Huawei Technologies EGW1530 Enterprise Gateway User Manual
Huawei Technologies Co.,Ltd Enterprise Gateway
Contents
User Manual.pdf
eSpace EGW1530B Enterp prise Gateway V100R001C01 Quick Start eSpace EGW1530B 企业网 网关 V100R001C01 快速入门 Issue:03 Part Number:31505386 Date:2012-09-12 文档版本:03 文档版本:31505386 发布日期:2012-09-12 HUAWEI TECHNOLOGIES CO., LTD. Welcome Welcome to eSpace EGW1530B Enterprise e Gateway (EGW1530B). This document describes how to install and configure the EGW1530B. For more information, please refer to the eSpace EGW1530B Enterprise Gateway Product Documentation provided in the CD-ROM delivered with the device. Usage Notice Keep the power plugs clean and dry to avoid electric shock and other potential risks. w this product. Use the power supply adapter provided with Keep your hands dry when plugging in out the device cable. Power off ff the th device, d i remove allll connecttted d cables, bl and d contact t t authorized th i d maintenance personnel if smokes, noisess, or odors come from the device. Packing List EGW1530B Document CD-ROM phone lines (3) Power supply adapter Analog Warranty Card Quick Start Network cable (1) PoE Power(optional) Device Appearance Rear View Side View RESET: Press the button for short time (≤ 6s) to estart. Press the button for long time (> 6s) to re re estore factory settings. WLAN: Press the button for short time (≤ 6s) to en nable or disable WLAN. Press the button for long tim me (> 6s) to activate WPS. Installation 1 Preparing Installation Tools Phillips screwdriver Claw hammer Hammer drill Level ruler 2 Installing the EGW1530B Install the EGW1530B on a horizontal surfacce or on a wall. z Installing I t lli the th EGW1530B on a horizontal h i t l surface iis easy. Y You only l need d tto place it on the surface and leave 10 cm space arround for heat dissipation. z To install the EGW1530B on a wall, fix th he swell fixtures (M4) and ensure that 5 mm of the swell fixtures is exposed for mountting the EGW1530B. 3 Connecting Cables After cables are connected, press the power button to power on the EGW1530B. View a check the EGW1530B working status. the POWER indicators (on the front panel) and If the POWER indicator is steady, the EGW1530B is working properly. Configuring the EGW1530B Scenario Description This chapter describes the Internet access and a voice functions of the EGW1530B. The EGW1530B supports Internet access throug gh ADSL or WAN. In WAN mode, three methods are available: account and passwo ord, static IP, and DHCP. For the specific Internet access mode and data, contact you ur local network carrier. The audio function of the EGW1530B is use ed in one of the following scenarios: independent IP PBX, IMS/NGN access gate eway, and local gateway in a branch in the UC solution. The following describes the con nfiguration methods in these scenarios. For details about scenario description and config guration cases, see the documentation CDROM delivered with devices. Starting Configuration ——Netwo orking on a Planning Network Access Informatio Item Parameter Account Planning Description PPPoE user name PPPoE password WAN IP address WAN Static IP WAN subnet mask WAN gateway IP address Primary DNS server DHCP PVC Identifier (VPI) ADSL ADSL and WAN are available. The WAN modes include the account, static IP, and DHCP submodes. To obtain the network access mode and data, contact the local network carrier. PVC Identifier (VCI) PPPoE user name PPPoE password SSID Indicates the ID of the EGW1530B. The ID is displayed on a Wi-Fi terminal after the terminal finds the EGW1530B. The default ID is eSpace EGW_****. **** is the last four digits in the WLAN MAC address address. Wireless access password The password is a string consisting of 8 to 63 ASCII characters or 64 hexadecimal digits. The default password is the WLAN MAC address of the EGW1530B. Wireless function b Logging In to the Web Managementt System Connect a PC to a LAN port on the EGW W1530B using a network cable. Log in to the EGW1530B using Internet Explorer 6.0 or a later version on the PC. The default URL is https://192.168.1.1. word (default: Admin@123) and click Log In. Enter the user name (admin) and passw c Starting Configuration Choose Quick Setup from the navigation n tree on the web management system. Choose a country and click Next. Select a network connection mode accorrding to step a , set relevant parameters, and click Next. Verify parameter settings. 4 Click Save And Continue and configure the audio function. If the audio function does not need to be configured, click Sav ve And Exit to exit the configuration wizard. Starting Configuration —— Indep pendent IP PBX a Planning Users' Internal Numbers Analog phones, fax machines, IP phones, an nd IADs can be connected to the EGW1530B. You are advised to connect faxx machines to the EGW1530B through the PHONE port. When the EGW1530B functions as an indep pendent IP PBX, users can dial the outgoing prefix plus the called number to ma ake an outgoing call, and the call is routed through the FXO ports or BRI ports. oing prefix is deleted according to the The default outgoing prefix is 888. The outgo called number change rule in outgoing calls. An internal number is a string of 1 to 30 digitts. ts Phone Type User Type Internal Number Example Fax machine or analog phone POTS user 6001 IP phone SIP user 6002 Analog phone 1 (connected to the EGW1530B through the IAD) SIP user 6003 Analog phone 2 (connected to the EGW1530B through the IAD) SIP user 6004 ... ... ... b Starting Configuration On the SIP S Server page, disable the UC C mode and click Next. 1 O 2 Click Next to access the analog phone coonfiguration page. Registration groups do not need to be configured when the EGW W1530B functions as the IP PBX. 3 Based on the data plan in step a , configure internal numbers of POTS users, al numbers blank, and click Next. leave the registration groups and externa 4 Click Add in the right part of the IP Phone page. Based on the data plan in step a , configure internal numbers of SIP users, leave the registration groups and external numbers blank, and click Next. 5 Click Finish to finish EGW1530B configuration. 6 Configure the IAD. The following describees how to configure IAD208E(M). 1. Open Internet Explorer and enter the IAD IP address (default: 192.168.100.1) in the address box. 2 Enter 2. E t the th user name (default: (d f lt root) t) an nd d password d (d (default: f lt admin) d i ) and d click li k Log In to access the web management page. 3. Choose Basic Configuration > Netw work Parameter and select the static IP mode. Set the IAD IP address to 192.168.1.x (default IP address of the LAN port on the EGW1530B: 192.168.1.1), set the subnet mask to 255.255.255.0, to 192.168.1.1. and set the IP address of the default gateway 4. Choose SIP Service Configuration > SIP Server and set the IP address of the SIP server to the IP address of the LA AN port on the EGW1530B (for example, 192.168.1.1). 5. Choose SIP Service Configuration > FXS User and set User ID (indicating user numbers) based on the data plan n in step a . 7 Configure an IP phone. The following desscribes how to configure an eSpace 78xx IP phone. For details about other models, se ee the appropriate administrator guide. 1. Enter the IP address of the IP phone in i the address box of Internet Explorer(You can click OK on the IP phone to view the IP address of the IP phone). default values: admin) of the administrator 2. Enter the user name and password (d and click Log In to access the web management page. 3. Click the Account tab. Set Register Name to the user number of the IP phone based on the data plan in step a . Se et SIP Server to 192.168.1.1 (default IP address of the LAN port on the EGW1 1530B). 4. Click Submit to finish IP phone config guration. You can choose Voice > Phone Alloc cation > IP Phone in the web management system of the EGW1530B to view the e registration status of the IP phone. Verifying Configuration in this 8 Verify the configuration according to the chapter document. Starting Configuration —— IMS/N NGN Access Gateway a Planning SIP Server Data Item Description Type of the SIP server address The address can be an IP address and or a domain name. Obtain the type from the network carrier. SIP server address me of the SIP server. Obtain the address from the IP address or domain nam network carrier. For examp ple, the value can be 191.1.1.1 or m04.huawei.com. SIP ser server er ttype pe The options are NGN and IMS. IMS Obtain the ttype pe from the net network ork carrier carrier. Heartbeat detection interval B to send heartbeat messages to the active SIP Interval for the EGW1530B server, in seconds. The va alue ranges from 10 to 900. The default value 60 is recommended. Registration interval Interval for the registration n group to send registration messages for users in this group to the SIP serve er, in seconds. The value ranges from 0 to o 14400. The default value 360 is recommended. b Planning the Registration Group Assume that the EGW1530B connects to the e IMS, and the registration group type is user-by-user registration. To obtain the registration group type, trunk re egistration user ID, trunk registration user name, IMS domain name, external numbers,, Authentication and Password, contact the network carrier. When the SIP server type yp is NGN,, leave the IMS domain name blank. Registration Group ID Registration Group Type Trunk Registratio on User ID Trunk Registration User Name IMS Domain Name User-by-user registration +8657187654321 +8657187654321@abc. def.com abc.def.com User-by-user registration +8657187654322 +8657187654322@abc. def.com abc.def.com User-by-user registration +8657187654323 +8657187654323@abc. def.com abc.def.com ... ... ... ... ... c Planning User Numbers Analog phones, fax machines, IP phones, an nd IADs can be connected to the EGW1530B. You are advised to connect faxx machines to the EGW1530B through the PHONE port. NOTE z The ID of the registration group corresponnding to an external number of a user must be the same as that of the the trunk registration user u ID. If the trunk registration user ID starts with +, you need to change + to 00 when youu configure an external number. z Internal numbers can be customized. User User Type IIntern t nall Number N b Exam mple R i t ti Registration Group ID E t External l Number N b Example Fax machine or analog phone POTS user 6001 008657187654321 IP phone SIP user 6002 008657187654322 Analog phone 1 (connected to the EGW1530B through the IAD) SIP user 6003 008657187654323 Analog phone 2 (connected to the EGW1530B through the IAD) SIP user 6004 008657187654324 ... ... ... ... ... d Starting Configuration page disable the UC mode and click Add. Add Configure the SIP 1 On the SIP Server page, server based on the data plan in step a and click Next. 2 Configure the registration group based onn the data plan in step b and click Next. numbers based on the data plan 3 Configure the POTS user's internal and external in step c and click Next. 4 Click Add in the right part of the IP Phone page. Configure the SIP users' internal and external numbers based on the data plan in step c and click Next. 5 Click Finish to finish EGW1530B configuration. 6 Configure the IAD. The following describees how to configure IAD208E(M). 1. Open Internet Explorer and enter the IAD IP address (default: 192.168.100.1) in the address box. nd password (default: admin) and click 2. Enter the user name (default: root) an Log In to access the web management page. 3. Choose Basic Configuration > Netw work Parameter and select the static IP mode Set the IAD IP address to 192. mode. 192 168.1.x 168 1 x (default IP address of the LAN port on the EGW1530B: 192.168.1.1),, set the subnet mask to 255.255.255.0, and set the IP address of the default gateway to 192.168.1.1. 4. Choose SIP Service Configuration > SIP Server and set the IP address of the SIP server to the IP address of the LA AN port on the EGW1530B (for example, 192.168.1.1). 5. Choose SIP Service Configuration > FXS User and set User ID (indicating user numbers) based on the data plan n in step c . 7 Configure an IP phone. The following desscribes how to configure an eSpace 78xx IP phone. 1. Enter the IP address of the IP phone in i the address box of Internet Explorer (You can click OK on the IP phone to view the IP address of the IP phone). 2. Enter the user name and password (d default values: admin) of the administrator and click Log In to access the web management page. 3. Click the Account tab. Set Register Name to the user number of the IP phone based on the data plan in step c . Se et SIP Server to 192.168.1.1 (default IP address of the LAN port on the EGW1 1530B). 4. Click Submit to finish IP phone config guration. You can choose Voice > Phone Alloc cation > IP Phone in the web management system of the EGW1530 0B to view the registration status of the IP phone. Verifying Configuration in this 8 Verify the configuration according to the chapter document. Starting Configuration —— Local Gateway in a Branch in the UC Solution a Planning Server Information When the EGW1530B functions as the local gateway in a branch in the UC solution, the SIP server on the central node at the he eadquarters allocates all user numbers and synchronizes them to the EGW1530B. You do not need to configure user numbers on the EGW1530B. Before configuration, collect user quantity in n the branch and apply for number allocation to the enterprise IT administrator. 0B is 888. The outgoing prefix is deleted The default outgoing prefix of the EGW1530 according to the called number change rule in outgoing calls. Server Type Data synchronization server Planned Item Remarks IP address Contact the enterprise IT administrator to obtain the IP address of the data synchronization server. Port number IT administrator to obtain the port Contact the enterprise number of the e data synchronization server. If the port number fails to t be obtained, use the default value 8098. 30B compares its data synchronization key with The EGW153 that of the da ata synchronization server. If the keys are the same, the data synchronization server synchronizes data to the EGW1530 Key for data 0B; otherwise, the EGW1530B rejects the data synchronization synchronization. The key is a string of 1 to 22 characters including digits, letters, or special characters. You can negotiate with h the enterprise IT administrator about the key format. SIP server address The address can be an IP address and or a domain name. ddress from the enterprise IT administrator. Obtain the ad a IMS or NGN. Obtain the type from the The options are IT administrator. SIP server type enterprise When the SIP P server is eSpace U1960, select NGN. When the SIP P server is eSpace U2900, select IMS. SIP server Heartbeat detection interval Interval for the EGW1530B to send heartbeat messages to the active and d standby SIP servers, in seconds. The value ranges from 30 3 to 150. The default value 90 is recommended. Registration interval Interval for the registration group to send registration messages forr users in this group to the SIP server, in seconds. The e value ranges from 0 to 14400. The default value 360 is recommended. b Starting Configuration Configure the data synchronization 1 On the SIP server page, enable the UC mode. server based on the data plan in step a . 2 Click Add. Configure the SIP server baseed on the data plan in step a and click Next. 3 Click Finish. You can choose Voice > Phone Allocatiion in the web management system of the EGW1530B to view the synchronized use er number. NOTE When configuring the IP phone, set SIP server 1, SIP server 2, and SIP server 3 to the active SIP server in the central node, standby SIP server in the central nod de, and IP address of the LAN port on the EGW1530B. Verifying Configuration in this 4 Verify the configuration according to the chapter document. Verifying Configuration a Verifying Network Access You can visit a website (for example, http://e enterprise.huawei.com) and verify the network function. If the access is successful,, the network function is correctly configured. b Verifying the Audio Function z Independent IP PBX • Intra-office users dial each other's interrnal numbers using phones that have numbers configured. • An intra-office user under the EGW1530B to dial the outgoing prefix (888) and the number (for example, mobile phone number) of an outer-office user. hat the PSTN network carrier assigns to the • An outer-office user dials the number th FXO port of the EGW1530B. After hearring the announcement played by the switchboard, the outer-office user dials the extension number (that is, the internal number). z IMS/NGN access gateway • Intra-office users dial each other's interrnal numbers using phones that have numbers configured. • Calls are made between an analog pho one or IP phone under the EGW1530B and a network-side number (for example, a mobile phone number). z Local gateway in a branch in the UC solu ution • Intra-office users dial each other's interrnal numbers using phones that have numbers configured. • An intra-office user under the EGW1530B to dial the outgoing prefix (888) and the number (for example, mobile phone number) of an outer-office user. • An outer-office user dials the number th hat the PSTN network carrier assigns to the FXO port of the EGW1530B. After hearring the announcement played by the switchboard, the outer-office user dials the extension number (that is, the internal number). alls are connected successfully. If a call In the preceding scenarios, verify that the ca fails, check the configuration and cable conn nection. Seeking Technical Support and Obtaining Documentation Technical support Contact the device supplier to obtain tech hnical support. Documentation Obtain documentation from the CD-ROM delivered with the device or choose SUPPORT > Products > UC&C > UC > UC in http://enterprise.huawei.com to obtain documentation. Declaration on Hazardous Substa ances in Electronic Information Products Parts Hazardous Substtances Pb Hg Cd Cr6+ PBB PBDE Mechanical part × ○ ○ ○ ○ ○ Board/circuit module × ○ ○ ○ ○ ○ Signal cable × ○ ○ ○ ○ ○ Cable connector × ○ ○ ○ ○ ○ Power adapter × ○ ○ ○ ○ ○ Auxiliary equipment × ○ ○ ○ ○ ○ ○:Indicates that the concentration of the hazardous substance contained in all the homogeneous materials t i l off thi this partt iis b below th the e limit li it requirement t off th the SJ/T 11363−2006 11363 2006 standard. ×: Indicates that the concentration of the hazardous substance contained in all the e limit requirement. homogeneous materials of this part is above the NOTE 1. Mechanical part such as shell: The steel, aluminum m or copper materials contain lead. 2. Board and circuit module: z The PCB pad contains lead. z Ceramic capacitor or feedthrough capacitor or mica capacitor on the board: The ceramic chip contains lead. z The resistor inside the clock oscillator is immu une from lead. z The high temperature type solder, used for the connector inside the transformer, contains more than 85% lead. z The luminescence glass of chip inductor contaiins lead. z The high temperature type solder used for the transistor chip contains lead. z The glass of resistance layer and protection lay yer is immune from lead. z The pin and solder of the components such as the t IC and power unit contain lead. 3. Signal cables: The alloy materials such as the steell, aluminum, and copper materials contain lead. 4. Cable connector: For most connectors, the metal sh hell, terminal and pin contain lead. 5. Power adapter: The interior contains lead. 6.The circuit board of the auxiliary equipment contain ns lead. Same as point one and point two. 10
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : 3.1-701 Modify Date : 2013:01:14 11:29:41+08:00 Create Date : 2013:01:14 11:29:27+08:00 Metadata Date : 2013:01:14 11:29:41+08:00 Creator Tool : PScript5.dll Version 5.2 Format : application/pdf Title : Microsoft PowerPoint - eSpace EGW1530B 快速入门.ppt [兼容模式] Creator : z00197330 Document ID : uuid:f1bea733-70f5-4ad1-b7bb-80fdb0dc1adf Instance ID : uuid:e811ce51-34b8-420e-b633-842688b33fe7 Producer : Acrobat Distiller 7.0 (Windows) Page Count : 11 Author : z00197330EXIF Metadata provided by EXIF.tools