Hunter ICDHP Decoder System User Manual ICD HP Owners Manual

Hunter Industries Inc Decoder System ICD HP Owners Manual

Users Manual

Download: Hunter ICDHP Decoder System User Manual ICD HP Owners Manual
Mirror Download [FCC.gov]Hunter ICDHP Decoder System User Manual ICD HP Owners Manual
Document ID1125414
Application IDrSS3XYQh7QVNWtzArvC0bA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize40.07kB (500894 bits)
Date Submitted2009-06-16 00:00:00
Date Available2009-06-16 00:00:00
Creation Date2009-05-19 16:57:05
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2009-05-21 15:15:27
Document TitleMicrosoft Word - ICD-HP Owners Manual.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: kmanivone

ICD‐HP
Handheld Programmer for
Hunter ICD Decoders
Owner’s Manual and Operating Instructions
Introduction ............................................................................................................................................................................. 3
ICD‐HP Components ................................................................................................................................................................ 5
Installing the Batteries ..................................................................................................................................................... 7
Keypad Functions ............................................................................................................................................................. 8
Cable and Lead Connections ............................................................................................................................................ 9
Connecting to a Decoder ................................................................................................................................................. 9
Operations ............................................................................................................................................................................. 11
Main Menu & Navigation ................................................................................................................................................... 11
ICD‐HP Set‐up................................................................................................................................................................. 12
Decoder Programming Menu ........................................................................................................................................ 13
Decoder Firmware ......................................................................................................................................................... 23
Diagnostics ..................................................................................................................................................................... 25
Troubleshooting ..................................................................................................................................................................... 27
Specifications ......................................................................................................................................................................... 29
FCC Notice .............................................................................................................................................................................. 30
Industry Canada Notice.......................................................................................................................................................... 31
CE & AUSTRALIA NOTICE........................................................................................................................................................ 31
Introduction
The ICD‐HP Handheld Programmer is an innovative setup, programming, and diagnostic tool for Hunter ICD series
decoder products.
This instrument can operate and program ICD decoders via wireless induction, through the base of the decoder, with a
special programming cup. This allows access to installed decoders, without removing waterproof wire connectors.
ICD‐HP can also be used for initial setup of new decoders. The included power leads will power a decoder for
programming purposes, for installation later.
ICD‐HP can be used for diagnostic operation and testing of installed decoders, solenoids, and even sensors.
ICD‐HP can enable new programming options for ICD decoders. It can program any station numbers in any order within a
multi‐station decoder, and can “skip” stations to reserve them for future use.
ICD­HP Components
ICD‐HP is packaged with required accessories.
Item
Part
Description
----
ICD-HP Programmer
205700
Programming Cup
180504
Programming Cable 6’/2m with
connectors
180508
Red and Blue 6’/2m leads
----
Carrying Case
----
4 x AA batteries
The Programming Cable is NOT a standard BNC connector cable,
and cannot be replaced with a standard coaxial BNC cable.
This item is unique to the ICD‐HP programmer.
Do not attempt to use the ICD‐HP programming cable for any
other purpose!
Installing the Batteries
The ICD‐HP programmer operates with 4 x AA batteries. The batteries supplied are not
rechargeable!
To install batteries:
Remove cables and connectors from end of ICD‐HP.
Pry the yellow flexible yellow boot off the ICD‐HP.
Turn the ICD‐HP over, and remove the 2 screws securing the battery compartment cover
with a small screwdriver (either standard or Philips).
Insert 4 fresh AA batteries as shown, observing polarity.
Replace cover with screws and secure.
Replace yellow boot.
Keypad Functions
1.
Power button.
2.
Number buttons, used to enter station numbers and
other numeric data.
3.
Back button. Returns to previous menu.
4.
Plus and Minus (+/‐) buttons. Used to change station
numbers, and also to turn stations On (+) and Off (‐).
5.
Arrow buttons. Used to navigate within screens, move
pointers, or change outputs on multi‐station decoders.
6.
Enter. Used mostly to retry certain functions.
7.
Question/Info. Used to switch pages, in some screens.
Also used to enter ICD‐HP flash mode.
8.
Next button. Used to select a menu item and go to the
next level. Also used to execute certain commands.
Cable and Lead Connections
Red
Lead
Red and Blue Leads: Connect the straight connectors by pushing all the
way into the appropriately colored plugs.
Programming Cable: Connect either end of the supplied cable to the
connector on the ICD‐HP. Align connector slots with female connector on
programmer, push straight in, and turn 90 degrees until the connector
locks into place.
Connect the other end of the Programming Cable to the Programming
Cup in the same way.
Connecting to a Decoder
Blue
Lead
Programming
Cable
The ICD‐HP programmer works with Hunter ICD and later decoders. The
ICD‐HP programming cup communicates with decoders through wireless induction.
The bottom end of the decoder (opposite the end with the wires) is the receiver area for the signals from the
programming cup.
The entire inside of the cup is within the wireless range,
and it is not necessary to press decoders firmly in place, as
long as they are within the cup. The programming cup
does have pockets for the two different sizes of decoder, and these will help hold the cup and decoder together firmly in
field applications.
Bench Mode: If the decoder is uninstalled, and not connected to the two‐wire path:
Install the red and blue wire leads for the ICD‐HP.
Connect the programming cup to the ICD‐HP.
Clip the red and blue leads to the decoder red and blue leads.
Place the decoder in the programming cup.
Field Mode: If the decoder is installed in the two‐wire path, it is
not necessary to disconnect any decoder wiring.
Connect the programming cup to the ICD‐HP with the
programming cable.
Wipe mud and dirt off the decoder to prevent wear on
the programming cup and interference with the signal.
10
Seat the programming cup over the decoder. The bottom of the decoder (the end with no wires) should be
within the programming cup.
Verify that the two‐wire path is connected to the controller, and that controller power is on.
The decoder will be powered over the two‐wire path, and the red and blue ICD‐HP leads will not be necessary.
Protect the ICD‐HP from sprinkler spray and other water sources!
Operations
Turn the programmer on with the power button. The logo will appear, and change to the Main Menu in a few seconds.
Main Menu & Navigation
For the first use, or to change general settings, select ICD‐HP Setup.
Most menu selections throughout ICD‐HP operate with the same buttons. Use the arrow keys to navigate around the
screens. Use the + and – buttons to change the choices in settings. Use the Next 3 button to select an option, and go to
the next screen. Use the Back 4 button to exit and return to the previous level.
In some selections, the Enter button  is used to make selections.
11
ICD‐HP Set‐up
LCD Settings: Adjust screen appearance with Contrast, Backlight, and Backlight Timeout controls. Use the arrow buttons
to move to the item you wish to change, and press the + or – buttons to adjust the settings.
Increasing the contrast and backlight can improve visibility in low light conditions, but will also consume batteries more
quickly. The backlight will turn off automatically after a period of no use. The time is selectable under Backlight Timeout
controls, or the backlight can be turned off to preserve battery life.
Set Languages: Select operating system language of your programmer.
Use the up/down arrow keys to set the pointer to your selection.
Use the Next 3 button to make the selection, and the display will show the selection.
Press the Back 4 button to exit.
Set Units of Measure: Change between English and Metric readings (GPM or LPM).
Use the up/down arrow keys to set the pointer to your selection.
Use the Next 3 button to make the selection, and the display will show the selection.
Press the Back 4 button to exit.
12
Current Dec Versions: Shows the current versions of decoder firmware loaded into ICD‐HP. If you flash update a
decoder’s operating system, this is the version that will be loaded.
Decoder Programming Menu
Install a decoder with either method in “Connecting to a Decoder” section.
DECODER PROGRAMMING
----------MENU--------Get Decoder Info
Program Decoder
Get Decoder Status
From the Main Menu, use the arrow keys to point to Decoder Programming,
and press the Next 3 button. The Decoder Programming Menu will appear.
Use the arrows to move the pointer to any function, and press Next 3 to select it.
Get Decoder Info will check the decoder and display its current settings. It will
not change any of the settings in the decoder. It can be used to identify the
station number(s) and other settings of any ICD or later decoder.
Dec Type shows if the decoder is a station decoder and the number of
stations, or Pump decoder, or Sensor decoder.
DECODER INFO
---------------------Dec Type:
2-Station
Output #:
Station #:
007
Serial #:
########
◄/►Change OUTPUT #
Press ? For More
DECODER INFO
---------------------Dec Type:
2-Station
Pwr Factor:
Inrush:
Serial #:
########
Version:
1.01.005
Press ? To Return
13
Output #: If the decoder is a multi‐station decoder, the display only shows the station address of one output at a time.
Each color‐coded pair of wires from the decoder is a different output.
Press the left and right arrow buttons to move through the different outputs, and view the station numbers for each
output.
Decoder Info screens multi‐page screens. Press the ? button for More. The second page will show the Power Factor,
Inrush setting, and Version of the decoder firmware. Press ? again to return to the first page.
Serial numbers are not used to address decoders, except in older Hunter decoder controllers (IDS, Genesis and VSX
“Viking” decoder systems). Serial numbers cannot be changed.
14
Program Decoder will enter the station addresses and other settings of the decoder.
Move the pointer with the arrow buttons at the Main Menu screen to
Program Decoder and press Next 3.
The ICD‐HP will check for a decoder. If successful, it will display the Type,
Power Factor, and Inrush information for the decoder after a few seconds.
Type: Press the + and – buttons to change the decoder type. It is possible to
change a station decoder to Pump, to assign it to one of the P/MV
(Pump/Master Valve) outputs for the controller. It is best to use a single‐
station decoder for a P/MV output. If a multi‐station decoder is set to Type
Pump, the other outputs can no longer be used, and will be wasted.
If the Type shown is “Sensor”, the ICD‐HP is reading a Sensor Decoder and the
Type cannot be changed.
Pwr Factor: Power Factor. Default setting is 2 and this is the recommended
setting. The Power Factor can be increased for certain high current
requirements (such as Pump Start Relays), but this can degrade performance
for other stations on the line. Change only when required.
PROGRAM A DECODER
---------------------Dec Type:
6-Station
Pwr Factor: 2
Inrush:
Press 3 To Continue
-PROGRAM A DECODER-Output 1:
Sta-027
Output 2:
Sta-000
Output 3:
Sta-000
Output 4:
Sta-000
Output 5:
Sta-000
Output 6:
Sta-000
Press 3 To Program
15
Inrush: This can change the inrush timing for the station or relay when first turning on. Default setting is 3, and this rarely
needs to be changed. Consult Hunter Technical Support before changing the Inrush value.
Press Next 3 to continue.
Assign Station Numbers: The next screen will show the station number assigned to each decoder output. The number of
outputs is based on the decoder’s size. A single station decoder (ICD‐100) will only show one output. A two‐station
decoder (ICD‐200) will show two output lines, etc.
Use the up and down arrows to move the pointer to each output. Use the number keys to type the controller station
number you wish to assign to each output. Or, use the + and – keys to raise
and lower the station numbers.
-PROGRAM A DECODER-Output 1:
Sta-001
If you have already assigned a station number to an output, using the + and –
Output 2:
Sta-002
buttons to change another output will skip over any station number that has
Duplicate
Sta-003
Duplicate
Sta-003
already been assigned.
Example: Output 1 is assigned Sta‐007. When setting Output 2, using the +/‐
buttons will skip 007 and move directly from 006 to 008.
If numbers are entered directly from the keypad, it may temporarily permit a
duplicate, but this will not be sent to the decoder. If a duplicate station
number is entered in a multi‐station decoder, and the Next 3 button is
16
Press 3 To Program
Flashing “Duplicate” shows duplicate station
numbers‐ change address before
programming.
pressed, the ICD‐HP will refuse to send the program until the duplicate numbers have been changed.
The outputs with duplicate numbers will flash “Duplicate”, alternating with the output numbers.
Pump: If the Type was changed to Pump (instead of a station decoder), only Output 1 will be shown. Use + and – to
change between P/MV‐1 and P/MV‐2. (P/MV = Pump/Master Valve).
Programming: When all settings are made, and outputs are numbered (see Important Notes section), press the Next 3
button to send the station numbers to the decoder.
The display will show “Programming…” for a short time. If successful, “Programming Complete” will appear after the
program has been sent.
Decoder comm failed: This message indicates that the programming was not successful. Most likely causes are the
connections, or the decoder power. Check power leads to the decoder, programming cup cable connections, and verify
there is power on the two‐wire path from the controller (if programming in line).
Turn Line Power Off, and Back On: After programming or re‐programming installed decoders, the two‐wire path power
must be turned off for 15 seconds, and then back on, for the programming to take effect in the field.
The station numbers will be in the decoder’s memory, but the power must be cycled (off/on) to take effect. You can turn
off power to the controller, or remove the ADM99 output module from the controller, and then plug it back in after 15
seconds.
17
Important Notes:
Outputs may be assigned from 000 to 500. Do not assign a station number higher than the capacity of your controller, or
it will not operate! (Example: ACC99D has 99 station capacity. Do not program a station number higher than 99). The ICD‐
HP does not know the capacity of your controller.
Reserved Stations: It is possible to assign “000” to a decoder output with the ICD‐HP. This output will not be used.
However, it may be programmed at a later date, to add a new station to a
multi‐station decoder.
-PROGRAM A DECODER-Output 1:
Sta-001
For example, a six‐station decoder could have output #6 (or any other
Output 2:
Sta-032
outputs) set to station 000. The 000 outputs would not be operational, but
Output 3:
Sta-025
could be reserved for future additions. Then the new station number could
Output 4:
Sta-081
Output
5:
Sta-014
be assigned to the reserved 000 output with the ICD‐HP.
Output 6:
Sta-000
Press
To
Program
Do not assign a station 000 unless you wish to skip a station, or reserve one
for future expansion. Station number 000 cannot be turned on by a
Sample ICD‐600 display with random station
controller!
numbers and Output 6 held in reserve (000).
Stations in Random Order: It is possible to assign any valid station numbers in any order. The ICD‐HP can enter any
station numbers in a multi‐station decoder in any order. This cannot be done from the controller’s decoder programming,
but is an added feature with ICD‐HP.
18
Do not assign duplicate addresses! No decoder controller should have duplicate station numbers, anywhere within the
entire system. (This does not apply to station 000, however.)
The ICD‐HP will not allow duplicate station numbers within a single decoder, but it cannot detect duplicates elsewhere in
the system.
Sensor Decoder Programming (ICD‐SEN)
If the decoder in the programming cup is an ICD‐SEN sensor decoder, only
the address can be set. The Type will be Sensor, and this cannot be
changed when a sensor decoder is found.
PROGRAM A DECODER
---------------------Dec Type:
Sensor
Address:
Choose an address between 1‐5 with the + or – buttons, and press Next 3
to send to the sensor decoder.
Turn Line Power Off, and Back On: After programming or re‐programming
installed decoders, the two‐wire path power must be turned off for 15 seconds, and then back on, for the programming
to take effect in the field.
Other Sensor Decoder set up options are made at the controller, and not from the ICD‐HP. Consult controller and/or
sensor decoder documentation for complete setup instructions.
Get Decoder Status
19
Connect to any decoder to view status, for identification and diagnostics. This can be used with either installed decoders,
or disconnected decoders that are powered through the ICD‐HP power leads.
From the Main Menu, select Decoder Programming with the Next 3 button. Move the pointer with the up/down arrows
to Get Decoder Status, and press Next 3 again to select. The ICD‐HP will attempt to communicate with the decoder.
When a decoder is found, the status will be displayed.
Station Decoders: If the decoder is a Station Output decoder, the display will
show the following information.
Dec State: Can be Normal, Fault, or Damaged.
Normal: Decoder is responding correctly.
Fault: Decoder output wires are shorted or solenoid coil is shorted.
This does not indicate a problem with the decoder! Check field
wiring and solenoid.
DECODER STATUS
---------------------Dec State:
Normal
Current:
167mA
Output #: 1 2 3 4 5 6
Solenoid: Y Y Y Y Y N
Active : Y Y Y Y N N
Normal Decoder has 5 solenoids detected,
with 4 stations running (Active).
Damaged: There is a problem with the decoder, and it should be replaced. Damaged indicates the decoder is
“leaking” voltage on the outputs when it should be off.
20
Decoder comm failed: This may indicate a complete decoder failure, OR the decoder may not be connected or
powered properly. Verify ALL connections: ICD‐HP to programming cup (both ends) and decoder power. If the
decoder is connected in the two‐wire path but the controller power is Off, decoder will not respond. If decoder
and ICD‐HP are connected correctly, and decoder has power, and Decoder comm failed message appears,
decoder is likely defective.
Current: Displays electrical current draw of decoder in milliamps. Standby range is approximately 3‐5ma. When decoder
is active, this value will be higher, depending on number and type of devices connected to decoder output. Total current
on a decoder cannot exceed 1000ma.
The current display does not change in real time. If a station is started or stopped, run the diagnostic Get Decoder Status
again to see the new current draw.
Output: The output matrix shows the status of each output of the decoder. The display will show the number of outputs
for the size of decoder detected (a single station decoder will only have 1 output).
Solenoid: Shows whether a solenoid or similar device is detected on the output (Y=Yes, N=No).
The Solenoid status may not change until power has been cycled off/on to the decoder, if a solenoid has just
been added to the decoder. Turn off either the controller, or remove the ADM99 decoder output module from
the controller, for approximately 15 seconds, and then turn the power back on (or replace the ADM99). Solenoid
status will be updated.
21
Active: Shows whether the output is currently turned on (Y=Yes, N=No).
Sensor Decoders: If the decoder found during Get Decoder Status is a Sensor Decoder, the display will show the status of
each sensor input to the decoder’s Ports, on individual screens.
Use the left and right arrows to see each Port (A and B) individually.
Clik sensors: The display will show the current state of the Clik input as
Closed (normal) or Open (alarmed).
Flow sensors: The display will show the type of flow sensor (set from the
controller), the size or K‐Factor and Offset, and the current actual flow in
GPM or LPM (depending on Unit of Measurement settings).
The ICD‐HP is not used to set or change flow sensor settings. It shows what
the controller has sent to the sensor decoder, and displays the current flow.
The flow sensor is always connected to Port A of the sensor decoder. Use
the left and right arrows to view Port B, which can be used for Clik sensor
inputs.
The flow reading will update changes in flow live, in the screen display, as
22
SENSOR STATUS #
---------------------Port A Type: Clik
State:
Closed
◄/► To Change Port
SENSOR STATUS #
---------------------Port A Type: FLOW
Sensor:
HFSFCT150
Flow Rate:
xxxx.x GPM
◄/► To Change Port
valves open and close.
Decoder Firmware
The decoder firmware menu checks, and has the ability to update, a decoder’s operating system (firmware).
From the Main Menu, use the up/down arrows to move the pointer to Decoder Firmware, and press Next 3. The display
will show two options, Get Decoder Ver and Update Dec Firmware.
Get Decoder Ver: Move the pointer to Get Decoder Ver and press Next 3. This will check the decoder, and display the
version number.
Update Dec Firmware: Move the pointer to Update Dec Firmware and press
Next 3. This will display the “Latest Version” loaded into the ICD‐HP, and
display it above the version found in the decoder. If the versions are different,
you have the option to load the latest version into the decoder.
Note: The “Latest Firmware Version” is loaded into the ICD‐HP operating
system. This can be updated, if new firmware is released, by re‐flashing the
ICD‐HP itself from a computer. The updates will contain both station decoder
and sensor decoder firmware versions for the decoders.
DECODER UPDATE
---------------------Latest Firmware Version:
#.##.###
Attached Decoder
Version:
#.##.###
Press 3 To Continue
23
If the version in the decoder is older than the version loaded into the ICD‐HP,
and you wish to update the decoder, press Next 3. This will show the version
of the “bootloader” program, which actually loads the firmware into the
decoder.
DECODER UPDATE
---------------------Update Progress...
Press Next 3 again to continue, and the firmware update will begin. A status
bar will show the progress of the download.
It will take several minutes to update a decoder’s firmware. Do not disconnect the decoder during this update! The
firmware update should always be allowed to complete, once it has begun.
The update will not erase the decoder output station addresses. If the decoder is used as a Pump, this information will
also be retained.
DECODER UPDATE
If the decoder is a Sensor Decoder, it will automatically receive the Sensor
---------------------!Complete!
Decoder firmware, and the address and port settings will be retained.
Dec Type:
X-Station
Station
#:
###
A status screen will announce when the update is complete, and verify the
Serial #:
########
new version number.
Version:
#.##.###
24
Diagnostics
The Diagnostics menu allows operation and test of decoder functions.
From the Main Menu, move the pointer to Diagnostics and press Next 3.
Turn Station On/Off: The ICD‐HP can turn individual station outputs on and
off for diagnostic purposes. This function only works with decoders wired into
the two‐wire path, and will not operate when powered by the leads from the
ICD‐HP!
TURN STATION ON/OFF
---------------------Output #:
Station #:
###
Serial #:
########
State:
xxx
◄/► To Change Output #
+ On / - Off
Connect a decoder with the programming cup. Move the pointer to the Turn
Station On/Off, and press Next 3.
The ICD‐HP will first connect to the decoder, and display the first station output. If the decoder is a multi‐station decoder,
use the left and right arrow buttons to move to the station to turn on or off.
Press + to turn a station on. The station will run for approximately 1 minute if running alone, or 12 minutes if another
station is running from the controller (see Important Note in this section). The State will change from Off to On after a
few seconds.
25
If the station is connected to a pressurized valve, the water will turn on. Take care to keep the ICD‐HP out of the water
from sprinklers.
Press ‐ to turn a station off. The station will turn off and the State will change from On to Off after a few seconds.
Important Note: The ICD‐HP cannot set a run time for a decoder activation. The ACC controller will send an Off command
down the two‐wire path once per minute, when no stations are supposed to be running. If you turn a station on with the
ICD‐HP, this controller command will turn that station back off, within a minute.
If longer run times are required for diagnostic purposes, turn another decoder station on from the ACC controller, or with
a remote control (ICR, ROAM, or Maintenance Radio). As long as this station is running from the controller, the “off “
command will not be sent every minute.
If another station is running from the controller as described, and a station in the field is turned on with the ICD‐HP, it will
run for approximately 12 minutes, or until it is turned off from the ICD‐HP.
Get Decoder Status: This allows quick access to the same status matrix for outputs as the Get Decoder Status command
from the Decoder Programming menu.
This can be used to view the current draw of a solenoid after it has been turned on with the Turn Station On/Off
command from the ICD‐HP. Turn the station or multiple stations on, then use Get Decoder Status to view the current
draw on the decoder.
26
Troubleshooting
PROBLEM
CAUSES
SOLUTIONS
ICD‐HP will not communicate
with decoder.
No power to decoder.
Check controller power to two‐wire
path, or connect power leads to
decoder.
Stations will not turn on.
Decoder Programming cup disconnected.
Batteries low.
Check battery display or retry with
USB power if available.
No solenoid connected.
Check solenoid connections.
Decoder is powered from ICD‐HP power
leads.
Check two‐wire path and controller
power.
27
No power on two‐wire path.
Master Valve not on (station solenoid is on,
but no water).
Start station with MV from controller
or remote.
Decoder will not respond after
firmware update.
Stuck in bootloader mode.
Repeat firmware update steps and
allow to complete.
Poor battery life.
Display backlight will reduce battery life.
Reduce timer or turn off backlight
display.
28
Specifications
Operating Specifications
Height: 8.25”/21cm
Station Number Range: 001 – 500 (blank outputs are set
to “000”)
Width: 3.875”/9.8cm
Depth: 2.1875”/5.5cm
Sensor Decoder Address Range: 001 ‐ 005
Dimensions, Programming Cup
Max Cable length to Programming Cup: 6ft/2m
Height: 2.375”/6cm
Max Range of Induction Signal: 2”/5cm from bottom of
programming cup.
Width: 2.375”/6cm
Electrical Specifications
Depth: 2.625”/6.6cm
Battery Power: 4 x AA batteries
Weight
Voltage Limit (red/blue leads): 60VAC, max
ICD‐HP only: 1.4lbs/.63 kg
Dimensions, ICD‐HP
Complete in Case: 4.8lbs/2.1kg
29
FCC Notice
FCC ID: M3UICDHP
This device complies with FCC rules Part 15. Operation is subject to the following two conditions:
•
•
This device may not cause harmful interference and
This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for class B digital devices, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation.
This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment on and off, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and the receiver
• Connect the equipment to an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
The user is cautioned that changes and modification made to the equipment without the approval of the manufacturer
could void the user’s authority to operate this equipment.
30
Industry Canada Notice
IC: 277A‐ICDHP
Operation is subject to the following two conditions:
This device may not cause harmful interference and
This device must accept any interference received, including interference that may cause undesired operation.
CE & AUSTRALIA NOTICE
Hunter Industries hereby declares that this remote control device is in compliance with the essential requirements and
other relevant provisions of Directive 1999/5/CE.
Declaration of Conformity: We, Hunter Industries Incorporated, 1940 Diamond Street, San Marcos, CA 92078, declare
under our own responsibility that the ICD Handheld Programmer, model ICD‐HP to which this declaration refers,
conforms with the relevant standards:
Emissions: ETSI EN 300 330‐2 V1.3.1
Immunity: ETSI EN 301 489‐1 V1.8.1
ETSI EN 300 330‐1 V1.3.1
ETSI EN 301 489‐3 V1.4.1
31

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Modify Date                     : 2009:05:21 15:15:27-07:00
Create Date                     : 2009:05:19 16:57:05-07:00
Author                          : kmanivone
Page Count                      : 31
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:cff72b38-4cb9-4a04-ae5d-f2ca740b2247
Producer                        : Acrobat Distiller 6.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Document ID                     : uuid:e90d6642-34fc-46e8-b1dd-155247050276
Format                          : application/pdf
Title                           : Microsoft Word - ICD-HP Owners Manual.doc
Creator                         : kmanivone
Page Mode                       : UseThumbs
EXIF Metadata provided by EXIF.tools
FCC ID Filing: M3UICDHP

Navigation menu