. -m, - -minfwlevel This argument indicates to HPONCFG the minimum firmware level that must be present in the management device to execute the RIBCL script. If the minimum level is not met, HPONCFG returns an error without performing any additional actions. -w, - -writeconfig=filename This argument writes the iLO 2, iLO 3 or iLO 4 configuration obtained from the device to the XML output file named filename. HPONCFG utility 5 Table 1 hponcfg Command Line Arguments (continued) Argument Function -r, - -reset This argument resets the iLO 2, iLO 3 or iLO 4 to factory defaults. -h, - -help, - -? These arguments display simple help messages. HPONCFG return codes This section provides description about the return code after running the command. Table 2 hponcfg return codes Value Meaning -1 ERROR: A general system error detected while running HPONCFG 0 Script succeeded. 1 Script failed 2 ERROR : Unable to shutdown the iLo Channel Interface 3 Firmware flash is in progress. Please wait for a while. 4 General error detected while checking firmware flash. 5 iLO Lights-Out functionality is Disabled. Please enable Lights-Out functionality before using this software. To Enable Lights-Out functionality: Set iLO Security Override Switch to ON and Use iLO ROM-based Setup Utility or iLO Browser interface to enable lights-out functionality. 7 You are not a root/superuser. Only root/superuser can access the utility. 9 ERROR: Please specify firmware level as numeric input 10 Could not get status of the Lights-Out Functionality 13 - 20 ERROR: Failed to capture the configuration If the script itself fails, errors are reported in the log file created by HPONCFG. HPONCFG command file contents The hponcfg command can be used to perform the following tasks: • Obtain an entire configuration • Obtain a specific configuration • Set a configuration Obtaining an entire configuration The hponcfg command can be used to obtain an entire configuration from an iLO 2, iLO 3 or iLO 4. In this case, the utility executes from the command line without specification of an input file. The name of the output file is given on the command line. For example: /opt/hp/tools # ./hponcfg -w config.xml In this example, the utility indicated that it obtained the data successfully and wrote it to the output file as requested. The following is a typical example of the contents of the output file: 6 Introduction For security reasons, the user passwords are not returned. Obtaining a specific configuration A specific configuration can be obtained using the appropriate XML input file. For example, here are the contents of a typical XML input file, get_global.xml:The XML commands are read from the input file get_global.xml and are processed by the device: /opt/hp/tools # ./hponcfg -f get_global.xml -l log.txt > output.txt HPONCFG utility 7 The requested information is returned in the log file, which, in this example, is named log.txt. The contents of the log file are shown below: Setting a configuration A specific configuration can be sent to the iLO 2, iLO 3 or iLO 4 by using the command format: /opt/hp/tools # ./hponcfg -f add_user.xml -l log.txt In this example, the input file has contents: The specified user will be added to the device. HPONCFG command-line examples This section provides sample examples to run the utility. Table 3 hponcfg command-line examples Command-line argument Description hponcfg -h This argument displays help information. hponcfg -g This argument returns the host server name and serial number. To view the command usage options, run the following command: /opt/hp/tools # ./hponcfg —h All options supported by the command are listed in the output. To get the host server name and serial number, run the following command: /opt/hp/tools # ./hponcfg —g The following output is displayed: Firmware Revision = 2.05 Device type = iLO 2 Driver name = hpilo Host Information: Server Name: localhost.americas.hpqcorp.net Server Number: 000000000 To set the minimum firmware level, run the following command: 8 Introduction /opt/hp/tools # ./hponcfg —m 2 The following output is displayed: Firmware Revision = 2.05 Device type = iLO 2 Driver name = hpilo HPBOOTCFG utility The hpbootcfg utility only supports HP ProLiant 300/500/700/900 Server series, 100 Series Gen8 servers, and HP ProLiant BL Servers that are listed in the ESXi Server Support Matrix. To visit the ESXi Server Matrix page, go to www.hp.com/go/vmware and select Certified ProLiants under Tools/Resource section. This utility allows an application to set the device for the next subsequent boot of the system. HPBOOTCFG command-line syntax Use the following format at the command line: hpbootcfg [-F -C -H -T] [-S -Q -R -P] [-r -d -n -b] Table 4 hpbootcfg Command Line Arguments Argument Function -D Sets default device as the boot option -F Sets Floppy Drive as the first boot device for the system boot -C Sets CD-ROM Drive as the first boot device for the system boot -H Sets Hard Drive as the first boot device for the system boot -T Sets Tape Drive as the first boot device for the system boot -S Sets system configuration utility as the boot device for the current boot -Q Sets quick configuration utility as the boot device for the current boot -R Sets ROM-Based Setup Utility (RBSU) as the boot device for the current boot -P Sets PXE client as the boot device for the current boot -r Sets remote configuration as the boot device for the current boot -d Sets remote dial out as the boot device for the current boot -n Sets remote network as the boot device for the current boot -b Bypasses F1 / F2 prompts HPBOOTCFG ESXCLI syntax The hpbootcfg utility is supported by the ESXCLI utility. To view the command usage options, run the following command: # esxcli hpbootcfg The following output is displayed: Usage: esxcli hpbootcfg {cmd} [cmd options] Available Commands: execute execute — hpbootcfg command with options parameter help — show hpbootcfg help show — show current hpbootcfg settings To view the current boot settings, run the following command: # esxcli hpbootcfg show HPBOOTCFG utility 9 The following output is displayed: 00 00: Normal Device first, normal boot process To set the command parameter values, use the "execute" cmd and one of the options listed in Table 4. The following is an example of the command to set the defaults: # esxcli hpbootcfg execute -D The following output is displayed: 00 00: Normal Device first, normal boot process HPBOOTCFG return codes This section provides description about the return code after running the command. Table 5 hpbootcfg return codes Value Meaning 0 Indicates success Non zero Indicates failure HPBOOTCFG command-line examples This section provides sample examples to run the utility. Table 6 hpbootcfg command-line examples Command-line argument Description /opt/hp/tools/hpbootcfg -h This argument displays help information. /opt/hp/tools/hpbootcfg -D This argument sets the default values. HPSSACLI utility The HPSSACLI utility supports HP ProLiant 300/500/700 and Blade servers with integrated SmartArray controllers and option controllers. The utility supports reporting and configuration of the SmartArray. Configuration includes the ability to create arrays; create, expand, and delete logical drives and many other advanced operations. The information provided in the guide is introductory and example focused . For more information, see Configuring Arrays on HP Smart Array Controllers Reference Guide available at:http://h20000.www2.hp.com/bc/docs/support/ SupportManual/c00729544/c00729544.pdf. Additional references to HP Smart Storage Administrator guides and white papers are available at: http://h20000.www2.hp.com/bizsupport/TechSupport/DocumentIndex.jsp?lang=en&cc=us& contentType=SupportManual&prodTypeId=18964&prodSeriesId=468780&docIndexId=64179. HPSSACLI command-line syntax Using VMware esxcli requires knowledge about the CLI usage. The VMware vSphere command line documentation is available at: http://www.vmware.com/support/developer/vcli/. The following is an overview of the ESXCLI command-line format: # esxcli {namespace} {object} {command} {cmd options} “command-string” 10 Introduction Table 7 HPSSACLI Command-Line Arguments Argument Function esxcli The esxcli application. namespace Each plugin must have an associated namespace which defines any environment or other system variables required by the application. object A plugin must have one or more associated objects which defines a single operation. command Prepares the esxcli target to accept a command-line string. cmd options Additional switches associated with the command itself (if necessary). “command-string” This is the string which dictates the operation that should be executed by the target application itself. The current namespace and command names are: hpssacli and cmd respectively. The {cmd options} parameter can be cmdopts or -q. There is no need for an {object} type for hpssacli since the application operates on internal commands supplied in the command-string. HPSSACLI ESXCLI syntax The HPSSACLI utility is supported by the ESXCLI utility. Use the following command syntax for all commands: # esxcli –server=”servername or IP” –user=”username” –password=”root password” hpssacli cmd -q “command-string” The command-string parameter supports same commands that are specified at the HPSSACLI interactive command-line interface. Example 1 This example shows the information about all the SmartArray controller on the server. esxcli –server=”servername or IP” –user=”username” –password=”root password” hpssacli cmd -q “controller all show status ” The following output is displayed: Smart Array P212 in Slot 9 Controller Status: OK Smart Array P410i in Slot 0 (Embedded) Controller Status: OK Cache Status: OK Battery/Capacitor Status: OK Example 2 This example shows the detailed configuration information for the SmartArray controller in slot 0. # esxcli –server=”servername or IP” –user=”username” –password”root password” hpssacli cmd -q “controller slot=0 show config detail” The following output is displayed: Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 5001438013A25C90 Cache Serial Number: PBCDF0CRH0J7SD RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: C HPSSACLI utility 11 Firmware Version: 3.70 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Queue Depth: Automatic Monitor and Performance Delay: 60 min Elevator Sort: Enabled Degraded Performance Optimization: Disabled Inconsistency Repair Policy: Disabled Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Accelerator Ratio: 25% Read / 75% Write Drive Write Cache: Disabled Total Cache Size: 1024 MB Total Cache Memory Available: 912 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Capacitors Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 0 MB Status: OK Logical Drive: 1 Size: 136.7 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 35132 Strip Size: 256 KB Full Stripe Size: 256 KB Status: OK Array Accelerator: Enabled Unique Identifier: 600508B1001CB65083D63C5E781ABF65 Disk Name: vmhba2:C0:T0:L1 Mount Points: None Logical Drive Label: A00D1AF35001438013A25C90F0BA Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) physicaldrive 1I:1:1 Port: 1I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 6SD3FJVL0000B145MFXB Model: HP EG0146FAWHU Current Temperature (C): 36 Maximum Temperature (C): 46 PHY Count: 2 PHY Transfer Rate: 6.0GBPS, Unknown 12 Introduction physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 6SD3EVBH0000B144Q7RD Model: HP EG0146FAWHU Current Temperature (C): 37 Maximum Temperature (C): 49 PHY Count: 2 PHY Transfer Rate: 6.0GBPS, Unknown unassigned physicaldrive 1I:1:3 Port: 1I Box: 1 Bay: 3 Status: OK Drive Type: Unassigned Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 6SD3FK4A0000B145J6JK Model: HP EG0146FAWHU Current Temperature (C): 37 Maximum Temperature (C): 48 PHY Count: 2 PHY Transfer Rate: 6.0GBPS, Unknown ... These examples are not inclusive of all the capabilities of the HPSSACLI command. Commands and options for additional operations using the HPSSACLI, such as creating a logical drive, are documented in the Configuring Arrays on HP Smart Array Controllers Reference Guide. HPTESTEVENT utility The hptestevent utility allows an application to request the HP Insight Management WBEM Providers generate the Informational Test Indication with ProviderName “HP Test” and EventID 1, and the CPQ SNMP test trap with OID 1.3.6.1.4.1.232.11.2.8.1.0.11003. The HP Insight Management WBEM Providers must be installed, enabled and running on the system where this utility is executed. The WBEM Providers must be configured to send indications to the listener. VMware SNMP traps must be enabled and configured to use WBEM indications as a source for SNMP traps. The Informational Test Indication and the CPQ Test SNMP trap will be sent to any listener configured to receive indications from the system. See the HP Insight Management WBEM Provider Datasheets for information on the test indication, and the SNMP Data Migration Guide for information on the test SNMP trap on the BSC (Business Support Center). HPTESTEVENT command-line syntax Use the following format at the command line: hptestevent HPTESTEVENT utility 13 There are no command options for the hptestevent utility. HPTESTEVENT ESXCLI syntax The hptestevent utility is supported by the ESXCLI utility. To view the command usage options, run the following command: # esxcli hptestevent The following output is displayed: Usage: esxcli hptestevent {cmd} [cmd options] Available Commands: execute execute the hptestevent command To request a test indication and test SNMP trap to be generated, run the following command: # esxcli hptestevent execute The following output is displayed: Request successful. Test event will be generated. HPTESTEVENT return codes This section provides description about the return code after running the command. Table 8 hptestevent return codes Value Meaning 0 Indicates success 1 Request failed. No test event will be generated. 2 Request failed, must be root. No test event will be generated. 3 Request failed, couldn't determine if HP WBEM Providers are installed and running. No test event will be generated. 4 Request failed, HP WBEM Providers are not installed and running. No test event will be generated. HPTESTEVENT command-line examples This section provides sample examples to run the utility. Table 9 hptestevent command-line examples Command-line Description /opt/hp/tools/hptestevent Run command directly on the ESXi host esxcli hptestevent execute Use esxcli to run the command Generating an ADU report (diagnostics) from within HPSSACLI for ESXi 5.0 and updates The HPSSACLI application contains the ability to generate a diagnostic report of the system and its Smart Array storage configuration. The following steps are required in order to obtain an ADU report from a remote machine running ESXi 5.0 and updates. 14 Introduction 1. Obtain and install the HP Smart Storage Administrator Diagnostics Utility (HP SSADU) CLI: 1. Browse to http://www.hp.com 2. Click on Support & Drivers 3. Select Drivers & Software 4. In the search box, type HP Smart Storage Administrator Utility 5. Select the operating system of the client machine that will be used to remotely access the machine running ESXi 5.0 and updates. 6. Under the Software – System Management menu, proceed to download the HP Smart Storage Administrator Diagnostics Utility (HP SSADU) CLI by clicking on the link. NOTE: 7. 2. 3. 4. The desired version is 9.x or newer. Install the Windows component or Linux RPM package onto the client machine. The location where the package has installed the included applications and then update your system path to include this location. The client machine used to access the remote ESXi 5.0 and updates machine must also have the vSphere CLI esxcli command line tool installed and must be accessible through the system path. Ensure that the client machine location is included in the path. Use the following tool and associated command-line parameters to perform the creation and retrieval of the report: hpssaduesxi --server= --user= --password= Example Usage: hpssaduesxi --server=10.12.132.5 --user=root --password=root.123 myreport.zip The hpssaduesxi application uses the supplied parameters to remotely obtain the report from your target ESXi 5.0 and updates machine and saves the data into the target zip file. The zip file can then be opened with any third-party zip application or with the unzip command under Linux. The hpssaduesxi application also contains onboard help which can be obtained by typing hpssaduesxi with no parameters. Generating an ADU report (diagnostics) from within HPSSACLI for ESXi 5.0 and updates 15 2 Support and other resources This chapter provides information about the contact details and reference documents. Contacting HP This section provides information about the prerequisites to be verified before contacting HP and mechanism supported by the organization for sharing the feedback. Before you contact HP Be sure to have the following information available before you call contact HP: • Technical support registration number (if applicable) • Product serial number • Product model name and number • Product identification number • Applicable error message • Add-on boards or hardware • Third-party hardware or software • Operating system type and revision level HP contact information For the name of the nearest HP authorized reseller: • See the Contact HP worldwide (in English) webpage (http://welcome.hp.com/country/us/ en/wwcontact.html). For HP technical support: • In the United States, for contact options see the Contact HP United States webpage (http:// welcome.hp.com/country/us/en/contact_us.html). To contact HP by phone: ◦ Call 1-800-HP-INVENT (1-800-474-6836). This service is available 24 hours a day, 7 days a week. For continuous quality improvement, calls may be recorded or monitored. ◦ If you have purchased a Care Pack (service upgrade), call 1-800-633-3600. For more information about Care Packs, refer to the HP website (http://www.hp.com/hps). ◦ In other locations, see the Contact HP worldwide (in English) webpage (http:// welcome.hp.com/country/us/en/wwcontact.html). Subscription service HP recommends that you register your product at the Subscriber's Choice for Business website: http://www.hp.com/country/us/en/contact_us.html After registering, you will receive email notification of product enhancements, new driver versions, firmware updates, and other product resources. Documentation feedback HP welcomes your feedback. To make comments and suggestions about product documentation, send a message to docsfeedback@hp.com. Include the document title and manufacturing part number. All submissions become the property of HP. 16 Support and other resources New and changed information in this edition • Wording added for hponcfg and hpbootcfg to identify both tools support execution on ProLiant Series 100 Gen 8. • Additional arguments for hponcfg command line. Related information Following documents and websites provide related information: Documents Following documents are supported for the product: • HP VMware ESXi 5.0 Release Notes • HP VMware ESXi 5.0 and Updates Getting Started Guide Websites HP documents regarding VMware are available at the following location: https://h20392.www2.hp.com/portal/swdepot/searchProducts.do. Typographic conventions This document uses the following typographical conventions: %, $, or # A percent sign represents the C shell system prompt. A dollar sign represents the system prompt for the Bourne, Korn, and POSIX shells. A number sign represents the superuser prompt. audit(5) A manpage. The manpage name is audit, and it is located in Section 5. Command A command name or qualified command phrase. Computer output Text displayed by the computer. Ctrl+x A key sequence. A sequence such as Ctrl+x indicates that you must hold down the key labeled Ctrl while you press another key or mouse button. ENVIRONMENT VARIABLE The name of an environment variable, for example, PATH. ERROR NAME The name of an error, usually returned in the errno variable. Key The name of a keyboard key. Return and Enter both refer to the same key. Term The defined use of an important word or phrase. User input Commands and other text that you type. Variable The name of a placeholder in a command, function, or other syntax display that you replace with an actual value. [] The contents are optional in syntax. If the contents are a list separated by |, you must choose one of the items. {} The contents are required in syntax. If the contents are a list separated by |, you must choose one of the items. ... The preceding element can be repeated an arbitrary number of times. Indicates the continuation of a code example. | Separates items in a list of choices. New and changed information in this edition 17 18 WARNING A warning calls attention to important information that if not understood or followed will result in personal injury or nonrecoverable system problems. CAUTION A caution calls attention to important information that if not understood or followed will result in data loss, data corruption, or damage to hardware or software. IMPORTANT This alert provides essential information to explain a concept or to complete a task NOTE A note contains additional information to emphasize or supplement important points of the main text. Support and other resources Index D document related documentation, 17 R related documentation, 17 19
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Author : Hewlett-Packard Company Trapped : False Create Date : 2013:10:11 05:30:44Z Modify Date : 2013:10:11 05:30:44Z Page Count : 19 Page Mode : UseOutlines Format : application/pdf Title : HP VMware Utilities User Guide Creator : Hewlett-Packard Company Producer : XEP 4.18 build 20100322 Creator Tool : UnknownEXIF Metadata provided by EXIF.tools