  Preface Welcome to the world of Hytera and thank you for purchasing this product. This manual includes a description of the functions and step-by-step procedures for use. To avoid bodily injury or property loss caused by incorrect operation, please carefully read the Safety Information Booklet before use.    This manual is applicable to the following product: RD106X Digital Repeater (X may represent 2, 5, 6 or 8)
  Copyright Information Hytera is the trademark or registered trademark of Hytera Communications Corporation Limited (the Company) in PRC and/or other countries or areas. The Company retains the ownership of its trademarks and product names. All other trademarks and/or product names that may be used in this manual are properties of their respective owners.   The product described in this manual may include the Company’s computer programs stored in memory or other media. Laws in PRC and/or other countries or areas protect the exclusive rights of the Company with respect to its computer programs. The purchase of this product shall not be deemed to grant, either directly or by implication, any rights to the purchaser regarding the Company’s computer programs. Any of the Company’s computer programs may not be copied, modified, distributed, decompiled, or reverse-engineered in any manner without the prior written consent of the Company. Disclaimer The Company endeavors to achieve the accuracy and completeness of this manual, but no warranty of accuracy or reliability is given. All the specifications and designs are subject to change without notice due to continuous technology development. No part of this manual may be copied, modified, translated, or distributed in any manner without the express written permission of us. We do not guarantee, for any particular purpose, the accuracy, validity, timeliness, legitimacy or completeness of the Third Party products and contents involved in this manual. If you have any suggestions or would like to learn more details, please visit our website at: http://www.hytera.com. RF Radiation Information This product must be restricted to operations in an Occupational/Controlled RF exposure Environments. Users must be fully aware of the hazards of the exposure and able to exercise control over their RF exposure to qualify for the higher exposure limits.   RF Radiation Profile Radio Frequency (RF) is a frequency of electromagnetic radiation in the range at which radio signals are transmitted. RF technology is widely used in communication, medicine, food processing and other fields. It may generate radiation during use.   RF Radiation Safety In order to ensure user health, experts from relevant industries including science, engineering, medicine and health work with international organizations to develop standards for safe exposure to RF radiation. These standards consist of:
    United States Federal Communications Commission, Code of Federal Regulations; 47 CFR § 1.1307, 1.1310 and 2.1091   American National Standards Institute (ANSI) / Institute of Electrical and Electronic Engineers (IEEE) C95. 1:2005; Canada RSS102 Issue 5 March 2015   Institute of Electrical and Electronic Engineers (IEEE) C95.1:2005 Edition  FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. Verification of harmful interference by this equipment to radio or television reception can be determined by turning it off and then on. The user is encouraged to try to correct the interference by one or more of the following measures:   Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver.   Connect the equipment into an outlet on a different circuit to that of the receiver's outlet.   Consult the dealer or an experienced radio/TV technician for help. Operation is subject to the following two conditions:     This device may not cause harmful interference.   This device must accept any interference received, including interference that may cause undesired operation. Note: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.   FCC Regulations Federal Communication Commission (FCC) requires that all radio communication products should meet the requirements set forth in the above standards before they can be marketed in the U.S, and the manufacturer shall post a RF label on the product to inform users of operational instructions, so as to enhance their occupational health against exposure to RF energy.   Operational Instructions and Training Guidelines   To ensure optimal performance and compliance with the occupational/controlled environment RF energy
  exposure limits in the above standards and guidelines, users should always adhere to the followings:     Gain of antenna must not exceed 10dBi (Outdoor) or 5dBi (Indoor).   Antenna Installation: install the antenna at least 150cm (Outdoor) or 85cm (Indoor) away from your body, in accordance with the requirements of the antenna manufacturer/supplier.  ISEDC Statement This device complies with Innovation, Science and Economic Development Canada Compliance license-exempt RSS standard(s). Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation.  Le présent appareil est conforme aux CNR d'ISEDC applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement  ISEDC Radiation Exposure Statement:   This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment.  This equipment should be installed and operated with minimum distance 150cm (Outdoor) or 85cm (Indoor) between the antenna & your body.  ISEDC exposition aux radiations:   Ce dispositif doit être limité aux opérations liées au travail dans un environnement d'exposition RF professionnel/contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 150cm (extérieur) or 85cm (intérieur) de distance entre le antenne et votre corps.
  EU Regulatory Conformance As certified by the qualified laboratory, the product is in compliance with the essential requirements and other relevant provisions of 2014/53/EU. Please note that the above information is applicable to EU countries only.
  Documentation Information Icon Conventions   Icon  Description   Indicates references that can further describe the related topics.   Indicates situations that could cause data loss or equipment damage. Notational Conventions Item  Description   Example Boldface Denotes menus, tabs, parameter names, window names, dialogue names, and hardware buttons.   To save the configuration, click Apply. The  Log Level Settings dialogue appears.  Press the PTT key. " " Denotes messages, directories, file names, folder names, and parameter values. The screen displays "Invalid Battery!". Open "PDT_PSS.exe". Go to "D:/opt/local". In the Port text box, enter "22". >  Directs you to access a multi-level menu.  Go to File > New. Italic  Denotes document titles. For details about using the DWS, refer to Dispatch Workstation User Guide. Courier New  Denotes commands and their execution results. To set the IP address, run the following command: vos-cmd - m name IP
  1. Packing List Please unpack carefully and check that you have received the following items. If any item is missing or damaged, please contact your dealer.   Item  Quantity (PCS)  Item  Quantity (PCS) Repeater 1  Documentation Kit 1 Power Cord  1  /  /     Figures in this manual are for reference only.    Check the main unit label to ensure that the purchased product is correct.
  2. Product Overview 2.1 Front Panel  No.  Part Name  No.  Part Name 1  Air Inlet for PA  8  Timeslot A RX Indicator   2  Channel Up Key  9  Timeslot A TX Indicator 3  Channel Down Key  10  Analog Mode Indicator 4  Seven-segment Display  11  Digital Mode Indicator 5  Alarm Indicator  12  Audio/Programming Connector 6  Timeslot B RX Indicator  13  Air Inlet for Power Supply 7  Timeslot B TX Indicator  /  / 2.2 Rear Panel  No.  Part Name  No.  Part Name 1  TX Antenna Connector    6  Ethernet Port 2 2  Monitor/Tuning Interface  7  DC Power Inlet 3  Accessory Jack  8  AC Power Inlet   4  RX Antenna Connector  9  AC Power Switch 5  Ethernet Port 1  10  Ground Screw
  2.3 Internal Parts  No.  Part Name  No.  Part Name 1  Power Supply Module    5  Wind Scooper 2 Network Board  6 Fan 3 Baseband Module  7 Control Panel 4  PA Module  8  Floating Charge Board
  3. Installation To ensure optimum performance and reliability of the repeater, install it properly according to the following instructions.  3.1 Installation Requirements Installation Environment The repeater must be installed in a dry and well-ventilated place. The ambient temperature ranges from -30°C to +60°C, and the relative humidity is 95%.   Installation Location The repeater can be installed in a rack, bracket and cabinet or on a desk.    For more information, refer to the Safety Information Booklet.  3.2 Pre-installation Tasks Preparing the tools  Phillips screwdriver    T-10 torx screwdriver  Spanner  Anti-static gloves  Multimeter  Checking the power supply Before installing the repeater, make sure that the power supply meets the following requirements:   DC power voltage: 13.6±15% V   AC power voltage: 100~240V 3.3 Installation Procedure To install the repeater, do as follows:
  1.   Wear the anti-static gloves.   2.   Place the repeater to a proper location.   3.   Connect accessories including the antenna, feed lines, and power cords to the repeater.    The antenna and feed lines need to be purchased separately. 4.   Ground the repeater through the Ground Screw located on the rear panel.   3.4 Post-installation Check To check whether the repeater works properly, do as follows: 1.  Turn the repeater on. 2.  Observe the LED indicators and the display in the front panel.   If the Timeslot A RX indicator glows yellow and the display shows the current channel, the repeater works properly.   If the Alarm Indicator glows red and the display shows the alarm code, the repeater does not work properly.
  4. Basic Operations 4.1 Turning the Repeater On or Off If the repeater is connected to a DC power supply, press the power switch on the DC power supply to turn the repeater on or off. If the repeater is connected to an AC power supply, press the AC Power Switch located in the rear panel to turn the repeater on or off.  Do not touch the metal on the side of the repeater for more than 1 second during normal use. 4.2 Switching the Channel You can use the Channel Up or Channel Down key in the front panel to change the channel. After you change the channel, the current channel number appears on the display of the repeater. To switch to the previous or next channel, press the Channel Up or Channel Down key. 4.3 Checking LED Indications Indicator  Color  Description  Digital Mode    Blue  The repeater is operating in digital mode.   Analog Mode    Yellow  The repeater is operating in analog mode.   Alarm    Red  The repeater is not working properly. Timeslot A TX      Red   Analog mode: The repeater is transmitting.   Digital mode: The repeater is transmitting in timeslot A. Timeslot A RX    Green   Analog mode: The repeater is receiving.     Digital mode: The repeater is receiving in timeslot A.   Timeslot B TX    Red  Digital mode: The repeater is transmitting in timeslot B.  Timeslot B RX    Green  Digital mode: The repeater is receiving in timeslot B.
  5. Alarm Information With the Alarm feature enabled by your dealer, the repeater can detect alarms. When an error occurs, the display shows the alarm code with the Alarm Indicator on the front panel glowing red.   5.1 Low Forward Power Alarm Description When the forward power is below the preset value, the Alarm Indicator glows red and the display shows the alarm code E8. Then the repeater may continue or stop the transmission. Solution Check if the connection between the repeater and RF adapter cable or antenna/feed line is loose or damaged.    If yes, secure or replace the cable or antenna/feed line.     If no, contact your local dealer for technical support.   5.2 TX/RX Unlock Alarm Description When the TX PLL or RX PLL is unlocked, the Alarm Indicator glows red and the display shows the alarm code E4 or E5 respectively.   Then certain features of the repeater become unavailable automatically.   Solution Disconnect the power supply, and then open the housing to check if the hardware cable is loose or damaged.   If yes, secure or replace the cable.     If no, contact your local dealer for technical support.
  5.3 Over Temperature Alarm Description When the temperature of the PA module exceeds the upper threshold, the Alarm Indicator glows red and the display shows the alarm code E6.   Then the repeater will stop transmission. Solution 1.   Check whether the temperature of the PA module surface is over 120 C.    If yes, proceed with Step 2.    If no, proceed with Step 3.    Do not touch the surface of the PA module to avoid burn. You can use a digital thermometerwith thermocouple to measure the temperature.   2.   Check whether the ambient temperature and ventilation conditions of the repeater satisfy the foregoing installation requirements.    If yes, proceed with Step 3.    If no, make improvements as soon as possible by mounting air conditioning equipment, improving equipment ventilation, or reducing ambient temperature.   3.   Check if the connection between the repeater and RF cable or antenna/feed line is loose or damaged.    If yes, secure or replace the cable or antenna/feed line.    If no, contact your local dealer for technical support.   5.4 Over/Low Voltage Alarm Description When the repeater detects that the voltage inputted by the external power supply is out of the normal range (11.56–15.64 V), the Alarm Indicator glows red and the display shows the alarm code EH (over voltage) or E3 (low voltage).   Then the repeater will automatically stop working.
  Solution 1.   Use voltmeter to check whether the DC or AC power voltage is too low or too high.    If yes, replace the DC or AC power supply.    If no, proceed with Step 2.   2.   Check whether the power cord is loose or damaged.    If yes, secure or replace the power cord.    If no, contact your local dealer for technical support.   5.5 Voltage Standing Wave Ratio (VSWR) Alarm   Description When the repeater detects the VSWR of the TX antenna for the PA module exceeds the normal value, the Alarm Indicator glows red and the display shows the alarm code E7.   Then the repeater will automatically work at low TX power.   Solution 1.   Check if the TX frequency is within the frequency range of the antenna.        If yes, proceed with Step 2.    If no, contact your local dealer to replace the antenna.   2.  Check if the connection between the repeater and RF adapter cable or antenna/feed line is loose or damaged.   If yes, replace the cable or antenna/feed line.    If no, contact your local dealer for technical support.
  6. Troubleshooting Phenomena  Analysis  Solution Power-on Failure The power cord may be unconnected or not securely connected to the outlet.   Properly connect the power cord and ensure secure connection.   The fuse in the power cord may be damaged.  Check if the fuse has blown. If yes, replace it with a new one.   Group members cannot talk to each other, or the repeater cannot communicate with a radio.   The TX/RX frequency of the repeater is inconsistent with that of the radio.   Check if the frequencies are consistent. Reset them when necessary.  The repeater fails to transit useful signal due to strong interference signal.  Remove or bypass the interference source, or change to operate at other frequencies.  The group member is out of the coverage of the repeater.   Go within the coverage of the repeater.  Group members cannot talk to each other, even though RX indication is given.  The radio ID is inconsistent with that of the other group members.   Set the radio ID to the same as that of the other members.   The CTCSS/CDCSS of the radio is inconsistent with that of the repeater.   Check if the CTCSS/CDCSSs are consistent, Reset the CTCSS/CDCSSs when necessary. Short communication range or poor audio. The connection cable is damaged, and the signal energy leaks.   Check the damages, and replace the cable with a new one if necessary.   The antenna connector and the cable may get loose connection or even disconnected. Check and secure the cable connector, or replace it if necessary. Invisible damage may occur to the cable.    Replace the cable with a new one.   If the above solutions cannot fix your problems, or you may have some other queries, please contact us or your local dealer for more technical support.
  7. Care and Cleaning To guarantee optimum performance as well as a long service life of the product, please follow the tips below. 7.1 Product Care   Keep the product at a place of good ventilation and heat dissipation to facilitate normal work.     Do not place irrelevant articles on top of the product to ensure optimal heat dissipation.     Do not pierce or scrape the product.   Keep the product away from substances that can corrode the circuitry.   Do not place the product in corrosive agents, solutions or water.   7.2 Product Cleaning  Be sure to power off the product before cleaning.     Remove the dust and fine particles on the repeater surface with a clean and dry lint-free cloth or a brush regularly.     Use a non-woven fabric with neutral cleanser to clean the keys, control knobs, LCD and connectors after long-time use. Do not use chemical preparations such as stain removers, alcohol, sprays or oil preparations.    Make sure the product is completely dry before use.
  8. Optional Accessories  Use the accessories specified by the Company only. If not, Hytera shall not be liable for any losses or damages arising out of use of unauthorized accessories.   For more information of the main optional accessories for the repeater, please consult your local dealer.