Hp Procurve 2610 Users Manual Install Guide
2610 to the manual 87d302db-58af-477e-ae15-9be0057af9e1
2015-02-09
: Hp Hp-Procurve-2610-Users-Manual-548398 hp-procurve-2610-users-manual-548398 hp pdf
Open the PDF directly: View PDF .
Page Count: 112
Download | |
Open PDF In Browser | View PDF |
ProCurve 2610 Switches Installation and Getting Started Guide Power over Ethernet HP ProCurve 2610 Switches Installation and Getting Started Guide Disclaimer © Copyright 2007 - 2009 Hewlett-Packard Development Company, L.P. HEWLETT-PACKARD COMPANY MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Publication Number 5991-8573 July 2009 The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Applicable Products HP ProCurve Switch 2610-24 HP ProCurve Switch 2610-24/12PWR HP ProCurve Switch 2610-24-PWR HP ProCurve Switch 2610-48 HP ProCurve Switch 2610-48-PWR HP ProCurve 600 Redundant and External Power Supply HP ProCurve 610 External Power Supply (J9085A) (J9086A) (J9087A) (J9088A) (J9089A) (J8168A) (J8169A) Hewlett-Packard assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Hewlett-Packard. Warranty See the Customer Support/Warranty booklet included with the product. A copy of the specific warranty terms applicable to your Hewlett-Packard products and replacement parts can be obtained from your HP Sales and Service Office or authorized dealer. Safety Before installing and operating these products, please read the “Installation Precautions” in chapter 2, “Installing the 2610 Switches”, and the safety statements in appendix C, “Safety and EMC Regulatory Statements”. Hewlett-Packard Company 8000 Foothills Boulevard, m/s 5552 Roseville, California 95747-5552 www.procurve.com Contents 1 Introducing the Switch Front of the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Network Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Port LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 LED Mode Select Button and Indicator LEDs . . . . . . . . . . . . . . . . 1-9 Reset Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 Clear Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11 Back of the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11 RPS and EPS Input Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12 Power Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12 Switch Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12 2 Installing the Switch Included Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Installation Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Installation Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 1. Prepare the Installation Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 2. Verify the Switch Passes Self Test . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 LED Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8 3. Mount the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 Rack or Cabinet Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 Rack Mounting the 2610-PWR switches . . . . . . . . . . . . . . . . . . . . 2-10 Rack Mounting the Non-PWR Switches . . . . . . . . . . . . . . . . . . . . 2-12 Flat Wall Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14 Wall mounting Horizontal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14 Horizontal Surface Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15 4. Connect the Switch to a Power Source . . . . . . . . . . . . . . . . . . . . . . 2-16 5. Connect the Network Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16 Using the RJ-45 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16 iii 6. Installing or Removing mini-GBICs . . . . . . . . . . . . . . . . . . . . . . . . . Installing the mini-GBICs: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Removing the mini-GBICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connecting Cables to mini-GBICs . . . . . . . . . . . . . . . . . . . . . . . . . 7. (Optional) Connect a Redundant Power Supply to a Switch 2610-PWR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The 600 RPS/EPS provides two types of power to the switches: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The 610 EPS only provides external PoE power: . . . . . . . . . . . . RPS/EPS Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating Characteristics of the 600 RPS/EPS (J8168A) . . . . . . Operating Characteristics of the 610 EPS (J8169A) . . . . . . . . . . 600 RPS/EPS LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 610 EPS LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17 2-17 2-18 2-18 2-19 2-19 2-19 2-20 2-20 2-21 2-21 2-24 8. (Optional) Connect a Console to the Switch . . . . . . . . . . . . . . . . . . 2-26 Terminal Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-26 Direct Console Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-27 Sample Network Topologies for Non-PWR Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-28 As a Desktop Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-28 As a Segment Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-29 Connecting to a Backbone Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-30 Sample Network Topologies for PWR Switches . . . . . . . . . . . . . . . . . . . . 2-32 As a Desktop Switch Implementing PoE . . . . . . . . . . . . . . . . . . . . . . . 2-32 As a Segment Switch Implementing PoE . . . . . . . . . . . . . . . . . . . . . . . 2-33 Stacking the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-35 3 Configuring the Switch Recommended Minimal Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Using the Console Setup Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 Where to Go From Here . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Using the IP Address for Remote Switch Management . . . . . . . . . . . . . . . . 3-5 Starting a Telnet Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 Starting a Web Browser Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 iv 4 Troubleshooting Basic Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 Diagnosing with the LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 LED patterns for General Switch Troubleshooting . . . . . . . . . . . . . . . 4-4 LED Patterns for PoE Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 Proactive Networking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9 Hardware Diagnostic Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10 Testing the Switch by Resetting It . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10 Checking the Switch LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10 Checking Console Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10 Testing Twisted-Pair Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11 Testing Switch-to-Device Network Communications . . . . . . . . . . . . 4-11 Testing End-to-End Network Communications . . . . . . . . . . . . . . . . . 4-11 Restoring the Factory Default Configuration . . . . . . . . . . . . . . . . . . . . . . . 4-12 Downloading New Switch Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13 HP Customer Support Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13 Before Calling Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13 A Switch Specifications Physical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 RPS/EPS Electrical Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2 Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2 BTU Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2 Acoustics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3 RPS/EPS Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3 Cable Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4 v B Cabling and Technology Information Cabling specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 Technology distance specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . B-2 Mode Conditioning Patch Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3 Installing the Patch Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3 Twisted-Pair Cable/Connector Pin-Outs . . . . . . . . . . . . . . . . . . . . . . . . . . . B-4 Straight-through Twisted-Pair Cable for 10 Mbps or 100 Mbps Network Connections . . . . . . . . . . . . . . . . . . . . B-6 Cable Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-6 Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-6 Crossover Twisted-Pair Cable for 10 Mbps or 100 Mbps Network Connection . . . . . . . . . . . . . . . . . . . . . B-7 Cable Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-7 Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-7 Straight-Through Twisted-Pair Cable for 1000 Mbps Network Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-8 Cable Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-8 Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-8 C Safety and EMC Regulatory Statements Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1 Informations concernant la sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2 Hinweise zur Sicherheit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3 Considerazioni sulla sicurezza . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-4 Consideraciones sobre seguridad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-5 Safety Information (Japan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-6 Safety Information (China) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-7 EMC Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8 U.S.A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8 Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8 Australia/New Zealand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8 Japan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8 Korea . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-9 Taiwan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-9 European Community . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-10 vi D Recycle Statements Waste Electrical and Electronic Equipment (WEEE) Statements . . . . . . D-1 Index vii 1 Introducing the Switch HP ProCurve Switch 2610-24 (J9085A) HP ProCurve Switch 2610-48 (J9088A) HP ProCurve Switch 2610-24/12PWR (J9086A) HP ProCurve Switch 2610-24-PWR (J9087A) HP ProCurve Switch 2610-48-PWR (J9089A) 1-1 Introducing the Switch The ProCurve 2610 Switches are multiport switches that can be used to build high-performance switched workgroup networks. These switches are storeand-forward devices that offer low latency for high-speed networking. The 2610-PWR Switches also support Redundant Power Supply and Power over Ethernet (PoE) technologies. Introducing the Switch Introducing the Switch Throughout this manual, these switches will be referred to as the 2610 Switches and the 2610-PWR Switches. ■ The 2610 Switches, has either 24 or 48 auto-sensing 10/100Base-TX RJ-45 ports with four Gigabit Uplink ports, two RJ-45 and two mini-GBIC (Small Form Factor Pluggable (SFP)) slots. For a list of supported mini-GBICs see page 2-17. The RJ-45 Gigabit Uplink ports are auto-sensing 10/100/1000Base-T. These ports operate independently, they are not dual-personality. Table 1-1. These products support optional network connectivity with the following speeds and technologies: Transceiver FormFactor and Connector Speed Technology Cabling 1 SFP (“mini-GBIC”) Connector 100-FX Fiber (multimode) LC 100-BX Fiber (single mode) LC 1000-T Copper (twisted-pair) RJ-45 1000-SX Fiber (multimode) LC 1000-LX Fiber (multimode or single mode) LC 1000-LH Fiber (single mode) LC 1000-BX Fiber (single mode) LC 100 Mbps 1 Gbps 1 For supported transceivers, see www.hp.com/go/procurve/faqs. ProCurve Mini- GBICs and SFPs have links to a list of supported products (first question in the “General product information” category). For technical details of cabling and technologies see “Cabling and Technology Information” in the appendices. The 2610-PWR Switches incorporate two additional features. These switches offer two types of power, one for switch AC operating power, and the other for Power over Ethernet (PoE) power: ■ 1-2 Power-over-Ethernet or PoE power - PoE technology allows IP telephones, wireless LAN Access Points and other appliances to receive power as well as data over existing LAN cabling, without needing to modify the existing Ethernet infrastructure. The 2610-PWR Switches are designed with an internal PoE power supply capable of providing 406 watts of PoE power (126 watts on the 2610-24/12PWR). All of the Switch 2610-PWR ports can provide up to 15.4 watts (or 7.5 watts if all 12 ports are used on the 2610-24/12PWR) of PoE power to connected devices. Introducing the Switch For further information regarding PoE power, see the PoE Planning and Implementation Guide, which is on the ProCurve Web site at www.hp.com/go/procurve/manuals, (See page 1-13). ■ Redundant and External Power Supply Support - The 2610-PWR Switches can be connected to a ProCurve 600 Redundant and External Power Supply (J8168A), hereafter referred to as the 600 RPS/EPS or a ProCurve 610 External Power Supply, hereafter referred to as the 610 EPS, and receive redundant power from that unit. As an RPS unit, the 600 RPS/ EPS will provide all the AC power necessary to keep the switch running should the switch internal AC power supply fail. As an EPS unit, the 600 RPS/EPS and the 610 EPS can supply up to 408 watts of PoE power to the switch if the internal PoE power supply of the switch should fail. When used with the Switch 2610-48-PWR, the additional EPS power can provide up to 15.4 watts per port for 48 ports. For further information regarding the 600 RPS/EPS or the 610 EPS PoE capabilities, see the PoE Planning and Implementation Guide, which is on the ProCurve Web site at www.hp.com/go/procurve/manuals, (See page 1-13). These switches can be directly connected to computers, printers, and servers to provide dedicated bandwidth to those devices, and you can build a switched network infrastructure by connecting the switch to hubs, other switches, or routers. In addition, the 2610 Switches offer full network management capabilities. 1-3 Introducing the Switch ■ Introducing the Switch Introducing the Switch Front of the Switch Front of the Switch Power and Fault LEDs Console Port Power and Fault LEDs Console Port Power and Fault LEDs RPS, Fan and Test Status LEDs 1-4 LED Mode select button and indicator LEDs Reset and Clear buttons RPS, EPS, Fan and Test Status LEDs 10/100Base-TX RJ-45 ports1 Switch port LEDs LED Mode select button and indicator LEDs Reset and Clear buttons Uplink ports (1000Base-T2 and mini-GBIC) ProCurve Switch 2610-48-PWR 10/100Base-TX RJ-45 ports1 Uplink ports (1000Base-T2 and Mini-GBIC) ProCurve Switch 2610-24 RPS and Test Status LEDs Reset and Clear buttons Console Port ProCurve Switch 2610-48 Switch port LEDs Switch port LEDs LED Mode select button and indicator LEDs 10/100Base-TX RJ-45 ports1 1 All 10/100Base-TX RJ-45 ports have the Auto-MDIX feature. 2 Two RJ-45 10/100/1000Base-T ports and two Mini-GBIC (SFP) slots. Uplink ports (1000Base-T2 and Mini-GBIC) Introducing the Switch Front of the Switch Network Ports 24, or 48 auto-sensing 10/100Base-TX ports. All these ports have the “Auto-MDIX” feature, which means that you can use either straight-through or crossover twisted-pair cables to connect any network devices to the switch. ■ Two RJ-45 10/100/1000Base-T ports for high speed uplink. ■ Two mini-GBIC (SPF) slots for fiber uplinks. LEDs On the 2610 Switches, there are three groupings of LEDs: ■ switch status LEDs (Table 1-2) ■ port LEDs (Table 1-3) ■ Port LED Mode indicator LEDs (near the selector button) (Table 1-4) Table 1-2. Switch Status LEDs Switch LEDs State Meaning Power (green) On The internal power supply is working properly. Off No power connection. The switch is NOT receiving power. Flashing2 A failure of the internal power supply. It should be flashing simultaneously with the Fault LED. (If an RPS is connected to the switch, the RPS is actively powering the switch, the RPS LED will be on.) Off The normal state; indicates there are no fault conditions on the switch. Fault (orange) Locator (blue) 2 Flashing A fault has occurred with a component on the switch. The Status LED for the component with the fault will flash simultaneously. On On briefly after the switch is powered on or reset, at the beginning of switch self test. If this LED is on for a prolonged time, the switch has encountered a fatal hardware failure, or has failed its self test. See chapter 4, “Troubleshooting” for more information. On Flashing Off The Locator LED is used to locate a specific switch in an area full of switches. The LED can be set to be on solid or flash for a specified number of minutes (1-1440). The default is 30 minutes. Use the command “chassislocate”. 1-5 Introducing the Switch ■ Introducing the Switch Introducing the Switch Front of the Switch Switch LEDs State Meaning PoE (green/ orange)3 On Normal operation. The switch is ready to supply PoE power Flashing/ orange2 One or more ports has experienced a fault condition for PoE delivery. The Fault LED will be flashing simultaneously. If it is a self test failure, the Test LED will be flashing simultaneously. When the switch is put in PoE LED Mode, The Mode LED for the port with the problem will also be flashing simultaneously. Flashing/ orange1 One or more ports has an alert condition for PoE delivery, for example, an oversubscription condition (not enough PoE power available). Only this LED will be flashing, the Fault LED is off. When the switch is put in PoE LED Mode, The Mode LEDs for the ports with the alert condition will also be flashing. On Normal operation. An external power supply is connected and operating correctly. The external power supply could be powering the unit. Flashing orange1 An external power supply is connected but may be powering another switch or the external power supply has experienced a fault. Only this LED flashes, the Fault LED is off. Off An external power supply is not connected. On The switch is connected to an external power supply and operating correctly. Flashing orange1 The external power supply has experienced a fault: • There is a fan, overcurrent, power supply, or temp fault on the EPS. • The Switch detects the EPS is present but cannot communicate with it. Check the Error Log on the switch for more information. RPS Status (green/ orange) EPS Status 3 (green) Fan (green/ orange) 1-6 Off The switch is not connected to an external power supply or the EPS cable is connected but the external power supply is not powered up. On The cooling fan is operating normally. Flashing orange2 The cooling fan has failed. The switch Fault LED will be flashing simultaneously. Introducing the Switch Front of the Switch State Meaning Test (green/ orange) Off The normal operational state; the switch is not undergoing self test. On The switch self test and initialization are in progress after the switch has been power cycled or reset. The switch is not operational until this LED goes off. The Test LED also comes on briefly when you “hot swap” a miniGBIC into the switch; the mini-GBIC is tested when it is hot swapped. Flashing orange2 A component of the switch has failed its self test. The switch Fault LED, Test LED, and the failed component LED will flash simultaneously. 1 The flashing behavior is an on/off cycle once every 0.8 seconds approximately, a fast flash. 2 The flashing behavior is an on/off cycle once every 1.6 seconds approximately, a slow flash. 3 ProCurve Switch 2610-PWR Series only. See the ProCurve 600/610 External Power Supplies Installation and Getting Started Guide for information on the LED behavior of the external power supplies. 1-7 Introducing the Switch Switch LEDs Introducing the Switch Front of the Switch Introducing the Switch Port LEDs The port LEDs provide information about the individual switch ports. Table 1-3. Switch LEDs Port LEDs State Meaning Switch 2610 non-PWR Series Port LEDs Mini-GBIC LEDs: Link Link and Mode (green) Displays port link information, network activity information, whether the port is configured for full-duplex operation, or the speed of the connection depending on the LED Mode selected. See “LED Mode Select Button and Indicator LEDs” on the next page for more information. Flashing orange One of the following conditions exist: • the mini-GBIC is not supported by the current software • the mini-GBIC is not a genuine ProCurve Mini-GBIC and is not supported • the mini-GBIC is an “A” version in a switch that requires a “B” version or later. On for 2 seconds Both the Link and Mode LED turn on solid for 2 seconds and then go to normal operation. This indicates the mini-GBIC has been recognized by the switch. Switch 2610-PWR Series Link (green) Mode (green) On The port is enabled and receiving a link indication from the connected device. In PoE mode, indicates that the port is configured to enable PoE power delivery to the connected device. Off One of these condition exists: • no active network cable is connected to the port • the port is not receiving link beat or sufficient light • the port has been disabled through the switch console, the web browser interface, ProCurve Manager, or other network management tool. • In PoE mode, indicates that the port is configured such that PoE power delivery is disabled. Flashing1 The port has failed self test. The switch Fault, and Self Test LEDs will flash simultaneously. Depending on the mode selected, displays the following: • Connection speed information • network activity information • PoE power delivery status See “LED Mode Select Button and Indicator LEDs:” below for more information. 1 The flashing behavior is an on/off cycle once every 1.6 seconds, approximately. 1-8 Introducing the Switch Front of the Switch LED Mode Select Button and Indicator LEDs The non-PWR switches, have two LEDs per port. The Link status is always shown by the Link LED. The operation of the Mode LED is controlled by the LED Mode select button, and the current setting is indicated by the LED Mode indicator LEDs near the button. Press the button to step from one view mode to the next. The default view is Activity (Act). Link LED Mode LED LED Mode select button and indicator LEDs Figure 1-1. 2610 non-PWR Switches The PWR switches also have two LEDs per port. The Link status is always shown by the Link LED as with the non-PWR switches. The operation of the Mode LED is the same as the non-PWR switches. The difference is the PWR switches have an additional mode, and that is PoE. In PoE mode, the Link LED indicates the PoE configuration for the port: On if PoE is enabled on the port; Off if PoE is disabled on the port. The default view is Activity (Act). Link LED (port number) Mode LED LED Mode select button and indicator LEDs Figure 1-2. 2610-PWR Switches 1-9 Introducing the Switch To optimize the amount of information that can be displayed for each of the switch ports in the limited space available, the 2610 Switches use multipledisplay LEDs for each port. Introducing the Switch Front of the Switch Introducing the Switch Table 1-4. Switch LEDs State Multiple-Display Port LEDs Meaning All 2610 Switches Port LED View indicator LEDs 3 green LEDs) Act FDx Spd Indicates the Port LEDs are displaying network activity information. Indicates the Port LEDs are lit for ports that are in full-duplex mode. Indicates the Port LEDs are displaying the connection speed at which each port is operating: • if the Port LED is off, the port is operating at 10 Mbps. • if the Port LED is flashing, the port is operating at 100 Mbps. • if the Port LED is on continuously, the port is operating at 1000 Mbps. Switch 2610-PWR Series LED Mode indicator LEDs (PoE is the additional LED, green) PoE Indicates the Port LEDs are lit for ports that are providing PoE power to the connected device. Reset Button This button is for: ■ Resetting the switch - When the switch is powered on. This action clears any temporary error conditions that may have occurred and executes the switch self test. ■ Restoring Factory Default Configuration - When pressed with the Clear button in a specific pattern, any configuration changes you may have made through the switch console, the web browser interface, and SNMP management are removed, and the factory default configuration is restored to the switch. For the specific method to restore the factory default configuration, see “Restoring the Factory Default Configuration” on page 12, “Troubleshooting” of this manual. Clear Button This button is used for: 1-10 ■ Deleting Passwords - When pressed by itself for at least one second, the button deletes any switch console access passwords that you may have configured. Use this feature if you have misplaced the password and need console access. This button is provided as a convenience, however if you are concerned with the security of the switch configuration and operation, you should make sure the switch is installed in a secure location. This button can be disabled by a CLI command. ■ Restoring Factory Default Configuration - See Reset Button above. Introducing the Switch Back of the Switch Console Port Back of the Switch RPS Input AC power connector Figure 1-3. ProCurve Switch 2610-24 and 2610-48 non-PWR EPS Input AC power connector RPS Input Figure 1-4. ProCurve Switch 2610-24-PWR and 2610-48-PWR EPS Input RPS Input AC power connector Figure 1-5. ProCurve Switch 2610-24/12PWR 1-11 Introducing the Switch This port is used to connect a console to a 2610 Switches by using the RJ-45 to DB9 cable, supplied with the switch. This connection is described under “8. (Optional) Connect a Console to the Switch” on page 26 in chapter 2, “Installing the Switch.” The console can be a PC or workstation running a VT-100 terminal emulator, or a VT-100 terminal. Introducing the Switch Switch Features Introducing the Switch RPS and EPS Input Port The 2610 Switches support connectivity to a redundant power supply (RPS/ EPS). The ProCurve 600 Redundant and External Power Supply (J8168A) and the ProCurve 610 External Power Supply (J8169A) are accessory products for these switches. The RPS functionality of the 600 procides redundant system power in case the switch’s internal power supply fails. The EPS functionality of the 600 and the 610 provides additional PoE power. Power Connector The 2610 Switches and 2610-PWR Switches do not have a power switch; they are powered on when connected to an active AC power source. The switches automatically adjust to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz. There are no voltage range settings required. Switch Features The features of the 2610 Switches and 2610-PWR Switches include: 1-12 ■ 24, or 48 auto-sensing 10/100Base-TX RJ-45 ports with Auto-MDIX. ■ 4 Uplink ports—two are 1000Base-T RJ-45 and two are mini-GBIC (SFP) slots. ■ Power over Ethernet (PoE) operation—the 2610-PWR Switches are IEEE 802.3af compliant and provide up to 15.4W per port to power IP phones, wireless access points, web cameras, and more. For more information, see the PoE Planning and Implementation Guide, which is on the ProCurve Web site at www.hp.com/go/procurve/manuals, (See page 1-13). ■ The 2610-PWR Switches support some pre-standard PoE devices. However, the use of a cross-over cable may be required. For a current list see the FAQ page for the 2610-PWR Switch, which can be found on the ProCurve Web site, www.hp.com/go/procurve/manuals, Technical Support, FAQs (all). ■ Plug-and-play networking—all ports are enabled—just connect the network cables to active network devices and your switched network is operational. ■ Auto-MDIX on all twisted-pair ports, 10/100 and 10/100/1000, meaning that all twisted-pair connections can be made using straight-through cables. Cross-over cables are not required, although they will also work. ■ Automatic learning of the hardware addresses in each switch’s 8000address forwarding table, (with configurable address aging value). Introducing the Switch Switch Features Automatically negotiated full-duplex operation for the 10/100 and 10/100/1000 RJ-45 ports when connected to other auto-negotiating devices—the mini-GBIC ports always operate at full duplex, unless a 100-FX SFP transceiver is installed. The 100-FX SFP transceiver can operate at half duplex. ■ Easy management of the switches through several available interfaces: • console interface—a full featured, easy to use, VT-100 terminal interface that is especially good for out-of-band switch management or for Telnet access to the switch. • web browser interface—an easy to use built-in graphical interface that can be accessed from common web browsers. • ProCurve Manager—an SNMP-based, graphical network management tool that you can use to manage your entire network. ■ Support for the Spanning Tree Protocol to eliminate network loops ■ Support for up to 30 IEEE 802.1Q-compliant VLANs so you can divide the attached end nodes into logical groupings that fit your business needs. ■ Download of new switch software for product enhancements or bug fixes. ■ Dual-speed fans to maintain cooling if the environment warms up on the following switches: ■ • Switch 2610-48 (J9088A) • Switch 2610-24/12PWR (J9086A) • Switch 2610-24-PWR (J9087A) • Switch 2610-48-PWR (J9089A) Support for many advanced features to enhance network performance— for a description, see the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/go/procurve/manuals. To display the list of downloadable manuals, click on the following link: HP ProCurve Switch 2610 Series. (You may want to bookmark this Web page for easy access in the future.) 1-13 Introducing the Switch ■ 2 Installing the Switch The ProCurve 2610 Switches come with an accessory kit that includes the brackets for mounting the switch in a standard 19-inch telco rack, in an equipment cabinet, or on a wall. The brackets are designed to allow mounting the switch in a variety of locations and orientations. Rubber feet are provided that can be attached so the switch can be securely located on a horizontal surface. Installing the Switch This chapter shows how to install the Switch 2610. Included Parts The 2610 Switches have the following components: ■ HP ProCurve Switch Quick Setup Sheet ■ Read Me First ■ HP ProCurve Switches General Safety and Regulatory Information booklet ■ 2610 Switch Specific Safety and Regulatory Information sheet ■ ■ Console cable Customer Support/Warranty booklet ■ Accessory kits: 2610 Non-PWR switches and the J9086A 24/12-port partial PoE switch 2610-PWR switches, J9087A and J9089A Kit number 5069-6535 Contains: • two mounting brackets • eight 8-mm M4 screws to attach the mounting brackets to the switch • four 5/8-inch number 12-24 screws to attach the switch to a rack • four rubber feet Kit number 5069-5705 Contains: • two mounting brackets 1 • eight 8-mm M4 screws to attach the mounting brackets to the switch • four 5/8-inch number 12-24 screws to attach the switch to a rack • four rubber feet 1 The mounting brackets in this kit are longer to support the increased depth of the 2610- PWR products. 2-1 Installing the Switch Included Parts Installing the Switch ■ AC power cord, one of the following: Australia/New Zealand China Continental Europe Denmark Japan Switzerland United Kingdom/Hong Kong/Singapore United States/Canada/Mexico South Africa Thailand Taiwan India Non-PWR Switches PWR Switches 1 8120-6803 8120-8377 8120-6802 8120-6806 8120-6804 8120-6807 8120-8709 8120-6805 8120-8929 8121-0673 8121-0964 8121-0780 8120-6810 8120-8471 8120-6811 8120-6814 8120-6804 8120-6815 8120-6809 8120-2371 8120-8929 8121-0673 8121-0964 8120-8929 2 1 The cords for the PWR Switches support a higher amperage. 2 Japan Power Cord Warning 2-2 The 2610-24/12PWR Switch in India uses the 8121-0780 power cord. Installing the Switch Included Parts Installation Precautions WARNING ■ The rack or cabinet should be adequately secured to prevent it from becoming unstable and/or falling over. Devices installed in a rack or cabinet should be mounted as low as possible, with the heaviest devices at the bottom and progressively lighter devices installed above. For safe operation do not install the switch with the side of the switch (with the fan vents) facing either downward or upward. ■ Do not wall mount the 2610-PWR switches. ■ If one of the following switches is to be mounted in a rack, you can use a rail kit. Rail kit part number 508783-B21 can be used only with the following switches. • J9085A ProCurve Switch 2610-24 • J9088A ProCurve Switch 2610-48 • J9086A ProCurve Switch 2610-24/12PWR ■ Ensure the power source circuits are properly grounded, then use the power cord supplied with the switch to connect it to the power source. ■ If your installation requires a different power cord than the one supplied with the switch, ensure the cord is adequately sized for the switch’s current requirements. In addition, be sure to use a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country. The mark is your assurance that the power cord can be used safely with the switch. If the PWR device’s supplied power cord does not fit, contact ProCurve Networking support. ■ When installing the switch, the AC outlet should be near the switch and should be easily accessible in case the switch must be powered off. ■ Ensure the switch does not overload the power circuits, wiring, and overcurrent protection. To determine the possibility of overloading the supply circuits, add together the ampere ratings of all devices installed on the same circuit as the switch and compare the total with the rating limit for the circuit. Maximum ampere ratings are usually printed on the devices near the AC power connectors. ■ Do not install the switch in an environment where the operating ambient temperature might exceed 50°C (122°F). This includes a fully-enclosed rack. Ensure the air flow around the sides and back of the switch is not restricted. Leave at least 7.6 cm (3 inches) for cooling. ■ Ensure all port covers are installed when the port is not in use. 2-3 Installing the Switch Cautions ■ Installing the Switch Installation Procedures Installation Procedures Installing the Switch These steps summarize your switch installation. The rest of this chapter provides details on these steps. 1. Prepare the installation site (page 2-6). Make sure the physical environment into which you will be installing the switch is properly prepared, including having the correct network cabling ready to connect to the switch and having an appropriate location for the switch. See page 2-3 for some installation precautions. 2. Verify the switch passes self test (page 2-6). Plug the switch into a power source and observe that the LEDs on the switch’s front panel indicate correct switch operation. 3. Mount the switch (page 2-9). The 2610 Switches can be mounted in a 19-inch telco rack, in an equipment cabinet, on a wall, or on a horizontal surface. The 2610-PWR Switches may be mounted in racks and cabinets or on a horizontal surface. The 2610-PWR Switches must not be wall mounted. The 2610 Non-PWR Switches can be wall mounted. See page 2-14 for wall mounting instructions. The following switches can be rack mounted with rail kit part number 508783-B21. 2-4 • J9085A ProCurve Switch 2610-24 • J9088A ProCurve Switch 2610-48 • J9086A ProCurve Switch 2610-24/12PWR 4. Connect power to the switch (page 2-16). Once the switch is mounted, plug it into the main power source. 5. Connect the network devices (page 2-16). Using the appropriate network cables, connect the network devices to the switch ports. 6. (Optional) Install mini-GBICs (page 2-17). The switch has two slots for installing mini-GBICs. Depending on where you install the switch, it may be easier to install the mini-GBICs first. Mini-GBICs can be hot swapped—they can be installed or removed while the switch is powered on. 7. (Optional) Connect a 600 RPS/EPS or 610 EPS (page 2-18). You may wish to use a 600 RPS/EPS or 610 EPS with your Series 2610-PWR Switch. To do so you must connect these external power supplies using the RPS or EPS cables supplied with these devices. Installing the Switch Installation Procedures 8. (Optional) Connect a console to the switch (page 2-26). You may wish to modify the switch’s configuration, for example, to configure an IP address so it can be managed using a web browser, from an SNMP network management station, or through a Telnet session. Configuration changes can be made by using the included console cable to connect a PC to the switch’s console port. At this point, your switch is fully installed. See the rest of this chapter if you need more detailed information on any of these installation steps. Installing the Switch 2-5 Installing the Switch Installation Procedures 1. Prepare the Installation Site Cabling Infrastructure - Ensure the cabling infrastructure meets the necessary network specifications. See the following table for cable types and lengths, and see appendix B, “Cabling and Technology Information” for more information: Installing the Switch ■ Installation Location - Before installing the switch, plan its location and orientation relative to other devices and equipment: • In the front of the switch, leave at least 7.6 cm (3 inches) of space for the twisted-pair and fiber-optic cabling. • In the back of the switch, leave at least 3.8 cm (1 1/2 inches) of space for the power cord. • On the sides of the switch, leave at least 7.6 cm (3 inches) for cooling. 2. Verify the Switch Passes Self Test Before mounting the switch in its network location, you should first verify it is working properly by plugging it into a power source and verifying it passes its self test. 1. Connect the power cord supplied with the switch to the power connector on the back of the switch, and then into a properly grounded electrical outlet. Connect power cord to the power connector Figure 2-1. Connecting the power cord 2-6 Installing the Switch Installation Procedures Note The 2610 Switches do not have a power switch. They are powered on when the power cord is connected to the switch and to a power source. For safety, the power outlet should be located near the switch installation. The switch automatically adjusts to any voltage between 100-127 or 200-240 volts and either 50 or 60 Hz. There are no voltage range settings required. 2. Check the LEDs on the switch as described below. Self Test LED Switch port LEDs Power and Fault LEDs Figure 2-2. Checking the LEDs on the 2610 non-PWR switches 2-7 Installing the Switch If your installation requires a different power cord than the one supplied with the switch, be sure the cord is adequately sized for the switch’s current requirements. In addition, be sure to use a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country. The mark is your assurance that the power cord can be used safely with the switch. If the PWR device’s supplied power cord does not fit, contact ProCurve Networking support. Installing the Switch Installation Procedures When the switch is powered on, it performs its diagnostic self test. Self test takes approximately 50 seconds to complete. Self Test LED Switch port LEDs Installing the Switch Power and Fault LEDs Figure 2-3. Checking the LEDs on the 2610-PWR switches LED Behavior During the self test: • Initially, all the switch and port LEDs are on. Most of the LEDs go off and then may come on again during phases of the self test. • For the duration of the self test, the Self Test LED stays on. When the self test completes successfully: • The Power and Fan LEDs remain on. • The Fault and Test LEDs go off. • The port LEDs on the front of the switch go into their normal operational mode: – If the ports are connected to active network devices, the LEDs behave according to the Port LED View or LED Mode selected. The default view mode (Link), the LEDs should be on and the Mode LEDs will flicker if there is network activity. – If the ports are not connected to active network devices, the Link and Act LEDs will stay off. If the LED display is different than what is described above, especially if the Fault and Test LEDs stay on for more than 60 seconds or they start flashing, the self test has not completed correctly. Refer to chapter 4, “Troubleshooting” for diagnostic help. 2-8 Installing the Switch Installation Procedures 3. Mount the Switch After the switch passes self test, it is ready to be mounted in a stable location. The 2610 Switches can be mounted in these ways: Mounting Location Non-PWR Switches PWR Switches In a rack or cabinet Yes Yes On a horizontal surface Yes Yes On a wall Yes No The 2610 Switches are designed to be mounted in any EIA-standard 19-inch telco rack or communication equipment cabinet. Note that the mounting brackets have multiple mounting holes and can be rotated allowing for a wide variety of mounting options. Secure the rack in accordance with the manufacture’s safety guidelines. WARNING For safe operation, please read the mounting precautions on page 2-3, before mounting a switch. Equipment Cabinet Note The 12-24 screws supplied with the switch are the correct threading for standard EIA/TIA open 19-inch racks. If installing the switch in an equipment cabinet such as a server cabinet, use the clips and screws that came with the cabinet in place of the 12-24 screws that are supplied with the switch. 2-9 Installing the Switch Rack or Cabinet Mounting Installing the Switch Installation Procedures Rack Mounting the 2610-PWR switches Installing the Switch 1. Use a #1 Phillips (cross-head) screwdriver and attach the mounting brackets to the switch with the included 8-mm M4 screws. Figure 2-4. Attaching large mounting brackets WARNING For safe reliable installation, only use the screws provided in the accessory kit to attach the mounting brackets to the switch. Note The mounting brackets have multiple mounting holes and can be rotated allowing for a wide variety of mounting options. These include mounting the switch so that its front face is flush with the face of the rack, or mounting it in a more balanced position as shown in the illustration above. 2-10 Installing the Switch Installation Procedures 2. Hold the switch with attached brackets up to the rack and move it vertically until rack holes line up with the bracket holes, then insert and tighten the four number 12-24 screws holding the brackets to the rack. Installing the Switch Install 12-24 screws Figure 2-5. Mounting in a rack 2-11 Installing the Switch Installation Procedures Rack Mounting the Non-PWR Switches Installing the Switch 1. Use a #1 Phillips (cross-head) screwdriver and attach the mounting brackets to the switch with the included 8-mm M4 screws. 8 mm M4 screws Figure 2-6. Attaching small mounting brackets Note The mounting brackets have multiple mounting holes and can be rotated allowing for a wide variety of mounting options. These include mounting the switch so that its front face is flush with the face of the rack, or mounting it in a more balanced position as shown in the illustration. WARNING For safe reliable installation, only use the screws provided in the accessory kit to attach the mounting brackets to the switch. 2-12 Installing the Switch Installation Procedures 2. Hold the switch with attached brackets up to the rack and move it vertically until rack holes line up with the bracket holes, then insert and tighten the four number 12-24 screws holding the brackets to the rack. Installing the Switch Install 12-24 screws Figure 2-7. Mounting in a rack 2-13 Installing the Switch Installation Procedures Flat Wall Mounting There are two switches in this series that can be wall mounted, the J9085A 24port Non-PoE and the J9088A 48-port Non-PoE. You can mount these switches on a wall as shown in the illustration Figure 2-8. Wall mounting is not supported for the 2610-PWR switches because of the size and weight of the devices. See page 2-14 for instructions. For safe operation do not install the switch with either side vent holes (vertical) facing downward. Do not wall mount the 2610-PWR switches. Caution The switch should be mounted only to a wall or wood surface that is at least 1/2-inch (12.7 mm) plywood or its equivalent. Installing the Switch WARNING Supported Wall Mounting Positions. Switch WARNING Vertical Wall Mounting Horizontal Wall Mounting 2610 Non-PWR No Yes 2610-PWR No No The Switch 2610-PWR Switches are not wall mountable. Wall mounting Horizontal 2-14 1. Use a #1 Phillips (cross-head) screwdriver and attach the mounting brackets to the switch with the included 8-mm M4 screws. 2. Attach the switch to the wall or wood surface with two 5/8-inch number 12 wood screws (not included). Installing the Switch Installation Procedures RJ-45 Ports Wall Installing the Switch M4 screws 5/8-inch wood screws Figure 2-8. Horizontal wall mounting Caution The J9088A 48-port, non-PWR switch can be wall mounted with either the RJ-45 ports side up or down in the horizontal orientation. A vertical wall mount orientation is not supported. The J9085A 24-port, non-PWR switch can be wall mounted with the RJ-45 port side facing down only in the horizontal orientation. A vertical wall mount orientation is not supported. Horizontal Surface Mounting Place the switch on a table or other horizontal surface. The switch comes with rubber feet in the accessory kit that can be used to help keep the switch from sliding on the surface. Attach the rubber feet to the four corners on the bottom of the switch within the embossed angled lines. Use a sturdy surface in an uncluttered area. You may want to secure the networking cables and switch power cord to the table leg or other part of the surface structure to help prevent tripping over the cords. Caution Ensure the air flow is not restricted around the sides and back of the switch. 2-15 Installing the Switch Installation Procedures Installing the Switch 4. Connect the Switch to a Power Source 1. Plug the included power cord into the switch’s power connector and into a nearby AC power source. 2. Re-check the LEDs during self test. See “LED Behavior” on page 2-8. Figure 2-9. Connecting the power cord 5. Connect the Network Cables Connect the network cables, described under “Cabling Infrastructure” (page 2-6), from the network devices or your patch panels to the fixed RJ-45 ports on the switch or to any mini-GBICs you have installed in the switch. Using the RJ-45 Connectors To connect: Push the RJ-45 plug into the RJ-45 port until the tab on the plug clicks into place. When power is on for the switch and for the connected device, the Link LED for the port should light to confirm a powered-on device (for example, an end node) is at the other end of the cable. If the Link LED does not go on when the network cable is connected to the port, see “Diagnosing With the LEDs” in chapter 4, “Troubleshooting”. To disconnect: Press the small tab on the plug and pull the plug out of the port. 2-16 RJ-45 connector Unshielded twisted-pair cable: • Category 3, 4, or 5 for 10 Mbps ports • Category 5 or better for 100 Mbps ports • Category 5e or better for 1000 Mbps ports Maximum distance: 100 meters Figure 2-10. Connecting network cables Installing the Switch Installation Procedures 6. Installing or Removing mini-GBICs You can install or remove a mini-GBIC from a mini-GBIC slot without having to power off the switch. Use only ProCurve mini-GBICs. Notes The mini-GBIC slots are not shared with the two 10/100/1000Base-T RJ45 ports. When a mini-GBIC is installed in a slot, it operates independently of the RJ-45 ports. ■ The mini-GBIC ports operate only at full duplex. Half duplex operation is not supported, unless a 100-FX SFP transceiver is installed. The 100-FX SFP transceiver can operate at half duplex. ■ Ensure the network cable is NOT connected when you install or remove a mini-GBIC. Use only supported genuine ProCurve mini-GBICs with your switch. NonProCurve mini-GBICs are not supported, and their use may result in product malfunction. Should you require additional ProCurve mini-GBICs, contact your ProCurve Networking Sales and Service Office or authorized dealer. Installing the mini-GBICs: Remove the protective plastic cover and retain it for later use. Hold the miniGBIC by its sides and gently insert it into either of the slots on the switch until the mini-GBIC clicks into place. WARNING The ProCurve mini-GBICs are Class 1 laser devices. Avoid direct eye exposure to the beam coming from the transmit port. Figure 2-11. Installing a mini-GBIC (SFP) 2-17 Installing the Switch Caution ■ Installing the Switch Installation Procedures Removing the mini-GBICs Note You should disconnect the network cable from the mini-GBIC before removing it from the switch. Depending on when you purchased your ProCurve mini-GBIC, it may have either of three different release mechanisms: a plastic tab on the bottom of the mini-GBIC, a plastic collar around the mini-GBIC, or a wire bail. Installing the Switch To remove the mini-GBICs that have the plastic tab or plastic collar, push the tab or collar toward the switch until you see the mini-GBIC release from the switch (you can see it move outward slightly), and then pull it from the slot. To remove the mini-GBICs that have the wire bail, lower the bail until it is approximately horizontal, and then using the bail, pull the mini-GBIC from the slot. Replace the protective plastic cover on the mini-GBIC. Connecting Cables to mini-GBICs If you have any mini-GBICs installed in the switch, the type of network connections you will need to use depends on the type of mini-GBICs you have installed. See appendix B, “Cabling and Technology Information”, for cabling information. For mini-GBICs ports, and in general for all the switch ports, when a network cable from an active network device is connected to the port, the port LED for that port should go on. If the port LED does not go on when the network cable is connected to the port, see “Diagnosing with the LEDs” in chapter 4, “Troubleshooting”. 7. (Optional) Connect a Redundant Power Supply to a Switch 2610-PWR Series The ProCurve 600 Redundant and External Power Supply, (J8168A), hereafter referred to as the 600 RPS/EPS, and the ProCurve 610 External Power Supply (J8169A), hereafter referred to as the 610 EPS, are accessory products for the Switch 2610-PWR Series and specific other ProCurve switches. 2-18 Installing the Switch Installation Procedures The 600 RPS/EPS provides two types of power to the switches: Redundant power to one of up to six switches, to back up the internal switch power supply in case of AC power loss, or a fault condition. Should the internal switch power supply fail, power will be supplied from the 600 RPS/EPS, if it is available, that is, if the 600 RPS/EPS is not already providing power to a higher priority switch. See the documentation that came with your 600 RPS/EPS for more information. ■ External Power-over-Ethernet (PoE) power to up to two switch products. The 600 RPS/EPS can supply 408 watts of PoE power to the switch if the internal PoE power supply should fail. For the Switch 2610-24/12PWR and 2610-48-PWR the external PoE power is additional power made available to the switch’s ports. For further information regarding the 600 RPS/EPS PoE capabilities, see the PoE Planning and Implementation Guide and the ProCurve 600/610 External Power Supplies Installation and Getting Started Guide, which is on the ProCurve Web site at www.hp.com/go/ procurve/manuals, (See page 1-13). The 600 RPS/EPS is an unmanaged power supply that only provides information by way of LEDs. The 610 EPS only provides external PoE power: ■ External Power-over-Ethernet (PoE) power to up to four switch products. The 610 EPS can supply 408 watts (if one port of a pair is used) or 204 watts (if two ports of a pair are used) of PoE power to the switch if the internal PoE power supply should fail. For the Switch 2610-48-PWR the external PoE power is additional power made available to the switch’s ports. For further information regarding the 600 RPS/EPS and the 610 EPS PoE capabilities, see the PoE Planning and Implementation Guide and the ProCurve 600/610 External Power Supplies Installation and Getting Started Guide, which is on the ProCurve Web site at www.hp.com/go/ procurve/manuals, (See page 1-13). The 610 EPS is an unmanaged power supply that only provides information by way of LEDs. RPS/EPS Operation The RPS/EPS monitors the power signal from the switch by detecting that the RPS/EPS is connected to a switch with an RPS/EPS cable. When the power from the switch is no longer detected, the RPS/EPS will provide power to the switch within 1 millisecond. 2-19 Installing the Switch ■ Installing the Switch Installation Procedures The RPS/EPS supports hot plugging of the RPS/EPS cable without causing a reboot of the switch or causing the power supply in either the RPS/EPS or switch to shut down temporarily or permanently. For more information refer to the documentation that came with the RPS/EPS. Operating Characteristics of the 600 RPS/EPS (J8168A) The 600 RPS/EPS has six RPS ports, each of which can provide redundant +12V power to a connected switch, but only one connector can provide this power at a given time. Installing the Switch If a switch with no AC power is connected to an operating 600 RPS/EPS, it will receive power if power is available (no higher priority port is already using the RPS power). If two or more devices fail, priority goes to the device plugged into the lower numbered port on the 600 RPS/EPS unit. Consequently the most important switch should be plugged into port one on the 600 RPS/EPS. In this state, the “Connected” LED should be ON, and the “Power Status” LED should be flashing on the lower priority RPS port not supplying power. (Refer to the documentation that came with your 600 RPS/EPS unit.) The 600 RPS/EPS also has two EPS Ports. The 600 RPS/EPS can provide a maximum of 408 watts of PoE power to a switch. It is important to understand the PoE power requirements of the 2610-PWR Series switches because if the PoE power is not planned and implemented correctly the end devices connected to the switch ports may not receive power if an internal switch PoE power supply should fail. For further information regarding the 600 RPS/EPS PoE capabilities, see the PoE Planning and Implementation Guide and the ProCurve 600/610 External Power Supplies Installation and Getting Started Guide, which is on the ProCurve Web site at www.hp.com/go/procurve/manuals, (See page 1-13). For redundant AC power, connect the 600 RPS/EPS to the switch using one of the six supplied RPS cables. RPS cables are 1.25 meters (4.10 feet) in length. For redundant or additional PoE power, connect the 600 RPS/EPS to the switch using one of the two supplied EPS cables. EPS cables are 2.00 meters (6.56 feet) in length. Operating Characteristics of the 610 EPS (J8169A) The 610 EPS does not have any RPS ports and can not supply RPS power. It has four EPS Ports. You can connect one to four ProCurve PoE capable switches to provide PoE power as a primary or backup source. Two in Pair A and two in Pair B. Power is equally shared between the EPS ports in pair A (that is, port A1 and A2) and between the EPS ports in pair B (port B1 and B2) 2-20 Installing the Switch Installation Procedures Each pair can provide a maximum of 408 watts of PoE power to a switch if only one port is used. If the second port of a pair is used, then both ports supply 204 watts each. Again, it is important to understand the PoE power requirements of the switches. For further information regarding the 610 EPS PoE capabilities, see the PoE Planning and Implementation Guide, which is on the ProCurve Web site at www.hp.com/go/procurve/manuals, (See page 1-13). 600 RPS/EPS LEDs For a complete description of the LEDs see the documentation that came with the 600 RPS/EPS. ■ Device Connected ■ Power Status RPS Power Status LED RPS Device Connected LED RPS Power: 12V RPS 3 EPS Device Connected LED ! backup to one connected device. Lowest-numbered port has priority. R3 RPS 4 R4 RPS 5 R5 RPS 6 R6 EPS Power: 50V EPS 1 EPS Power Status LED 370W total for PoE applications. Power is shared when E1 both ports are used. Device EPS 2 E2 Connected Power Status Line: 50/60 Hz. 10 0 - 240 V~ 9.1A (9,1A) Figure 2-12. RPS/EPS status LEDs 2-21 Installing the Switch The 600 RPS/EPS LEDs are located on the back of the device. These LEDs are duplicated on the front of the device for your convenience. The following graphic shows an example of the back of the 600 EPS/RPS. There are two green LEDs for each RPS and EPS port: Installing the Switch Installation Procedures Installing the Switch The following states provide status of the RPS and EPS ports. Fault (located on the front) Device Connected Power Status Message Off Off Off Nothing Connected On or Off Off On Not a valid state - should never happen Off On Off Switch is connected, RPS is available but not required Off On On RPS is powering the connected device Flashing Off Flashing RPS/EPS port is in fault condition Off On Flashing Switch is requesting power, RPS can not provide it. (N/A for EPS) 600 RPS/EPS Connectivity The following illustration shows an example of connectivity between an RPS/ EPS device and a switch device as a redundant AC power supply. Remove the cover of the RPS input port and connect the RPS cable to the 600 RPS/EPS then to the 2610 switch. Switch RPS output port RPS input port Figure 2-13. Connecting a 600 RPS/EPS to a 2610 RPS 2-22 Installing the Switch Installation Procedures The following illustration shows an example of connectivity between an RPS/ EPS device and six switch devices as a redundant AC power supply. RPS port 1 highest priority RPS port 6 lowest priority 600 RPS/EPS Installing the Switch 2610-PWR switches Figure 2-14. Connecting a 600 RPS/EPS to multiple 2610s RPS The 600 RPS/EPS can provide backup power for up to six switches. The 600 RPS/EPS can supply power to only one connected and failed switch at a time. In the illustration above, the switch connected to RPS port 1 has the highest priority and the switch connected to RPS port 6 has the lowest priority. When multiple switches fail, a switch connected to a higher priority port always receives power before a switch connected to a lower priority port. 2-23 Installing the Switch Installation Procedures The following illustration demonstrates an example of connectivity between an RPS/EPS device and a Switch device as a PoE power supply. Switch EPS output Installing the Switch EPS input port Figure 2-15. Connecting a 600 RPS/EPS to a 2610 EPS 610 EPS LEDs Power and Fault LEDs Backup Power Port LEDs hp procurve EPS Ports Pair A (408 W total for PoE applications) 610 eps EPS A1 J8169A Power A1 Device Connected Power Status EPS A2 EPS Ports A2 Pair B (408 W total for PoE applications) EPS B1 B1 Device Connected Power Status EPS B2 B2 Backup Power Ports Status Internal Power Status Fan/Temp Status Fault 610 EPS EPS Port LEDs In Ready Out Ready EPS Ports: 50V 8.3A max each. Fan/Temp Status flash = Temperature too high Fan/Temp Status + Fault flash = Fan failure Fan/Temp Status LED Internal Power Status LED Power Status LED Device Connected LED Figure 2-16. EPS status LEDs For a complete description of the LEDs see the documentation that came with the 610 EPS. For redundant or additional PoE power, connect the 610 EPS to the switch using one of the four supplied EPS cables. EPS cables are 2.00 meters (6.56 feet) in length. The following illustration demonstrates an example of connectivity between a 610 EPS device and two Switch devices as a PoE power supply. 2-24 Installing the Switch Installation Procedures hp procurve 610 eps Pair A (408 W total for PoE applications) EPS Ports EPS A1 J8169A A1 Device Connected Power Status EPS Ports Pair B (408 W total for PoE applications) A2 B1 EPS A2 EPS B1 Device Connected Power Status B2 EPS B2 Backup Power Ports Status Power Internal Power Status EPS Ports: 50V Out Ready 8.3A max each. Fan/Temp Status flash = Temperature too high Fan/Temp Status + Fault flash = Fan failure Figure 2-17. Connecting a 610 EPS to two 2610s EPS In this example each switch receives 408 watts of PoE power. Each switch is connected to one port of each pair. If the two switches were connected to both ports of a pair, both ports of pair A for example, then each switch receives 204 watts. See the following example. The following illustration demonstrates an example of connectivity between a 610 EPS device and four Switch devices as a PoE power supply. In this example each switch receives 204 watts of PoE power. hp procurve EPS Ports Pair A (408 W total for PoE applications) 610 eps EPS A1 J8169A A1 Device Connected Power Status EPS Ports Pair B (408 W total for PoE applications) A2 EPS A2 B1 EPS B1 Device Connected Power Status B2 EPS B2 Backup Power Ports Status Power Internal Power Status Fan/Temp Status Fault In Ready Out Ready EPS Ports: 50V 8.3A max each. Fan/Temp Status flash = Temperature too high Fan/Temp Status + Fault flash = Fan failure Figure 2-18. Connecting a 610 EPS to four 2610s EPS 2-25 Installing the Switch In Ready Fan/Temp Status Fault Installing the Switch Installation Procedures 8. (Optional) Connect a Console to the Switch The 2610 Switches have a full-featured, easy to use console interface for performing switch management tasks including the following: ■ monitor switch and port status and observe network activity statistics ■ modify the switch’s configuration to optimize switch performance, enhance network traffic control, and improve network security ■ read the event log and access diagnostic tools to help in troubleshooting ■ download new software to the switch ■ add passwords to control access to the switch from the console, web browser interface, and network management stations Installing the Switch The console can be accessed through these methods: ■ Out-of-band: The 2610 Switches come with a serial cable for connecting a PC or VT-100 terminal, to be used as a console, directly to the switch. ■ In-Band: Access the console using Telnet from a PC or UNIX station on the network, and a VT-100 terminal emulator. This method requires that you first configure the switch with an IP address and subnet mask by using either out-of-band console access or through DHCP/Bootp. For more information on IP addressing and on starting a Telnet session, see chapter 3, “Configuring the Switch”, in the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/ go/procurve/manuals, (See page 1-13). The 2610 Switches can simultaneously support one out-of-band console session through the Console Port and in-band Telnet console sessions. Terminal Configuration To connect a console to the switch, configure the PC terminal emulator as a DEC VT-100 (ANSI) terminal or use a VT-100 terminal, and configure either one to operate with these settings: ■ any baud rate from 1200 to 115200 (the switch senses the speed) ■ 8 data bits, 1 stop bit, no parity, and flow control set to Xon/Xoff ■ for the Windows Terminal program, also disable (uncheck) the “Use Function, Arrow, and Ctrl Keys for Windows” option ■ for the Hilgraeve HyperTerminal program, select the “Terminal keys” option for the “Function, arrow, and ctrl keys act as” parameter If you want to operate the console using a different configuration, make sure you change the settings on both the terminal and on the switch so they are compatible. Change the switch settings first, then change the terminal settings, then reboot the switch and reestablish the console session. 2-26 Installing the Switch Installation Procedures Direct Console Access To connect a console to the switch, follow these steps: 1. 3. Turn on the terminal or PC’s power and, if using a PC, start the PC terminal program. Console port Console cable supplied with the switch Installing the Switch 2. Connect the PC or terminal to the switch’s Console Port using the console cable included with the switch. (If your PC or terminal has a 25-pin serial connector, first attach a 9-pin to 25-pin straight-through adapter at one end of the console cable.) PC running a terminal emulator program, or a VT-100 terminal Figure 2-19. Connecting the console cable Press [Enter] two or three times and you will see the copyright page and the message “Press any key to continue”. Press a key, and you will then see the switch console command (CLI) prompt, for example: ProCurve Switch # If you want to continue with console management of the switch at this time, see chapter 3, “Getting Started With Switch Configuration” for some basic configuration steps. For more detailed information, refer to the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/ go/procurve/manuals, (See page 1-13). 2-27 Installing the Switch Sample Network Topologies for Non-PWR Switches Sample Network Topologies for Non-PWR Switches This section shows a few sample network topologies in which the Switch 2610 is implemented. For more topology information, see the ProCurve networking products Web site, www.hp.com/go/procurve/manuals. Installing the Switch As a Desktop Switch Server Twisted-pair straight-through or crossover cables Switch 2610-48 Gigabit fiber-optic cable to backbone PCs and peripherals Figure 2-20. Basic desktop configuration The 2610 Switches are designed to be used primarily as desktop switches to which end nodes, printers, other peripherals, and servers are directly connected, as shown in the above illustration. The end node devices are connected to the switch by straight-through or crossover twisted-pair cables. Either cable type can be used because of the Auto-MDIX feature on the 2610 Switches ports. 2-28 Installing the Switch Sample Network Topologies for Non-PWR Switches As a Segment Switch Category 5e twisted-pair straight-through or crossover cable for 1000 Mbps connection to server Server with Gigabit Ethernet NIC Category 5e twisted-pair straightthrough or crossover cable for 1000 Mbps connection to backbone Switch 2610-48 Installing the Switch Gigabit fiber-optic cable Switch 2610-48 Switch 2610-48 Twisted-pair straight-through cables to end nodes PCs, printers, and local servers Figure 2-21. Segment network configuration The 2610 Switches also work well as segment switches. That is, with their high performance, they can be used for interconnecting network segments— simply connect the network devices that form those segments to the 2610 Switches. In the illustration above, two “Fast Ethernet” switches with PCs, printers, and local servers attached, are both connected to a Switch 2610-48. The devices attached to the two desktop switches can now communicate with each other through the switch. They can also all communicate with the server that is connected to a 1000Base-T port on the switch. 2-29 Installing the Switch Sample Network Topologies for Non-PWR Switches Because the 2610 Switches have the Auto-MDIX feature, the connections between the switches, and between the switch and end nodes or servers can be through category 5 straight-through or crossover twisted-pair cable. Category 3 or 4 cable can also be used if the connection is 10 Mbps only. In all cases, the device ports must be configured to auto negotiate the link characteristics for this feature to work. The switch, in turn, can be connected to a network backbone through fiberoptic cabling connected to a Gigabit-SX, -LX, or -LH mini-GBIC. Now, all the devices on these network segments can access other network resources that are connected elsewhere on the network backbone. Always remember when connecting fiber-optics that all components match in specification. Installing the Switch Connecting to a Backbone Switch To Gigabit-Ethernet backbone Switch 5406zl Switch 2610-48 Gigabit fiber-optic cables Switch 2610-48 Switch 2610-48 Figure 2-22. Networking to a gigabit ethernet backbone 2-30 Switch 2610-48 Installing the Switch Sample Network Topologies for Non-PWR Switches The simpler desktop and segment networks shown in the previous two examples can easily be combined and expanded. For example, you could use a ProCurve Switch 5406zl to interconnect each of your smaller switched workgroups to form a larger switched network. All the devices in this network can communicate with each other. For example, with Gigabit-SX Mini-GBICs installed in a Mini-GBIC Module, in the Switch 5406zl, the entire switched topology could be connected to a campus backbone, as shown in the illustration above. Note In the Figure 2-22, the 1000 Mbps fiber-optic connection between the Switch 2610s and the Switch 5406zl is by way of a Gigabit-SX mini-GBIC installed in the Switch 2610s connected to a Gigabit SX mini-GBIC installed in the miniGBIC Module in the 5406zl. Installing the Switch 2-31 Installing the Switch Sample Network Topologies for PWR Switches Sample Network Topologies for PWR Switches This section shows a few sample network topologies for implementing the Switch 2610-PWR Series. For more topology information, see the ProCurve networking products Web site, www.hp.com/go/procurve/manuals. As a Desktop Switch Implementing PoE 600 RPS/EPS Installing the Switch RPS cable EPS cable Server 2610-48-PWR Gigabit fiber-optic cable to backbone IP Telephones Twisted-pair straight-through or crossover cables PCs and peripherals Figure 2-23. Basic desktop configuration with external power The Switch 2610-PWR Series are also designed to be used as desktop switches to which end nodes, printers and other peripherals, and servers are directly connected, as shown in the above illustration. Except now these switches can supply PoE power to end devices such as IP telephones. As shown in the above illustration the IP telephones can be connected in line, that is, between the switch and the end device, in this case a PC. The IP telephones have two ports, one in and one out. Therefore the phone receives voice and power from the switch and the PC can send and receive data through the phone to the switch. The end node devices are connected to the switch by straight-through or crossover twisted-pair cables. Either cable type can be used because of the Auto-MDIX feature on the Switch 2610-PWR Series. 2-32 Installing the Switch Sample Network Topologies for PWR Switches As a Segment Switch Implementing PoE Category 5e twisted-pair straight-through or crossover cable for 1000 Mbps connection to server Server with Gigabit Ethernet NIC Switch 2610-48 Non-PWR 600 RPS/EPS Gigabit fiber-optic cable uplink Switch 2610-48PWR Switch 2610-48-PWR Wireless Access Points PCs, printers, and local servers Figure 2-24. Segment network configuration with PoE switches As shown in the illustration above, the IP telephones have been inserted in between the Switch 2610-48-PWR and the PCs, and wireless access points (WAPs) have been connected to another Switch 2610-48-PWR. Both the telephones and WAPs will receive PoE power from each of the switches. Only devices directly connected to the PWR switches can receive PoE power. Devices connected to a non-PWR segment switch cannot receive PoE power. 2-33 Installing the Switch Twisted-pair straightthrough or crossover cables Installing the Switch Sample Network Topologies for PWR Switches Connecting to a Backbone Switch Implementing PoE To Gigabit-Ethernet backbone Installing the Switch Switch 5406zl Switch 2610-48 non-PWR Gigabit fiber-optic cable Switch 2610-48 non-PWR 600 RPS/EPS Switch 2610-48-PWR Switch 261048-PWR Wireless Access Point Figure 2-25. Networking PoE switches to a gigabit ethernet backbone 2-34 Installing the Switch Sample Network Topologies for PWR Switches Stacking the Switch Switch 2610 and 2610-PWR Series devices can be connected together, through standard network connections, and managed through a single IP address. Up to 16 switches can be connected together in such a “virtual stack”. You identify a Switch 2610 or 2610-PWR Series device as the “Commander” and give that switch an IP address. Up to 15 other switches in the network can then easily be configured as Members of the stack and managed through the Commander’s IP address. The management includes Telnet access and web browser interface access to the Commander and to each Member switch through the Commander. 2-35 Installing the Switch For more information on stacking your switch, see the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/go/ procurve/manuals, (See page 1-13). 3 Configuring the Switch This chapter is a guide for using the console Switch Setup screen to quickly assign an IP (Internet Protocol) address and subnet mask to the switch, set a Manager password, and, optionally, configure other basic features. For more information on using the switch console and the web browser interface, please see the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/go/procurve/manuals, (See page 1-13). Recommended Minimal Configuration Many other features can be configured through the switch’s console interface, to optimize the switch’s performance, to enhance your control of the network traffic, and to improve network security. Once an IP address has been configured on the switch, these features can be accessed more conveniently through a remote Telnet session, through the switch’s web browser interface, and from an SNMP network management station running a network management program. For a listing of switch features available with and without an IP address, refer to “How IP Addressing Affects Switch Operation” in the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/go/procurve/manuals, (See page 1-13). For more information on IP addressing, refer to “IP Configuration” in the Management and Configuration Guide. Note By default, the switch is configured to acquire an IP address configuration from a DHCP or Bootp server. To use DHCP/Bootp instead of the manual method described in this chapter, see “DHCP/Bootp Operation” in the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/go/procurve/manuals, (See page 1-13). 3-1 Configuring the Switch In the factory default configuration, the switch has no IP (Internet Protocol) address and subnet mask, and no passwords. In this state, it can be managed only through a direct console connection. To manage the switch through inband (networked) access, you should configure the switch with an IP address and subnet mask compatible with your network. Also, you should configure a Manager password to control access privileges from the console and web browser interface. Other parameters in the Switch Setup screen can be left at their default settings or you can configure them with values you enter. Configuring the Switch Recommended Minimal Configuration Using the Console Setup Screen The quickest and easiest way to minimally configure the switch for management and password protection in your network is to use a direct console connection to the switch, start a console session, and access the Switch Setup screen. 1. Using the method described in the preceding section, connect a terminal device to the switch and display the switch console command line interface (CLI) prompt (the default display). The CLI prompt appears, for example: ProCurve# 2. At the prompt, enter the setup command to display the Switch Setup screen. The following illustration shows the Setup screen with the default settings. u 2007 Configuring the Switch 2610-48 Figure 3-1. Example console setup screen 3. Use the [Tab] key to select the Manager Password field and enter a manager password of up to 16 printable ASCII characters. 4. [Tab] to the IP Config (DHCP/Bootp) field and use the Space bar to select the Manual option. 3-2 5. [Tab] to the IP Address field and enter the IP address that is compatible with your network. 6. [Tab] to the Subnet Mask field and enter the subnet mask used for your network. 7. Press [Enter], then [S] (for Save). Configuring the Switch Recommended Minimal Configuration Here is some information on the fields in the Setup screen. For more information on these fields, see the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/go/procurve/manuals, (See page 1-13): Default System Name blank Optional; up to 25 characters, including spaces System Contact blank Optional; up to 48 characters, including spaces Manager Password blank Recommended; up to 16 characters (no blank spaces) Logon Default CLI The default setting selects the command line interface for console access. The alternative is the menu interface. Time Zone 0 (none) Optional; 1440 to -1440. The number of minutes your location is to the West (-) or East (+) of GMT. Community Name public Default setting recommended. Spanning Tree Enabled No Default setting recommended unless STP is already running on your network or the switch will be used in complex network topologies. Default Gateway blank Optional; Enter the IP address of the next-hop gateway node if network traffic needs to be able to reach off-subnet destinations. Time Sync Method None Optional; The protocol the switch uses to acquire a time signal. The options are SNTP and TimeP. TimeP Mode Disabled Optional; The method the switch uses to acquire the TimeP server address. IP Config (DHCP/Bootp) DHCP/Bootp Set to Manual unless a DHCP/Bootp server is used on your network to configure IP addressing. IP Address xxx.xxx.xxx.xxx Recommended; If you set IP Config to Manual, then enter an IP address compatible with your network. Note: The IP address and subnet mask assigned for the switch must be compatible with the IP addressing used in your network. For more information on IP addressing, see the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/go/procurve/manuals, (See page 1-13). Subnet Mask xxx.xxx.xxx.xxx Recommended; If you entered an IP address, then enter a subnet mask compatible with your network. Where to Go From Here The above procedure configures your switch with a Manager password, IP address, and subnet mask. As a result, with the proper network connections, you can now manage the switch from a PC equipped with Telnet, and/or a web browser interface. 3-3 Configuring the Switch Parameter Configuring the Switch Recommended Minimal Configuration Some basic information on managing your switch is included in the next section. For more information on the console, web browser, and SNMP management interfaces and all the features that can be configured on the Series 2610 Switches, see the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/go/procurve/manuals, (See page 113). Configuring the Switch To Recover from a Lost Manager Password: If you cannot start a console session at the manager level because of a lost Manager password, you can clear all passwords and user names by getting physical access to the switch and pressing and holding the Clear button for a full second. 3-4 Configuring the Switch Using the IP Address for Remote Switch Management Using the IP Address for Remote Switch Management With your switch, you can use the switch’s IP address to manage the switch from any PC that is on the same subnet as the switch. You can use either a Telnet session or a standard web browser to manage the switch. Starting a Telnet Session To access the switch through a Telnet session, follow these steps: 1. Make sure the switch is configured with an IP address and that the switch is reachable from the PC that is running the Telnet session (for example, by using a Ping command to the switch’s IP address). 2. Start the Telnet program on a PC that is on the same subnet as the switch and connect to the switch’s IP address. 3. You will see the copyright page and the message “Press any key to continue”. Press a key, and you will then see the switch console command (CLI) prompt, for example: ProCurve# Starting a Web Browser Session The 2610 Switches can be managed through a graphical interface that you can access from any PC or workstation on the network by running your web browser and typing in the switch’s IP address as the URL. No additional software installation is required to make this interface available; it is included in the switch’s onboard software. A typical web browser interface screen is shown in the next illustration. 3-5 Configuring the Switch Enter help or ? to see a list of commands that can be executed at the prompt. Entering any command followed by help provides more detailed context help information about the command. Entering any command followed by ? displays a list of options that are available at that point in the command entry. Configuring the Switch Using the IP Address for Remote Switch Management ProCurve Switch 2610-48 - xl Status: Information J9088A ProCurve Switch 2610-48 xl PoE Status Configuring the Switch Figure 3-2. Example web browser session For more information on using the web browser interface, please see the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/go/procurve/manuals, (See page 1-13). An extensive help system is also available for the web browser interface. To access the help system though, the subnet on which the switch is installed must have access to the internet. 3-6 4 Troubleshooting This chapter describes how to troubleshoot your ProCurve 2610 Switches. This document describes troubleshooting mostly from a hardware perspective. You can perform more in-depth troubleshooting on these devices using the software tools available with the switches, including the fullfeatured console interface, the built-in web browser interface, and ProCurve Manager, the SNMP-based network management tool. For more information, see the chapter “Troubleshooting” in the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/go/procurve/manuals, (See page 1-13). This chapter describes the following: ■ basic troubleshooting tips (page 4-1) ■ diagnosing with the LEDs (page 4-4) ■ proactive networking tools (page 4-9) ■ hardware diagnostic tests (page 4-10) ■ restoring the factory default configuration (page 4-12) ■ downloading new software to the Series 2610 Switches (page 4-13) ■ HP Customer Support Services (page 4-13) Basic Troubleshooting Tips Most problems are caused by the following situations. Check for these items first when starting your troubleshooting: ■ • If the connected device is also configured to Auto, the switch will automatically negotiate both link speed and communication mode. • If the connected device has a fixed configuration, for example 100 Mbps, at half or full duplex, the switch will automatically sense the link speed, but will default to a communication mode of half duplex. 4-1 Troubleshooting Connecting to devices that have a fixed full-duplex configuration. The RJ-45 ports are configured as “Auto”. That is, when connecting to attached devices, the switch operates in one of two ways to determine the link speed and the communication mode (half duplex or full duplex): Troubleshooting Basic Troubleshooting Tips Caution Because the 2610 Switches behave in this way (in compliance with the IEEE 802.3 standard), if a device connected to the switch has a fixed configuration at full duplex, the device will not connect correctly to the switch. The result will be high error rates and very inefficient communications between the switch and the device. Ensure all devices connected to the 2610 Switches are configured to auto negotiate, or are configured to connect at half duplex (all hubs are configured this way, for example). ■ Faulty or loose cables. Look for loose or obviously faulty connections. If the cables appear to be OK, make sure the connections are snug. If that does not correct the problem, try a different cable. ■ Non-standard cables. Non-standard and miswired cables may cause network collisions and other network problems, and can seriously impair network performance. Use a new correctly-wired cable or compare your cable to the cable in appendix B, “Switch Ports and Network Cables” for pinouts and correct cable wiring. A category 5 cable tester is a recommended tool for every 100Base-TX and 1000Base-T network installation. ■ Improper Network Topologies. It is important to make sure you have a valid network topology. Common topology faults include excessive cable length and excessive repeater delays between end nodes. If you have network problems after recent changes to the network, change back to the previous topology. If you no longer experience the problems, the new topology is probably at fault. Sample topologies are shown at the end of chapter 2 in this book, and some topology configuration guidelines can be found online at the ProCurve Web site, www.hp.com/go/procurve/ manuals. In addition, you should make sure your network topology contains no data path loops. Between any two end nodes, there should be only one active cabling path at any time. Data path loops will cause broadcast storms that will severely impact your network performance. Troubleshooting For your Switch, if you wish to build redundant paths between important nodes in your network to provide some fault tolerance, you should enable Spanning Tree Protocol support on the switch. This ensures that only one of the redundant paths is active at any time, thus avoiding data path loops. Spanning Tree can be enabled through the switch console or the web browser interface. The 2610 Switches also support Trunking, which allows multiple network cables to be used for a single network connection without causing a data path loop. For more information on Spanning Tree and Trunking, see the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/go/procurve/manuals, (See page 1-13). 4-2 Troubleshooting Basic Troubleshooting Tips ■ Check the port configuration. A port on your switch may not be operating as you expect because it has been put into a “blocking” state by Spanning Tree, GVRP (automatic VLANs), or LACP (automatic trunking). (Note that the normal operation of the Spanning Tree, GVRP, and LACP features may put the port in a blocking state.) Or, the port just may have been configured as disabled through software. Use the switch console to determine the port’s configuration and verify that there is not an improper or undesired configuration of any of the switch features that may be affecting the port. For more information, see the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/go/procurve/manuals, (See page 1-13). For more information on possible network problems and their solutions, refer to the technical note “Troubleshooting LAN Performance and Intermittent Connectivity Problems”, which can be found on the ProCurve Web site, www.hp.com/go/procurve/,in the Reference Library section, A-Z Index. Troubleshooting 4-3 Troubleshooting Diagnosing with the LEDs Diagnosing with the LEDs Table 4-1 shows LED patterns on the switch that indicate problem conditions for general switch operation troubleshooting. Table 4-2 shows LED patterns that indicate problem conditions for PoE troubleshooting. LED patterns for General Switch Troubleshooting 1. Check in the table for the LED pattern you see on your switch. 2. Refer to the corresponding diagnostic tip on the next few pages. Table 4-1. LED Error Indicators Troubleshooting LED Pattern Indicating Problems Power Fault RPS EPS Test Fan Port Link LED Diagnostic Tips Off with power cord plugged in 1 1 1 1 1 1 ➊ On Prolonged On 1 1 Prolonged On 1 1 ➋ On Flashing2 1 1 Flashing2 1 1 ➌ On Flashing2 1 1 Off Flashing2 1 ➍ On Flashing2 1 1 Flashing2 1 Flashing2 ➎ On Off 1 1 Off 1 Off with cable connected ➏ On Off 1 1 Off 1 On, but the port is not communicating ➐ On Flashing Flashing Flashing 1 1 ➑ 1 2 4-4 This LED is not important for the diagnosis. The flashing behavior is an on/off cycle once every 1.6 seconds, approximately. Troubleshooting Diagnosing with the LEDs Diagnostic Tips: Problem Solution ➊ The switch is not plugged into an active AC power source, or the switch’s power supply may have failed. 1. Verify the power cord is plugged into an active power source and to the switch. Make sure these connections are snug. 2. Try power cycling the switch by unplugging and plugging the power cord back in. 3. If the Power LED is still not on, verify the AC power source works by plugging another device into the outlet. Or try plugging the switch into a different outlet or try a different power cord. If the power source and power cord are OK and this condition persists, the switch power supply may have failed. Call your HP-authorized LAN dealer, or use the electronic support services from HP to get assistance. See the Customer Support/Warranty booklet for more information. ➋ A switch hardware failure has occurred. All the LEDs will stay on indefinitely. Try power cycling the switch. If the fault indication reoccurs, the switch may have failed. Call your HP-authorized LAN dealer, or use the electronic support services from HP to get assistance. See the Customer Support/Warranty booklet for more information. ➌ The switch has experienced a software failure during self test. 1. Try resetting the switch by pressing the Reset button on the front of the switch, or by power cycling the switch. 2. If the fault indication reoccurs, attach a console to the switch (as indicated in chapter 2) and configure it to operate at 9600 baud. Then, reset the switch. Messages should appear on the console screen and in the console log identifying the error condition. You can view the console log at that point by selecting it from the console Main Menu or by typing “Show log” at the Manager command prompt (#). If necessary to resolve the problem, contact your HP-authorized LAN dealer, or use the electronic support services from HP to get assistance. See the Customer Support/ Warranty booklet for more information. ➍ One of the switch cooling fans may have failed. Try disconnecting power from the switch and wait a few moments. Then reconnect the power to the switch and check the LEDs again. If the error indication reoccurs, one of the fans has failed. In switches with multiple fans the switch may continue to operate under this condition if the ambient temperature does not exceed normal room temperature, but for best operation, the switch should be replaced. Contact your HP-authorized LAN dealer, or use the electronic support services from HP to get assistance. See the Customer Support/Warranty booklet for more information. ➎ The network port for which the LED is flashing has experienced a self test or initialization failure. Try power cycling the switch. If the fault indication reoccurs, the switch port may have failed. Call your HP-authorized LAN dealer, or use the electronic support services from HP to get assistance. See the Customer Support/Warranty booklet for more information. If the port is a mini-GBIC, verify that it is one of the mini-GBICs supported by the switch. Unsupported mini-GBICs will be identified with this fault condition. The supported mini-GBICs are listed in Chapter 2, “Installing the Switch” on page 2-17. The mini-GBICs are also tested when they are “hot-swapped”—installed or changed while the switch is powered on. To verify the port has failed, remove and reinstall the mini-GBIC without powering off the switch. If the port fault indication reoccurs, you will have to replace the mini-GBIC. Check the event log to see why the mini-GBIC failed. continued on the next page 4-5 Troubleshooting Tip Troubleshooting Diagnosing with the LEDs Tip Problem Solution ➏ The network connection is not working properly. Try the following procedures: • For the indicated port, verify that both ends of the cabling, at the switch and the connected device, are connected properly. • Verify the connected device and switch are both powered on and operating correctly. • Verify you have used the correct cable type for the connection: – For twisted-pair connections to the fixed 10/100 or 10/100/1000 ports, if the port is configured to “Auto” (auto negotiate), either straight-through or crossover cables can be used because of the switch’s “Auto-MDIX” feature and the Auto MDI/MDIX feature of the 10/100/1000-T port. Note: If the switch port configuration is changed to one of the fixed configuration options (for example, 100 Mbps/Full Duplex), then the port operates as MDI-X only and you must use the correct type of cable for the connection. In general, for connecting an end node (MDI port) to the switch, use straight-through cable; for connecting to MDI-X ports on hubs, other switches, and routers, use crossover cable. • • • • Troubleshooting • 4-6 – For fiber-optic connections, verify the transmit port on the switch is connected to the receive port on the connected device, and the switch receive port is connected to the transmit port on the connected device. For the dual-personality 10/100/1000-T ports, be sure a mini-GBIC is not installed in the associated slot. For 1000Base-T connections, verify the network cabling complies with the IEEE 802.3ab standard. The cable should be installed according to the ANSI/TIA/EIA-568-A-5 specifications. Cable testing should comply with the stated limitations for Attenuation, Near-End Crosstalk, Far-End Crosstalk, Equal-Level Far-End Crosstalk (ELFEXT), Multiple Disturber ELFEXT, and Return Loss. The cable verification process must include all patch cables from any end devices, including the switch, to any patch panels in the cabling path. Verify the port has not been disabled through a switch configuration change. You can use the console interface, or, if you have configured an IP address on the switch, use the web browser interface to determine the state of the port and re-enable the port if necessary. Verify the switch port configuration matches the configuration of the attached device. For example, if the switch port is configured as “Auto”, the port on the attached device also MUST be configured as “Auto”. Depending on the port type, twisted-pair or fiberoptic, if the configurations don’t match, the results could be a very unreliable connection, or no link at all. If the other procedures don’t resolve the problem, try using a different port or a different cable. Troubleshooting Diagnosing with the LEDs Tip Problem Solution ➐ The port may be improperly configured, or the port may be in a “blocking” state by the normal operation of the Spanning Tree, LACP, or IGMP features. Use the switch console to see if the port is part of a dynamic trunk (through the LACP feature) or to see if Spanning Tree is enabled on the switch, and to see if the port may have been put into a “blocking” state by those features. The show lacp command displays the port status for the LACP feature; the show spanning-tree command displays the port status for Spanning Tree. Also check the Port Status screen using the show interfaces command to see if the port has been configured as “disabled”. Other switch features that may affect the port operation include VLANs and IGMP. Use the switch console to see how the port is configured for these features. For software troubleshooting tips, see the chapter “Troubleshooting” in the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/go/ procurve/manuals, (See page 1-13). Ensure also, that the device at the other end of the connection is indicating a good link to the switch. If it is not, the problem may be with the cabling between the devices or the connectors on the cable. ➑ RPS or EPS is connected but has experienced a fault. Refer to the ProCurve 600/610 External Power Supplies documentation. Troubleshooting 4-7 Troubleshooting Diagnosing with the LEDs LED Patterns for PoE Troubleshooting If the PoE Status LED is flashing, that indicates a problem with the delivery of PoE power out one or more switch ports. Press the LED Mode button to put the switch into PoE mode and the port LEDs will show which ports are experiencing the problem. The following tables identify the specific problems that are shown by the LEDs. 1. Check in the table for the LED pattern you see on your switch. 2. Refer to the corresponding diagnostic tip. Table 4-2. LED Error Indicators LED Pattern Indicating Problems Fault PoE Status Port Link Port Mode Diagnostic Tips Off Fast Flash Orange Slow Flash Green Off ➊ Slow Flash Slow Flash Orange Slow Flash Green Off ➋ Diagnostic Tips: Troubleshooting Tip 4-8 Problem Solution ➊ PoE oversubscription condition. All available PoE power is already taken by higher-priority ports. If possible add additional PoE power, or redefine port priorities. ➋ PoE hardware fault. A switch hardware component that is involved with PoE power delivery has failed. The switch must be replaced. Troubleshooting Proactive Networking Proactive Networking The ProCurve 2610 Switches have built-in management capabilities that proactively help you manage your network including: ■ finding and helping you fix the most common network error conditions (for example, faulty network cabling, and non-standard network topologies) ■ informing you of the problem with clear, easy-to-understand messages ■ recommending network configuration changes to enhance the performance of your network The following interfaces provide tests, indicators, and an event log that can be used to monitor the switch and its network connections and to help you take advantage of these proactive networking features: ■ A graphical web browser interface you can use to manage your switch from a PC running a supported web browser, for example Microsoft Internet Explorer, and Netscape Communicator. ■ A full-featured easy-to-use console interface you can access by connecting a standard terminal or PC running a terminal emulator to the switch’s console port. The cable to make that connection is provided with your switch. The console interface is also accessible through a Telnet connection. For more information on using these software tools to diagnose and manage your switch, see the “Troubleshooting” chapter in the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/go/ procurve/manuals, (See page 1-13). Troubleshooting 4-9 Troubleshooting Hardware Diagnostic Tests Hardware Diagnostic Tests Testing the Switch by Resetting It If you believe the switch is not operating correctly, you can reset the switch to test its circuitry and operating code. To reset a switch, either: ■ unplug and plug in the power cord (power cycling) ■ press the Reset button on the front of the switch Power cycling the switch and pressing the Reset button both cause the switch to perform its power-on self test, which almost always will resolve any temporary operational problems. These reset processes also cause any network traffic counters to be reset to zero, and cause the System Up Time timer to reset to zero. Checking the Switch LEDs The self test passes if the Fault and Self Test LEDs on the front of the switch go off after approximately 50 seconds. If these LEDs stay on longer than 60 seconds or begin flashing, there may be a problem with the switch. See “Diagnosing With the LEDs” on page 4-4 for information on interpreting the LED patterns. Checking Console Messages Troubleshooting Useful diagnostic messages may be displayed on the console screen when the switch is reset. As described in chapter 2 under step 7, Connect a Console to the Switch connect a PC running a VT-100 terminal emulator program or a standard VT-100 terminal to the switch’s Console Port and configure it to run at 9600 baud, and with the other terminal communication settings shown on “Configuring the Switch”. Then, when you reset the switch, note the messages that are displayed. Additionally, you can check the switch event log, which can be accessed from the console using the show log command, or from the console Main Menu after entering the Menu command. 4-10 Troubleshooting Hardware Diagnostic Tests Testing Twisted-Pair Cabling Network cables that fail to provide a link or provide an unreliable link between the switch and the connected network device may not be compatible with the IEEE 802.3 Type 10Base-T, 100Base-TX, or 1000Base-T standards. The twistedpair cables attached to the switch must be compatible with the appropriate standards. To verify your cable is compatible with these standards, use a qualified cable test device. Testing Switch-to-Device Network Communications You can perform the following communication tests to verify the network is operating correctly between the switch and any connected device that can respond correctly to the communication test. ■ Link Test—a physical layer test that sends IEEE 802.2 test packets to any device identified by its MAC address ■ Ping Test—a network layer test used on IP networks that sends test packets to any device identified by its IP address These tests can be performed through the switch console interface from a terminal connected to the switch or through a Telnet connection, or from the switch’s web browser interface. For more information, see the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/ go/procurve/manuals, (See page 1-13). Testing End-to-End Network Communications Both the switch and the cabling can be tested by running an end-to-end communications test—a test that sends known data from one network device to another through the switch. For example, if you have two PCs on the network that have LAN adapters between which you can run a link-level test or Ping test through the switch, you can use this test to verify that the entire communication path between the two PCs is functioning correctly. See your LAN adapter documentation for more information on running a link test or Ping test. Troubleshooting 4-11 Troubleshooting Restoring the Factory Default Configuration Restoring the Factory Default Configuration As part of your troubleshooting process on the Switch, it may become necessary to return the switch configuration to the factory default settings. This clears any passwords, clears the console event log, resets the network counters to zero, performs a complete self test, and reboots the switch into its factory default configuration including deleting the IP address, if one is configured. Note This process removes all switch configuration changes that you have made from the factory default settings. This includes, for example, configuration of VLANs, Spanning Tree, trunks, and stacking. Returning the configuration of these features to their factory default settings (usually disabling them) may result in network connectivity issues. If the switch has a valid configuration, and you are restoring the factory default settings for a reason other than configuration problems, you should save the switch configuration prior to performing the factory default reset. Then, after the reset and resolution of the original problem, you can restore the saved configuration to the switch. For both the save and restore processes, you can use the console copy command. For more information on this command, see the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/go/procurve/manuals, (See page 1-13). You can restore the factory default configuration either on the switch itself, or through the switch console. Troubleshooting To execute the factory default reset on the switch, perform these steps: 1. Using pointed objects, simultaneously press both the Reset and Clear buttons on the front of the switch. The power and fault lights come on. 2. Continue to press the Clear button while releasing the Reset button. 3. When the Self Test LED begins to flash, release the Clear button. The switch will then complete its self test and begin operating with its configuration restored to the factory default settings. To restore the factory default configuration using the console, execute the erase startup-config command from the console command prompt. 4-12 Troubleshooting Downloading New Switch Software Downloading New Switch Software When product enhancements occur for the 2610 Switches, new software can be downloaded to the switch through several methods, for product enhancements and new features. For more information, see the Management and Configuration Guide, which is on the ProCurve Web site at www.hp.com/ go/procurve/manuals, (See page 1-13). The new switch software would be available on the ProCurve Web site, www.hp.com/go/procurve/manuals. HP Customer Support Services If you are still having trouble with your switch, Hewlett-Packard offers support 24 hours a day, seven days a week through the use of a number of automated electronic services. See the Customer Support/Warranty booklet that came with your switch for information on how to use these services to get technical support. The ProCurve Web site, www.hp.com/go/procurve/manuals also provides up-to-date support information. Additionally, your HP-authorized network reseller can provide you with assistance, both with services that they offer and with services offered by HP. Before Calling Support Before calling your networking dealer or HP Support, to make the support process most efficient, you first should retrieve the following information: Information Item Information Location the front of the switch and on labels on the mini-GBICs • details about the switch’s status including the software (OS) version, a copy of the switch configuration, a copy of the switch Event Log, and a copy of the switch status and counters information switch console: show tech command • copy of your network topology map, including network addresses assigned to the relevant devices your network records 4-13 Troubleshooting • product identification, including mini-GBICs A Switch Specifications Switch Specifications Physical Width Depth Height Weight 2610-24 (J9085A) 44.3 cm (17.4 in) 23.5 cm (9.3 in) 4.4 cm (1.73 in) 4.63 kg (10.20 lbs) 2610-48 (J9088A) 44.3 cm (17.4 in) 23.5 cm (9.3 in) 4.4 cm (1.73 in) 4.88 kg (10.75 lbs) 2610-24/12PWR (J9086A) 44.3 cm (17.4 in) 23.5 cm (9.3 in) 4.4 cm (1.73 in) 3.4 kg (7.5 lbs) 2610-24-PWR (J9087A) 44.3 cm (17.4 in) 31.8 cm (12.5 in) 4.4 cm (1.73 in) 6.83 kg (15.05 lbs) 2610-48-PWR (J9089A) 44.3 cm (17.4 in) 34.3 cm (13.5 in) 4.4 cm (1.73 in) 7.58 kg (16.70 lbs) 2610 Non-PWR Series 2610-PWR Series Electrical AC voltage Maximum current Frequency range 2610-24 (J9085A) 100-127 volts 200-240 volts 0.75A 0.4A 50/60 Hz 50/60 Hz 2610-48 (J9088A) 100-127 volts 200-240 volts 1.25A 0.75A 50/60 Hz 50/60 Hz 2610-24/12PWR (J9086A) 100-127 volts 200-240 volts 2.5A 1.25A 50/60 Hz 50/60 Hz 2610-24-PWR (J9087A) 100-127 volts 200-240 volts 7.0A 3.5A 50/60 Hz 50/60 Hz 2610-48-PWR (J9089A) 100-127 volts 200-240 volts 7.0A 3.5A 50/60 Hz 50/60 Hz 2610 Non-PWR Series 2610-PWR Series The switch automatically adjusts to any voltage between 100-127 or 200-240 volts and either 50 or 60 Hz. A-1 Switch Specifications Switch Specifications RPS/EPS Electrical Input 2610 Non-PWR Series Input voltage Maximum current RPS Input +12 VDC 7.5A EPS Input N/A N/A Input voltage Maximum current RPS Input +12 VDC 7.5A EPS Input -50 VDC 16A 2610-PWR Series Environmental 2610 Switches Operating Non-Operating Temperature 0°C to 50°C (32°F to 122°F) -40°C to 70°C (-40°F to 158°F) Relative humidity (non-condensing) 15% to 95% at 40°C (104°F) 15% to 90% at 65°C (149°F) Maximum altitude 3.0 Km (10,000 ft)* 4.6 Km (15,000 ft) * The operating maximum altitude should not exceed that of any accessory being connected to any switch in the 2610 series. BTU Ratings Switch Model Combined BTU1 Switch only BTU 2610-24/12PWR 827 181 2610-24-PWR 2281 410 2610-48-PWR 2281 410 2610-24 Non-PoE 142 2610-48 Non-PoE 285 1 A-2 Includes switch and maximum number of PoE powered devices connected to the switch at 15.4 watts. Switch Specifications Acoustics Switch Specifications Non-PWR Switches Switch 2610-24 (J9085A) No fans. Switch 2610-48 (J9088A) Geraeuschemission LwA=36.2 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19 Noise Emission LwA=36.2 dB at virtual work space according to DIN 45635 T.19 PWR switches Switch 2610-24/12PWR (J9086A) Geraeuschemission LwA=38.4 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19 Noise Emission LwA=38.4 dB at virtual work space according to DIN 45635 T.19 Switch 2610-24-PWR (J9087A) Geraeuschemission LwA=56.6 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19 Noise Emission LwA=56.6 dB at virtual work space according to DIN 45635 T.19 Switch 2610-48-PWR (J9089A) Geraeuschemission LwA=56.6 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19 Noise Emission LwA=56.6 dB at virtual work space according to DIN 45635 T.19 RPS/EPS Connectors ■ EPS connector: A 2x7 Molex Micro-Fit connector should be used for EPS connection. ■ RPS connector: A 2x7 connector is provided for external RPS connection on the power supply module. Cable Length ■ EPS cables are 2.0 meters (6.56 feet) in length ■ RPS cables are 1.25 meters (4.10 feet) in length A-3 Switch Specifications Switch Specifications Safety Complies with: ■ EN60950-1/IEC60950-1 ■ CSA 22.2 No. 60950-1 ■ UL 60950-1 Table A-1. Technology standards and safety compliance Laser safety information Technology 10 100 1000-T A-4 Compatible with these IEEE standards EN/IEC standard compliance SFP ("mini-GBIC") Lasers IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TX, IEEE 802.3ab 1000BASE-T 100-FX IEEE 802.3u 100BASE-FX EN/IEC 60825 Class 1 Laser Product Laser Klasse 1 100-BX IEEE 802.3ah 100BASE-BX10 EN/IEC 60825 Class 1 Laser Product Laser Klasse 1 1000-SX IEEE 802.3z 1000BASE-SX EN/IEC 60825 Class 1 Laser Product Laser Klasse 1 1000-LX IEEE 802.3z 1000BASE-LX EN/IEC 60825 Class 1 Laser Product Laser Klasse 1 1000-LH (not an IEEE standard) EN/IEC 60825 Class 1 Laser Product Laser Klasse 1 1000-BX IEEE 802.3ah 1000BASE-BX10 EN/IEC 60825 Class 1 Laser Product Laser Klasse 1 B Cabling and Technology Information This appendix includes network cable information for cables that should be used with the Switch 2610, including minimum pin-out information and specifications for twisted-pair cables. Note Cabling specifications Table B-1. 10 Mbps Operation Category 3, 4, or 5 100-ohm unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable, complying with IEEE 802.3 10Base-T specifications. 100 Mbps Operation Category 5 100-ohm UTP or STP cable, complying with IEEE 802.3u 100Base-TX specifications. 1000 Mbps Operation Category 5 100-ohm 4-pair UTP or STP cable, complying with IEEE 802.3ab 1000Base-T specifications—Category 5e or better is recommended. See note on 1000Base-T Cable Requirements on page B-2. Twisted-pair copper Multimode fiber 62.5/125 μm or 50/125 μm (core/cladding) diameter, low metal content, graded index fiber-optic cables, complying with the ITU-T G.651 and ISO/IEC 793-2 Type A1b or A1a standards respectively.1 Single mode fiber 9/125 μm (core/cladding) diameter, low metal content fiber-optic cables, complying with the ITU-T G.652 and ISO/IEC 793-2 Type B1 standards. 1 A mode conditioning patch cord may be needed for some Gigabit-LX installations. See “Mode Conditioning Patch Cord” on page B-3 for more information. B-1 Cabling and Technology Information Incorrectly wired cabling is the most common cause of problems for LAN communications. ProCurve recommends that you work with a qualified LAN cable installer for assistance with your cabling requirements. Cabling and Technology Information Note on 1000Base-T Cable Requirements. The Category 5 networking cables that work for 100Base-TX connections should also work for 1000Base-T, as long as all four-pairs are connected. But, for the most robust connections you should use cabling that complies with the Category 5e specifications, as described in Addendum 5 to the TIA-568-A standard (ANSI/ TIA/EIA-568-A-5). Cabling and Technology Information Because of the increased speed provided by 1000Base-T (Gigabit-T), network cable quality is more important than for either 10Base-T or 100Base-TX. Cabling plants being used to carry 1000Base-T networking must comply with the IEEE 802.3ab standards. In particular, the cabling must pass tests for Attenuation, Near-End Crosstalk (NEXT), and Far-End Crosstalk (FEXT). Additionally, unlike the cables for 100Base-TX, the 1000Base-T cables must pass tests for Equal-Level Far-End Crosstalk (ELFEXT) and Return Loss. When testing your cabling, be sure to include the patch cables that connect the switch and other end devices to the patch panels on your site. The patch cables are frequently overlooked when testing cable and they must also comply with the cabling standards. Technology distance specifications Table B-2. Technology Supported cable type Multimode fiber modal bandwidth Supported distances 100-FX multimode fiber any up to 2,000 meters 100-BX single mode fiber N/A 0.5 - 10,000 meters 1000-T twisted-pair copper N/A up to 100 meters 1000-SX multimode fiber 160 MHz*km 200 MHz*km 400 MHz*km 500 MHz*km 2 - 220 meters 2 - 275 meters 2 - 500 meters 2 - 550 meters 1000-LX multimode fiber single mode fiber 400 MHz*km 500 MHz*km N/A 2 - 550 meters 2 - 550 meters 2 - 10,000 meters 1000-LH single mode fiber N/A 10 - 70,000 meters1 1000-BX single mode fiber N/A 0.5 - 10,000 meters 1 For distances less than 20km, a 10dB attenuator must be used. For distances between 20km and 40km, a 5dB attenuator must be used. Attenuators can be purchased from most cable vendors. B-2 Cabling and Technology Information Mode Conditioning Patch Cord The following information applies to installations in which multimode fiberoptic cables are connected to a Gigabit-LX port. Multimode cable has a design characteristic called “Differential Mode Delay”, which requires the transmission signals be “conditioned” to compensate for the cable design and thus prevent resulting transmission errors. The patch cord consists of a short length of single mode fiber cable coupled to graded-index multimode fiber cable on the transmit side, and only multimode cable on the receive side. The section of single mode fiber is connected in such a way that it minimizes the effects of the differential mode delay in the multimode cable. Note Most of the time, if you are using good quality graded-index multimode fiber cable that adheres to the standards listed in Appendix B, there should not be a need to use mode conditioning patch cords in your network. This is especially true if the fiber runs in your network are relatively short. Installing the Patch Cord As shown in the illustration below, connect the patch cord to the ProCurve transceiver with the section of single mode fiber plugged in to the Tx (transmit) port. Then, connect the other end of the patch cord to your network cabling patch panel, or directly to the network multimode fiber. If you connect the patch cord directly to the network cabling, you may need to install a female-to-female adapter to allow the cables to be connected together. B-3 Cabling and Technology Information Under certain circumstances, depending on the cable used and the lengths of the cable runs, an external Mode Conditioning Patch Cord may need to be installed between the Gigabit-LX transmitting device and the multimode network cable to provide the transmission conditioning. If you experience a high number of transmission errors on those ports, usually CRC or FCS errors, you may need to install one of these patch cords between the fiber-optic port in your switch and your multimode fiber-optic network cabling, at both ends of the network link. Cabling and Technology Information Twisted-Pair Cable/Connector Pin-Outs To network multimode cabling Cabling and Technology Information The multimode cable in the patch cord must match the characteristics of your network cable Tx Rx Gigabit-LX port LC Connector Mode Conditioning Patch Cord Single-mode section plugs into Tx port on Gigabit-LX Transceiver or Gigabit-LX mini-GBIC Figure B-1. Connecting a patch cord Make sure you purchase a patch cord that has appropriate connectors on each end, and has multimode fibers that match the characteristics of the multimode fiber in your network. Most important, the core diameter of the multimode patch cord must match the core diameter of the multimode cable infrastructure (either 50 or 62.5 microns). Twisted-Pair Cable/Connector Pin-Outs The Auto-MDIX Feature: In the default configuration, “Auto”, the fixed 10/ 100Base-TX ports on the 2610 Switches all automatically detect the type of port on the connected device and operate as either an MDI or MDI-X port, whichever is appropriate. So for any connection, a straightthrough twisted-pair cable can be used—you no longer have to use crossover cables, although crossover cables can also be used for any of the connections. (The 10/100/1000-T ports support the IEEE 802.3ab standard, which includes the “Auto MDI/MDI-X” feature, which operates the same way.) If you connect a 2610 or 2610-PWR Switch twisted-pair port to another switch or hub, which typically have MDI-X ports, the 2610 Switch port automatically operates as an MDI port. If you connect it to an end node, such as a server or PC, which typically have MDI ports, the 2610 Switch port operates as an MDIX port. In all cases, you can use standard straight-through cables or crossover cables. If you happen to use a correctly wired crossover cable, though, the switch will still be able to automatically detect the MDI/MDI-X operation and link correctly to the connected device. B-4 Cabling and Technology Information Twisted-Pair Cable/Connector Pin-Outs Other Wiring Rules: All twisted-pair wires used for 10 Mbps, and 100 Mbps operation must be twisted through the entire length of the cable. The wiring sequence must conform to EIA/TIA 568-B (not USOC). See “Twisted-Pair Cable Pin Assignments” later in this appendix for a listing of the signals used on each pin. ■ For 1000Base-T connections, all four pairs of wires in the cable must be available for data transmission. See “Note on 1000Base-T Cable Requirements” on page B-2 for more information on 1000Base-T cabling. ■ For 10 Mbps connections to the ports, you can use Category 3, 4, or 5 unshielded twisted-pair cable, as supported by the IEEE 802.3 Type 10Base-T standard. ■ For 100 Mbps connections to the ports, use 100-ohm Category 5 UTP or STP cable only, as supported by the IEEE 802.3u Type 100Base-TX standard. ■ For 1000 Mbps connections, 100-ohm Category 5e or better cabling is recommended. ■ To provide Power over Ethernet to the access point, all 4 pairs must be connected for any network cable attached to this port; the cable must meet ISO/DIS 11801 Class D requirements and IEEE 802.3af requirements. B-5 Cabling and Technology Information ■ Cabling and Technology Information Twisted-Pair Cable/Connector Pin-Outs Straight-through Twisted-Pair Cable for 10 Mbps or 100 Mbps Network Connections Because of the Auto-MDIX operation of the 10/100 ports on the switch, for all network connections, to PCs, servers or other end nodes, or to hubs or other switches, you can use straight-through cables. If any of these ports are given a fixed configuration, for example 100 Mbps/ Full Duplex, the ports operate as MDI-X ports, and straight-through cables must be then used for connections to PC NICs and other MDI ports. Cabling and Technology Information Cable Diagram Note Pins 1 and 2 on connector “A” must be wired as a twisted pair to pins 1 and 2 on connector “B”. Pins 3 and 6 on connector “A” must be wired as a twisted pair to pins 3 and 6 on connector “B”. Pins 4, 5, 7, and 8 are not used in this application, although they may be wired in the cable. . Pin Assignments B-6 Switch End (MDI-X) Computer, Transceiver, or Other End Signal Pins Pins Signal receive + receive transmit + transmit - 1 2 3 6 1 2 3 6 transmit + transmit receive + receive - Cabling and Technology Information Twisted-Pair Cable/Connector Pin-Outs Crossover Twisted-Pair Cable for 10 Mbps or 100 Mbps Network Connection The Auto-MDIX operation of the 10/100 ports on the switch also allows you to use crossover cables for all network connections, to PCs, servers or other end nodes, or to hubs or other switches. If any of these ports are given a fixed configuration, for example 100 Mbps/ Full Duplex, the ports operate as MDI-X ports, and crossover cables must be then used for connections to hubs or switches or other MDI-X network devices. Cable Diagram Cabling and Technology Information Note Pins 1 and 2 on connector “A” must be wired as a twisted pair to pins 3 and 6 on connector “B”. Pins 3 and 6 on connector “A” must be wired as a twisted pair to pins 1 and 2 on connector “B”. Pins 4, 5, 7, and 8 are not used in this application, although they may be wired in the cable. Pin Assignments Switch End (MDI-X) Hub or Switch Port, or Other MDI-X Port End Signal Pins Pins Signal receive + receive transmit + transmit - 1 2 3 6 6 3 2 1 transmit transmit + receive receive + B-7 Cabling and Technology Information Twisted-Pair Cable/Connector Pin-Outs Straight-Through Twisted-Pair Cable for 1000 Mbps Network Connections 1000Base-T connections require that all four pairs of wires be connected. Cabling and Technology Information Cable Diagram Note Pins 1 and 2 on connector “A” must be wired as a twisted pair to pins 1 and 2 on connector “B”. Pins 3 and 6 on connector “A” must be wired as a twisted pair to pins 3 and 6 on connector “B”. Pins 4 and 5 on connector “A” must be wired as a twisted pair to pins 4 and 5 on connector “B”. Pins 7 and 8 on connector “A” must be wired as a twisted pair to pins 7 and 8 on connector “B”. . Pin Assignments For 1000Base-T operation, all four pairs of wires are used for both transmit and receive. B-8 C Safety and EMC Regulatory Statements Safety Information ! Documentation reference symbol. If the product is marked with this symbol, refer to the product documentation to get more information about the product. WARNING A WARNING in the manual denotes a hazard that can cause injury or death. Caution A Caution in the manual denotes a hazard that can damage equipment. Do not proceed beyond a WARNING or Caution notice until you have understood the hazardous conditions and have taken appropriate steps. For LAN cable grounding: ■ If your LAN covers an area served by more than one power distribution system, be sure their safety grounds are securely interconnected. ■ LAN cables may occasionally be subject to hazardous transient voltages (such as lightning or disturbances in the electrical utilities power grid). Handle exposed metal components of the network with caution. Servicing There are no user-serviceable parts inside these products. Any servicing, adjustment, maintenance, or repair must be performed only by service-trained personnel. These products do not have a power switch; they are powered on when the power cord is plugged in. C-1 Safety and EMC Regulatory Statements Grounding These are safety class I products and have protective earthing terminals. There must be an uninterruptible safety earth ground from the main power source to the product's input wiring terminals, power cord, or supplied power cord set. Whenever it is likely that the protection has been impaired, disconnect the power cord until the ground has been restored. Safety and EMC Regulatory Statements Informations concernant la sécurité Informations concernant la sécurité ! Symbole de référence à la documentation. Si le produit est marqué de ce symbole, reportez-vous à la documentation du produit afin d'obtenir des informations plus détaillées. WARNING Dans la documentation, un WARNING indique un danger susceptible d'entraîner des dommages corporels ou la mort. Caution Un texte de mise en garde intitulé Caution indique un danger susceptible de causer des dommages à l'équipement. Ne continuez pas au-delà d'une rubrique WARNING ou Caution avant d'avoir bien compris les conditions présentant un danger et pris les mesures appropriées. Cet appareil est un produit de classe I et possède une borne de mise à la terre. La source d'alimentation principale doit être munie d'une prise de terre de sécurité installée aux bornes du câblage d'entrée, sur le cordon d'alimentation ou le cordon de raccordement fourni avec le produit. Lorsque cette protection semble avoir été endommagée, débrancher le cordon d'alimentation jusqu'à ce que la mise à la terre ait été réparée. Safety and EMC Regulatory Statements Mise à la terre du câble de réseau local: ■ si votre réseau local s'étend sur une zone desservie par plus d'un système de distribution de puissance, assurez-vous que les prises de terre de sécurité soient convenablement interconnectées. ■ Les câbles de réseaux locaux peuvent occasionnellement être soumis à des surtensions transitoires dangereuses (telles que la foudre ou des perturbations dans le réseau d'alimentation public). Manipulez les composants métalliques du réseau avec précautions. Aucune pièce contenue à l'intérieur de ce produit ne peut être réparée par l'utilisateur. Tout dépannage, réglage, entretien ou réparation devra être confié exclusivement à un personnel qualifié. Cet appareil ne comporte pas de commutateur principal; la mise sous tension est effectuée par branchement du cordon d'alimentation. C-2 Safety and EMC Regulatory Statements Hinweise zur Sicherheit Hinweise zur Sicherheit ! Symbol für Dokumentationsverweis. Wenn das Produkt mit diesem Symbol markiert ist, schlagen Sie bitte in der Produktdokumentation nach, um mehr Informationen über das Produkt zu erhalten. WARNING Eine WARNING in der Dokumentation symbolisiert eine Gefahr, die Verletzungen oder sogar Todesfälle verursachen kann. Caution Caution in der Dokumentation symbolisiert eine Gefahr, die dis Gerät beschädigen kann. Fahren Sie nach dem Hinweis WARNING oder Caution erst fort, nachdem Sie den Gefahrenzustand verstanden und die entsprechenden Maßnahmen ergriffen haben. Dies ist ein Gerät der Sicherheitsklasse I und verfügt über einen schützenden Erdungsterminal. Der Betrieb des Geräts erfordert eine ununterbrochene Sicherheitserdung von der Hauptstromquelle zu den Geräteingabeterminals, den Netzkabeln oder dem mit Strom belieferten Netzkabelsatz voraus. Sobald Grund zur Annahme besteht, daß der Schutz beeinträchtigt worden ist, das Netzkabel aus der Wandsteckdose herausziehen, bis die Erdung wiederhergestellt ist. ■ Wenn Ihr LAN ein Gebiet umfaßt, das von mehr als einem Stromverteilungssystem beliefert wird, müssen Sie sich vergewissern, daß die Sicherheitserdungen fest untereinander verbunden sind. ■ LAN-Kabel können gelegentlich gefährlichen Übergangsspannungen ausgesetzt werden (beispielsweise durch Blitz oder Störungen in dem Starkstromnetz des Elektrizitätswerks). Bei der Handhabung exponierter Metallbestandteile des Netzwerkes Vorsicht walten lassen. Dieses Gerät enthält innen keine durch den Benutzer zu wartenden Teile. Wartungs-, Anpassungs-, Instandhaltungs- oder Reparaturarbeiten dürfen nur von geschultem Bedienungspersonal durchgeführt werden. Dieses Gerät hat keinen Netzschalter; es wird beim Anschließen des Netzkabels eingeschaltet. C-3 Safety and EMC Regulatory Statements Für LAN-Kabelerdung: Safety and EMC Regulatory Statements Considerazioni sulla sicurezza Considerazioni sulla sicurezza ! Simbolo di riferimento alla documentazione. Se il prodotto è contrassegnato da questo simbolo, fare riferimento alla documentazione sul prodotto per ulteriori informazioni su di esso. WARNING La dicitura WARNINGdenota un pericolo che può causare lesioni o morte. Caution La dicituraCaution denota un pericolo che può danneggiare le attrezzature. Non procedere oltre un avviso di WARNING o di Cautionprima di aver compreso le condizioni di rischio e aver provveduto alle misure del caso. Questo prodotto è omologato nella classe di sicurezza I ed ha un terminale protettivo di collegamento a terra. Dev'essere installato un collegamento a terra di sicurezza, non interrompibile che vada dalla fonte d'alimentazione principale ai terminali d'entrata, al cavo d'alimentazione oppure al set cavo d'alimentazione fornito con il prodotto. Ogniqualvolta vi sia probabilità di danneggiamento della protezione, disinserite il cavo d'alimentazione fino a quando il collegaento a terra non sia stato ripristinato. Safety and EMC Regulatory Statements Per la messa a terra dei cavi LAN: ■ se la vostra LAN copre un'area servita da più di un sistema di distribuzione elettrica, accertatevi che i collegamenti a terra di sicurezza siano ben collegati fra loro; ■ i cavi LAN possono occasionalmente andare soggetti a pericolose tensioni transitorie (ad esempio, provocate da lampi o disturbi nella griglia d'alimentazione della società elettrica); siate cauti nel toccare parti esposte in metallo della rete. Nessun componente di questo prodotto può essere riparato dall'utente. Qualsiasi lavoro di riparazione, messa a punto, manutenzione o assistenza va effettuato esclusivamente da personale specializzato. Questo apparato non possiede un commutatore principale; si mette scotto tensione all'inserirsi il cavo d'alimentazione. C-4 Safety and EMC Regulatory Statements Consideraciones sobre seguridad Consideraciones sobre seguridad ! Símbolo de referencia a la documentación. Si el producto va marcado con este símbolo, consultar la documentación del producto a fin de obtener mayor información sobre el producto. WARNING Una WARNING en la documentación señala un riesgo que podría resultar en lesiones o la muerte. Caution Una Caution en la documentación señala un riesgo que podría resultar en averías al equipo. No proseguir después de un símbolo de WARNING o Caution hasta no haber entendido las condiciones peligrosas y haber tomado las medidas apropiadas. Este aparato se enmarca dentro de la clase I de seguridad y se encuentra protegido por una borna de puesta a tierra. Es preciso que exista una puesta a tierra continua desde la toma de alimentación eléctrica hasta las bornas de los cables de entrada del aparato, el cable de alimentación o el juego de cable de alimentación suministrado. Si existe la probabilidad de que la protección a tierra haya sufrido desperfectos, desenchufar el cable de alimentación hasta haberse subsanado el problema. ■ Si la LAN abarca un área cuyo suministro eléctrico proviene de más de una red de distribución de electricidad, cerciorarse de que las puestas a tierra estén conectadas entre sí de modo seguro. ■ Es posible que los cables de la LAN se vean sometidos de vez en cuando a voltajes momentáneos que entrañen peligro (rayos o alteraciones en la red de energía eléctrica). Manejar con precaución los componentes de metal de la LAN que estén al descubierto. Este aparato no contiene pieza alguna susceptible de reparación por parte del usuario. Todas las reparaciones, ajustes o servicio de mantenimiento debe realizarlos solamente el técnico. Este producto no tiene interruptor de potencia; se activa cuando se enchufa el cable de alimentación. C-5 Safety and EMC Regulatory Statements Puesta a tierra del cable de la red local (LAN): Safety and EMC Regulatory Statements Safety Information (Japan) Safety and EMC Regulatory Statements Safety Information (Japan) Japan Power Cord Warning C-6 Safety and EMC Regulatory Statements Safety Information (China) Safety Information (China) Safety and EMC Regulatory Statements C-7 Safety and EMC Regulatory Statements EMC Regulatory Statements EMC Regulatory Statements U.S.A. FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. Operation of this equipment in a residential area may cause interference in which case the user will be required to correct the interference at his own expense. Canada This product complies with Class A Canadian EMC requirements. Safety and EMC Regulatory Statements Australia/New Zealand This product complies with Australia/New Zealand EMC Class A requirements. Japan VCCI Class A C-8 Safety and EMC Regulatory Statements EMC Regulatory Statements Korea Taiwan Safety and EMC Regulatory Statements ᳝↦ǃ᳝ᆇ⠽䋼/ܗ㋴ঞ݊䞣㸼 ձ✻Ё lj⬉ᄤֵᙃѻક∵ᶧࠊㅵ⧚ࡲ⊩NJ ᳝↦ǃ᳝ᆇ⠽䋼ܗ㋴ 䚼ӊৡ⿄ 䬝 (Cd) ݁Ӌ䫀 (Cr(VI)) ⒈㘨㣃 (PBB) ⒈ҷѠ㣃䝮 3%'( 䪙 (Pb) ∲ (Hg) ᴎㆅ/䱨ᵓ/݊ᅗ䞥 ሲล᭭䚼ӊ 0 0 0 0 0 0 ॄࠋ⬉䏃㒘ӊ (PCA) X 0 0 0 0 0 㒓 X 0 0 0 0 0 ⬉㓚/⬉㒓 X 0 0 0 0 0 ⬉∴ 0 0 0 0 0 0 亢/亢Ⲭ 0 0 0 0 0 0 ⬉⑤/⬉⑤䗖䜡఼ X 0 0 0 0 0 ᅝ㺙ᬃᶊ/݊ᅗ䰘 ӊ 0 0 0 0 0 0 CF व 0 0 0 0 0 0 2㸼⼎ℸ䚼ӊՓ⫼ⱘ᠔᳝ৠ㉏ᴤ᭭Ёℸ⾡᳝↦᳝ᆇ⠽䋼ⱘ䞣ഛԢѢ SJ/T11363-2006 㾘ᅮⱘ䰤ࠊ㽕∖DŽ X:㸼⼎ℸ䚼ӊՓ⫼ⱘ㟇ᇥϔ⾡ৠ㉏ᴤ᭭Ёˈℸ⾡᳝↦᳝ᆇ⠽䋼ⱘ䞣催Ѣ SJ/T11363-2006 㾘ᅮⱘ䰤ࠊ㽕∖DŽ ⊼˖᠔ᓩ⫼ⱘ⦃ֱՓ⫼ᳳ䰤ᷛ䆄ḍѻકⱘℷᐌ᪡Փ⫼ᴵӊ˄བ⏽ᑺᑺ˅⹂ᅮDŽ 䰸䴲᳝ᷛᯢˈℸ⬉ᄤֵᙃѻક∵ᶧࠊᷛ䆄䗖⫼Ѣ᠔᳝ProCurve Networking by HP ѻકDŽ This information is required by the People’s Republic of China as per their legislation titled “Management Methods for Controlling Pollution by Electronic Information Products”. C-9 Safety and EMC Regulatory Statements EMC Regulatory Statements European Community DECLARATION OF CONFORMITY according to ISO/IEC 17050-1 and EN17050-1 ______________________________________________________________________ Supplier's Name: Hewlett-Packard Company Supplier's Address: 8000 Foothills Blvd. Roseville, CA 95747-5502 U.S.A. DOC#: RSVLC-0701x-02062009 (x=A,B,C or D) declares, that the product ProCurve Switch 2610-24, ProCurve Switch 2610-24/12-PWR, Product Name2: ProCurve Switch 2610-24-PWR, ProCurve Switch 2610-48, ProCurve Switch 2610-48-PWR Product Model(s): J9085A, J9086A, J9087A, J9088A, J9089A Regulatory Model Number1: RSVLC-0701x (x=A,B,C or D) Product Options: J8168A, J8169A*, J4858B/C, J4859B/C, J4860B/C * For use with J9086A, J9087A and J9089A only. conforms to the following Product Specifications and Regulations: Safety and EMC Regulatory Statements EMC: Class A EN 55022:2006 EN 55024:1998 +A1:2001 +A2:2003 EN 61000-3-2:2006 EN 61000-3-3:1995 +A1:2001 +A2 :2005 FCC CFR47 Part 15 Safety: EN 60950-1:2001 + A11:2004 IEC 60950-1:2001 EN 60825-1:1994 +A1+A2 / IEC 60825-1:1993 +A2 Class 1 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference; and, (2) this device must accept any interference received, including interference that may cause undesired operation. The product herewith complies with the requirements of the Low Voltage Directive 2006/95/EC, the EMC Directive 2004/108/EC, and carries the CE-marking accordingly. Additional Information: 1) This product is assigned a Regulatory Model Number which stays with the regulatory aspects of the design. The Regulatory Model Number is the main product identifier in the regulatory documentation and test reports. This number should not be confused with the marketing name or the product numbers. 2) This product was tested with HP branded products only. Roseville,06 February 2009 European Contact: Your local Hewlett-Packard Sales and Service Office or Hewlett-Packard GmbH, Department HQTRE, Herrenberger Straße 140, D-71034 Böblingen (FAX: + 49-7031-14-3143) C-10 D Recycle Statements Waste Electrical and Electronic Equipment (WEEE) Statements Disposal of Waste Equipment by Users in Private Household in the European Union This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product. Likvidace zařízení soukromými domácími uživateli v Evropské unii Tento symbol na produktu nebo balení označuje výrobek, který nesmí být vyhozen spolu s ostatním domácím odpadem. Povinností uživatele je předat takto označený odpad na předem určené sběrné místo pro recyklaci elektrických a elektronických zařízení. Okamžité třídění a recyklace odpadu pomůže uchovat přírodní prostředí a zajistí takový způsob recyklace, který ochrání zdraví a životní prostředí člověka. Další informace o možnostech odevzdání odpadu k recyklaci získáte na příslušném obecním nebo městském úřadě, od firmy zabývající se sběrem a svozem odpadu nebo v obchodě, kde jste produkt zakoupili. Seadmete jäätmete kõrvaldamine eramajapidamistes Euroopa Liidus See tootel või selle pakendil olev sümbol näitab, et kõnealust toodet ei tohi koos teiste majapidamisjäätmetega kõrvaldada. Teie kohus on oma seadmete jäätmed kõrvaldada, viies need elektri- ja elektroonikaseadmete jäätmete ringlussevõtmiseks selleks ettenähtud kogumispunkti. Seadmete jäätmete eraldi kogumine ja ringlussevõtmine kõrvaldamise ajal aitab kaitsta loodusvarasid ning tagada, et ringlussevõtmine toimub viisil, mis kaitseb inimeste tervist ning keskkonda. Lisateabe saamiseks selle kohta, kuhu oma seadmete jäätmed ringlussevõtmiseks viia, võtke palun ühendust oma kohaliku linnakantselei, majapidamisjäätmete kõrvaldamise teenistuse või kauplusega, kust Te toote ostsite. D-1 Recycle Statements Bortskaffelse af affald fra husstande i den Europæiske Union Hvis produktet eller dets emballage er forsynet med dette symbol, angiver det, at produktet ikke må bortskaffes med andet almindeligt husholdningsaffald. I stedet er det dit ansvar at bortskaffe kasseret udstyr ved at aflevere det på den kommunale genbrugsstation, der forestår genvinding af kasseret elektrisk og elektronisk udstyr. Den centrale modtagelse og genvinding af kasseret udstyr i forbindelse med bortskaffelsen bidrager til bevarelse af naturlige ressourcer og sikrer, at udstyret genvindes på en måde, der beskytter både mennesker og miljø. Yderligere oplysninger om, hvor du kan aflevere kasseret udstyr til genvinding, kan du få hos kommunen, den lokale genbrugsstation eller i den butik, hvor du købte produktet. Recycle Statements Waste Electrical and Electronic Equipment (WEEE) Statements Laitteiden hävittäminen kotitalouksissa Euroopan unionin alueella Jos tuotteessa tai sen pakkauksessa on tämä merkki, tuotetta ei saa hävittää kotitalousjätteiden mukana. Tällöin hävitettävä laite on toimitettava sähkölaitteiden ja elektronisten laitteiden kierrätyspisteeseen. Hävitettävien laitteiden erillinen käsittely ja kierrätys auttavat säästämään luonnonvaroja ja varmistamaan, että laite kierrätetään tavalla, joka estää terveyshaitat ja suojelee luontoa. Lisätietoja paikoista, joihin hävitettävät laitteet voi toimittaa kierrätettäväksi, saa ottamalla yhteyttä jätehuoltoon tai liikkeeseen, josta tuote on ostettu. Élimination des appareils mis au rebut par les ménages dans l'Union européenne Le symbole apposé sur ce produit ou sur son emballage indique que ce produit ne doit pas être jeté avec les déchets ménagers ordinaires. Il est de votre responsabilité de mettre au rebut vos appareils en les déposant dans les centres de collecte publique désignés pour le recyclage des équipements électriques et électroniques. La collecte et le recyclage de vos appareils mis au rebut indépendamment du reste des déchets contribue à la préservation des ressources naturelles et garantit que ces appareils seront recyclés dans le respect de la santé humaine et de l'environnement. Pour obtenir plus d'informations sur les centres de collecte et de recyclage des appareils mis au rebut, veuillez contacter les autorités locales de votre région, les services de collecte des ordures ménagères ou le magasin dans lequel vous avez acheté ce produit. Entsorgung von Altgeräten aus privaten Haushalten in der EU Das Symbol auf dem Produkt oder seiner Verpackung weist darauf hin, dass das Produkt nicht über den normalen Hausmüll entsorgt werden darf. Benutzer sind verpflichtet, die Altgeräte an einer Rücknahmestelle für Elektro- und Elektronik-Altgeräte abzugeben. Die getrennte Sammlung und ordnungsgemäße Entsorgung Ihrer Altgeräte trägt zur Erhaltung der natürlichen Ressourcen bei und garantiert eine Wiederverwertung, die die Gesundheit des Menschen und die Umwelt schützt. Informationen dazu, wo Sie Rücknahmestellen für Ihre Altgeräte finden, erhalten Sie bei Ihrer Stadtverwaltung, den örtlichen Müllentsorgungsbetrieben oder im Geschäft, in dem Sie das Gerät erworben haben Απόρριψη άχρηστου εξοπλισμού από χρήστες σε ιδιωτικά νοικοκυριά στην Ευρωπαϊκή Ένωση Το σύμβολο αυτό στο προϊόν ή τη συσκευασία του υποδεικνύει ότι το συγκεκριμένο προϊόν δεν πρέπει να διατίθεται μαζί με τα άλλα οικιακά σας απορρίμματα. Αντίθετα, είναι δική σας ευθύνη να απορρίψετε τον άχρηστο εξοπλισμό σας παραδίδοντάς τον σε καθορισμένο σημείο συλλογής για την ανακύκλωση άχρηστου ηλεκτρικού και ηλεκτρονικού εξοπλισμού. Η ξεχωριστή συλλογή και ανακύκλωση του άχρηστου εξοπλισμού σας κατά την απόρριψη θα συμβάλει στη διατήρηση των φυσικών πόρων και θα διασφαλίσει ότι η ανακύκλωση γίνεται με τρόπο που προστατεύει την ανθρώπινη υγεία και το περιβάλλον. Για περισσότερες πληροφορίες σχετικά με το πού μπορείτε να παραδώσετε τον άχρηστο εξοπλισμό σας για ανακύκλωση, επικοινωνήστε με το αρμόδιο τοπικό γραφείο, την τοπική υπηρεσία διάθεσης οικιακών απορριμμάτων ή το κατάστημα όπου αγοράσατε το προϊόν. Recycle Statements Készülékek magánháztartásban történő selejtezése az Európai Unió területén A készüléken, illetve a készülék csomagolásán látható azonos szimbólum annak jelzésére szolgál, hogy a készülék a selejtezés során az egyéb háztartási hulladéktól eltérő módon kezelendő. A vásárló a hulladékká vált készüléket köteles a kijelölt gyűjtőhelyre szállítani az elektromos és elektronikai készülékek újrahasznosítása céljából. A hulladékká vált készülékek selejtezéskori begyűjtése és újrahasznosítása hozzájárul a természeti erőforrások megőrzéséhez, valamint biztosítja a selejtezett termékek környezetre és emberi egészségre nézve biztonságos feldolgozását. A begyűjtés pontos helyéről bővebb tájékoztatást a lakhelye szerint illetékes önkormányzattól, az illetékes szemételtakarító vállalattól, illetve a terméket elárusító helyen kaphat. D-2 Recycle Statements Waste Electrical and Electronic Equipment (WEEE) Statements Smaltimento delle apparecchiature da parte di privati nel territorio dell'Unione Europea Questo simbolo presente sul prodotto o sulla sua confezione indica che il prodotto non può essere smaltito insieme ai rifiuti domestici. È responsabilità dell'utente smaltire le apparecchiature consegnandole presso un punto di raccolta designato al riciclo e allo smaltimento di apparecchiature elettriche ed elettroniche. La raccolta differenziata e il corretto riciclo delle apparecchiature da smaltire permette di proteggere la salute degli individui e l'ecosistema. Per ulteriori informazioni relative ai punti di raccolta delle apparecchiature, contattare l'ente locale per lo smaltimento dei rifiuti, oppure il negozio presso il quale è stato acquistato il prodotto. Nolietotu iekārtu iznīcināšanas noteikumi lietotājiem Eiropas Savienības privātajās mājsaimniecībās Šāds simbols uz izstrādājuma vai uz tā iesaiņojuma norāda, ka šo izstrādājumu nedrīkst izmest kopā ar citiem sadzīves atkritumiem. Jūs atbildat par to, lai nolietotās iekārtas tiktu nodotas speciāli iekārtotos punktos, kas paredzēti izmantoto elektrisko un elektronisko iekārtu savākšanai otrreizējai pārstrādei. Atsevišķa nolietoto iekārtu savākšana un otrreizējā pārstrāde palīdzēs saglabāt dabas resursus un garantēs, ka šīs iekārtas tiks otrreizēji pārstrādātas tādā veidā, lai pasargātu vidi un cilvēku veselību. Lai uzzinātu, kur nolietotās iekārtas var izmest otrreizējai pārstrādei, jāvēršas savas dzīves vietas pašvaldībā, sadzīves atkritumu savākšanas dienestā vai veikalā, kurā izstrādājums tika nopirkts. Vartotojų iš privačių namų ūkių įrangos atliekų šalinimas Europos Sąjungoje Šis simbolis ant gaminio arba jo pakuotės rodo, kad šio gaminio šalinti kartu su kitomis namų ūkio atliekomis negalima. Šalintinas įrangos atliekas privalote pristatyti į specialią surinkimo vietą elektros ir elektroninės įrangos atliekoms perdirbti. Atskirai surenkamos ir perdirbamos šalintinos įrangos atliekos padės saugoti gamtinius išteklius ir užtikrinti, kad jos bus perdirbtos tokiu būdu, kuris nekenkia žmonių sveikatai ir aplinkai. Jeigu norite sužinoti daugiau apie tai, kur galima pristatyti perdirbtinas įrangos atliekas, kreipkitės į savo seniūniją, namų ūkio atliekų šalinimo tarnybą arba parduotuvę, kurioje įsigijote gaminį. Verwijdering van afgedankte apparatuur door privé-gebruikers in de Europese Unie Dit symbool op het product of de verpakking geeft aan dat dit product niet mag worden gedeponeerd bij het normale huishoudelijke afval. U bent zelf verantwoordelijk voor het inleveren van uw afgedankte apparatuur bij een inzamelingspunt voor het recyclen van oude elektrische en elektronische apparatuur. Door uw oude apparatuur apart aan te bieden en te recyclen, kunnen natuurlijke bronnen worden behouden en kan het materiaal worden hergebruikt op een manier waarmee de volksgezondheid en het milieu worden beschermd. Neem contact op met uw gemeente, het afvalinzamelingsbedrijf of de winkel waar u het product hebt gekocht voor meer informatie over inzamelingspunten waar u oude apparatuur kunt aanbieden voor recycling. D-3 Recycle Statements Pozbywanie się zużytego sprzętu przez użytkowników w prywatnych gospodarstwach domowych w Unii Europejskiej Ten symbol na produkcie lub jego opakowaniu oznacza, że produktu nie wolno wyrzucać do zwykłych pojemników na śmieci. Obowiązkiem użytkownika jest przekazanie zużytego sprzętu do wyznaczonego punktu zbiórki w celu recyklingu odpadów powstałych ze sprzętu elektrycznego i elektronicznego. Osobna zbiórka oraz recykling zużytego sprzętu pomogą w ochronie zasobów naturalnych i zapewnią ponowne wprowadzenie go do obiegu w sposób chroniący zdrowie człowieka i środowisko. Aby uzyskać więcej informacji o tym, gdzie można przekazać zużyty sprzęt do recyklingu, należy się skontaktować z urzędem miasta, zakładem gospodarki odpadami lub sklepem, w którym zakupiono produkt. Recycle Statements Waste Electrical and Electronic Equipment (WEEE) Statements Descarte de Lixo Elétrico na Comunidade Européia Este símbolo encontrado no produto ou na embalagem indica que o produto não deve ser descartado no lixo doméstico comum. É responsabilidade do cliente descartar o material usado (lixo elétrico), encaminhando-o para um ponto de coleta para reciclagem. A coleta e a reciclagem seletivas desse tipo de lixo ajudarão a conservar as reservas naturais; sendo assim, a reciclagem será feita de uma forma segura, protegendo o ambiente e a saúde das pessoas. Para obter mais informações sobre locais que reciclam esse tipo de material, entre em contato com o escritório da HP em sua cidade, com o serviço de coleta de lixo ou com a loja em que o produto foi adquirido. Likvidácia vyradených zariadení v domácnostiach v Európskej únii Symbol na výrobku alebo jeho balení označuje, že daný výrobok sa nesmie likvidovať s domovým odpadom. Povinnosťou spotrebiteľa je odovzdať vyradené zariadenie v zbernom mieste, ktoré je určené na recykláciu vyradených elektrických a elektronických zariadení. Separovaný zber a recyklácia vyradených zariadení prispieva k ochrane prírodných zdrojov a zabezpečuje, že recyklácia sa vykonáva spôsobom chrániacim ľudské zdravie a životné prostredie. Informácie o zberných miestach na recykláciu vyradených zariadení vám poskytne miestne zastupiteľstvo, spoločnosť zabezpečujúca odvoz domového odpadu alebo obchod, v ktorom ste si výrobok zakúpili. Odstranjevanje odslužene opreme uporabnikov v zasebnih gospodinjstvih v Evropski uniji Ta znak na izdelku ali njegovi embalaži pomeni, da izdelka ne smete odvreči med gospodinjske odpadke. Nasprotno, odsluženo opremo morate predati na zbirališče, pooblaščeno za recikliranje odslužene električne in elektronske opreme. Ločeno zbiranje in recikliranje odslužene opreme prispeva k ohranjanju naravnih virov in zagotavlja recikliranje te opreme na zdravju in okolju neškodljiv način. Za podrobnejše informacije o tem, kam lahko odpeljete odsluženo opremo na recikliranje, se obrnite na pristojni organ, komunalno službo ali trgovino, kjer ste izdelek kupili. Eliminación de residuos de equipos eléctricos y electrónicos por parte de usuarios particulares en la Unión Europea Este símbolo en el producto o en su envase indica que no debe eliminarse junto con los desperdicios generales de la casa. Es responsabilidad del usuario eliminar los residuos de este tipo depositándolos en un "punto limpio" para el reciclado de residuos eléctricos y electrónicos. La recogida y el reciclado selectivos de los residuos de aparatos eléctricos en el momento de su eliminación contribuirá a conservar los recursos naturales y a garantizar el reciclado de estos residuos de forma que se proteja el medio ambiente y la salud. Para obtener más información sobre los puntos de recogida de residuos eléctricos y electrónicos para reciclado, póngase en contacto con su ayuntamiento, con el servicio de eliminación de residuos domésticos o con el establecimiento en el que adquirió el producto. Recycle Statements Bortskaffande av avfallsprodukter från användare i privathushåll inom Europeiska Unionen Om den här symbolen visas på produkten eller förpackningen betyder det att produkten inte får slängas på samma ställe som hushållssopor. I stället är det ditt ansvar att bortskaffa avfallet genom att överlämna det till ett uppsamlingsställe avsett för återvinning av avfall från elektriska och elektroniska produkter. Separat insamling och återvinning av avfallet hjälper till att spara på våra naturresurser och gör att avfallet återvinns på ett sätt som skyddar människors hälsa och miljön. Kontakta ditt lokala kommunkontor, din närmsta återvinningsstation för hushållsavfall eller affären där du köpte produkten för att få mer information om var du kan lämna ditt avfall för återvinning. D-4 Index Numerics A AC power connector location on back of switch … 1-11 acoustic specifications … A-3 auto MDI/MDI-X operation … B-6, B-8 HP Auto-MDIX feature … B-4 B back of switch description … 1-11 power connector … 1-12 RPS input port … 1-12 backbone switch topology with … 2-30, 2-34–2-35 basic switch configuration IP address … 3-2 manager password … 3-2 subnet mask … 3-2 Switch Setup screen … 3-2 Index 10/100Base-TX ports location on switch … 1-4 1000Base-BX … B-2 fiber-optic cable specifications … B-2 1000Base-LH … B-2 fiber-optic cable specifications … B-2 1000Base-T 1000Base-T fiber-optic cable specifications … B-2 600 Redundant Power Supply … 2-19 600 RPS/EPS cables … 2-20 connectivity … 2-22 LEDs … 2-21 operating characteristics … 2-20 610 EPS cables … 2-24 connectivity … 2-25 LEDs … 2-24 operating characteristics … 2-21 610 External Power Supply … 2-19 basic troubleshooting tips … 4-1 Bootp automatic switch configuration … 3-1 for in-band access … 2-26 BTU ratings … A-2 buttons Clear button … 1-10 Reset button … 1-10 C cabinet mounting the switch in … 2-9 cable EPS cable length … 2-20 RPS cable length … 2-20 cable length specifications … A-3 cables connecting cables to switch ports … 2-16 effects of non-standard cables … 4-2 fiber-optic, specifications … B-2 infrastructure requirements … 2-6 serial, for direct console connection … 2-27 cables, twisted pair category 3, 4, 5 … B-5 cross-over cable pin-out … B-7 MDI-X to MDI connections … B-6, B-8 MDI-X to MDI-X connections … B-7 pin-outs … B-6, B-8 straight-through cable pin-out … B-6, B-8 switch-to-computer connection … B-6, B-8 switch-to-switch or hub connection … B-7 cables, twisted-pair HP Auto-MDIX feature … B-4 wiring rules … B-5 cables, twisted-pair connector pin-outs … B-4 cabling infrastructure … 2-6 Clear button deleting passwords … 1-10 description … 1-10 location on switch … 1-4, 1-10 restoring factory default configuration … 1-10, 4-12 to delete password protection … 3-4 Index – 1 Index CLI prompt, console displaying … 2-27 configuration … 2-17 checking when troubleshooting … 4-3 DHCP/Bootp … 3-1 IP address … 3-2 IP address, manually … 3-2 manager password … 3-2 restoring factory defaults … 1-10, 4-12 subnet mask … 3-2 Switch Setup screen … 3-2 connecting the switch to a power source … 2-16 connecting the switch to an EPS … 2-24–2-25 connecting the switch to an RPS/EPS … 2-22–2-24 connector specifications … A-3 console checking messages during troubleshooting … 4-10 displaying the CLI prompt … 2-27 features … 2-26 how to connect in-band … 2-26 how to connect out-of-band … 2-26 serial cable connection … 2-27 Switch Setup screen … 3-2 Telnet access … 3-5 terminal configuration … 2-26 console port definition … 1-11 location on switch … 1-4 cross-over cable pin-out … B-7 D deleting passwords … 1-10 description back of switch … 1-11 front of switch … 1-4 LEDs … 1-5 switch … 1-1 desktop switch sample topology … 2-28, 2-32 DHCP automatic switch configuration … 3-1 for in-band access … 2-26 2 – Index diagnostic tests … 4-10 checking the console messages … 4-10 checking the LEDs … 4-10 end-to-end connectivity … 4-11 testing the switch only … 4-10 testing twisted-pair cabling … 4-11 downloading new switch software … 4-13 E electrical specifications, switch … A-1 EMC regulatory statements … C-8 environmental specifications BTU ratings … A-2 environmental specifications, switch … A-2 EPS … 2-19 connecting to a switch … 2-24–2-25 EPS input port … 1-12 F factory default configuration, restoring … 1-10, 4-12 Fan Status LED … 1-6 Fault LED … 1-5 behavior during self test … 2-8 behaviors … 1-5 flashing definition … 1-7–1-8 location on switch … 1-4 showing error conditions … 4-4 features console … 2-26 switch … 1-12 fiber-optic cables … B-2 1000Base-BX … B-2 1000Base-LH … B-2 1000Base-T … B-2 flashing LEDs error indications … 4-4 front of switch … 1-4 10/100Base-TX ports … 1-4 Clear button … 1-10 description … 1-4 LEDs … 1-5 network ports … 1-5 Reset button … 1-10 full-duplex fixed configuration effects on network connections … 4-1 M horizontal surface mounting switch on … 2-15 HP Auto-MDIX feature description … B-4 MDI-X to MDI network cable … B-6, B-8 MDI-X to MDI-X network cable … B-7 mini-GBICs full-duplex operation half-duplex operation … 2-17 slot, location on switch … 1-4 mounting the switch in a rack or cabinet … 2-9 precautions … 2-3 on a horizontal surface … 2-15 on a wall … 2-14 precautions … 2-14 Multiple-Display Port LEDs … 1-9 I in-band … 3-1 in-band console access types of … 2-26 included parts … 2-1 installation connecting the switch to a power source … 2-16 horizontal surface mounting … 2-15 location considerations … 2-6 network cable requirements … 2-6 precautions … 2-3 rack or cabinet mounting … 2-9 site preparation … 2-6 wall mounting … 2-14 IP address configuring … 3-2 IP telephones … 2-32 L LEDs behavior during self test … 2-8 checking during troubleshooting … 4-10 descriptions of … 1-5 error indications … 4-4 Fan Status … 1-6 Fault … 1-5 behavior during self test … 2-8 showing error conditions … 4-4 flashing definition … 1-7–1-8 location on switch … 1-4 on switch … 1-5 port description … 1-8 Power … 1-5 behavior during self test … 2-8 Self Test … 1-7 behavior during self test … 2-8 link test … 4-11 location for the switch, considerations … 2-6 Index H N network cables fiber-optic, specifications … B-2 HP Auto-MDIX feature … B-4 required types … 2-6 twisted-pair connector pin-outs … B-4 twisted-pair, wiring rules … B-5 network devices connecting to the switch … 2-16 network ports connecting to … 2-16 location on switch … 1-5 standards compliance … A-3 types of … 1-5 non-standard network cables, effects … 4-2 O out-of-band console access … 3-5 P parts, included with the switch … 2-1 password configuring … 3-2 passwords deleting with the Clear button … 3-4 if you lose the password … 3-4 passwords, deleting … 1-10 physical specifications, switch … A-1 Ping test … 4-11 Index – 3 Index pin-outs twisted-pair cables … B-4 PoE LED patterns … 4-8 PoE troubleshooting … 4-8 port configuration checking when troubleshooting … 4-3 port LEDs description … 1-8 normal operation … 2-8 ports 10/100Base-TX, location on switch … 1-4 connecting to … 2-16 console … 2-26 HP Auto-MDIX feature … B-4 network connections … 2-16 power connector … 1-12 Power LED … 1-5 behavior during self test … 2-8 behaviors … 1-5 location on switch … 1-4 power source connecting the switch to … 2-16 Power-over-Ethernet PoE … 2-19 PoE power … 1-2 precautions mounting the switch … 2-3 power requirements … 2-3 preparing the installation site … 2-6 Proactive Network tools diagnostics with … 4-9 ProCurve 600 Redundant and External Power Supply … 1-3 ProCurve 610 External Power Supply … 1-3 R rack mounting precautions … 2-3 mounting the switch in … 2-9 recycle statements … D-1 Redundant and External Power Supply … 1-3 RPS/EPS … 2-19 Redundant Power Supply … 2-19 regulatory statements … C-8 4 – Index Reset button description … 1-10 location on switch … 1-4, 1-10 restoring factory default configuration … 4-12 resetting the switch factory default reset … 4-12 location of Reset button … 1-10 troubleshooting procedure … 4-10 RPS/EPS … 2-19 cables … 2-20 connecting to a switch … 2-22–2-24 operation … 2-20 S safety and regulatory statements … C-1 safety specifications … A-4 segment switch sample topology … 2-29, 2-33 self test Fault LED behavior … 2-8 LED behavior during … 2-8 Power LED behavior … 2-8 Self Test LED … 1-7 behavior during factory default reset … 4-12 behavior during self test … 2-8 serial cable for direct console connection … 2-27 SFP ports … 1-2 slots for mini-GBICs location on switch … 1-4 specifications acoustic … A-3 cable length … A-3 cabling … B-1 connectors … A-3 distance … B-2 electrical … A-1 environmental … A-2 physical … A-1 safety … A-4 straight-through cable pin-out … B-6, B-8 subnet mask configuring … 3-2 T technology distance specifications … B-2 Telnet access to the console … 3-5 terminal configuration … 2-26 testing checking the console messages … 4-10 checking the LEDs … 4-10 diagnostic tests … 4-10 end-to-end communications … 4-11 link test … 4-11 Ping test … 4-11 switch operation … 4-10 switch-to-device communications … 4-11 twisted-pair cabling … 4-11 tips for troubleshooting … 4-1 topologies effects of improper topology … 4-2 samples of … 2-28, 2-32 troubleshooting … 4-1 basic tips … 4-1 checking port configuration … 4-3 checking the console messages … 4-10 checking the LEDs … 4-10 common network problems … 4-1 connecting to fixed full-duplex devices … 4-1 diagnostic tests … 4-10 effects of improper topology … 4-2 effects of non-standard cables … 4-2 link test … 4-11 Ping test … 4-11 Proactive Network tools … 4-9 restoring factory default configuration … 4-12 testing connections to other devices … 4-11 testing end-to-end communications … 4-11 testing the switch … 4-10 testing the twisted-pair cables … 4-11 twisted-pair cable cross-over cable pin-out … B-7 pin-outs … B-4, B-6, B-8 straight-through cable pin-out … B-6, B-8 switch-to-computer connection … B-6, B-8 switch-to-switch or hub connection … B-7 testing … 4-11 twisted-pair ports HP Auto-MDIX feature … B-4 V VT-100 terminal serial cable connection for … 2-27 W wall mounting switch on … 2-14 wiring rules for twisted-pair cables … B-5 Index – 5 Index switch connecting to a power source … 2-16 description … 1-1 downloading new software … 4-13 electrical specifications … A-1 environmental specifications … A-2 features … 1-12 front panel description … 1-4 included parts … 2-1 LED descriptions … 1-5 mounting in a rack or cabinet … 2-9 mounting on a wall … 2-14 mounting on horizontal surface … 2-15 physical specifications … A-1 switch operation verifying after installation … 2-6 Switch Setup screen … 3-2 configuring a subnet mask … 3-2 configuring an IP address … 3-2 field descriptions … 3-3 switch specifications … A-1 ProCurve 5400zl Switches Installation and Getting Startd Guide Technology for better business outcomes To learn more, visit www.hp.com/go/procurve/ © Copyright 2007 - 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP will not be liable for technical or editorial errors or omissions contained herein. July 2009 Manual Part Number 5991-8573 *5991-8573*
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res Page Mode : UseOutlines XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : FrameMaker 8.0 Modify Date : 2009:06:29 11:16:23-07:00 Create Date : 2009:06:29 08:16:18Z Metadata Date : 2009:06:29 11:16:23-07:00 Format : application/pdf Title : 2610 Install Guide Creator : HP ProCurve Networking Document ID : uuid:13a2170f-8fbf-437c-bcdd-d3478f40ccef Instance ID : uuid:21bdf503-c3bd-4a41-a5c6-34793182b17f Has XFA : No Page Count : 112 Author : HP ProCurve NetworkingEXIF Metadata provided by EXIF.tools