Hunter Fan TX73 Hunter Home Light Control System User Manual Manual

Hunter Fan Company Hunter Home Light Control System Manual

Contents

Manual

43073-01  20080827 1Form# 43073-0120080905©2008 Hunter Fan Co.EnglishNITETIME PRONITETIME PRONITETIME PROOwner’s Guide andInstallation ManualWireless TimerModel45043
©2008 Hunter Fan Company2
43073-01  20080827 3Table of ConTenTsDescription................................................................4Features ...................................................................6Features ...................................................................6Limitations / Warnings ..............................................7Program the NITETIME Pro™ ................................9Setup the NITETIME Pro™ ..................................12KeyChain Operation ...............................................18Battery Replacement ..............................................20Troubleshooting ......................................................22Technical Support ...................................................24The Hunter Product Family.....................................25
©2008 Hunter Fan Company4DesCripTionThe NiteTime Pro™ combines the convenience of photocell controlled time operation and remote control on/off functions. The NiteTime Pro™ plugs into a wall outlet and connects to a standard household lamp or small appliance. Eight pre-programmed settings allow for instant, one-time setup. Programs include basic On and Off timed settings triggered by lighting conditions, as well as randomly-timed modes for creating a lived-in appearance while you are away from home.A built-in photocell automatically adjusts the timer to Daylight Savings Time changes so no resetting is required – even after power outages. The convenient Keychain Remote allows temporary override of programming for use of a lamp or small appliance.
43073-01  20080827 5Figure 1: NiteTime Pro™ ComponentsPhotocellProgram DialA/C PlugHouse CodeDialRemote
©2008 Hunter Fan Company6feaTures• Eightpre-programmedOn-Offtimesegmentsallowforinstant, one-time setup.• Built-inphotocellsensesambientroomlightandautomatically triggers On-Off time segments.• Built-inphotocellautomaticallyadjuststimerforDaylightSavings Time changes. • Timerrequiresnoresetting–evenafterpoweroutages.• Timercanbeusedwithincandescent(standardbulb),compactfluorescent(CFL),orhalogen-basedbulblamps.• Timercanbeusedwithsmallappliancesunder500watts or four Amps such as a radio or television.• RFsignalwithupto60FT.openairrange(Range may vary between installations.Refer to Limitations/Warnings for more information.)• 3YearWarrantyfeaTures
43073-01  20080827 7limiTaTions / Warnings• Forindooruseonly• Notrecommendedfordevicesover500wattsorfourAmps• Whenusedonadevicecontrolledbyawallswitch,thewall switch must remain on at all times for the NiteTime Pro™ to function properly.• PowermustremainontothedeviceusingtheNiteTimePro.• ObstructionsbetweenRemoteandReceivermoduleincluding walls and doors will reduce signal range.• Toreducetheriskofelectricalshock,thisequipmenthasapolarizedplug(onebladeiswiderthentheother).This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact qualified personnel to install the porper outlet. Do not alter the plug in anyway.• Notforusewithgrounded3prongeddevices.
©2008 Hunter Fan Company8limiTaTions / Warnings• This device complies with Part 15 of the FCC Rules. Operationissubjecttothefollowingtwoconditions:(1)this device may not cause harmful interference, and (2)thisdevicemustacceptanyinterferencereceived,including interference that may cause undesired operation.
43073-01  20080827 9Choose the Timer SettingBefore plugging the timer into a wall outlet, choose the desired time program using the Program dial. These instructions apply to both lamps and small electronics. Once set, the program never needs resetting for Daylight Savings Time or power outages. If a timed program is not needed, set the Program dial to 1, PowerOn.Torevertbacktoatimedprogram,changetheProgram dial to one of the settings on page 10.program The niTeTime pro™
©2008 Hunter Fan Company101 - Power On. 2–Dusk+2hrturnspowerOnatdusk,turnspoweroff2hours later.3–Dusk+4hrturnspowerOnatdusk,turnspoweroff4hours later.4–Dusk+6hrturnspowerOnatdusk,turnspoweroff6hours later.5–Dusk+8hrturnspowerOnatdusk,turnspoweroff8hours later.6–Dusk+2hrRandomlypowersOn/offfor30minuteswithineachhourafterduskfor2hours.7–Dusk+4hrRandomlypowersOn/offfor30minuteswithineachhourafterduskfor4hours.8–Dusk+6hrRandomlypowersOn/offfor30minuteswithineachhourafterduskfor6hours.program The niTeTime pro™
43073-01  20080827 11Menu of Timer Settings128231Figure 2: NiteTime Pro™ Programs
©2008 Hunter Fan Company12seTup The niTeTime pro™1.Slidethebatterycoveroffthebackoftheremote.2. Pull out the battery from the battery compartment.3.Removetheprotectivefilmfrombetweenthebatteryandbattery compartment. (Refer to Figure 3)
43073-01  20080827 13Re c e i v e R PR o t e c t i v eFi l m Ba t t e R yBa t t e R y  co v e RKe y c h a i nRe m o t eFigure3-KeychainComponents
©2008 Hunter Fan Company14seTup The niTeTime pro™4. Check the house code on the remote, reinstall the battery, and slide the battery cover back on.5. Ensure that the house code switches on both the Remote andReceivermatch.(refertoFigure4)6. Turn power off to your lamp or appliance and unplug it from your wall outlet.
43073-01  20080827 15Figure 4 - House Code123123
©2008 Hunter Fan Company167. Plug your lamp or applaince into the NiteTime Pro™ Receiver.(refertoFigure5)8. Plug your NiteTime Pro™ Receiver into the wall outlet. 9.Turnpowerbackontoyourlamp.seTup The niTeTime pro™
43073-01  20080827 17Lamp or Appliance CordWall outletNiteTimePro  Figure 5 - Installation
©2008 Hunter Fan Company18KEYCHAIN OPERATIONThe Keychain Remote included with the  NiteTime Pro™ lets you control the attached lamp or appliance with the remote.Press the resessed button once to power the lamp or appliance on and the raised button once to power the lamporapplianceoff.(refertoFigure6)The NiteTime Pro™ will automatically revert to it's programming during the next time program sequence.
43073-01  20080827 19LEDONOFFFigure 6 - Remote Operation
©2008 Hunter Fan Company20Battery Replacement1. To replace the battery in the NiteTime ProTM Remote, removethebatterycoverandtakeoutthebattery.(refertoFigure7)2. Place the new battery, positive side up, inside the Remoteandslidethebatterycoverbackon.NOTE:OnlyreplacewithMAXELLCR2032,3Vbatteryor equivalent.
43073-01  20080827 21CR20323V+Figure 7 - Battery Replacement
©2008 Hunter Fan Company22TroubleshooTing1. My NiteTimer ProTM turns itself on / off. YourproductmaybeexperiencingRFinterference.Refer to "Operation" to learn how to change the house code settings.2. I can't operate the NiteTimer ProTM Remote.  Try changing the battery in the remote control. See "Battery Replacement"3.OneofmylampsdoesnotactivatewiththeNiteTimerProTM product.  Ensure the lamp you are trying to activate with the NiteTimerTM isturnedon.Checkyourhousecodesetting to ensure they are set the same.4. I receive erratic behavior from the NiteTimer Pro™ product.It may be necessary to change the house code your product is set to.
43073-01  20080827 231. Slide the battery cover from your Remote Control and remove the battery.2. Change the House code Switch to another house codenumber.(Figure4)3.ReplacethebatteryandslidetheBatteryCoverbackontheRemote.4. Turn off your lamp and unplug from the NiteTimer Pro™ Receiver.5. Unplug the Receiver and change the dial to the same number you set your Remote Control too. (Figure3)6. Plug your lamp into the NiteTimer Pro receiver and the NiteTimer Pro receiver into the wall outlet.
©2008 Hunter Fan Company24TeChniCal supporTIf you have any additional questions or problems with your Hunter Air Purifier, please call:USA:1-888-830-1326Canada: 1-866-268-1936Hours of operation are from 7:00 am to 7:00 pm Monday - Friday and 8:00 am to 5:00 pm on Saturday, Central Time. YoumayalsocontactusovertheInternetat:WWW.HUNTERFAN.COM
43073-01  20080827 25The hunTer proDuCT familyThermostatsBath FansCeiling FansAir PurifiersHumidifiers

Navigation menu