Console Management Controller
User Guide

Second Edition (July 2001)
Part Number 218258-002
Compaq Computer Corporation

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: a-frnt.doc Last Saved On: 6/20/01 3:04 AM

Notice
© 2001 Compaq Computer Corporation

Compaq, Compaq Insight Manager and the Compaq logo Registered in U.S. Patent and Trademark
Office.
Microsoft and Windows are trademarks of Microsoft Corporation in the United States and other
countries.
Intel is a trademark of Intel Corporation in the United States and other countries.
Compaq shall not be liable for technical or editorial errors or omissions contained herein. The
information in this document is provided “as is” without warranty of any kind and is subject to change
without notice. The warranties for Compaq products are set forth in the express limited warranty
statements accompanying such products. Nothing herein should be construed as constituting an
additional warranty.
Compaq service tool software, including associated documentation, is the property of and contains
confidential technology of Compaq Computer Corporation. Service customer is hereby licensed to use
the software only for activities directly relating to the delivery of, and only during the term of, the
applicable services delivered by Compaq or its authorized service provider. Customer may not modify
or reverse engineer, remove, or transfer the software or make the software or any resultant diagnosis or
system management data available to other parties without Compaq’s or its service provider’s consent.
Upon termination of the services, customer will, at Compaq’s or its service provider’s option, destroy
or return the software and associated documentation in its possession.

Compaq Console Management Controller User Guide
Second Edition (July 2001)
Part Number 218258-002

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: a-frnt.doc Last Saved On: 6/20/01 3:04 AM

Contents

About This Guide
Text Conventions.......................................................................................................vii
Symbols in Text....................................................................................................... viii
Symbols on Equipment............................................................................................ viii
Rack Stability .............................................................................................................ix
Getting Help ................................................................................................................x
Compaq Technical Support ..................................................................................x
Compaq Website...................................................................................................x
Compaq Authorized Reseller................................................................................x

Chapter

1

Overview
Compaq Console Management Controller............................................................... 1-2
General Description ................................................................................................. 1-2
Standard CMC Features........................................................................................... 1-3
Communications Ports...................................................................................... 1-4
Compaq Intelligent Rack Manager Lite............................................................ 1-4
Front Panel............................................................................................................... 1-5
Front Panel Controls......................................................................................... 1-6
Front Panel LEDs ............................................................................................. 1-6
Rear Panel................................................................................................................ 1-7

Chapter

2

Installation
Installation Requirements ........................................................................................ 2-2
Items supplied with the basic CMC Kit............................................................ 2-2
Items not supplied with the CMC Kit............................................................... 2-6

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: a-frnt.doc Last Saved On: 6/20/01 3:04 AM

iv

Compaq Console Management Controller User Guide

Installation Procedures............................................................................................. 2-7
Installing the Standard Sensors ......................................................................... 2-8
Connecting the Cord Retention Bracket ......................................................... 2-17
Connecting the Sensors to the CMC ............................................................... 2-18
Connecting the Fan Assemblies...................................................................... 2-19
Connecting the Input Power Cord to the CMC ............................................... 2-20
Connecting the CMC to Utility Power............................................................ 2-21
Connecting the Network Cable ....................................................................... 2-22
Securing Cables to the CMC........................................................................... 2-22
Mounting the CMC in the Rack...................................................................... 2-23
Powering on the CMC .................................................................................... 2-23
Configuring the CMC ..................................................................................... 2-24
Using the Front Serial Port ............................................................................. 2-25
Installation Completion.......................................................................................... 2-25

Chapter

3

Operation
LCD Menu ............................................................................................................... 3-2
Status Menu ...................................................................................................... 3-3
System Information Menu ................................................................................ 3-4
Setup Menu ....................................................................................................... 3-5
Alert Handling ......................................................................................................... 3-6
Silencing an Audible Alarm.............................................................................. 3-7
Deactivating an Alarm Relay............................................................................ 3-7

Chapter

4

Software
Compaq Intelligent Rack Manager Lite Software.................................................... 4-1
System Requirements............................................................................................... 4-2
Preinstallation Tasks ................................................................................................ 4-2
Software Installation ................................................................................................ 4-3
Uninstalling the Software ................................................................................. 4-4
Accessing the Software..................................................................................... 4-4
Logging In to the Software ............................................................................... 4-5
Screen Layout .......................................................................................................... 4-5
Software Settings ..................................................................................................... 4-6
Add/Remove Device Screen ............................................................................. 4-7
Messaging Setup Screen ................................................................................... 4-8
Email Setup Screen ........................................................................................... 4-9
Pager Setup Screen ......................................................................................... 4-10

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: a-frnt.doc Last Saved On: 6/20/01 3:04 AM

About This Guide

Change Password Screen................................................................................ 4-11
Device Configuration............................................................................................. 4-12
CMC Properties Screen .................................................................................. 4-13
Sensor Setup Screen ....................................................................................... 4-15
Accessory Setup Screen.................................................................................. 4-16
Threshold Configuration Screen..................................................................... 4-18
Alert Handling Screen .................................................................................... 4-19
Manual Control Screen................................................................................... 4-20
Log Screen...................................................................................................... 4-22
Device Monitoring................................................................................................. 4-22
Active Alarms Screen..................................................................................... 4-23
Device Home Screen ...................................................................................... 4-24
Terminal Program Operation ................................................................................. 4-26
Starting HyperTerminal.................................................................................. 4-26
Navigating Menus........................................................................................... 4-27

Chapter

5

Troubleshooting
Troubleshooting During Startup .............................................................................. 5-2
Troubleshooting After Startup ................................................................................. 5-3
Repairing the CMC.................................................................................................. 5-3

Appendix

A

Regulatory Compliance Notices
Regulatory Compliance Identification Numbers .....................................................A-1
Federal Communications Commission Notice ........................................................A-2
Class A Equipment ...........................................................................................A-2
Class B Equipment ...........................................................................................A-3
Modifications....................................................................................................A-4
Canadian Notice (Avis Canadien) ...........................................................................A-4
Class A Equipment ...........................................................................................A-4
Class B Equipment ...........................................................................................A-4
European Union Notice ...........................................................................................A-5
Japanese Notice .......................................................................................................A-5
China Taiwan Notice................................................................................................A-5

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: a-frnt.doc Last Saved On: 6/20/01 3:04 AM

v

vi

Compaq Console Management Controller User Guide

Appendix

B

Electrostatic Discharge
Grounding Methods .................................................................................................B-2

Appendix

C

Specifications
Specifications...........................................................................................................C-2

Appendix

D

Pin Layout Configuration
Compaq CMC ......................................................................................................... D-1

Index

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: a-frnt.doc Last Saved On: 6/20/01 3:04 AM

About This Guide

This guide is designed to be used as step-by-step instructions for installation
and as a reference for operation, troubleshooting, and future upgrades.

Text Conventions
This document uses the following conventions to distinguish elements of text:
Keys

Keys appear in boldface. A plus sign (+) between
two keys indicates that they should be pressed
simultaneously.

USER INPUT

User input appears in a different typeface and in
uppercase.

FILENAMES

Filenames appear in uppercase italics.

Menu Options,
Command Names,
Dialog Box Names

These elements appear in initial capital letters.

COMMANDS,
DIRECTORY NAMES,
and DRIVE NAMES

These elements appear in uppercase.

Type

When you are instructed to type information, type
the information without pressing the Enter key.

Enter

When you are instructed to enter information, type
the information and then press the Enter key.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: a-frnt.doc Last Saved On: 6/20/01 3:04 AM

viii

Compaq Console Management Controller User Guide

Symbols in Text
These symbols may be found in the text of this guide. They have the following
meanings.
WARNING: Text set off in this manner indicates that failure to follow directions
in the warning could result in bodily harm or loss of life.
CAUTION: Text set off in this manner indicates that failure to follow directions
could result in damage to equipment or loss of information.
IMPORTANT: Text set off in this manner presents clarifying information or specific
instructions.
NOTE: Text set off in this manner presents commentary, sidelights, or interesting points
of information.

Symbols on Equipment
These icons may be located on equipment in areas where hazardous conditions
may exist.
This symbol in conjunction with any of the following symbols indicates the
presence of a potential hazard. The potential for injury exists if warnings
are not observed. Review the documentation for specific details.
This symbol indicates the presence of hazardous energy circuits or electric
shock hazards. Refer all servicing to qualified personnel.
WARNING: To reduce the risk of injury from electric shock hazards, do not
open this enclosure. Refer all maintenance, upgrades, and servicing to
qualified personnel.
This symbol indicates the presence of electric shock hazards. The area
contains no user or field serviceable parts. Do not open for any reason.
WARNING: To reduce the risk of injury from electric shock hazards, do
not open this enclosure.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: a-frnt.doc Last Saved On: 6/20/01 3:04 AM

About This Guide

This symbol on an RJ-45 receptacle indicates a Network Interface
Connection.
WARNING: To reduce the risk of electric shock, fire, or damage to the
equipment, do not plug telephone or telecommunications connectors into
this receptacle.
This symbol indicates the presence of a hot surface or hot component. If
this surface is contacted, the potential for injury exists.
WARNING: To reduce the risk of injury from a hot component, allow the
surface to cool before touching.

Important Safety Information
Before installing this product, read the Important Safety Information guide
provided in the Console Management Controller (CMC) Kit.

Rack Stability
WARNING: Make sure that the rack containing the CMC is stable. The following
conditions must be met:
■
■
■
■
■

The leveling feet are extended to the floor.
The full weight of the rack rests on the leveling feet.
The stabilizing feet are attached to the rack if it is a single-rack
installation.
The racks are coupled together in multiple-rack installations.
A rack may become unstable if more than one component is extended for
any reason. Extend only one component at a time.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: a-frnt.doc Last Saved On: 6/20/01 3:04 AM

ix

x

Compaq Console Management Controller User Guide

Getting Help
If you have a problem and have exhausted the information in this guide, you
can get further information and other help in the following locations.

Compaq Technical Support
In North America, call the Compaq Technical Phone Support Center at
1
1-800-652-6672 (1-800-OK-COMPAQ) . This service is available 24 hours a
day, 7 days a week.
Outside North America, call the nearest Compaq Technical Support Phone
Center. Telephone numbers for world wide Technical Support Centers are
listed on the Compaq website. Access the Compaq website at
http://www.compaq.com.
Be sure to have the following information available before calling Compaq:
Technical support registration number (if applicable)

■
■

Product serial number(s)

■

Product model name(s) and number(s)

■

Applicable error messages

■

Add-on boards or hardware

■

Third-party hardware or software

■

Operating system type and revision level

■

Detailed, specific questions

Compaq Website
For more information on Compaq products, access the Compaq website at
www.compaq.com.

Compaq Authorized Reseller
For the name of the nearest Compaq authorized reseller:

1

■

In the United States, call 1-800-345-1518.

■

In Canada, call 1-800-263-5868.

■

Elsewhere, access the Compaq website at www.compaq.com.

For continuous quality improvement, calls may be recorded or monitored.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: a-frnt.doc Last Saved On: 6/20/01 3:04 AM

Chapter

1

Overview

This chapter contains information on the following topics:
■

Compaq Console Management Controller

■

General description

■

Standard CMC features

■

Front panel

■

Rear panel

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: b-ch1 Overview.doc Last Saved On: 7/13/01 2:29 PM

1-2

Compaq Console Management Controller User Guide

Compaq Console Management Controller
The Console Management Controller (CMC) offers one model, part number
203039-B21. This unit is rack-mountable and is Worldwide voltage adaptable.

General Description
The CMC is a rack-mounted device intended to monitor and control the
environment within a single-rack or multiple-rack suites. The system consists
of a CMC, several sensors, and the Compaq Intelligent Rack Manager Lite
software. With the software, you can easily configure the CMC, remotely
receive system status and alerts, and initiate planned actions. Optional sensor
kits are available to expand the capabilities of the CMC and include additional
temperature, humidity, vibration and intrusion sensors, as well as smoke
detection and electronic door locks.
A number of sensors can be connected to the CMC to monitor temperature,
humidity, smoke, mechanical shock/vibration, and security. With the proper
setup, the system can:
■

Monitor voltage within the rack.

■

Monitor temperature within the rack

■

Monitor humidity levels in the rack.

■

Detect whether rack doors are open or closed.

■

Detect someone tampering with the rack.

■

Detect smoke within the rack.

■

Remotely lock and unlock the rack doors.

The system can be programmed with thresholds for the sensors to trigger
alarms, and programmed to take action on those alarms. For example, from the
Console, the CMC can be programmed to turn the rack fans on when the rack
temperature is too warm or turn the rack fan assemblies off if smoke is
detected. Should an unauthorized person attempt to enter the rack, the system
may sound an audible alarm, send an alert message to the Console, send an
e-mail, send a page, or activate an alarm relay switch connected to some
device set up by the user, such as a siren, or rotating light.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: b-ch1 Overview.doc Last Saved On: 7/13/01 2:29 PM

Overview

Standard CMC Features
■

1U design

■

Ethernet communications port for data exchange with a host computer

■

Four analog inputs:
G

Two temperature inputs

G

One humidity input

G

One voltage monitor for AC mains

■

Two programmable fan output power controls

■

Eight discrete inputs
G

Four intrusion inputs

G

One smoke input

G

One mechanical shock/vibration input

G

Two Auxiliary (AUX) inputs

■

Two electronic door lock controls

■

Easy configuration via:
G

Compaq Intelligent Rack Manager Lite

G

Serial port on front panel

G

SNMP - TCP/IP

G

User inputs on front panel

■

Audible and visual alarm indicators

■

Monitoring of up to two racks

■

Two user-programmable alarm outputs, for rotating lights or other alarm
devices (not included)
NOTE: If the external temperature sensors are not connected, the internal temperature of
the unit will be displayed.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: b-ch1 Overview.doc Last Saved On: 7/13/01 2:29 PM

1-3

1-4

Compaq Console Management Controller User Guide

Communications Ports
The communications port for data exchange with the host computer consists of
an Ethernet port (RJ-45) using SNMP communication.
The serial communication port (RJ-11) allows for the use of a VT100/Xmodem device.

Compaq Intelligent Rack Manager Lite
With each CMC, Compaq supplies a CD containing Intelligent Rack Manager
Lite software. This software permits the administrator to monitor and manage
the rack environment through the Internet using Internet Explorer.
Software capabilities include the following:
■

Configuring the CMC

■

Monitoring the following sensors:
G

Input voltage

G

Temperature (up to two)

G

Humidity

G

Smoke

G

Mechanical shock/vibration

G

Intrusion (up to four doors)

■

Controlling door locks for one or two racks

■

Activating relay controls

■

Activating and monitoring up to two rack fan arrays

■

Logging all events

■

Sending a Windows message

■

Sending an email message

■

Sending a pager notification

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: b-ch1 Overview.doc Last Saved On: 7/13/01 2:29 PM

Overview

Front Panel
The CMC is rack-mountable in a 1U configuration.

1

2

3

4

5

6

8

9

10

7

Figure 1-1. Front panel configuration

Table 1-1
CMC Front Panel









	



Alarm LED
Network LED
Serial communication LED
Serial communication port (RJ-11)
Escape button
Scroll up button
Enter/Alarm silence button
LCD display
Power LED
Power button

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: b-ch1 Overview.doc Last Saved On: 7/13/01 2:29 PM

1-5

1-6

Compaq Console Management Controller User Guide

Front Panel Controls
The CMC front panel includes the controls required to:
■

Power the unit On or Off.

■

Scroll through LCD menus.

■

Select LCD menu items.

■

Silence audible alarms and deactivate alarm relays (if these features are
enabled in the control software).
NOTE: For information about changing the configuration on the CMC, or to check the
current configuration, see Chapter 4, “Software.”

Front Panel LEDs
Each LED is described in the following table. See Table 1-1 for reference.

Table 1-2
Front Panel LEDs
LED

Reference

Color



Alarm LED

Red



	

Meaning
General alarm indicator (blinking).

Orange

Warning (intrusion alert/temperature warning).

Green

No alarm.

Network LED

Green

Normally On. Blinking indicates activity.

Serial
Communication
LED

Green

Normally Off. Blinking indicates communication.

Power LED

Green

Power On.



NOTE: Alarm status may be viewed in the LCD display ( ) or the system console.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: b-ch1 Overview.doc Last Saved On: 7/13/01 2:29 PM

Overview

Rear Panel
The CMC features the following rear panel configuration:

1

2

3

4

5

6

7

8

9 11 13 15 17

10 12 14 16

19

18

21

20

Figure 1-2. Rear panel configuration

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: b-ch1 Overview.doc Last Saved On: 7/13/01 2:29 PM

1-7

1-8

Compaq Console Management Controller User Guide

Table 1-3
CMC Rear Panel









	














Description

Type of connector

Main power input

AC input (IEC 320-10A)

Input voltage monitor / Power
input for Fan #1 and #2

AC input (IEC 320-10A)

Fan #1

Power output for fan #1 (IEC 320–10A)

Fan #2

Power output for fan #2 (IEC 320–10A)

Relay #1

Alarm relay (RJ-12)

Relay #2

Alarm relay (RJ-12)

Intrusion sensor #1

Discrete input (RJ-12)

Intrusion sensor #2

Discrete input (RJ-12)

Intrusion sensor #3

Discrete input (RJ-12)

Intrusion sensor #4

Discrete input (RJ-12)

Smoke sensor

Discrete input (RJ-12)

Shock/vibration sensor

Discrete input (RJ-12)

Lock #1

Discrete output (RJ-12)

Lock #2

Discrete output (RJ-12)

Auxiliary 1

Discrete input (RJ-12)

Auxiliary 2

Discrete input (RJ-12)

Temperature sensor #1

Analog input (RJ-12)

Temperature sensor #2

Analog input (RJ-12)

Humidity sensor

Analog input (RJ-12)

2

2

I C port

I C communications (RJ-45)

Ethernet port

10BaseT (RJ-45)

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: b-ch1 Overview.doc Last Saved On: 7/13/01 2:29 PM

Chapter

2

Installation

This chapter provides information on the following topics:
■

Installation requirements

■

Installation procedures

■

Powering on the CMC

■

Completing the installation

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

2-2

Compaq Console Management Controller User Guide

Installation Requirements
This section lists items required to install the CMC.

Items supplied with the basic CMC Kit
The CMC Kit (Compaq Part Number 203039-B21) contains the following
components:

Hardware

Figure 2-1. CMC kit contents (hardware)
Console Management
Controller






Network cable
(RJ-45 to RJ-45)



RJ-12 to pigtail cables for relay
ports
Jumper power cords for fan
arrays and for main input
power via UPS (IEC 320 to 320)

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

Installation



	




Input power cord
(country-specific)
Tie wraps
Serial communication cable
(RJ-11 to DB-9)
Sensor cable
Sensor cable
Sensor cable










Voltage monitor cord/fan input
cord (country-specific)
Screws, washers and cage
nuts
Intrusion sensors (2 sets)
Double-sided tape
Cord management clips
Temperature sensor
Cord retention bracket

Software/Reference Material
■

Important Safety Information guide to be reviewed before installing this
product

■

Power Products Documentation CD

■

Compaq Intelligent Rack Manager Lite CD

■

Compaq Console Management Controller User Guide

■

Warranty information

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

2-3

2-4

Compaq Console Management Controller User Guide

Optional Sensor Kit, with assorted cable lengths
Compaq Part Number 203039-B22 (sold separately)

Figure 2-2. Optional sensor kit content
Temperature sensor





	


Sensor cable
Sensor cable
Sensor cable
Sensor cable
Humidity sensor










Humidity sensor bracket
Screws and cage nuts
Tie wraps
Shock/vibration sensor
Intrusion sensors (2 sets)
Double sided tape
Cord management clips

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

Installation

Optional Smoke Sensor Kit
Compaq Part Number 203039-B24 (sold separately)

Figure 2-3. Optional smoke sensor kit contents





Smoke sensor
Sampling tube sections
Tube couplings


	


End cap
Screws
Sampling tube bracket

Optional Door Locking Kit
Compaq Part Number 203039-B23 (sold separately)

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

2-5

2-6

Compaq Console Management Controller User Guide

Items not supplied with the CMC Kit
Tools
■

A medium flat-bladed screwdriver and a #2 Phillips screwdriver

■

Cage nut-fitting tool (supplied with the Compaq rack)
IMPORTANT: Only use the power cords supplied with the CMC. If the CMC does not
include a power cord that is suitable for your application, contact an authorized Compaq
service representative to obtain the appropriate power cord. Refer to the “Precautions for
Power Products” section of Important Safety Information (guide included with the CMC
Kit.)

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

Installation

Installation Procedures
This section provides installation steps to install the CMC.
1. Attach the cord retention bracket to the CMC.
2. Install the sensors in the racks.
3. Connect the sensors to the CMC unit.
4. Connect the main input power cord to the CMC, or if an Uninterruptible
Power System (UPS) will be used for main power, connect the power
jumper cord to the CMC.
5. Connect the input power/voltage monitor cord to the CMC.
6. Connect jumper power cords to the fan assemblies.
7. Secure the cables to the cord retention bracket.
8. Mount the CMC in the rack.
9. Plug the input power cord to a UPS or AC power source.
10. Plug the fan input power cord to an AC source.
11. Secure the cables to the rack.
12. Power up the CMC.
13. Set the initial configuration using the front panel controls.
14. Insert the software CD.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

2-7

2-8

Compaq Console Management Controller User Guide

Installing the Standard Sensors
The sensor cables may be routed through the rack and then attached to the rack
by using the stick-on cable management clips or tie wraps.

Temperature Sensor
The temperature sensor can be installed on the ceiling of the rack, towards the
rear, or near the most temperature-sensitive component in the rack.

Figure 2-4. Installing the temperature sensor

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

Installation

Intrusion Sensor

Intrusion Sensor
An intrusion sensor consists of two parts:
■

A magnet

■

An electrical switch

1. The magnet should be installed on the inside of the rack door and the
electrical switch on the rack as shown in the following instructions.
Make sure the magnet and switch align with each other and allow
sufficient clearance for the doors to close.
2. The intrusion sensors should be installed on the front door
as well as the rear door .



1

 of the rack,

2

Figure 2-5. Installing the intrusion sensor in the 9000 series rack

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

2-9

2-10

Compaq Console Management Controller User Guide

1

2

Figure 2-6. Installing the intrusion sensor in the 7000 series rack

To connect a series of intrusion sensors to the same CMC port, remove the
plug shipped in the sensor and connect the cable from an additional intrusion
sensor, as shown below.
1

2

Figure 2-7. Intrusion sensor

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

Installation

Installing the Optional Sensors
Temperature sensor
■

The optional temperature sensor should be installed on the ceiling of the
second rack, towards the rear. (See Figure 2-4)

Intrusion sensor
■

The optional intrusion sensors should be mounted on the doors of the
second rack. (See Figures 2-5 and 2-6)

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

2-11

2-12

Compaq Console Management Controller User Guide

Humidity sensor
■

The optional humidity sensor should be installed as follows:
a. Install the bracket for the humidity sensor
larger screws.
b. Fasten the sensor unit

 to the rack using the

 to the bracket using the smaller screws.

 over the sensor unit.
d. Connect the sensor cable  to the sensor unit.
c. Snap the cover

1

2

4

3

Figure 2-8. Installing the humidity sensor in the 9000 series rack

1

2

4

3

Figure 2-9. Installing the humidity sensor in the 7000 series rack

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

Installation

Mechanical shock/vibration sensor
■

Install the optional mechanical shock/vibration sensor on the rails of the
rack as follows:

Figure 2-10. Installing the vibration sensor in the 9000 rack

Figure 2-11. Installing the vibration sensor in the 7000 rack

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

2-13

2-14

Compaq Console Management Controller User Guide

Smoke sensor kit
■

Install the optional smoke sensor as follows:



a. Place the smoke sensor on rear rack door. Then place the screws
with washers through the holes in the door and secure the sensor.



IMPORTANT: For the smoke sensor to be effective, the sampling tube must be placed in
the path of the exhaust air from the equipment within the rack.

b. Install a tube coupling on a section of the sampling tube. Insert the
coupling into the smoke sensor. Position the holes in the tube to face
the equipment in the rack. Hand-tighten the connection of the
coupling and smoke sensor.
c. Add couplings and tubes until the tube reaches the bottom of the
door.
d. Insert the plastic end cap on the bottom of the tube to secure the
bracket to the end of the tube .



e. Align the bottom tube



 vertically with the sensor .

f. Insert a screw (with washer) through the hole in the door and
fasten it to the tube bracket using a nut.



2
1

4

3

Figure 2-12. Installing the smoke sensor

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

Installation

g. Route the sensor cable through the rack.
h. Attach the cable to the rack with the stick-on cable retention clips or
tie wraps included in the CMC basic unit.
i. Connect the cable to the sensor

.

1

Figure 2-13. Connecting the smoke sensor

Smoke Sensor Operation
NOTE: The smoke sensor is for use only with the CMC and is not suitable for connection
to building fire alarm systems.

Smoke passing by the sampling tube will be drawn into the optical smoke
sensor by the fan. The smoke sensor can take up to 20 seconds to trigger an
alarm to the CMC. The sampling tube must be placed in the path of the
exhaust air from the rack equipment.
If smoke is detected, the sensor fan will automatically shut off. After the
smoke has cleared, the sensor can be reset by pressing the RESET button for
three seconds.
The sensor will not detect smoke if the fan stops running or runs too slowly. A
fan fault like this will also trigger a smoke alarm. A smoke alarm should be
investigated to determine whether smoke is present or a fan fault occurred.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

2-15

2-16

Compaq Console Management Controller User Guide

Smoke Sensor Maintenance
Keep the sampling tube and holes clean and clear of dust and debris at all
times.
Check the smoke sensor at least once per year. Use smoke test gas to check
and verify proper unit functionality.
Compaq recommends replacing the smoke sensor after the sensor detects a
fire. Contact a Compaq authorized representative for ordering details.

Door locking kit
■

The optional door locking kit should be installed on the front and rear
doors of the rack. Install the optional door locking kit according to the
installation instructions included with the kit.
NOTE: The door locking kit is only for use with the Compaq CMC.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

Installation

Connecting the Cord Retention Bracket



Remove the screws from the rear of the CMC. Align cord retention bracket
with the holes in the rear of the unit and insert screws .

1



1
1

1

Figure 2-14. Connecting the cord retention bracket

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

2-17

2-18

Compaq Console Management Controller User Guide

Connecting the Sensors to the CMC
The sensors connect to the rear of the CMC. See Table 1-4, for a description of
the rear connectors.

1

2

3

4

5

6

7

8

9 11 13 15 17

10 12 14 16

19

18

21

20

Figure 2-15. CMC rear panel

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

Installation

Connecting the Fan Assemblies
The fan assemblies should be connected to the fan power output sockets
and . The input power/voltage monitoring cord should be connected to
the input power plug . The cable is connecting the rack fan array in the
second rack.







2

3

A

4

A

Figure 2-16. Connecting fan assemblies

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

2-19

2-20

Compaq Console Management Controller User Guide

Connecting the Input Power Cord to the CMC



Make sure the Power button is in the Off position before connecting the
input power cord to the rear of the unit.

10

Figure 2-17. Power Button

Connect the input power cord to the input power socket

.

1

Figure 2-18. Input power connection

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

Installation

Connecting the CMC to Utility Power
If a UPS is installed in the rack, connect the CMC to the UPS. If a UPS is not
installed in the rack, use a grounded utility power outlet.
The power for the fan outputs comes from the voltage monitor input. If the
rack configuration includes fans, the rack fans must be powered from the fan
power output sockets.
NOTE: Do not connect the voltage monitor input to a UPS.
WARNING: To reduce the risk of electric shock or damage to the equipment,
take these precautions:
■

Plug the input line cord into a grounded (earthed) electrical outlet that is
installed near the equipment and is easily accessible.

■

Do not disable the grounding plug on the input line cord. The grounding
plug is an important safety feature.

■

Do not use extension cords.

WARNING: Power grounds for the main AC input and the voltage monitor input
are tied common within the CMC.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

2-21

2-22

Compaq Console Management Controller User Guide

Connecting the Network Cable
Connect the network cable to the RJ-45 socket.

Figure 2-19. Connecting the network cable

Securing Cables to the CMC
Use the tie wraps (included with the CMC Kit) to secure the cables to the
cable retention bracket.

Figure 2-20. Securing cables to the CMC

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

Installation

Mounting the CMC in the Rack
The CMC mounts directly to the rack in a 1U configuration. Refer to the
Compaq Console Management Controller Installation Instructions (supplied
with the CMC Kit) for directions.

Figure 2-21. Mounting the unit in the rack

Powering on the CMC
Power On the unit by pressing the Power button

.

10

Figure 2-22. Turning the unit On

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

2-23

2-24

Compaq Console Management Controller User Guide

Configuring the CMC
Use the front panel for basic configuration of the unit. The CMC is fully
localized to allow for complete functionality of the front panel in multiple
languages.

6

5

8

7

Figure 2-23. CMC front panel

Selecting the Language
Use the CMC front panel controls to select the appropriate language. To select
the language:

 to select the appropriate language.
2. Press Enter/Alarm Silence  to save the language selection.
1. Press Scroll Up

Setting the IP Address
Use the CMC front panel controls to set the CMC IP address. To set the IP
address:
■

Press Scroll Up

 and Enter/Alarm Silence  to set the IP address.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

Installation

Setting the Subnet Mask



■

Press Scroll Up and Enter/Alarm Silence
address. The default setting is 0.0.0.0.

■

The CMC will automatically reboot.

 to set the Subnet Mask

NOTE: For more detailed configuration instructions, see Chapter 4, “Software.”

Using the Front Serial Port
The serial port on the front panel may be used with a laptop computer to
configure the CMC.
NOTE: For more detailed configuration instructions, see Chapter 4, “Software.”

Figure 2-24. Connecting to the serial port

Installation Completion
Installation is now complete. For information on operating the CMC, see
Chapter 3, “Operation.” Use the Compaq website at www.compaq.com as an
additional information source.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: c-ch2 Installation.doc Last Saved On: 7/19/01 10:30 PM

2-25

Chapter

3

Operation

This chapter contains information on the following topics:
■

LCD menu

■

Alert handling

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: d-ch3 Operation.doc Last Saved On: 6/20/01 7:06 PM

3-2

Compaq Console Management Controller User Guide

LCD Menu

6

5

8

7

Figure 3-1. LCD menu and control buttons

From the LCD menu
and Setup.

, access information on Status, System Information,

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: d-ch3 Operation.doc Last Saved On: 6/20/01 7:06 PM

Operation

Status Menu

 one time to select the Main menu.
2. Press Enter/Alarm Silence  one time to select the Status menu.
3. Press Scroll Up  to scroll through the menu selections:
1. Press Enter/Alarm Silence

G

Temperature 1

G

Temperature 2

G

Fan 1

G

Fan 2

G

Voltage

G

Humidity

G

Door/Panel 1

G

Door/Panel 2

G

Door/Panel 3

G

Door/Panel 4

G

Lock Set 1

G

Lock Set 2

G

Locking dev. 1

G

Locking dev. 2

G

Smoke

G

Mechanical shock/vibration

G

Aux 1

G

Aux 2

4. Press Escape

 to return to the Main menu.

NOTE: If the external temperature sensors are not connected, the internal temperature of
the unit displays.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: d-ch3 Operation.doc Last Saved On: 6/20/01 7:06 PM

3-3

3-4

Compaq Console Management Controller User Guide

System Information Menu
See Figure 3-1, for a description of the LCD menu.

 one time to access the System Information menu.
2. Press Enter/Alarm Silence  one time to select the System
1. Press Scroll Up

Information menu.

3. Press Scroll Up

 to scroll through the menu selections:

G

Hardware version

G

Firmware version

G

Software version

G

Device number

G

MIB version

G

System name

G

System location

G

System contact

G

Operating time

G

System time

4. Press Escape

 to return to the Main menu.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: d-ch3 Operation.doc Last Saved On: 6/20/01 7:06 PM

Operation

Setup Menu
See Figure 3-1, for a description of the LCD menu.

 one time to access the Setup menu.
2. Press Enter/Alarm Silence  one time to select Setup menu.
3. Press Scroll Up  to scroll through the menu selections:
1. Press Scroll Up

G

Threshold fan 1

G

Threshold fan 2

G

Language

G

Temperature unit

G

IP address

G

IP mask

G

IP router

G

Password - Enable/Disable

4. Press Escape

 to return to the System Information menu.


NOTE: To change one of these values, press Enter/Alarm Silence to select the entry,
Scroll Up to change the value, and Enter/Alarm Silence to confirm the change, or
Escape to cancel.






Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: d-ch3 Operation.doc Last Saved On: 6/20/01 7:06 PM

3-5

3-6

Compaq Console Management Controller User Guide

Alert Handling
An alert triggers an action as configured in the software. Possible actions,
based on an alert, are identified below. Each alert can trigger any or all of
these actions.
■

Audible alarm

■

Activate relay #1

■

Activate relay #2

■

Send a Microsoft Windows message to monitoring computer

■

Send an alert via e-mail

■

Send an alert via pager

Examples:
■

Intrusion alert on Door #1 activates an audible alarm and pages the
system administrator.

■

Voltage out of specification pages the system administrator.
IMPORTANT: For more information regarding enabling and disabling alarms, see
Chapter 4, “Software.”

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: d-ch3 Operation.doc Last Saved On: 6/20/01 7:06 PM

Operation

Silencing an Audible Alarm



To silence an audible alarm, press Enter/Alarm Silence . You can enable or
disable the silencing feature in the software for all CMC alerts to ensure that
an unauthorized individual cannot turn off an audible alarm.

7

Figure 3-2. The Enter/Alarm Silence button
IMPORTANT
■

Pressing the Enter/Alarm Silence button quiets the alarm, but does not clear the
condition that originally initiated the alarm. The alert will remain active on the
management console until the condition returns to normal.

■

When the Enter/Alarm Silence button is pressed, silencing the alarm, any
subsequent alarm will again cause the alarm to sound.

Deactivating an Alarm Relay



To deactivate an alarm relay, press Enter/Alarm Silence . You can enable
or disable this deactivation feature in the software for all CMC alerts to ensure
that an unauthorized individual cannot turn off an active alarm relay output.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: d-ch3 Operation.doc Last Saved On: 6/20/01 7:06 PM

3-7

Chapter

4

Software

This chapter describes the management of rack environments using Compaq
CMCs that are controlled using Compaq Intelligent Rack Manager Lite
software.

Compaq Intelligent Rack Manager Lite
Software
Compaq Intelligent Rack Manager Lite software is a Java-based application
that runs a web server. Intelligent Rack Manager Lite ensures maximum
reliability of Compaq computer systems through flexible and comprehensive
remote monitoring of rack environments using Compaq CMCs. The software
compiles information about all network-connected CMCs, allowing remote
monitoring, configuration, management, and control of these devices.
NOTE: Compaq Intelligent Rack Manager Lite software is not essential for the operation
of the CMC. The basic configuration of the CMC can be operated with the following:
■

The front panel control buttons—Configuring a CMC with the front panel control
buttons is discussed in the section titled “LCD Menu,” in Chapter 3 of this guide.

■

A terminal program—Managing a CMC with a terminal program is discussed at the
end of this chapter.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

4-2

Compaq Console Management Controller User Guide

System Requirements
Intelligent Rack Manager Lite software requires the following minimum
hardware and software:
■

100-MHz Pentium computer
G

50 MB free disk space

G

32 MB RAM

■

Windows NT 4.0 or Windows 2000

■

Internet Explorer 5.0 or later

■

A Mail Application Program Interface (MAPI)-compatible email system
for email notification of alerts

■

An installed modem for pager notification of alerts

Preinstallation Tasks
Use the CMC front panel controls to perform the following tasks before
beginning the software installation:
■

Selecting the language—See “Selecting the Language” in Chapter 2 of
this guide.

■

Setting the IP address—See “Setting the IP Address” in Chapter 2 of
this guide.

■

Setting the subnet mask—See “Setting the Subnet Mask” in Chapter 2
of this guide.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

Software

Software Installation
The Intelligent Rack Manager Lite software CD is provided in the CMC kit.
NOTE: To install the Intelligent Rack Manager Lite software, you must have Administrator
rights.

To install the software using this CD:
1. Insert the CD into the CD-ROM drive of any network-connected
computer. If the AutoPlay feature is enabled, the Install Wizard
automatically starts. If the AutoPlay feature is disabled, explore the CD
and double-click INSTALL.HTM in the root directory to begin software
installation.
A security warning displays.
2. Click Yes to accept the security warning. The Intelligent Rack Manager
Lite CD menu displays.
3. Click Start Installer for Windows NT, 2000. The Install Wizard runs.
4. Select the appropriate language for the installation and click OK. The
Introduction window displays.
5. Read the introduction and click Next. The License Agreement window
displays.
6. Read the license agreement, click Yes to accept the license agreement,
then click Next. The Choose Install Folder window displays.
7. Click Install to install the software in the default folder. To specify the
folder in which the software installs, click Choose..., navigate to the
appropriate folder, then click Install.
The software installation begins and a horizontal status bar indicates the
installation progress. The Install Complete window displays.
8. Click Done when the software is installed.
IMPORTANT: The Compaq Intelligent Rack Manager lite software application requires
Microsoft’s Virtual machine TM to be installed, in order to run properly. During the
software installation process you will be guided to the Microsoft Web page where
Microsoft Virtual Machine can be downloaded. Or, visit www.microsoft.com/java and
download the Virtual Machine prior to installing the Compaq Intelligent Rack Manager lite
software application.
NOTE: You will only be guided to the Microsoft web page if Virtual Machine is not already
installed.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

4-3

4-4

Compaq Console Management Controller User Guide

Uninstalling the Software
NOTE: To uninstall the Intelligent Rack Manager Lite software, you must have
Administrator rights.

To remove the Intelligent Rack Manager Lite software from the system:
1. Select Start, Programs.
2. Select the Compaq Intelligent Rack Manager Lite program group.
3. Select Uninstall. The software uninstalls.

Accessing the Software
Intelligent Rack Manager Lite can be accessed from the host computer or any
other network-connected computer.
To access the Intelligent Rack Manager Lite software from the host computer:
1. Select Start, Programs.
2. Select the Compaq Intelligent Rack Manager Lite program group.
3. Click Compaq Intelligent Rack Manager Lite. A browser window
opens and the Intelligent Rack Manager Lite software Login screen
displays.
To access the Intelligent Rack Manager Lite software from a
network-connected computer:
1. Double-click the Internet Explorer icon on the desktop or select Start,
Programs, Internet Explorer. The browser window displays.
2. In the Address field, type
http://location:8001/

where location is the IP address or the name of the computer on
which the software was installed. The computer name can only be used
if the computer has a DNS entry.
3. Click Go. The Intelligent Rack Manager Lite software Login screen
displays.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

Software

Logging In to the Software

Figure 4-1. Login screen

Before using the Intelligent Rack Manager Lite software, you must log in with
a username and password. The first time you log in, enter Administrator
as the username and Administrator as the password. Click Enter
Password to log in. After you are logged in, customize your password as
described in “Change Password Screen” later in this chapter.
NOTE: Passwords are case sensitive.

Screen Layout

Figure 4-2. Intelligent Rack Manager Lite software screen layout

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

4-5

4-6

Compaq Console Management Controller User Guide

The Intelligent Rack Manager Lite software interface is divided into three
frames:
■

Top frame—Contains the title, a Settings icon, a Devices icon, and a
Logout icon.
G

Click the Settings icon to view a list of links to the software settings
screens.

G

Click the Devices icon to view a list of links to the device
configuration screens.

G

Click the Logout icon to log out of the software.

■

Left frame—Contains a list of links to other screens. The links in the
list change depending on which screen you are viewing.

■

Main frame—Contains the various screens of the software, which are
discussed in detail in the following sections. Click the Help icon on any
screen in the main frame to display the Compaq Intelligent Rack
Manager Lite software online help.

Software Settings
To configure the software, click the Settings icon in the top frame of the
interface. A list of links to software setup pages displays in the left frame:
■

Add/Remove Device

■

Messaging Setup

■

Email Setup

■

Pager Setup

■

Change Password

Each software settings screen is labeled Software Settings.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

Software

Add/Remove Device Screen

Figure 4-3. Add/Remove Device screen

Click the Add/Remove Device link to access the Add/Remove Device screen.
The Intelligent Rack Manager Lite software only recognizes CMC devices that
are listed on the Add/Remove Device screen.
To add a CMC to the software:
1. Type the IP address of the CMC in the IP Address field. See “Setting
the IP Address” in Chapter 2.
2. Click Add to add the CMC to the list of recognized devices.
NOTE: Type in a range of IP addresses to locate several CMC devices. The software only
recognizes ranges at the end of an IP address, for example 200.200.200.201-213.

To remove a CMC from the software:
1. Highlight the IP address of the CMC you want to remove.
2. Click Remove to remove the CMC from the list of recognized devices.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

4-7

4-8

Compaq Console Management Controller User Guide

Messaging Setup Screen

Figure 4-4. Messaging Setup screen

Click the Messaging Setup link to access the Messaging Setup screen. Use
this screen to set the computer names to which popup messages can be sent
when CMC alerts occur.
NOTE: The added computer names become available on the Alert Handling screen, where
each name must be configured to receive specific alerts. See the section “Alert Handling
Screen,” later in this chapter.

To add a computer name to the popup alert list:
1. Type a valid computer name in the Users field.
2. Click Add to add the name to the list.
To remove a computer name from the popup alert list:
1. Highlight the computer name you want to remove.
2. Click Remove to remove the name from the list.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

Software

Email Setup Screen

Figure 4-5. Email Setup screen

Click the Email Setup link to access the Email Setup screen. Use this screen
to set the email addresses to which email messages can be sent when CMC
alerts occur.
NOTE: The added email addresses become available on the Alert Handling screen, where
each address must be configured to receive specific alerts. See the section “Alert
Handling Screen,” later in this chapter.

Before email alerts can be sent, configure the software for the mail system:
NOTE: Ask the system administrator to assign a mail account to the Intelligent Rack
Manager Lite software.

1. Enter the hostname or IP address of a valid SMTP server, such as a
Microsoft Exchange server, in the SMTP Server field.
2. Enter a valid mailing address in the Username field. This address
displays in the From: field of all sent email messages.
3. Click Save to save the changes.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

4-9

4-10

Compaq Console Management Controller User Guide

To add an address to the email alert list:
1. Type a user’s valid email address in the Email Addresses field.
2. Click Add to add the address to the list.
To remove an address from the email alert list:
1. Highlight the email address you want to remove.
2. Click Remove to remove the address from the list.

Pager Setup Screen

Figure 4-6. Pager Setup screen

Click the Pager Setup link to access the Pager Setup screen. Use this screen
to set the phone numbers to which pager messages can be sent when CMC
alerts occur.
NOTE: The added phone numbers become available on the Alert Handling screen, where
each number must be configured to receive specific alerts. See the section “Alert
Handling Screen,” later in this chapter.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

Software

Before pager alerts can be sent, configure the software to use the modem:
1. Enter the COM port to which the modem is connected in the
CommPort field.
2. Click Save to save the changes.
To add a phone number to the pager alert list:
1. Type a valid phone number for the pager and the Personal Identification
Number (PIN) in the Phone Numbers field. The format is
PHONE *PIN, where PHONE is the phone number for the pager and
PIN is the PIN number, for example, 18003451518 *1234.
2. Click Add to add the phone number to the list.
To remove a phone number from the pager alert list:
1. Highlight the phone number you want to remove.
2. Click Remove to remove the phone number from the list.

Change Password Screen

Figure 4-7. Change Password screen

Click the Change Password link to access the Change Password screen. Use
this screen to change the password used to log in to the software.
NOTE: The software allows only one user. The user is called Administrator.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

4-11

4-12

Compaq Console Management Controller User Guide

To change the password:
1. Type the old password in the Old Password field. If changing the
password for the first time, the old password is Administrator.
2. Type the new password in the New Password field. Passwords must
contain at least eight characters.
NOTE: Passwords can contain 8 to 20 characters. Passwords are case sensitive.

3. Retype the new password in the Retype New Password field.
4. Click Save to save the changes or click Cancel to cancel the changes.

Device Configuration
To configure the individual CMC devices, click the Devices icon in the top
frame of the user interface. The IP addresses of all recognized CMCs display
in the left frame. Click the arrow next to each IP address for an expandable list
of available links for that CMC. The links to the device configuration pages
are as follows:
■

CMC Properties

■

Sensor Setup

■

Accessory Setup

■

Threshold Config

■

Alert Handling

■

Manual Control

■

Log

After a CMC is configured, each device configuration screen available for that
CMC is labeled with the CMC IP address, name, and physical location.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

Software

CMC Properties Screen

Figure 4-8. CMC Properties screen

Click the CMC Properties link to access the CMC Properties screen. Use
this screen to configure the CMC properties for each CMC recognized by the
Intelligent Rack Manager Lite software. The CMC hardware, software,
firmware, and MIB version levels are indicated in the Device Information
box. The availability of updated versions is indicated in the Status column.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

4-13

4-14

Compaq Console Management Controller User Guide

To configure a CMC:
1. Enter the name, physical location, and contact person for the CMC in
the Device Setup box.
2. Select the appropriate display language and temperature unit of measure.
3. Select the audible alarm Off radio button to permanently turn off the
audible alarm.
4. Enable the Press
to Silence Alarm option to be able to silence
audible alarms from the front panel of the CMC.
5. Enter a password specific to this CMC and enable or disable the
password functionality. The CMC password can be up to six characters
in length. Characters can only be capital letters or numbers.
NOTE: If the password is enabled, the password is required to change the CMC
IP address and settings using the front panel controls or a terminal program.

6. Edit the SNMP Read/Write Community strings if necessary.
CAUTION: The SNMP Read/Write Community strings displayed on the CMC
Properties screen must match those on the CMC device. If you edit the strings
on this screen, be sure to make the same changes for the CMC device using a
terminal program as described in “Terminal Program Operation” in this chapter.

7. After entering the CMC properties, click Save to save the changes or
click Cancel to cancel the changes.
8. Click Return to view the Device Home screen for this CMC. The
Device Home screen is discussed in detail later in this chapter.
To update the MIB, software, and firmware for the CMC, click Update.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

Software

Sensor Setup Screen

Figure 4-9. Sensor Setup screen

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

4-15

4-16

Compaq Console Management Controller User Guide

Click the Sensor Setup link to access the Sensor Setup screen. Use this
screen to configure the sensors.
To configure the sensors:
1. Select the Not Available radio button for each sensor that is listed as
available but not installed.
NOTE: For the initial system installation and boot, the CMC automatically recognizes
installed sensors and fans.

2. Set the appropriate fan and lock behavior when smoke is detected.
3. Set the sensitivity of the shock sensor, with 1 being low sensitivity and
10 being high sensitivity. The recommended setting is 5.
4. For Intrusion 1 through 4, enter the sensor description and set the fan
behavior and shock control when doors are opened.
IMPORTANT: For the door-locking feature to work properly, you must assign at least one
intrusion sensor to each lock set. For more information about the door-locking feature,
see “Accessory Setup Screen” in this chapter.

5. Enter the description and logic of sensors installed in Auxiliary 1 and 2.
6. After entering the sensor information, click Save to save the changes or
click Cancel to cancel the changes.
7. Click Return to view the Device Home screen for this CMC. The
Device Home screen is discussed in detail later in this chapter.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

Software

Accessory Setup Screen

Figure 4-10. Accessory Setup screen

Click the Accessory Setup link to access the Accessory Setup screen. Use
this screen to configure the CMC options.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

4-17

4-18

Compaq Console Management Controller User Guide

To configure the options:
1. Select whether each fan is installed (available) or not installed
(unavailable).
2. Select the appropriate logic for the alarm relays.
3. Enable the Press
to Deactivate Relay option to be able to
deactivate relay output from the front of the CMC.
4. Select the appropriate options for each lock set.
a. Select whether each lock set is installed (available) or not installed
(unavailable).
b. Select the doors and panels that must be closed before the lock set
can activate the lock.
IMPORTANT: For the door-locking feature to work properly, you must assign at least one
intrusion sensor to each lock set. For more information about configuring intrusion
sensors, see “Sensor Setup Screen” in this chapter.

c. Set the lock sets to remain locked or to unlock in the event of each
listed fault. Enable the concealed door release to press a hidden
switch to manually unlock locked doors.
NOTE: The software cannot detect the concealed door release. Make sure the concealed
door release option is not selected for CMCs that control racks without a concealed door
release.

5. After entering the accessory information, click Save to save the changes
or click Cancel to cancel the changes.
6. Click Return to view the Device Home screen for this CMC. The
Device Home screen is discussed in detail later in this chapter.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

Software

Threshold Configuration Screen

Figure 4-11. Threshold Configuration screen

Click the Threshold Config link to access the Threshold Configuration
screen. Use this screen to modify the minimum and maximum acceptable
values for temperature, humidity, and voltage.
To modify the values:
1. Enter the minimum and maximum temperature, humidity, and voltage
values.
2. Enter the temperatures at which warnings are issued.
3. Enter the temperatures at which fans turn on and the degree of
temperature drop that must be achieved before fans turn off.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

4-19

4-20

Compaq Console Management Controller User Guide

4. After entering the threshold information, click Save to save the changes
or click Cancel to cancel the changes.
5. Click Return to view the Device Home screen for this CMC. The
Device Home screen is discussed in detail later in this chapter.

Alert Handling Screen

Figure 4-12. Alert Handling screen

Click the Alert Handling link to access the Alert Handling screen. Use this
screen to choose how the software will issue each type of alert for each CMC.
Alarms can be issued by message, pager, email, audible alarm, switch alarm
relay 1, or switch alarm relay 2.
To set the behavior for each type of alert:
1. Select an alert situation from the pull-down menu.
2. Select the appropriate type of alert for that situation.
3. Click Save to save the changes.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

Software

4. Repeat steps 1 through 3 for each alert situation in the pull-down menu.
5. Click Return to view the Device Home screen for this CMC. The
Device Home screen is discussed in detail later in this chapter.
NOTE: Computer names, email addresses, and phone numbers that display on the Alert
Handling screen can be set using the software settings screens.

Manual Control Screen

Figure 4-13. Manual Control screen

Click the Manual Control link to access the Manual Control screen. Use this
screen to manually control fan, door-locking, and alarm relay behaviors.
NOTE: Only enabled fans and enabled lock sets display on the Manual Control screen.
To enable fans and lock sets, see “Accessory Setup Screen” in this chapter.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

4-21

4-22

Compaq Console Management Controller User Guide

To manually control the behaviors:
1. Select the appropriate radio button to manually turn fans on or off.
2. Lock a door that is unlocked or unlock a door that is locked. Doors can
be unlocked after a specified amount of time has passed, immediately,
or manually by activating the concealed door release.
NOTE: Activating the concealed door release on the Manual Control screen allows the
door to be unlocked using a hidden switch one time. After the door is closed, the door
locking feature automatically locks the door and the concealed door release option is
disabled. To permanently enable the concealed door release, see “Accessory Setup
Screen” in this chapter.

3. Deactivate alarm relays as necessary. Alarm relays are only available
after they are activated by an alarm. The alarm relay logic is set up on
the Accessory screen.
4. Click Save to save the changes.
5. Click Return to view the Device Home screen for this CMC. The
Device Home screen is discussed in detail later in this chapter.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

Software

Log Screen

Figure 4-14. Log screen

Click the Log link to access the Log screen. Use this screen to view
information about alerts issued for the CMC.
■

Click Clear to clear all entries in the log.

■

Click Return to view the Device Home screen for this CMC.

■

Click Print on the browser window to print the log.

Device Monitoring
After the software and each recognized CMC are configured, monitor the
CMC device status with the following:
■

Active Alarms Screen

■

Device Home Screen

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

4-23

4-24

Compaq Console Management Controller User Guide

Active Alarms Screen

Figure 4-15. Active Alarms screen

Click the Devices icon, then click the CMC Devices heading in the left frame
to access the Active Alarms screen. The Active Alarms screen automatically
displays each time you log in to the software. Use this screen to view a
summary of all active alarms and status information for all CMC devices. This
information automatically updates every 15 seconds, or you can update the
information at any time by clicking the Refresh link.
Click the IP address of a CMC in the list to display the Device Home screen
and view details for that device.
Table 4-1 lists the meanings of the status symbols used on the Active Alarms
screen.

Table 4-1
Active Alarms Status Symbols
Symbol

Meaning
Normal
Minor
Major
Critical

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

Software

Device Home Screen

Figure 4-16. Device Home screen

The Device Home screen can be accessed by:
■

Clicking an IP address in the Active Alerts screen status list.

■

Clicking the IP address of a CMC in the left frame of the software
interface.

■

Clicking Return at the bottom of any device configuration screen.

Use this screen to view status information about individual CMC devices. The
Device Home screen contains the following:
■

CMC IP address, designation, and physical location

■

A Refresh link

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

4-25

4-26

Compaq Console Management Controller User Guide

■

■

Temperature, humidity, and voltage information in numerical and
graphical form, including an indication of whether the temperature is in
a safe range:
G

White—Safe range

G

Yellow—Warning

G

Red—Critical

G

Gray—No sensor

Component status information. Table 4-2 lists the meanings of the status
symbols used on the Device Home screen.

Table 4-2
Device Home Status Symbols
Symbol

Meaning
Informational
Minor
Major
Critical

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

Software

Terminal Program Operation
Much of the Intelligent Rack Manager Lite software functionality is available
in a simpler, text-based interface using a host computer and a terminal
program over a serial connection to the CMC. See “Configuring the CMC” in
Chapter 2 of this guide for more information on connecting the CMC to a host
computer.
The serial link:
■

Provides some additional functionality that lets you configure the CMC
for operation with other SNMP managers. This feature is not needed for
Intelligent Rack Manager Lite-only systems.
IMPORTANT: Up to four Compaq Intelligent Rack Manager Lite consoles or other trap
monitors can be specified to receive alerts. The first trap receiver is always reserved for
the last Compaq Intelligent Rack Manager Lite management console that accessed the
CMC device. Compaq Intelligent Rack Manager Lite and other trap monitors, such as
Compaq Insight Manager XE, cannot be loaded on the same server.

■

Can be used to flash the memory with new CMC software. This
operation is normally performed using the Intelligent Rack Manager
Lite software over the network.

Starting HyperTerminal
HyperTerminal is a terminal program that is included with Microsoft operating
systems. To start HyperTerminal:
1. Select Start, Programs.
2. Select Accessories and click HyperTerminal.
3. Do one of the following:
G

For Windows NT 4.0, click HyperTerminal.

G

For Windows 2000, click Communications, then click
HyperTerminal.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

4-27

4-28

Compaq Console Management Controller User Guide

4. Set up the properties for your terminal connection:
a. Enter a name for your connection in the New Connection dialog
box. Select an icon to represent the connection, then click OK. The
Phone Number dialog box displays.
b. In the Connect Using field, select Direct Connection to the COM
port to which the CMC is connected, then click OK. The Properties
dialog box displays.
c. Enter the following port settings, then click OK.
Bits per second (baud rate)

9600

Data bits

8

Parity

None

Stop bits

1

Flow control

None

5. The main menu of the CMC displays on the HyperTerminal interface.

Navigating Menus
CAUTION: All configuration changes made in a terminal program are retained in
CMC memory. If you change the Read and Write Community strings in the
terminal program setup independently from the Compaq Intelligent Rack
Manager Lite software, the software can no longer control the CMC.

Use Table 4-3 as a reference when navigating the CMC menus.
■

To change values in HyperTerminal, type the new value in the field and
press Enter.

■

To select and toggle values, press the spacebar.

■

To save changes and jump back to the previous menu, press Esc.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

Software

4-29

Table 4-3
CMC Terminal Program Menus
Main Menu Items

Submenu 1 Items

Submenu 2 Items

Brief Description

Values

Display rack information.

Status

Display rack status.

Network
configuration
IP configuration
IP Address
IP Subnetmask
IP Router

Set network addresses.

Trap receiver
configuration
IP Trap receiver
Enable/Disable
IP Trap receiver
Enable/Disable
IP Trap receiver
Enable/Disable
IP Trap receiver
Enable/Disable

Set up to 4 trap receiver IP
addresses. Trap receiver
number 1 is dedicated to
the Compaq Intelligent
Rack Manager software.
Any IP address entered in
number 1 will be over
written when used with the
software.

SNMP Manager
SNMP Manager
SNMP Manager
SNMP Manager
SNMP Manager
SNMP Manager
SNMP Manager
SNMP Manager
SNMP Manager
SNMP Manager
SNMP Manager
SNMP Manager

Set the authorized IP
addresses of the
management computers.
In the default setting (all
addresses set to 0.0.0.0),
all network IP addresses
are SNMP-authorized. If
one or more IP addresses
are entered, only those IP
addresses have SNMP
authorization. SNMP
communication with the
CMC can only be
established from this
system.

SNMP IP Access

continued

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

4-30

Compaq Console Management Controller User Guide

Table 4-3
CMC Terminal Program Menus continued
Main Menu Items

Submenu 1 Items

Submenu 2 Items

Brief Description

Network
configuration
(continued)

Enable TFTP
Enable Auth. Traps
Read Community
Write Community
System Name
System Contact
System Location
Change Password
Enable Password
Activate actual values

Set network properties. All
configuration changes are
retained in CMC memory.
Changing the Read or
Write Community strings
independent of the
software prevents the
software from being able
to control the CMC. If
Enable TFTP is disabled,
the Compaq Intelligent
Rack Manager software
will not be able to perform
firmware upgrades.

Language
Temperature unit
Audible Alarm
Quit Alarm relay 1
Quit Alarm relay 2
Logic Alarm relay 1
Logic Alarm relay 2
Set date of internal clock
Set time of internal clock

Configure general CMC
properties.

General setup

Setup Detectors
(Analog/Fans)

Set up sensors.
Temperature 1 available
Temperature 2 available
Fan1 available
Fan2 available
Voltage available
Humidity available
continued

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

Software

4-31

Table 4-3
CMC Terminal Program Menus continued
Main Menu Items

Submenu 1 Items

Submenu 2 Items

Setup Detectors
(Digital)

Brief Description
Set up sensors.

Input 1
Available
Description
Fan option
Shock option
Input 2
Available
Description
Fan option
Shock option
Input 3
Available
Description
Fan option
Shock option
Input 4
Available
Description
Fan option
Shock option
Smoke sensor
Available
Fan option
Shock sensor
Available
Sensibility
continued

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

4-32

Compaq Console Management Controller User Guide

Table 4-3
CMC Terminal Program Menus continued
Main Menu Items

Submenu 1 Items

Setup Detectors
(Digital)
(continued)

Aux 1

Submenu 2 Items

Brief Description

Available
Description
Logic
Aux 2
Available
Description
Logic
Thresholds

Sets threshold values.
Warning temp.1
Max.temp.1
Min.temp.1
Warning temp.2
Max.temp.2
Min.temp.2
Fan 1
Setpoint Fan 1
Hysteresis Fan 1
Fan 2
Setpoint Fan 2
Hysteresis Fan 2
Temperature unit
Max.voltage
Min.voltage
Max.humidity
Min.humidity
continued

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

Software

4-33

Table 4-3
CMC Terminal Program Menus continued
Main Menu Items

Submenu 1 Items

Submenu 2 Items

Alert handling

Brief Description
Configure alert handling.

Temperature 1
Alarm relays max
Alarm relays warning
Alarm relays min
Audible Alarm max
Audible Alarm warning
Audible Alarm min
Temperature 2
Alarm relays max
Alarm relays warning
Alarm relays min
Audible Alarm max
Audible Alarm warning
Audible Alarm min
Fan 1
Alarm relays
Audible Alarm
Fan 2
Alarm relays
Audible Alarm
Voltage
Alarm relays max
Alarm relays min
Audible Alarm max
Audible Alarm min
Humidity
Alarm relays max
Alarm relays min
Audible Alarm max
Audible Alarm min
continued

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

4-34

Compaq Console Management Controller User Guide

Table 4-3
CMC Terminal Program Menus continued
Main Menu Items

Submenu 1 Items

Alert handling
(continued)

Aux 1

Submenu 2 Items

Brief Description

Alarm relays
Audible Alarm
Aux 2
Alarm relays
Audible Alarm
Display system data and
network addresses.

System Info
Defaults
Set thresholds to default
Set setup to default

Revert settings to default
values.

Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

Chapter

5

Troubleshooting

This chapter provides information on the following topics:
■

Troubleshooting during startup

■

Troubleshooting after startup

■

Repairing the CMC

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: f-ch5 Troubleshooting.doc Last Saved On: 6/20/01 8:48 PM

5-2

Compaq Console Management Controller User Guide

Troubleshooting During Startup
If problems occur when starting the Compaq CMC, select the appropriate
symptom for possible causes and actions.

Table 5-1
Troubleshooting Guide (CMC Startup)
Description of Fault Symptom

Solution

The CMC fails to function after
power up.

Check the AC power connection.

Connected sensors are not
recognized by the CMC.

Make sure unit is On.
Make sure sensor is connected to correct port on
the rear of the CMC.
Check the cables to the sensors for cable breaks.
If applicable, check the power supply to the
sensors.

Alarm signals are only indicated on
the CMC but not at the console
management.

Verify network connection is correctly installed.
Verify the correct IP address is programmed into
the unit.
Contact network administrator.

There is no shock alarm, despite
the presence of vibrations.

Use software to adjust sensitivity. See Chapter 4.

Intrusion alarms do not activate
when door is opened.

Verify intrusion magnetic switches are properly
installed.
Verify sensors connected to the correct port on the
rear of the unit.

Faults are not reported although
sensors are connected.

The interface LEDs are not giving
any signals.

Check the sensors for correct installation.
Verify that sensors are connected to the proper
port on the rear of the unit.
Check the connection to the network.
Contact network administrator.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: f-ch5 Troubleshooting.doc Last Saved On: 6/20/01 8:48 PM

Troubleshooting

Troubleshooting After Startup
For problems that occur after the CMC started, these suggested actions address
possible causes.

Table 5-2
Troubleshooting Guide (After Startup)
Symptom

Possible Cause

Suggested Action

Audible Alarm

Alarm condition exists.

Check display or console for
error condition and clear.

Repairing the CMC
Repairs to the CMC must be carried out by Compaq or a Compaq authorized
service representative. The only user-serviceable parts are the fuses located in
the rear of the unit. If the fuses have opened, verify that the condition that
caused the fault has been cleared. Replace the fuse with the exact rating as
specified on the unit label. Contact your Compaq authorized service
representative for more details.
WARNING: Disconnect all power cords before servicing the unit.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: f-ch5 Troubleshooting.doc Last Saved On: 6/20/01 8:48 PM

5-3

Appendix

A

Regulatory Compliance Notices

Regulatory Compliance
Identification Numbers
For the purpose of regulatory compliance certifications and identification, the
Compaq CMC model is assigned a Compaq Series Number. The Compaq
Series Number for this product is shown in the following table. The CMC
Series Number can be found on the Regulatory Compliance label, along with
the required approval markings and information. The Regulatory Compliance
label is located on the top of the CMC unit. When requesting certification
information for this product always refer to this series number. This series
number should not be confused with the marketing name or model number for
your Compaq CMC.

Table A-1
Compaq CMC Series Number
Series Number
EO3009

CMC Model
Worldwide model - 100 to 240V

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: g-appa Regulatory Compliance Notices.doc Last Saved On: 6/20/01 7:33 PM

A-2

Compaq Console Management Controller User Guide

Federal Communications
Commission Notice
Part 15 of the Federal Communications Commission (FCC) Rules and
Regulations has established Radio Frequency (RF) emission limits to provide
an interference-free radio frequency spectrum. Many electronic devices,
including computers, generate RF energy incidental to their intended function
and are, therefore, covered by these rules. These rules place computers and
related peripheral devices into two classes, A and B, depending upon their
intended installation. Class A devices are those that may reasonably be
expected to be installed in a business or commercial environment. Class B
devices are those that may reasonably be expected to be installed in a
residential environment (that is, personal computers). The FCC requires
devices in both classes to bear a label indicating the interference potential of
the device as well as additional operating instructions for the user.
The rating label on the device shows which class (A or B) the equipment falls
into. Class B devices have an FCC logo or FCC ID on the label. Class A
devices do not have an FCC logo or FCC ID on the label. Once the class of the
device is determined, refer to the following corresponding statement.

Class A Equipment
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference
to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference, in which case the user will be required to
correct the interference at personal expense.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: g-appa Regulatory Compliance Notices.doc Last Saved On: 6/20/01 7:33 PM

Regulatory Compliance Notices

Class B Equipment
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
■

Reorient or relocate the receiving antenna.

■

Increase the separation between the equipment and receiver.

■

Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.

■

Consult dealer or experienced radio or television technician for help.

Declaration of Conformity for Products Marked
with the FCC logo - United States Only
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
■

For questions regarding your product, contact:
Compaq Computer Corporation
P. O. Box 692000, Mail Stop 530113
Houston, Texas 77269-2000
1
or call 1-800-652-6672 (1-800-OK COMPAQ) .

■

For questions regarding this FCC declaration, contact:
Compaq Computer Corporation
P. O. Box 692000, Mail Stop 510101
Houston, Texas 77269-2000
or call (281) 514-3333.

To identify this product, refer to the Part, Series, or Model number found on
the product.

1

For continuous quality improvement, calls may be recorded or monitored.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: g-appa Regulatory Compliance Notices.doc Last Saved On: 6/20/01 7:33 PM

A-3

A-4

Compaq Console Management Controller User Guide

Modifications
The FCC requires the user to be notified that any changes or modifications
made to this device that are not expressly approved by Compaq Computer
Corporation may void the user's authority to operate the equipment.

Canadian Notice (Avis Canadien)
Class A Equipment
This Class A digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du
Règlement sur le matériel brouilleur du Canada.

Class B Equipment
This Class B digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du
Règlement sur le matériel brouilleur du Canada.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: g-appa Regulatory Compliance Notices.doc Last Saved On: 6/20/01 7:33 PM

Regulatory Compliance Notices

European Union Notice
Products with the CE Marking comply with both the EMC Directive
(89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the
Commission of the European Community.
Compliance with these directives implies conformity to the following
European Norms (in brackets are the equivalent international standards):
■

EN50091-1 – CMC Product Safety Requirements

■

EN50091-2 – CMC EMC Requirements

Japanese Notice
July 14 version

China Taiwan Notice

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: g-appa Regulatory Compliance Notices.doc Last Saved On: 6/20/01 7:33 PM

A-5

Appendix

B

Electrostatic Discharge

To prevent damaging the system, be aware of the precautions you need to
follow when setting up the system or handling parts. A discharge of static
electricity from a finger or other conductor may damage system boards or
other static-sensitive devices. This type of damage may reduce the life
expectancy of the device.
To prevent electrostatic damage, observe the following precautions:
■

Avoid hand contact by transporting and storing products in static-safe
containers.

■

Keep electrostatic-sensitive parts in their containers until they arrive at
static-free workstations.

■

Place parts on a grounded surface before removing them from their
containers.

■

Avoid touching pins, leads, or circuitry.

■

Make sure you are always properly grounded when touching a
static-sensitive component or assembly.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: h-appb Electrostatic Discharge.doc Last Saved On: 6/20/01 7:36 PM

B-2

Compaq Console Management Controller User Guide

Grounding Methods
There are several methods for grounding. Use one or more of the following
methods when handling or installing electrostatic-sensitive parts:
■

Use a wrist strap connected by a ground cord to a grounded workstation
or computer chassis. Wrist straps are flexible straps with a minimum of
1 megohm ±10 percent resistance in the ground cords. To provide
proper ground, wear the strap snug against the skin.

■

Use heel straps, toe straps, or boot straps at standing workstations. Wear
the straps on both feet when standing on conductive floors or dissipating
floor mats.

■

Use conductive field service tools.

■

Use a portable field service kit with a folding static-dissipating work
mat.

If you do not have any of the suggested equipment for proper grounding, have
a Compaq authorized reseller install the part.
NOTE: For more information on static electricity, or assistance with product installation,
contact your Compaq authorized reseller.

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: h-appb Electrostatic Discharge.doc Last Saved On: 6/20/01 7:36 PM

Appendix

C

Specifications

This appendix provides specifications that apply to the Compaq CMC:
■

Physical specifications

■

Environmental specifications

■

Input/Output specifications

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: i-appc Specifications.doc Last Saved On: 6/20/01 7:39 PM

C-2

Compaq Console Management Controller User Guide

Specifications
Table C-1
Specifications – Console Management Controller (CMC)
Feature

Dimensions

Specification
U.S.

Metric

Height

1.75 in (1U)

44.5 mm

Depth

4.13 in

105 mm

Width

19 in

483 mm

Operating
temperature

+10°C to +50°C

Storage
temperature

-20°C to +60°C

Processor

AM186 based (20 MHz), 16-bit CPU, Intel-compatible

RAM

512KB 16-bit DRAM

Program memory

512KB flash-EPROM

CMC Rated
voltage

100 VAC to 240 VAC, 50/60 Hz

CMC Maximum
input current
rating

300mA

Voltage drop time

10 ms (maximum)

Rated voltage for
fan inlet/outlets

100 VAC to 240 VAC, 50/60 Hz

Maximum current
rating for fans

Fan inlet - 4A
Fan outlet - 2A (each)
continued

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: i-appc Specifications.doc Last Saved On: 6/20/01 7:39 PM

Specifications

Table C-1
Specifications – Console Management Controller (CMC) continued
Feature

Specification

Serial interface

RS-232

Ethernet connection

10BaseT, IEEE 802.3 (10 MB/sec), TCP/IP, SNMP, TFTP

Fuses

Main AC input power-250V, 800mA, T, IEC-127
Fan #1 switched power-250V, 2A, T, IEC-127
Fan #2 switched power-250V, 2A, T, IEC-127

Alarm relays 1 and 2

Contacts: S.P.D.T., 800 mA @ 24VDC

Maximum DC output
(Alarm relay ports)

160 mA @ 24VDC (See Appendix D)

Displays

4 LEDs, LCD display (2 lines x 20 characters)

Audible Alarm

Piezoelectric signal generator

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: i-appc Specifications.doc Last Saved On: 6/20/01 7:39 PM

C-3

Appendix

D

Pin Layout Configuration

Compaq CMC
The RJ-12 connector pins on the rear of the CMC are identified in the following figure. The
RJ-12 pin functions are described in Table D-1.

1

6

Figure D-1. RJ-12 ports

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller Comments:
Part Number: 218258-002 File Name: j-appd Pin Layout Configuration.doc Last Saved On: 6/20/01 7:01 PM

D-2

Compaq Console Management Controller

Alarm Relay Wiring Examples

Figure D-2. Alarm relay wiring examples

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller Comments:
Part Number: 218258-002 File Name: j-appd Pin Layout Configuration.doc Last Saved On: 6/20/01 7:01 PM

Pin Layout Configuration

Table D-1
RJ-12 Pin Layout Specifications
Pin

Temperature
sensor

Humidity sensor

Discrete
inputs

Smoke sensor

Alarm relays

1

Sensor

Humidity signal (4mA to
20mA)

Contact of
3
sensor

Contact of sensor

Contact NC

2

Sensor

Ground (4mA to 20mA)

Contact of
3
sensor

Contact of sensor

Contact C

3

-

-

-

-

Contact NO

4

-

-

-

-

-

5

-

Ground

-

Ground

Ground

6

-

24VDC, 44mA

24VDC, 160 mA

24VDC, 160mA

1

1

1

Note: 1. The alarm relay contacts are rated for a maximum of 24VDC and 800mA, when connecting to an external
power source.
2. The CMC can supply up to 160mA to users from its internal 24VDC power supply via the two alarm relay
ports. The 160mA can be split as needed between the two ports.
3. Intrusion sensors can be connected to Auxiliary 1 and 2 input ports to allow monitoring additional doors.
Users may also wire a simple switch closure device between pins 1 and 2. Pin 2 is connected to the CMC
signal ground and pin 1 is connected to the CMC signal input. Opening or closing the switch will trigger an
alarm, as configured in the software setup.

2

D-3

Index

A
accessing
HyperTerminal 4-26
LCD menu items 3-2
software 4-4
Accessory Setup screen 4-16
Active Alarms screen 4-23
Add/Remove Device screen 4-7
adding
addresses for email alerts 4-10
CMCs to software 4-7
computer names for popup
alerts 4-8
phone numbers for pager
alerts 4-11
address, IP 3-5
Alarm LED 1-5, 1-6
alarm relays
activating 3-6
controlling manually 4-20
deactivating 3-7
setting logic 4-17
alarms
active 4-23
setting actions 3-6, 4-20
silencing 3-7, 4-14
status 1-6
turning off 4-14
viewing 4-23
Alert Handling screen 4-19

alert messages
email 3-6, 4-9
pager 3-6, 4-10
popup 3-6, 4-8
alert thresholds 4-18
alerts
example situation 3-6
handling 3-6, 4-19
audible alarm
how to respond 5-3
silencing 3-7, 4-14, 4-17
turning off 4-14
auxiliary sensors 3-3, 4-16

B
buttons
Enter/Alarm Silence 1-5
Escape 1-5
Power 1-5, 2-20
Scroll Up 1-5

C
cables
extension 2-21
network 2-22
retaining 2-17
securing 2-22
Canadian Notice (Avis
Canadien) A-4
capabilities, software 1-4

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: x-index.doc Last Saved On: 6/20/01 3:10 AM

2

Compaq Console Management Controller User Guide

CD, software 4-3
CE Marking A-5
Change Password screen 4-11
CMC See Console Management
Controller
CMC Properties screen 4-13
Comm Port See communications
port
communications port
features 1-4
overview 1-4
community strings 4-14
Compaq authorized reseller x
Compaq Intelligent Rack Manager
Lite See software
concealed door release 4-17
configuring
alerts 3-6, 4-19
CMCs 2-24, 4-12, 4-13
mail system 4-9
modem 4-11
options 4-16
sensors 4-15
software 4-6
threshold values 4-18
connecting
cord retention bracket 2-17
network 2-22
power cable 2-20
rack fan array 2-19
sensors 2-18
UPSs 2-21
utility power 2-21
Console Management Controller
adding to software 4-7
basic configuration 4-1
configuring 2-24, 4-12
connecting sensors 2-18
front panel 1-5
general description 1-2
installation requirements 2-2
installing 2-7
model 1-2
monitoring 4-22
overview 1-1
properties 4-13

rear panel 1-7, 2-18
removing from software 4-7
specifications C-1
standard features 1-3
viewing status 4-24
contact
selecting 4-14
viewing 3-4
contents, kit 2-2
control buttons 3-2
controlling fans 4-20
cord retention bracket,
connecting 2-17
current, input C-2

D
deactivating relays 3-7
Declaration of Conformity A-3
default password 4-5
depth C-2
device configuration links 4-12
Device Home screen 4-24
dimensions C-2
disabling
alarms 4-14
passwords 3-5, 4-14
shock sensors 4-15
display
language 4-14
LCD 1-5
door-locking feature 4-20
doors, unlocking 3-6, 4-20
drop time, voltage C-2

E
electric shock symbol viii
email
addresses 4-10
alert messages 3-6, 4-9
mail system setup 4-9
system requirements 4-2
Email Setup screen 4-9
enabling
alarms 4-14

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: x-index.doc Last Saved On: 6/20/01 3:10 AM

Index

passwords 3-5, 4-14
shock sensors 4-15
Enter/Alarm Silence button 1-5
Escape button 1-5
Ethernet
connection C-3
European Union Notice A-5
example, alert handling 3-6
extension cables 2-21

F
fans
availability 4-17
connecting 2-19
controlling manually 4-20
maximum current rating C-2
power 2-21
setting up 3-5, 4-17
status 3-3, 4-24
features
communications port 1-4
Console Management
Controller 1-3
front panel 1-5
rear panel 1-7
software 1-4
Federal Communications
Commission (FCC) notice
cables A-4
FCC Class A compliance A-2
FCC Class B compliance A-3
firmware
updating 4-14
version 3-4, 4-13
frames 4-6
front panel
controls 1-5
LEDs 1-6
fuses
replacing 5-3
specifications C-3

G
general description 1-2

getting help x
Grounding Methods B-2

H
hardware
kit contents 2-2
version 3-4, 4-13
hazard symbol viii
hazardous energy circuits
symbol viii
height C-2
help
additional sources x
Compaq authorized resellers x
Compaq website x
online 4-6
technical support telephone
numbers x
hidden switch 4-17
humidity
installing sensors 2-12
sensor 1-8, 2-12
sensor setup 4-15
status 3-3, 4-25
threshold settings 4-18
HyperTerminal 4-26
hysteresis 4-18

I
icon
electric shock viii
exclamation point viii
screwdriver viii
software 4-6
telephone ix
warning viii
information
status 3-3, 4-25
system 3-4, 4-13
input current rating C-2
inputs
status 3-3
installation
overview 2-1

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: x-index.doc Last Saved On: 6/20/01 3:10 AM

3

4

Compaq Console Management Controller User Guide

procedures 2-7
requirements 2-2
tools needed 2-6
installing
CMCs 2-7
humidity sensor 2-12
intrusion sensors 2-9
optional sensors 2-11
sensors 2-8
shock sensor 2-13
smoke sensors 2-14
software 4-3
temperature sensors 2-8
Intelligent Rack Manager Lite See
software
interface
serial C-3
software 4-6
internal temperature 1-3, 3-3
intrusion sensors
installing 2-9, 2-11
setting up 4-16
IP address, setting 2-24, 3-5
IP mask, setting 3-5
IP router, setting 3-5

J
Japanese Notice A-5

K
kit
contents 2-2
door locking 2-16
items not included 2-6
optional sensors 2-4

L
language
display
setting
LCD
display
menus

4-14
2-24, 3-5
1-5
3-2

LEDs 1-5, 1-6
links
device configuration 4-12
device monitoring 4-22
software setup 4-6
lists
alert situations 4-19
computer names 4-8
email addresses 4-10
pager numbers 4-11
recognized CMCs 4-7
locating system information 3-4
location
selecting 4-14
system 3-4
lock sets
assigning intrusion
sensors 4-16
controlling manually 4-20
installing 2-16
Log screen 4-22
logic, alarm relays 4-17
Login screen 4-5
logs
clearing 4-22
printing 4-22

M
mail system, configuring 4-9
maintaining smoke sensors 2-16
managing
CMCs 4-1
CMCs remotely 4-4
Manual Control screen 4-20
mask, IP 3-5
memory
program C-2
RAM C-2
menus
changing values 3-5
LCD 3-2
Setup 3-5
Status 3-3
System Information 3-4
terminal 4-27

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: x-index.doc Last Saved On: 6/20/01 3:10 AM

Index

messages
email alert 4-9
pager alert 4-10
popup alert 4-8
Messaging Setup screen 4-8
MIB
file 4-1
version 3-4, 4-13
modem, configuring 4-11
modifying
accessory setup 4-16
alert handling 3-6, 4-19
CMC properties 4-13
menu values 3-5
sensor setup 4-15
threshold values 4-18
monitoring CMC devices 4-22
mounting CMCs 2-23

N
name
selecting 4-14
viewing 3-4
navigating
LCD menus 3-2
software 4-6
terminal menus 4-27
network
cable 2-22
connecting 2-22
LED 1-5
number
part 1-2
series A-1

O
operating
temperature C-2
time 3-4
optional sensors
installing 2-11
kit 2-4
options, configuring 4-16
overview

CMC 1-1
communications port 1-4
installation 2-1
operating the CMC 3-1
software 1-4
specifications C-1
troubleshooting 5-1

P
pager
alert messages 3-6, 4-10
numbers, entering 4-11
system requirements 4-2
Pager Setup screen 4-10
panels
front 1-5
rear 1-7, 2-18
part number 1-2
passwords
changing 4-11
default 4-5
enabling/disabling 3-5, 4-14
requirements 4-12
physical specifications C-2
popup alert messages 3-6, 4-8
ports
communications 1-4
serial 1-4, 1-5, 2-25
power
button 1-5
connecting 2-20
cords 2-6
fans 2-21
utility, connecting 2-21
powering on the CMC 2-23
preinstallation tasks 4-2
printing logs 4-22
problems See troubleshooting
processor C-2
program
memory C-2
terminal 4-26
properties, CMC 4-13

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: x-index.doc Last Saved On: 6/20/01 3:10 AM

5

6

Compaq Console Management Controller User Guide

R
rack
mounting CMCs 2-23
stability ix
RAM C-2
rated voltage C-2
Read/Write Community
strings 4-14
rear panel 2-18
recognized CMCs 4-7
reference material 2-3
Regulatory Compliance
identification A-1
location of label A-1
series numbers A-1
relays See alarm relays
remote management 4-4
removing
addresses for email alerts 4-10
CMCs from software 4-7
computer names for popup
alerts 4-8
phone numbers for pager
alerts 4-11
software from system 4-4
repairing the CMC 5-3
replacing fuses 5-3
reports 4-22
requirements
installation 2-2
installation tools 2-6
password 4-12
system 4-2
RJ-45 receptacle symbol ix
router, IP 3-5

S
safety information ix
screens
Accessory Setup 4-16
Active Alarms 4-23
Add/Remove Device 4-7
Alert Handling 4-19
Change Password 4-11

CMC Properties 4-13
Device Home 4-24
Email Setup 4-9
Log 4-22
Login 4-5
Manual Control 4-20
Messaging Setup 4-8
Pager Setup 4-10
Sensor Setup 4-15
Threshold Configuration 4-18
screwdriver symbol viii
Scroll Up button 1-5
securing cables 2-22
selecting
accessory setup
information 4-16
alert behaviors 4-19
contact person 4-14
device name 4-14
location 4-14
sensor setup information 4-15
temperature unit of
measure 4-14
Sensor Setup screen 4-15
sensors
auxiliary 3-3, 4-16
configuring 4-15
connecting 2-18
humidity 1-8, 4-15
installing 2-8
intrusion 2-9, 4-16
monitoring capabilities 1-2
optional 2-4, 2-11
shock 4-15
smoke 4-15
temperature 1-8, 4-15
voltage 4-15
serial
interface C-3
number 4-13
port 1-5, 2-25
Serial Communication LED 1-5
series number A-1
setting
acceptable values 4-18
alarm actions 4-20

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: x-index.doc Last Saved On: 6/20/01 3:10 AM

Index

IP address 2-24, 3-5
IP mask 3-5
IP router 3-5
language 2-24, 3-5
subnet mask 2-25
setting up
accessories 4-16
alarm relays 4-17
alerts 3-6, 4-19
email alerts 4-9
fans 3-5, 4-17
mail system 4-9
manual control 4-20
pager alerts 4-10
popup alerts 4-8
sensors 4-15
software 4-6
setup links 4-6
Setup menu 3-5
shock sensor
installing 2-13
setting sensitivity 4-15
status 3-3
silencing audible alarms 3-7, 4-14,
4-17
smoke sensor
installing 2-14
maintenance 2-16
operation 2-15
setting logic 4-15
status 3-3
SNMP
basic configuration 4-1
community strings 4-14
software
accessing 4-4
CD 4-3
frames 4-6
general description 1-2
icons 4-6
installing 4-3
interface 4-6
kit contents 2-3
links 4-6
logging in 4-5
password 4-5, 4-11

preinstallation tasks 4-2
screen layout 4-5
setting up 4-6
system requirements 4-2
uninstalling 4-4
version 3-4, 4-13
specifications
overview C-1
physical C-2
standard features 1-3
starting HyperTerminal 4-26
status
LCD menu items 3-3
overview 4-24
reports 4-22
summary 4-23, 4-25
symbols 4-23, 4-25
Status menu 3-3
storage temperature C-2
strings, community 4-14
subnet mask, setting 2-25
switch, hidden 4-17
symbols
in text viii
on equipment viii
status 4-23, 4-25
system
contact 3-4, 4-14
location 3-4, 4-14
name 3-4, 4-14
requirements 4-2
time 3-4
System Information menu 3-4

T
China Taiwan Notice A-5
tasks, preinstallation 4-2
telephone
numbers x
symbol ix
temperature
installing sensors 2-8, 2-11
operating C-2
sensor setup 4-15
sensors 1-8

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: x-index.doc Last Saved On: 6/20/01 3:10 AM

7

8

Compaq Console Management Controller User Guide

status 3-3, 4-25
storage C-2
threshold settings 4-18
unit of measure 3-5, 4-14
terminal operation 4-26
text conventions vii
Threshold Configuration
screen 4-18
time
operating 3-4
system 3-4
tools 2-6
troubleshooting
after start 5-1, 5-3
audible alarm sounds 5-3
connected sensors not
recognized 5-2
during start 5-1, 5-2
faults are not reported, sensors
are connected 5-2
interface LEDs are not giving
any signals 5-2
intrusion alarms do not activate
when door is opened 5-2
no alarm indicated on
management console 5-2
no shock alarm, despite
vibration 5-2
overview 5-1
unit fails to function after
power on 5-2

U
uninstalling software 4-4
units of measure, temperature 3-5,
4-14
unlocking doors 3-6, 4-20
updating firmware 4-14
UPS, connecting 2-21
user interface 4-5

utility power, connecting 2-21

V
values, threshold 4-18
VCCI Notice for Japan A-5
version
firmware 3-4, 4-13
hardware 3-4, 4-13
MIB 3-4, 4-13
software 3-4, 4-13
vibration sensors See shock
sensors
viewing
active alarms 4-23
CMC status 4-24
system information 3-4, 4-13
voltage
drop time C-2
rated C-2
sensor setup 4-15
status 3-3, 4-25
threshold settings 4-18

W
warnings
electric shock viii
hot surfaces ix
network interface
connection ix
RJ-45 receptacle ix
width C-2
www.compaq.com. x

X
Xmodem 1-4

Compaq Confidential – Need to Know Required
Writer: A. J. Scheckelhoff Project: Compaq Console Management Controller User Guide Comments:
Part Number: 218258-002 File Name: x-index.doc Last Saved On: 6/20/01 3:10 AM



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Copy, Fill forms, Extract, Assemble, Print high-res
Modify Date                     : 2002:12:10 15:24:39-06:00
Create Date                     : 2001:07:25 09:50:12-05:00
Page Count                      : 108
Page Mode                       : UseOutlines
Page Layout                     : SinglePage
Mod Date                        : 2002:12:10 15:24:39-06:00
Creation Date                   : 2001:07:25 09:50:12-05:00
Metadata Date                   : 2002:12:10 15:24:39-06:00
EXIF Metadata provided by EXIF.tools

Navigation menu