Hulu Devices HULUDEV0001 Smartphone Auscultatory Blood Pressure Kit User Manual
Shanghai Hulu Devices Co., Ltd. Smartphone Auscultatory Blood Pressure Kit
User Manual

Accutension
SmartphoneAidedAscultatoryBloodPressureKit
cuff
stethoscope
head
1.Batteryindicator
2.Setconnection
3.Currentuser
DearCustomer,
ThankyouforchoosingAccutension.Beforeyouusetheproduct,
pleasereadthemanualcarefullyandfollowtheinstructions.This
kitisnotanautomaticbloodpressuremonitor,sosomepractice
maybeneededtomakeitworkproperly.Pleasecontactusifyou
encounter any problem
phone
artery
hand
pump
5.SystolicBP
markingline
6
Diastolic BP
4.Cuffpressure
display
encounter
any
problem
.
1. PackingList
Item Quantity
Cuff (22cm
‐
32cm)
1
pressure
sensor
module
6
.
Diastolic
BP
markingline
Cuff
(22cm
32cm)
1
Cuff(32cm‐42cm) 1
PressureSensorModule 1
Handpumpwithquickrelease 1
slow
deflation
vent
quick
l
7.Cuffdeflation
speed
Stethoscopewithmicrophone 1
MicroUSB chargingcable 1
Headphone plugconverter 2
Slow
deflation vent
3
Figure1.TheKitSetupAndOperation
2showsthemeasurementuserinterface.No.1isthepressure
dl b d d h h h
re
l
ease
valve
8.BPreadingpicker
2. Setupthekit
Slow
deflation
vent
3
Short rubbertube 2
sensormo
d
u
l
e
b
atteryin
d
icatoran
d
its
h
owsupw
h
ent
h
e
connectionisformed.No.2istheconnectionbutton.Before
measurement,youneedtotouchthisbuttontosetconnectionafter
thepressuresensormoduleispoweredon.No.3isthecurrentuser
icon.DefaultisGuest.Youcancreatenewusersin“more”tab.If
therearemultipleusers,youcantouchthisbuttontoswitchthe
Figure2.MeasureUserInterface
isastandard3.5mmheadphoneplug,pleaseplugitintoyour
phonejack.Ifyouwanttohearthesoundsinrealtime,youcan
hhdh l h l l h
Figure1showshowthepartsareconnectedtogetherandhow
thekitisoperated.Thecufftubeisconnectedtothepressure
sensormodule,thentotheslowdeflationventandthentothe
handpumpwithquickreleasevalve.Youcanusetheshortrubber
tubeweprovidedtomaketheconnection.Threeslowdeflation
vents with different deflation rates are provided You need to
user.No.4isthelocationtoshowcuffpressureduringcuffinflation
anddeflation.No.5and6arethesystolicanddiastolicBPmarking
linesrespectively.YoucanmoveNo.5tothefirstsoundofblood
flowpulseandNo.6tothelast.Thesetwolinescanbemovedby
scrollingNo.8.WhenyouscrollingupanddownNo.8,thenumbers
chan
g
ewithBPmarkin
g
linelocations.No.7showsthecuffdeflation
uset
h
e
h
ea
d
p
h
onep
l
ugconverter.Int
h
iscase,p
l
easep
l
ugt
h
e
stethoscopeandyourheadphoneintotheconverterandthen
plugtheconverterintothephone.Youneedtochoosethe
converterwiththerightcolordependingonyouriDevice as
showninthetablebelow.
Sitbl f
iD i
iChi
vents
with
different
deflation
rates
are
provided
.
You
need
to
choosetherightoneafteryoulearnedyourroughbloodpressure
valueandtherightcuffsizewiththeaidofAppthatwillbe
introducedlater.Youneedtochoosetherightcuffsize.Thecuff
hasanindexandpleasemakesureitiswithintheOKrangewhen
youwearit.
g g
speedafterthemeasurement.Cuffdeflationspeedisimportantfor
Auscultatory method.Pleaseselectrightslowdeflationventtomake
thespeedwithin2‐4mmHg/s.
4. Doameasurement
StarttheApp.
SetBluetoothconnection. Touchtheconnecticon(No.2of
Fi
g
ure2
)
andinthe
p
o
p
u
p
windowchooseAccutension.The
S
u
it
a
bl
e
f
or
iD
ev
i
ce
i
n
Chi
na
Suitable foriDevice outofChina
3. Get familiarwiththeApp
Search“Accutension”inAppleAppStoretoinstalltheapp.Figure
Poweronmodule. Pushthebuttonforawhilewillturnonthe
pressuresensormodule.Whenitison,thebluelightwillblink.
Plugthestethoscopeintoyourphone.Oneendofthestethoscope
g ) ppp
Bluetoothconnectionbetweenthepressuresensormoduleand
thephonewillbeset.Thebluelightofthepressuresensor
modulewillstopblinking.

pleasedoyourbesttoavoidnoise.Forexample,findaquiet
placetodothemeasurement.Askothersnottotalkduring
measurement.Keepthetubeofthestethoscopeclearfrom
thecufftubetoavoidunnecessarynoise.Don’ttouchthe
Choosetheuser. FollowinstructionsinSection3tochangea
user.
Wearthecuff. Thebottomcuffedgeneedstobe1inchabove
theantecubitalfossa.TheCuffcan’tbetoolooseortwotight.It
i h i
fi i
hff
①②
tubeofthestethoscopeduringmeasurement.
b. Pleasedonotusewhenyouchargeyourphonebecauseof
heavyelectricalnoise.
c. Ifyouhavequestionsonthesoundsorthenumber,youcan
sendthesoundstoyourdoctorormedicalprofessionals
throu
g
hemail.Youdoctorcano
p
enthemeasurementdata
i
sOKto
h
avesomespacetoput
i
ntotwo
fi
ngert
i
ps.T
h
ecu
ff
INDEXneedstobewithintheOKrangeasprintedinthecuff,
otherwisetryanotherone.
Startmeasurement.Quicklypumpthecufftothepressure
30mmHghigherthantheestimatedbloodpressurevalue.For
example,ifyoursystolicbloodpressureis120mmHg,youneed
(a)
①② ③ ④
g p
inhis/herphonetofindtheBPreadingsforyou.
d. Followallthenormalbloodpressuremeasurement
requirement.Forexample,takearestbeforemeasurement,
beseatedonachairwithbacksupport,puttwofeetonthe
floor,keepthecuffonthesameleveloftheheart,etc.
e
The pressure sensor module can be cross
‐
calibrated with
topumpthecufftoatleast150mmHg.Thenstoppumping,the
cuffwillstartselfdeflation.Youcanseethesoundsignalsonthe
phonescreen.TheKorotkoff soundsignalwillappearwhenthe
systolicbloodpressureisreached.Thenthesoundsignalwill
continueonthescreenuntilthediastolicbloodpressureis
reached.Then
y
ouneedto
p
ushthe
q
uickreleasebuttononthe
(b)
①
②
e
.
The
pressure
sensor
module
can
be
cross
‐
calibrated
with
mostoftheupperarmautomaticbloodpressuremonitors
ortraditionalbloodpressurekit,soifyoufindanyabnormal
ofthepressurenumber,youcandothisbyfindinganother
bloodpressuremonitor.
f. YoucanusethemicroUSBcabletochargethepressure
sensor mod le The red light is on dringcharge The green
y
p q
manualpumptoquicklydeflatethecuff.Pleasemakesurethe
cuffairisfullyreleasedwhenyoureleasethebutton.Nowthe
phoneshoulddisplaythebloodpressurevalue.Pleasebenoted
thatthebloodpressurevalueisnotthefinalvaluebecausethisis
notanautomaticbloodpressurekit.Youmightneedtoplayback
the sounds to double confirm
(c)
①
②
sensor
mod
u
le
.
The
red
light
is
on
d
u
ring
charge
.
The
green
lightisonwhenthechargeisfull.
g. YoucanuseAccutension Stetho Apptocheckthealgorithm
accuracyofanautomaticBPM.ThatApprequiresaQRcode
toregister.Hereisthecodetoscan.Inthefuture,
Accutension Appmayalsoneedthiscode.SoPleasekeep
the
sounds
to
double
confirm
.
Choosetherightslowdeflationvent. Therearethreeslow
deflationventsingrey,whiteandbluerespectively.Thegreyone
hasthefastestdeflationwhiletheblueonehastheslowest
deflation.Thedeflationspeedwillbeshowedaftereach
measurement.Thebestdeflationspeedis2‐ 4mmHg/s,soifitis
higher than that please select aslower deflation valve The ideal
(d)
①②
thismanual.
higher
than
that
,
please
select
a
slower
deflation
valve
.
The
ideal
rangeofdeflationspeedis2mmHg‐4mmHgtobalanceaccuracy
andcomfort.
Playbackthesounds. TouchPlaybackintheApptoplaybackthe
sounds.Youneedtouseheadphonetolistenclearlybecausethe
iphone speakerisnotgoodatplayinglowfrequency(bass)
d
Figure3VariousSoundsStrengthCurves
①issystolicBPand④isdiastolicBP.Iftheyarethelatter,③is
systolicBPand④isdiastolicBP.
(c) shows that the
auscultatory
sounds do not disappear After
②
soun
d
s.
Adjustthereadingifnecessary. Youcanscrolltheblood
pressurenumberpickertoadjustthebloodpressuremarking
linelocation.
Interpretthesoundscurve. Figure3showsvarioussounds
strengthcurves.Pleasenotenoisesuchasfrictioncaninducea
(c)
shows
that
the
auscultatory
sounds
do
not
disappear
.
After
②
,
thesoundsbecomeweakandthesoundsstrengthkeepsalmost
unchanged.Thisalsohappenstosomepeople.Inthiscase,②is
diastolicBP.
(d)showsirregularheartbeat.ForexampleAfib patientshavethis
kindofsoundsstrengthcurve.Forthiscase,youneedtoplayback
and listen carefully to find out the first and last sounds of blood flow
peakinthesoundscurve,sothefeaturesofbloodflowsounds
canhelpyourecognizethenoisesometimes.
(a)isthemostcommoncurve.Itshowsregularheartbeat,there
isclearfirstsoundandlastsoundofbloodflowpulse.①is
systolicBPand②isdiastolicBP.
(
b
)
showsthereisa
g
a
p
betweenre
g
ularsoundssi
g
nals.Forthis
and
listen
carefully
to
find
out
the
first
and
last
sounds
of
blood
flow
.
Accutension canhelpyoufindoutthiskindofirregularheartbeat.
Youneedtoconsultyourdoctorwhenyoufindthisphenomenon.It
couldbelinkedtosomediseases.
Turnoffthepressuresensormodule. Pleasedonotforgettoturn
offthepressuresensormoduleafteruse!
() gp g g
case,youneedtolistentoconfirmwhetherthefirstpart①‐②
arethebloodflowpulsesoundsornoise.Iftheyaretheformer,
thegapiscalledauscultatory gapandithappenstosomepeople.
5. Others:
a. Thesoundqualitydeterminesthemeasurementquality.So

FCCStatement
Thisdevicecomplieswithpart15oftheFCCRules.Operation
issubjecttothefollowingtwoconditions:(1)Thisdevicemay
notcauseharmfulinterference,and(2)thisdevicemust
acceptanyinterferencereceived,includinginterferencethat
maycauseundesiredoperation.
AnyChangesormodificationsnotexpresslyapprovedbythe
partyresponsibleforcompliancecouldvoidtheuser's
authority to operate the equipment
authority
to
operate
the
equipment
.
Note: Thisequipmenthasbeentestedandfoundtocomply
withthelimitsforaClassBdigitaldevice,pursuanttopart15
oftheFCCRules.Theselimitsaredesignedtoprovide
reasonableprotectionagainstharmfulinterferenceina
residentialinstallation.Thisequipmentgeneratesusesand
canradiateradiofrequencyenergyand,ifnotinstalledand
usedinaccordancewiththeinstructions,maycauseharmful
interferencetoradiocommunications.However,thereisno
guaranteethatinterferencewillnotoccurinaparticular
installation If this equipment does cause harmful
installation
.
If
this
equipment
does
cause
harmful
interferencetoradioortelevisionreception,whichcanbe
determinedbyturningtheequipmentoffandon,theuseris
encouragedtotrytocorrecttheinterferencebyoneormore
ofthefollowingmeasures:
‐Reorientorrelocatethereceivingantenna.
‐Increasetheseparationbetweentheequipmentand
receiver.
‐Connecttheequipmentintoanoutletonacircuitdifferent
fromthattowhichthereceiverisconnected.
‐Consultthedealeroranexperiencedradio/TVtechnicianfor
help
help
.